AMC 403RD

HARDSTAND

E E

X

SB-2

E A

V E

ACCESS ROAD - 3

A

T

T

T

T

T

T

CI

CI

CI

CI

S

SEE NOTE No. 1

LIGHTING CONTACTOR

H

H

G E

N

L S

L S -1

EXST GENERATOR

ELEC. HANDHOLE(TYP. OF 2EA)

SEE NOTE No. 2

IDS SYSTEM PANEL(GFGI, TYP.)

NOTES

SEE NOTE NO.3

3PH 4W 208Y/20V

EXST PNLBRD "LS1-1"

AND IDS SYSTEM POWER EACH.

3. PROVIDE NEW CKT BRK #7, 8 WITH 20A FOR SECURITY LIGHTING POWER

U/G 3-#10 AWG + 1-#10(G) IN 21mm PVC (TYP.)

TO CKT #7 OF "LS1-1"

TO CKT #7, 8 OF "LS1-1"

OF IDS SYSTEM PANELS. ALL IDS SYSTEM SHOULD BE PROVIDED BY ADVANTOR AS GFGI

2. THE CONTRACTOR SHOULD COORDINATE WITH ADVANTOR FOR EXACT LOCATION

PEDESTRIAN GATE SLIDING GATE

ABOVE GROUND SEE DWG.CD101

2-#10 AWG + 1-#10(G) IN 21mmC (TYP.)

SEE DETAIL DWG. ES503

1PH 120VAC 60Hz

(TYP. OF 20EA)

1/53W LED TYPE "NS-PL"

SECURITY LIGHTING POLE W/

SLIDING GATE AREA. SEE NOTE.4

U/G 2-#10 AWG + 1-#10(G) IN 21mmC (TYP.)

DIRECT TO THE NORTH SKY.(TYP.)

W/PHOTOCELL 1P-120VAC 1KW(MAX.)

ELEC. HELD TYPE. NEMA 4X(SST) ENCL.

PAD LOCKING PROVISION.

SOLID NEUTRAL, GND LUGS &

COIL-1PH 120VAC, W/A-O-M SEL. SW,

CIRCUIT BREAKER TYPE. 2P 30A 600VAC

1. COMBINATION LIGHTING CONTACTOR "LC"

S O

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

®of Engineers

US Army Corps

%PRODUCTION DATA 4%%PRODUCTION DATA 3%%PRODUCTION DATA 2%

%PRODUCTION DATA 1%

A N

S I

D

F

R E

A S

T D

IS

T R

IC

T

S E

O U

L ,K

O R

E A

U S

A E

D F

E ,E

D ,D

E S

IG

N B

R A

N C

H

IN

-H

O U

E

B p o fp w a d m in

A E

C S h e e tS e e d .d g n

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

U S

A G H

U M

P H

R E

Y S

K O

R E

A

GFGI

OF IDS SYSTEM PANELS. ALL IDS SYSTEM SHOULD BE PROVIDED BY ADVANTOR AS

2. THE CONTRACTOR SHOULD COORDINATE WITH ADVANTOR FOR EXACT LOCATION

DIRECT TO THE NORTH SKY.(TYP.)

W/PHOTOCELL 1P-120VAC 1KW(MAX.)

ELEC. HELD TYPE. NEMA 4X(SST) ENCL.

PAD LOCKING PROVISION.

SOLID NEUTRAL, GND LUGS &

COIL-1PH 120VAC, W/A-O-M SEL. SW,

CIRCUIT BREAKER TYPE. 2P 30A 600VAC

1. COMBINATION LIGHTING CONTACTOR "LC"

NOTES

AND PNLBRD "LS1-1"

AND IDS SYSTEM POWER EACH. PROVIDE LOCKING DEVICE TO CKT BRK #7, 8

3. PROVIDE NEW CKT BRK #7, 8 WITH 20A FOR SECURITY LIGHTING POWER

S P

T W

A R

E H

O U

S E A

R E

A

S E

C U

R

IT

Y F

E N

C E

ES101

EXTERIOR ELEC. POWER DISTRIBUTION PLAN

1:200 10000mm5000mm0mm

E X

T E

R

IO

R E

L E

C P

O W

E R D

IS

T R

IB

U T

IO

N P

L

BETWEEN U/G ELEC. & COMM. CONDUIT

4. THE CONTRACTOR SHOULD SEPARATE FOR RUNNING

AMC 403RD

HARDSTAND HARDSTAND

BLDG A

FIRE PUMP J

FNSH FL EL 8.65

O N

L Y

V E

H

IC

L E

C A

R P

O O

L

L Y

V E

H

IC

L E

C A

R P

O

L Y

V E

H

IC

L E

C A

R P

O

V

H

IC

L E

E F F

IC

IE

N T

F U

E L

E M

IS

S

IO

N

L O

W

V E

H

IC

L E

E F F

IC

IE

N T

F U

E L

E M

IS

S

IO

N

L O

W

V E

H

IC

L E

E F F

IC

IE

N T

F U

E L

E M

IS

S

IO

N

L O

W

V E

H

IC

L E

E F F

IC

IE

N T

F U

E L

E M

IS

S

IO

N

L O

W

O N

L Y

V E

H

IC

L E

C A

R P

O

(F-95064)

HARDSTAND A

COVERED

1st SIGNAL

BLDG H

FNSH FL EL 7.50

DN

UP UP

DNDN

DN

DN

DN

DN

DN DN

C

C

PTZ

1B

C

C

C

J

1st ST. 1st ST.

E A

V E

ACCESS ROAD - 3

A

A

T

T

T

TT

T

T

T

T

T T

T

T T

T

T

T

C I

C I

CI

CI

CI

CI

CI

C I

C I

C I

C I

C I

C I

C I

C I

C I

C I

C I

C I

C I

C I

CI

CI

CI

CI

CI

SSS

S

S S

T

B

TSB230

T

T

S O

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

®of Engineers

US Army Corps

SEE NOTE No. 1

IDS SYSTEM PANEL(GFGI, TYP.)

NOTES

MH3014

MH3015

C

C

C x

Cx

Cx

Cx C

GATES

PEDESTRIAN

SLIDING GATES

30ft WIDE

BLDG A

HARDSTAND

SPT060-4

EXTERIOR COMMUNICATION PLAN

1:500 25000mm12500mm0mm

OF IDS SYSTEM PANELS. ALL IDS SYSTEM SHOULD BE PROVIDED BY ADVANTOR AS GFGI

1. THE CONTRACTOR SHOULD COORDINATE WITH ADVANTOR FOR EXACT LOCATION

CMH3305

C x

No. 127-132( TYP.)

TO WARRIOR SUPPORT FOC 6

6CORE FOC SPLICING POINT

MAIN COMM ROOM

IN EXST 1WAY-103mmC COMM. DUCT W/ EXST FABRIC MESH (TYP.)

FROM COMM ROOM 232 OF WHARE HOUSE TO MH3015 VIA MH3014

ADD 1EA-12STRAND SM FOC IN EXST 1CELL

IN EXST 1WAY-103mmC COMM. DUCT W/ EXST FABRIC MESH (TYP.)

FROM COMM ROOM 232 OF WHARE HOUSE TO MH3015 VIA MH3014

ADD 1EA-12STRAND SM FOC IN EXST 1CELL

VIA MH3014, 3015(TYP.)

FROM MH3305 TO COMM ROOM 232 OF WAREHOUSE

IN EXST 1WAY-103mmC COMM. DUCT W/ EXST FABRIC MESH

ADD 1EA-6STRAND SM FOC

VIA MH3014, 3015(TYP.)

FROM MH3305 TO COMM ROOM 232 OF WAREHOUSE

IN EXST 1WAY-103mmC COMM. DUCT W/ EXST FABRIC MESH

ADD 1EA-6STRAND SM FOC

C x

C

EXST MANHOLE "M1"

FACILITY

WEATHER FORECAST

FROM MH3015 TO M1(TYP.)

IN EXST 1WAY-103mmC COMM. DUCT W/ EXST FABRIC MESH

ADD 1EA-12STRAND SM FOC

FROM M1 TO FIBER OPTIC SENSOR PANEL(IDS)

2WAY-103mmC W/ FABRIC MESH 2EA-3CELL FOR SPARE

& 5EA CELLS FOR THE SPARE(TYP.)

1EA-12STRAND SM FOC

NEW 3WAY-103mmC COMM. DUCT W/ NEW FABRIC MESH 2EA-3CELL

"#B-2"

EXST PMS

S O

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

®of Engineers

US Army Corps

S

R E

A S

T D

IS

T R

IC

T

S E

O U

L ,K

O R

E A

U S

A E

D F

E ,E

D ,D

E S

IG

N B

R A

N C

H

IN

-H

O U

B p o fp w a d m in

A E

C S h e e tS e e d .d g n

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

U S

A G H

U M

P H

R E

Y S

K O

R E

A

S P

T W

A R

E H

O U

S E A

R E

A

S E

C U

R

IT

Y F

E N

C E

TS101

E X

T E

R

IO

R C

O M

M U

N

IC

A T

IO

N P

L

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

®of Engineers

US Army Corps

-1.0 +1.5

Rubber Cap

OPEN LOCK

O

P E

N

L O

C K

O P

E N

L O C

K

HOLE

LIFTING

STEEL FRAME

,1

0,2 0,2

1, (1/4")

EXPANSION SHIELDS

130mm

6mm

(5")

INSULATOR

FASTEN BY MEANS OF

RADIUS PORCELAIN

(1/2") BOLTS AND

54mm(2-1/8")

"A"

ELECTRICAL / TEL. HANDHOLE AND APPURTENANCE DETAILS

"A"

A

A

NOTES ( FOR HANDHOLE)

P L A N

NOTES

A-A SECTION VIEW

STEEL COVER

TELECOMMUNICATION OR ELECTRICAL

IN LETTER BLOCKS

(2-1/4")

55mm m m

64mm(2-1/2")x13mm

(1 -1 /2

(FOR ELECTRICAL) (FOR TEL CABLE)

CABLE RACK

(2-1/4")

55mm

FASTEN BY MEANS OF

64mm(2-1/2")x13mm

(1/2") BOLTS AND

25mm(1")

EXPANSION SHIELDS

(2-1/4")

55mm m m

PULLING-IN IRON

(1 -1 /2

T O P

MIN. OPENING

SECTION A - A'

1 NOT TO SCALE

130mm

(1/4")

(5")

915mm(36")

6mm

(3")

(9")

76mm

SOLDERED JOINT

230mm

SUMP

SLOPE TO DRAIN

END BELLS

21mm

(7/8")

COPPER FLASHING

25mm(1")

50mm(2")

DUCT WINDOW SEALING

WIDE SHEET

DUCT

GROUT

EMBEDMENT

EDGE OF

DUCT WINDOW

CORNERS & INTERSECTIONS

3. WALL & FLOOR;---MIN. 8" CENTERS W/12" HOOK AT

4. REINFORCING BARS,------NO. 4 ROUND DEFORMED

A MIN 4" SPACING BETWEEN BARS.

5. AS SHOWN AT A MIN 2" FOR OPENING AND WITH

(TYPICAL)

#4 AWG "BC"

GROUND WIRE

SUMP WALL AND FLOOR--------4'

WALL, TOP AND FLOOR---------6"

1. THICKNESS OF CONCRETE;

2. REINFORCING BARS,------NO. 4 ROUND DEFORMED

SEE SPEC.33 71 02

GROUND ROD

SEE SPEC.33 71 02

GROUND ROD

GALVANIZED.

2. ALL STEEL HARDWARES TO BE HOT DIPPED

SEE DWG. E-001,E-002

1. FOR ABBREVIATION, LEGEND AND GENERAL NOTES,

1/2 INCH ABOVE THE FINISHED GRADE.

AREAS THE TOP OF HANDHOLE COVER SHALL BE APPROX

THE FINISHED SURFACE OF THE PAVING. IN UNPAVED

6. THE TOP OF HANDHOLE COVER SHALL BE FLUSH WITH

ELECTRICAL FOR POWER, TELECOMMUNICATION FOR COMM.

7. THE NAME ON MANHOLE COVER SHALL HAVE ITS UTILITY NAME ;

G

AND FRAME

SUMP COVER

(TYP.)

CABLE RACK

IRON (TYP.)

PULLING-IN

4 MIN.

CABLE RACKS

ENTRANCE

EACH DUCT

OPPOSITE

IRON ONE

PULLING-IN

IRON

PULLING-IN

G

& QTY AS REQ'D

CONDUIT SIZE

(TYPICAL)

#4 AWG "BC"

GROUND WIRE

G

G

G approved equal

3. HANGUG CASTING/awp agent (model : HCF-041) or

- pad locking device system

- solid lid

- watertight frame

2. Inner lid shall be required as follow

- locking device system

- loading : 40,000 pound plus 30%

1. Manhole Cover are requirements as follow

S

R E

A S

T D

IS

T R

IC

T

S E

O U

L ,K

O R

E A

U S

A E

D F

E ,E

D ,D

E S

IG

N B

R A

N C

H

IN

-H

O U

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

ES501

E L E

C T

R

IC

A L D

E T

A

IL

S -1 j1 e d d c s p

P A

K .C

S

D A

L T

O N .N

G O

C -A

N H

A N .K

Y

C A

Y W

O O

D .C

H R

IS

W

U S

A G H

U M

P H

R E

Y S

K O

R E

A

S T P W

A R

E H

O U

S E A

R E

A

S E

C U

R

IT

Y F

E N

C E

A u g u s t2

E S

X X

X .d g n

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

®of Engineers

US Army Corps

WIDTH VARIES

CONCRETE

103mm103mm m m

4-WAY DUCT (TRAFFIC AREA)

76mm

76mm m m

76mm 76mm51mm51mm

3-WAY DUCT (TRAFFIC AREA)

m m

76mm

WIDTH VARIES

CONCRETE

103mm

76mm

76mm

103mm 103mm 103mm

CONCRETE

m m m m

4-WAY DUCT (NON-TRAFFIC AREA)

WIDTH VARIES

50mm1 m m m m

50mm

1-WAY DUCT (NON-TRAFFIC)

m m m m m m

2-WAY DUCT (NON-TRAFFIC AREA)

76mm

WIDTH VARIES

3-WAY DUCT (NON-TRAFFIC AREA)

WIDTH VARIES

50mm

2-WAY DUCT (TRAFFIC AREA)

m m

50mm

WIDTH VARIES

76mm m m

9-WAY DUCT (NON-TRAFFIC AREA)

m m

WIDTH VARIES

m m

76mm

471mm

76mm169mm

DUCT SPACER

169mm

WIDTH VARIES

m m m m m m

76mm m m m m m m m m

50mm 50mm

5-WAY DUCT (NON-TRAFFIC AREA)

50mm 50mm

76mm

76mm

76mm

DUCT SPACER

76mm

76mm50mm

DUCT SPACER

76mm

COMPACTED BACKFILL

WARNING TAPE

WIDTH VARIES

m m m m m m

GRADE

FINISHED

CUSHION

SAND

BACKFILL

COMPACTED

AS REQUIRED)

(SIZE & QUANTITY

PVC CONDUIT

(SIZE AS REQ'D)

PVC CONDUIT

REQUIRED)

(SIZE AS

PVC CONDUIT

TAPE

WARNING

BACKFILL

COMPACTED

CUSHION

SAND

GRADE

FINISHED

SIZE AS REQUIRED

PVC CONDUIT (TYP)

TAPE

WARNING

BACKFILL

COMPACTED

TRACER WIRE

#12 AWG INSULATED

CUSHION

SAND

ENCASEMENT

CONCRETE

TRACER WIRE

#12 AWG INSULATED

AS REQUIRED)

(SIZE & QUANTITY

PVC CONDUIT

BACKFILL

COMPACTED

TAPE

WARNING

BACKFILL

COMPACTED

CUSHION

SAND

TRACER WIRE

#12 AWG INSULATED

ENCASEMENT

CONCRETE

TAPE

WARNING

AS REQUIRED)

(SIZE & QUANTITY

PVC CONDUIT

TRACER WIRE

#12 AWG INSULATED

TAPE

WARNING

TRACER WIRE

#12 AWG INSULATED

CUSHION

SAND

TRACER WIRE

#12 AWG INSULATED

GRADE

FINISHED

TRACER WIRE

#12 AWG INSULATED

SIZE AS REQUIRED

PVC CONDUIT (TYP)

CUSHION

SAND

TRACER WIRE

#12 AWG INSULATED

AS REQUIRED)

(SIZE & QUANTITY

PVC CONDUIT

TAPE

WARNING

BACKFILL

COMPACTED

AS REQUIRED)

(SIZE & QUANTITY

PVC CONDUIT

ENCASEMENT

CONCRETE

CUSHION

SAND

AS REQUIRED)

(SIZE & QUANTITY

PVC CONDUIT

BACKFILL

COMPACTED

TAPE

WARNING

CUSHION

SAND

TRACER WIRE

#12 AWG INSULATED

CUSHION

SAND

TAPE

WARNING

BACKFILL

COMPACTED

S

R E

A S

T D

IS

T R

IC

T

S E

O U

L ,K

O R

E A

U S

A E

D F

E ,E

D ,D

E S

IG

N B

R A

N C

H

IN

-H

O U

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

ES502

E L E

C T

R

IC

A L D

E T

A

IL

S -2 j1 e d d c s p

P A

K .C

S

D A

L T

O N .N

G O

C -A

N H

A N .K

Y

C A

Y W

O O

D .C

H R

IS

W

U S

A G H

U M

P H

R E

Y S

K O

R E

A

S T P W

A R

E H

O U

S E A

R E

A

S E

C U

R

IT

Y F

E N

C E

E S

X X

X .d g n

A u g u s t

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

®of Engineers

US Army Corps

NOTES

PARKING & STREET LIGHT DETAIL(NS-PL)

STUBBED OUT 103mm

(TYP.)

POLE (TYP.)

ANCHOR BOLT

19mm DIA.x 406mm LONG

762mm x 762

762mm SQ.

NOT TO SCALE

POLE FOUNDATION DETAIL

PVC CONDUIT

TO OTHER LIGHT

G.L.

BASE PLATE

PEDESTAL W/ 8-#6 VERTICAL BARS

& #3 TIES @ 254 mm

100mm m m

#6,"BC"

G m m

#6"BC"GROUND WIRE

GROUND LUG AND

4000 PSI IN 28 DAY

CONCRETE

SEE SPEC.

GROUND ROD,

DOOR OPENING

FOR LIGHTING JUNCTION BOX

SIZE AS REQUIRED(TYP)

BASE BOLT COVER

COUPLING(TYP.)

GALVANIZED.

1. ALL POLE HARDWARES TO BE HOT DIPPED

,0

-AMBIENT TEMPERATURE : -40 ~ 40 Degrees

-LED & OPTICAL ASSEMBLY TYPE : OPTIMIZED LED ARRAY

BASED ON DISTRIBUTION PATTERN

-3ME - ASYMMETRIC TYPE

-DIMENSION : W635 * L482 * H122 (mm)

FEATURES

GENERAL DESCRIPTION

-COLOR TEMPERATURE & CRI : 5700K & 70RA

-FINISH : Corrosion Resistant Ultra-Durable Powder Painting

-MATERIAL : DIE-CAST Aluminum

-MOUNTING : POLE

-RATINGS : Enclosure rated IP66 per IEC 60529

-LIFE TIME : 100,000 Hours @ L70

-NET WEIGHT & EPA : 12KG & 0.14 SQ M MAX

BASE PLATE DETAILHAND HOLE DETAIL

4-30X70L SLOT HOLE

2. LED LIGHT SHALL COMPLY WITH LM-79 & LM-80 TEST

AND SHALL BE UL LISTED.

1. LED CONVERTOR SHALL COMPLY WITH UL 8750, UL935

NOTE.

-PROFILE : LED OUTDOOR STREET LIGHTING FIXTURE

25.0"(635mm)

8.1"(206mm)

.1 m m

.8 m m

.8 m m

.0 m m

POLE TEMPLATE DETAILARM DETAIL

Hole 2 Required

0.344" (9mm)

Hole

0.5" (13mm)

(5 m m

(5 m m

(2 m m

25.0"(635mm)

8.1"(206mm)

.1 m m

.8 m m

.8 m m

.0 m m

Backing Plate

Pole Mount Adapter

Backing Plate

5/16" Hex Nut Pole

Foam Gasket

Pole Mount Adapter

Pole

-POWER SUPPLY : UNI Volt 277V AC

BOTTOM-180mm DIA

POLE SHAFT SIZE(7m) :TOP-90mm DIA

STKT590(ATOS60) 3.2mmTHICK

TAPERD AND ROUND

HOT DIP GALVANIZED STEEL POLE

(SUBSTITUTE THE METAL HALIDE LAMP 250W)

-TYPICAL INITIAL LUMEN : *53W(3ME TYPE) - 7,113LM

S

R E

A S

T D

IS

T R

IC

T

S E

O U

L ,K

O R

E A

U S

A E

D F

E ,E

D ,D

E S

IG

N B

R A

N C

H

IN

-H

O U

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

ES503

E L E

C T

R

IC

A L D

E T

A

IL

S -3 j1 e d d c s p

P A

K .C

S

D A

L T

O N .N

G O

C -A

N H

A N .K

Y

C A

Y W

O O

D .C

H R

IS

W

U S

A G H

U M

P H

R E

Y S

K O

R E

A

S T P W

A R

E H

O U

S E A

R E

A

S E

C U

R

IT

Y F

E N

C E

A u g u s t

E S

X X

X .d g n

Subject to change w ithout notice

PH

(763) 422-2211 • FX (763) 422-2600 • hoffm anonline.com

2010 Pentair Technical Products

Stainless Steel: W all-M ount Enclosures

W all-M ount Enclosures and A ccessories

Spec-00090 F

Spec-00090

FPH (763) 422-2211

FX (763) 422-2600

Stainless Steel W all-M ount Enclosures

W all-M ount Enclosures and A ccessories

Continuous H inge w ith 3-Point Latch, Type 4X

Industry Standards

U L 508A

Listed; Type 3R, 4, 4X, 12; File N

o. E61997 cU L Listed per CSA

C22.2 N o 94; Type 3R, 4, 4X, 12; File N o.

E61997

N

EM

A

/EEM

AC Type 3R, 4, 4X, 12, 13

IEC 60529, IP66

M eets N

EM

A Type 3RX requirem ents

A pplication

These enclosures feature H offm an’s exclusive PO W

ERG

LID

E® H andle w ith 3-point latching, ideal for indoor or outdoor applications that require corrosion protection, convenient access, and padlocking security.

Specifications

14 gauge Type 304 or 316L stainless steel bodies and doors

Seam s continuously w elded and ground sm ooth

Seam less foam -in-place gasket

Rolled lip around three sides of door

Internal 3-point latch and Type 316L stainless steel padlocking

PO

W

ERG

LID

E H andle

Rem ove door by pulling stainless steel continuous hinge pin

D ata pocket is high-im pact therm oplastic

Collar studs provided for m ounting optional panels

Exterior hardw are on Type 316L stainless steel enclosures m atches enclosure m aterial

Bonding provision on door; grounding stud on body

Finish D oor, sides, top and bottom have sm ooth #4 brushed finish. H andle is electropolished.

A ccessories

See also Accessories.

Panels for Type 3R, 4, 4X, 12 and 13 Enclosures Steel and Stainless Steel W indow Kits

H 2O

M IT ® Vent D rains, Type 4X H

2O M

IT ® Therm oelectric D ehum idifier

M odification and Custom ization H offm an excels at m odifying and custom izing products to your specifications. Contact your local H offm an sales offi ce or distributor for com plete inform ation.

Bulletin: A

4SW

Standard Product

Catalog Num ber

AxBxC in./m m

Stainless Steel Type

F in./m

Steel Panel

Conductive Panel

Stainless Steel Panel

Panel Size D x E in./m

Data Pocket

A24H2006SSLP3PT

24.00 x 20.00 x 6.00 610 x 508 x 152

3.00

A24P20 A24P20G

A24P20SS6

21.00 x 17.00 533 x 432

Sm all

A24H2006SS6LP3PT

24.00 x 20.00 x 6.00 610 x 508 x 152

316L 3.00

A24P20 A24P20G

A24P20SS6

21.00 x 17.00 533 x 432

Sm all

A24H2008SSLP3PT

24.00 x 20.00 x 8.00 610 x 508 x 203

3.00

A24P20 A24P20G

A24P20SS6

21.00 x 17.00 533 x 432

Sm all

A24H2008SS6LP3PT

24.00 x 20.00 x 8.00 610 x 508 x 203

316L 3.00

A24P20 A24P20G

A24P20SS6

21.00 x 17.00 533 x 432

Sm all

A24H2408SSLP3PT

24.00 x 24.00 x 8.00 610 x 610 x 203

3.00

A24P24 A24P24G

A24P24SS6

21.00 x 21.00 533 x 533

Sm all

A24H2408SS6LP3PT

24.00 x 24.00 x 8.00 610 x 610 x 203

316L 3.00

A24P24 A24P24G

A24P24SS6

21.00 x 21.00 533 x 533

Sm all

A30H2408SSLP3PT

30.00 x 24.00 x 8.00 762 x 610 x 203

3.00

A30P24 A30P24G

A30P24SS6

27.00 x 21.00 686 x 533

Large

A30H2408SS6LP3PT

30.00 x 24.00 x 8.00 762 x 610 x 203

316L 3.00

A30P24 A30P24G

A30P24SS6

27.00 x 21.00 686 x 533

Large

A30H3008SSLP3PT

30.00 x 30.00 x 8.00 762 x 762 x 203

3.00

A30P30 A30P30G

A30P30SS6

27.00 x 27.00 686 x 686

Large

A30H3008SS6LP3PT

30.00 x 30.00 x 8.00 762 x 762 x 203

316L 3.00

A30P30 A30P30G

A30P30SS6

27.00 x 27.00 686 x 686

Large

A36H2408SSLP3PT

36.00 x 24.00 x 8.00 914 x 610 x 203

3.00

A36P24 A36P24G

A36P24SS6

33.00 x 21.00 838 x 533

Large

A36H2408SS6LP3PT

36.00 x 24.00 x 8.00 914 x 610 x 203

316L 3.00

A36P24 A36P24G

A36P24SS6

33.00 x 21.00 838 x 533

Large

A36H3008SSLP3PT

36.00 x 30.00 x 8.00 914 x 762 x 203

3.00

A36P30 A36P30G

A36P30SS6

33.00 x 27.00 838 x 686

Large

A36H3008SS6LP3PT

36.00 x 30.00 x 8.00 914 x 762 x 203

316L 3.00

A36P30 A36P30G

A36P30SS6

33.00 x 27.00 838 x 686

Large

A48H3608SSLP3PT

48.00 x 36.00 x 8.00 1219 x 914 x 203

3.00

A48P36 A48P36G

A48P36SS6

45.00 x 33.00 1143 x 838

Large

A48H3608SS6LP3PT

48.00 x 36.00 x 8.00 1219 x 914 x 203

316L 3.00

A48P36 A48P36G

A48P36SS6

45.00 x 33.00 1143 x 838

Large

A24H2010SSLP3PT

24.00 x 20.00 x 10.00 610 x 508 x 254

3.00

A24P20 A24P20G

A24P20SS6

21.00 x 17.00 533 x 432

Sm all

Subject to change w ithout notice

PH

(763) 422-2211 • FX (763) 422-2600 • hoffm anonline.com

2010 Pentair Technical Products

Stainless Steel: W all-M ount Enclosures

W all-M ount Enclosures and A ccessories

Spec-00090 F

Catalog Num ber

AxBxC in./m

Stainless Steel Type

F in./m

Steel Panel

Conductive Panel

Stainless Steel Panel

Panel Size D x E in./m

Data Pocket

A24H2010SS6LP3PT

24.00 x 20.00 x 10.00 610 x 508 x 254

316L 3.00

A24P20 A24P20G

A24P20SS6

21.00 x 17.00 533 x 432

Sm all

A36H3010SSLP3PT

36.00 x 30.00 x 10.00 914 x 762 x 254

3.00

A36P30 A36P30G

A36P30SS6

33.00 x 27.00 838 x 686

Large

A36H3010SS6LP3PT

36.00 x 30.00 x 10.00 914 x 762 x 254

316L 3.00

A36P30 A36P30G

A36P30SS6

33.00 x 27.00 838 x 686

Large

A42H3010SSLP3PT

42.00 x 30.00 x 10.00 1067 x 762 x 254

3.00

A42P30 A42P30G

A42P30SS6

39.00 x 27.00 991 x 686

Large

A48H3610SSLP3PT

48.00 x 36.00 x 10.00 1219 x 914 x 254

3.00

A48P36 A48P36G

A48P36SS6

45.00 x 33.00 1143 x 838

Large

A48H3610SS6LP3PT

48.00 x 36.00 x 10.00 1219 x 914 x 254

316L 3.00

A48P36 A48P36G

A48P36SS6

45.00 x 33.00 1143 x 838

Large

A24H2412SSLP3PT

24.00 x 24.00 x 12.00 610 x 610 x 305

3.00

A24P24 A24P24G

A24P24SS6

21.00 x 21.00 533 x 533

Sm all

A24H2412SS6LP3PT

24.00 x 24.00 x 12.00 610 x 610 x 305

316L 3.00

A24P24 A24P24G

A24P24SS6

21.00 x 21.00 533 x 533

Sm all

A30H2412SSLP3PT

30.00 x 24.00 x 12.00 760 x 610 x 305

3.00

A30P24 A30P24G

A30P24SS6

27.00 x 21.00 686 x 533

Large

A30H2412SS6LP3PT

30.00 x 24.00 x 12.00 762 x 610 x 305

316L 3.00

A30P24 A30P24G

A30P24SS6

27.00 x 21.00 686 x 533

Large

A36H3012SSLP3PT

36.00 x 30.00 x 12.00 914 x 762 x 305

3.00

A36P30 A36P30G

A36P30SS6

33.00 X 27.00

838 x 686

Large

A36H3012SS6LP3PT

36.00 x 30.00 x 12.00 914 x 762 x 305

316L 3.00

A36P30 A36P30G

A36P30SS6

33.00 X 27.00

838 x 686

Large

A36H3612SSLP3PT

36.00 x 36.00 x 12.00 914 x 914 x 305

3.00

A36P36 A36P36G

A36P36SS6

33.00 x 33.00 838 x 838

Large

A36H3612SS6LP3PT

36.00 x 36.00 x 12.00 914 x 914 x 305

316L 3.00

A36P36 A36P36G

A36P36SS6

33.00 x 33.00 838 x 838

Large

A42H3612SSLP3PT

42.00 x 36.00 x 12.00 1067 x 914 x 305

3.00

A42P36 A42P36G

A42P36SS6

39.00 x 33.00 991 x 838

Large

A48H3612SSLP3PT

48.00 x 36.00 x 12.00 1219 x 914 x 305

3.00

A48P36 A48P36G

A48P36SS6

45.00 x 33.00 1143 x 838

Large

A48H3612SS6LP3PT

48.00 x 36.00 x 12.00 1219 x 914 x 305

316L 3.00

A48P36 A48P36G

A48P36SS6

45.00 x 33.00 1143 x 838

Large

A60H3612SSLP3PT

60.00 x 36.00 x 12.00 1524 x 914 x 305

3.00

A60P36 A60P36G

A60P36SS6

57.00 x 33.00 1448 x 838

Large

A60H3612SS6LP3PT

60.00 x 36.00 x 12.00 1524 x 914 x 305

316L 3.00

A60P36 A60P36G

A60P36SS6

57.00 x 33.00 1448 x 838

Large

A48H3616SSLP3PT

48.00 x 36.00 x 16.00 1219 x 914 x 406

3.00

A48P36 A48P36G

A48P36SS6

45.00 x 33.00 1143 x 838

Large

A48H3616SS6LP3PT

48.00 x 36.00 x 16.00 1219 x 914 x 406

316L 3.00

A48P36 A48P36G

A48P36SS6

45.00 x 33.00 1143 x 838

Large

A60H3616SSLP3PT

60.00 x 36.00 x 16.00 1524 x 914 x 406

3.00

A60P36 A60P36G

A60P36SS6

57.00 x 33.00 1448 x 838

Large

A60H3616SS6LP3PT

60.00 x 36.00 x 16.00 1524 x 914 x 406

316L 3.00

A60P36 A60P36G

A60P36SS6

57.00 x 33.00 1448 x 838

Large

Purchase panels separately. Optional stainless steel, com posite and alum inum panels are available for m ost sizes.