JOB# D0942
DATE: AUGUST 2024
*NOTICE*
THIS SET OF PLANS IS NOT VALID FOR CONSTRUCTION PURPOSES WITHOUT BEING STAMPED
"APPROVED FOR CONSTRUCTION BY CPH ENGINEERS, INC." PLANS WITHOUT THIS STAMP ARE GIVEN
FOR INFORMATIONAL PURPOSES ONLY.
c 2022
City Officials
NOTE: THE SCALE OF THESE PLANS MAY
HAVE CHANGED DUE TO REPRODUCTION
AERIAL
SCALE : 1" = 200'
DELAND, FLORIDA
SURVEYOR
OWNER
CITY OF DELAND,
120 S. FLORIDA AVENUE,
DELAND, FL 32720
(386) 626-7189
ATTN: RAY BAHRAMI, P.E.,
PMP, CPM, CFM
DEPUTY PUBLIC SERVICES
DIRECTOR/CITY ENGINEER
CPH CONSULTING, LLC
500 W. FULTON STREET,
SANFORD, FL 32771
(407) 322-6841
ATTN: THOMAS J. GALLOWAY, PSM
ENGINEER
CPH CONSULTING, LLC
500 W. FULTON STREET,
SANFORD, FL 32771
(407) 322-6841
ATTN: HOWARD L. WRAY, P.E.
CONSULTANTS
N www.sunshine811.com www.cphcorp.com
Architects Engineers
Environmental Landscape Architects
M / E / P Planners
Surveyors Traffic/Transportation
Offices In:
· Florida
· Puerto Rico
· Connecticut
· Maryland
· Texas
A Full Service A & E Firm
CPH CONSULTING, LLC
Arch. Lic. No. AA2600926 Landscp. Lic. No. LC0000298
Licenses:
Eng. C.O.A. No. 3215 Survey L.B. No. 7143
500 W. FULTON ST.
SANFORD, FL 32771
Phone: (407) 322-6841
Plans Prepared By:
LOCATION MAP
SCALE : 1" = 1000'
DELAND, FLORIDA
COMMISSIONERS
VICE-MAYOR CHARLES PAIVA, SEAT 2
JESSICA DAVIS, SEAT 3
DANIEL REED, SEAT 4
KEVIN REID, SEAT 5
MAYOR
CHRIS CLOUDMAN
CITY MANAGER
MICHAEL PLEUS, ICMA-CM
SITE LOCATION
DRAINAGE IMPROVEMENTS FOR
SPEC MARTIN MEMORIAL STADIUM
TAX DISTRICT 012, CITY OF DELAND
ARCHITECT
SITE LOCATION
C I T Y O F D E L A N D
Sheet No.
C0.0HOWARD L. WRAY
55557
CPH CONSULTING, LLC
500 W. FULTON STREET,
SANFORD, FL 32771
(407) 322-6841
ATTN: SIDNEY KETNER WEST II, AIA NCARB
INDEX OF SHEET
C0.0 COVER SHEET
C0.1 SIGNATURE SHEET
C0.2 GENERAL NOTES
V0.1 TOPOGRAPHIC SURVEY
V1.1 TOPOGRAPHIC SURVEY
V1.2 TOPOGRAPHIC SURVEY
C1.1 - C1.2 DEMOLITION PLAN
C1.3 - C1.4 STORMWATER POLLUTION PREVENTION PLAN
C1.5 STORMWATER POLLUTION PREVENTION DETAILS
C1.6 - C1.7 DRAINAGE PLAN
C1.8 DRAINAGE STRUCTURE SCHEDULE & CROSS SECTIONS
C1.9 - C2.0 GRADING PLAN
C2.1 - 2.3 GENERAL DETAILS
C2.4 CITY NOTES
A101 ARCHITECTURAL FLOOR PLAN (NORTH BUILDING)
A102 ARCHITECTURAL FLOOR PLAN (SOUTH BUILDING)
A103 ARCHITECTURAL FLOOR PLAN (WEST BUILDING)
A141 ROOF PLAN (NORTH BUILDING)
A142 ROOF PLAN (SOUTH BUILDING)
A201 EXTERIOR ELEVATIONS (NORTH BUILDING)
A202 EXTERIOR ELEVATIONS (WEST BUILDING)
A203 EXTERIOR ELEVATIONS (WEST BUILDING)
A204 EXTERIOR ELEVATIONS (SOUTH BUILDING)
A205 EXTERIOR ELEVATIONS (SOUTH BUILDING)
A330 GENERAL DETAILS (NORTH BUILDING)
A331 GENERAL DETAILS (WEST BUILDING)
THIS ITEM HAS BEEN DIGITALLY SIGNED AND SEALED BY:
THE ABOVE NAMED PROFESSIONAL ARCHITECT IS RESPONSIBLE FOR THE FOLLOWING
SHEETS IN ACCORDANCE WITH RULE 61G1-16, F.A.C.
THIS ITEM HAS BEEN DIGITALLY SIGNED AND SEALED BY:
ON THE DATE ADJACENT TO THE SEAL
PRINTED COPIES ARE NOT CONSIDERED SIGNED AND
SEALED AND THE SIGNATURE MUST BE VERIFIED ON
ANY ELECTRONIC COPIES.
500 W. FULTON ST.
SANFORD, FL 32771
THOMAS J. GALLOWAY, LS6549
THE ABOVE NAMED PROFESSIONAL SURVEYOR IS RESPONSIBLE FOR THE FOLLOWING
SHEETS IN ACCORDANCE WITH RULE 61G15-23.004, F.A.C.
SIDNEY KETNER WEST II THOMAS J. GALLOWAY
THIS ITEM HAS BEEN DIGITALLY SIGNED AND SEALED BY:
THE ABOVE NAMED PROFESSIONAL ENGINEER IS RESPONSIBLE FOR THE FOLLOWING
SHEETS IN ACCORDANCE WITH RULE 61G15-23.004, F.A.C.
HOWARD LAWRENCE WRAY, JR.
SHEET NO. DESCRIPTION
A101 ARCHITECTURAL FLOOR PLAN (NORTH BUILDING)
A102 ARCHITECTURAL FLOOR PLAN (SOUTH BUILDING)
A103 ARCHITECTURAL FLOOR PLAN (WEST BUILDING)
A141 ROOF PLAN (NORTH BUILDING)
A142 ROOF PLAN (SOUTH BUILDING)
A201 EXTERIOR ELEVATIONS (NORTH BUILDING)
A202 EXTERIOR ELEVATIONS (WEST BUILDING)
A203 EXTERIOR ELEVATIONS (WEST BUILDING)
A204 EXTERIOR ELEVATIONS (SOUTH BUILDING)
A205 EXTERIOR ELEVATIONS (SOUTH BUILDING)
A330 GENERAL DETAILS (NORTH BUILDING)
A331 GENERAL DETAILS (WEST BUILDING)
SHEET NO. DESCRIPTION
V0.1 TOPOGRAPHIC SURVEY
V1.1 TOPOGRAPHIC SURVEY
V1.2 TOPOGRAPHIC SURVEY
SHEET NO. DESCRIPTION
C0.0 COVER SHEET
C0.2 GENERAL NOTES
C1.1 - C1.2 DEMOLITION PLAN
C1.3 - C1.4 STORMWATER POLLUTION PREVENTION PLAN
C1.5 STORMWATER POLLUTION PREVENTION DETAILS
C1.6 - C1.7 DRAINAGE PLAN
C1.8 DRAINAGE STRUCTURE SCHEDULE & CROSS SECTIONS
C1.9 - C2.0 GRADING PLAN
C2.1 - 2.3 GENERAL DETAILS
C2.4 CITY NOTES
500 West Fulton Street Sanford, FL 32771 Ph: 407.322.6841
D at e N o.
R ev is io n mwww.cphcorp.co
123456
C 2025
THIS SHEET NOT VALID FOR
CONSTRUCTION WITHOUT
COMPLETE SET OF PLANS.
Sheet No.
Drawn:
Designed:
Checked:
Job No.:
Date:
SP
EC
M A
R
TI
N M
EM
O
R
IA
L
ST
A D
IU
M
0.
E . E uc lid
A ve
D eL an d, F lo rid a
D0942
Building Better Communities Together
CPH CONSULTING ,LLC
A Full Service A &E Firm
Plans Prepared By:
C0.1
SI
G
N A
TU
R
E
SH
EE
T
J. DYMEK
A. KHORRAMIAN
L. WRAY
09/03/2024
H O
W
AR
D L
. W R
AY
F.
L.
P
.E . N
O . 5
CPH CONSULTING, LLC
500 W. FULTON ST.
SANFORD, FL 32771
SIDNEY KETNER WEST II, AR102902
CPH CONSULTING, LLC
ON THE DATE ADJACENT TO THE SEAL
PRINTED COPIES ARE NOT CONSIDERED SIGNED AND
SEALED AND THE SIGNATURE MUST BE VERIFIED ON
ANY ELECTRONIC COPIES.
CPH CONSULTING, LLC
500 W. FULTON ST.
SANFORD, FL 32771
HOWARD L. WRAY, P.E. No. 55557 www.sunshine811.com
PIPE SEPARATION DETAILS
500 West Fulton Street Sanford, FL 32771 Ph: 407.322.6841
D at e N o.
R ev is io n www.cphcorp.com
123456
C 2025
THIS SHEET NOT VALID FOR
CONSTRUCTION WITHOUT
COMPLETE SET OF PLANS.
Sheet No.
Drawn:
Designed:
Checked:
Job No.:
Date:
SP
EC
M A
R
TI
N M
EM
O
R
IA
L
ST
A D
IU
M
0.
E . E uc lid
A ve
D eL an d, F lo rid a
D0942
Building Better Communities Together
,LLC
A Full Service A &E Firm
Plans Prepared By:
C0.2
G
EN
ER
A
L N
O
TE
S
J. DYMEK
J.SOTO
L. WRAY
09/03/2024
H O
W
AR
D L
. W R
AY
F.
L.
P
.E . N
O . 5
/0
4/
PE
R
C
IT
Y C
O M
M
EN
TS
/1
5/
PE
R
C
IT
Y C
O M
M
EN
TS
HOWARD L. WRAY, STATE OF FLORIDA,
PROFESSIONAL ENGINEER, LICENSE NO. 55557
THIS ITEM HAS BEEN DIGITALLY SIGNED AND
SEALED BY HOWARD L. WRAY ON THE DATE
INDICATED HERE. PRINTED COPIES OF THIS
DOCUMENT ARE NOT CONSIDERED SIGNED
AND SEALED AND THE SIGNATURE MUST BE
VERIFIED ON ANY ELECTRONIC COPIES.
GENERAL PROVISIONS
1. PRIOR TO CONSTRUCTION, THE CONTRACTOR SHALL MAKE A PRE-CONSTRUCTION VIDEO (DVD FORMAT) ALONG THE PROPOSED OF THE
CONSTRUCTION SITE AND ADJACENT AREAS IN ACCORDANCE WITH THE SPECIFICATIONS. IN PARTICULAR, THE VIDEO SHALL DOCUMENT THE CONDITION OF EXISTING DRIVEWAYS, BUILDINGS, STRUCTURES, SIGNS, FENCES, AND LANDSCAPING ALONG PROPOSED CONSTRUCTION AREAS.
2. THE CONTRACTOR SHALL RECOGNIZE AND ABIDE BY ALL OSHA EXCAVATION SAFETY STANDARDS, INCLUDING THE FLORIDA TRENCH SAFETY ACT (FS 553.60-553.64). ANY MATERIAL, CONSTRUCTION METHODS, OR MATERIAL COST TO COMPLY WITH THESE LAWS SHALL BE INCIDENTAL TO THE CONTRACT.
3. THE CONTRACTOR SHALL OBTAIN FROM THE OWNER COPIES OF ALL AVAILABLE REGULATORY AGENCY PERMITS AND LOCAL AGENCY PERMITS.
4. THE PROJECT SIZE IS OVER 1 ACRES; THEREFORE, THE CONSTRUCTION IS REQUIRED TO COMPLY WITH THE REQUIREMENTS OF THE NATIONAL
POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES) GENERAL PERMIT FOR STORMWATER DISCHARGE FROM SMALL AND LARGE CONSTRUCTION ACTIVITIES. IN ORDER TO MEET NPDES REQUIREMENTS, THE CONTRACTOR IS RESPONSIBLE FOR PREPARING A STORMWATER POLLUTION PREVENTION PLAN (SWPPP), IMPLEMENTING, INSPECTING, MAINTAINING, AND REPORTING ON ALL ELEMENTS OF THE SWPPP, COMPLETING AND SUBMITTING THE REQUIRED NOTICE OF INTENT (NOI) AND NOTICE OF TERMINATION (NOT) FORMS AS THE OPERATOR, AND PAYING ALL ASSOCIATED FEES.
5. THE EROSION AND SEDIMENT CONTROL MEASURES SHOWN ON THE PLANS REPRESENT A MINIMUM REQUIREMENT. THE CONTRACTOR IS RESPONSIBLE FOR DETERMINING ADDITIONAL EROSION AND SEDIMENT CONTROL MEASURES NEEDED IN ORDER TO PREVENT THE TRANSFER OF SEDIMENT FROM THE PROJECT AREA AND PREVENT THE EROSION OF SURFACES DURING CONSTRUCTION, AS NEEDED TO PROTECT ADJACENT PROPERTIES AND WATER
BODIES.
6. IN THE EVENT THAT WATER IS ENCOUNTERED DURING CONSTRUCTION, DEWATERING SHALL BE CONDUCTED. THE CONTRACTOR IS SOLELY RESPONSIBLE FOR THE DESIGN, INSTALLATION, OPERATION, AND SUBSEQUENT REMOVAL OF DEWATERING SYSTEMS AND THEIR SAFETY AND CONFORMITY WITH LOCAL CODES AND REGULATIONS. IF DEWATERING EQUIPMENT NEEDED EXCEEDS ANY OF THE FOLLOWING: 1) 6" PUMP VOLUTE;
2) 100,000 GPD TOTAL 24 HOUR (1 DAY) DEWATERING, AND; 3) 1,000,000 GPD PUMP CAPACITY, THE CONTRACTOR SHALL BE REQUIRED TO PERMIT THE DEWATERING SYSTEM WITH THE ST. JOHNS RIVER WATER MANAGEMENT DISTRICT (SJRWMD). THE ENGINEER AND/OR OWNER SHALL BE NOTIFIED
IMMEDIATELY IF ANY OF THE ABOVE THRESHOLDS ARE EXCEEDED.
7. DEWATERING DISCHARGE FROM THE SITE SHALL COMPLY WITH ALL NPDES GENERAL PERMIT REQUIREMENTS AND STATE WATER QUALITY STANDARDS.
PROVIDE ALL TESTING AND PERMITTING REQUIRED AND COMPLY WITH ALL TREATMENT OR DISPOSAL METHODS REQUIRED TO MEET ALL LOCAL, STATE
AND FEDERAL REQUIREMENTS.
8. UNLESS OTHERWISE DIRECTED BY THE OWNER OR ENGINEER, THE CONTRACTOR IS EXPECTED TO CONTAIN ALL CONSTRUCTION ACTIVITIES WITHIN THE PROPERTY BOUNDARY, AND OTHER AREAS SPECIFICALLY DESIGNATED FOR CONSTRUCTION. AT NO TIME SHALL THE CONTRACTOR DISTURB SURROUNDING PROPERTIES OR TRAVEL ON SURROUNDING PROPERTIES WITHOUT WRITTEN CONSENT FROM THE PROPERTY OWNER. ANY REPAIR OR RECONSTRUCTION OF DAMAGED AREAS IN SURROUNDING PROPERTIES SHALL BE REPAIRED BY THE CONTRACTOR ON AN IMMEDIATE BASIS. ALL COSTS FOR REPAIRS SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR AND NO EXTRA COMPENSATION SHALL BE PROVIDED.
9. UNLESS OTHERWISE NOTED ON THE PLANS, THE CONTRACTOR SHALL USE THE GEOMETRY PROVIDED ON THE CONSTRUCTION PLANS. BENCHMARK INFORMATION SHALL BE PROVIDED TO THE CONTRACTOR BY THE PROJECT SURVEYOR. ANY DISCREPANCIES BETWEEN FIELD MEASUREMENTS AND CONSTRUCTION PLAN INFORMATION SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER IMMEDIATELY.
10.THE ENTIRE PROJECT SITE SHALL BE THOROUGHLY CLEANED AT THE COMPLETION OF THE WORK. CLEAN ALL INSTALLED PIPELINES, STRUCTURES, SIDEWALKS, PAVED AREAS, ACCUMULATED SILT IN PONDS, PLUS ALL ADJACENT AREAS AFFECTED BY CONSTRUCTION, AS DIRECTED BY THE OWNER OR JURISDICTIONAL AGENCY. EQUIPMENT TO CLEAN THESE SURFACES SHALL BE SUBJECT TO APPROVAL BY THE OWNER.
UTILITY GENERAL NOTES
1. THE UTILITY DATA SHOWN ON THESE PLANS WAS LOCATED BY THE RESPECTIVE UTILITY, OR IS BASED ON UTILITY DRAWINGS, MAPS, OR FIELD
RECONNAISSANCE.
2. THE LOCATIONS OF ALL EXISTING UTILITIES SHOWN ON THE PLANS HAVE BEEN DETERMINED FROM THE BEST INFORMATION AVAILABLE AND ARE GIVEN
FOR THE CONVENIENCE OF THE CONTRACTOR. THE ENGINEER ASSUMES NO RESPONSIBILITY FOR THEIR ACCURACY. PRIOR TO THE START OF ANY CONSTRUCTION ACTIVITY, IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO NOTIFY THE VARIOUS UTILITIES AND TO MAKE THE NECESSARY ARRANGEMENTS FOR ANY RELOCATIONS OF THESE UTILITIES WITH THE OWNER OF THE UTILITY. THE CONTRACTOR SHALL EXERCISE CAUTION WHEN CROSSING AN UNDERGROUND UTILITY, WHETHER SHOWN ON THE PLANS OR LOCATED BY THE UTILITY COMPANY. ANY UTILITIES, WHETHER SHOWN ON THESE PLANS OR NOT, THAT INTERFERE WITH THE PROPOSED CONSTRUCTION SHALL BE CLOSELY COORDINATED WITH THE ENGINEER AND THE
RESPECTIVE UTILITY COMPANY FOR RELOCATION OR PROPER INSTRUCTION.
3. A SINGLE POINT UTILITY IDENTIFICATION SERVICE HAS BEEN SET UP FOR EXISTING UTILITIES. THE CONTRACTOR IS TO CONTACT THE SUNSHINE STATE ONE CALL CENTER BY DIALING "811" AT LEAST TWO (2) AND NO MORE THAN FIVE (5) WORKING DAYS PRIOR TO THE SPECIFIC CONSTRUCTION ACTIVITY FOR FIELD LOCATION. NOTE THAT NOT ALL UTILITIES PARTICIPATE IN THIS PROGRAM. THE CONTRACTOR SHOULD CONTACT ALL NON-PARTICIPATING UTILITIES SEPARATELY FOR FIELD LOCATION OF THEIR FACILITIES AT LEAST TWO (2) WORKING DAYS PRIOR TO CONSTRUCTION. PER FLORIDA STATUTE 553.851, THE CONTRACTOR OR EXCAVATOR IS REQUIRED TO NOTIFY THE GAS COMPANY TWO (2) WORKING DAYS PRIOR TO STARTING EXCAVATION.
4. THE FOLLOWING UTILITIES HAVE PREVIOUSLY INDICATED THAT THEY MAY HAVE FACILITIES IN THE VICINITY OF THE CONSTRUCTION AREA:
CITY OF DELAND
ATTN: JIM AILES
386-740-6852
AT&T/ DISTRIBUTION
ATTN: DINO FARRUGGIO
561-683-2729
CHARTER COMMUNICATIONS
ATTN: USIC DISPATCH
OFFICE 800-778-9140
CITY OF DELAND
ATTN: JAMES BAKER
386-626-7258
DUKE ENERGY
ATTN: USIC DISPATCH
800-778-9140
FL PUBLIC UTILITIES
ATTN: RONI (VERONICA) THOMAS
352-459-1589
5. THE CONTRACTOR SHALL KEEP LOCATE TICKETS UP TO DATE AT ALL TIMES.
6. THE CONTRACTOR IS RESPONSIBLE FOR ALL COORDINATION WITH EACH UTILITY AND ALL COSTS ASSOCIATED WITH THE PROTECTION OF EXISTING
FACILITIES DURING CONSTRUCTION. THE CONTRACTOR SHALL ALSO COORDINATE NECESSARY RELOCATIONS OR OTHER CONSTRUCTION RELATED
MATTERS WITH EACH UTILITY.
7. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO MAINTAIN IN SERVICE ALL EXISTING PIPING ENCOUNTERED DURING CONSTRUCTION UNLESS OTHERWISE INDICATED IN THE DRAWINGS. ANY PIPING WHICH CAN BE REMOVED DURING CONSTRUCTION WITHOUT UNDUE INTERRUPTION OF SERVICE MAY BE REMOVED AND REPLACED BY THE CONTRACTOR WITH THE PERMISSION OF THE OWNER AND THE ENGINEER.
8. THE CONTRACTOR SHALL FIELD LOCATE ALL WATER AND SEWER SERVICES AND LATERALS WITHIN THE PROPOSED CONSTRUCTION AREA PRIOR TO CONSTRUCTION AND ADJUST THE PROPOSED CONSTRUCTION AS NEEDED TO ACCOMMODATE THESE EXISTING LINES.
9. TYPICAL DETAILS AND PROPOSED CONSTRUCTION AS SHOWN ILLUSTRATE THE ENGINEER'S INTENT AND ARE NOT PRESENTED AS A SOLUTION TO ALL CONSTRUCTION PROBLEMS ENCOUNTERED IN THE FIELD. THE CONTRACTOR MAY ALTER THE PROPOSED CONSTRUCTION TO SUIT FIELD CONDITIONS, PROVIDED IT COMPLIES WITH THE PROJECT SPECIFICATIONS AND APPROVAL IS RECEIVED FROM THE ENGINEER. WHERE SUCH PROPOSED REVISIONS DEVIATE FROM THE FDEP CONSTRUCTION PERMIT, THEN SUCH REVISIONS WILL ALSO REQUIRE APPROVAL FROM FDEP.
10.FOR EACH RESPECTIVE PIPELINE CONSTRUCTION REQUIRED, THE CONTRACTOR SHALL FIELD VERIFY THE LOCATION, DEPTH, AND ALIGNMENT OF ALL EXISTING PIPES, CABLES, ETC. TO BE CROSSED OR CONNECTED TO. IF THE CONTRACTOR DEEMS NECESSARY (A) A CHANGE IN ALIGNMENT OR DEPTH, OR THE NEED FOR ADDITIONAL FITTINGS, BENDS, OR COUPLINGS, WHICH REPRESENT A DEPARTURE FROM THE CONTRACT DRAWING, OR (B) A NEED FOR RELOCATION OF EXISTING UTILITIES, THEN DETAILS OF SUCH DEPARTURES, RELOCATIONS, OR ADDITIONAL FITTINGS, INCLUDING CHANGES IN RELATED PORTIONS OF THE PROJECT AND THE REASONS THEREFORE, SHALL BE SUBMITTED WITH SHOP DRAWINGS. APPROVED DEPARTURES FOR
THE CONTRACTOR'S CONVENIENCE SHALL BE MADE AT NO ADDITIONAL COST TO THE OWNER.
11.THE CONTRACTOR SHALL PROVIDE AT HIS OWN EXPENSE ALL NECESSARY TEST PUMPING EQUIPMENT, WATER, WATER METERS, PRESSURE GAUGES, AND OTHER EQUIPMENT, MATERIAL AND FACILITIES REQUIRED FOR ALL HYDROSTATIC, LEAKAGE, AND PRESSURE TESTING. THE CONTRACTOR SHALL CONTACT THE ENGINEER AND THE OWNER IN WRITTEN FORM, FORTY-EIGHT (48) HOURS IN ADVANCE OF PROPOSED TESTING. THE CONTRACTOR SHALL
PERFORM SATISFACTORY PRETESTING PRIOR TO NOTIFICATION.
TRAFFIC CONTROL
1. THE CONTRACTOR IS RESPONSIBLE FOR PROVIDING A MAINTENANCE OF TRAFFIC (M.O.T.) PLAN PRIOR TO CONSTRUCTION. THE M.O.T. PLAN SHALL
SHOW ALL PROPOSED TRAFFIC CONTROL SIGNS, PAVEMENT MARKINGS, AND BARRICADES, AND SHALL DETAIL ALL PROPOSED CONSTRUCTION
SEQUENCING. THE M.O.T. PLAN SHALL BE APPROVED BY THE CITY PRIOR TO CONSTRUCTION.
2. ALL CONSTRUCTION SIGNING AND MARKINGS SHALL BE INSTALLED PRIOR TO CONSTRUCTION AND MAINTAINED DURING CONSTRUCTION IN ACCORDANCE WITH FDOT INDEX NO. 600 AND THE MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES (MUTCD). THE PLACEMENT OF THE SIGNING AND
MARKINGS SHALL BE APPROVED IN THE FIELD BY THE ENGINEER PRIOR TO CONSTRUCTION.
3. INSPECT TRAFFIC CONTROL DEVICES ON A DAILY BASIS TO ENSURE PLACEMENT OF BARRICADES AND FUNCTION OF LIGHTS IS MAINTAINED
THROUGHOUT CONSTRUCTION.
4. WET UNSTABILIZED AREAS AS NECESSARY TO CONTROL DUST.
5. ADJUST TRAFFIC CONTROL DEVICES AS REQUIRED UNDER EMERGENCY CONDITIONS.
6. WHEN WORK OCCURS WITHIN 15-FT OF ACTIVE ROAD TRAVEL LANES BUT NO CLOSER THAN 2-FT FROM THE EDGE OF PAVEMENT, SIGNAGE AND
WARNING DEVICES ARE TO BE INSTALLED IN ACCORDANCE WITH FDOT INDEX NO. 600 AND 602.
7. TYPE I OR TYPE II BARRICADES AT 20-FT CENTERS SHALL BE PLACED AND MAINTAINED ALONG THE EDGE OF THE ROAD WHEREVER DROP-OFFS OR
OTHER HAZARDS EXIST AND TO BLOCK ENTRANCE INTO COMPLETED OR PARTIALLY COMPLETED PAVEMENTS UNTIL SUCH PAVEMENTS ARE OPEN TO
PUBLIC USE.
UTILITY SEPARATION REQUIREMENTS
1. THE HORIZONTAL SEPARATION BETWEEN WATER MAINS AND SANITARY SEWER, STORM SEWER, WASTEWATER FORCE MAINS, STORMWATER FORCE MAINS, RECLAIMED WATER MAINS AND ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEMS SHALL BE IN
ACCORDANCE WITH THE FOLLOWING:
A. THE OUTSIDE OF WATER MAINS SHALL BE A MINIMUM OF THREE FEET FROM THE OUTSIDE OF ANY EXISTING OR PROPOSED STORM SEWER, STORMWATER FORCE MAIN, VACUUM TYPE SANITARY SEWER AND RECLAIMED WATER MAIN.
B. THE OUTSIDE OF WATER MAINS SHALL BE A MINIMUM OF SIX FEET FROM THE OUTSIDE OF ANY EXISTING OR PROPOSED GRAVITY SANITARY SEWER AND WASTEWATER FORCE MAIN. THE MINIMUM HORIZONTAL SEPARATION DISTANCE BETWEEN THE OUTSIDE OF WATER MAINS AND THE OUTSIDE OF GRAVITY SANITARY SEWERS CAN BE REDUCED TO THREE FEET WHERE THE BOTTOM OF
THE WATER MAIN IS AT LEAST SIX INCHES ABOVE THE TOP OF THE SEWER.
C. THE OUTSIDE OF WATER MAINS SHALL BE A MINIMUM OF TEN FEET FROM ALL PARTS OF ANY EXISTING OR PROPOSED ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM SUCH AS SEPTIC TANKS, DRAINFIELDS, AND GREASE TRAPS. ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEMS DO NOT INCLUDE PACKAGE SEWAGE TREATMENT FACILITIES AND PUBLIC WASTEWATER
TREATMENT FACILITIES.
2. THE VERTICAL SEPARATION BETWEEN WATER MAINS AND SANITARY AND STORM SEWER, WASTEWATER OR STORMWATER FORCE
MAINS, AND RECLAIMED WATER MAINS SHALL BE IN ACCORDANCE WITH THE FOLLOWING:
A. WHEREVER POSSIBLE, WATER MAINS SHALL CROSS OVER EXISTING OR PROPOSED GRAVITY SANITARY SEWER, VACUUM TYPE SANITARY SEWER, AND STORM SEWER, SO THE OUTSIDE OF THE WATER MAIN IS AT LEAST SIX INCHES ABOVE THE OUTSIDE OF THE SEWER. WHERE IT IS NOT POSSIBLE FOR THE WATER MAIN TO CROSS OVER EXISTING OR PROPOSED GRAVITY SANITARY SEWER, VACUUM TYPE SANITARY SEWER, AND STORM SEWER, THEN THE WATER MAIN CAN CROSS UNDER THESE TYPES OF PIPELINE SYSTEMS PROVIDED THE OUTSIDE OF THE WATER MAIN IS AT LEAST 12 INCHES BELOW THE OUTSIDE OF THE PIPELINE.
AT THE CROSSING, THE PROPOSED PIPE JOINTS SHALL BE ARRANGED SO THAT ALL WATER MAIN JOINTS ARE AT LEAST THREE FEET FROM VACUUM TYPE SANITARY SEWER OR STORM SEWER JOINTS, AND AT LEAST SIX FEET FROM GRAVITY SANITARY
SEWER JOINTS.
B. WHEREVER POSSIBLE, WATER MAINS SHALL CROSS OVER EXISTING OR PROPOSED RECLAIMED WATER MAINS, WASTEWATER FORCE MAINS AND STORMWATER FORCE MAINS. WHETHER THE WATER MAIN CROSSES OVER OR UNDER THESE TYPES OF PIPELINE SYSTEMS, THE OUTSIDE OF THE WATER MAIN SHALL BE AT LEAST 12 INCHES FROM THE OUTSIDE OF THE EXISTING OR PROPOSED RECLAIMED WATER MAIN, WASTEWATER FORCE MAIN AND STORMWATER FORCE MAIN. AT THE CROSSING, THE PROPOSED PIPE JOINTS SHALL BE ARRANGED SO THAT ALL WATER MAIN JOINTS ARE AT LEAST THREE FEET FROM RECLAIMED WATER MAIN JOINTS AND STORMWATER FORCE MAIN JOINTS, AND AT LEAST SIX FEET FROM THE JOINTS OF WASTEWATER FORCE
MAINS.
3. NO WATER MAIN SHALL PASS THROUGH OR COME IN CONTACT WITH ANY PART OF A SANITARY SEWER MANHOLE.
4. NEW OR RELOCATED FIRE HYDRANTS SHALL BE LOCATED SUCH THAT THE UNDERGROUND DRAIN (WEEP HOLE) IS AT LEAST:
A. THREE FEET FROM ANY EXISTING OR PROPOSED STORM SEWER, STORMWATER FORCE MAIN, RECLAIMED WATER MAIN, OR
VACUUM TYPE SANITARY SEWER.
B. SIX FEET FROM ANY EXISTING OR PROPOSED GRAVITY SANITARY SEWER AND WASTEWATER FORCE MAIN.
C. TEN FEET FROM ANY ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM SUCH AS SEPTIC TANKS, DRAINFIELDS, AND GREASE
TRAPS. ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEMS DO NOT INCLUDE PACKAGE SEWAGE TREATMENT FACILITIES AND
PUBLIC WASTEWATER TREATMENT FACILITIES.
5. THE FOLLOWING ARE ACCEPTABLE ALTERNATIVE CONSTRUCTION VARIANCES WHERE IT IS NOT POSSIBLE TO MEET THE SEPARATION REQUIREMENTS, AND ARE ONLY TO BE IMPLEMENTED UPON RECEIPT OF EXPRESSED WRITTEN CONSENT FROM THE ENGINEER AND APPROVAL FROM FDEP ON A CASE BY CASE BASIS. IMPLEMENTATION OF THESE MEASURES WITHOUT THE EXPRESSED WRITTEN CONSENT OF THE ENGINEER AND APPROVAL FROM FDEP COULD RESULT IN THE REQUIREMENT THAT THE INSTALLED UNAPPROVED
MEASURES BE REMOVED AND REPLACED AT NO COST.
A. WHERE A WATER MAIN IS LESS THAN THE REQUIRED MINIMUM HORIZONTAL DISTANCE FROM ANOTHER PIPELINE OR WHERE A WATER MAIN CROSSES ANOTHER PIPELINE AND JOINTS IN THE WATER MAIN ARE LESS THAN THE MINIMUM REQUIRED DISTANCE
BETWEEN THE JOINTS IN THE OTHER PIPELINE:
1) USE OF PRESSURE RATED PIPE CONFORMING TO AWWA STANDARDS FOR A GRAVITY OR VACUUM TYPE PIPELINE.
2) USE OF WELDED, FUSED, OR OTHERWISE RESTRAINED JOINTS FOR EITHER PIPELINE.
3) USE OF WATERTIGHT CASING PIPE OR CONCRETE ENCASEMENT AT LEAST FOUR INCHES THICK FOR EITHER PIPE.
B. WHERE A WATER MAIN IS LESS THAN THREE FEET HORIZONTALLY FROM ANOTHER PIPELINE OR WHERE A WATER MAIN CROSSES
ANOTHER PIPELINE LESS THAN THE REQUIRED MINIMUM SEPARATION:
1) USE OF PIPE OR CASING PIPE, HAVING HIGH IMPACT STRENGTH (AT LEAST EQUAL TO 0.25 INCH THICK DUCTILE IRON PIPE), OR CONCRETE ENCASEMENT AT LEAST FOUR INCHES THICK FOR THE WATER MAIN AND FOR THE OTHER PIPELINE IF THE
OTHER PIPELINE COVEYS WASTEWATER OR RECLAIMED WATER.
STORM NOTES
1. ALL STORM SEWER PIPE SHALL BE REINFORCED CONCRETE PIPE (RCP) UNLESS OTHERWISE INDICATED ON THE DRAWINGS. ROUND
CONCRETE PIPE SHALL COMPLY WITH ASTM C76. ELLIPTICAL CONCRETE PIPE SHALL COMPLY WITH ASTM C507. PIPE JOINTS SHALL COMPLY WITH ASTM C443 AND FDOT SPECIFICATION SECTION 430, AND RUBBER GASKETS SHALL COMPLY WITH FDOT SPECIFICATION SECTION 942. MINIMUM COVER OVER THE PIPE, INCLUDING COVER OVER THE BELL OF THE PIPE WHERE APPLICABLE, SHALL BE 30
INCHES.
2. RCP PIPE SHALL NOT BE SHIPPED FROM MANUFACTURER UNTIL THE COMPRESSIVE STRENGTH OF THE PIPE HAS REACHED 4000 PSI AND A MINIMUM OF 5 DAYS HAVE PASSED SINCE THE MANUFACTURING OR REPAIR OF THE PIPE HAS BEEN COMPLETED.
3. CORRUGATED POLYETHYLENE PIPE AND FITTINGS 4 INCH THROUGH 10 INCH DIAMETER SHALL COMPLY WITH AASHTO M252, TYPE S.
PIPE 12 INCH THROUGH 48 INCH DIAMETER SHALL COMPLY WITH AASHTO M294, TYPE S, AND ASTM F2306. PIPE 54 INCH THROUGH 60 INCH DIAMETER SHALL COMPLY WITH FDOT SPECIFICATION SECTION 948 (CLASS II PIPE) AND SHALL COMPLY WITH AASHTO M294.
VIRGIN MATERIAL FOR THE PRODUCTION OF PIPE AND FITTINGS SHALL BE HIGH DENSITY POLYETHYLENE CONFORMING TO THE MINIMUM REQUIREMENTS OF CELL CLASSIFICATION 424420C FOR 4-INCH THROUGH 10-INCH DIAMETERS AND 435400C FOR 12-INCH THROUGH 60-INCH DIAMETERS PER ASTM D3350. THE 12-INCH THROUGH 60-INCH VIRGIN PIPE MATERIAL SHALL COMPLY WITH THE NOTCHED CONSTANT LIGAMENT-STRESS (NCLS) TEST AS SPECIFIED IN ASTM F2306. BELL JOINTS FOR 4 INCH THROUGH 10 INCH DIAMETER PIPE SHALL BE PUSH-ON SLEEVE. BELL JOINTS FOR 12 INCH THROUGH 60 INCH DIAMETER PIPE SHALL BE INTEGRALLY FORMED ON PIPE. PIPE JOINTS SHALL BE WATERTIGHT PER ASTM D3212. GASKETS SHALL BE INSTALLED BY PIPE MANUFACTURER AND
SHALL COMPLY WITH ASTM F477.
4. UNDERDRAIN PIPE SHALL BE PERFORATED POLYVINYL CHLORIDE PIPE IN ACCORDANCE WITH ASTM F758. FILTER FABRIC UNDERDRAIN
SOCK SHALL BE TYPE D-3 IN ACCORDANCE WITH FDOT INDEX NO. 199.
5. ALL PIPE JOINTS SHALL BE WRAPPED WITH FILTER FABRIC. FILTER FABRIC SHALL BE IN ACCORDANCE WITH FDOT INDEX199, TYPE D-3, A.O.S. 70-100. INSTALL IN ACCORDANCE WITH FDOT INDEX NO. 280. PROVIDE MINIMUM 12" OVERLAP.
6. INSTALL POLYETHYLENE PIPE IN ACCORDANCE WITH ASTM D2321. BACKFILL AND COMPACT EVENLY ON EACH SIDE TO PREVENT DISPLACEMENT. MINIMUM COVER OVER POLYETHYLENE PIPE SHALL BE AS FOLLOWS: A) PIPE UNDER FLEXIBLE PAVEMENT, RIGID PAVEMENT, OR UNPAVED AREAS WHERE BEDDING IS SUITABLE SOILS AS DEFINED IN THE GENERAL NOTES: MINIMUM COVER SHALL BE 36 INCHES OR ONE PIPE DIAMETER, WHICHEVER IS GREATER; B) PIPE UNDER FLEXIBLE PAVEMENT, RIGID PAVEMENT, OR UNPAVED AREAS WHERE BEDDING IS MANUFACTURED AGGREGATES CLASS 1A OR 1B AS DEFINED IN ASTM D2321: MINIMUM COVER SHALL BE 30
INCHES OR ONE PIPE DIAMETER, WHICHEVER IS GREATER.
7. INSTALL UNDERDRAINS IN ACCORDANCE WITH FDOT SPECIFICATION SECTION 440. INSTALL CLEANOUTS AS SHOWN ON THE DRAWINGS.
8. PRIOR TO INSPECTIONS AND TESTING, CLEAN ALL INSTALLED LINES AND STRUCTURES.
9. ALL STORM PIPE SHALL BE SUBJECTED TO LEAKAGE TESTING. WHEN THE GROUND WATER LEVEL IS ABOVE THE TOP OF THE PIPE, AN
INFILTRATION TEST SHALL BE PERFORMED BY SEALING OFF A LENGTH OF PIPE AND MEASURING THE DEPTH OF FLOW OVER A MEASURING WEIR, OR BY PUMPING THE INFILTRATED WATER INTO CONTAINERS FOR MEASUREMENT. TESTS SHALL BE CONDUCTED FOR A MINIMUM OF FOUR HOURS. INFILTRATION LEAKAGE SHALL NOT EXCEED 150 GALLONS PER 24 HOURS, PER INCH DIAMETER, PER MILE OF PIPE. WHEN THE GROUND WATER LEVEL IS BELOW THE TOP OF THE PIPE, THE PIPE SHALL BE TESTED FOR LEAKAGE BY EXFILTRATION. EXFILTRATION LEAKAGE TEST SHALL CONSIST OF ISOLATING THE PARTICULAR SECTION, FILLING WITH WATER TO A POINT 4 FEET ABOVE THE TOP OF THE PIPE AT THE UPPER MANHOLE OR INLET, AND ALLOWING IT TO STAND NOT LESS THAN FOUR HOURS. THE SECTION SHALL THEN BE REFILLED WITH WATER UP TO THE ORIGINAL LEVEL AND AFTER TWO HOURS THE DROP IN WATER SURFACE SHALL BE MEASURED. THE COMPUTED LEAKAGE SHALL NOT EXCEED 150 GALLONS PER INCH DIAMETER, PER 24
HOURS, PER MILE OF PIPE.
AutoCAD SHX Text
LOCATION OF PUBLIC WATER SYSTEM MAINS IN ACCORDANCE WITH F.A.C. RULE 62-555.314
AutoCAD SHX Text Reclaimed Water (4)
AutoCAD SHX Text Sanitary Sewer Force Main, AutoCAD SHX Text Gravity Sewer
AutoCAD SHX Text Sanitary Sewer, AutoCAD SHX Text Vacuum Sanitary Sewer
AutoCAD SHX Text & Disposal System(4)
AutoCAD SHX Text On-Site Sewage Treatment
AutoCAD SHX Text Reclaimed Water (2)
AutoCAD SHX Text Storm Sewer
AutoCAD SHX Text Stormwater Force Main, AutoCAD SHX Text (Full Joint Centered)
AutoCAD SHX Text Joint Spacing @ Crossing
AutoCAD SHX Text Crossings (1)
AutoCAD SHX Text Horizontal Separation
AutoCAD SHX Text Other pipe
AutoCAD SHX Text
WATER MAIN
AutoCAD SHX Text 3 ft. minimum
AutoCAD SHX Text 10 ft. preferred
AutoCAD SHX Text 3 ft. minimum
AutoCAD SHX Text 3 ft. minimum (3)
AutoCAD SHX Text 10 ft. preferred
AutoCAD SHX Text
WATER MAIN
AutoCAD SHX Text 12 inches is the minimum
AutoCAD SHX Text except for storm sewer,then
AutoCAD SHX Text 12 inches is preferred
AutoCAD SHX Text 6 inches is the minimum and
AutoCAD SHX Text
(1) Water Main Should Cross Above other pipe. When Water Main Must Be Below Other Pipe,the Minimum Separation is 12" Inches.
AutoCAD SHX Text
(2) Reclaimed Water Regulated Under Part III of chapter 62-610, F.A.C.
AutoCAD SHX Text
(3) 3 ft. for Gravity Sanitary sewer where the Bottom of the Water Main is laid at least 6 inches above the top of gravity sanitary sewer.
AutoCAD SHX Text
(4) Reclaimed water not regulated under part III
AutoCAD SHX Text
WATER MAIN
AutoCAD SHX Text
WATER MAIN
AutoCAD SHX Text 10 ft minimum
AutoCAD SHX Text
AutoCAD SHX Text Alternate 3' ft. minimum
AutoCAD SHX Text
WATER MAIN
AutoCAD SHX Text
WATER MAIN
AutoCAD SHX Text Alternate 3' ft. minimum
AutoCAD SHX Text 6 inches minimum
AutoCAD SHX Text 12 inches preferred
AutoCAD SHX Text
WATER MAIN
AutoCAD SHX Text
WATER MAIN
AutoCAD SHX Text Alternate 6' ft. minimum
AutoCAD SHX Text 6 inches is the minimum and
AutoCAD SHX Text 12 inches is preferred
AutoCAD SHX Text except for gravity sewer,then
AutoCAD SHX Text 12 inches is the minimum
AutoCAD SHX Text
WATER MAIN
AutoCAD SHX Text
AutoCAD SHX Text J:\D0942\Civil\DWG\_Current_Plan_Set\D0942 - GENERAL NOTES.dwg, 1/2/2025 5:07:38 PM, Amir Khorramian, _cph - Civil And Landscape.stb, 1/2/2025 5:07:38 PM, Amir Khorramian, _cph - Civil And Landscape.stb1/2/2025 5:07:38 PM, Amir Khorramian, _cph - Civil And Landscape.stb, Amir Khorramian, _cph - Civil And Landscape.stbAmir Khorramian, _cph - Civil And Landscape.stb, _cph - Civil And Landscape.stb_cph - Civil And Landscape.stb
1234567
C 2025
Checked By:
Drawn By:
Approved By:
Job No.:
Date:
Field Crew:
3/18/2024
D0942
T. Galloway
P. Katrek M. Nelson
M. Reigard
Sheet No.
THIS SURVEY IS NOT VALID
WITHOUT SURVEY SHEETS
1 THROUGH 3 OF 3.
V0.1
VICINITY MAP
SITE
N
TO
PO
G R
A
PH
IC
S
U R
VE
Y
SE
C
TI
O
N
6-
TO
W N
SH
IP
SO
U
TH
-R
A N
G E
E
A
ST
VO
LU
SI
A
C O
U N
TY
, F
LO
R
ID
A
SP
EC
M A
R
TI
N S
TA
D
IU
M
E
EU
C
LI
D A
VE
N
U E
C
IT
Y O
F D
EL
A
N D
Topographic Survey Area:
CPH, LLC
A Full Service A & E Firm
Plans Prepared By:
State of Florida License:
Surveyor No. LB7143
500 West Fulton Street Sanford, FL 32771 Ph: 407.322.6841
Survey Sheet 1
B y
R ev is io n D at e
N o.
Abbreviation Legend:
Sign Legend:
Symbol Legend:
Line Legend:
TOPOGRAPHIC SURVEY
FOR
AT
SPEC MARTIN STADIUM
290 E EUCLID AVENUE
LYING IN
SECTION 16-TOWNSHIP 17 SOUTH-RANGE 30 EAST
CITY OF DELAND, VOLUSIA COUNTY, FLORIDA
CITY OF DELAND
SITE
Survey Notes:
Index of Survey Sheets
Surveyor's Certification:
www.cphcorp.com Building Better
Communities Together
SITE BENCHMARK #502
SITE BENCHMARK #505
SITE BENCHMARK #506
SITE BENCHMARK #501
SITE BENCHMARK #516
SITE BENCHMARK #504
SITE BENCHMARK #522
E EUCLID AVENUE
S A
LA
B
A M
A A
VE
N
U E
1234567
C 2024
Checked By:
Drawn By:
Approved By:
Job No.:
Date:
Field Crew:
3/18/2024
D0942
T. Galloway
P. Katrek M. Nelson
M. Reigard
Sheet No.
V1.1
TO
PO
G R
A
PH
IC
S
U R
VE
Y
SE
C
TI
O
N
6-
TO
W N
SH
IP
SO
U
TH
-R
A N
G E
E
A
ST
VO
LU
SI
A
C O
U N
TY
, F
LO
R
ID
A
SP
EC
M A
R
TI
N S
TA
D
IU
M
E
EU
C
LI
D A
VE
N
U E
C
IT
Y O
F D
EL
A
N D
N
020 20 40
Scale: 1" = 20'
CPH, LLC
A Full Service A & E Firm
Plans Prepared By:
State of Florida License:
Surveyor No. LB7143
500 West Fulton Street Sanford, FL 32771 Ph: 407.322.6841 www.cphcorp.com Building Better
Communities Together
THIS SURVEY IS NOT VALID
WITHOUT SURVEY SHEETS
1 THROUGH 3 OF 3.
Survey Sheet 2
B y
R ev is io n D at e
N o.
MATCH LINE "A" - SEE SURVEY SHEET 3 0F 3
SITE BENCHMARK #301
SITE BENCHMARK #507
E HUBBARD AVENUE
S A
LA
B
A M
A A
VE
N
U E
SITE BENCHMARK #510
C O
U N
TY
R
O A
D
1234567
C 2024
Checked By:
Drawn By:
Approved By:
Job No.:
Date:
Field Crew:
3/18/2024
D0942
T. Galloway
P. Katrek M. Nelson
M. Reigard
Sheet No.
V1.2
TO
PO
G R
A
PH
IC
S
U R
VE
Y
SE
C
TI
O
N
6-
TO
W N
SH
IP
SO
U
TH
-R
A N
G E
E
A
ST
VO
LU
SI
A
C O
U N
TY
, F
LO
R
ID
A
SP
EC
M A
R
TI
N S
TA
D
IU
M
E
EU
C
LI
D A
VE
N
U E
C
IT
Y O
F D
EL
A
N D
N
020 20 40
Scale: 1" = 20'
CPH, LLC
A Full Service A & E Firm
Plans Prepared By:
State of Florida License:
Surveyor No. LB7143
500 West Fulton Street Sanford, FL 32771 Ph: 407.322.6841 www.cphcorp.com Building Better
Communities Together
THIS SURVEY IS NOT VALID
WITHOUT SURVEY SHEETS
1 THROUGH 3 OF 3.
Survey Sheet 3
B y
R ev is io n D at e
N o.
MATCH LINE "A" - SEE SURVEY SHEET 2 OF 3
M A
TC
H
L
IN
E "B
- S
EE
B
EL
O
W
M A
TC
H
L
IN
E "B
- S
EE
A
B O
VE
SITE BENCHMARK #506
SITE BENCHMARK #501
SITE BENCHMARK #516
SITE BENCHMARK #504
SITE BENCHMARK #522
E EUCLID AVENUE
S A
LA
B
A M
A A
VE
N
U E
EXISTING FENCE
TO BE REMOVED
EXISTING FENCE
TO BE REMOVED
CONTRACTOR TO NEATLY SAWCUT AT
NEAREST EXISTING CONCRETE JOINT
AND REMOVE PAVEMENT AS SHOWN
NOTE: PORTIONS OF THE EXISTING STORM SEWER
SYSTEM WERE NOT SURVEYED AND THE LOCATION
SHOWN IS APPROXIMATED FROM SEWER TV INSPECTION.
500 West Fulton Street Sanford, FL 32771 Ph: 407.322.6841
D at e N o.
R ev is io n www.cphcorp.com
123456
C 2025
THIS SHEET NOT VALID FOR
CONSTRUCTION WITHOUT
COMPLETE SET OF PLANS.
Sheet No.
Drawn:
Designed:
Checked:
Job No.:
Date:
SP
EC
M A
R
TI
N M
EM
O
R
IA
L
ST
A D
IU
M
0.
E . E uc lid
A ve
D eL an d, F lo rid a
D0942
Building Better Communities Together
CPH CONSULTING ,LLC
A Full Service A &E Firm
Plans Prepared By:
C1.1
D
EM
O
LI
TI
O
N P
LA
N
J. DYMEK
K. BERLINSKY
L. WRAY
09/03/2024
H O
W
AR
D L
. W R
AY
F.
L.
P
.E . N
O . 5
/0
4/
PE
R
C
IT
Y C
O M
M
EN
TS
/1
5/
PE
R
C
IT
Y C
O M
M
EN
TS
MATCH LINE A - SEE MATCH LINE B BELOW
HOWARD L. WRAY, STATE OF FLORIDA,
PROFESSIONAL ENGINEER, LICENSE NO. 55557
THIS ITEM HAS BEEN DIGITALLY SIGNED AND
SEALED BY HOWARD L. WRAY ON THE DATE
INDICATED HERE. PRINTED COPIES OF THIS
DOCUMENT ARE NOT CONSIDERED SIGNED
AND SEALED AND THE SIGNATURE MUST BE
VERIFIED ON ANY ELECTRONIC COPIES.1
www.sunshine811.com
DEMO ASPHALT, CONCRETE, & PAVERS
LEGEND
EXISTING FENCE TO BE REMOVED
LIMITS OF PAVEMENT SAWCUT AND REMOVAL
Graphic Scale in Feet
20 20 40 N
AutoCAD SHX Text 51.9'
AutoCAD SHX Text 12.8'
AutoCAD SHX Text 10.6'
AutoCAD SHX Text 10.7'
AutoCAD SHX Text 30.8'
AutoCAD SHX Text 10.7'
AutoCAD SHX Text 10.7'
AutoCAD SHX Text 12.8'
AutoCAD SHX Text 40.5'
AutoCAD SHX Text 20.1'
AutoCAD SHX Text 47.1'
AutoCAD SHX Text 20.4'
AutoCAD SHX Text 6.6'
AutoCAD SHX Text 7.0'
AutoCAD SHX Text 20.4'
AutoCAD SHX Text 47.1'
AutoCAD SHX Text 20.1'
AutoCAD SHX Text 40.1'
AutoCAD SHX Text 7.5'
AutoCAD SHX Text 15.0'
AutoCAD SHX Text 7.5'
AutoCAD SHX Text 5.9'
AutoCAD SHX Text 16.7'
AutoCAD SHX Text 9.0'
AutoCAD SHX Text 4.1'
AutoCAD SHX Text 9.5'
AutoCAD SHX Text 41.5'
AutoCAD SHX Text 56.3'
AutoCAD SHX Text
OVERHANG
AutoCAD SHX Text FLAT GRATE INLET TOP GRATE ELEV = 37.93 W INV ELEV = 36.58 (CVS) BOTTOM ELEV = 36.03
AutoCAD SHX Text FLAT GRATE INLET TOP GRATE ELEV = 37.93 W INV ELEV = 36.13 (CVS) BOTTOM ELEV = 35.60
AutoCAD SHX Text FLAT GRATE INLET TOP GRATE ELEV = 37.95 W INV ELEV = 36.20 (CVS) BOTTOM ELEV = 35.57
AutoCAD SHX Text FLAT GRATE INLET TOP GRATE ELEV = 37.95 W INV ELEV = 36.41 (CVS) BOTTOM ELEV = 35.80
AutoCAD SHX Text FLAT GRATE INLET TOP GRATE ELEV = 38.17 N INV ELEV = 36.63 (CVS RCP) SE INV ELEV = 36.52 (6" CLAY)
AutoCAD SHX Text FLAT GRATE INLET TOP GRATE ELEV = 38.26 N INV ELEV = 36.63 (CVS RCP) SW INV ELEV = 36.58 (CVS CLAY)
AutoCAD SHX Text FLAT GRATE INLET TOP GRATE ELEV = 38.04 E INV ELEV = 36.13 (CVS) BOTTOM ELEV = 35.66
AutoCAD SHX Text FLAT GRATE INLET TOP GRATE ELEV = 38.05 E INV ELEV = 35.70 (CVS) BOTTOM ELEV = 35.05
AutoCAD SHX Text FLAT GRATE INLET TOP GRATE ELEV = 38.04 E INV ELEV = 36.04 (CVS) BOTTOM ELEV = 35.51
AutoCAD SHX Text FLAT GRATE INLET TOP GRATE ELEV = 38.05 E INV ELEV = 36.05 (CVS) BOTTOM ELEV = 35.66
AutoCAD SHX Text FLAT GRATE INLET TOP GRATE ELEV = 38.05 E INV ELEV = 36.27 (CVS) BOTTOM ELEV = 35.84
AutoCAD SHX Text FLAT GRATE INLET TOP GRATE ELEV = 44.80 S INV ELEV = 38.68 (18" CPP) BOTTOM ELEV = 38.4±
AutoCAD SHX Text FLAT GRATE INLET TOP GRATE ELEV = 39.24 N INV ELEV = 34.80 (18" CPP) E INV ELEV = 35.52 (8" CPP) SE INV ELEV = 33.84 (24" CPP) BOTTOM ELEV = 33.4±
AutoCAD SHX Text FLAT GRATE INLET TOP GRATE ELEV = 51.52 E INV ELEV = 48.36 (15"CMP) SW INV ELEV = 47.58 (36" CMP) BOTTOM ELEV = 47.5±
AutoCAD SHX Text FLAT GRATE INLET TOP GRATE ELEV = 50.86 E INV ELEV = 48.48 (8" PVC) S INV ELEV = 48.54 (4" PVC) W INV ELEV = 48.48 (15" CMP) BOTTOM ELEV = 48.4±
AutoCAD SHX Text FLAT GRATE INLET TOP GRATE ELEV = 50.67 S INV ELEV = 48.92 (4 "PVC) W INV ELEV = 48.01 (8" PVC) BOTTOM ELEV = 47.8±
AutoCAD SHX Text
FLAT GRATE INLET TOP GRATE ELEV = 43.61 INACCESSIBLE
AutoCAD SHX Text
STORM SEWER MANHOLE TOP RIM ELEV = 43.75 INACCESSIBLE
AutoCAD SHX Text
STORM SEWER MANHOLE TOP RIM ELEV = 44.32 INACCESSIBLE
J:\D0942\Civil\DWG\_Current_Plan_Set\D0942 - DEMO.dwg, 1/2/2025 5:07:55 PM, Amir Khorramian, , 1/2/2025 5:07:55 PM, Amir Khorramian, 1/2/2025 5:07:55 PM, Amir Khorramian, , Amir Khorramian, Amir Khorramian, , E HUBBARD AVENUE
S A
LA
B
A M
A A
VE
N
U E
EXISTING FENCE
TO BE REMOVED EXISTING FENCE
TO BE REMOVED
CONTRACTOR TO NEATLY SAWCUT AT
NEAREST EXISTING CONCRETE JOINT
AND REMOVE PAVEMENT AS SHOWN
UNDERGROUND UTILITIES ARE ANTICIPATED IN THIS AREA,
BUT HAVE NOT BEEN LOCATED BY SURVEY. CONTRACTORS
TO EXERCISE CAUTION AND FIELD VERIFY UNDERGROUND
UTILITIES NEAR THE AC UNIT.
CONTRACTOR TO NEATLY SAWCUT AT
NEAREST EXISTING CONCRETE JOINT
AND REMOVE PAVEMENT AS SHOWN
ADA MAT TO BE DEMOLISHED
MATCH LINE B - SEE MATCH LINE A ABOVE
500 West Fulton Street Sanford, FL 32771 Ph: 407.322.6841
D at e N o.
R ev is io n www.cphcorp.com
123456
C 2025
THIS SHEET NOT VALID FOR
CONSTRUCTION WITHOUT
COMPLETE SET OF PLANS.
Sheet No.
Drawn:
Designed:
Checked:
Job No.:
Date:
SP
EC
M A
R
TI
N M
EM
O
R
IA
L
ST
A D
IU
M
0.
E . E uc lid
A ve
D eL an d, F lo rid a
D0942
Building Better Communities Together
CPH CONSULTING ,LLC
A Full Service A &E Firm
Plans Prepared By:
C1.2
D
EM
O
LI
TI
O
N P
LA
N
J. DYMEK
K. BERLINSKY
L. WRAY
09/03/2024
H O
W
AR
D L
. W R
AY
F.
L.
P
.E . N
O . 5
/0
4/
PE
R
C
IT
Y C
O M
M
EN
TS
/1
5/
PE
R
C
IT
Y C
O M
M
EN
TS
HOWARD L. WRAY, STATE OF FLORIDA,
PROFESSIONAL ENGINEER, LICENSE NO. 55557
THIS ITEM HAS BEEN DIGITALLY SIGNED AND
SEALED BY HOWARD L. WRAY ON THE DATE
INDICATED HERE. PRINTED COPIES OF THIS
DOCUMENT ARE NOT CONSIDERED SIGNED
AND SEALED AND THE SIGNATURE MUST BE
VERIFIED ON ANY ELECTRONIC COPIES.
www.sunshine811.com
DEMO ASPHALT, CONCRETE, & PAVERS
LEGEND
EXISTING FENCE TO BE REMOVED
LIMITS OF PAVEMENT SAWCUT AND REMOVAL
Graphic Scale in Feet
20 20 40 N
AutoCAD SHX Text 40.1'
AutoCAD SHX Text 23.2'
AutoCAD SHX Text 12.9'
AutoCAD SHX Text 15.0'
AutoCAD SHX Text 60.4'
AutoCAD SHX Text 45.5'
AutoCAD SHX Text 47.0'
AutoCAD SHX Text 20.8'
AutoCAD SHX Text 41.4'
AutoCAD SHX Text 15.5'
AutoCAD SHX Text 15.1'
AutoCAD SHX Text 21.7'
AutoCAD SHX Text 3.0'
AutoCAD SHX Text 26.9'
AutoCAD SHX Text 2.9'
AutoCAD SHX Text 21.8'
AutoCAD SHX Text 15.1'
AutoCAD SHX Text 15.7'
AutoCAD SHX Text 41.3'
AutoCAD SHX Text 39.1'
AutoCAD SHX Text 45.8'
AutoCAD SHX Text 61.1'
AutoCAD SHX Text 45.9'
AutoCAD SHX Text 60.4'
AutoCAD SHX Text 7.9'
AutoCAD SHX Text 5.3'
AutoCAD SHX Text 15.3'
AutoCAD SHX Text 19.4'
AutoCAD SHX Text 2.5'
AutoCAD SHX Text 13.3'
AutoCAD SHX Text 2.5'
AutoCAD SHX Text 23.4'
AutoCAD SHX Text 66.6'
AutoCAD SHX Text 56.3'
AutoCAD SHX Text 43.4'
AutoCAD SHX Text 5.3'
AutoCAD SHX Text 20.0'
AutoCAD SHX Text 8.6'
AutoCAD SHX Text 21.5'
AutoCAD SHX Text 9.4'
AutoCAD SHX Text 4.0'
AutoCAD SHX Text 9.0'
AutoCAD SHX Text 16.9'
AutoCAD SHX Text 7.1'
AutoCAD SHX Text STORM SEWER MANHOLE TOP RIM ELEV = 31.02 NE INV ELEV = 25.34 (12" CLAY) E INV ELEV = 14.65 (24" CLAY) SE INV ELEV = 24.90 (12" CLAY) S INV ELEV = 14.66 (30" RCP) W INV ELEV = 14.62 (24" CLAY) BOTTOM ELEV = 14.6 ±
AutoCAD SHX Text FLAT GRATE INLET TOP GRATE ELEV = 30.59 N INV ELEV = 28.64 (12" CLAY) SW INV ELEV = 28.49 (12" CLAY) BOTTOM ELEV = 28.4±
AutoCAD SHX Text STORM SEWER MANHOLE TOP RIM ELEV = 30.97 N INV ELEV = 25.84 (15" RCP) E INV ELEV = 25.20 (15" RCP) S INV ELEV = 26.01 (15" RCP) SW INV ELEV = 26.29 (15" RCP) BOTTOM ELEV = 25.2±
AutoCAD SHX Text FLAT GRATE INLET TOP GRATE ELEV = 30.59 NW INV ELEV = 27.94 (12" CLAY) BOTTOM ELEV = 27.9±
AutoCAD SHX Text STORM SEWER MANHOLE TOP RIM ELEV = 31.56 E INV ELEV = 14.82 (24" CLAY) SW INV ELEV = 25.05 (15" CLAY) W INV ELEV = FULL OF DIRT (24" CLAY) BOTTOM ELEV = 14.8±
AutoCAD SHX Text FLAT GRATE INLET TOP GRATE ELEV = 34.84 SW INV ELEV = 31.22 (18" CPP) BOTTOM ELEV = 29.3±
AutoCAD SHX Text FLAT GRATE INLET TOP GRATE ELEV = 36.36 SE INV ELEV = 31.02 (18" RCP) BOTTOM ELEV = 30.6±
AutoCAD SHX Text STORM SEWER MANHOLE TOP RIM ELEV = 37.57 S INV ELEV = 30.88 (24" RCP) NW INV ELEV = 30.99 (24" CPP) BOTTOM ELEV = 30.8±
AutoCAD SHX Text FLAT GRATE INLET TOP GRATE ELEV = 33.08 NE INV ELEV = 30.71 (18" CPP) SW INV ELEV = 29.08 (18"RCP) BOTTOM ELEV = 29.0±
AutoCAD SHX Text STORM SEWER MANHOLE W/METAL GRATE INSIDE STRUCTURE TOP RIM ELEV = 38.49 TOP METAL GRATE ELEV = 38.13 SE INV ELEV = 33.90 (12" CPP) N INV ELEV = 34.39 (CVS, CLAY) W INV ELEV = 34.50 (8" PVC) S CVS PIPE INACCESSIBLE
AutoCAD SHX Text FLAT GRATE INLET TOP GRATE ELEV = 37.90 W INV ELEV = 36.50 (CVS) BOTTOM ELEV = 35.95
AutoCAD SHX Text FLAT GRATE INLET TOP GRATE ELEV = 37.86 W INV ELEV = 36.00 (CVS) BOTTOM ELEV = 35.41
AutoCAD SHX Text FLAT GRATE INLET TOP GRATE ELEV = 37.89 W INV ELEV = 36.23 (CVS) BOTTOM ELEV = 35.70
AutoCAD SHX Text FLAT GRATE INLET TOP GRATE ELEV = 38.05 E INV ELEV = 36.27 (CVS) BOTTOM ELEV = 35.84
AutoCAD SHX Text FLAT GRATE INLET TOP GRATE ELEV = 38.02 E INV ELEV = 36.32 (CVS) BOTTOM ELEV = 35.71
AutoCAD SHX Text FLAT GRATE INLET TOP GRATE ELEV = 38.01 E INV ELEV = 36.01 (CVS) BOTTOM ELEV = 35.48
AutoCAD SHX Text FLAT GRATE INLET TOP GRATE ELEV = 38.30 NW INV ELEV = 34.28 (8" CLAY) S PIPE INACCESSIBLE (CVS, BELL END)
AutoCAD SHX Text FLAT GRATE INLET TOP GRATE ELEV = 37.98 NE CVS PIPE INACCESSIBLE (CVS, BELL END) S INV ELEV = 33.99 (8" CLAY)
AutoCAD SHX Text SANITARY SEWER MANHOLE TOP RIM ELEV = 33.50 N INV ELEV = 23.93 (10" CVT) E INV ELEV = 23.65 (CVS CLAY) S INV ELEV = 23.53 (12" CVT) NW INV ELEV = 28.23 (8" CVT) BOTTOM ELEV = 23.5±
AutoCAD SHX Text STORM SEWER MANHOLE TOP RIM ELEV = 33.56 N INV ELEV = 25.30 (48" RCP) NE INV ELEV = 28.73 (18" RCP) S INV ELEV = 25.30 (48" RCP) BOTTOM ELEV = 25.3±
AutoCAD SHX Text SANITARY SEWER MANHOLE TOP RIM ELEV = 31.34 E INV ELEV = 25.06 (CVS CLAY) SE INV ELEV = 27.43 (6" CVT) W INV ELEV = 24.99 (CVS CLAY) BOTTOM ELEV = 24.9±
AutoCAD SHX Text FLAT GRATE INLET TOP GRATE ELEV = 38.58 E INV ELEV = 32.64 (18" HDPP) S INV ELEV = 36.93 (8" HDPP) NW INV ELEV = 32.68 (12" HDPP) BOTTOM ELEV = 32.6±
AutoCAD SHX Text FLAT GRATE INLET TOP GRATE ELEV = 37.86 E INV ELEV = 33.78 (6" HDPP) S INV ELEV = 32.25 (18" HDPP) SW INV ELEV = 32.26 (18" HDPP) BOTTOM ELEV = 32.2±
AutoCAD SHX Text FLAT GRATE INLET TOP GRATE ELEV = 39.24 N INV ELEV = 34.80 (18" CPP) E INV ELEV = 35.52 (8" CPP) SE INV ELEV = 33.84 (24" CPP) BOTTOM ELEV = 33.4±
AutoCAD SHX Text FLAT GRATE INLET TOP GRATE ELEV = 36.57 SE INV ELEV = 31.43 (24" CPP) NW INV ELEV = 31.90 (24" CPP) BOTTOM ELEV = 31.0±
AutoCAD SHX Text
MES INV ELEV = 31.02 (18" HDPP)
AutoCAD SHX Text
MES INV ELEV = 31.02 (24" HDPP)
AutoCAD SHX Text
MES INV ELEV = 32.24 (12" HDPP)
AutoCAD SHX Text
MES INV ELEV = 32.05 (18" HDPP)
J:\D0942\Civil\DWG\_Current_Plan_Set\D0942 - DEMO.dwg, 1/2/2025 5:08:00 PM, Amir Khorramian, , 1/2/2025 5:08:00 PM, Amir Khorramian, 1/2/2025 5:08:00 PM, Amir Khorramian, , Amir Khorramian, Amir Khorramian, , SITE BENCHMARK #506
SITE BENCHMARK #501
SITE BENCHMARK #516
SITE BENCHMARK #504
SITE BENCHMARK #522
E EUCLID AVENUE
S A
LA
B
A M
A A
VE
N
U E
500 West Fulton Street Sanford, FL 32771 Ph: 407.322.6841
D at e N o.
R ev is io n www.cphcorp.com
123456
C 2025
THIS SHEET NOT VALID FOR
CONSTRUCTION WITHOUT
COMPLETE SET OF PLANS.
Sheet No.
Drawn:
Designed:
Checked:
Job No.:
Date:
SP
EC
M A
R
TI
N M
EM
O
R
IA
L
ST
A D
IU
M
0.
E . E uc lid
A ve
D eL an d, F lo rid a
D0942
Building Better Communities Together
CPH CONSULTING ,LLC
A Full Service A &E Firm
Plans Prepared By:
C1.3
ST
O
R M
W A
TE
R
P O
LL
U
TI
O
N
PR
EV
EN
TI
O
N P
LA
N
J. DYMEK
K. BERLINSKY
L. WRAY
09/03/2024
H O
W
AR
D L
. W R
AY
F.
L.
P
.E . N
O .5
/0
1/
PE
R
C
IT
Y C
O M
M
EN
TS
/1
5/
PE
R
C
IT
Y C
O M
M
EN
TS
HOWARD L. WRAY, STATE OF FLORIDA,
PROFESSIONAL ENGINEER, LICENSE NO. 55557
THIS ITEM HAS BEEN DIGITALLY SIGNED AND
SEALED BY HOWARD L. WRAY ON THE DATE
INDICATED HERE. PRINTED COPIES OF THIS
DOCUMENT ARE NOT CONSIDERED SIGNED
AND SEALED AND THE SIGNATURE MUST BE
VERIFIED ON ANY ELECTRONIC COPIES.
MATCH LINE A - SEE MATCH LINE B BELOW
Graphic Scale in Feet
20 20 40 N www.sunshine811.com
SILT FENCE
LIMITS OF DISTURBANCE
LEGEND
INLET PROTECTION (SEE SHEET C-1.5 FOR DETAILS)
PROPOSED STORM PIPING
PROPOSED TRENCH DRAIN
TEMPORARY CONSTRUCTION EXITCE
SWPPP INFORMATION SIGNSS
EXISTING STORM PIPING
SOIL TYPE ASTATULA-URBAN LAND
COMPLEX, 0 TO 8 PERCENT SLOPES
PERMANENT SEEDING, SOD, OR
MULCHING FOR ANY DISTURBED AREAS
DISTURBED TURF TO BE REPLACED IN KIND
FLOW DIRECTION
AutoCAD SHX Text 51.9'
AutoCAD SHX Text 12.8'
AutoCAD SHX Text 10.6'
AutoCAD SHX Text 10.7'
AutoCAD SHX Text 30.8'
AutoCAD SHX Text 10.7'
AutoCAD SHX Text 10.7'
AutoCAD SHX Text 12.8'
AutoCAD SHX Text 40.5'
AutoCAD SHX Text 20.1'
AutoCAD SHX Text 47.1'
AutoCAD SHX Text 20.4'
AutoCAD SHX Text 6.6'
AutoCAD SHX Text 7.0'
AutoCAD SHX Text 20.4'
AutoCAD SHX Text 47.1'
AutoCAD SHX Text 20.1'
AutoCAD SHX Text 40.1'
AutoCAD SHX Text
LAWN MOWER DOCKING
AutoCAD SHX Text
ELEC TRANS
AutoCAD SHX Text
BREAKERS
AutoCAD SHX Text 7.5'
AutoCAD SHX Text 15.0'
AutoCAD SHX Text 7.5'
AutoCAD SHX Text 5.9'
AutoCAD SHX Text 16.7'
AutoCAD SHX Text 9.0'
AutoCAD SHX Text 4.1'
AutoCAD SHX Text 9.5'
AutoCAD SHX Text 41.5'
AutoCAD SHX Text 56.3'
AutoCAD SHX Text
BFP (2) & UNK RISER
AutoCAD SHX Text
ASPHALT PAVEMENT
AutoCAD SHX Text
ASPHALT PAVEMENT
AutoCAD SHX Text
ASPHALT PAVEMENT
AutoCAD SHX Text
ASPHALT PAVEMENT
AutoCAD SHX Text
ASPHALT PAVEMENT
AutoCAD SHX Text
ASPHALT PAVEMENT
AutoCAD SHX Text
CONCRETE
AutoCAD SHX Text
CONCRETE
AutoCAD SHX Text
BRICK PAVERS
AutoCAD SHX Text
STADIUM LIGHT POLE
AutoCAD SHX Text
SCORE BOARD
AutoCAD SHX Text
BFP
AutoCAD SHX Text
BFP
AutoCAD SHX Text
OVERHANG
AutoCAD SHX Text
THREE STORY BUILDING FF ELEV = 41.80 (NAVD '88)
AutoCAD SHX Text
SINGLE STORY CONC BLOCK BUILDING FF ELEV = 52.48 (NAVD '88)
AutoCAD SHX Text
SINGLE STORY CONC BLOCK BUILDING FF ELEV = 52.47 (NAVD '88)
AutoCAD SHX Text
SINGLE STORY CONC BLOCK BUILDING FF ELEV = 52.63 (NAVD '88)
AutoCAD SHX Text
BRICK PAVERS
AutoCAD SHX Text
BRICK PAVERS
AutoCAD SHX Text
6' CLF
AutoCAD SHX Text
6' CLF WITH BARBED WIRE ON TOP
AutoCAD SHX Text
6' CLF
AutoCAD SHX Text
6' CLF
AutoCAD SHX Text
6' CLF
AutoCAD SHX Text
GATE
AutoCAD SHX Text
4' CLF
AutoCAD SHX Text
6' CLF
AutoCAD SHX Text
4' CLF
AutoCAD SHX Text
COLUMN (TYP)
AutoCAD SHX Text
8' WIF
AutoCAD SHX Text
PLATFORM
AutoCAD SHX Text
FOOTBALL FIELD
AutoCAD SHX Text
4' CLF
AutoCAD SHX Text
4' CLF
AutoCAD SHX Text
6' CLF
AutoCAD SHX Text
6' CLF
AutoCAD SHX Text
BRICK PAVERS
AutoCAD SHX Text
ELEC PULL BOX
AutoCAD SHX Text
CLEAN OUT
AutoCAD SHX Text
ELEC PULL BOX
AutoCAD SHX Text
PULL BOX
AutoCAD SHX Text
PULL BOX
AutoCAD SHX Text
PULL BOX, ELEC METER, ELEC PANEL
AutoCAD SHX Text
ELEC TRANS
AutoCAD SHX Text FLAT GRATE INLET TOP GRATE ELEV = 37.93 W INV ELEV = 36.58 (CVS) BOTTOM ELEV = 36.03
AutoCAD SHX Text FLAT GRATE INLET TOP GRATE ELEV = 37.93 W INV ELEV = 36.13 (CVS) BOTTOM ELEV = 35.60
AutoCAD SHX Text FLAT GRATE INLET TOP GRATE ELEV = 37.95 W INV ELEV = 36.20 (CVS) BOTTOM ELEV = 35.57
AutoCAD SHX Text FLAT GRATE INLET TOP GRATE ELEV = 37.95 W INV ELEV = 36.41 (CVS) BOTTOM ELEV = 35.80
AutoCAD SHX Text FLAT GRATE INLET TOP GRATE ELEV = 38.17 N INV ELEV = 36.63 (CVS RCP) SE INV ELEV = 36.52 (6" CLAY)
AutoCAD SHX Text FLAT GRATE INLET TOP GRATE ELEV = 38.26 N INV ELEV = 36.63 (CVS RCP) SW INV ELEV = 36.58 (CVS CLAY)
AutoCAD SHX Text FLAT GRATE INLET TOP GRATE ELEV = 38.04 E INV ELEV = 36.13 (CVS) BOTTOM ELEV = 35.66
AutoCAD SHX Text FLAT GRATE INLET TOP GRATE ELEV = 38.05 E INV ELEV = 35.70 (CVS) BOTTOM ELEV = 35.05
AutoCAD SHX Text FLAT GRATE INLET TOP GRATE ELEV = 38.04 E INV ELEV = 36.04 (CVS) BOTTOM ELEV = 35.51
AutoCAD SHX Text FLAT GRATE INLET TOP GRATE ELEV = 38.05 E INV ELEV = 36.05 (CVS) BOTTOM ELEV = 35.66
AutoCAD SHX Text FLAT GRATE INLET TOP GRATE ELEV = 38.05 E INV ELEV = 36.27 (CVS) BOTTOM ELEV = 35.84
AutoCAD SHX Text FLAT GRATE INLET TOP GRATE ELEV = 44.80 S INV ELEV = 38.68 (18" CPP) BOTTOM ELEV = 38.4±
AutoCAD SHX Text FLAT GRATE INLET TOP GRATE ELEV = 39.24 N INV ELEV = 34.80 (18" CPP) E INV ELEV = 35.52 (8" CPP) SE INV ELEV = 33.84 (24" CPP) BOTTOM ELEV = 33.4±
AutoCAD SHX Text FLAT GRATE INLET TOP GRATE ELEV = 51.52 E INV ELEV = 48.36 (15"CMP) SW INV ELEV = 47.58 (36" CMP) BOTTOM ELEV = 47.5±
AutoCAD SHX Text FLAT GRATE INLET TOP GRATE ELEV = 50.86 E INV ELEV = 48.48 (8" PVC) S INV ELEV = 48.54 (4" PVC) W INV ELEV = 48.48 (15" CMP) BOTTOM ELEV = 48.4±
AutoCAD SHX Text FLAT GRATE INLET TOP GRATE ELEV = 50.67 S INV ELEV = 48.92 (4 "PVC) W INV ELEV = 48.01 (8" PVC) BOTTOM ELEV = 47.8±
AutoCAD SHX Text
GRASS
AutoCAD SHX Text
GRASS
AutoCAD SHX Text
GRASS
AutoCAD SHX Text
GRASS
AutoCAD SHX Text
GRASS
AutoCAD SHX Text
GRASS
AutoCAD SHX Text
GRASS
AutoCAD SHX Text
GRASS
AutoCAD SHX Text
GRASS
AutoCAD SHX Text
GRASS
AutoCAD SHX Text
GRASS
AutoCAD SHX Text
GRASS
AutoCAD SHX Text
GRASS
AutoCAD SHX Text
GRASS
AutoCAD SHX Text
GRASS
AutoCAD SHX Text
GRASS
AutoCAD SHX Text
GRASS
AutoCAD SHX Text
ELEC
AutoCAD SHX Text
ELEC
AutoCAD SHX Text
FLAG POLE
AutoCAD SHX Text
FLAT GRATE INLET TOP GRATE ELEV = 43.61 INACCESSIBLE
AutoCAD SHX Text
STORM SEWER MANHOLE TOP RIM ELEV = 43.75 INACCESSIBLE
AutoCAD SHX Text
STORM SEWER MANHOLE TOP RIM ELEV = 44.32 INACCESSIBLE
J:\D0942\Civil\DWG\_Current_Plan_Set\D0942 - STORMWATER POLLUTION PREVENTION.dwg, 1/2/2025 5:08:15 PM, Amir Khorramian, , 1/2/2025 5:08:15 PM, Amir Khorramian, 1/2/2025 5:08:15 PM, Amir Khorramian, , Amir Khorramian, Amir Khorramian, , E HUBBARD AVENUE
S A
LA
B
A M
A A
VE
N
U E 50'
26'
CE
SS
500 West Fulton Street Sanford, FL 32771 Ph: 407.322.6841
D at e N o.
R ev is io n www.cphcorp.com
123456
C 2025
THIS SHEET NOT VALID FOR
CONSTRUCTION WITHOUT
COMPLETE SET OF PLANS.
Sheet No.
Drawn:
Designed:
Checked:
Job No.:
Date:
SP
EC
M A
R
TI
N M
EM
O
R
IA
L
ST
A D
IU
M
0.
E . E uc lid
A ve
D eL an d, F lo rid a
D0942
Building Better Communities Together
CPH CONSULTING ,LLC
A Full Service A &E Firm
Plans Prepared By:
C1.4
ST
O
R M
W A
TE
R
P O
LL
U
TI
O
N
PR
EV
EN
TI
O
N P
LA
N
J. DYMEK
K. BERLINSKY
L. WRAY
09/03/2024
H O
W
AR
D L
. W R
AY
F.
L.
P
.E . N
O .5
/0
1/
PE
R
C
IT
Y C
O M
M
EN
TS
/1
5/
PE
R
C
IT
Y C
O M
M
EN
TS
EROSION AND SEDIMENT CONTROL
1. EROSION AND SEDIMENT CONTROL MEASURES ARE TO BE PROVIDED AND INSTALLED PRIOR TO
COMMENCEMENT OF CONSTRUCTION. SEDIMENT CONTROL CONSISTS OF SILT FENCING
(SEDIMENT BARRIER) AND FLOATING TURBIDITY BARRIERS PER DETAILS ON THE DRAWINGS.
EROSION CONTROL CONSISTS OF SEEDING AND MULCHING, HYDROSEEDING, SODDING,
WETTING SURFACES, PLACEMENT OF COARSE AGGREGATE, TEMPORARY PAVING.
2. MAINTAIN TEMPORARY EROSION CONTROL SYSTEMS AS DIRECTED BY OWNER OR GOVERNING
AUTHORITIES TO CONTROL EROSION AND SILTATION DURING LIFE OF CONTRACT. OWNER HAS
AUTHORITY TO LIMIT SURFACE AREA OF ERODIBLE EARTH MATERIAL EXPOSED BY CLEARING
AND GRUBBING, EXCAVATION, TRENCHING, BORROW AND EMBANKMENT OPERATIONS. OWNER
ALSO HAS AUTHORITY TO DIRECT CONTRACTOR TO PROVIDE IMMEDIATE PERMANENT OR
TEMPORARY EROSION AND SEDIMENT CONTROL MEASURES.
3. CONTRACTOR SHALL RESPOND TO EROSION AND SEDIMENT CONTROL MAINTENANCE
REQUIREMENTS OR IMPLEMENT ADDITIONAL MEASURES TO CONTROL EROSION ORDERED BY
OWNER OR GOVERNING AUTHORITIES WITHIN 48 HOURS OR SOONER IF REQUIRED AT NO
ADDITIONAL COST TO THE OWNER.
4. CONTRACTOR WILL BE REQUIRED TO INCORPORATE PERMANENT EROSION CONTROL FEATURES
INTO PROJECT AT EARLIEST PRACTICAL TIME TO MINIMIZE NEED FOR TEMPORARY CONTROLS.
5. THE EROSION AND SEDIMENT CONTROL MEASURES SHOWN ON THE PLANS REPRESENT A
MINIMUM REQUIREMENT. THE CONTRACTOR IS RESPONSIBLE FOR DETERMINING ADDITIONAL
EROSION AND SEDIMENT CONTROL MEASURES NEEDED IN ORDER TO PREVENT THE TRANSFER
OF SEDIMENT FROM THE PROJECT AREA AND PREVENT THE EROSION OF SURFACES DURING
CONSTRUCTION, AS NEEDED TO PROTECT ADJACENT PROPERTIES AND WATER BODIES.
6. GRASS ALL DISTURBED AREAS WITHIN 7 DAYS OF INITIAL DISTURBANCE. TYPE OF GRASSING
SHALL BE AS FOLLOWS: TEMPORARY GRASSING TO BE SODDING AT ALL DRAINAGE
STRUCTURES, RETENTION AREAS, SWALES AND DITCHES, AND WHERE SLOPES ARE STEEPER
THAN 5:1. TEMPORARY GRASSING CAN BE HYDROSEEDING OR SEED AND MULCH AT ALL OTHER
LOCATIONS UNLESS OTHERWISE INDICATED IN THE DRAWINGS OR SPECIFICATIONS.
7. INSPECT EVERY WEEK DURING CONSTRUCTION. REMOVE ANY SEDIMENT BUILD-UP. REPAIR
AND REINSTALL ANY DAMAGED OR MISSING SEDIMENT CONTROL MEASURES. INSTALL
ADDITIONAL MEASURES IF INSPECTION REVEALS ADDITIONAL SEDIMENTATION CONTROL IS
NECESSARY.
8. AREAS TO BE PAVED SHALL BE TREATED WITH A BITUMINOUS PRIME COAT AND SANDED TO
MINIMIZE EROSION, WHERE PAVING IS SCHEDULED TO OCCUR MORE THAN 48 HOURS AFTER
INSTALLATION OF BASE COURSE. AREAS TO RECEIVE CONCRETE PAVING SHALL BE EITHER
PROTECTED WITH A LAYER OF FDOT COARSE AGGREGATE MATERIAL OR SHALL BE PAVED
WITHIN 48 HOURS OF INSTALLATION OF THE SUBGRADE. INSTALL FINAL SURFACE COURSES
WITHIN 14 DAYS AFTER REMOVAL OF EXISTING PAVEMENT.
HOWARD L. WRAY, STATE OF FLORIDA,
PROFESSIONAL ENGINEER, LICENSE NO. 55557
THIS ITEM HAS BEEN DIGITALLY SIGNED AND
SEALED BY HOWARD L. WRAY ON THE DATE
INDICA…