Amend_002_SF30.pdf
PDF 40 KB Posted
- Attached to
- Construct VT Hanlon Substation, Stage 01, in South Dakota Federal contract opportunity
- Solicitation number
- DE-SOL-0007930
About this file
Amendment 0002 SF30
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Amendment_003.pdf | ||
| Amend_002_Bidding_Schedule.pdf | ||
| Amend_002_Project_Specifications.pdf | ||
| VH_Contractor_and_internal_questions_and_answers.docx | DOCX document | |
| Amend_002_Project_Drawings.pdf | ||
| 21._Amendment_0001.pdf | ||
| 21._Prospective_Bidders_Letter.pdf | ||
| Project_Specifications.pdf | ||
| Contract_Clauses_and_Bid_Schedule.pdf | ||
| Project_Drawings.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT
1. CONTRACT ID CODE PAGE OF PAGES
DE-SOL-0007930 1 3
2. AMENDMENT/MODIFICATION NO. 3. EFFECTIVE DATE 4. REQUISITION/PURCHASE REQ. NO 5. PROJECT NO. (If applicable)
002 July 24, 2015 N/A 15WC112847-834
6. ISSUED BY CODE 7. ADMINISTERED BY (If other than Item 6) CODE
U.S. DEPARTMENT OF ENERGY
Western Area Power Administration
200 4TH ST SW
Huron, SD 57350-2474
Jonathan Dittmer
(605) 353-2641
8. NAME AND ADDRESS OF CONTRACTOR (No., street, county, State and ZIP Code) (√) 9A. AMENDMENT OF SOLICITATION NO.
ALL PROSPECTIVE BIDDERS
X
DE-SOL-0007930
9B. DATED (SEE ITEM 11)
June 22, 2015
10A. MODIFICATION OF CONTRACT/ORDER NO.
10B. DATED (SEE ITEM 13)
CODE FACILITY CODE
11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS
The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offers is extended, is not extended. Offers must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended, by one of the following methods:
(a) By completing Items 8 and 15, and returning 1 copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted;
or (c) By separate letter or telegram which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN REJECTION OFO YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by telegram or letter, provided each telegram or letter makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.
12. ACCOUNTING AND APPROPRIATION DATA (If required)
13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS,
IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.
(√) A. THIS CHANGE ORDER IS ISSUED PURSUANT TO : (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE CONTRACT
ORDER NO. IN ITEM 10A.
B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation date, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(b).
C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:
D. OTHER (Specify type of modification and authority)
E. IMPORTANT: Contractor is not, is required to sign this document and return copies to the issuing office.
14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)
VT Hanlon Substation Stage 01
South Dakota
(Continued on next page)
Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.
15A. NAME AND TITLE OF SIGNER (Type or print) 16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)
15B. CONTRACTOR/OFFEROR 15C. DATE SIGNED 16B. UNITED STATES OF AMERICA 16C. DATE SIGNED
BY
(Signature of person authorized to sign) (Signature of Contracting Officer)
NSN 7540-01-152-8070
PREVIOUS EDITION UNUSABLE
30-105 STANDARD FORM 30 (REV. 10-83)
Prescribed by GSA
FAR (48 CFR) 53.243
DEPARTMENT OF ENERGY
WESTERN AREA POWER ADMINISTRATION
VT Hanlon Substation Solicitation No. DE-SOL-0007930 Stage 01, South Dakota Amendment No. 002, page 2 of 3
The purpose of this amendment is to incorporate necessary changes in the solicitation prior to receipt of bids as follows:
1. The date and time set for receipt of bids is hereby changed to August 12, 2015 2:00 PM local time at place of bid opening.
2. In Section B, Supplies or Service and Prices, ensure the following changes are made:
Remove pages Insert attached revised pages Added or changed
All All Replace Entire Bidding Schedule
3. In Section C, Description/Specifications, Project Specifications, ensure the following pages are deleted and the attached revised pages are substituted therefore:
Remove pages Insert attached revised pages Added or changed
All All Replace Entire Specifications
For convenience, essential changes on the revised specifications pages are indicated by a vertical line in the margin. However, all portions of the revised specifications pages shall apply whether changes have or have not been indicated.
4. In Section C, Description/Specifications, Project Drawings, ensure the following drawings are deleted and the attached revised drawings are substituted therefore:
Existing Drawing Insert Revised or New Drawing Added or Changed
Drawing Index Drawing Index Replace Entire Index
2. VH 0001-1 VH 0001-1 Rev. A Revised LME
3. VH 0001-2 VH 0001-2 Rev. A Revised LME and Resistor Values
4. VH 1000 VH 1000 Rev. A Revised LME
6. VH 1011 VH 1011 Rev. A Revised Bus Fittings
9. VH 1040 VH 1040 Rev. A Revised Bus Fittings
10. VH 1050 VH 1050 Rev. B Removed RW19A and VW19A
45. VH 1500 VH 1500 Rev. A Revised LME
51. VH 1550 VH 1550 Rev. A Revised LME
52. VH 1600 VH 1600 Rev. A Added LME Breakers 55a. VH 1612 New 55b. VH 1614 New 55c. VH 1616 New
56. VH 1700 VH 1700 Rev. A Revised LME
58. VH 1711 VH 1711 Rev A. Added Conduit Size
59. VH 1725 VH 1725 Rev. A Added DWA Conduit
DEPARTMENT OF ENERGY
WESTERN AREA POWER ADMINISTRATION
VT Hanlon Substation Solicitation No. DE-SOL-0007930 Stage 01, South Dakota Amendment No. 002, page 3 of 3
Remove drawing Insert attached revised drawing Added or Changed
62. VH 1750 VH 1750 Rev. A Revised LME
65. VH 2050 VH 2050 Rev. B Add Existing Fence Line 65a. VH T017 New
67. VH 2052 VH 2052 Rev. A Updated 12” HDPE
70. VH 2000 VH 2000 Rev. A Added Structures
71. VH 2150 VH 2150 Rev. A Revised Foundation Plan
77. VH 2205 VH 2205 Rev. A Added Structures
87. VH 2306 VH 2306 Rev. A Revised Note
88. VH 2307 VH 2307 Rev. A Revised Note
89. VH 2308 VH 2308 Rev. A Revised Note
90. VH 2309 VH 2309 Rev. A Revised Note
91. VH 2310 VH 2310 Rev. A Revised Note
92. VH 2311 VH 2311 Rev. A Revised Note
93. VH 2312 VH 2312 Rev. A Added Conduit 94a. VH 2314 Rev. A New 94b. VH 2315 Rev. A New 94c. VH 2316 Rev. A New
129. VH 3201 VH 3201 Rev. A Moved Equipment Slab
130. VH 3202 VH 3202 Rev. A Added Blocking
137. VH 3000 Delete 137a. VH 3000-1 New 137b. VH 3000-2 New
138. VH 3001 VH 3001 Rev. A Deleted Duct Openings
142. VH 3005 VH 3005 Rev. A Deleted Duct Detail
144. VH 3300 VH 3300 Rev. A HVAC Revisions
145. VH 3301 VH 3301 Rev. A HVAC Revisions
146. VH 3302 VH 3302 Rev. A Schedule Revisions
147. VH 3303 VH 3303 Rev. A Revised Notes and Diagram
148. VH 3304 VH 3304 Rev. A Revised Notes and Detail
149. VH 3400 VH 3400 Rev. A System Revisions
150. VH 3401 VH 3401 Rev. A System Revisions
151. VH 3402 VH 3402 Rev. A System Revisions
152. VH 3403 VH 3403 Rev. A System Revisions
153. VH 3404 VH 3404 Rev. A System Revisions
154. VH 3405 VH 3405 Rev. A System Revisions
155. VH 4000 VH 4000 Rev. A System Revisions
156. VH T600-1 VH T600-1 Rev. A Added Cable for Breakers
157. VH T600-2 VH T600-2 Rev. A Added Cable for Breakers
158. VH 6000 Delete 158a. VH 6000-1 New 158b. VH 6000-2 New 161a. FT-SF D 2005 Rev. A New 161b. FT-SF D 2006 Rev. A New 161c. FT-SF D 2007 Rev. A New 161d. FT-SF D 2008 Rev. A New 161e. FT-SF D 2009 Rev. A New
5. If you have given your copy of the specifications to someone else, please forward this amendment also.
| AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT |
| DE-SOL-0007930 |
| 200 4TH ST SW |