21._Attachment_B_-_Drawings_-_Archer_Sub_KV2A_Transformer_Replacement.pdf

PDF 10 MB Posted

Attached to
Archer Substation kV2A Transformer Replacement Federal contract opportunity
Solicitation number
DE-SOL-0009343
Issued by
Department of Energy Western Area Power Administration

About this file

Attachment B - Drawings

View the file

Other files for this federal contract opportunity

Other files attached to Archer Substation kV2A Transformer Replacement, newest first.
File Type Posted
21._Attendance_Prebid_site_visit.pdf PDF
21._DE-SOL-0009343_AMD_00001.pdf PDF
21._Attachment_G_-_Supplemental_Information.pdf PDF
21._Attachment_C_-_Wage_Determinations.pdf PDF
21._DE-SOL-0009343.pdf PDF
21._Attachment_A_-_Specifications_-_Archer_Sub_KV2A_Transformer_Replacement.pdf PDF
21._IFB_Letter.pdf PDF
21._Attachment_E_-_CRD_DPO.pdf PDF
21._Attachment_F_-_Bid _Performance _Payment_Bonds.pdf PDF
21._Attachment_D_-_Foreign_National_Data_Card.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Attachment B Archer Substation KV2A Transformer Replacement Drawings

DE-SOL-0009343

04 December 2015

ARCHER SUBSTATION

KV2A TRANSFORMER REPLACEMENT

WYOMING

SECTION C

DESCRIPTION/SPECIFICATIONS

Spec. No. 863

PROJECT DRAWINGS

A. GENERAL:

CONSTRUCTION STANDARD DRAWINGS: A complete set of standard drawings are available at https://www.wapa.gov/DoingBusiness/SellingToWestern/Pages/what-western-buys.aspx. Construction drawings are the specification drawings and any additional drawings required for use in construction. The construction drawings will be issued after contract award and may include amendment changes and other details, which make the drawings suitable to use for construction purposes.

PROJECT DRAWINGS: Project drawings included herein are reduced reproductions and are not to scale.

Some project drawings show details of fabrication and other information not a part of the work. Disregard information and details, which are not applicable.

STANDARD DRAWINGS: Where details shown on standard drawings included herein differ from project drawings or text, the details of project drawings or text shall govern.

INFORMATIONAL DRAWINGS: Some project drawings have the words “FOR INFORMATION ONLY” appearing above the title block. These drawings show some information, which may be required for bidding purposes. These drawings do not show items to be furnished or work to be performed.

EXISTING INSTALLATION DRAWINGS: Some project drawings have the words “EXISTING INSTALLATION” appearing above the title block. These drawings show the existing installations prior to modifications and may show some new work to be performed.

REFERENCE DRAWINGS: Reference drawings referred to on project drawings and not included herein, are not necessary for bidding purposes.

CONTRACTOR'S RESPONSIBILITY: Check all drawings and advise Western of any errors or omissions.

B. LIST OF DRAWINGS:

LOCATION MAP:

1. ARH 0015 Rev. D – Location and Vicinity Map

ELECTRICAL:

2. ARH 0001 Rev. M EI – Switching Diagram (Existing Installation)

3. ARH 0001 Rev. N – Switching Diagram

4. ARH 1000 Rev. H EI – General Arrangement Plan (Existing Installation)

5. ARH 1000 Rev. I – General Arrangement Plan

6. ARH 1001 Rev. D EI – Transformer KV2A Area Plan (Existing Installation)

7. ARH 1001 Rev. E – Transformer KV2A Area Plan

8. ARH 1002 Rev. B EI – Transformer KV2A Area Sections (Existing Installation)

9. ARH 1002 Rev. C – Transformer KV2A Area Sections

10. ARH 1004 Rev. A EI – 230KV Bay V2 Section (Existing Installation)

11. ARH 1004 Rev. B – 230KV Bay V2 Section

12. ARH 1008 Rev. E EI – 115KV Bays Y2, Y5 & Y6 Plan (Existing Installation)

13. ARH 1008 Rev. F – 115KV Bays Y2, Y5 & Y6 Plan

14. ARH 1012 Rev. D FIO – Key Grounding Plan (For Information Only)

15. ARH 1021 Rev. B EI – 115KV Bay Y2 Section BB-BB (Existing Installation)

16. ARH 1021 Rev. C – 115KV Bay Y2 Section BB-BB

17. ARH 1026 EI – 230KV Bays V2 Thru V5, & V7 (Existing Installation)

18. ARH 1026 Rev. A – 230KV Bays V2 Thru V5, & V7

19. ARH 1102 Rev. A EI – Equipment and Material Index (Existing Installation)

20. ARH 1102 Rev. B – Equipment and Material Index

21. ARH 1512 EI – 115KV Bays Y2, Y5 & Y6 Grounding Plan (Existing Installation)

22. ARH 1512 Rev. A – 115KV Bays Y2, Y5 & Y6 Grounding Plan

23. ARH 1515 EI – 230KV Bays V2 Thru V5, & V7 Grounding Plan (Existing Installation)

24. ARH 1515 Rev. A – 230KV Bays V2 Thru V5, & V7 Grounding Plan

25. ARH 1517 EI – Transformer KV2A Area Grounding Plan (Existing Installation)

26. ARH 1517 Rev. A – Transformer KV2A Area Grounding Plan

27. ARH 1609 Rev. A EI – Panel DHA2A Electrical Outdoor (Existing Installation)

28. ARH 1609 Rev. B – Panel DHA2A Electrical Outdoor

29. ARH 1610 Rev. A EI – Panels DW1A & DW3A Electrical Outdoor (Existing Installation)

30. ARH 1610 Rev. B – Panels DW1A & DW3A Electrical Outdoor

31. ARH 1611 Rev. C EI – 240V AC 3 Phase 3 Wire Distribution Electrical Outdoor (Existing Installation)

32. ARH 1611 Rev. D – 240V AC 3 Phase 3 Wire Distribution Electrical Outdoor

33. ARH 1712 EI – 115KV Bays Y2, Y5 & Y6 Conduit and Buried Cable Plan (Existing Installation)

34. ARH 1712 Rev. A – 115KV Bays Y2, Y5 & Y6 Conduit and Buried Cable Plan

35. ARH 1715 EI – 230KV Bays V2 Thru V5, & V7 Conduit and Buried Cable Plan (Existing Installation)

36. ARH 1715 Rev. A – 230KV Bays V2 Thru V5, & V7 Conduit and Buried Cable Plan

37. ARH 1717 EI – Transformer KV2A Area Conduit and Buried Cable Plan (Existing Installation)

38. ARH 1717 Rev. A – Transformer KV2A Area Conduit and Buried Cable Plan

PROJECT DRAWINGS

FOUNDATION AND STRUCTURAL DRAWING INDEX:

39. ARH 2072-1 Rev. B – Foundation/Structural Data and Drawings Index (Sheet 1 of 2)

40. ARH 2072-2 Rev. A – Foundation/Structural Data and Drawings Index (Sheet 2 of 2)

SITEWORK:

41. ARH 2001 Rev. F EI – Foundation General Plan (Existing Installation)

42. ARH 2001 Rev. G – Foundation General Plan

43. ARH 2002 Rev. I EI – Foundation Plan 230KV Area (Existing Installation)

44. ARH 2002-1 – Foundation Plan Transformer/Reactor Area (Sheet 1 of 3)

45. ARH 2002-2 – Foundation Plan 230KV Area (Sheet 2 of 3)

46. ARH 2003 Rev. B EI – Foundation Plan 115KV Area (Existing Installation)

47. ARH 2003-1 – Foundation Plan 115KV Area (Sheet 1 of 2)

CONCRETE:

48. ARH 2006 Rev. B – Foundations Outline & Reinforcement

49. ARH 2007 Rev. B – Foundations Outline & Reinforcement

50. ARH 2008 Rev. A – Foundations Outline & Reinforcement

51. ARH 2025 Rev. C – Foundations Outline & Reinforcement

52. ARH 2302 – Foundations Outline & Reinforcement

53. ARH 2303 – Foundations Outline & Reinforcement

54. ARH 2304 – Foundations Outline & Reinforcement

SUBSTATION STEEL:

55. ARH 2010 Rev. F – Steel Structures Embedded Material

56. ARH 2021 Rev. A EI – Steel Structure Bus Frame and Poles (Existing Installation)

57. ARH 2550 Rev. A – Anchor Bolts

58. ARH 2551 – Embedded Material

59. ARH 2610 – CCVT Steel Structure

60. ARH 2926 – Equipment Cabinet Platforms Steel Design and Details

GEOLOGY:

61. ARH 2000 Rev. B EI – Grading and Plot Plan (Existing Installation)

62. ARH 8000 Rev. A EI – Logs of Exploration (Existing Installation)

CONTROLS:

63. ARH T610 – Control Cable List

64. ARH 4000-1 Rev. A FIO – Service Building Layout (For Information Only)

FOR INFORMATION ONLY

FOR INFORMATION ONLY

lampman Text Box

Cover Page
Drawing List
arh_0015d
arh_0001m_ei
arh_0001n
arh_1000h_ei
arh_1000i
arh_1001d_ei
arh_1001e
arh_1002b_ei
arh_1002c
arh_1004a_ei
arh_1004b
arh_1008e_ei
arh_1008f
arh_1012d_fio
arh_1021b_ei
arh_1021c
arh_1026_ei
arh_1026a
arh_1102a_ei
arh_1102b
arh_1512_ei
arh_1512a
arh_1515_ei
arh_1515a
arh_1517_ei
arh_1517a
arh_1609a_ei
arh_1609b
arh_1610a_ei
arh_1610b
arh_1611c_ei
arh_1611d
arh_1712_ei
arh_1712a
arh_1715_ei
arh_1715a
arh_1717_ei
arh_1717a
arh_2072_1b
arh_2072_2a
arh_2001f_ei
arh_2001g
arh_2002i_ei
arh_2002_1
arh_2002_2
pv_2003b_ei
arh_2003_1
arh_2006b
arh_2007b
arh_2008a
arh_2025c
arh_2302
arh_2303
arh_2304
arh_2010f
arh_2021a_ei
arh_2550a
arh_2551
arh_2610
arh_2926
arh_2000b_ei
arh_8000a_ei
arh_t610
arh_4000_1a_fio