Construction Documents.pdf

PDF 6 MB Posted

Attached to
1111-24P General Contractor for Radiology Lab Remodel State and local contract opportunity
Solicitation number
1111--24P
Issued by
Eagle County, Colorado

About this file

These Construction Documents detail a renovation project for Colorado Mountain College's Edwards Campus located at 150 Miller Ranch Road in Edwards, Colorado. The project involves renovating approximately 1,953 square feet of interior space, specifically transforming an existing classroom into a new Radiology Lab. The scope includes a comprehensive renovation of the space, replacement of existing systems such as HVAC, information technology, electrical, fire suppression and alarm, and plumbing systems, along with new interior finishes. The project will also include a 1,257 square foot fully sprinklered and detected addition on the east side of the existing Apparatus Bay, located on the south side of the academic building.

The renovation is designed to accommodate a new Dental Hygiene program and includes modifications to the first floor, with a total building square footage of 69,764 GSF after completion. The construction type is classified as Type II-B, fully sprinklered, with the project adhering to the 2021 International Building Code and various other applicable codes and standards. The estimated cost and funding sources are not explicitly detailed in the documents, but the project involves multiple design disciplines including architectural, mechanical, electrical, and medical equipment considerations. The documents are prepared by Hord Coplan Macht, Inc. and are dated November 5, 2024, and marked as "Issue for Bidding and Construction".

View the file

Other files for this state and local contract opportunity

Other files attached to 1111-24P General Contractor for Radiology Lab Remodel, newest first.
File Type Posted
CMC Edwards Rad Shielding Report-Update final.pdf PDF
Project Manual.pdf PDF
1111-24P General Contractor for Radiology Lab Remodel.pdf PDF
Bid Sheet.xlsx XLSX spreadsheet
1111-24P Addendum 001.docx DOCX document

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

A/C AIR CONDITIONING

ABV ABOVE

ACST ACOUSTIC, ACOUSTICAL

ADA AMERICANS WITH DISABILITIES ACT

ADJ ADJUSTABLE

ADJT ADJACENT

AFF ABOVE FINISH FLOOR

ALT ALTERNATE

ALUM ALUMINUM

ANOD ANODIZED

ARCH ARCHITECT, ARCHITECTURAL

ASPH ASPHALT

ASSY ASSEMBLY

AUTO AUTOMATIC

BATT BATT INSULATION

BKR BACKER ROD

BD BOARD

BF BOTH FACES

BLDG BUILDING

BLKG BLOCKING

BLW BELOW

BM BEAM

BN BULLNOSE

BOD BASIS OF DESIGN

BOS BOTTOM OF STEEL

BOT BOTTOM

BRG BEARING

BS BOTH SIDES

BSMT BASEMENT

BTWN BETWEEN

BUR BUILT UP ROOFING

BW BOTH WAYS

BYND BEYOND

CG CORNER GUARD

CIP CAST IN PLACE

CJ CONTROL JOINT

CL CENTER LINE

CLG CEILING

CLST CLOSET

CLR CLEAR

CLRM CLASSROOM

CMU CONCRETE MASONRY UNIT

CO COMPANY

COL COLUMN

CONC CONCRETE

CONT CONTINUE

CONTR CONTRACTOR

COORDCOORDINATE

CORR CORRIDOR

CPT CARPET

CRS COURSE(S)

CSWK CASEWORK

CT CERAMIC TILE

CTR CENTER

CTV CABLE TELEVISION

CU CUBIC

CUH CABINET UNIT HEATER

CW COLD WATER PIPING

DBL DOUBLE

DEPT DEPARTMENT

DTL DETAIL

DF DRINKING FOUNTAIN

DIA DIAMETER

DIM DIMENSION

DISP DISPENSER

DL DEAD LOAD

DMPF DAMPROOFING

DN DOWN

DR DOOR

DS DOWNSPOUT

DW DISHWASHER

DWG DRAWING

E EAST

EA EACH

ED EDUCATION

EJ EXPANSION JOINT

EL ELEVATION

ELEC ELECTRICAL

ELEV ELEVATOR

ENCL ENCLOSURE

ENGR ENGINEER

EPDM ETHYLENE PROPYLENE DIENE MONOMER

EQ EQUAL

EQUIP EQUIPMENT

EWC ELECTRIC WATER COOLER

EWH ELECTRIC WATER HEATER

EXC EXCAVATE

EXIST EXISTING

EF EXHAUST FAN

EXP EXPANSION

EXT EXTERIOR

A

B

C

D

E

F/F FACE TO FACE

FA FIRE ALARM

FAAP FIRE ALARM ANNUNICATOR PANEL

FACP FIRE ALARM CONTROL PANEL

FCO FLOOR CLEAN OUT

FD FLOOR DRAIN

FDC FIRE DEPARTMENT CONNECTION

FDTN FOUNDATION

FE FIRE EXTINGUISHER

FEC FIRE EXTINGUISHER CABINET

FF FINISH FACE

FFE FINISH FLOOR ELEVATION

FH FIRE HYDRANT

FHC FIRE HOSE CABINET

FIN FINISH

FIXT FIXTURE

FLR FLOOR

FOF FACE OF FINISH

FOS FACE OF STUD

FR FRAME

FRP FIBERGLASS REINFORCED PLASTIC

FRTW FIRE RETARDANT TREATED WOOD

FT FOOT

FUR FURRING

GA GAGE

GALV GALVANIZED

GB GRAB BAR

GL GLASS

GLU LAM GLUED LAMINATED WOOD

GLAZ GLAZING

GYP GYPSUM

HB HOSE BIB

HDR HEADER

HDW HARDWARE

HDWD HARDWOOD

HM HOLLOW METAL

HDRL HANDRAIL

HORIZ HORIZONTAL

HP HORSEPOWER

HT HEIGHT

HVAC HEATING VENTILATING & AIR CONDITIONING

HW HOT WATER

HYD HYDRANT

ID INSIDE DIAMETER

INCL INCLUDED

INSUL INSULATION

INT INTERIOR

JST JOIST

K KELVIN

kW KILOWATT

L ANGLE

LAV LAVATORY

LBR LUMBER

LF LINEAR FEET (FOOT)

LIB LIBRARY

LINO LINOLEUM

LKR LOCKER

LL LIVE LOAD

LLH LONG LEG HORIZONTAL

LLV LONG LEG VERTICAL

LT LIGHT

LVR LOUVER

MAX MAXIMUM

MECH MECHANICAL

MEMB MEMBRANE

MFD MANUFACTURED

MFR MANUFACTURER

MIN MINIMUM

MIRR MIRROR

MISC MISCELLANEOUS

MLDG MOLDING

MO MASONRY OPENING

MTD MOUNTED

MTL METAL

NA NOT APPLICABLE

NONCOM NONCOMBUSTIBLE

NIC NOT IN CONTRACT

NO NUMBER

NOM NOMINAL

NRC NOISE REDUCTION COEFFICIENT

NTS NOT TO SCALE

OA OVERALL

OC ON CENTER

OD OUTSIDE DIAMETER

OF/CI OWNER FURNISHED/CONTRACTOR INSTALLED

OF/OI OWNER FURNISHED/OWNER INSTALLED

OH OVERHEAD

OPP OPPOSITE

OPNG OPENING

ORD OVERFLOW ROOF DRAIN

F

PBD PARTICLEBOARD

PCF POUNDS PER CUBIC FOOT

PCP PORTLAND CEMENT PLASTER

PLAM PLASTIC LAMINATE

PLBG PLUMBING

PLYWD PLYWOOD

PREFAB PREFABRICATED

PREFINPREFINISHED

PRKG PARKING

PSF POUNDS PER SQUARE FOOT

PSI POUNDS PER SQUARE INCH

PT PAINT

PTD PAPER TOWEL DISPENSER

PTN PARTITION

PVC POLYVINYL CHLORIDE

QT QUARRY TILE

QTB QUARRY TILE BASE

QTY QUANTITY

R RADIUS, RISER

R-__ THERMAL RESISTANCE

RA RETURN AIR

RB RUBBER BASE

RD ROOF DRAIN

RDL ROOF DRAIN LEADER

RE: REFER TO

REINF REINFORCE

REQD REQUIRED

REV REVISION

RM ROOM

RO ROUGH OPENING

RPM REVOLUTIONS PRE MINUTE

RTU ROOF TOP UNIT

SECT SECTION

SF SQUARE FOOT, FEET

SA SUPPLY AIR

SAT SUSPENDED ACOUSTICAL TILE

SB SPLASH BLOCK

SCHED SCHEDULE

SCP SCUPPER

SD SOAP DISPENSER

SOG SLAB ON GRADE

SGFT STRUCTURAL GLAZED FACED TILE

SHT SHEET

SHTHG SHEATHING

SIM SIMILAR

SJ SLIP JOINT

SLDG SLIDING

SLNT SEALANT

SND SANITARY NAPKIN DISPENSER

SNDU SANITARY NAPKIN DISPOSAL UNIT

SPEC SPECIFICATION

SQ SQUARE

SST STAINLESS STEEL

STC SOUND TRANSMISSION CLASS

STD STANDARD

STL STEEL

STOR STORAGE

STRUCT STRUCTURAL

SUSP SUSPEND(ED)

SYMM SYMMETRICAL

SYS SYSTEM

T&G TONGUE & GROOVE

TD TOWEL DISPENSER

TEL TELEPHONE

THK THICKNESS

TO TOP OF

TOC TOP OF CONCRETE

TOM TOP OF MASONRY

TOS TOP OF STEEL

TOW TOP OF WALL

TPD TOILET PAPER DISPENSER

TYP TYPICAL

UNFIN UNFINISHED

UON UNLESS OTHERWISE NOTED

UR URINAL

VAR VARIES, VARIABLE

VCT VINYL COMPOSITION TILE

VERT VERTICAL

VEST VESTIBULE

VIF VERIFY IN FIELD

VTR VENT THROUGH ROOF

VWC VINYL WALL COVERING

W WEST

W/ WITH

W/O WITHOUT

WB WOOD BASE

WBL WOOD BLOCKING

WC WATER CLOSET

WCO WALL CLEAN OUT

WD WOOD

WF WIDE FLANGE

WP WORKING POINT

WSCT WAINSCOT

WWF WELDED WIRE FABRIC

WNDW WINDOW

YD YARD

P

G

H

I

J

K

L

M

N

O

Q

R

S

T

U

V

W

Y

CONCRETE

CMU

PLYWOOD

GYPSUM

STEEL

BRICK

ROUGH LUMBER

FINISH LUMBER

RIGID INSULATION

BATT INSULATION

DETAIL NUMBER

SHEET

NUMBER

EXTERIOR ELEVATION

DETAIL NUMBER

BUILDING SECTION

SHEET

NUMBER

DETAIL NUMBER

WALL SECTION

SHEET

NUMBER DETAIL NUMBER

INTERIOR ELEVATION

SHEET

NUMBER

WINDOW TAG

DOOR TAG

KEYNOTE TAG

PARTITION TAG

REVISION TAG

DETAIL CALLOUT

DETAIL NUMBER

SHEET NUMBER

A-XXX

XX

XX

XX XX

A-XXX

XX

A-XXX

XX

A-XXX

XX

A-XXX

XX

A

054000.D01

No. Date Revision

© Hord Coplan Macht, Inc.

ARCHITECTURE

LANDSCAPE ARCHITECTURE

PLANNING

INTERIOR DESIGN

Drawing

Drawn By

Date (YYYY/MM/DD)

ARCHITECT

Project Number

Project Name

A

B

C

D

E

654321

Checked By

M/E/P ENGINEER

Cator Ruma & Associates Co 896 Tabor St #1 Lakewood, CO 80401

p. 303. 232. 6200

Hord Coplan Macht, Inc.

1800 Wazee Street, Suite 450 Denver, CO 80202

p. 303.607.0977

f. 303.607.0767

A u to d e s k D o c s /2

C

M C

E d w a rd s R a d io lo g y /2

C

M C

E d w a rd s R a d io lo g y

R .r v t

/5

/2

:0 :1

P

M

E D

W A

R D

S R

A D

IO

L O

G Y

L A

B R

E N

O V

A T

IO

N

M ill e r

R a n c h R d E d w a rd s C

O

ISSUE FOR BIDDING AND

CONSTRUCTION

2024/11/05

Checker

C O

L O

R A

D O

M O

U N

T A

IN

C

O L L E

G E

224089

G-002

GENERAL INFORMATION AND

SHEET INDEX

EDWARDS RADIOLOGY LAB

RENOVATION

Author

INDEX ARCHITECTURAL SHEETS

AD-111 DEMOLITION FOOR PLAN AND REFLECTED CEILING PLAN

A-110 OVERALL FIRST FLOOR PLAN

A-111 FIRST FLOOR PLAN

A-410 TYPICAL MOUNTING HEIGHTS, ASSEMBLY AND PARTITION TYPES

INDEX GENERAL SHEETS

G-002 GENERAL INFORMATION AND SHEET INDEX

G-003 LIFE SAFETY PLANS - FIRST FLOOR

G-004 LIFE SAFETY PLANS -SECOND FLOOR

SHEET INDEX

ARCHITECTURAL ABBREVIATIONS

PROJECT TEAM ARCHITECTURAL LEGEND

VICINITY MAP

ARCHITECT:

Hord Coplan Macht 1800 Wazee St., Suite 450 Denver, CO. 80202

Ph: 303-607-0977 Fax: 303-607-0767 URL: www.hcm2.com

MECHANICAL:

Cator Ruma & Associates Co.

896 Tabor St. #1 Lakewood, CO 80401

Ph: 303-232-6200 URL: www.catorruma.com

EDWARDS RADIOLOGY LAB RENOVATION

150 Miller Ranch Rd Edwards, CO 81632

ISSUE FOR BIDDING AND CONSTRUCTION

2024/11/05

SITE

TECHNOLOGY:

Cator Ruma & Associates Co.

896 Tabor St. #1 Lakewood, CO 80401

Ph: 303-232-6200 URL: www.catorruma.com

INDEX MECHANICAL SHEETS

M-001 MECHANICALAND PLUMBING LEGENDS AND NOTES

M-111 FIRST FLOOR MECHANICAL PLANS

INDEX ELECTRICAL SHEETS

E-001 ELECTRICAL LEGENDS AND NOTES

E-011 ELECTRICAL ONE LINE DIAGRAM

E-111 FIRST FLOOR ELECTRICAL PLANS

E-401 ELECTRICAL DETAILS

ED-111 FIRST FLOOR ELECTRICAL DEMOLITION PLANS

DEL MEDICAL

ME-100 DEL MEDICAL DRAWINGS

DEL MEDICAL:

BLOOMINGDALE, ILLINOIS

T: 847.288.7067 www.delmedical.com rdetroit Image rdetroit Text Box 11/05/2024

CODE INFO

PROJECT NAME:

PROJECT DESCRIPTION:

THE COLORADO MOUNTAIN COLLEGE AT EDWARDS, CO ADDITION AND

RENOVATION PROJECT IS LOCATED AT 150 MILLER RANCH RD., EDWARDS, CO

81632. THIS PROJECT INCLUDES AN ADDITION AND RENOVATION TO THE EXISTING

ACADEMIC BUILDING TO ACCOMMODATE A NEW DENTAL HYGIENE PROGRAM, A

FOOD SERVICE RENOVATION, AND A FACULTY OFFICE SUITE.

THE SCOPE OF THE PROJECT INCLUDES A LEVEL 1 - 1,257 SF FULLY SPRINKLERED

AND DETECTED ADDITION AND A RENOVATION OF 1,953 SF FOR THE DENTAL

HYGIENE PROGRAM. IT INCLUDES A COMPLETE RENOVATION TO THE EXISTING

INTERIOR SPACE OF THE EXISTING APPARATUS BAY, REPLACEMENT OF SYSTEMS

INCLUDING HVAC, INFORMATION & TECHNOLOGY, ELECTRICAL, FIRE SUPPRESSION

AND ALARM AND PLUMBING SYSTEMS ALONG WITH NEW INTERIOR FINISHES. THE

ADDITION WILL BE LOCATED AT THE EAST SIDE OF THE EXISTING APPARATUS BAY

LOCATED ON THE SOUTH SIDE OF THE ACADEMIC BUILDING.

THE LEVEL 1 FOOD SERVICE AREA INCLUDES A MINOR RENOVATION OF THE

EXISTING SPACE.

ON LEVEL 2 THERE IS AN ADDED 1,647 SF LEVEL 2 FLOOR FOR A 1,277 SF FULLY

SPRINKLERED AND DETECTED OFFICE AREA ABOVE THE LEVEL 1 APPARATUS BAY

RENOVATION AREA.

THE EXISTING BUILDING WAS CONSTUCTED AS A FULLY SPRINKLERED AND

DETECTED TYPE II-B, MIXED/NON-SEPERATED

PROJECT SIZE:

EXISTING LEVEL 1: 37,387 GSF

NEW LEVEL: 1,257 GSF

TOTAL: 38,644 GSF

EXISTING LEVEL 2: 29,143 GSF

NEW LEVEL 2: 1,977 GSF

TOTAL: 31,120 GSF

TOTAL: 69,764 GSF

ALLOWABLE AREA PER STORY = 69,000 SQ FT

OCCUPANCY USE GROUP:

304.1 BUSINESS GROUP B (MAIN OCCUPANCY)

ACCESSORY OCCUPANCY:

303.4 ASSEMBLY GROUP A-3 (LESS THAN 10% OF THE MAIN OCCUPANCY)

CONSTRUCTION TYPE:

IIB, FULLY SPRINKLERED

APPLICABLE CODES & STANDARDS:

ACCESSIBILITY ICC A117.1 ACCESSIBLE AND USABLE BUILDINGS AND

FACILITIES, 2017

BUILDING 2021 INTERNATIONAL BUILDING CODE

NFPA 170: STANDARD FOR FIRE SAFETY AND

EMERGENCY SYMBOLS

ELECTRICAL 2020 NATIONAL ELECTRICAL CODE

ENERGY 2021 INTERNATIONAL ENERGY CONSERVATION CODE

FIRE PREVENTION 2021 INTERNATIONAL FIRE CODE

FUEL GAS 2021 COLORADO FUEL & GAS CODE

MECHANICAL 2021 INTERNATIONAL MECHANICAL CODE

PLUMBING 2021 COLORADO PLUMBING CODE

EXISTING 2021 INTERNATIONAL EXISTING BUILDING CODE

OCCUPANCY LOAD: PER IBC TABLE 1004.1.2 & LSC TABLE 7.3.1.2

EXISTING OCCUPANT LOAD (TOTAL): 1,564 OCCUPANTS

EXISTING RENOVATION AREA OCCUPANT LOAD (LEVEL 01): 67 OCCUPANTS

NEW RENOVATION & ADDITION AREA OCCUPANT LOAD (LEVEL 01):

37 OCCUPANTS

30 OCCUPANTS REMOVED

NEW OCCUPANTS ADDED AT LEVEL 02: 12 OCCUPANTS ADDED

TOTAL NEW OCCUPANT LOAD: 1564 - 30 + 12 = 1,546 OCCUPANTS

*SINCE WE DID NOT INCREASE OCCUPANT LOAD, WE HAVE NOT RE-CALCULATED

THE PLUMBING FIXTURES. THE RENOVATION OF THE FIRST FLOOR SCOPE OF

WORK WILL ADD ONE UNISEX RESTROOM TO THE BUILDING.

REQUIRED FIRE RESISTANCE RATINGS:

PER IBC TABLE 601, TABLE 1020.1, 705.8, 713, & LSC 38.3.6

STRUCTURAL FRAME 0 HOURS

INTERIOR BEARING WALLS 0 HOURS

INTERIOR NON-BEARING WALLS & PARTITIONS 0 HOURS

FLOOR CONSTRUCTION 0 HOURS

CORRIDOR WALLS 0 HOURS

SHAFT ENCLOSURES 0 HOURS

OCCUPANCY SEPARATION:

PER IBC TABLE 508.4 & LSC TABLE 6.1.14.4.1

MEANS OF EGRESS:

EXIT ACCESS TRAVEL DISTANCE (IBC TABLE 1017.2 & LSC 18.2.6 & LSC 38.2.6)

MAXIMUM DEAD END CORRIDOR LENGTH (IBC 1020.4 & LSC 18.2.5.2 & LSC 38.2.5.2)

MINIMUM CORRIDOR WIDTH (GUIDELINES 8.2.2.1 & IBC TABLE 1020.1)

MINIMUM DOOR WIDTH (IBC 1010.1.1 & LSC 7.2.1.2.3.2)

COMMON PATH OF TRAVEL (IBC TABLE 1006.2.1 & IBC 407.4 & LSC 18.2.5.3 & LSC

38.2.5.3)

CLIMATE ZONE:

6B

LIFE SAFETY USE CLASSIFICATION

A-3 ASSEMBLY (AUDITORIUMS WITHOUT

PERMANENT SEATING ART GALLERIES

EXHIBITION HALLS MUSEUMS LECTURE

HALLS LIBRARIES ARCADES AND

GYMNASIUMS)

B (NOT PLUMBING)

B ACCESSORY STORAGE AREAS,

MECHANICAL EQUIPMENT ROOM

B BUSINESS (BUILDINGS FOR THE

TRANSACTION OF BUSINESS PROFESSIONAL

SERVICES OTHER SERVICES INVOLVING

MERCHANDISE OFFICE BUILDINGS BANKS

LIGHT INDUSTRIAL AMBULATORY CARE AND

SIMILAR USES)

B EDUCATIONAL OCCUPANCIES ABOVE THE

12TH GRADE

B SHOPS AND OTHER VOCATIONAL ROOM

AREAS

AREA IN HATCH

IS NOT IN SCOPE

FEC

EXISTING A-3 OCCUPANCY

500 SF

10 OCC

RADIOLOGY LAB

50 SF/OCC

No. Date Revision

© Hord Coplan Macht, Inc.

ARCHITECTURE

LANDSCAPE ARCHITECTURE

PLANNING

INTERIOR DESIGN

Drawing

Drawn By

Date (YYYY/MM/DD)

ARCHITECT

Project Number

Project Name

A

B

C

D

E

654321

Checked By

M/E/P ENGINEER

Cator Ruma & Associates Co 896 Tabor St #1 Lakewood, CO 80401

p. 303. 232. 6200

Hord Coplan Macht, Inc.

1800 Wazee Street, Suite 450 Denver, CO 80202

p. 303.607.0977

f. 303.607.0767

A u to d e s k D o c s /2

C

M C

E d w a rd s R a d io lo g y /2

C

M C

E d w a rd s R a d io lo g y

R .r v t

/5

/2

:0 :2

P

M

E D

W A

R D

S R

A D

IO

L O

G Y

L A

B R

E N

O V

A T

IO

N

M ill e r

R a n c h R d E d w a rd s C

O

ISSUE FOR BIDDING AND

CONSTRUCTION

2024/11/05

HCM

C O

L O

R A

D O

M O

U N

T A

IN

C

O L L E

G E

224089

G-003

LIFE SAFETY PLANS - FIRST

FLOOR

EDWARDS RADIOLOGY LAB

RENOVATION

HCM

3/32" = 1'-0" A1

CODE PLAN - FIRST FLOOR

11 OCC.

(EXISTING)

50 OCC.

(EXISTING)

78 OCC.

(EXISTING)

153 OCC.

10 OCC.

(EXISTING)

173 OCC.

3 OCC.

(EXISTING)

173 x .15 = 25.95" REQUIRED

64" PROVIDED

10 x .15 = 1.5" REQUIRED

32" PROVIDED

rdetroit Image rdetroit

AREA IN HATCH

IS NOT IN SCOPE

LIFE SAFETY USE CLASSIFICATION

B (NOT PLUMBING)

B ACCESSORY STORAGE AREAS,

MECHANICAL EQUIPMENT ROOM

B BUSINESS (BUILDINGS FOR THE

TRANSACTION OF BUSINESS PROFESSIONAL

SERVICES OTHER SERVICES INVOLVING

MERCHANDISE OFFICE BUILDINGS BANKS

LIGHT INDUSTRIAL AMBULATORY CARE AND

SIMILAR USES)

B EDUCATIONAL OCCUPANCIES ABOVE THE

12TH GRADE

B SHOPS AND OTHER VOCATIONAL ROOM

AREAS

90' < 100'-0" COMMON PATH TO CHOICE FOR 2 EXITS

(B OCC.)

49'-9" < 50'-0" DEAD-END CORRIDOR

(B OCC.)

1501 SF

11 OCC

OFFICE

150 SF/OCC

+13 OCC

49 SF

1 OCC

IDF

300 SF/OCC

63 SF

1 OCC

STORAGE

300 SF/OCC

13 SF

1 OCC

ROOF ACCESS

300 SF/OCC

OFFICE AREA

CALCULATED AT

1:150

(B-OCCUPANCY)

11 x .15 = 5.5" REQUIRED

32" PROVIDED

NOTE: NO SCOPE OF WORK ON

SECOND FLOOR

No. Date Revision

© Hord Coplan Macht, Inc.

ARCHITECTURE

LANDSCAPE ARCHITECTURE

PLANNING

INTERIOR DESIGN

Drawing

Drawn By

Date (YYYY/MM/DD)

ARCHITECT

Project Number

Project Name

A

B

C

D

E

654321

Checked By

M/E/P ENGINEER

Cator Ruma & Associates Co 896 Tabor St #1 Lakewood, CO 80401

p. 303. 232. 6200

Hord Coplan Macht, Inc.

1800 Wazee Street, Suite 450 Denver, CO 80202

p. 303.607.0977

f. 303.607.0767

A u to d e s k D o c s /2

C

M C

E d w a rd s R a d io lo g y /2

C

M C

E d w a rd s R a d io lo g y

R .r v t

/5

/2

:0 :2

P

M

E D

W A

R D

S R

A D

IO

L O

G Y

L A

B R

E N

O V

A T

IO

N

M ill e r

R a n c h R d E d w a rd s C

O

ISSUE FOR BIDDING AND

CONSTRUCTION

2024/11/05

HCM

C O

L O

R A

D O

M O

U N

T A

IN

C

O L L E

G E

224089

G-004

LIFE SAFETY PLANS

-SECOND FLOOR

EDWARDS RADIOLOGY LAB

RENOVATION

HCM

3/32" = 1'-0"

CODE PLAN - SECOND FLOOR

rdetroit Image rdetroit

DEMOLITION GENERAL

NOTES

1. GENERAL CONTRACTOR TO COORDINATE SCHEDULING ALL WORK

WITH OWNER.

2. WORK LABELED (NIC), OR OTHERWISE NOT NOTED IS NOT IN

CONTRACT FOR ANY ARCHITECTURAL IMPROVEMENTS.

3. THE GENERAL CONTRACTOR & THEIR SUBCONTRACTORS SHALL

VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS WITH CONDITIONS

SHOWN IN THE CONTRACT DOCUMENTS AND SHALL REPORT ANY

DEVIATIONS, DISCREPANCIES AND/OR CONFLICTS TO ARCHITECT.

4. THE GENERAL CONTRACTOR & SUBCONTRACTOR SHALL TAKE

EXTREME CARE DURING DEMOLITION NOT TO DAMAGE OR DISTURB

ANY EXISTING CONDITIONS THAT ARE TO REMAIN. GENERAL

CONTRACTOR OR SUBCONTRACTOR SHALL REPAIR ANY DAMAGE OR

DISTURBANCE TO EXISTING CONDITIONS AT NO COST TO THE OWNER.

5. PROVIDE PROTECTION FOR FLOORS, WALLS, & CEILING AT ALL

EXISTING CONDITIONS TO REMAIN, INCLUDING TRAFFIC AREA FOR

DEMOLITION REMOVAL IN COMMON BUILDING AREAS & DAMAGED

FLOORS WILL BE REPLACED @ NO COST TO OWNER.

6. REMOVE ALL DOORS AND OTHER ITEMS) SHOWN DASHED.

7. REFER TO SPECIFICATIONS REGARDING; EXISTING CONDITIONS,

CUTTING AND PATCHING AND SELECTIVE DEMOLITION REQUIREMENTS

THAT APPLY TO ALL WORK KEY NOTES DESCRIBED ON THIS SHEET.

8. REFER TO ELECTRICAL, MECHANICAL, ETC.) DEMOLITION DRAWINGS

FOR ADDITIONAL ITEMS.

9. COORDINATE W/ BUILDING OWNER DURING DEMOLITION TO

DETERMINE WHETHER EXISTING FIRE & SMOKE DETECTION SYSTEMS

ARE TO BE BAGGED, PROTECTED & REMAIN IN OPERATION OR TO BE

TAKEN OFF LINE.

10. AREAS OF DEMOLITION SHALL BE FREE OF FURNITURE AND MOBILE

EQUIPMENT AND ACCESSORIES PRIOR TO START OF WORK.

11. REMOVE STAPLES, NAILS AND SCREWS FROM WALLS TO REMAIN,

TYPICAL THROUGHOUT.

12. REMOVE AND SALVAGE ALL SIGNAGE, CLOCKS, EMERGENCY KITS,

PENCIL SHARPENERS AND PHONES FROM WALLS, INSIDE

CLASSROOM. PATCH AND REPAIR WALLS WHERE DAMAGED BY

REMOVAL. SALVAGE AND RETURN TO OWNER.

13. REMOVE AND REPLACE ALL EXISTING SWITCH PLATES AND OUTLET

COVERS FROM EXISTING WALLS AND REPLACE WITH NEW PLATES PER

SPEC.

14. REMOVE ALL FLOORING (INCLUDING ADHESIVES, SETTING MATERIALS,

TRANSITION MATERIALS, ETC.) AND (RUBBER) WALL BASE. PROTECT

WALLS FROM DAMAGE.

OFFICE

131 C

OFFICE

131 B

OFFICE

131 A

CLASSROOM

HALLWAY

CLASSROOM

HALLWAY

PUBLIC

LOUNGE

AREA

507 SF

OFFICE

131 C

OFFICE

131 B

OFFICE

131 A

CLASSROOM

DEMOLITION RCP

GENERAL NOTES

1. REMOVE AND SALVAGE ALL LIGHT FIXTURES, GRILLS AND RETURNS

AND CLEAN AND REPAIR TO "LIKE NEW" CONDITIONS AND TURNOVER

TO OWNER OR REINSTALL AS INDICATED.

2. REFER TO ELECTRICAL DRAWINGS FOR ADDITIONAL INFORMATION.

3. REMOVE AND SALVAGE ALL CEILING MOUNTED EQUIPMENT

PROJECTORS, PULL DOWN SCREENS, SPEAKERS, ETC. TURN OVER TO

OWNER.

No. Date Revision

© Hord Coplan Macht, Inc.

ARCHITECTURE

LANDSCAPE ARCHITECTURE

PLANNING

INTERIOR DESIGN

Drawing

Drawn By

Date (YYYY/MM/DD)

ARCHITECT

Project Number

Project Name

A

B

C

D

E

654321

Checked By

M/E/P ENGINEER

Cator Ruma & Associates Co 896 Tabor St #1 Lakewood, CO 80401

p. 303. 232. 6200

Hord Coplan Macht, Inc.

1800 Wazee Street, Suite 450 Denver, CO 80202

p. 303.607.0977

f. 303.607.0767

A u to d e s k D o c s /2

C

M C

E d w a rd s R a d io lo g y /2

C

M C

E d w a rd s R a d io lo g y

R .r v t

/5

/2

:0 :1

P

M

E D

W A

R D

S R

A D

IO

L O

G Y

L A

B R

E N

O V

A T

IO

N

M ill e r

R a n c h R d E d w a rd s C

O

ISSUE FOR BIDDING AND

CONSTRUCTION

2024/11/05

Checker

C O

L O

R A

D O

M O

U N

T A

IN

C

O L L E

G E

224089

AD-111

DEMOLITION FOOR PLAN

AND REFLECTED CEILING

PLAN

EDWARDS RADIOLOGY LAB

RENOVATION

Author

1/4" = 1'-0" A1

FIRST FLOOR DEMO PLAN

SHEET NOTES - DEMO PLAN

NOTE # NOTE

1 REMOVE MARKERBOARDS, SCREEN AND SPEAKERS. SALVAGE AND

RETURN TO OWNER

2 RELOCATE T STAT, ALERT BUTTON AND LIGHT SWITCHES TO MAKE

ROOM FOR ENLARGED DOOR. RE: ELECTRICAL

3 REMOVE PORTION OF THE WALL FOR NEW WIDER DOOR

4 REMOVE (E) ROOM PANEL SIGN AND TURN OVER TO OWNER.

5 REMOVE EXISTING HM FRAME, WOOD DOOR AND HARDWARE.

SALVAGE HARDWARE AND ALL EXCEPT HINGES REUSE ON

REPLACEMENT DOOR.

6 REMOVE EXISTING CARPET FLOORING AND RUBBER BASE.

7 REMOVE EXISTING PENCIL SHARPENER AND RETURN TO OWNER

1/4" = 1'-0" A4

FIRST FLOOR DEMO REFLECTED CEILING PLAN

SHEET NOTES - DEMO RCP

NOTE # NOTE

1 REMOVE AND SALVAGE(2) DIRECT/INDIRECT PENDANT LIGHT

FIXTURES AND RETURN TO OWNER

2 EXISTING ACOUSTIC CEILING TILE CEILING TO REMAIN. REPLACE

DAMAGED TILES AS NEEDED DURING CONSTRUCTION.

A- EXISTING DOOR FROM HALLWAY B- EXISTING CLASSROOM

rdetroit Image rdetroit

A-111

A1

No. Date Revision

© Hord Coplan Macht, Inc.

ARCHITECTURE

LANDSCAPE ARCHITECTURE

PLANNING

INTERIOR DESIGN

Drawing

Drawn By

Date (YYYY/MM/DD)

ARCHITECT

Project Number

Project Name

A

B

C

D

E

654321

Checked By

M/E/P ENGINEER

Cator Ruma & Associates Co 896 Tabor St #1 Lakewood, CO 80401

p. 303. 232. 6200

Hord Coplan Macht, Inc.

1800 Wazee Street, Suite 450 Denver, CO 80202

p. 303.607.0977

f. 303.607.0767

A u to d e s k D o c s /2

C

M C

E d w a rd s R a d io lo g y /2

C

M C

E d w a rd s R a d io lo g y

R .r v t

/5

/2

:0 :1

P

M

E D

W A

R D

S R

A D

IO

L O

G Y

L A

B R

E N

O V

A T

IO

N

M ill e r

R a n c h R d E d w a rd s C

O

ISSUE FOR BIDDING AND

CONSTRUCTION

2024/11/05

Checker

C O

L O

R A

D O

M O

U N

T A

IN

C

O L L E

G E

224089

A-110

OVERALL FIRST FLOOR PLAN

EDWARDS RADIOLOGY LAB

RENOVATION

Author

1/16" = 1'-0"

A1 OVERALL FIRST FLOOR PLAN

rdetroit Image rdetroit

1. DIMENSIONS INDICATED ARE TO FACE OF FINISH MATERIAL OF

PARTITION OR WALL AND GRID LINES, UON

2. VERIFY & COORDINATE ALL REQUIREMENTS FOR OWNER FURNISHED

ITEMS PRIOR TO PERFORMANCE OF WORK THAT MAY INTERFACE WITH

SUCH ITEMS.

3. PROVIDE PAINTED ACCESS PANELS IN WALLS & CEILINGS AT

CONCEALED ITEMS, SUCH AS VALVES, CONTROLS, SWITCHES OR ANY

OTHER ITEMS THAT REQUIRES ACCESS. GC TO DETERMINE ACCESS

PANEL LOCATION W/ ARCHITECT PRIOR TO INSTALLATION.

FLOOR PLAN

GENERAL NOTES

OFFICE

131 A

OFFICE

131 B

OFFICE

131 C

X-RAY ROOM

133B

WAITING AREA

133A

X-RAY TABLE

BY OWNER

2' - 0"

HALLWAY

CLASSROOM

HALLWAY

PUBLIC

LOUNGE

AREA

7' - 1"

5' - 0"

9' - 6"

3' - 0"

/4

7' - 7"

EQ

EQ

6' - 5 3/4"

CL TABLE / WALL STAND

4' - 4"

1' - 0" 1' - 0"

0' - 3"

135.00°

.0

MIN 1/64" LEAD LINED

DRYWALL INSTEAD OF

EXTRA LAYER OF DRYWALL

109 SF

OFFICE

131 A

111 SF

OFFICE

131 B

112 SF

OFFICE

131 C

231 SF

X-RAY ROOM

133B

RCP GENERAL NOTES

1. REFER TO MEP AND IT DRAWINGS FOR ADDITIONAL INFORMATION.

2. PROTECT EXISTING ACOUSTIC CEILING TILE SYSTEM DURING

CONSTRUCTION. REPLACE CEILING TILES DAMAGED DURING

RENOVATION.

TYPE C

PAPER INSERT (1.25" X 7.0")

BY OWNER

RAISED HELVETICA

MEDIUM TEXT, TYP.

BRAILLE, TYP.

ACRYLIC WINDOW OPEN AT

BOTH ENDS FOR CHANGABLE

TEXT (BY OWNER)

RADIOLOGY

LAB

7"

/2

/2

W1

5' - 0"

0' - 2"

6" 6"

N

4' - 0"

2"

4' - 0"

2"

A

WALL LEGEND

ADD (1) LAYER OF 5/8" GWB OVER EXISTING GWB FROM FLOOR TO UNDERSIDE OF (E) CEILING.

EXTEND ALL POWER/DATA RECEPTACLES TO NEW FACE OF WALL AS NEEDED FOR THICKER WALL

FINISH. PROVIDE 1/32" THICK LEAD SHEET BEHIND J-BOXES AT ALL WALL PENETRATIONS

ADD 1/32" LEAD LINED GWB OVER EXISTING GWB. FROM FLOOR TO UNDERSIDE OF (E)

CEILING EXTEND MIN 1'-0" PAST EACH SIDE OF X-RAY WALL STAND EQUIPMENT. PROVIDE

1/32" THICK LEAD SHEET BEHIND J-BOXES AT ALL WALL PENETRATIONS

ADD 1/64" LEAD LINED GWB OVER EXISTING GWB FROM FLOOR TO UNDERSIDE OF (E)

CEILING. PROVIDE 1/64" THICK LEAD SHEET BEHIND ANY J-BOXES AT ALL WALL

PENETRATIONS.

No. Date Revision

© Hord Coplan Macht, Inc.

ARCHITECTURE

LANDSCAPE ARCHITECTURE

PLANNING

INTERIOR DESIGN

Drawing

Drawn By

Date (YYYY/MM/DD)

ARCHITECT

Project Number

Project Name

A

B

C

D

E

654321

Checked By

M/E/P ENGINEER

Cator Ruma & Associates Co 896 Tabor St #1 Lakewood, CO 80401

p. 303. 232. 6200

Hord Coplan Macht, Inc.

1800 Wazee Street, Suite 450 Denver, CO 80202

p. 303.607.0977

f. 303.607.0767

A u to d e s k D o c s /2

C

M C

E d w a rd s R a d io lo g y /2

C

M C

E d w a rd s R a d io lo g y

R .r v t

/5

/2

:0 :2

P

M

E D

W A

R D

S R

A D

IO

L O

G Y

L A

B R

E N

O V

A T

IO

N

M ill e r

R a n c h R d E d w a rd s C

O

ISSUE FOR BIDDING AND

CONSTRUCTION

2024/11/05

HCM

C O

L O

R A

D O

M O

U N

T A

IN

C

O L L E

G E

224089

A-111

FIRST FLOOR PLAN

EDWARDS RADIOLOGY LAB

RENOVATION

HCM

1/4" = 1'-0" A1

FIRST FLOOR PLAN

SHEET NOTES - FLOOR PLANS

NOTE # NOTE

1 NEW WOOD DOOR TO MATCH EXISTING DOORS ON SITE AND NEW HM FRAME. PAINT HM

FRAME TO MATCH EXISTING FRAMES ON SITE. PROVIDE HARDWARE SET AS INDICATED

IN LEGEND FOR NEW DOOR 133A, WHICH IS TO INCLUDE SECURITY CARD ACCESS.

PROVIDE ONE 1-POLE, SINGLE THROW, MOMENTARY EXPOSURE INTERLOCK SWITCH IN

DOOR FRAME TIED TO X-RAY EQUIPMENT CONTROLS AS INDICATED IN MEDICAL

EQUIPMENT DRAWINGS ON ME-100.

2 NEW MIN 6 mm PLATE GLASS WINDOW IN HM FRAME. PAINT FRAME TO MATCH DOOR

FRAME. RE: W1 WINDOW ELEVATION

3 X-RAY WALL STAND EQUIPMENT BY OWNER. PROVIDE WALL BACKING - 2 X 8 X 24

CENTERED AT 81.5" A.F.F. ANCHOR TO WITHSTAND PULL OF 150 LBS (FLUSH MOUNT)

4 PROVIDE NEW ROOM PANEL SIGN TO MATCH (E) PANEL SIGNS ON SITE. LOCATE

ADJACENT TO NEW DOOR FRAME. RE: SIGNAGE SCHEDULE AND ELEVATION FOR

CONTENT

5 MEDICAL EQUIPMENT GENERATOR BY OWNER

6 PROVIDE "X-RAY IN USE" SIGN MOUNTED ABOVE DOOR. RE: ELECTRICAL FOR POWER

REQUIREMENTS

7 WARDROBE FURNITURE BY OWNER

8 CUBBIES FURNITURE BY OWNER

9 PROVIDE ROLLED SHEET VINYL FLOORING: MANNINGTON COMMERCIAL, BOARDWALK,

COLOR: COCONUT, WITH MANUFACTURER'S RECOMENDED WELD ROD COLOR. PROVIDE

RUBBER WALL BASE: TARKETT, 4" COVE ROLLED GOODS, COLRO: FAWN

10 PAINT ALL WALLS - SHERWIN WILLIAMS EGGSHELL FINISH, COLOR; SW6133 MUSLIN

11 X-RAY EQUIPMENT AND TABLE BY OWNER

12 5/8" GWB EACH SIDE OF 3 5/8" METAL STUD TO UNDERSIDE OF EXISTING CEILING. RE:

SHEET A-410 FOR DETAILS. PROVIDE 1/32" THICK LEAD SHEET BEHIND EQUIPMENT AT

ALL WALL PENETRATIONS

13 SOLID SURFACE COUNTERTOP WITH 1 1/2" THICK BULLNOSE NOSING, 4" APRON, AND 4"

BACKSPLASH

1/4" = 1'-0" B1

FIRST FLOOR REFLECTED CEILING PLAN

SHEET NOTES - RCP

NOTE # NOTE

1 REPLACE CEILING TILES AS NEEDED WHERE DAMAGED DURING

CONSTRUCTION. ASSUME REPLACEMENT OF 50% OF TILES. MATCH

EXISTING TILE ON SITE.

SIGNAGE TYPES

SIGNAGE SCHEDULE

Signage Door

Mark Signage Type Signage Number Signage Text Signage Placement Comments

133 C 133 RADIOLOGY LAB CORRIDOR

HOLLOW METAL 6MM PLATE GLASS WINDOWDOOR TYPES FRAME TYPES

EQUIPMENT PROVIDED BY OWNER'S MEDICAL EQUIPMENT SUPPLIER (RE: ME-100)

3 BEST HINGE - FBB179 4.5" X 4.5" NRP 26D

1 BEST STOREROOM LOCKSET - 9K3-7D14D L/C S3B 626

1 BEST PERMANENT CORE BY OWNER 626

1 HES ELECTRIC STRIKE - 8300C SERIES X 2005M3 630

1 LCN CLOSER W/ HOLD-OPEN ARM - 4040XP HWPA AL

1 TRIMCO KICK PLATE - K0050 10" X 2" LDW B4E CSK 630

1 TRIMCO WALL BUMPER - 1270CVSV 626

1 NATIONAL GUARD PRODUCTS GASKETING - 5050 @ HEAD & JAMBS

1 JUNCTION BOX BY ELECTRICAL

1 CARD READER BY OWNERS SECURITY INTEGRATOR

1 DOOR CONTACT BY OWNERS SECURITY INTEGRATOR

1 WIRING & RISER DIAGRAM COORDINATE W/ RELATED TRADES

HARDWARE SCHEDULE FOR OPENING 133A

rdetroit Image rdetroit

A L

IG

N

E L

E M

E N

T S

W

H E

N A

D J A

C E

N

O D

O O

R

F

IR

E A

L A

R M

H O

R N

R O

B E

C A

R D

E A

D E

R

L

IG

W

IT

C H

E S

T H

E R

M O

S T

A T

T Y

P

V

P

W

E R

/D A

A

F

C

R R

ID

L

C A

T

IO

N S

T Y

P

P

W

E R

/D A

F

A T

IN

G

L

C A

T

IO

N S

R

E E

L E

V

T Y

P

T V

P O

W E

R /D

A T

A H

T

F

E R

H E

A D

L O

C A

T

IO

N S

T Y

P

G F

I H

T

F O

R V

E N

D

M

C H

IN

E

T Y

P

P O

W

F

N

D

C H

IN

E

MISCELLANEOUS ITEMS NEAR

DOORS

OFFICE ELECTRICAL

MOUNTING HEIGHTS

110V DUPLEX OR

STD. TELE/DATA

GANG SWITCHES: LIGHTS,

DIMMERS, SHADES, SCREENS,

PROJECTORS, ETC.

COORDINATE AROUND

LOCATIONS INTENDED FOR ART,

PROJ. SCREENS, MARKER

AND/OR TACKABLE MATERIALS

TYPICAL HEIGHT

ABOVE

COUNTERS

AREA OF

REFUGE

M

IN

M A

X

18"x18" CLEAR FLOOR SPACE, O.C.

OF SIGNAGE, LATCH SIDE OF DOOR.

DOOR STOP

9" 9"

N O

M

/4

M32-

PARTITION HEAD

---A

PLAN DETAIL @ PARTITION

INTERSECTION

ASSEMBLY

RATED WALL

PLAN DETAIL - NON-RATED

CONTROL JOINT

1/2"

PARTITION TYPES NOTES

GYP BD- BOTH

SIDES

METAL STUD

BASE- RE: FINISH

PLAN

RUNNER CHANNEL

SEALANT- BOTH

SIDES

WITH 3-5/8" METAL STUD

(NOMINAL WIDTH 3)

PARTITION WIDTH = 4-7/8"

STC: 45

SEE GENERAL PARTITION TYPE FOR REQUIRED STUD SIZE AND

LAYERS OF GYP. BD. (4 LAYERS SHOWN)

RE: PLANS FOR

SCHEDULED PARTITION

TYPES

GYP. BD. ACCESSORY -

CONTROL JOINT -

BOTH SIDES

SEALANT - BOTH SIDES

1. PARTITION TYPES ARE INDICATED ON THE FLOOR PLANS.

2. PROVIDE FIRE-RETARDANT TREATED WOOD BLOCKINGOR SHEET METAL

STRAPPING FOR PARTITION MOUNTED EQUIPMENT AND CASEWORK.

4. PROVIDE GYP. BD. CONTROL JOINTS ANYWHERE THERE IS A

CONTINUOUS RUN OF GYP. BD. THAT IS GREATER THAN 30'-0" IN LENGTH.

CONFIRM THE LOCATION OF ADDITIONAL CONTROL JOINTS WITH THE

ARCHITECT PRIOR TO INSTALLATION.

FLOOR LINE

H E

A D

C O

N D

IT

IO

N

RE: PLANS FOR

SCHEDULED PARTITION

TYPES

PARTITION TYPE 2

EXISTING CEILING

5/8" BOTH SIDES

DEEP LEG TOP

TRACK

ANCHOR TOP OF PARTITION TO

METAL DECK FLOOR STRUCTURE

ABOVE WITH LIGHT GAUGE METAL

STUDS

No. Date Revision

© Hord Coplan Macht, Inc.

ARCHITECTURE

LANDSCAPE ARCHITECTURE

PLANNING

INTERIOR DESIGN

Drawing

Drawn By

Date (YYYY/MM/DD)

ARCHITECT

Project Number

Project Name

A

B

C

D

E

654321

Checked By

M/E/P ENGINEER

Cator Ruma & Associates Co 896 Tabor St #1 Lakewood, CO 80401

p. 303. 232. 6200

Hord Coplan Macht, Inc.

1800 Wazee Street, Suite 450 Denver, CO 80202

p. 303.607.0977

f. 303.607.0767

A u to d e s k D o c s /2

C

M C

E d w a rd s R a d io lo g y /2

C

M C

E d w a rd s R a d io lo g y

R .r v t

/5

/2

:0 :1

P

M

E D

W A

R D

S R

A D

IO

L O

G Y

L A

B R

E N

O V

A T

IO

N

M ill e r

R a n c h R d E d w a rd s C

O

ISSUE FOR BIDDING AND

CONSTRUCTION

2024/11/05

Checker

C O

L O

R A

D O

M O

U N

T A

IN

C

O L L E

G E

224089

A-410

TYPICAL MOUNTING

HEIGHTS, ASSEMBLY AND

PARTITION TYPES

EDWARDS RADIOLOGY LAB

RENOVATION

Author

TYP. MOUNTING HEIGHTS

rdetroit Image rdetroit

DOUBLE/SINGLE LINE DUCT LEGEND

45° TEE (ROUND) FLEX DUCT 90° RADIUS ELBOW

RIGID FLEX

45° TEE (RECTANGULAR) 90° TEE (ROUND) MANUAL VOLUME DAMPER 90° ELBOW

DUCT SPLIT REDUCER 45° ELBOWGRD RUNOUT

90° TEE (RECTANGULAR)

SEE DETAIL

CONICAL

TEE

TAKEOFF

WITH VOLUME

DAMPER

SINGLE LINEDOUBLE LINEDOUBLE LINESINGLE LINE SINGLE LINE

FLEXRIGID

SINGLE LINE DOUBLE LINE DOUBLE LINE

R N

D

R E

C

(Not all symbols listed below are used on these drawings)

HVAC LEGEND

SYMBOL DESCRIPTION ABBR. DESCRIPTION

LOW PRESSURE CONDENSATE RETURN PIPING

HEATING WATER SUPPLY PIPING

HEATING WATER RETURN PIPING

CHILLED WATER SUPPLY PIPING

CHILLED WATER RETURN PIPING

SUPPLY DUCT UP / DOWN

RETURN DUCT UP / DOWN

FLEXIBLE DUCT CONNECTION

BACKDRAFT DAMPER

TEMP. CONTROL DAMPER-OPPOSED BLADE

MANUAL VOLUME DAMPER

DUCT MOTORIZED DAMPER

CONICAL FITTING WITH MVD

CONDENSER WATER SUPPLY PIPING

LOW PRESSURE STEAM SUPPLY PIPING (0 - 15#)

ROUND DUCT UP / ROUND DUCT DOWN

FLAT OVAL DUCTWORK

ABBR. SYMBOL

COOLING COIL DRAIN PAN PIPING

TEMP. CONTROL DAMPER- PARALLEL BLADE

LPS

LPC

MPS

MVD

MPC

BBD

BF

RL

RS

RHG

TT

MEDIUM PRESSURE STEAM SUPPLY PIPING (16# - 60#)

MEDIUM PRESSURE CONDENSATE RETURN PIPING

HIGH PRESSURE STEAM SUPPLY PIPING (61# - 125#)

HIGH PRESSURE CONDENSATE RETURN PIPING

PUMPED CONDENSATE PIPING

BOILER BLOWDOWN PIPING

REFRIGERANT SUCTION PIPING

BOILER FEED WATER PIPING

FLOAT AND THERMOSTATIC STEAM TRAP

REFRIGERANT LIQUID PIPING

REFRIGERANT HOT GAS PIPING

TCD

FD

FSD

SD

DAD

DUCT FIRE DAMPER

COMBINATION DUCT FIRE/SMOKE DAMPER

DUCT SMOKE DAMPER

DUCT SMOKE DETECTOR

DUCT ACCESS DOOR

ELECTRIC-PNEUMATIC CONTROL VALVE

TURNING VANES IN DUCT ELBOW

WALL SWITCH / EMERGENCY SWITCH

PNEUMATIC-ELECTRIC CONTROL SWITCH

HUMIDISTAT

DUCT RISE

UNIT MOUNTED THERMOSTAT

UNDERCUT DOOR

THERMOSTATIC STEAM TRAP

DUCT DROP

HWS

HWR

CHWS

CHWR

D

CWS

CWR

HPS

HPC

PC

F&T

IBT

TCV

FS

EJ

BJ

RSV

DPS

(2 OR 3-WAY) TEMPERATURE CONTROL VALVE

INVERTED BUCKET STEAM TRAP

VENTURI METER

CALIBRATED BALANCING VALVE

REFRIGERANT SERVICE VALVE

DIFFERENTIAL PRESSURE SWITCH

FLOW SWITCH

EXPANSION JOINT

CONDENSER WATER RETURN PIPING

BALL JOINT EXPANSION COMPENSATOR

ACOUSTICALLY LINED DUCTWORK

TEMPERATURE CONTROL OUTSIDE AIR DAMPER

TEMPERATURE CONTROL RETURN AIR DAMPER

TEMPERATURE CONTROL EXHAUST AIR DAMPER

STATIC PRESSURE IN INCHES WATER COLUMN

SUPPLY AIR DEVICE

RETURN AIR DEVICE

M

F

S

T

H

U

RISE

SD

RG

SP IN WC

TCEAD

TCRAD

TCOAD

A.L.

TCD

BDD

EP

PE

(Not all symbols listed below are used on these drawings)

EXHAUST DUCT UP / DOWN

WALL MOUNTED CARBON DIOXIDE SENSORCO2

EXHAUST AIR DEVICEEG

DP

T IBT

F&T

TT

RETURN AIR DEVICE WITH SOUND BOOTRG

GENERAL LEGEND

SYMBOL DESCRIPTION ABBR. DESCRIPTION

NEW

SECTION DESIGNATION

SECTION CUT ON THIS SHEET

VIEW REFERENCE DESIGNATION

VIEW REFERENCE ON THIS SHEET

EQUIPMENT UNIT IDENTIFICATION

CAP END OF PIPE

PITCH DOWN IN DIRECTION OF ARROW

UNION OR FLANGE

CONCENTRIC PIPE REDUCER

ECCENTRIC PIPE REDUCER

PRESSURE AND/OR TEMPERATURE RELIEF VALVE

ISOLATION VALVE (RE: SPEC FOR TYPE)

VERTICAL PIPE VALVE

DIFFUSER IDENTIFICATION

EXISTING

PIPE ANCHOR

PIPE ALIGNMENT GUIDE

ABBR. SYMBOL

EQUIPMENT UNIT NUMBER (UNIT SERVED - FLOOR -

SEQUENCE #)

PRESSURE REDUCING VALVE

(E)

(N)

(R)

PTRV

(F)

DIA

WAD

NIC

AFF

GC

MC

EC

RELOCATED

FUTURE

POINT OF CONNECTION, NEW TO EXISTING

DIRECTION OF FLOW IN PIPE

DUCTWORK, PIPING AND EQUIPMENT TO BE REMOVED

DIAMETER

ABOVE FINISHED FLOOR

WALL ACCESS DOOR

ELECTRICAL CONTRACTOR

NOT IN CONTRACT

GENERAL CONTRACTOR

PRV

CV

P/T

STRAINER W/ BLOWDOWN

CHECK VALVE

SOLENOID / MOTORIZED VALVE

PRESSURE / TEMPERATURE TAP

SOLENOID VALVE

BRAIDED FLEXIBLE PIPE CONNECTOR

HOSE END DRAIN VALVE

STRAINER

CEILING ACCESS PANEL

PRESSURE GAUGE

PUMP

THERMOMETER

SIGHT GLASS

C.A.P.

TB

MECHANICAL CONTRACTOR

1-2-3

X

THRUST BLOCK

P/T

SLOPE

(Not all symbols listed below are used on these drawings)

A

FIRE PROTECTION LEGEND

SYMBOL DESCRIPTION ABBR. DESCRIPTION

FIRE SERVICE PIPING

O.S.&Y. GATE VALVE W/ TAMPER SWITCH

FLOW SWITCH

POST INDICATOR VALVE

FIRE VALVE CABINET

FIRE DEPARTMENT CONNECTION

SIDEWALL SPRINKLER HEAD

ABBR. SYMBOL

PIV

FS

FDC

F

FVC

(Not all symbols listed below are used on these drawings)

DIFFUSER NECK DIAMETER

DIFFUSER CFM

LINEAR DIFFUSER IDENTIFICATION

8ø/24"L

E

LINEAR DIFFUSER NECK DIAMETER

LINEAR DIFFUSER LENGTH

LINEAR DIFFUSER CFM

FINNED TUBE RADIATOR ACTIVE ELEMENT LENGTH

EQUIPMENT UNIT IDENTIFICATION

EQUIPMENT UNIT NUMBER

RADIATOR ENCLOSURE LENGTH (OR W-W=WALL-TO-WALL)

FTR2'-6"

3'-6"

DOUBLE-BOWL FLEXIBLE PIPE CONNECTOR

MANUAL AIR VENT

AUTOMATIC AIR VENT

20 8

GLYCOL HEATING WATER SUPPLY PIPING

GLYCOL HEATING WATER RETURN PIPING

PROCESS CHILLED WATER SUPPLY PIPING

PROCESS CHILLED WATER RETURN PIPING

GHWS

GHWR

PCWS

PCWR

BV

O WALL MOUNTED OXYGEN SENSOR

WALL MOUNTED THERMOSTATT

ES

DROP

O.S.&Y.

AUTO FLOW VALVEAFV

MD

KITCHEN/OWNER/MEDICAL EQUIPMENT REFERENCE1

TYPICAL ROOM REFERENCE (TOP = RM #, BOTTOM = FLR)

X X

X KEY NOTE REFERENCE

F

MAV

AAV

UNO UNLESS NOTED OTHERWISE

Ø

X

X-X

LPS

LPC

MPS

MPC

BBD

BF

RL

RS

RHG

HWS

HWR

CHWS

CHWR

D

CWS

CWR

HPS

HPC

PC

GHWS

GHWR

PCWS

PCWR

48F12

SPIN-IN FITTING WITH MVD

RELOCATED SPRINKLER HEAD

EXISTING SPRINKLER HEAD

NEW SPRINKLER HEAD

DRY SPRINKLER HEAD (SHAFT LENGTH)

AUTOMATIC FIRE SPRINKLER

FIRE HOSE CABINETFHC

D24

A/S

C

NC NORMALLY CLOSED

COMMON

NO NORMALLY OPEN

LOUVER IN DOORL

TEMPERATURE SENSORTS

HIGH TEMPERATURE HEATING WATER SUPPLY PIPING

HIGH TEMPERATURE HEATING WATER RETURN PIPING

HTWS

HTWR

HTWS

HTWR

X

X-X

POINT OF DISCONNECTION, DEMO

PRESSURE SENSOR / PRESSURE MONITORP PM

END OF MAIN DRIPEOMD

SHORT CIRCUIT CURRENT RATINGSCCR

SA

RA

EA

SUPPLY AIR

OA

RETURN AIR

EXHAUST AIR

OUTSIDE AIR

No. Date Revision

© Hord Coplan Macht, Inc.

ARCHITECTURE

LANDSCAPE ARCHITECTURE

PLANNING

INTERIOR DESIGN

Drawing

Drawn By

Date (YYYY/MM/DD)

ARCHITECT

Project Number

Project Name

A

B

C

D

E

654321

Checked By

M/E/P ENGINEER

Cator Ruma & Associates Co 896 Tabor St #1 Lakewood, CO 80401

p. 303. 232. 6200

Hord Coplan Macht, Inc.

1800 Wazee Street, Suite 450 Denver, CO 80202

p. 303.607.0977

f. 303.607.0767

/5

/2

:1

:1

A

M

E D

W A

R D

S R

A D

IO

L

O G

Y L

A B

R E

N O

V A

T

IO

N M ill e r

R a n c h R d E d w a rd s C

O

P

C M

C \V a il

V a lle y a t E d w a rd s \2

-1

R a d io lo g y

R e n o va ti o n \C a d

CONSTRUCTION

DOCUMENTS

2024/11/05

RWL

C O

L O

R A

D O

M O

U N

T A

IN

C

O L L E

G E

224089

M-001

MECHANICAL AND PLUMBING

LEGENDS & NOTES

EDWARDS RADIOLOGY LAB

RENOVATION

LKL

GENERAL NOTES:

1. WORK INCLUDED IN THE CONTRACT IS DENOTED IN BOLD. EXISTING

CONDITIONS TO REMAIN ARE DENOTED LIGHTLY.

2. A DETAILED METHOD OF PROCEDURE IS REQUIRED WHEN A CONSTRUCTION

ACTIVITY AFFECTS THE SAFETY OF THE OCCUPANTS, OWNER'S EQUIPMENT OR

VALUABLE CONTENTS OR ANY SYSTEM WHICH SUPPORTS THESE SYSTEMS;

OR ESSENTIALLY AFFECTS THE BUILDING MANAGEMENT, OPERATIONS OR

SECURITY.

3. CONTRACTOR IS RESPONSIBLE FOR FIELD VERIFICATION OF ALL EXISTING

CONDITIONS PRIOR TO COMMENCEMENT OF ANY WORK AND SHALL NOTIFY

THE ENGINEER/ARCHITECT OF ANY DISCREPANCIES FOR RESOLUTION.

4. COORDINATE WORK WITH ALL TRADES.

5. CONTRACTOR IS RESPONSIBLE FOR SECURING AND WEATHERPROOFING ANY

ROOF OPENING NOT COMPLETED DURING WORKING HOURS.

6. COORDINATE ALL DUCTWORK AND PIPING WITH EQUIPMENT, STRUCTURE,

ETC.

7. CONTRACTOR SHALL BE RESPONSIBLE FOR DEACTIVATION OF ROOF-

MOUNTED EQUIPMENT AND ASSOCIATED INDOOR EQUIPMENT. ONLY ONE UNIT

SHALL BE TAKEN OUT OF SERVICE AT ANY TIME, WITH REMAINDER OF UNITS

LEFT OPERATIONAL.

8. CONTRACTOR SHALL NOT SHUT DOWN / TAKE OUT OF SERVICE ANY SYSTEMS

WITHOUT FIRST COORDINATING WITH OWNER AND PREPARING M.O.P.

DEMOLITION GENERAL NOTES:

1. EXISTING ITEMS TO REMAIN ARE DENOTED LIGHTLY UNLESS OTHERWISE

NOTED. ALL ITEMS SHOWN DASHED & BOLD SHALL BE REMOVED UNLESS

OTHERWISE NOTED.

2. CONTRACTOR SHALL NOT SHUT-OFF OR PUT-OUT OF SERVICE ANY SYSTEMS

OR SERVICE WITHOUT FIRST COORDINATING WITH THE OWNER.

3. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO VISIT THE SITE AND

UNDERSTAND THE EXTENT OF THE REMODEL WORK REQUIRED PRIOR TO BID.

NO EXTRAS WILL BE ALLOWED FOR WORK REQUIRED TO ACHIEVE THE END

RESULT AS INDICATED BY THE CONTRACT DOCUMENT.

4. CONTRACTOR SHALL DETERMINE AND COORDINATE THE EXACT EXTENT OF

DEMOLITION TO FACILITATE ALL WORK INDICATED BY THE CONTRACT

DOCUMENT.

5. PRIOR TO COMMENCEMENT OF ANY DEMOLITION WORK, VERIFY EXISTING

CONDITIONS AND NOTIFY ENGINEER OF ANY DISCREPANCIES FOR

RESOLUTION.

6. ALL ITEMS IDENTIFIED TO BE REMOVED SHALL BE REMOVED IN THEIR ENTIRETY

UNLESS OTHERWISE NOTED. REMOVED ITEMS SHALL BE TURNED OVER TO THE

OWNER UNLESS OTHERWISE NOTED AND STORED IN THE AREA DESIGNATED

BY THE OWNER. REMOVE FROM SITE AND LEGALLY DISPOSE OF ALL ITEMS THE

OWNER CHOOSES NOT TO ACCEPT.

7. WHERE EXISTING PIPING, T.C. TUBING/WIRING ETC. ARE TO BE REMOVED FROM

WALLS WHICH ARE REMAINING, THE WALLS SHALL BE REPAIRED TO MATCH

ORIGINAL CONDITIONS.

8. WHERE EXISTING PIPING TO BE REMOVED PASSES THROUGH FLOORS, THEY

SHALL BE CUT BACK TO WITHIN CONCRETE AND FILLED WITH GROUT TO

ACHIEVE A SMOOTH AND EVEN FINISH WITH CONCRETE SURFACE.

HVAC PLAN NOTES:

1. ALL SUPPLY AIR DIFFUSERS ARE 4-WAY AIR PATTERN UNLESS SHOWN

OTHERWISE.

2. DUCT SIZE OF BRANCH DUCT TO AIR DEVICE SHALL BE THE SAME SIZE AS

NECK SIZE OF AIR DEVICE UNLESS NOTED OTHERWISE.

3. ALL HEATING WATER SUPPLY AND RETURN BRANCH PIPING TO TERMINAL

BOXES SHALL BE 3/4" UNLESS NOTED OTHERWISE. ALL PIPING TAKE-OFFS

FROM MAINS SHALL BE TOP TAKE-OFFS WITH SWING JOINTS.

4. BRANCH DUCT SIZE TO INLET OF ALL TERMINAL BOXES SHALL BE THE SAME

SIZE AS THE INLET SCHEDULED UNLESS NOTED OTHERWISE. BRANCH DUCTS

TO TERMINAL BOXES EXCEEDING 15' OR TWO ELBOWS, SHALL BE UP-SIZED TO

NEXT STANDARD DIAMETER.

5. UNLESS OTHERWISE NOTED, ALL SUPPLY AIR DUCTWORK SHALL BE

EXTERNALLY WRAPPED TO THICKNESS AS STATED IN SPECIFICATIONS AND

RETURN AND EXHAUST DUCTWORK IS NEITHER LINED NOR WRAPPED.

6. PROVIDE ROOM AIR BALANCE TO ACHIEVE POSITIVE (+) OR NEGATIVE (-) AT

THE DIFFERENTIAL PRESSURE INDICATED ON THE DRAWINGS.

7. PROVIDE EOMD AT ALL LOW POINTS FOR STEAM SUPPLY PIPING AS REQUIRED

WHICH MAY NOT NECESSARILY BE SHOWN.

8. ALL BRANCH STEAM SUPPLY AND CONDENSATE RETURN PIPING FROM MAINS

SHALL BE TOP TAKE-OFFS WITH SWING JOINTS.

9. REFER TO ARCHITECTURAL DRAWINGS FOR ROOF PENETRATION DETAILS.

10. DUCT SIZES INDICATED ARE SHEET METAL SIZES. WHERE INTERNAL DUCT

LINING IS PROVIDED, SHEET METAL SHALL NOT BE INCREASED IN SIZE.

UNLESS NOTED OTHERWISE ALL SCHEDULED DATA IS LISTED AT ELEVATION 7,550 FT

Mechanical

WAITING AREA

133A

OFFICE

131 C

OFFICE

131 B

OFFICE

131 A

X-RAY ROOM

133B

2-2

TB

x1 S

A x2 S

A

(E

(E

A

A

22x22 B

A

(TYP. OF 2)

A

M5M5

M9

M9

T

M10

S

M8

OFFICE

131 A

OFFICE

131 B

OFFICE

131 C x2 S

A (E

)1 x1 S

A (E

A

A

A

(TYP. OF 2)

A

22x22

B

22x22 B

2-2

TB

M1

M9 M5M5

T

SM7

No. Date Revision

© Hord Coplan Macht, Inc.

ARCHITECTURE

LANDSCAPE ARCHITECTURE

PLANNING

INTERIOR DESIGN

Drawing

Drawn By

Date (YYYY/MM/DD)

ARCHITECT

Project Number

Project Name

A

B

C

D

E

654321

Checked By

M/E/P ENGINEER

Cator Ruma & Associates Co 896 Tabor St #1 Lakewood, CO 80401

p. 303. 232. 6200

Hord Coplan Macht, Inc.

1800 Wazee Street, Suite 450 Denver, CO 80202

p. 303.607.0977

f. 303.607.0767

/5

/2

:1

:1

A

M

E D

W A

R D

S R

A D

IO

L

O G

Y L

A B

R E

N O

V A

T

IO

N M ill e r

R a n c h R d E d w a rd s C

O

P

C M

C \V a il

V a lle y a t E d w a rd s \2

-1

R a d io lo g y

R e n o va ti o n \C a d

CONSTRUCTION

DOCUMENTS

2024/11/05

RWL

C O

L O

R A

D O

M O

U N

T A

IN

C

O L L E

G E

224089

M-111

FIRST FLOOR MECHANICAL

PLANS

EDWARDS RADIOLOGY LAB

RENOVATION

LKL

KEYNOTES

M1 IT IS NOT THE INTENT TO RELOCATE OR REPLACE EXISTING HVAC CEILING

DEVICES. CONTRACTOR SHALL PROTECT EXISTING DEVICES DURING

CONSTRUCTION, WHICH MAY INVOLVE REMOVING PORTIONS OF THE

EXISTING CEILINGS.

M5 INSTALL NEW SPRINKLER HEADS AS REQUIRED TO MEET COVERAGE

REQUIREMENTS FOR RENOVATED SPACE.

M7 REMOVE AND SALVAGE EXISTING OCCUPANCY SENSOR IN THIS

LOCATION.

M8 REINSTALL EXISTING, SALVAGED OCCUPANCY SENSOR IN THIS LOCATION.

RECONNECT TO BAS SUCH THAT EXISTING FUNCIONALITY IS MAINTAINED.

DO NOT RECONNECT TO LIGHTING CONTROL SYSTEM, SINCE THAT

FUNCTIONALITY IS NOT REQUIRED FOR THE NEW SPACE PROGRAM. RE:

ELECTRICAL FOR ADDITIONAL INFORMATION.

M9 REMOVE AND SALVAGE EXISTING THERMOSTAT IN THIS LOCATION.

M10 RELOCATE EXISTING, SALVAGED THERMOSTAT TO COORDINATE WITH

NEW DOOR FRAME. INCLUDE PULLING FULL RUN OF NEW WIRE FOR

RELOCATED THERMOSTAT.

SCALE: 1/4" = 1'-0"

FIRST FLOOR MECHANICAL PLAN

SCALE: 1/4" = 1'-0"

FIRST FLOOR MECHANICAL DEMOLITION PLAN

Mechanical

ABBREVIATIONS LEGEND

AMPERES

ABOVE FINISHED FLOOR

ABOVE FINISHED GRADE

ANNUNCIATOR

ABOVE RAISED FLOOR

AIR SAMPLING SMOKE DETECTION

AUTOMATIC TRANSFER SWITCH

BELOW FINISHED GRADE

MOTOR CIRCUIT PROTECTOR

SEE MECHANICAL EQUIPMENT SCHEDULE

MINIMUM

MAIN LUGS ONLY

MANUAL TRANSFER SWITCH

NORMALLY CLOSED

NIGHT LIGHT

NORMALLY OPEN

NOT TO SCALECONDUIT

CABLE TELEVISION

CIRCUIT BREAKER

CLOSED CIRCUIT TELEVISION

EXISTING

EMERGENCY

EMERGENCY MAIN DISTRIBUTION CENTER

EXPLOSION PROOF

EMERGENCY POWER OFF

EMERGENCY VENTILATION ON/OFF

ELECTRIC WATER COOLER

FIRE ALARM

GROUND

GENERATOR CONTROL PANEL

GROUND FAULT CIRCUIT INTERRUPTER

HAND OFF AUTOMATIC

ISOLATED GROUND

MAXIMUM

MAIN CIRCUIT BREAKER

MOTOR CONTROL CENTER

MAIN DISTRIBUTION CENTER TRANSFORMER

WEATHER PROOF

WITHOUT

WITH

VARIABLE FREQUENCY DRIVE

VOLTS

UNINTERRUPTIBLE POWER SUPPLY

UNLESS OTHERWISE NOTED

UNDER GROUND

UNDER FLOOR

TYPICAL

TRANSIENT VOLTAGE SURGE SUPPRESSER

TAMPER PROOF

SUB-DISTRIBUTION CENTER

STAND-BY

PULL BOX

ON SITE WORK FORCE

OWNER FURNISHED, OWNER INSTALLED

OWNER FURNISHED, CONTRACTOR INSTALLED

ON CENTER

ABOVE COUNTER, MOUNT HORIZONTALLY TO CENTERLINE OF DEVICE,

+6" ABOVE COUNTER OR BACK SPLASH

NOT IN CONTRACT

DESCRIPTIONSYMBOL DESCRIPTIONSYMBOL

(Not all symbols listed below are used on these drawings)

MDC

MCC

MCB

MAX

IG

HOA

GFCI

GCP

G

FA

EWC

EVO

EPO

EP

EMDC

EM

(E)

CCTV

CB

CATV

C

BFG

ATS

ASSD

ARF

ANN

AFG

AFF

AC

A

XFMR

WP

W/O

W/

VFD

V

UPS

UON

UG

UF

TYP

TVSS

TP

SDC

SB

PB

OSWF

OFOI

OFCI

OC

NTS

NO

NL

NIC

NC

MTS

MLO

MIN

MEC

MCP

SINGLE POLE SWITCH (SUBSCRIPT DENOTES SWITCHING)

TWO POLE SWITCH

THREE-WAY SWITCH

FOUR-WAY SWITCH

KEY OPERATED SWITCH

MANUAL SWITCH, HORSEPOWER RATE

DIMMER SWITCH

LOW VOLTAGE SWITCH

VARIABLE SPEED/SPEED CONTROLLER SWITCH

EXPLOSION PROOF SWITCH

THERMAL OVERLOAD SWITCH

MOMENTARY CONTACT SWITCH

COMBINATION SWITCH AND DUPLEX RECEPTACLE

PHOTOCELL

TIME CLOCK

SWITCH WITH PILOT LIGHT LOCATOR

(CONTINUOUSLY LIGHTED HANDLE)

PUSH BUTTON

OCCUPANCY SENSOR - WALL MOUNTED

IR=INFRARED, US=ULTRASONIC, DT=DUAL TECHNOLOGY

S a

S

S

S

S K

S M

SD

SPI

SP

SLV

S

VS

S

EP

S

TO

S

MC

S

TC

CONTROLS LEGEND

DESCRIPTIONSYMBOL DESCRIPTIONSYMBOL

(Not all symbols listed below are used on these drawings)

P

SWITCH WITH PILOT LIGHT

(PILOT LIGHT IS 'ON' WHEN SWITCH IS 'ON')

ONE-LINE DIAGRAM LEGEND

(Not all symbols listed below are used on these drawings)

DISCONNECT SWITCH

DISCONNECT SWITCH, FUSED

CIRCUIT BREAKER

PANELBOARD "A"

EM=ENERGY METER, PM=POWER METER, CM=CIRCUIT MONITOR

VOLTMETER TEST SWITCH

AMMETER TEST SWITCH

VOLTMETER

AMMETER

ENGINE GENERATOR

CONTACTOR/RELAY/CAPACITOR (AS NOTED)

TRANSFER SWITCH - ATS=AUTOMATIC, MTS=MANUAL

GROUND FAULT INTERRUPTER

SURGE PROTECTIVE DEVICE

SHUNT TRIP

TERMINATIONS LB=LOAD BREAK, NLB=NO LOAD BREAK

DRAW-OUT DEVICE

PLUG-IN DEVICE

ELECTRICALLY OPERATEDMECHANICAL INTERLOCK

ELECTRICAL INTERLOCK, SUBSCRIPT INDICATES INTERLOCKED GROUP

KIRK KEY INTERLOCK, SUBSCRIPT INDICATES INTERLOCKED GROUP

SHORT CIRCUIT CURRENT AVAILABLE

SERVICE WEATHERHEAD

EQUIPMENT ENCLOSURE

METER

SERVICE ENTRANCE TRANSFORMER

POTENTIAL TRANSFORMER

CURRENT TRANSFORMER

STEP DOWN TRANSFORMER, ## INDICATES KVA

GROUND

FUSE

K-RATED STEP DOWN TRANSFORMER

## INDICATES KVA, # INDICATES K RATING

DESCRIPTIONSYMBOL DESCRIPTIONSYMBOL

T

OR

ISCA

K a

E a

M

A

PM

VS

V

GFI

XXX

M

TK

AS

A

G

SPD

ST

EO

SEE FEEDER/MEC/TRANSFORMER SCHEDULES FOR FEEDER SIZE

POWER LEGEND

(Not all symbols listed below are used on these drawings)

SINGLE RECEPTACLE

DUPLEX RECEPTACLE; WALL, CEILING, FLOOR MOUNTED

DOUBLE DUPLEX RECEPTACLE; WALL, CEILING, FLOOR MOUNTED

DUPLEX RECEPTACLE, HALF CONTROLLED

SPECIAL RECEPTACLE; WALL, CEILING, FLOOR MOUNTED

JUNCTION BOX; WALL, CEILING, FLOOR MOUNTED

DISCONNECT SWITCH (NON-FUSED)

DISCONNECT SWITCH (FUSED)

VARIABLE SPEED DRIVE WITH DISCONNECT

UTILITY METER

ELECTRICAL PANELBOARD, CONTROL PANEL, OR OTHER CABINET AS NOTED

PLUG MOLD (MULTI-OUTLET ASSEMBLY)

CONDUIT TURNING DOWN

CONDUIT TURNING UP

CONDUIT CAPPED

MAIN SWITCHBOARD/DISTRIBUTION CENTER

CURRENT TRANSFORMER

GENERATOR ANNUNCIATOR PANEL

CONDUIT, UNDERGROUND OR CONCEALED IN FLOOR

AS ALLOWED PER SPECIFICATIONS

DESCRIPTIONSYMBOL DESCRIPTIONSYMBOL

J

WM

T

CT

GANN

CONDUIT CONCEALED

GROUND BAR

TRANSFORMER

THERMOSTAT

A-1

T

PM

WIREMOLD (SURFACE RACEWAY)

SHADING INDICATES EMERGENCY SYSTEM

TEXT INDICATES PANEL AND CIRCUIT DESIGNATION

M

REFERENCE SYMBOLS LEGEND

(Not all symbols listed below are used on these drawings)

KITCHEN/OWNER/MEDICAL EQUIPMENT REFERENCE

MECHANICAL EQUIPMENT REFERENCE

EXISTING TO REMAIN

EXISTING TO BE REMOVED

EXISTING TO BE RELOCATED

EXISTING TO REMAIN - REPLACE DEVICE

DESCRIPTION DESCRIPTIONSYMBOL

X

LC1

UH

E

R

RL

ER

SYMBOL

KEY NOTE REFERENCE

LPA-# TYPICAL CIRCUIT NUMBER

TYPICAL LUMINAIRE TYPE

TG#

LIGHTING CONTROL / EQUIPMENT REFERENCE

TYPICAL ROOM REFERENCE (TOP = RM #, BOTTOM = FLR)

X X

EXISTING TO BE REMOVED AND REPLACEDRR

ENCLOSED CIRCUIT BREAKER

TOGGLE SWITCHS

LINEAR LUMINAIRE - RECESSED

TROFFER - RECESSED

EXIT SIGN - CEILING MOUNTED

EMERGENCY LIGHTING UNIT - WALL MOUNTED

EXTERIOR STAKE MOUNTED

INDICATES DIRECTIONAL AIMING

A a

SHADING INDICATES EM SYSTEM, LOWER CASE SUBSCRIPT

INDICATES SWITCHING, UPPER CASE SUBSCRIPT INDICATES

LUMINAIRE TYPE (TYP)

LIGHTING LEGEND

DESCRIPTIONSYMBOL DESCRIPTIONSYMBOL

(Not all symbols listed below are used on these drawings)

TRACK HEAD AND TRACK

DOWNLIGHT - RECESSED

DOWNLIGHT - SURFACE

PENDANT LUMINAIRE - MULTIPLE SUSPENSION

WALL MOUNTED LUMINAIRE

EMERGENCY LIGHTING UNIT - CEILING MOUNTED

EXIT SIGN - WALL MOUNTED (FLUSH TO WALL)

EXIT SIGN - WALL MOUNTED (PROJECTS FROM WALL)

INDICATES EXIT SIGN FACES - SINGLE OR DOUBLE

INDICATES EXIT SIGN CHEVRONS - LEFT/RIGHT OR BOTH

FIELD MEASURED LUMINAIRE

LENGTH AND SHAPE DENOTED BY LINEWORK

SUBSCRIPT IN RECTANGLE INDICATES LUMINAIRE TYPE

SURFACE LUMINAIRE

PENDANT LUMINAIRE - SINGLE SUSPENSION

IN-WALL LUMINAIRE

POLE LUMINAIRE - ARM MOUNTED

POLE LUMINAIRE - POST TOP

A

B

BOLLARD

UG

LC1 ELECTRICAL ACCESSORIES REFERENCE

POWER POLE

FIRE ALARM SYSTEM LEGEND

(Not all symbols listed below are used on these drawings)

FIRE ALARM CONTROL PANEL

FIRE ALARM REMOTE ANNUNCIATOR PANEL (LCD)

MANUAL PULL STATION

ADDRESSABLE INPUT MODULE

ADDRESSABLE OUTPUT MODULE

SMOKE ALARM (120 VAC SINGLE STATION)

SMOKE DETECTOR (P=PHOTOELECTRIC, SB=WITH SOUNDER

BASE, BR=BEAM RECEIVER, BT=BEAM TRANSMITTER)

FIRE ALARM ANNUNCIATOR PANEL (LED)

DUCT SMOKE DETECTOR S=SUPPLY, R=RETURN

DUCT DETECTOR REMOTE INDICATOR ALARM AND TEST

REMOTE INDICATOR LIGHT

CARBON MONOXIDE ALARM/DETECTOR

FLOW DETECTOR SWITCH

TAMPER SWITCH

MAGNETIC DOOR HOLD

FIRE ALARM STROBE (cd= CANDELA RATING 15, 30, 75, 95, 110, 177)

FIRE ALARM HORN (C = CEILING MOUNT))

DESCRIPTION DESCRIPTION

FACP

NAC

LCD

FAA

RACP

FFSC

RTS

F

F

SYMBOL

AIM

SYMBOL

FIRE FIGHTER SMOKE CONTROL PANEL

RESCUE ASSISTANCE SYSTEM BASE UNIT

FIRE ALARM (NAC) POWER SUPPLY

FIRE ALARM TRANSPONDER PANELTPR

RESCUE ASSISTANCE TELEPHONE STATIONRA

CO

PRESSURE SWITCHFIRE/SMOKE DAMPER

GRAPHIC ZONE MAPMAP

AOM

C

FIRE ALARM SPEAKER (C = CEILING MOUNT))FC

MASS NOTIFICATION SPEAKER (C = CEILING MOUNT))MC

S X

SS

ARCM AREA OF REFUGE COMMUNICATION MASTER UNIT

S X

S X

HEAT DETECTOR (F = FIXED TEMPERATURE, R = RATE OF RISE)H

X

H X

SS

FIRE FIGHTER TELEPHONE (J = JACK, H = HANDSET)X

S

RI RI

DH

15cd 15cd

FIRE ALARM HORN/VISIBLE (C = CEILING MOUNT))C

FIRE ALARM SPEAKER/VISIBLE (C = CEILING MOUNT))C

SURGE SUPPRESSOR

MASS NOTIFICATION SPEAKER/VISIBLE (C = CEILING MOUNT))C

M

MASS NOTIFICATION STROBE (cd= CANDELA RATING 15, 30, 75, 95, 110, 177) 15cd 15cd

M M

AREA OF REFUGE COMMUNICATION REMOTE UNITARCR

SMOKE DAMPERS

FLAME DETECTOR (UV=ULTRAVIOLET, IR=INFRARED)X

DH

VS

WF

PS

SS

CO X

JJ

DUPLEX RECEPTACLE, FULL CONTROLLED

DOUBLE DUPLEX RECEPTACLE, HALF CONTROLLED

DOUBLE DUPLEX RECEPTACLE, FULL CONTROLLED

SECURITY LEGEND

(Not all symbols listed below are used on these drawings)

WALL FIELD

ELECTRIC HINGE

LOCK OUT

ELECTRIC DOOR LOCK

ELECTRIC DOOR STRIKE

LOCK DOWN

DOOR RELEASE

DESCRIPTIONSYMBOLDESCRIPTIONSYMBOL

CR

CARD READER (XXX = SEE BELOW)

DOOR CONTACT

EH

LO

EL

ES

DR

LD

REQUEST TO EXITRX

INTERCOM DOOR STATIONIS

INTERCOM MASTER STATIONIM

MOTION DETECTOR

CEILING MOUNTED GLASS BREAK DETECTOR

GLASS BREAK DETECTOR

KEYPAD

GB

KP

MD

GB

DURESS ALARMDA

CEILING MOUNTED MOTION DETECTOR MD

FIXED PTZ SECURITY CAMERA CLG MOUNTED(XX=CAMERA SCHEDULE

NUMBER)

SECURITY CAMERA FIELD OF VIEW

XXX

BIO = BIOMETRIC

IL = INTEGRATED LOCK

KP = INTEGRATED KEYPAD

DOOR AUTO OPENERAO

PUSH PADPP

CB = CODE BLUE ELEVATOR CALL

XX

XX MULTI SENSOR SECURITY CAMERA (XX=CAMERA SCHEDULE NUMBER)

EMERGENCY CALL BOXECB

FIXED SECURITY CAMERA WALL MOUNTED(XX=CAMERA SCHEDULE

NUMBER)

XX

ELECTRIC POWER TRANSFER

POWER SUPPLY

MAGNETIC DOOR LOCK

EP

ML

PS

TECHNOLOGY LEGEND

(Not all symbols listed below are used on these drawings)

WALL FIELD

WIRE BASKET TRAY

DESCRIPTIONSYMBOLDESCRIPTIONSYMBOL

DATA OUTLET (# = QTY OF CABLES; XXX = SEE BELOW ZZ = ELEVATION)#

XXX

ZZ

POKE-THRU (# = QTY OF CABLES)#

XXX

CEILING MOUNTED OUTLET (# = QTY OF CABLES; XXX= SEE BELOW)

XXX

ZZ

WALL MOUNTED JBOX (XXX = SEE BELOW; ZZ = ELEVATION)

J

J FLOOR JBOX

DISTRIBUTED ANTENNA SYSTEM DAS

POKE THRU; (XXX = SEE BELOW)

J XXX

DATA POWER POLE (XXX = SEE BELOW)

T

XXX

FLOOR SPACE BOX DATA OUTLET(# = QTY OF CABLES)#

CLOCK OUTLET (XXX = SEE BELOW)

C

TELECOM GROUND BAR

D = MEDICAL/SUPPLY DISPENSER

EEG = EEG NETWORK

EP = EMERGENCY PHONE

F = FACP

RED = RED PHONE

T = TRANSLATION PHONE

TC = TIME CLOCK

POS = POINT OF SALE

W = WALL PHONE

RAD = RADIOLOGY NETWORK

C CEILING MOUNTED CLOCK

CABLE TRAY

AV = AUDIO VISUAL

XXX

AV = AUDIO VISUAL

WAP=WIRELESS ACCESS POINT PRJ = PROJECTOR

FF = FURNITURE FEED AV = AUDIO VISUAL

CLG = CEILING AV = AUDIO VISUAL

DS = DOUBLE SIDED

SR = SURFACE RUNWAY

PRT = PRINTER

BAS = BUILDING

AUTOMATION SYSTEM

MFP = MULTI FUNCTIONS PRINTER

SCH = SCHEDULER

WP = WEATHER PROOF

SEC = SECURITY

J J J J-HOOK PATHWAY

C S XXX

COMBINATION CLOCK/SPEAKER OUTLET (XXX = SEE BELOW)

A = ANALOG D = DIGITAL

DIGITAL (PROVIDE 1 CAT 6 CONNECTION)

A = ANALOG

PB YY PULLBOX (YY = SIZE)

WAP WIRELESS ACCESS POINT ENCLOSURE

SR = SURFACE RACEWAY

SEC = SECURITY

SEC = SECURITY

CP = CONTROL PANEL CLK = CLOCK

TELEVISION COAXIAL CABLE (ZZ = ELEVATION)ZZ

CEILING MOUNTED TELEVISION COAXIAL OUTLET

EQUIPMENT RACK

WIRE MANAGER

CABINET

No. Date Revision

© Hord Coplan Macht, Inc.

ARCHITECTURE

LANDSCAPE ARCHITECTURE

PLANNING

INTERIOR DESIGN

Drawing

Drawn By

Date (YYYY/MM/DD)

ARCHITECT

Project Number

Project Name

A

B

C

D

E

654321

Checked By

M/E/P ENGINEER

Cator Ruma & Associates Co 896 Tabor St #1 Lakewood, CO 80401

p. 303. 232. 6200

Hord Coplan Macht, Inc.

1800 Wazee Street, Suite 450 Denver, CO 80202

p. 303.607.0977

f. 303.607.0767

/5

/2

:3

:0

A

M

E D

W A

R D

S R

A D

IO

L

O G

Y L

A B

R E

N O

V A

T

IO

N M ill e r

R a n c h R d E d w a rd s C

O

P

C M

C \V a il

V a lle y a t E d w a rd s \2

-1

R a d io lo g y R e n o v a ti o n \C a d

CONSTRUCTION

DOCUMENTS

2024/11/05

PDT

C O

L O

R A

D O

M O

U N

T A

IN

C

O L L E

G E

224089

E-001

ELECTRICAL LEGENDS &

NOTES

EDWARDS RADIOLOGY LAB

RENOVATION

KPC

GENERAL NOTES:

1. FOR REMODELING, WORK INCLUDED IS DENOTED IN BOLD. EXISTING

CONDITIONS TO REMAIN ARE DENOTED LIGHTLY.

2. PROTECT STRUCTURE AND OWNER EQUIPMENT FROM DAMAGE. IMMEDIATELY

REPLACE OR REPAIR, TO ORIGINAL CONDITION, DAMAGE CAUSED BY THE

CONTRACTOR WHETHER EQUIPMENT APPEARS TO BE CURRENTLY IN USE OR

NOT, UNLESS WRITTEN AUTHORIZATION FROM THE OWNER INDICATED

OTHERWISE. PREPARE LISTING OF ALL EXISTING DAMAGED ITEMS AND SUBMIT

TO OWNER PRIOR TO BEGINNING WORK.

3. INSTALL CONDUIT CONCEALED IN FINISHED AREAS UNLESS OTHERWISE NOTED.

PAINT EXPOSED CONDUIT TO MATCH EXISTING FINISHES WITHIN THE

SURROUNDING AREA.

4. DO NOT ROUTE CONDUIT WITHIN STRUCTURAL OR TOPPING SLABS OF FLOORS

UNLESS SPECIFICALLY NOTED OTHERWISE AND WRITTEN APPROVAL IS

OBTAINED FROM THE STRUCTURAL ENGINEER.

5. FIRE SEAL ALL FIRE RATED WALL AND FLOOR PENETRATIONS. REFER TO

ARCHITECTURAL DRAWINGS FOR FIRE RATED WALLS.

6. EXISTING INFORMATION SHOWN ON THE DRAWINGS HAS BEEN TAKEN FROM

OWNER FURNISHED DRAWINGS AND/OR LIMITED FIELD OBSERVATIONS. CATOR,

RUMA & ASSOCIATES IS NOT RESPONSIBLE FOR THE ACCURACY OF ANY

INFORMATION OR THE ADEQUACY, SAFETY AND CONFORMANCE TO CURRENT

PREVAILING CODES OF ANY WORK SHOWN AS EXISTING ON THESE DRAWINGS.

7. PROVIDE SEPARATE INSULATED EQUIPMENT GROUNDING CONDUCTOR IN ALL

FEEDER, HOMERUN AND BRANCH CIRCUITS.

DEMOLITION NOTES:

1. UNLESS NOTED OTHERWISE, BOLD ITEMS INDICATE EQUIPMENT, DEVICES,

ETC. TO BE REMOVED. SEE SPECIFICATION SECTION 260500 FOR

REMODEL/DEMOLITION DETAILED REQUIREMENTS.

2. DEMOLITION DRAWINGS MAY NOT SHOW EVERY ITEM TO BE DEMOLISHED.

CONTRACTOR SHALL VISIT SITE TO DETERMINE AND COORDINATE THE EXACT

EXTENT OF DEMOLITION TO FACILITATE ALL WORK INDICATED BY THE

CONTRACT DOCUMENTS PRIOR TO QUOTATION. NO EXTRAS WILL BE

ALLOWED FOR WORK REQUIRED TO ACHIEVE THE END RESULT AS INDICATED

BY THE CONTRACT DOCUMENTS. REWORK EXISTING TERMINATIONS,

CONNECTIONS, CONDUIT, WIRING, ETC. TO ACCEPT NEW WORK. MAINTAIN

CIRCUIT CONTINUITY TO EXISTING CIRCUITS AND DEVICES TO REMAIN OR

REMODEL/DEMOLITION DETAILED REQUIREMENTS TO BE RELOCATED. PRIOR

TO COMMENCEMENT OF ANY DEMO WORK, CONFIRM EXISTING CONDITIONS

AND NOTIFY ENGINEER OF ANY DISCREPANCIES FOR RESOLUTION.

3. ALL ITEMS IDENTIFIED…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .