This document is a PVWatts Calculator analysis report provided by the National Lab of the Rockies (NLR), operated by the Alliance for Energy Innovation, LLC, for the U.S. Department of Energy (DOE). The report presents photovoltaic system performance predictions for a 234 kW DC solar installation located at latitude 38.21°N and longitude 84.86°W in the 40601 ZIP code area. The analysis utilizes 30 years of historical weather data from the National Solar Radiation Database (NSRDB) to project system output and interannual variability. The PV system is configured as a fixed open-rack array with a 20-degree tilt, 180-degree azimuth orientation, 1.2 DC-to-AC size ratio, and an estimated 14.08% total system losses including 96% inverter efficiency. No bidder meetings, site visits, response dates, or contract terms are specified in this technical analysis document.
The projected annual energy output for the system is 309,882 kWh per year, with a possible range of 293,056 to 322,959 kWh annually based on historical weather variability. Monthly output ranges from a low of 15,598 kWh in December to a peak of 33,447 kWh in June, with corresponding solar radiation values between 2.54 and 6.45 kWh/m²/day. The DC capacity factor is calculated at 15.1%, and the analysis indicates zero monthly irradiance losses across all months. The document includes a disclaimer indicating that the PVWatts Model is provided "as is" without warranties or liability, and notes that more sophisticated modeling tools such as the System Advisor Model are available for complex PV system analysis. No pricing information, funding sources, or contractual set-asides are included in this technical report.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Enhance PVWatts® with features tailored to your specific needs!
We collaborate with companies, universities, and organizations to privately fund new capabilities or analyses.
Your investment drives innovation while benefiting the broader energy community.
Email PVWatts@nlr.gov to learn more.
Caution: Photovoltaic system performance predictions calculated by PVWatts® include many inherent assumptions and uncertainties and do not reflect variations between PV technologies nor site-specific characteristics except as represented by PVWatts® inputs. For example, PV modules with better performance are not differentiated within PVWatts® from lesser performing modules. Both NLR and private companies provide more sophisticated PV modeling tools (such as the System Advisor Model at //sam.nlr.gov) that allow for more precise and complex modeling of PV systems.
The expected range is based on 30 years of actual weather data at the given location and is intended to provide an indication of the variation you might see. For more information, please refer to this NLR report:
The Error Report.
Disclaimer: The PVWatts® Model ("Model") is provided by the National Lab of the Rockies ("NLR"), which is operated by the Alliance for Energy Innovation, LLC ("Alliance") for the U.S. Department Of Energy ("DOE") and may be used for any purpose whatsoever.
The names DOE/NLR/ALLIANCE shall not be used in any representation, advertising, publicity or other manner whatsoever to endorse or promote any entity that adopts or uses the Model. DOE/NLR/ALLIANCE shall not provide any support, consulting, training or assistance of any kind with regard to the use of the Model or any updates, revisions or new versions of the Model.
YOU AGREE TO INDEMNIFY
DOE/NLR/ALLIANCE, AND ITS AFFILIATES,
OFFICERS, AGENTS, AND EMPLOYEES
AGAINST ANY CLAIM OR DEMAND,
INCLUDING REASONABLE ATTORNEYS'
FEES, RELATED TO YOUR USE, RELIANCE,
OR ADOPTION OF THE MODEL FOR ANY
PURPOSE WHATSOEVER. THE MODEL IS
PROVIDED BY DOE/NLR/ALLIANCE 'AS IS'
AND ANY EXPRESS OR IMPLIED
WARRANTIES, INCLUDING BUT NOT
LIMITED TO THE IMPLIED WARRANTIES OF
MERCHANTABILITY AND FITNESS FOR A
PARTICULAR PURPOSE ARE EXPRESSLY
DISCLAIMED. IN NO EVENT SHALL
DOE/NLR/ALLIANCE BE LIABLE FOR ANY
SPECIAL, INDIRECT OR CONSEQUENTIAL
DAMAGES OR ANY DAMAGES WHATSOEVER,
INCLUDING BUT NOT LIMITED TO CLAIMS
ASSOCIATED WITH THE LOSS OF DATA OR
PROFITS, WHICH MAY RESULT FROM ANY
ACTION IN CONTRACT, NEGLIGENCE OR
OTHER TORTIOUS CLAIM THAT ARISES OUT
OF OR IN CONNECTION WITH THE USE OR
PERFORMANCE OF THE MODEL.
The energy output range is based on analysis of 30 years of historical weather data, and is intended to provide an indication of the possible interannual variability in generation for a Fixed (open rack) PV system at this location.
309,882 kWh/Year*
RESULTS
System output may range from 293,056 to 322,959 kWh per year near this location.
Month Solar Radiation ( kWh / m2 / day )
AC Energy ( kWh )
January 2.93 18,124
February 3.58 19,498
March 4.23 24,759
April 5.23 28,404
May 5.83 32,155
June 6.45 33,447
July 6.16 32,679
August 5.94 32,001
September 5.42 28,577
October 4.41 24,995
November 3.40 19,643
December 2.54 15,598
Annual 4.68 309,880
Location and Station Identification
Requested Location 40601, USA
Solar Resource Data Location NSRDB Lat/Lng: 38.21, -84.86
Latitude 38.21° N
Longitude 84.86° W
PV System Specifications
DC System Size 234 kW
Module Type Standard
Array Type Fixed (open rack)
System Losses 14.08%
Array Tilt 20°
Array Azimuth 180°
DC to AC Size Ratio 1.2
Inverter Efficiency 96%
Ground Coverage Ratio 0.4
Albedo From weather file
Bifacial No (0) mailto:PVWatts@nlr.gov?subject=Funding%20PV%20Watts%20Enhancement%20Inquiry
Monthly Irradiance Loss
Jan Feb Mar Apr May June 0% 0% 0% 0% 0% 0%
July Aug Sept Oct Nov Dec 0% 0% 0% 0% 0% 0%
Performance Metrics
DC Capacity Factor 15.1%