This technical drawing is a detailed engineering specification for a BL09 2-Piece Fine Radial Collimator (FRC) assembly for the Corelli instrument at Oak Ridge National Laboratory's Spallation Neutron Source. The drawing (BL09-20-M8U-8709-A10000) depicts a two-piece component with specific design requirements for neutron beam optics, featuring sides A and B with precise geometric configurations. The design includes an 8x tap drill through specification (M10x1.5 6H .8), a central vertical axis, and neutron beam directionality, with tolerances specified for dimensions and surface roughness. The drawing is marked as revision B, with an original issue date of 5/12/2025, and indicates a total weight of 329 LB for the assembly.
The technical specification emphasizes critical manufacturing notes, including that vendors and vendor-specific items cannot be substituted without prior engineering approval. The drawing uses third-angle projection and adheres to drafting standards including ASME Y14.100, Y14.5, and AWS A2.4 welding symbols. The component is part of the FTS Instrument for BL09 Corelli, with specific requirements and dimensions that are either fixed, flexible, or within defined ranges as detailed in a referenced document (BL09-20-EQS10000-R01).
View the file
Other files
| File | Type | Posted |
|---|---|---|
| BL09-20-EQS10000-R01.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
7 6 5 4 3 2 18
7 6 5 4 3 2 18
A
C
D
A
B
C
D
B
32.96
TO COLUMN FACE
25.0�$�
82.0�$�
97.0�$�
179.0�$�
29.00
124X 1.3�$�
4X .75
4X 3.00
R25.50
R16.50 248X .13
NO REPRESENTATION OR WARRANTY, EXPRESSED OR IMPLIED, IS MADE AS TO THE ACCURACY, COMPLETENESS OR USEFULNESS OF THE INFORMATION OR STATEMENTS CONTAINED IN THESE DRAWINGS, OR THAT THE DISCLOSURE OF ANY INFORMATION, APPARATUS, METHOD OR PROCESS DISCLOSED IN THESE DRAWINGS MAY NOT INFRINGE PRIVATE RIGHTS OF OTHERS. NO LIABILITY IS ASSUMED
WITH RESPECT TO THE USE OF, OR FOR DAMAGES RESULTING FROM THE USE OF, ANY INFORMATION, APPARATUS, METHOD OR PROCESS DISCLOSED IN THESE DRAWINGS. DRAWINGS MADE AVAILABLE FOR INFORMATION TO BIDDER ARE NOT TO BE USED FOR OTHER PURPOSES AND ARE TO BE RETURNED UPON REQUEST OF THE FORWARDING CONTRACTOR.
THIS DRAWING IS THE PROPERTY OF OAK RIDGE NATIONAL LABORATORY.
APPROVAL BLOCK
REV DESCRIPTION OF CHANGE DES CHK ENG AP1 AP2 AP3 DATE
0 ORIGINAL ISSUE PER DCR 1206073075943773 5/12/2025
NEXT USED ASSEMBLY
SING20920M8U8709A001
UNITS: INCHES
DEFAULT TOLERANCES
X.XX �#�.01
X.XXX �#�.005
ANGULAR �#�.5�$�
BREAK ALL SHARP EDGES
EXCEPT AS NOTED: .06 MAX
SURFACE
ROUGHNESS: 125 RMS U.N.O.
DRAFTING STD: ASME Y14.100
GDT: ASME Y14.5
WELD SYMBOLS: AWS A2.4
THIRD
ANGLE
PROJECTION
FTS INSTRUMENT - BL09 CORELLI
20 - OPTICS
BL09 2-PIECE FRC, 97 DEG & 80 DEG
DRAWING NUMBER REV
BL09-20-M8U-8709-A10000 B
SIZE SCALE WEIGHT SHEET
D 29:320 329 LB 1 of 1VENDOR
MATERIAL
SPECIFICATION
DESCRIPTION PART NUMBER QTY
FIND
NO.
BL09 2-PIECE FRC SIDE B BL09-20-M8U-8709-A10001 1 1
BL09 2-PIECE FRC SIDE A BL09-20-M8U-8709-A10002 1 2
NOTES:
1 VENDORS AND VENDOR SPECIFIC ITEMS MAY NOT BE SUBSTITUTED WITHOUT PRIOR ENGINEERING APPROVAL
2 REQUIREMENTS/DIMENSIONS THAT SHALL BE MET
3 REQUIREMENTS/DIMENSIONS THAT ARE FLEXIBLE
4 REQUIREMENTS/DIMENSION THAT CAN BE WITHIN A RANGE OR A MAXIMUM VALUE GIVEN IN BL09-20-EQS10000-R01
SECTION A-A
CENTRAL
VERTICAL AXIS
DIRECTION OF
NEUTRON BEAM
NEUTRON BEAM
8X
TAP DRILL THRU
M10x1.5 6H .8
| Sheet 1 |
| Views |
| FRONT |
| TOP |
| RIGHT |
| DWG_ISO |
| top_9 |
| bottom_10 |
| Zones |
| D8 |
| D7 |
| D6 |
| D5 |
| D4 |
| D3 |
| D2 |
| D1 |
| C8 |
| C7 |
| C6 |
| C5 |
| C4 |
| C3 |
| C2 |
| C1 |
| B8 |
| B7 |
| B6 |
| B5 |
| B4 |
| B3 |
| B2 |
| B1 |
| A8 |
| A7 |
| A6 |
| A5 |
| A4 |
| A3 |
| A2 |
| A1 |
File details come from the government source that posted it. Updated .