CS502.pdf
PDF 241 KB Posted
- Attached to
- Flightline CT Ramp Repairs 1031 funds
- Solicitation number
- SRC0000029760
- Issued by
- Ohio
About this file
This document is a construction engineering drawing set (CS502) for the 180th Fighter Wing at Toledo Express Airport in Ohio, specifically detailing airfield pavement and infrastructure design for the ANG (Air National Guard) ACA Shelters project. The technical drawings provide comprehensive specifications for reinforced concrete pavement, including detailed schematics for airfield apron slabs, dowel bar assemblies, taxilane markings, and restricted area warnings. The drawings include precise technical specifications for concrete slab reinforcement, including steel rebar and welded wire fabric placement, dowel bar sizing and positioning, joint configurations, and specific requirements for structures around airfield pavements.
The technical drawings are part of a civil engineering set prepared by Burns & McDonnell Engineering Company, dated February 12, 2018, with revisions noted. The documents include multiple detailed views showing pavement thickness, steel reinforcement requirements, dowel bar placement, expansion joint details, and specific markings for taxilanes and restricted areas. The design appears to be for a military infrastructure project involving concrete pavement construction, with particular attention to structural integrity, load-bearing capacity, and precise engineering standards typical of critical airport and military facility infrastructure.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
1/2" WIRE SPACING
OR 3" MAX.
NOTES:
1. SHADED SLABS INDICATED ON THE JOINT LAYOUT PLAN SHALL BE REINFORCED WITH
STEEL REBAR OR WELDED WIRE FABRIC OF THE SIZES SHOWN. OTHER WELDED WIRE
FABRIC SIZES MAY BE USED PROVIDED THE STEEL AREA (SQUARE INCHES PER FOOT)
IN THE LONGITUDINAL AND TRANSVERSE DIRECTIONS IS EQUAL TO OR EXCEEDS
THAT SHOWN IN TABLE 1. SEE DETAIL A1, THIS SHEET, FOR REINFORCEMENT LAYOUT
AROUND STRUCTURES ON THE AIRFIELD APRON.
2. WELDED WIRE FABRIC OR REBAR SHALL BE OVERLAPPED FOR A DISTANCE EQUAL TO
AT LEAST ONE SPACING OF THE WIRE IN THE FABRIC OR 32 WIRE DIAMETERS,
WHICHEVER IS GREATER. THE WIRES IN THE LAP SHALL BE WIRED OR OTHERWISE
SECURELY FASTENED TO PREVENT SEPARATION DURING CONCRETE PLACEMENT.
3. DEFORMED STEEL BARS WILL BE OVERLAPPED FOR AN DISTANCE OF AT LEAST 24
BAR DIAMETERS, MEASURED FROM THE TIP OF ONE BAR TO THE TIP OF THE OTHER
BAR. THE LAPPED BARS WILL BE WIRED OR OTHERWISE SECURELY FASTENED TO
PREVENT SEPARATION DURING CONCRETE PLACEMENT.
TABLE 1
PAVEMENT
THICKNESS
(INCHES)
MINIMUM REQUIRED
AREA OF STEEL
(SQ. INCHES/FOOT)
WELDED WIRE
FABRIC
12-17 0.102 6x6-W5.5xW5.5
T/
T
PAVEMENT
JOINT OR EDGE
SHADED SLABS ON JOINT PLAN ARE
REINFORCED. SEE TABLE FOR SIZE
AND SPACING OF REINFORCEMENT.
T/4 + 1"
DOWEL BAR.
SEE DETAIL H6 THIS
SHEET TABLE 2
W (APRON PANEL WIDTH)
W (A
PR
O
N P
AN
EL
W
ID
TH
NOTES:
1. USE FOR ALL CONCRETE SLABS
WITH "R" THAT CONTAIN
STRUCTURES. SEE DETAIL C1 THIS
SHEET FOR REINFORCEMENT FOR
CONCRETE PANELS WITHOUT
STRUCTURES AND TABLE 1 FOR
REBAR OR WWF.
2. WELDED WIRE FABRIC SHALL BE
OVERLAPPED FOR A DISTANCE
EQUAL TO AT LEAST ONE SPACING
OF THE WIRE IN THE FABRIC OR 32
WIRE DIAMETERS, WHICHEVER IS
GREATER. THE WIRES IN THE LAP
SHALL BE WIRED OR OTHERWISE
SECURELY FASTENED TO PREVENT
SEPARATION DURING CONCRETE
PLACEMENT.
3. PROVIDE 3" SEPARATION BETWEEN
REINFORCEMENT AND EDGE OF
SLAB.
CL
#5 BARS @ 12" O.C.
T&B, EACH WAY FOR
FUEL PIT SLABS ONLY
GROUND ROD APPROX.
3.00' FROM FUEL PIT LID
(SEE ELECTRICAL SHEETS)
2 #5 BARS x 48" LONG @ 6" O.C.
T&B @ RE-ENTRANT CORNERS
(TYP.) SEE NOTES 1 AND 2. ALL
SLABS WITH STRUCTURES.
STRUCTURE
OR FUEL
HYDRANT PIT
CL
L
0.
6L
M
IN
0.6L
MIN.
THICKNESS
OF SLAB (T) DIAM LENGTH SPACING
12"-15.5" 1-1/4" 20" 15"
DOWEL BAR SIZE -TABLE 2
NOTES:
1. SEE SPECIFICATION SECTION 32 13 11 CONCRETE PAVEMENT FOR AIRFIELDS AND OTHER HEAVY DUTY
PAVEMENTS FOR ADDITIONAL DOWEL BAR SPACING REQUIREMENTS.
2. WHEN DOWELED JOINTS ARE REQUIRED BETWEEN PAVEMENTS OF DIFFERING THICKNESS, THE DOWELS SHALL BE SIZED FOR THE THINNER SECTION, AND PLACED AT T/2 ± D/2 OF THE THINNER
PAVEMENT.
DOWELS WELDED
ALTERNATELY TO
TOP SPACER BARS0.362" DIA "VEE" LEG
CHAIRS WELDED AT ALL
INTERSECTIONS TO TOP
AND BOTTOM SPACER BAR
0.177" DIA. SPREADER WIRES
WELDED TO TOP SPACER
BARS 3 PER ASSEMBLY TO
BE CLIPPED AFTER STAKING
0.362" DIA BOTTOM
SPACER BARS WELDED TO
LEG CHAIRS - 2 PER ASSEMBLY
0.362" DIA TOP SPACER
BARS WELDED TO LEG
CHAIRS - 2 PER ASSEMBLY
DOWEL
JOINT
DOWEL BAR ASSEMBLY
SHALL BE FASTENED TO
BASE COURSE PRIOR TO
PAVING TO PREVENT
FLOATING DURING PAVING
OPERATIONS
L TAXIWAY
6"
C
6" CONTINUOUS YELLOW
REFLECTORIZED PAINT
LOCATION
POINT - SEE
SITE PLANS
D1 DOWEL BAR ASSEMBLY
SCALE: NTS
A1 REINFORCEMENT AROUND STURCTURES
SCALE: NTS
TYPICAL AIRFIELD APRON SLAB
D6 TAXILANE CENTERLINE
SCALE: NTS
G1 REINFORCED CONCRETE PAVEMENT
SCALE: NTX
H6 DOWEL BAR LOCATION AND SIZES
SCALE: NTS
6"
D8 TAXILANE EDGE MARKING
SCALE: NTS
APRON SHOULDER
EDGE OF APRON FULL
STRENGTH PAVEMENT
MIN
CONCRETE
1" 1"
3' -1
1" 3'
-0
3"
12"
BITUMINOUS JOINT
FILLER (CONCRETE
PAVEMENT ONLY)
4" DIA. GALVANIZED
STEEL PIPE. PAINTED
WITH SAFETY YELLOW
PAINT.
FINISH GRADE
OR ASPHALT PAVEMENT
PCC
PAVEMENT
SECTION
EXPANSION
JOINT H6/CS501
B5 TYPICAL BOLLARD
SCALE: NTS
C8 RESTRICTED AREA WARNING
SCALE: NTS
12" OR MATCH EXISTING
CONTINUOUS RED
REFLECTORIZED
PAING
H9 PAVMENT MARKING
SCALE: NTS
RED RESTRICTION LINE
NOTES:
1. PLACE RESTRICTED AREA WARNING
SIGNS AT INTERVALS OF 100 FEET
CENTERED ON THE VERTICAL
PLANE. WHERE BOUNDARIES MAKE
ABRUPT CHANGES IN DIRECTION
AND AT ENTRY CONTROL POINTS
TO THE RESTRICTED AREA.
2. COORDINATE LOCATIONS WITH
SECURITY FORCES PRIOR TO
PLACEMENT. STENCILS WILL BE
PROVIDED BY SECURITY FORCES.
6" CONTINUOUS YELLOW
REFLECTORIZED PAINT
Sc al e Fo r M ic ro fil m in g In ch es
M illi m et er s date detailed checkeddesigned ofsheet sheets project contract rev.drawing file
no. date descriptionby ckd
J
H
G
F
E
D
C
B
A
C O
PY
R
IG
H
T
BU
R
N S
M cD O
N N
EL
L
EN
G
IN
EE
R
IN
G C
O M
PA
N
Y, IN
C
2/
/2
9:
:1
AM
180TH FIGHTER WING
OHIO AIR NATIONAL GUARD
TOLEDO EXPRESS AIRPORT
SWANTON, OHIO
9400 WARD PARKWAY
KANSAS CITY, MO 64114
(816) 333-9400
REVISIONS
K
1 1098765432
WYTD079031 W9133L-15-D-0003-9M03
SITE DETAILS SHEET 3 OF 3
CS502
SITE DETAILS SHEET 3 OF 3
02/12/18 C. FRANZEN
A. DORMAN C. STEWART
\\BMCD\DFS\CLIENTS\ANF\USNGB\ANG\OH\102134_OHANGALRTSHLTB\DESIGN\CIVIL\SHEETS\102134CS500.DWG 1/4/2019 1:42 PM CFRANZEN
ISSUED FOR
CONSTRUCTION
ABDCWF01/07/19
File details come from the government source that posted it. Updated .