21._Attachment_G_-_Supplemental_Information.pdf
PDF 3 MB Posted
- Attached to
- Archer Substation kV2A Transformer Replacement Federal contract opportunity
- Solicitation number
- DE-SOL-0009343
About this file
Attachment G - Supplemental Information
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 21._Attendance_Prebid_site_visit.pdf | ||
| 21._DE-SOL-0009343_AMD_00001.pdf | ||
| 21._Attachment_B_-_Drawings_-_Archer_Sub_KV2A_Transformer_Replacement.pdf | ||
| 21._Attachment_F_-_Bid _Performance _Payment_Bonds.pdf | ||
| 21._Attachment_D_-_Foreign_National_Data_Card.pdf | ||
| 21._Attachment_C_-_Wage_Determinations.pdf | ||
| 21._DE-SOL-0009343.pdf | ||
| 21._Attachment_A_-_Specifications_-_Archer_Sub_KV2A_Transformer_Replacement.pdf | ||
| 21._IFB_Letter.pdf | ||
| 21._Attachment_E_-_CRD_DPO.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
29 June 2016
Attachment G
Archer Substation KV2A Transformer Replacement Supplemental Information
DE-SOL-0009343
CG POWER SYSTEMS CANADA INC MA120448C REV.3 DATE: 23-Apr-14 PAGE 1 OF 10
OUTLINE LEGEND -
CUSTOMER-- LUNA DIVERSIFIED ENTERPRISES
PURCHASE ORDER No.-- CUF 03506-01
CG POWER SYSTEMS CANADA INC S.O. No.-- RA12.0448
CG POWER SYSTEMS CANADA INC QUOTE No.-- 12001
MVA-- 120/160/200
TYPE-- ONAN/ONAF/ONAF
PHASE-- 3 HERTZ-- 60 TEMPERATURE RISE-- 65C
VOLTAGE-- HV: 230 WYE/132.8kV.
LV: 115 WYE/66.4kV
TERT: 13.8kV DELTA
HOXO: 13.8kV
HV DE-ENERGIZED TAPS-- + /-5% IN + /-2 STEPS
CUSTOMER SPEC. -- 12W95444
LOCATION-- LARAMIE COUNTY, WY
CHECKED BY-- VDJ JAN-22-13
CERTIFIED BY--
DATE--
CG POWER SYSTEMS CANADA INC MA120448C REV.3 DATE: 23-Apr-14 PAGE 2 OF 10
SECTION 600
* TM-602.00
INDEX-STANDARD AND OPTIONAL ACCESSORIES
HV Bushing 230 kV, 800 Amp, 900 kV BIL PCORE Identification # POC900G0800S
To ANSI STD Top Stud 1 1/2"-12 TPI x 2” Long, Bulletin # 580
* TM-602.B0 HV Bushing Top Connector, PCORE Test Terminal #63056-70 For Stud 1 1/2"-12 TPI
To 4 Hole Nema Pad
* TM-604.00 LV Bushing 115 kV, 1200 Amp, 550 kV BIL PCORE Identification #
POC550G1216RS To ANSI STD Top Stud 1 1/2"-12 TPI x 2” Long, Bulletin # 580
* TM-604.B0 LV Bushing Top Connector, PCORE Test Terminal #63056-70 For Stud 1 1/2"-12 TPI
To 4 Hole Nema Pad
* TM-608.00 TV Bushing 25 kV, 3000 Amp, 150 kV BIL PCORE Identification # B-88733-70 To
ANSI STD Top Stud 2"-12 TPI x 2 1/8” Long, Bulletin # 580
* TM-608.B0 TV Bushing Top Connector, PCORE Test Terminal #63055-70 For Stud 2"-12 TPI To
4 Hole Nema Pad
* TM-610.A0 HOXO Bushing 25 kV, 400/1200 Amp, 150 kV BIL PCORE Identification # B-89293-
70 To ANSI STD Top Stud 1 1/2"-12 TPI x 2 1/2” Long, Bulletin # 580
* TM-610.C0 H0X0 Bushing Top Connector, For Stud 1 1/2"-12 TPI To 4 Hole Nema Pad
* 610.EA Ground Cable 4/0 Bare Copper Terminated At Ground Pad (See Point 658.B0)
*** TM-611.BM Bushing Monitor (Mounted In Control Cabinet)
* TM-612.00 HV Surge Arrester 172 kV, 140 kV MCOV Cooper Cat. # UH172A
* TM-612.CC Ground Support Connector
* 612.CF Ground Cable 4/0 Bare Copper Terminated At Ground Pads (See Point 658.B0)
* 612.DA HV Surge Arresters Support
* TM-613.00 LV Surge Arrester 90 kV, 70 kV MCOV Cooper Cat. # UH090A
TM-613.CC Ground Support Connector
CG POWER SYSTEMS CANADA INC MA120448C REV.3 DATE: 23-Apr-14 PAGE 3 OF 10
* 613.CF Ground Cable 4/0 Bare Copper Terminated At Ground Pads (See Point 658.B0)
* 613.DA LV Surge Arresters Support
* TM-614.00 TV Surge Arrester 18 kV, 15.3 kV MCOV Cooper Cat. # UH018A
TM-614.CC Ground Support Connector
* 614.CF Ground Cable 4/0 Bare Copper Terminated At Ground Pads (See Point 658.B0)
* 614.DA TV Surge Arrester Support
* 618.05 Removable Type Radiators, Galvanized
618.A0 - Lifting Lugs
618.B0 - 1” Drain Boss c/w Brass Plug
618.C0 - 1” Vent Boss c/w Bleeder Valve
** 618.D1 - Detachable Radiator Cross Bracing
TM-618.E6 Radiator Shut-Off Valve c/w Provision For Padlocking In Open Or Closed Position
* TM-624.00 Weatherproof Cooling Fans 240/1/60, 1/2 HP
TM-626.B0 Pressure Relief Device 10 PSIG Self Reclosing
626.T0 Shroud To Direct Oil Away From Tank
627.A0 Dry Air Pressure System For Shipping Purposes Only c/w:
627.AB - Pressure Release Valve QualiTROL # 351-2A And Pressure-Vacuum Gauge # 050-
010-01 (For Indication Of Pressure In Tank During Shipment)
* TM-629.AA Rapid Pressure Rise Relay c/w 2” NPS Shut-Off Ball Valve QualiTROL #900-025-01
(For Oil Use Only)
* TM-631.FA Gas Detector Relay (Buchholz) c/w Set Of Contacts To Close On Slow Gas
Accumulation Or Rapid Increase In Pressure
CG POWER SYSTEMS CANADA INC MA120448C REV.3 DATE: 23-Apr-14 PAGE 4 OF 10
631.G0 Gas Detector Relay Gas Pipework
631.I0 For Gas Detector Relay Testing Purposes 1/2” NPS Ball Valve (Shop Note:
Remove Valve And Install 1/2" Brass Plug Before Final Paint And Processing)
TM-632.A2 Liquid Level Gauge 2” (50mm) Dial Face (CG Power Systems Canada Inc Requirement
For Vacuum Filling Purposes)
TM-632.AA Liquid Level Gauge 6” Dial Face For Air Bag Leak Detection c/w Liquid Level Trip
Contact (For Description See TM-632.01) For Air Bag Leak Detection
TM-632.AB Liquid Level Gauge 6” Dial Face c/w Low Liquid Level Alarm Contact, For
Conservator Oil Level Indication (For Description See TM-632.01)
TM-635.D0 Winding Temperature Indicator
TM-635.E0 Liquid Temperature Indicator
*** TM-635.EX Electronic Temperature Monitor (ETM) (Mounted In Control Cabinet)
636.BX Resistance Temperature Detector c/w Well (100 OHM @ 0 º C)
*** 636.CT Ambient Resistance Temperature Detector (Mounted On Control Cabinet)
TM-636. F0 Thermal Plate
* TM-637.F1 Silica Gel Dehydrating Breather 60 lbs
639.00 Rating Plate And Connection Diagram Mounted On The Control Cabinet Door
. 641.D0 Transformer Drain/Lower Filter Press Connection 2” Flanged Inlet-Threaded Outlet
Globe Valve c/w 3/8” Sampling Device On The Side (See TM-641.01)
641.F0 Transformer Vacuum Connection 4” Flanged Butterfly Valve c/w Blanking Plate
641.G0 Transformer Oil Filling Connection c/w Baffle Below Cover (Oil Inlet Valve) 2” NPS
Globe valve c/w Brass Plug
641.N1 Transformer Lower Filter Press Connection (Oil Outlet Valve) 2” NPS Globe Valve
CG POWER SYSTEMS CANADA INC MA120448C REV.3 DATE: 23-Apr-14 PAGE 5 OF 10
641.P0 Transformer Vacuum Sensor Provision, 1” NPS Globe Valve
642.S0 Serveron On-Line Transformer Monitor Mounted On Free Standing Pedestal Top Valve
– 2” Flanged Globe, Bottom Valve 2” Flanged Globe c/w 1/2” Ball Valves (Only
Valves Shown)
* 643.B0 Transformer Conservator Air Bag Type 63” Diameter x160” Long (570 U.S. Gals. At
25 º C) Sloped 1” Towards Drain Valve End
643.BA - Lifting Lugs For Lifting Empty Conservator
643.BB - For Drain 2” NPS Ball Valve c/w Blanking Plate
643.BF - 24” Diameter Manhole For Access To Interior
** 643.BG - 3” NPS Outlet Pipe Projecting 1 ½” Into Conservator Tank c/w 3” NPS Ball Shut-Off
Valve
643.BK - For Air Bleeding Two ½” NPS Ball Valves c/w Blanking Plate
TM-643.BL - Pressure Vacuum Bleeder Valve
** 643.BQ - ¾” NPS Ball Valve In Breather Pipework
643.BR - 1” NPS Ball Valve For Conservator Equalization
* 643.S0 Removable Conservator Support c/w Cross Bracing
644.A0 Weatherproof Control Cabinet 56” Wide x 72’ High x26” Deep. For All Auxiliary
Wiring
*** 644.AB - 10” x 21” Cut-out In Bottom
644.AC - Removable Cut-out Cover (Conduit Entry To Be Drilled On Site)
644.AD - 3-Point Door Locking Arrangement With Provision For Padlocking
*** 644.AE - Safety Wind Stop On Control Cabinet Door, Locking Door @ 140 º Open Position
644.AF - Breathers For Cross Ventilation
CG POWER SYSTEMS CANADA INC MA120448C REV.3 DATE: 23-Apr-14 PAGE 6 OF 10
*** 644.AG - Convenience Outlet, Interior Light And Heater
*** 644.BC Ground Connection Consisting 1/4 ” x 1 1/2” Copper Bar & Common 3/8” - 13 NC
Everdur Stud c/w 2 Connectors One Inside & One Outside
645.AC Cover Handhole 24” Diameter For Access To Core/Clamp Ground Connection & Tank
Interior
645.BA
645.BB
Tank Handhole 20” Diameter For Access To LV Bushing Connections (QTY - 3)
Tank Handhole 20” Diameter For Access To HOXO Bushing Connections (QTY -1)
645.BC Tank Handhole 20” Diameter For Access To TV Bushing Connections (QTY - 2)
645.BD Tank Handhole 24” Diameter For Access To HV Bushing Connections (QTY - 2)
645.CA Tank Handhole 20” Diameter For Access To Linear De-Energized Tap-changer Switch
And Clean Out By Drain Valve
645.CB Tank Handhole 20” Diameter For Access To Linear Switch Drive Shaft Assembly
645.CC Tank Handhole 20” Diameter For Access To Bridge De-energized Tap-changer Switch
*** TM-646.A2 De-energized Tap-changer Bridge Type 300A, CG POWER SYSTEMS CANADA INC
PN 13343411C (5 year Check)
*** TM-646.B1 De-Energized Tap-changer Linear Type 600A, CG POWER SYSTEMS CANADA INC
P/N 16349058 (5 year check)
646.AA - Tap-changer Operating Handle (Linear) c/w Position Indicator And Provision For
Padlocking In Any Position
646.AB - Tap-changer Operation Warning Nameplate
646.AC -Tap-changer Operation Handle (Bridge) c/w Position Indicator And Provision For
Padlocking In Any Position
655.A0 Transformer Lifting Bollards For Lifting Completely Assembled Unit
655.D0 Cover Lifting Lugs
CG POWER SYSTEMS CANADA INC MA120448C REV.3 DATE: 23-Apr-14 PAGE 7 OF 10
655.E0 Transport Tie Down Lugs c/w 2” Diameter Holes
656.B0 Transformer Jacking Step (Jacking Area: 12” x 18”) c/w 3 1/4” Diameter Haulage
Holes For Pulling Transformer In any Direction
657.B0 Skid Type Underbase For Skidding Transformer Along Either Axis
658.B0 Tank Ground Pads (Nema 2 Hole) Located At Base Of Transformer & Located On
Cover Beside H0X0 Turret And Lightning Arresters c/w Two Ground Connectors
659.D0 Core/Clamp Ground Box, Grounded Through 5 kV Bushing And 500 OHM, 25 Watt
Resistor To Ground, Clamp Grounded Through 5 kV Bushing To Ground
660.A0 Current Transformer Terminal Box For Marshalling LV Current Transformer Leads
660.C0 Current Transformer Terminal Box For Marshalling TV Current Transformer Leads
660.E0 Current Transformer Terminal Box For Marshalling HV Current Transformer Leads
660.F0 Current Transformer Terminal Box For Marshalling All Internal Current Transformer
Leads
TM-662.F0 UCL Safety Systems Model 8517412 Non Rotating Base
663.A0 Provision For Mounting Impact Plate Recorder
CG POWER SYSTEMS CANADA INC MA120448C REV.3 DATE: 23-Apr-14 PAGE 8 OF 10
NOTES:
680.00
- Transformer Finish – ANSI 70 Grey
- Transformer Cover Finished With Skid Proof Paint Except Manholes
- Interior Of Tank And Conservator Painted White
- Interior Of Control Box Painted With Anticondensation Compound
- Transformer Suitable For Full Vacuum, Including Bag Type Conservator (See
Transformer Instruction Manual TM-409.70)
- All Bushing Turrets Fitted With Air Bleed Valves And Gas Deflectors
- Dimensions Are In Inches
- All Bushing And Lightning Arresters Are Grey
680.01 - Items Marked Thus * Are Removed For Shipping
- Items Marked Thus ** See Final Page Of Instruction Manual For Site Assembly
Drawings
- Items Marked Thus *** Are Not Indicated On Outline Drawing
-Indicates Centre Of Gravity For Completely Assembled Transformer
-Indicates Centre Of Gravity For Transport
CG POWER SYSTEMS CANADA INC MA120448C REV.3 DATE: 23-Apr-14 PAGE 9 OF 10
680.1A
- Gas Detector Relay Piping On The Cover Must Be Assembled With A Minimum
Slope Upwards Towards The Relay Of 3º
- Transformer Must Be Filled Under Vacuum. Refer To Vacuum Filling Instructions
- Internal Core Ground (And Clamp Ground) Must Be Disconnected Through
(Manhole/Handhole) Item # 645.AC Before Removing The Main Cover
- Before Removing The Main Cover, Oil Must Be Drained From The Tank
- Gas Deflecting Collars Are Used Wherever Gas Might Collect Instead Of Reaching
The Gas Detector Relay
- Transformer Cover Is Welded On And Positively Domed For Gas Collection
- At Any Time Oil Is Lowered Thereby Exposing The Windings To The Atmosphere, Or Completely Drained From Tank, Then Refilling Must Be Per Vacuum Filling
Instructions
- Each Jacking Step Can Support Half Of Mass Of The Transformer When Oil Filled
- When Lifting Completely Assembled Transformer (Without HV & LV Lightning
Arrester Supports, 612.DA, 613.DA), Lifting Spreader Beam Should Be Used To
Avoid Cable Contact With External Accessories
- Handhole No. 645.BA & 645.BD Are Shielded
- All Pipe And Valve Sizes Are American NPT
- Electrical Connections Use The “inch” Diameter. x 12 TPI Series
CG POWER SYSTEMS CANADA INC MA120448C REV.3 DATE: 23-Apr-14 PAGE 10 OF 10
690.01
Approximate Oil Quantities At 25C U.S. Gallons
Main Transformer 12970
Radiators (6 At 86.6 U.S. Gallons each) 520
Conservator 600
Oil For Bleeding Purposes 50
Total Oil 14140
690.03
Transformer Shipped
- Empty – Dry Air System
Revisions Date By Description Approved
01 SEPT-13-13 AT - Revised description on Item 618.05, 624.00, 629.AA, 644.A0
-Added Item 645.BB
SLI
02 DEC-20-13 AT - Revised Item 641.F0, Butterfly was Gate Valve
- Revised Item 643.BB, Blanking Plate was Brass Plug
- Revised Item 643.BK, Blanking Plate was Brass Plug
GS
03 APR-23-14 AT -Revised Item 690.01
MA120448C_REV3.PDF : 20140424122851221
MD120448B_REV4.PDF : 20140424122853231
File details come from the government source that posted it. Updated .