CHR Reference Dwgs Photos.pdf

PDF 8 MB Posted

Attached to
Chaleroi Elevator Modernization Federal contract opportunity
Solicitation number
W911WN23B8022
Issued by
Department of the Army Corps of Engineers Engineering District Pittsburgh

About this file

This document includes a federal contract opportunity solicitation for an elevator modernization project and reference files. The U.S. Army Corps of Engineers, Pittsburgh District, is seeking to refurbish the electrical geared traction elevator at the Monongahela River Charleroi Locks and Dam in Westmoreland County, Pennsylvania. Major work includes removing and replacing the elevator driving machine, controls, wiring, fixtures, cables, governor assembly, and installing an air conditioning unit and associated controls in the machine room. Additional requirements are upgrading light fixtures, receptacles, and the disconnect switch as well as installing detectors in the hoistway, machine rooms, and lobby areas. The small business set-aside is $22 million. The anticipated award date is mid-August with a magnitude cost range of $250,000 to $500,000 and a completion time of less than 270 days. Interested firms must be registered in SAM and PIEE with the proposal manager role. Reference files of drawings and photos are provided but have been reduced in size.

View the file

Other files for this federal contract opportunity

Other files attached to Chaleroi Elevator Modernization, newest first.
File Type Posted
Bid Results List Bid Opening.pdf PDF
W911WN23B8022 Amendment 2.pdf PDF
DBA WD 06232023.gov.pdf PDF
CHR Site Visit Sign in Sheet.pdf PDF
W911WN23B8022 0001.pdf PDF
DBA WD 06152023.gov.pdf PDF
CHR Elevator Modernization_Technical Specification.pdf PDF
W911WN23B8022 06212023.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

REFERENCE DRAWINGS

(FILES BEEN REDUCED, ORIGINAL IS AVAILABLE UPON REQUEST)

SERVICE TRANSFORMER

ORIGINAL MIDDLE WALL

BRIDGE

DAM SERVICE

DAM PIER

POWERHOUSE

LAND WALL

SERVICE BUILDING

OPERATIONS BUILDING

TOWER

ACCESS

FOOTBRIDGE

FOOTBRIDGE

ESPLANADE

NEW CONTROL TOWERCONTROL SHELTER

NEW UPSTREAM

NEW FOOTBRIDGE

NEW MIDDLE WALL

RIVER WALL

LAND WALL

CONTROL SHELTER

NEW DOWNSTREAM

C

C

E

C

E

E

IP

P W

P :d m s

A O

L

C H

A

.d g n

H

T S

D E

S Q

A U

G

:5

A O

L

C H

A

.d g n

.0

:1

C

M

IL

L E

R

E L E

C T

R

IC

A L S

Y S

T E

M S

R O

N A

L D

R

G A

D O

M S

K I

D

N G

U Y

E N

L O

C K W

A L L S P

L A

N

O V

E R

A L L

FLOW

MONONGAHELA RIVERNN

80’0 40’

SCALE: 1"=40’

UPPER AND LOWER GUARD WALLS NOT SHOWN.2.

ALL IS EXISTING UNLESS OTHERWISE NOTED.1.

NOTES:

FLOW

SCALE: 1"=40’

LOCK WALLS PLAN - OVERALL

A29/230 s

J

O H

N

N

IT

E S

P .E

A P

S O

L

IC

IT

A T

IO

N N

O

F

IL

E N

A M

E

D W

N B

Y

C K

D B

Y

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

D

2 3

C

4 5

A

B

M A

R K

A P

P R

NUMBER

IDENTIFICATION

SHEET

OF ENGINEERS

US ARMY CORPS

D A

T E

F

IL

E N

U M

B E

R

S

IZ

E

S U

B M

IT

T E

D B

Y

P L

O T S

C A

L E

P L

O T D

A T

E

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N A

P P

R

D A

T E

C O

N T

R A

C T N

O

C O

R P

S O

F E

N G

IN

E E

R S

U S

A R

M Y E

N G

IN

E E

R D

IS

T R

IC

T

M O

N O

N G

A H

E L

A R

IV

E R

C H

A R

L E

R O I L

O C

K S A

N D D

A M

PITTSBURGH DISTRICT

P

IT

T S

B U

R G

H P

A

IV

E R C

H A

M B

E R C

O M

P L E

T

IO

N W

W N

B

AS-AWARDED CERTIFIED FINAL

W

W N

C

NEW RIVER CHAMBER

LAND CHAMBER

(ELEVATOR)

CONTRACTOR

WORK LIMIT

CONTRACTOR

LAY-DOWN AREA

H4ECNLJT

Rectangle

H4ECNLJT

Rectangle

H4ECNLJT

Callout

OUTDOOR COMPRESSOR/

CONDENSER UNIT (APPROX. SIZE 36"x24"x12) SUPPORTED AT 821.50 El

H4ECNLJT

Callout WALL-MOUNTED MINI-SPLIT INDOOR UNIT (APPROX. SIZE 36"x12"x8"

H4ECNLJT

Line

H4ECNLJT

Line

H4ECNLJT

Line

H4ECNLJT

Rectangle

H4ECNLJT

Line

H4ECNLJT

Line

H4ECNLJT

Line

H4ECNLJT

Callout

CONDENSATE LINE TO DRAIN TO LOWER ROOF DRAIN

H4ECDHLN

Rectangle

H4ECDHLN

Callout

EXISTING ELEVATOR DISCONNECT SWITCH

H4ECDHLN

Rectangle

H4ECDHLN

Callout NON-FUSED DISCONNECT SWITCH FOR CONDENSER UNIT MOUNT AT 820.50 El

PHOTOS

(FILE HAS BEEN REDUCED, ORIGINAL IS AVAILABLE UPON REQUEST)

File details come from the government source that posted it. Updated .