AMC 403RD
HARDSTAND
E E
X
SB-2
E A
V E
ACCESS ROAD - 3
A
T
T
T
T
T
T
CI
CI
CI
CI
S
SEE NOTE No. 1
LIGHTING CONTACTOR
H
H
G E
N
L S
L S -1
EXST GENERATOR
ELEC. HANDHOLE(TYP. OF 2EA)
SEE NOTE No. 2
IDS SYSTEM PANEL(GFGI, TYP.)
NOTES
SEE NOTE NO.3
3PH 4W 208Y/20V
EXST PNLBRD "LS1-1"
AND IDS SYSTEM POWER EACH.
3. PROVIDE NEW CKT BRK #7, 8 WITH 20A FOR SECURITY LIGHTING POWER
U/G 3-#10 AWG + 1-#10(G) IN 21mm PVC (TYP.)
TO CKT #7 OF "LS1-1"
TO CKT #7, 8 OF "LS1-1"
OF IDS SYSTEM PANELS. ALL IDS SYSTEM SHOULD BE PROVIDED BY ADVANTOR AS GFGI
2. THE CONTRACTOR SHOULD COORDINATE WITH ADVANTOR FOR EXACT LOCATION
PEDESTRIAN GATE SLIDING GATE
ABOVE GROUND SEE DWG.CD101
2-#10 AWG + 1-#10(G) IN 21mmC (TYP.)
SEE DETAIL DWG. ES503
1PH 120VAC 60Hz
(TYP. OF 20EA)
1/53W LED TYPE "NS-PL"
SECURITY LIGHTING POLE W/
SLIDING GATE AREA. SEE NOTE.4
U/G 2-#10 AWG + 1-#10(G) IN 21mmC (TYP.)
DIRECT TO THE NORTH SKY.(TYP.)
W/PHOTOCELL 1P-120VAC 1KW(MAX.)
ELEC. HELD TYPE. NEMA 4X(SST) ENCL.
PAD LOCKING PROVISION.
SOLID NEUTRAL, GND LUGS &
COIL-1PH 120VAC, W/A-O-M SEL. SW,
CIRCUIT BREAKER TYPE. 2P 30A 600VAC
1. COMBINATION LIGHTING CONTACTOR "LC"
S O
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
A
M A
R K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
SHEET ID
®of Engineers
US Army Corps
%PRODUCTION DATA 4%%PRODUCTION DATA 3%%PRODUCTION DATA 2%
%PRODUCTION DATA 1%
A N
S I
D
F
R E
A S
T D
IS
T R
IC
T
S E
O U
L ,K
O R
E A
U S
A E
D F
E ,E
D ,D
E S
IG
N B
R A
N C
H
IN
-H
O U
E
B p o fp w a d m in
A E
C S h e e tS e e d .d g n
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
U S
A G H
U M
P H
R E
Y S
K O
R E
A
GFGI
OF IDS SYSTEM PANELS. ALL IDS SYSTEM SHOULD BE PROVIDED BY ADVANTOR AS
2. THE CONTRACTOR SHOULD COORDINATE WITH ADVANTOR FOR EXACT LOCATION
DIRECT TO THE NORTH SKY.(TYP.)
W/PHOTOCELL 1P-120VAC 1KW(MAX.)
ELEC. HELD TYPE. NEMA 4X(SST) ENCL.
PAD LOCKING PROVISION.
SOLID NEUTRAL, GND LUGS &
COIL-1PH 120VAC, W/A-O-M SEL. SW,
CIRCUIT BREAKER TYPE. 2P 30A 600VAC
1. COMBINATION LIGHTING CONTACTOR "LC"
NOTES
AND PNLBRD "LS1-1"
AND IDS SYSTEM POWER EACH. PROVIDE LOCKING DEVICE TO CKT BRK #7, 8
3. PROVIDE NEW CKT BRK #7, 8 WITH 20A FOR SECURITY LIGHTING POWER
S P
T W
A R
E H
O U
S E A
R E
A
S E
C U
R
IT
Y F
E N
C E
ES101
EXTERIOR ELEC. POWER DISTRIBUTION PLAN
1:200 10000mm5000mm0mm
E X
T E
R
IO
R E
L E
C P
O W
E R D
IS
T R
IB
U T
IO
N P
L
BETWEEN U/G ELEC. & COMM. CONDUIT
4. THE CONTRACTOR SHOULD SEPARATE FOR RUNNING
AMC 403RD
HARDSTAND HARDSTAND
BLDG A
FIRE PUMP J
FNSH FL EL 8.65
O N
L Y
V E
H
IC
L E
C A
R P
O O
L
L Y
V E
H
IC
L E
C A
R P
O
L Y
V E
H
IC
L E
C A
R P
O
V
H
IC
L E
E F F
IC
IE
N T
F U
E L
E M
IS
S
IO
N
L O
W
V E
H
IC
L E
E F F
IC
IE
N T
F U
E L
E M
IS
S
IO
N
L O
W
V E
H
IC
L E
E F F
IC
IE
N T
F U
E L
E M
IS
S
IO
N
L O
W
V E
H
IC
L E
E F F
IC
IE
N T
F U
E L
E M
IS
S
IO
N
L O
W
O N
L Y
V E
H
IC
L E
C A
R P
O
(F-95064)
HARDSTAND A
COVERED
1st SIGNAL
BLDG H
FNSH FL EL 7.50
DN
UP UP
DNDN
DN
DN
DN
DN
DN DN
C
C
PTZ
1B
C
C
C
J
1st ST. 1st ST.
E A
V E
ACCESS ROAD - 3
A
A
T
T
T
TT
T
T
T
T
T T
T
T T
T
T
T
C I
C I
CI
CI
CI
CI
CI
C I
C I
C I
C I
C I
C I
C I
C I
C I
C I
C I
C I
C I
C I
CI
CI
CI
CI
CI
SSS
S
S S
T
B
TSB230
T
T
S O
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
A
M A
R K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
SHEET ID
®of Engineers
US Army Corps
SEE NOTE No. 1
IDS SYSTEM PANEL(GFGI, TYP.)
NOTES
MH3014
MH3015
C
C
C x
Cx
Cx
Cx C
GATES
PEDESTRIAN
SLIDING GATES
30ft WIDE
BLDG A
HARDSTAND
SPT060-4
EXTERIOR COMMUNICATION PLAN
1:500 25000mm12500mm0mm
OF IDS SYSTEM PANELS. ALL IDS SYSTEM SHOULD BE PROVIDED BY ADVANTOR AS GFGI
1. THE CONTRACTOR SHOULD COORDINATE WITH ADVANTOR FOR EXACT LOCATION
CMH3305
C x
No. 127-132( TYP.)
TO WARRIOR SUPPORT FOC 6
6CORE FOC SPLICING POINT
MAIN COMM ROOM
IN EXST 1WAY-103mmC COMM. DUCT W/ EXST FABRIC MESH (TYP.)
FROM COMM ROOM 232 OF WHARE HOUSE TO MH3015 VIA MH3014
ADD 1EA-12STRAND SM FOC IN EXST 1CELL
IN EXST 1WAY-103mmC COMM. DUCT W/ EXST FABRIC MESH (TYP.)
FROM COMM ROOM 232 OF WHARE HOUSE TO MH3015 VIA MH3014
ADD 1EA-12STRAND SM FOC IN EXST 1CELL
VIA MH3014, 3015(TYP.)
FROM MH3305 TO COMM ROOM 232 OF WAREHOUSE
IN EXST 1WAY-103mmC COMM. DUCT W/ EXST FABRIC MESH
ADD 1EA-6STRAND SM FOC
VIA MH3014, 3015(TYP.)
FROM MH3305 TO COMM ROOM 232 OF WAREHOUSE
IN EXST 1WAY-103mmC COMM. DUCT W/ EXST FABRIC MESH
ADD 1EA-6STRAND SM FOC
C x
C
EXST MANHOLE "M1"
FACILITY
WEATHER FORECAST
FROM MH3015 TO M1(TYP.)
IN EXST 1WAY-103mmC COMM. DUCT W/ EXST FABRIC MESH
ADD 1EA-12STRAND SM FOC
FROM M1 TO FIBER OPTIC SENSOR PANEL(IDS)
2WAY-103mmC W/ FABRIC MESH 2EA-3CELL FOR SPARE
& 5EA CELLS FOR THE SPARE(TYP.)
1EA-12STRAND SM FOC
NEW 3WAY-103mmC COMM. DUCT W/ NEW FABRIC MESH 2EA-3CELL
"#B-2"
EXST PMS
S O
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
A
M A
R K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
SHEET ID
®of Engineers
US Army Corps
S
R E
A S
T D
IS
T R
IC
T
S E
O U
L ,K
O R
E A
U S
A E
D F
E ,E
D ,D
E S
IG
N B
R A
N C
H
IN
-H
O U
B p o fp w a d m in
A E
C S h e e tS e e d .d g n
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
U S
A G H
U M
P H
R E
Y S
K O
R E
A
S P
T W
A R
E H
O U
S E A
R E
A
S E
C U
R
IT
Y F
E N
C E
TS101
E X
T E
R
IO
R C
O M
M U
N
IC
A T
IO
N P
L
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
A
M A
R K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
SHEET ID
®of Engineers
US Army Corps
-1.0 +1.5
Rubber Cap
OPEN LOCK
O
P E
N
L O
C K
O P
E N
L O C
K
HOLE
LIFTING
STEEL FRAME
,1
0,2 0,2
1, (1/4")
EXPANSION SHIELDS
130mm
6mm
(5")
INSULATOR
FASTEN BY MEANS OF
RADIUS PORCELAIN
(1/2") BOLTS AND
54mm(2-1/8")
"A"
ELECTRICAL / TEL. HANDHOLE AND APPURTENANCE DETAILS
"A"
A
A
NOTES ( FOR HANDHOLE)
P L A N
NOTES
A-A SECTION VIEW
STEEL COVER
TELECOMMUNICATION OR ELECTRICAL
IN LETTER BLOCKS
(2-1/4")
55mm m m
64mm(2-1/2")x13mm
(1 -1 /2
(FOR ELECTRICAL) (FOR TEL CABLE)
CABLE RACK
(2-1/4")
55mm
FASTEN BY MEANS OF
64mm(2-1/2")x13mm
(1/2") BOLTS AND
25mm(1")
EXPANSION SHIELDS
(2-1/4")
55mm m m
PULLING-IN IRON
(1 -1 /2
T O P
MIN. OPENING
SECTION A - A'
1 NOT TO SCALE
130mm
(1/4")
(5")
915mm(36")
6mm
(3")
(9")
76mm
SOLDERED JOINT
230mm
SUMP
SLOPE TO DRAIN
END BELLS
21mm
(7/8")
COPPER FLASHING
25mm(1")
50mm(2")
DUCT WINDOW SEALING
WIDE SHEET
DUCT
GROUT
EMBEDMENT
EDGE OF
DUCT WINDOW
CORNERS & INTERSECTIONS
3. WALL & FLOOR;---MIN. 8" CENTERS W/12" HOOK AT
4. REINFORCING BARS,------NO. 4 ROUND DEFORMED
A MIN 4" SPACING BETWEEN BARS.
5. AS SHOWN AT A MIN 2" FOR OPENING AND WITH
(TYPICAL)
#4 AWG "BC"
GROUND WIRE
SUMP WALL AND FLOOR--------4'
WALL, TOP AND FLOOR---------6"
1. THICKNESS OF CONCRETE;
2. REINFORCING BARS,------NO. 4 ROUND DEFORMED
SEE SPEC.33 71 02
GROUND ROD
SEE SPEC.33 71 02
GROUND ROD
GALVANIZED.
2. ALL STEEL HARDWARES TO BE HOT DIPPED
SEE DWG. E-001,E-002
1. FOR ABBREVIATION, LEGEND AND GENERAL NOTES,
1/2 INCH ABOVE THE FINISHED GRADE.
AREAS THE TOP OF HANDHOLE COVER SHALL BE APPROX
THE FINISHED SURFACE OF THE PAVING. IN UNPAVED
6. THE TOP OF HANDHOLE COVER SHALL BE FLUSH WITH
ELECTRICAL FOR POWER, TELECOMMUNICATION FOR COMM.
7. THE NAME ON MANHOLE COVER SHALL HAVE ITS UTILITY NAME ;
G
AND FRAME
SUMP COVER
(TYP.)
CABLE RACK
IRON (TYP.)
PULLING-IN
4 MIN.
CABLE RACKS
ENTRANCE
EACH DUCT
OPPOSITE
IRON ONE
PULLING-IN
IRON
PULLING-IN
G
& QTY AS REQ'D
CONDUIT SIZE
(TYPICAL)
#4 AWG "BC"
GROUND WIRE
G
G
G approved equal
3. HANGUG CASTING/awp agent (model : HCF-041) or
- pad locking device system
- solid lid
- watertight frame
2. Inner lid shall be required as follow
- locking device system
- loading : 40,000 pound plus 30%
1. Manhole Cover are requirements as follow
S
R E
A S
T D
IS
T R
IC
T
S E
O U
L ,K
O R
E A
U S
A E
D F
E ,E
D ,D
E S
IG
N B
R A
N C
H
IN
-H
O U
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
ES501
E L E
C T
R
IC
A L D
E T
A
IL
S -1 j1 e d d c s p
P A
K .C
S
D A
L T
O N .N
G O
C -A
N H
A N .K
Y
C A
Y W
O O
D .C
H R
IS
W
U S
A G H
U M
P H
R E
Y S
K O
R E
A
S T P W
A R
E H
O U
S E A
R E
A
S E
C U
R
IT
Y F
E N
C E
A u g u s t2
E S
X X
X .d g n
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
A
M A
R K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
SHEET ID
®of Engineers
US Army Corps
WIDTH VARIES
CONCRETE
103mm103mm m m
4-WAY DUCT (TRAFFIC AREA)
76mm
76mm m m
76mm 76mm51mm51mm
3-WAY DUCT (TRAFFIC AREA)
m m
76mm
WIDTH VARIES
CONCRETE
103mm
76mm
76mm
103mm 103mm 103mm
CONCRETE
m m m m
4-WAY DUCT (NON-TRAFFIC AREA)
WIDTH VARIES
50mm1 m m m m
50mm
1-WAY DUCT (NON-TRAFFIC)
m m m m m m
2-WAY DUCT (NON-TRAFFIC AREA)
76mm
WIDTH VARIES
3-WAY DUCT (NON-TRAFFIC AREA)
WIDTH VARIES
50mm
2-WAY DUCT (TRAFFIC AREA)
m m
50mm
WIDTH VARIES
76mm m m
9-WAY DUCT (NON-TRAFFIC AREA)
m m
WIDTH VARIES
m m
76mm
471mm
76mm169mm
DUCT SPACER
169mm
WIDTH VARIES
m m m m m m
76mm m m m m m m m m
50mm 50mm
5-WAY DUCT (NON-TRAFFIC AREA)
50mm 50mm
76mm
76mm
76mm
DUCT SPACER
76mm
76mm50mm
DUCT SPACER
76mm
COMPACTED BACKFILL
WARNING TAPE
WIDTH VARIES
m m m m m m
GRADE
FINISHED
CUSHION
SAND
BACKFILL
COMPACTED
AS REQUIRED)
(SIZE & QUANTITY
PVC CONDUIT
(SIZE AS REQ'D)
PVC CONDUIT
REQUIRED)
(SIZE AS
PVC CONDUIT
TAPE
WARNING
BACKFILL
COMPACTED
CUSHION
SAND
GRADE
FINISHED
SIZE AS REQUIRED
PVC CONDUIT (TYP)
TAPE
WARNING
BACKFILL
COMPACTED
TRACER WIRE
#12 AWG INSULATED
CUSHION
SAND
ENCASEMENT
CONCRETE
TRACER WIRE
#12 AWG INSULATED
AS REQUIRED)
(SIZE & QUANTITY
PVC CONDUIT
BACKFILL
COMPACTED
TAPE
WARNING
BACKFILL
COMPACTED
CUSHION
SAND
TRACER WIRE
#12 AWG INSULATED
ENCASEMENT
CONCRETE
TAPE
WARNING
AS REQUIRED)
(SIZE & QUANTITY
PVC CONDUIT
TRACER WIRE
#12 AWG INSULATED
TAPE
WARNING
TRACER WIRE
#12 AWG INSULATED
CUSHION
SAND
TRACER WIRE
#12 AWG INSULATED
GRADE
FINISHED
TRACER WIRE
#12 AWG INSULATED
SIZE AS REQUIRED
PVC CONDUIT (TYP)
CUSHION
SAND
TRACER WIRE
#12 AWG INSULATED
AS REQUIRED)
(SIZE & QUANTITY
PVC CONDUIT
TAPE
WARNING
BACKFILL
COMPACTED
AS REQUIRED)
(SIZE & QUANTITY
PVC CONDUIT
ENCASEMENT
CONCRETE
CUSHION
SAND
AS REQUIRED)
(SIZE & QUANTITY
PVC CONDUIT
BACKFILL
COMPACTED
TAPE
WARNING
CUSHION
SAND
TRACER WIRE
#12 AWG INSULATED
CUSHION
SAND
TAPE
WARNING
BACKFILL
COMPACTED
S
R E
A S
T D
IS
T R
IC
T
S E
O U
L ,K
O R
E A
U S
A E
D F
E ,E
D ,D
E S
IG
N B
R A
N C
H
IN
-H
O U
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
ES502
E L E
C T
R
IC
A L D
E T
A
IL
S -2 j1 e d d c s p
P A
K .C
S
D A
L T
O N .N
G O
C -A
N H
A N .K
Y
C A
Y W
O O
D .C
H R
IS
W
U S
A G H
U M
P H
R E
Y S
K O
R E
A
S T P W
A R
E H
O U
S E A
R E
A
S E
C U
R
IT
Y F
E N
C E
E S
X X
X .d g n
A u g u s t
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
A
M A
R K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
SHEET ID
®of Engineers
US Army Corps
NOTES
PARKING & STREET LIGHT DETAIL(NS-PL)
STUBBED OUT 103mm
(TYP.)
POLE (TYP.)
ANCHOR BOLT
19mm DIA.x 406mm LONG
762mm x 762
762mm SQ.
NOT TO SCALE
POLE FOUNDATION DETAIL
PVC CONDUIT
TO OTHER LIGHT
G.L.
BASE PLATE
PEDESTAL W/ 8-#6 VERTICAL BARS
& #3 TIES @ 254 mm
100mm m m
#6,"BC"
G m m
#6"BC"GROUND WIRE
GROUND LUG AND
4000 PSI IN 28 DAY
CONCRETE
SEE SPEC.
GROUND ROD,
DOOR OPENING
FOR LIGHTING JUNCTION BOX
SIZE AS REQUIRED(TYP)
BASE BOLT COVER
COUPLING(TYP.)
GALVANIZED.
1. ALL POLE HARDWARES TO BE HOT DIPPED
,0
-AMBIENT TEMPERATURE : -40 ~ 40 Degrees
-LED & OPTICAL ASSEMBLY TYPE : OPTIMIZED LED ARRAY
BASED ON DISTRIBUTION PATTERN
-3ME - ASYMMETRIC TYPE
-DIMENSION : W635 * L482 * H122 (mm)
FEATURES
GENERAL DESCRIPTION
-COLOR TEMPERATURE & CRI : 5700K & 70RA
-FINISH : Corrosion Resistant Ultra-Durable Powder Painting
-MATERIAL : DIE-CAST Aluminum
-MOUNTING : POLE
-RATINGS : Enclosure rated IP66 per IEC 60529
-LIFE TIME : 100,000 Hours @ L70
-NET WEIGHT & EPA : 12KG & 0.14 SQ M MAX
BASE PLATE DETAILHAND HOLE DETAIL
4-30X70L SLOT HOLE
2. LED LIGHT SHALL COMPLY WITH LM-79 & LM-80 TEST
AND SHALL BE UL LISTED.
1. LED CONVERTOR SHALL COMPLY WITH UL 8750, UL935
NOTE.
-PROFILE : LED OUTDOOR STREET LIGHTING FIXTURE
25.0"(635mm)
8.1"(206mm)
.1 m m
.8 m m
.8 m m
.0 m m
POLE TEMPLATE DETAILARM DETAIL
Hole 2 Required
0.344" (9mm)
Hole
0.5" (13mm)
(5 m m
(5 m m
(2 m m
25.0"(635mm)
8.1"(206mm)
.1 m m
.8 m m
.8 m m
.0 m m
Backing Plate
Pole Mount Adapter
Backing Plate
5/16" Hex Nut Pole
Foam Gasket
Pole Mount Adapter
Pole
-POWER SUPPLY : UNI Volt 277V AC
BOTTOM-180mm DIA
POLE SHAFT SIZE(7m) :TOP-90mm DIA
STKT590(ATOS60) 3.2mmTHICK
TAPERD AND ROUND
HOT DIP GALVANIZED STEEL POLE
(SUBSTITUTE THE METAL HALIDE LAMP 250W)
-TYPICAL INITIAL LUMEN : *53W(3ME TYPE) - 7,113LM
S
R E
A S
T D
IS
T R
IC
T
S E
O U
L ,K
O R
E A
U S
A E
D F
E ,E
D ,D
E S
IG
N B
R A
N C
H
IN
-H
O U
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
ES503
E L E
C T
R
IC
A L D
E T
A
IL
S -3 j1 e d d c s p
P A
K .C
S
D A
L T
O N .N
G O
C -A
N H
A N .K
Y
C A
Y W
O O
D .C
H R
IS
W
U S
A G H
U M
P H
R E
Y S
K O
R E
A
S T P W
A R
E H
O U
S E A
R E
A
S E
C U
R
IT
Y F
E N
C E
A u g u s t
E S
X X
X .d g n
Subject to change w ithout notice
PH
(763) 422-2211 • FX (763) 422-2600 • hoffm anonline.com
2010 Pentair Technical Products
Stainless Steel: W all-M ount Enclosures
W all-M ount Enclosures and A ccessories
Spec-00090 F
Spec-00090
FPH (763) 422-2211
FX (763) 422-2600
Stainless Steel W all-M ount Enclosures
W all-M ount Enclosures and A ccessories
Continuous H inge w ith 3-Point Latch, Type 4X
Industry Standards
U L 508A
Listed; Type 3R, 4, 4X, 12; File N
o. E61997 cU L Listed per CSA
C22.2 N o 94; Type 3R, 4, 4X, 12; File N o.
E61997
N
EM
A
/EEM
AC Type 3R, 4, 4X, 12, 13
IEC 60529, IP66
M eets N
EM
A Type 3RX requirem ents
A pplication
These enclosures feature H offm an’s exclusive PO W
ERG
LID
E® H andle w ith 3-point latching, ideal for indoor or outdoor applications that require corrosion protection, convenient access, and padlocking security.
Specifications
14 gauge Type 304 or 316L stainless steel bodies and doors
Seam s continuously w elded and ground sm ooth
Seam less foam -in-place gasket
Rolled lip around three sides of door
Internal 3-point latch and Type 316L stainless steel padlocking
PO
W
ERG
LID
E H andle
Rem ove door by pulling stainless steel continuous hinge pin
D ata pocket is high-im pact therm oplastic
Collar studs provided for m ounting optional panels
Exterior hardw are on Type 316L stainless steel enclosures m atches enclosure m aterial
Bonding provision on door; grounding stud on body
Finish D oor, sides, top and bottom have sm ooth #4 brushed finish. H andle is electropolished.
A ccessories
See also Accessories.
Panels for Type 3R, 4, 4X, 12 and 13 Enclosures Steel and Stainless Steel W indow Kits
H 2O
M IT ® Vent D rains, Type 4X H
2O M
IT ® Therm oelectric D ehum idifier
M odification and Custom ization H offm an excels at m odifying and custom izing products to your specifications. Contact your local H offm an sales offi ce or distributor for com plete inform ation.
Bulletin: A
4SW
Standard Product
Catalog Num ber
AxBxC in./m m
Stainless Steel Type
F in./m
Steel Panel
Conductive Panel
Stainless Steel Panel
Panel Size D x E in./m
Data Pocket
A24H2006SSLP3PT
24.00 x 20.00 x 6.00 610 x 508 x 152
3.00
A24P20 A24P20G
A24P20SS6
21.00 x 17.00 533 x 432
Sm all
A24H2006SS6LP3PT
24.00 x 20.00 x 6.00 610 x 508 x 152
316L 3.00
A24P20 A24P20G
A24P20SS6
21.00 x 17.00 533 x 432
Sm all
A24H2008SSLP3PT
24.00 x 20.00 x 8.00 610 x 508 x 203
3.00
A24P20 A24P20G
A24P20SS6
21.00 x 17.00 533 x 432
Sm all
A24H2008SS6LP3PT
24.00 x 20.00 x 8.00 610 x 508 x 203
316L 3.00
A24P20 A24P20G
A24P20SS6
21.00 x 17.00 533 x 432
Sm all
A24H2408SSLP3PT
24.00 x 24.00 x 8.00 610 x 610 x 203
3.00
A24P24 A24P24G
A24P24SS6
21.00 x 21.00 533 x 533
Sm all
A24H2408SS6LP3PT
24.00 x 24.00 x 8.00 610 x 610 x 203
316L 3.00
A24P24 A24P24G
A24P24SS6
21.00 x 21.00 533 x 533
Sm all
A30H2408SSLP3PT
30.00 x 24.00 x 8.00 762 x 610 x 203
3.00
A30P24 A30P24G
A30P24SS6
27.00 x 21.00 686 x 533
Large
A30H2408SS6LP3PT
30.00 x 24.00 x 8.00 762 x 610 x 203
316L 3.00
A30P24 A30P24G
A30P24SS6
27.00 x 21.00 686 x 533
Large
A30H3008SSLP3PT
30.00 x 30.00 x 8.00 762 x 762 x 203
3.00
A30P30 A30P30G
A30P30SS6
27.00 x 27.00 686 x 686
Large
A30H3008SS6LP3PT
30.00 x 30.00 x 8.00 762 x 762 x 203
316L 3.00
A30P30 A30P30G
A30P30SS6
27.00 x 27.00 686 x 686
Large
A36H2408SSLP3PT
36.00 x 24.00 x 8.00 914 x 610 x 203
3.00
A36P24 A36P24G
A36P24SS6
33.00 x 21.00 838 x 533
Large
A36H2408SS6LP3PT
36.00 x 24.00 x 8.00 914 x 610 x 203
316L 3.00
A36P24 A36P24G
A36P24SS6
33.00 x 21.00 838 x 533
Large
A36H3008SSLP3PT
36.00 x 30.00 x 8.00 914 x 762 x 203
3.00
A36P30 A36P30G
A36P30SS6
33.00 x 27.00 838 x 686
Large
A36H3008SS6LP3PT
36.00 x 30.00 x 8.00 914 x 762 x 203
316L 3.00
A36P30 A36P30G
A36P30SS6
33.00 x 27.00 838 x 686
Large
A48H3608SSLP3PT
48.00 x 36.00 x 8.00 1219 x 914 x 203
3.00
A48P36 A48P36G
A48P36SS6
45.00 x 33.00 1143 x 838
Large
A48H3608SS6LP3PT
48.00 x 36.00 x 8.00 1219 x 914 x 203
316L 3.00
A48P36 A48P36G
A48P36SS6
45.00 x 33.00 1143 x 838
Large
A24H2010SSLP3PT
24.00 x 20.00 x 10.00 610 x 508 x 254
3.00
A24P20 A24P20G
A24P20SS6
21.00 x 17.00 533 x 432
Sm all
Subject to change w ithout notice
PH
(763) 422-2211 • FX (763) 422-2600 • hoffm anonline.com
2010 Pentair Technical Products
Stainless Steel: W all-M ount Enclosures
W all-M ount Enclosures and A ccessories
Spec-00090 F
Catalog Num ber
AxBxC in./m
Stainless Steel Type
F in./m
Steel Panel
Conductive Panel
Stainless Steel Panel
Panel Size D x E in./m
Data Pocket
A24H2010SS6LP3PT
24.00 x 20.00 x 10.00 610 x 508 x 254
316L 3.00
A24P20 A24P20G
A24P20SS6
21.00 x 17.00 533 x 432
Sm all
A36H3010SSLP3PT
36.00 x 30.00 x 10.00 914 x 762 x 254
3.00
A36P30 A36P30G
A36P30SS6
33.00 x 27.00 838 x 686
Large
A36H3010SS6LP3PT
36.00 x 30.00 x 10.00 914 x 762 x 254
316L 3.00
A36P30 A36P30G
A36P30SS6
33.00 x 27.00 838 x 686
Large
A42H3010SSLP3PT
42.00 x 30.00 x 10.00 1067 x 762 x 254
3.00
A42P30 A42P30G
A42P30SS6
39.00 x 27.00 991 x 686
Large
A48H3610SSLP3PT
48.00 x 36.00 x 10.00 1219 x 914 x 254
3.00
A48P36 A48P36G
A48P36SS6
45.00 x 33.00 1143 x 838
Large
A48H3610SS6LP3PT
48.00 x 36.00 x 10.00 1219 x 914 x 254
316L 3.00
A48P36 A48P36G
A48P36SS6
45.00 x 33.00 1143 x 838
Large
A24H2412SSLP3PT
24.00 x 24.00 x 12.00 610 x 610 x 305
3.00
A24P24 A24P24G
A24P24SS6
21.00 x 21.00 533 x 533
Sm all
A24H2412SS6LP3PT
24.00 x 24.00 x 12.00 610 x 610 x 305
316L 3.00
A24P24 A24P24G
A24P24SS6
21.00 x 21.00 533 x 533
Sm all
A30H2412SSLP3PT
30.00 x 24.00 x 12.00 760 x 610 x 305
3.00
A30P24 A30P24G
A30P24SS6
27.00 x 21.00 686 x 533
Large
A30H2412SS6LP3PT
30.00 x 24.00 x 12.00 762 x 610 x 305
316L 3.00
A30P24 A30P24G
A30P24SS6
27.00 x 21.00 686 x 533
Large
A36H3012SSLP3PT
36.00 x 30.00 x 12.00 914 x 762 x 305
3.00
A36P30 A36P30G
A36P30SS6
33.00 X 27.00
838 x 686
Large
A36H3012SS6LP3PT
36.00 x 30.00 x 12.00 914 x 762 x 305
316L 3.00
A36P30 A36P30G
A36P30SS6
33.00 X 27.00
838 x 686
Large
A36H3612SSLP3PT
36.00 x 36.00 x 12.00 914 x 914 x 305
3.00
A36P36 A36P36G
A36P36SS6
33.00 x 33.00 838 x 838
Large
A36H3612SS6LP3PT
36.00 x 36.00 x 12.00 914 x 914 x 305
316L 3.00
A36P36 A36P36G
A36P36SS6
33.00 x 33.00 838 x 838
Large
A42H3612SSLP3PT
42.00 x 36.00 x 12.00 1067 x 914 x 305
3.00
A42P36 A42P36G
A42P36SS6
39.00 x 33.00 991 x 838
Large
A48H3612SSLP3PT
48.00 x 36.00 x 12.00 1219 x 914 x 305
3.00
A48P36 A48P36G
A48P36SS6
45.00 x 33.00 1143 x 838
Large
A48H3612SS6LP3PT
48.00 x 36.00 x 12.00 1219 x 914 x 305
316L 3.00
A48P36 A48P36G
A48P36SS6
45.00 x 33.00 1143 x 838
Large
A60H3612SSLP3PT
60.00 x 36.00 x 12.00 1524 x 914 x 305
3.00
A60P36 A60P36G
A60P36SS6
57.00 x 33.00 1448 x 838
Large
A60H3612SS6LP3PT
60.00 x 36.00 x 12.00 1524 x 914 x 305
316L 3.00
A60P36 A60P36G
A60P36SS6
57.00 x 33.00 1448 x 838
Large
A48H3616SSLP3PT
48.00 x 36.00 x 16.00 1219 x 914 x 406
3.00
A48P36 A48P36G
A48P36SS6
45.00 x 33.00 1143 x 838
Large
A48H3616SS6LP3PT
48.00 x 36.00 x 16.00 1219 x 914 x 406
316L 3.00
A48P36 A48P36G
A48P36SS6
45.00 x 33.00 1143 x 838
Large
A60H3616SSLP3PT
60.00 x 36.00 x 16.00 1524 x 914 x 406
3.00
A60P36 A60P36G
A60P36SS6
57.00 x 33.00 1448 x 838
Large
A60H3616SS6LP3PT
60.00 x 36.00 x 16.00 1524 x 914 x 406
316L 3.00
A60P36 A60P36G
A60P36SS6
57.00 x 33.00 1448 x 838
Large
Purchase panels separately. Optional stainless steel, com posite and alum inum panels are available for m ost sizes.