B08_Solicitation_Attch_4_SOW_PULL_window_asbuilts.pdf
PDF 960 KB Posted
- Attached to
- PULLMAN NATIONAL MONUMENT WINDOW WASHING SERVICES Federal contract opportunity
- Solicitation number
- 140P6222Q0002
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| A04_SOW_(PULL_Window_Washing)_Amended_12Apr22_0003.pdf | ||
| Q_A_PULL_Window_Washing_v2_12Apr22_0003.pdf | ||
| Sol_140P6222Q0002_Amd_0003.pdf | ||
| B08 Solicitation Attch 7 (Q and A PULL Window Washing_4Apr22).pdf | ||
| Sol_140P6222Q0002_Amd_0002.pdf | ||
| Sol_140P6222Q0002_Amd_0001.pdf | ||
| B08_Solicitation_Attch_3_(Wage_Determination_2015_5017).pdf | ||
| B08_Solicitation_Attch_1_(SOW).pdf | ||
| B08_Attch_6_(Price_Schedule)_.xlsx | XLSX spreadsheet | |
| B08_Solicitation_Attch_5_(SOW_Map).pdf | ||
| Sol_140P6222Q0002.pdf | ||
| B08_Solicitation_Attch_2_(Experience_Questionnaire).pdf |
Show all 12
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
z
_J w
I w
N <t:
<.'.J z w _J w
I w
N
N N
I
<.'.J z
O'.'.
O'.'.
u w O'.'.
<t:
u
1-z w ::::J u z
1-u ::::J O'.'.
I z u
(0 w u
O'.'.
w w _J
I I-
_J _J
::::J [l_
[l_ z
(Jl (0 N e
X
N O'.'.
N
ID
1 WEST ELEVATION
SCALE@
1..-,;;,,,,..--...... ---- ,,,,.--.,. -- ,,,,.--.,.
iiiiiiiiiiiliiiiii iiiiiiiiiiiiiiiili jjjjjjjjjjjjjjjjj
10 W10 10
111111111111111111 HIIIIIIIIIIIIIIH
mm 11111111111 iiiiiiiiiiiiiiiiii iiiiiiiiiiiiiiiiii
I
N
I.
(Jl N
8 0 8
I
N
P SCALE@ ---
SCALE OF FEET
NOTES:
1.
LEGEND:
2008 NEW MASONRY CONSTRUCTION. AREAS NOT SHOWN AS NEW
MASONRY CONSTRUCTION NEED TO COMPLY WITH HISTORIC
MASONRY REQUIREMENTS PER SPECIFICATIONS.
LOCATION OF GROUNDING CABLE FOR
LIGHTNING PROTECTION SYSTEM
DESIGNED: SUB SHEET NO. TITLE OF SHEET
JGWA
ADMINISTRATION BUILDING
@LiilijJ
LMS, CS
A2.0
WEST ELEVATION
TECH. REVIEW:
NAR
DATE: PULLMAN NATIONAL MONUMENT
05/04/2020 CHICAGO, ILLINOIS
DRAWING NO.
135749
PMIS/PKG NO.
250673B & 238559C
SHEET
07 OF 1 6
AutoCAD SHX Text
XII
AutoCAD SHX Text
XI
AutoCAD SHX Text X
AutoCAD SHX Text
IX
AutoCAD SHX Text
VIII
AutoCAD SHX Text
VII
AutoCAD SHX Text
VI
AutoCAD SHX Text V
AutoCAD SHX Text
VI
AutoCAD SHX Text
III
AutoCAD SHX Text
II
AutoCAD SHX Text I
AutoCAD SHX Text N
AutoCAD SHX Text S
AutoCAD SHX Text
WEST ELEVATION
AutoCAD SHX Text A2.0
AutoCAD SHX Text
AutoCAD SHX Text
%%U WEST ELEVATION
AutoCAD SHX Text A2.0
AutoCAD SHX Text
SCALE
AutoCAD SHX Text B
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
SCALE OF FEET
AutoCAD SHX Text
SCALE
AutoCAD SHX Text B
AutoCAD SHX Text
AutoCAD SHX Text W307
AutoCAD SHX Text W306
AutoCAD SHX Text W301
AutoCAD SHX Text W300
AutoCAD SHX Text W600
AutoCAD SHX Text W602
AutoCAD SHX Text W601
AutoCAD SHX Text W500
AutoCAD SHX Text W302
AutoCAD SHX Text W305
AutoCAD SHX Text W304
AutoCAD SHX Text W303
AutoCAD SHX Text W204
AutoCAD SHX Text W205
AutoCAD SHX Text W206
AutoCAD SHX Text W203
AutoCAD SHX Text W209
AutoCAD SHX Text W208
AutoCAD SHX Text W207
AutoCAD SHX Text W200
AutoCAD SHX Text W201
AutoCAD SHX Text W202
AutoCAD SHX Text W103
AutoCAD SHX Text W104
AutoCAD SHX Text W105
AutoCAD SHX Text W106
AutoCAD SHX Text W107
AutoCAD SHX Text W108
AutoCAD SHX Text W102
AutoCAD SHX Text W101
AutoCAD SHX Text W100
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
DESIGNED:
AutoCAD SHX Text
TECH. REVIEW:
AutoCAD SHX Text
SUB SHEET NO.
AutoCAD SHX Text
PMIS/PKG NO.
AutoCAD SHX Text
DRAWING NO.
AutoCAD SHX Text
SHEET
AutoCAD SHX Text
OF
AutoCAD SHX Text
TITLE OF SHEET
AutoCAD SHX Text
ADMINISTRATION BUILDING
AutoCAD SHX Text
PULLMAN NATIONAL MONUMENT CHICAGO, ILLINOIS
AutoCAD SHX Text 05/04/2020
AutoCAD SHX Text
NAR
AutoCAD SHX Text
LMS, CS
AutoCAD SHX Text
JGWA
AutoCAD SHX Text 250673B & 238559C
AutoCAD SHX Text
AutoCAD SHX Text 590 135749
AutoCAD SHX Text PROTECT STABILIZED WALL AND ASSOCIATED STRUCTURAL BRACING ADJACENT TO PROJECT SITE, TYPICAL.
AutoCAD SHX Text NOTES: 1. REFER TO A3-SERIES SHEETS FOR WINDOW SCOPE OF WORK. REFER TO A3-SERIES SHEETS FOR WINDOW SCOPE OF WORK. 2. NO WORK AT MASONRY, TYPICAL. PROTECT MASONRY SURFACES NO WORK AT MASONRY, TYPICAL. PROTECT MASONRY SURFACES AND ELEMENTS TO REMAIN. 3. REFER TO A1-SERIES SHEETS FOR SNOW GUARD LAYOUT REFER TO A1-SERIES SHEETS FOR SNOW GUARD LAYOUT CONFIGURATIONS. 4. REFER TO SPECIFICATIONS AND SHEETS C1.0, R1.0, AND A1.0 REFER TO SPECIFICATIONS AND SHEETS C1.0, R1.0, AND A1.0 FOR NOTES REGARDING PROTECTION OF ITEMS ADJACENT TO CONSTRUCTION ACTIVITIES. 5. REFER TO SHEET A5.0 FOR ADDITIONAL INFORMATION ABOUT NEW REFER TO SHEET A5.0 FOR ADDITIONAL INFORMATION ABOUT NEW LIGHTNING PROTECTION SYSTEM. 6. CONTRACTOR IS TO MAKE ALL MASONRY REPAIRS NECESSARY CONTRACTOR IS TO MAKE ALL MASONRY REPAIRS NECESSARY FOR THE INSTALLATION OF NEW WINDOWS.
AutoCAD SHX Text 2008 NEW MASONRY CONSTRUCTION. AREAS NOT SHOWN AS NEW MASONRY CONSTRUCTION NEED TO COMPLY WITH HISTORIC MASONRY REQUIREMENTS PER SPECIFICATIONS.
AutoCAD SHX Text
LEGEND:
AutoCAD SHX Text
LOCATION OF GROUNDING CABLE FOR LIGHTNING PROTECTION SYSTEM
AutoCAD SHX Text 5/1/20 R24 X:\18F0269 NPS PULL TITLE III SERVICES\06 - CONSTRUCTION DOCUMENTS\01 CAD\RECORD DRAWINGS 04-2020\A2.0 - WEST ELEVATION.DWG A2.0 - WEST ELEVATION R24 X:\18F0269 NPS PULL TITLE III SERVICES\06 - CONSTRUCTION DOCUMENTS\01 CAD\RECORD DRAWINGS 04-2020\A2.0 - WEST ELEVATION.DWG A2.0 - WEST ELEVATIONX:\18F0269 NPS PULL TITLE III SERVICES\06 - CONSTRUCTION DOCUMENTS\01 CAD\RECORD DRAWINGS 04-2020\A2.0 - WEST ELEVATION.DWG A2.0 - WEST ELEVATION A2.0 - WEST ELEVATIONA2.0 - WEST ELEVATION
AutoCAD SHX Text REFER TO SHEET A1.0 FOR SCOPE OF ROOF REPLACEMENT WORK AT MANSARD AND STEEP SLOPE ROOF AREAS, INCLUSIVE OF DORMER CONSTRUCTION. EXISTING ROOF DRAINAGE SYSTEM TO REMAIN, TYPICAL.
AutoCAD SHX Text
REFER TO SHEET A1.1 FOR SCOPE OF ROOF REPLACEMENT WORK AT TOWER.
AutoCAD SHX Text EXISTING WEATHERVANE ATOP FLAGPOLE. REFER TO SHEET A1.1 FOR SCOPE OF WORK, THIS ELEMENT.
AutoCAD SHX Text
NO WORK AT MASONRY OPENING W104 (FUTURE DOOR).
AutoCAD SHX Text LOCATE NEW LIGHTNING PROTECTION GROUNDING CABLE BEHIND EXISTING ROOF DOWNSPOUT TO REMAIN, TYPICAL OF (2) LOCATIONS, THIS ELEVATION.
AutoCAD SHX Text
PROTECT NORTH WING ROOF ADJACENT TO PROJECT SITE.
AutoCAD SHX Text
REFER TO SHEET A4.1 FOR STEEP SLOPE ROOF DETAILS.
AutoCAD SHX Text PER PUNCH LIST ITEM 65, DATED 12/23/2019, CONTRACTOR WAS UNABLE TO DOCUMENT HOW THE EXISTING WEATHERVANE WAS RE-SECURED TO THE TOP OF THE FLAGPOLE AND HOW THE REPAIRS WERE CARRIED OUT. NO REFINISHING WORK OF FLAGPOLE OR WEATHERVANE WAS COMPLETED. PER MEETING MINUTES, DATED 10/17/19, NPS ACTING SUPERINTENDENT STATED THAT AN AGREEMENT WILL BE REACHED BETWEEN NPS AND CONTRACTOR IF SOMETHING FAILS IN THE FUTURE.
AutoCAD SHX Text
AutoCAD SHX Text PER RFI 25, DATED 07/18/2019, AND RFP 2, DATED 08/02/2019, ALL EXTERIOR ALUMINUM STORM WINDOWS WERE FABRICATED AND FURNISHED, BUT NOT INSTALLED. THEY WERE PUT INTO STORAGE ON THE SECOND FLOOR UPON RECEIPT/ACCEPTANCE BY NPS.
AutoCAD SHX Text
AutoCAD SHX Text THESE RECORD DRAWINGS HAVE BEEN PRODUCED BY JOHN G. WAITE ASSOCIATES, ARCHITECTS IN MAY OF 2020, IN AN EFFORT TO IDENTIFY WHERE THE WORK COMPLETED BY THE CONTRACTOR DIFFERS FROM THE CONTRACT DOCUMENTS. INFORMATION PROVIDED ON THESE RECORD DRAWINGS HAS BEEN SOURCED FROM PROJECT RECORDS OBTAINED FROM THE CONTRACTOR, THE ARCHITECT, AND THE NATIONAL PARK SERVICE.
AutoCAD SHX Text
_J w I(/] i:5
N<t'.
c., s:0 z
_J w I(/] i:5
0N0N I �0
(/]c.,z
O'.'.0 0O'.'.
u w O'.'.
/0 <t'.
u
/(/]1-zw �::::Ju00 z 1-u ::::JO'.'.I(/]z u
(0 0 /(/] w u > O'.'.w(/] w _J f f-
_J _J ::::J [l_
[l_ z (Jl (0 N
00 � X
�NO'.'.
0 N I[)
1----
EAST ELEVATION
SCALE@
E300 E301
I
SCALE@
I[) r--
LEGEND:
2008 NEW MASONRY CONSTRUCTION. AREAS NOT SHOWN AS NEW
MASONRY CONSTRUCTION NEED TO COMPLY WITH HISTORIC
MASONRY REQUIREMENTS PER SPECIFICATIONS.
DESIGNED:
JGWA
0 8 @LiilijJ
LOCATION OF GROUNDING CABLE FOR
LIGHTNING PROTECTION SYSTEM
SUB SHEET NO. TITLE OF SHEET DRAWING NO.
135749
16 LMS, CS
A2.1
ADMINISTRATION BUILDING
EAST ELEVATION PMIS/PKG NO.
250673B & 238559C
SHEET
SCALE OF FEET TECH. REVIEW:
NAR
DATE:
05/04/2020
PULLMAN NATIONAL MONUMENT
CHICAGO, ILLINOIS 08 OF 1 6
AutoCAD SHX Text
XII
AutoCAD SHX Text
XI
AutoCAD SHX Text X
AutoCAD SHX Text
IX
AutoCAD SHX Text
VIII
AutoCAD SHX Text
VII
AutoCAD SHX Text
VI
AutoCAD SHX Text V
AutoCAD SHX Text
VI
AutoCAD SHX Text
III
AutoCAD SHX Text
II
AutoCAD SHX Text I
AutoCAD SHX Text N
AutoCAD SHX Text S
AutoCAD SHX Text
EAST ELEVATION
AutoCAD SHX Text A2.1
AutoCAD SHX Text
AutoCAD SHX Text
%%U EAST ELEVATION
AutoCAD SHX Text A2.1
AutoCAD SHX Text
SCALE
AutoCAD SHX Text B
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
SCALE OF FEET
AutoCAD SHX Text
SCALE
AutoCAD SHX Text B
AutoCAD SHX Text
AutoCAD SHX Text E305
AutoCAD SHX Text E306
AutoCAD SHX Text E307
AutoCAD SHX Text E302
AutoCAD SHX Text E301
AutoCAD SHX Text E300
AutoCAD SHX Text E303
AutoCAD SHX Text E304
AutoCAD SHX Text E207
AutoCAD SHX Text E200
AutoCAD SHX Text E202
AutoCAD SHX Text E201
AutoCAD SHX Text E204
AutoCAD SHX Text E205
AutoCAD SHX Text E203
AutoCAD SHX Text E209
AutoCAD SHX Text E210
AutoCAD SHX Text E208
AutoCAD SHX Text E212
AutoCAD SHX Text E213
AutoCAD SHX Text E211
AutoCAD SHX Text E206
AutoCAD SHX Text E106
AutoCAD SHX Text E110
AutoCAD SHX Text E112
AutoCAD SHX Text E111
AutoCAD SHX Text E107
AutoCAD SHX Text E109
AutoCAD SHX Text E108
AutoCAD SHX Text E103
AutoCAD SHX Text E105
AutoCAD SHX Text E104
AutoCAD SHX Text E101
AutoCAD SHX Text E102
AutoCAD SHX Text E100
AutoCAD SHX Text E601
AutoCAD SHX Text E602
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
DESIGNED:
AutoCAD SHX Text
TECH. REVIEW:
AutoCAD SHX Text
SUB SHEET NO.
AutoCAD SHX Text
PMIS/PKG NO.
AutoCAD SHX Text
DRAWING NO.
AutoCAD SHX Text
SHEET
AutoCAD SHX Text
OF
AutoCAD SHX Text
TITLE OF SHEET
AutoCAD SHX Text
ADMINISTRATION BUILDING
AutoCAD SHX Text
PULLMAN NATIONAL MONUMENT CHICAGO, ILLINOIS
AutoCAD SHX Text 05/04/2020
AutoCAD SHX Text
NAR
AutoCAD SHX Text
LMS, CS
AutoCAD SHX Text
JGWA
AutoCAD SHX Text 250673B & 238559C
AutoCAD SHX Text
AutoCAD SHX Text 590 135749
AutoCAD SHX Text LOCATE NEW LIGHTNING PROTECTION GROUNDING CABLE BEHIND EXISTING ROOF DOWNSPOUT TO REMAIN, TYPICAL OF (2) LOCATIONS, THIS ELEVATION.
AutoCAD SHX Text
NO WORK AT MASONRY OPENINGS E106 AND E112 (FUTURE DOORS).
AutoCAD SHX Text E600
AutoCAD SHX Text 5/1/20 R24 X:\18F0269 NPS PULL TITLE III SERVICES\06 - CONSTRUCTION DOCUMENTS\01 CAD\RECORD DRAWINGS 04-2020\A2.1 - EAST ELEVATION.DWG A2.1 - EAST ELEVATION R24 X:\18F0269 NPS PULL TITLE III SERVICES\06 - CONSTRUCTION DOCUMENTS\01 CAD\RECORD DRAWINGS 04-2020\A2.1 - EAST ELEVATION.DWG A2.1 - EAST ELEVATIONX:\18F0269 NPS PULL TITLE III SERVICES\06 - CONSTRUCTION DOCUMENTS\01 CAD\RECORD DRAWINGS 04-2020\A2.1 - EAST ELEVATION.DWG A2.1 - EAST ELEVATION A2.1 - EAST ELEVATIONA2.1 - EAST ELEVATION
AutoCAD SHX Text PROTECT STABILIZED WALL AND ASSOCIATED STRUCTURAL BRACING ADJACENT TO PROJECT SITE
AutoCAD SHX Text REFER TO SHEET A1.0 FOR SCOPE OF ROOF REPLACEMENT WORK AT MANSARD AND STEEP SLOPE ROOF AREAS, INCLUSIVE OF DORMER CONSTRUCTION. EXISTING ROOF DRAINAGE SYSTEM TO REMAIN, TYPICAL.
AutoCAD SHX Text
REFER TO SHEET A1.1 FOR SCOPE OF ROOF REPLACEMENT WORK AT TOWER.
AutoCAD SHX Text NOTES: 1. REFER TO A3-SERIES SHEETS FOR WINDOW SCOPE OF WORK. REFER TO A3-SERIES SHEETS FOR WINDOW SCOPE OF WORK. 2. NO WORK AT MASONRY, TYPICAL. PROTECT MASONRY SURFACES NO WORK AT MASONRY, TYPICAL. PROTECT MASONRY SURFACES AND ELEMENTS TO REMAIN. 3. REFER TO A1-SERIES SHEETS FOR SNOW GUARD LAYOUT REFER TO A1-SERIES SHEETS FOR SNOW GUARD LAYOUT CONFIGURATIONS. 4. REFER TO SPECIFICATIONS AND SHEETS C1.0, R1.0, AND A1.0 REFER TO SPECIFICATIONS AND SHEETS C1.0, R1.0, AND A1.0 FOR NOTES REGARDING PROTECTION OF ITEMS ADJACENT TO CONSTRUCTION ACTIVITIES. 5. REFER TO SHEET A5.0 FOR ADDITIONAL INFORMATION ABOUT NEW REFER TO SHEET A5.0 FOR ADDITIONAL INFORMATION ABOUT NEW LIGHTNING PROTECTION SYSTEM. 6. CONTRACTOR IS TO MAKE ALL MASONRY REPAIRS NECESSARY CONTRACTOR IS TO MAKE ALL MASONRY REPAIRS NECESSARY FOR THE INSTALLATION OF NEW WINDOWS.
AutoCAD SHX Text 2008 NEW MASONRY CONSTRUCTION. AREAS NOT SHOWN AS NEW MASONRY CONSTRUCTION NEED TO COMPLY WITH HISTORIC MASONRY REQUIREMENTS PER SPECIFICATIONS.
AutoCAD SHX Text
LEGEND:
AutoCAD SHX Text
LOCATION OF GROUNDING CABLE FOR LIGHTNING PROTECTION SYSTEM
AutoCAD SHX Text
PROTECT NORTH WING ROOF ADJACENT TO PROJECT SITE.
AutoCAD SHX Text TIE-IN NEW HORIZONTAL ROOF LEADER FROM SOUTH ELEVATION TO EXISTING DOWNSPOUT, THIS LOCATION.
AutoCAD SHX Text EXISTING WEATHERVANE ATOP FLAGPOLE. REFER TO SHEET A1.1 FOR SCOPE OF WORK, THIS ELEMENT.
AutoCAD SHX Text
REFER TO SHEET A4.1 FOR STEEP SLOPE ROOF DETAILS.
AutoCAD SHX Text
REFER TO SHEET A4.0 FOR MANSARD ROOF DETAILS.
AutoCAD SHX Text PER PUNCH LIST ITEM 65, DATED 12/23/2019, CONTRACTOR WAS UNABLE TO DOCUMENT HOW THE EXISTING WEATHERVANE WAS RE-SECURED TO THE TOP OF THE FLAGPOLE AND HOW THE REPAIRS WERE CARRIED OUT. NO REFINISHING WORK OF FLAGPOLE OR WEATHERVANE WAS COMPLETED. PER MEETING MINUTES, DATED 10/17/19, NPS ACTING SUPERINTENDENT STATED THAT AN AGREEMENT WILL BE REACHED BETWEEN NPS AND CONTRACTOR IF SOMETHING FAILS IN THE FUTURE.
AutoCAD SHX Text PER RFP 2, DATED 08/02/2019, DUE TO CONDITION AT MASONRY TO RECEIVE NEW ALUMINUM WINDOWS (MASONRY OPENINGS TO BE MODIFIED FROM DOOR OPENINGS TO WINDOW OPENINGS BY SUBSEQUENT MASONRY RESTORATION SUB-CONTRACTOR), WINDOW UNITS E105 AND E108 WERE FABRICATED AND FURNISHED TO THE NPS, BUT NOT INSTALLED. THEY WERE PUT INTO STORAGE ON THE SECOND FLOOR UPON RECEIPT/ACCEPTANCE BY NPS.
AutoCAD SHX Text
AutoCAD SHX Text THESE RECORD DRAWINGS HAVE BEEN PRODUCED BY JOHN G. WAITE ASSOCIATES, ARCHITECTS IN MAY OF 2020, IN AN EFFORT TO IDENTIFY WHERE THE WORK COMPLETED BY THE CONTRACTOR DIFFERS FROM THE CONTRACT DOCUMENTS. INFORMATION PROVIDED ON THESE RECORD DRAWINGS HAS BEEN SOURCED FROM PROJECT RECORDS OBTAINED FROM THE CONTRACTOR, THE ARCHITECT, AND THE NATIONAL PARK SERVICE.
AutoCAD SHX Text
AutoCAD SHX Text
WINDOW
AutoCAD SHX Text
WINDOW PERFORMANCE TESTING RESULTS
AutoCAD SHX Text E303
AutoCAD SHX Text WINDOW PERFORMANCE TESTING WAS PERFORMED ON AND WAS SUCCESSFULLY PASSED ON 10/18/19.
AutoCAD SHX Text E304
AutoCAD SHX Text WINDOW PERFORMANCE TESTING WAS PERFORMED ON AND WAS SUCCESSFULLY PASSED ON 01/22/20.
AutoCAD SHX Text E205
AutoCAD SHX Text WINDOW PERFORMANCE TESTING WAS PERFORMED ON AND WAS SUCCESSFULLY PASSED ON 01/13/20.
AutoCAD SHX Text E206
AutoCAD SHX Text WINDOW PERFORMANCE TESTING WAS PERFORMED ON AND WAS SUCCESSFULLY PASSED ON 12/13/19.
AutoCAD SHX Text E207
AutoCAD SHX Text WINDOW PERFORMANCE TESTING WAS PERFORMED ON AND WAS SUCCESSFULLY PASSED ON 01/22/20.
AutoCAD SHX Text E210
AutoCAD SHX Text WINDOW PERFORMANCE TESTING WAS PERFORMED ON AND WAS SUCCESSFULLY PASSED ON 01/13/20.
AutoCAD SHX Text E101
AutoCAD SHX Text WINDOW PERFORMANCE TESTING WAS PERFORMED ON 12/13/19. 1 DOUBLE HUNG & 2 FIXED PASSED AIR, 1 DOUBLE HUNG FAILED AIR. WINDOW PERFORMANCE TESTING WAS PERFORMED ON 01/13/20 WITH THE SAME RESULTS. WINDOW PERFORMANCE TESTING WAS PERFORMED AND SUCCESSFULLY PASSED ON 01/27/20.
AutoCAD SHX Text E103
AutoCAD SHX Text WINDOW PERFORMANCE TESTING WAS PERFORMED ON 10/19/19, WITH FIXED WINDOW PASSING AIR AND DOUBLE HUNG FAILING. WINDOW PERFORMANCE TESTING WAS PERFORMED AND WAS SUCCESSFULLY PASSED ON 11/04/19 AND 01/13/20.
AutoCAD SHX Text E104
AutoCAD SHX Text WINDOW PERFORMANCE TESTING WAS PERFORMED ON 10/18/19, WITH TWO FIXED AND RIGHT DOUBLE HUNG PASSING AND THE LEFT DOUBLE HUNG FAILING. WINDOW TESTING PERFORMANCE TESTING WAS PERFORMED AND WAS SUCCESSFULLY PASSED ON 12/13/19.
AutoCAD SHX Text E109
AutoCAD SHX Text WINDOW PERFORMANCE TESTING WAS PERFORMED ON AND WAS SUCCESSFULLY PASSED ON 01/23/20.
AutoCAD SHX Text E110
AutoCAD SHX Text WINDOW PERFORMANCE TESTING WAS PERFORMED ON 01/23/20, PASSING AIR AND FAILING WATER. WINDOW PERFORMANCE TESTING WAS PERFORMED AND SUCCESSFULLY PASSED ON 01/27/20.
AutoCAD SHX Text E111
WINDOW PERFORMANCE TESTING WAS PERFORMED ON 01/23/20, WITH TWO FIXED PASSING AIR AND TWO DOUBLE HUNG FAILING AIR. WINDOW PERFORMANCE TESTING WAS PERFORMED AND SUCCESSFULLY PASSED ON 01/27/20.
_J w
:r:
f- ::i U)
C'\I C'\I
3:
z
_J w
:r:
f- ::i U)
C'\I C'\I
C'\I C'\I
I -tj-
U) z
0:::
0:::
u w
0:::
u
U) f-z w
::i u z f-u
::i 0:::
f- U) z u co U) w u 0:::
w
U) w _J f f- _J _J
::i 0...
U) 0...
z m co C'\I
LL
c:o X
'O"" C'\I 0:::
C'\I
LC)
C'\I
I .
m C'\I
S30 S304 S306 m co I
---i---
I I ·so-c:o �
II
I
I") LC) r--
I
'O"" C'\I
SCALE@
8 0 8 16
SCALE OF FEET
LEGEND:
DESIGNED:
JGWA
�mjmll
LMS, CS
TECH. REVIEW:
NAR
DATE:
2008 NEW MASONRY CONSTRUCTION. AREAS NOT SHOWN AS
MASONRY CONSTRUCTION NEED TO COMPLY WITH HISTORIC
MASONRY REQUIREMENTS PER SPECIFICATIONS.
LOCATION OF GROUNDING CABLE FOR
LIGHTNING PROTECTION SYSTEM
SUB SHEET NO. TITLE OF SHEET
ADMINISTRATION BUILDING
SOUTH ELEVATION
NEW
DRAWING NO.
135749
PMIS/PKG NO.
A2.2 2506738 & 238559C
SHEET
PULLMAN NATIONAL MONUMENT
05/04/2020 CHICAGO, ILLINOIS 09 OF 1 6
AutoCAD SHX Text
XII
AutoCAD SHX Text
XI
AutoCAD SHX Text X
AutoCAD SHX Text
IX
AutoCAD SHX Text
VIII
AutoCAD SHX Text
VII
AutoCAD SHX Text
VI
AutoCAD SHX Text V
AutoCAD SHX Text
VI
AutoCAD SHX Text
III
AutoCAD SHX Text
II
AutoCAD SHX Text I
AutoCAD SHX Text N
AutoCAD SHX Text S
AutoCAD SHX Text
SOUTH ELEVATION
AutoCAD SHX Text A2.2
AutoCAD SHX Text
AutoCAD SHX Text
%%U SOUTH ELEVATION
AutoCAD SHX Text A2.2
AutoCAD SHX Text
SCALE
AutoCAD SHX Text A
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
SCALE OF FEET
AutoCAD SHX Text
SCALE
AutoCAD SHX Text A
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
DESIGNED:
AutoCAD SHX Text
TECH. REVIEW:
AutoCAD SHX Text
SUB SHEET NO.
AutoCAD SHX Text
PMIS/PKG NO.
AutoCAD SHX Text
DRAWING NO.
AutoCAD SHX Text
SHEET
AutoCAD SHX Text
OF
AutoCAD SHX Text
TITLE OF SHEET
AutoCAD SHX Text
ADMINISTRATION BUILDING
AutoCAD SHX Text
PULLMAN NATIONAL MONUMENT CHICAGO, ILLINOIS
AutoCAD SHX Text 05/04/2020
AutoCAD SHX Text
NAR
AutoCAD SHX Text
LMS, CS
AutoCAD SHX Text
JGWA
AutoCAD SHX Text 250673B & 238559C
AutoCAD SHX Text
AutoCAD SHX Text 590 135749
AutoCAD SHX Text PROTECT STABILIZED WALL AND ASSOCIATED STRUCTURAL BRACING ADJACENT TO PROJECT SITE, TYPICAL.
AutoCAD SHX Text 5/1/20 R24 X:\18F0269 NPS PULL TITLE III SERVICES\06 - CONSTRUCTION DOCUMENTS\01 CAD\RECORD DRAWINGS 04-2020\A2.2 - SOUTH ELEVATION.DWG A2.2 - SOUTH ELEVATION R24 X:\18F0269 NPS PULL TITLE III SERVICES\06 - CONSTRUCTION DOCUMENTS\01 CAD\RECORD DRAWINGS 04-2020\A2.2 - SOUTH ELEVATION.DWG A2.2 - SOUTH ELEVATIONX:\18F0269 NPS PULL TITLE III SERVICES\06 - CONSTRUCTION DOCUMENTS\01 CAD\RECORD DRAWINGS 04-2020\A2.2 - SOUTH ELEVATION.DWG A2.2 - SOUTH ELEVATION A2.2 - SOUTH ELEVATIONA2.2 - SOUTH ELEVATION
AutoCAD SHX Text S211
AutoCAD SHX Text S210
AutoCAD SHX Text S209
AutoCAD SHX Text S208
AutoCAD SHX Text S207
AutoCAD SHX Text S206
AutoCAD SHX Text S205
AutoCAD SHX Text S204
AutoCAD SHX Text S307
AutoCAD SHX Text S308
AutoCAD SHX Text S304
AutoCAD SHX Text S303
AutoCAD SHX Text S302
AutoCAD SHX Text S305
AutoCAD SHX Text S306
AutoCAD SHX Text S301
AutoCAD SHX Text S300
AutoCAD SHX Text S203
AutoCAD SHX Text S202
AutoCAD SHX Text S101
AutoCAD SHX Text S100
AutoCAD SHX Text S200
AutoCAD SHX Text S201
AutoCAD SHX Text NOTES: 1. REFER TO A3-SERIES SHEETS FOR WINDOW SCOPE OF WORK. REFER TO A3-SERIES SHEETS FOR WINDOW SCOPE OF WORK. 2. NO WORK AT MASONRY, TYPICAL. PROTECT MASONRY SURFACES NO WORK AT MASONRY, TYPICAL. PROTECT MASONRY SURFACES AND ELEMENTS TO REMAIN. 3. REFER TO A1-SERIES SHEETS FOR SNOW GUARD LAYOUT REFER TO A1-SERIES SHEETS FOR SNOW GUARD LAYOUT CONFIGURATIONS. 4. REFER TO SPECIFICATIONS AND SHEETS C1.0, R1.0, AND A1.0 REFER TO SPECIFICATIONS AND SHEETS C1.0, R1.0, AND A1.0 FOR NOTES REGARDING PROTECTION OF ITEMS ADJACENT TO CONSTRUCTION ACTIVITIES. 5. REFER TO SHEET A5.0 FOR ADDITIONAL INFORMATION ABOUT NEW REFER TO SHEET A5.0 FOR ADDITIONAL INFORMATION ABOUT NEW LIGHTNING PROTECTION SYSTEM. 6. CONTRACTOR IS TO MAKE ALL MASONRY REPAIRS NECESSARY CONTRACTOR IS TO MAKE ALL MASONRY REPAIRS NECESSARY FOR THE INSTALLATION OF NEW WINDOWS.
AutoCAD SHX Text 2008 NEW MASONRY CONSTRUCTION. AREAS NOT SHOWN AS NEW MASONRY CONSTRUCTION NEED TO COMPLY WITH HISTORIC MASONRY REQUIREMENTS PER SPECIFICATIONS.
AutoCAD SHX Text
LEGEND:
AutoCAD SHX Text
LOCATION OF GROUNDING CABLE FOR LIGHTNING PROTECTION SYSTEM
AutoCAD SHX Text REFER TO SHEET A1.0 FOR SCOPE OF ROOF REPLACEMENT WORK AT MANSARD AND STEEP SLOPE ROOF AREAS, INCLUSIVE OF DORMER CONSTRUCTION. EXISTING ROOF DRAINAGE SYSTEM TO REMAIN, TYPICAL.
AutoCAD SHX Text
REFER TO SHEET A1.1 FOR SCOPE OF ROOF REPLACEMENT WORK AT TOWER.
AutoCAD SHX Text EXISTING WEATHERVANE ATOP FLAGPOLE. REFER TO SHEET A1.1 FOR SCOPE OF WORK, THIS ELEMENT.
AutoCAD SHX Text LOCATE NEW LIGHTNING PROTECTION GROUNDING CABLE AT FORMER INTERSECTION BETWEEN NON-EXTANT SOUTH FACTORY BAY AND ADMINISTRATION BUILDING, THIS LOCATION. CONCEAL BEHIND NEW DOWNSPOUT.
AutoCAD SHX Text
REFER TO SHEET A4.1 FOR STEEP SLOPE ROOF DETAILS.
AutoCAD SHX Text
REFER TO SHEET A4.0 FOR MANSARD ROOF DETAILS.
AutoCAD SHX Text REMOVE PORTION OF (2) DOWNSPOUTS, THIS ELEVATION, AND REPLACE WITH NEW ROOF LEADERS IN SLOPED HORIZONTAL CONFIGURATION (MIN. PITCH 1/8" PER FOOT). PROVIDE NEW VERTICAL DOWNSPOUT AT WEST LOCATION AS SHOWN.
AutoCAD SHX Text TIE-IN NEW HORIZONTAL ROOF LEADER TO EXISTING DOWNSPOUT AT THIS LOCATION, REFER TO SHEET A2.1 FOR ADDITIONAL INFORMATION.
AutoCAD SHX Text S102
AutoCAD SHX Text
NO WORK AT MASONRY OPENING S102 (FUTURE DOOR).
AutoCAD SHX Text PER PUNCH LIST ITEM 65, DATED 12/23/2019, CONTRACTOR WAS UNABLE TO DOCUMENT HOW THE EXISTING WEATHERVANE WAS RE-SECURED TO THE TOP OF THE FLAGPOLE AND HOW THE REPAIRS WERE CARRIED OUT. NO REFINISHING WORK OF FLAGPOLE OR WEATHERVANE WAS COMPLETED. PER MEETING MINUTES, DATED 10/17/19, NPS ACTING SUPERINTENDENT STATED THAT AN AGREEMENT WILL BE REACHED BETWEEN NPS AND CONTRACTOR IF SOMETHING FAILS IN THE FUTURE.
AutoCAD SHX Text
WINDOW
AutoCAD SHX Text
WINDOW PERFORMANCE TESTING RESULTS
AutoCAD SHX Text S207
AutoCAD SHX Text WINDOW PERFORMANCE TESTING WAS PERFORMED ON AND WAS SUCCESSFULLY PASSED ON 01/13/20.
AutoCAD SHX Text S210
AutoCAD SHX Text WINDOW PERFORMANCE TESTING WAS PERFORMED ON AND WAS SUCCESSFULLY PASSED ON 01/27/20.
AutoCAD SHX Text S211
AutoCAD SHX Text WINDOW PERFORMANCE TESTING WAS PERFORMED ON AND WAS SUCCESSFULLY PASSED ON 12/13/19.
AutoCAD SHX Text THESE RECORD DRAWINGS HAVE BEEN PRODUCED BY JOHN G. WAITE ASSOCIATES, ARCHITECTS IN MAY OF 2020, IN AN EFFORT TO IDENTIFY WHERE THE WORK COMPLETED BY THE CONTRACTOR DIFFERS FROM THE CONTRACT DOCUMENTS. INFORMATION PROVIDED ON THESE RECORD DRAWINGS HAS BEEN SOURCED FROM PROJECT RECORDS OBTAINED FROM THE CONTRACTOR, THE ARCHITECT, AND THE NATIONAL PARK SERVICE.
AutoCAD SHX Text
AutoCAD SHX Text PER RFI 25, DATED 07/18/2019, AND RFP 2, DATED 08/02/2019, ALL EXTERIOR ALUMINUM STORM WINDOWS WERE FABRICATED AND FURNISHED, BUT NOT INSTALLED. THEY WERE PUT INTO STORAGE ON THE SECOND FLOOR UPON RECEIPT / ACCEPTANCE BY NPS.
XII
AutoCAD SHX Text
XI
AutoCAD SHX Text X
AutoCAD SHX Text
IX
AutoCAD SHX Text
VIII
AutoCAD SHX Text
VII
AutoCAD SHX Text
VI
AutoCAD SHX Text V
AutoCAD SHX Text
VI
AutoCAD SHX Text
III
AutoCAD SHX Text
II
AutoCAD SHX Text I
AutoCAD SHX Text N
AutoCAD SHX Text S
AutoCAD SHX Text
NORTH ELEVATION
AutoCAD SHX Text A2.3
AutoCAD SHX Text
AutoCAD SHX Text
%%U NORTH ELEVATION
AutoCAD SHX Text A2.3
AutoCAD SHX Text
SCALE
AutoCAD SHX Text A
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
SCALE OF FEET
AutoCAD SHX Text
SCALE
AutoCAD SHX Text A
AutoCAD SHX Text N200
AutoCAD SHX Text N205
AutoCAD SHX Text N206
AutoCAD SHX Text N203
AutoCAD SHX Text N204
AutoCAD SHX Text N202
AutoCAD SHX Text N201
AutoCAD SHX Text N207
AutoCAD SHX Text N208
AutoCAD SHX Text N210
AutoCAD SHX Text N209
AutoCAD SHX Text N100
AutoCAD SHX Text N101
AutoCAD SHX Text N306
AutoCAD SHX Text N304
AutoCAD SHX Text N305
AutoCAD SHX Text N303
AutoCAD SHX Text N302
AutoCAD SHX Text N301
AutoCAD SHX Text N300
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
DESIGNED:
AutoCAD SHX Text
TECH. REVIEW:
AutoCAD SHX Text
SUB SHEET NO.
AutoCAD SHX Text
PMIS/PKG NO.
AutoCAD SHX Text
DRAWING NO.
AutoCAD SHX Text
SHEET
AutoCAD SHX Text
OF
AutoCAD SHX Text
TITLE OF SHEET
AutoCAD SHX Text
ADMINISTRATION BUILDING
AutoCAD SHX Text
PULLMAN NATIONAL MONUMENT CHICAGO, ILLINOIS
AutoCAD SHX Text 05/04/2020
AutoCAD SHX Text
NAR
AutoCAD SHX Text
LMS, CS
AutoCAD SHX Text
JGWA
AutoCAD SHX Text 250673B & 238559C
AutoCAD SHX Text
AutoCAD SHX Text 590 135749
AutoCAD SHX Text N307
AutoCAD SHX Text N308
AutoCAD SHX Text EXISTING WEATHERVANE ATOP FLAGPOLE. REFER TO SHEET A1.1 FOR SCOPE OF WORK, THIS ELEMENT.
AutoCAD SHX Text 5/1/20 R24 X:\18F0269 NPS PULL TITLE III SERVICES\06 - CONSTRUCTION DOCUMENTS\01 CAD\RECORD DRAWINGS 04-2020\A2.3 - NORTH ELEVATION.DWG A2.3 - NORTH ELEVATION R24 X:\18F0269 NPS PULL TITLE III SERVICES\06 - CONSTRUCTION DOCUMENTS\01 CAD\RECORD DRAWINGS 04-2020\A2.3 - NORTH ELEVATION.DWG A2.3 - NORTH ELEVATIONX:\18F0269 NPS PULL TITLE III SERVICES\06 - CONSTRUCTION DOCUMENTS\01 CAD\RECORD DRAWINGS 04-2020\A2.3 - NORTH ELEVATION.DWG A2.3 - NORTH ELEVATION A2.3 - NORTH ELEVATIONA2.3 - NORTH ELEVATION
AutoCAD SHX Text NOTES: 1. REFER TO A3-SERIES SHEETS FOR WINDOW SCOPE OF WORK. REFER TO A3-SERIES SHEETS FOR WINDOW SCOPE OF WORK. 2. NO WORK AT MASONRY, TYPICAL. PROTECT MASONRY SURFACES NO WORK AT MASONRY, TYPICAL. PROTECT MASONRY SURFACES AND ELEMENTS TO REMAIN. 3. REFER TO A1-SERIES SHEETS FOR SNOW GUARD LAYOUT REFER TO A1-SERIES SHEETS FOR SNOW GUARD LAYOUT CONFIGURATIONS. 4. REFER TO SPECIFICATIONS AND SHEETS C1.0, R1.0, AND A1.0 REFER TO SPECIFICATIONS AND SHEETS C1.0, R1.0, AND A1.0 FOR NOTES REGARDING PROTECTION OF ITEMS ADJACENT TO CONSTRUCTION ACTIVITIES. 5. REFER TO SHEET A5.0 FOR ADDITIONAL INFORMATION ABOUT NEW REFER TO SHEET A5.0 FOR ADDITIONAL INFORMATION ABOUT NEW LIGHTNING PROTECTION SYSTEM. 6. CONTRACTOR IS TO MAKE ALL MASONRY REPAIRS NECESSARY CONTRACTOR IS TO MAKE ALL MASONRY REPAIRS NECESSARY FOR THE INSTALLATION OF NEW WINDOWS.
AutoCAD SHX Text 2008 NEW MASONRY CONSTRUCTION. AREAS NOT SHOWN AS NEW MASONRY CONSTRUCTION NEED TO COMPLY WITH HISTORIC MASONRY REQUIREMENTS PER SPECIFICATIONS.
AutoCAD SHX Text
LEGEND:
AutoCAD SHX Text
LOCATION OF GROUNDING CABLE FOR LIGHTNING PROTECTION SYSTEM
AutoCAD SHX Text REFER TO SHEET A1.0 FOR SCOPE OF ROOF REPLACEMENT WORK AT MANSARD AND STEEP SLOPE ROOF AREAS, INCLUSIVE OF DORMER CONSTRUCTION. EXISTING ROOF DRAINAGE SYSTEM TO REMAIN, TYPICAL.
AutoCAD SHX Text
REFER TO SHEET A1.1 FOR SCOPE OF ROOF REPLACEMENT WORK AT TOWER.
AutoCAD SHX Text
REFER TO SHEET A4.1 FOR STEEP SLOPE ROOF DETAILS.
AutoCAD SHX Text
REFER TO SHEET A4.0 FOR MANSARD ROOF DETAILS.
AutoCAD SHX Text NO INTERIOR ACCESS TO NORTH FACTORY BAY. REFER TO SHEET C1.0 NOTE 8 FOR INFORMATION ABOUT PLYWOOD SHEATHED CONSTRUCTION AND DOOR REQUIRED AT EXISTING MASONRY OPENING, THIS LOCATION.
AutoCAD SHX Text LOCATE NEW LIGHTNING PROTECTION GROUNDING CABLE AT INTERSECTION BETWEEN NORTH FACTORY BAY AND ADMINISTRATION BUILDING, THIS LOCATION. FASTEN CABLE TO ADMINISTRATION BUILDING ONLY.
AutoCAD SHX Text
EXISTING DOWNSPOUTS TO BE MAINTAINED, TYP.
AutoCAD SHX Text THESE RECORD DRAWINGS HAVE BEEN PRODUCED BY JOHN G. WAITE ASSOCIATES, ARCHITECTS IN MAY OF 2020, IN AN EFFORT TO IDENTIFY WHERE THE WORK COMPLETED BY THE CONTRACTOR DIFFERS FROM THE CONTRACT DOCUMENTS. INFORMATION PROVIDED ON THESE RECORD DRAWINGS HAS BEEN SOURCED FROM PROJECT RECORDS OBTAINED FROM THE CONTRACTOR, THE ARCHITECT, AND THE NATIONAL PARK SERVICE.
AutoCAD SHX Text
AutoCAD SHX Text PER RFI 25, DATED 07/18/2019, AND RFP 2, DATED 08/02/2019, ALL EXTERIOR ALUMINUM STORM WINDOWS WERE FABRICATED AND FURNISHED, BUT NOT INSTALLED. THEY WERE PUT INTO STORAGE ON THE SECOND FLOOR UPON RECEIPT / ACCEPTANCE BY NPS.
AutoCAD SHX Text
AutoCAD SHX Text PER PUNCH LIST ITEM 65, DATED 12/23/2019, CONTRACTOR WAS UNABLE TO DOCUMENT HOW THE EXISTING WEATHERVANE WAS RE-SECURED TO THE TOP OF THE FLAGPOLE AND HOW THE REPAIRS WERE CARRIED OUT. NO REFINISHING WORK OF FLAGPOLE OR WEATHERVANE WAS COMPLETED. PER MEETING MINUTES, DATED 10/17/19, NPS ACTING SUPERINTENDENT STATED THAT AN AGREEMENT WILL BE REACHED BETWEEN NPS AND CONTRACTOR IF SOMETHING FAILS IN THE FUTURE.
NO.
TYPE
SCOPE
MASONRY OPENING
INT. STORM NOT USED WINDOW RESTORATION ACTIONS OTHER NOTES NO.
WIDTH HEIGHT
WEST ELEVATION
W100 1 RESTORE 4'-6" 14'-0" TYPE 1 W100
W101 2 RESTORE 6'-0" 14'-0" TYPE 2 W101
W102 1 RESTORE 4'-6" 14'-0" TYPE 1 W102
W103 6 RESTORE 3'-0" 8'-0" TYPE 3 W103
W104 N/A NOT IN SCOPE
NEW DOOR BY OTHERS
W104
W105 6 RESTORE 3'-0" 8'-0" TYPE 3 W105
W106 1 RESTORE 4'-6" 14'-0" TYPE 1 W106
W107 2 RESTORE 6'-0" 14'-0" TYPE 2 W107
W108 1 RESTORE 4'-6" 14'-0" TYPE 1 W108
W200 3 RESTORE 4'-6" 11'-11" W200
W201 4 RESTORE 6'-0" 12'-8" W201
W202 3 RESTORE 4'-6" 11'-11" W202
W203 7 RESTORE 5'-0" 11'-8" W203
W204 12 RESTORE 3'-6" 9'-8" W204
W205 12 RESTORE 3'-6" 9'-8" W205
W206 7 RESTORE 5'-0" 11'-8" W206
W207 3 RESTORE 4'-6" 11'-11" W207
W208 4 RESTORE 6'-0" 12'-8" W208
W209 3 RESTORE 4'-6" 11'-11" W209
W300 5 RESTORE 7'-3" 2'-4" W300
W301 5 RESTORE 7'-3" 2'-4" W301
W302 8 RESTORE 5'-0" 8'-10"
REPL. (1) GLASS LITE
W302
W303 11 RESTORE 3'-6" 9'-8" W303
W304 11 RESTORE 3'-6" 9'-8" W304
W305 8 RESTORE 5'-0" 8'-10" W305
W306 5 RESTORE 7'-3" 2'-4" W306
W307 5 RESTORE 7'-3" 2'-4" W307
W500 10 RESTORE 7'-6" 3'-9" W500
W600 9 RESTORE 1'-0" 4'-0" W600
W601 9 RESTORE 1'-0" 4'-0" W601
W602 9 RESTORE 1'-0" 4'-0" W602
E100 23 NEW 3'-5" 13'-0"
D. H. W/ FIXED TRANSOM
E100
E101 24 NEW 5'-6" 13'-0"
D. H. W/ FIXED TRANSOM
E101
E102 23 NEW 3'-5" 13'-0"
D. H. W/ FIXED TRANSOM
E102
E103 23 NEW 3'-5" 13'-0"
D. H. W/ FIXED TRANSOM
E103
E104 24 NEW 5'-6" 13'-0"
D. H. W/ FIXED TRANSOM
E104
E105 23 NEW 3'-5" 16'-9"
D. H. W/ FIXED TRANSOM
E105
E106 N/A NOT IN SCOPE
NEW DOOR BY OTHERS
E106
E107 23 NEW 3'-5" 13'-0"
D. H. W/ FIXED TRANSOM
E107
E108 24 NEW 5'-6" 16'-9"
D. H. W/ FIXED TRANSOM
E108
E109 23 NEW 3'-5" 13'-0"
D. H. W/ FIXED TRANSOM
E109
E110 23 NEW 3'-5" 13'-0"
D. H. W/ FIXED TRANSOM
E110
E111 24 NEW 5'-6" 13'-0"
D. H. W/ FIXED TRANSOM
E111
E112 N/A NOT IN SCOPE
NEW DOOR BY OTHERS
E112
E200 20A NEW 3'-5" 10'-8"
DOUBLE-HUNG
E200
E201 20B NEW 5'-6" 11'-3"
DOUBLE-HUNG
E201
E202 20C NEW 3'-5" 10'-8"
DOUBLE-HUNG
E202
E203 20A NEW 3'-5" 10'-8"
DOUBLE-HUNG
E203
E204 20B NEW 5'-6" 11'-3"
DOUBLE-HUNG
E204
E205 20C NEW 3'-5" 10'-8"
DOUBLE-HUNG
E205
E206 21 NEW 5'-3" 10'-3"
D. H. W/ FIXED TRANSOM
E206
E207 21 NEW 5'-3" 10'-3"
D. H. W/ FIXED TRANSOM
E207
E208 20A NEW 3'-5" 10'-8"
DOUBLE-HUNG
E208
E209 20B NEW 5'-6" 11'-3"
DOUBLE-HUNG
E209
E210 20C NEW 3'-5" 10'-8"
DOUBLE-HUNG
E210
E211 20A NEW 3'-5" 10'-8"
DOUBLE-HUNG
E211
E212 20B NEW 5'-6" 11'-3"
DOUBLE-HUNG
E212
E213 20C NEW 3'-5" 10'-8"
DOUBLE-HUNG
E213
E300 18 RESTORE 4'-6" 7'-2"
REPL. (4) GLASS LITES
E300
E301 18 RESTORE 4'-6" 7'-2"
REPL. (1) GLASS LITE
E301
E302 18 RESTORE 4'-6" 7'-2"
REPL. (2) GLASS LITES
E302
E303 22 NEW 5'-3" 6'-11"
FIXED SASH
E303
E304 22 NEW 5'-3" 6'-11"
FIXED SASH
E304
E305 18 RESTORE 4'-6" 7'-2"
REPL. (12) GLASS LITES
E305
E306 18 RESTORE 4'-6" 7'-2"
REPL. (6) GLASS LITES
E306
E307 18 RESTORE 4'-6" 7'-2"
REPL. (4) GLASS LITES
E307
E600 9 RESTORE 1'-0" 4'-0" E600
E601 9 RESTORE 1'-0" 4'-0" E601
E602 9 RESTORE 1'-0" 4'-0" E602
NO.
TYPE
SCOPE
MASONRY OPENING
INT. STORM NOT USED WINDOW RESTORATION ACTIONS OTHER NOTES NO.
WIDTH HEIGHT
NORTH ELEVATION
N100 13 RESTORE 3'-2" 14'-2" TYPE 4 N100
N101 13 RESTORE 3'-2" 14'-2" TYPE 4
REPL. (1) GLASS LITE
N101
N200 19 NEW 4'-0" 5'-10" DOUBLE-HUNG N200
N201 19 NEW 4'-0" 5'-10" DOUBLE-HUNG N201
N202 19 NEW 4'-0" 5'-10" DOUBLE-HUNG N202
N203 19 NEW 4'-0" 5'-10" DOUBLE-HUNG N203
N204 19 NEW 4'-0" 5'-10" DOUBLE-HUNG N204
N205 19 NEW 4'-0" 5'-10" DOUBLE-HUNG N205
N206 19 NEW 4'-0" 5'-10" DOUBLE-HUNG N206
N207 16 RESTORE 3'-2" 6'-6" N207
N208 16 RESTORE 3'-2" 6'-6" N208
N209 14 RESTORE 3'-2" 12'-1" N209
N210 14 RESTORE 3'-2" 12'-1" N210
N300 17 RESTORE 3'-4" 7'-2" N300
N301 17 RESTORE 3'-4" 7'-2" N301
N302 18 RESTORE 4'-6" 7'-2"
REPL. (1) GLASS LITE
N302
N303 18 RESTORE 4'-6" 7'-2"
REPL. (8) GLASS LITES
N303
N304 18 RESTORE 4'-6" 7'-2" N304
N305 18 RESTORE 4'-6" 7'-2"
REPL. (2) GLASS LITES
N305
N306 18 RESTORE 4'-6" 7'-2"
REPL. (2) GLASS LITES
N306
N307 15 RESTORE 2'-6" 6'-7" N307
N308 15 RESTORE 2'-6" 6'-7" N308
SOUTH ELEVATION
S100 13 RESTORE 3'-2" 14'-2" TYPE 4 S100
S101 13 RESTORE 3'-2" 14'-2" TYPE 4 S101
S102 N/A NOT IN SCOPE
NEW DOOR BY OTHERS
S102
S200 14 RESTORE 3'-2" 12'-1" S200
S201 14 RESTORE 3'-2" 12'-1" S201
S202 16 RESTORE 3'-2" 6'-6" S202
S203 16 RESTORE 3'-2" 6'-6" S203
S204 19 NEW 4'-0" 5'-10"
DOUBLE-HUNG
S204
S205 19 NEW 4'-0" 5'-10"
DOUBLE-HUNG
S205
S206 19 NEW 4'-0" 5'-10"
DOUBLE-HUNG
S206
S207 19 NEW 4'-0" 5'-10"
DOUBLE-HUNG
S207
S208 19 NEW 4'-0" 5'-10"
DOUBLE-HUNG
S208
S209 19 NEW 4'-0" 5'-10"
DOUBLE-HUNG
S209
S211 19 NEW 4'-0" 5'-10"
DOUBLE-HUNG
S211
S300 15 RESTORE 2'-6" 6'-7" S300
S301 15 RESTORE 2'-6" 6'-7" S301
S302 18 RESTORE 4'-6" 7'-2" S302
S303 18 RESTORE 4'-6" 7'-2" S303
S304 18 RESTORE 4'-6" 7'-2"
REPL. (4) GLASS LITES
S304
S305 18 RESTORE 4'-6" 7'-2" S305
S306 18 RESTORE 4'-6" 7'-2" S306
S307 17 RESTORE 3'-4" 7'-2" S307
S308 17 RESTORE 3'-4" 7'-2"
RESECURE INT. STOP
S308
AutoCAD SHX Text
WINDOW SCHEDULE
AutoCAD SHX Text A3.0
AutoCAD SHX Text
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
DESIGNED:
AutoCAD SHX Text
TECH. REVIEW:
AutoCAD SHX Text
SUB SHEET NO.
AutoCAD SHX Text
PMIS/PKG NO.
AutoCAD SHX Text
DRAWING NO.
AutoCAD SHX Text
SHEET
AutoCAD SHX Text
OF
AutoCAD SHX Text
TITLE OF SHEET
AutoCAD SHX Text
ADMINISTRATION BUILDING
AutoCAD SHX Text
PULLMAN NATIONAL MONUMENT CHICAGO, ILLINOIS
AutoCAD SHX Text 05/04/2020
AutoCAD SHX Text
NAR
AutoCAD SHX Text
LMS, CS
AutoCAD SHX Text
JGWA
AutoCAD SHX Text 250673B & 238559C
AutoCAD SHX Text
AutoCAD SHX Text 590 135749
AutoCAD SHX Text 5/1/20 R24 X:\18F0269 NPS PULL TITLE III SERVICES\06 - CONSTRUCTION DOCUMENTS\01 CAD\RECORD DRAWINGS 04-2020\A3.0 - WINDOW SCHEDULE.DWG A3.0 - WINDOW SCHEDULE R24 X:\18F0269 NPS PULL TITLE III SERVICES\06 - CONSTRUCTION DOCUMENTS\01 CAD\RECORD DRAWINGS 04-2020\A3.0 - WINDOW SCHEDULE.DWG A3.0 - WINDOW SCHEDULEX:\18F0269 NPS PULL TITLE III SERVICES\06 - CONSTRUCTION DOCUMENTS\01 CAD\RECORD DRAWINGS 04-2020\A3.0 - WINDOW SCHEDULE.DWG A3.0 - WINDOW SCHEDULE A3.0 - WINDOW SCHEDULEA3.0 - WINDOW SCHEDULE
AutoCAD SHX Text NOTES: 1. REFER TO DRAWING A3.1 FOR WINDOW TYPES AND DRAWING A3.2 FOR WINDOW DETAILS. EXISTING WINDOWS ARE WOOD; NEW WINDOWS TO BE ALUMINUM. REFER TO DRAWING A3.1 FOR WINDOW TYPES AND DRAWING A3.2 FOR WINDOW DETAILS. EXISTING WINDOWS ARE WOOD; NEW WINDOWS TO BE ALUMINUM. 2. EXISTING WOOD WINDOWS (RESTORE): PROVIDE MINOR WOOD PUTTY REPAIRS AT EXTERIOR SILLS, LOWER 12" OF EXTERIOR FRAME/TRIM, AND EXTERIOR MUNTINS. EXISTING WOOD WINDOWS (RESTORE): PROVIDE MINOR WOOD PUTTY REPAIRS AT EXTERIOR SILLS, LOWER 12" OF EXTERIOR FRAME/TRIM, AND EXTERIOR MUNTINS. WHERE INDICATED ON SCHEDULE, REPLACE EXISTING LAMINATED GLASS THAT IS EITHER BROKEN OR SHOWS EVIDENCE OF DELAMINATION; COLOR, THICKNESS, AND INSTALLATION DETAILS TO MATCH EXISTING. QUANTITIES AND LOCATIONS OF GLASS FOR REPLACEMENT ARE SCHEDULED FOR THE CONVENIENCE OF THE CONTRACTOR. PREPARE, PRIME, AND PAINT EXTERIOR SURFACES (EXTERIOR FRAME AND TRIM ELEMENTS CUSTOM COLOR 1 - PULLMAN GREEN, EXTERIOR SASH CUSTOM COLOR 2 - PULLMAN RED). PREPARE, STAIN, AND VARNISH INTERIOR SASH AND FRAME SURFACES. CLEAN AND RECONDITION EXISTING OPERATIONAL HARDWARE TO ENSURE PROPER FUNCTIONALITY OF WINDOWS. 3. AT MASONRY OPENINGS SCHEDULED TO RECEIVE NEW WINDOWS, REMOVE EXISTING WOOD INFILL FRAMING, EXTERIOR PLYWOOD, AND ASSOCIATED FASTENERS AND AT MASONRY OPENINGS SCHEDULED TO RECEIVE NEW WINDOWS, REMOVE EXISTING WOOD INFILL FRAMING, EXTERIOR PLYWOOD, AND ASSOCIATED FASTENERS AND SEALANT. CLEAN, RESET, AND REPOINT ANY UNSTABLE MASONRY PRIOR TO INSTALLATION OF NEW SOLID WOOD BLOCKING FOR NEW ALUMINUM WINDOWS. 4. ALUMINUM WINDOWS (NEW): PROVIDE CUSTOM-FABRICATED, THERMALLY-BROKEN ALUMINUM WINDOWS (SASH, FRAME, AND EXTERIOR TRIM) WITH 1/2" THICK ALUMINUM WINDOWS (NEW): PROVIDE CUSTOM-FABRICATED, THERMALLY-BROKEN ALUMINUM WINDOWS (SASH, FRAME, AND EXTERIOR TRIM) WITH 1/2" THICK LOW-E ARGON-FILLED INSULATED GLASS IN TRUE DIVIDED-LITE CONFIGURATIONS AS SHOWN FOR EACH WINDOW TYPE. REFER TO SCHEDULE AND SHEET A3.1 FOR INFORMATION ABOUT OPERABILITY; MAINTAIN FRAME AND SASH DIMENSIONS AND HORIZONTAL SHADOW LINES OF EXISTING WOOD WINDOWS. PROVIDE CUSTOM EXTERIOR EXTRUDED ALUMINUM TRIM PROFILE AS INDICATED ON SHEET A3.2 AND CUSTOM 2-COLOR EXTERIOR PAINT SCHEME TO MATCH EXISTING WOOD WINDOWS; PROVIDE SHOP-PRIMED FINISH AT INTERIOR. PROVIDE MANUFACTURER'S STANDARD OPERATIONAL HARDWARE FOR WINDOW FUNCTION AS SCHEDULED. 5. WHERE INDICATED ON SCHEDULE, PROVIDE NEW EXTERIOR FIXED ALUMINUM STORM MULTI-PANEL WINDOWS WITH 1/8" THICK TEMPERED GLASS WITH LOW-E WHERE INDICATED ON SCHEDULE, PROVIDE NEW EXTERIOR FIXED ALUMINUM STORM MULTI-PANEL WINDOWS WITH 1/8" THICK TEMPERED GLASS WITH LOW-E COATING ON INTERIOR SURFACE AFTER COMPLETION OF EXTERIOR WOOD WINDOW PREPARATION/PAINTING AND SEALANT INSTALLATION. PROVIDE CUSTOM COLOR FOR EXTERIOR STORM PANELS TO MATCH CUSTOM COLOR 1 - PULLMAN GREEN. 6. REMOVE AND REPLACE PERIMETER SEALANT AT ALL MASONRY OPENINGS. REMOVE AND REPLACE PERIMETER SEALANT AT ALL MASONRY OPENINGS. 7. CONTRACTOR TO VERIFY DIMENSIONS OF EACH MASONRY OPENING.CONTRACTOR TO VERIFY DIMENSIONS OF EACH MASONRY OPENING.
AutoCAD SHX Text THESE RECORD DRAWINGS HAVE BEEN PRODUCED BY JOHN G. WAITE ASSOCIATES, ARCHITECTS IN MAY OF 2020, IN AN EFFORT TO IDENTIFY WHERE THE WORK COMPLETED BY THE CONTRACTOR DIFFERS FROM THE CONTRACT DOCUMENTS. INFORMATION PROVIDED ON THESE RECORD DRAWINGS HAS BEEN SOURCED FROM PROJECT RECORDS OBTAINED FROM THE CONTRACTOR, THE ARCHITECT, AND THE NATIONAL PARK SERVICE.
AutoCAD SHX Text
AutoCAD SHX Text PER RFI 25, DATED 07/18/2019, AND RFP 2, DATED 08/02/2019, ALL EXTERIOR ALUMINUM STORM WINDOWS WERE FABRICATED AND FURNISHED, BUT NOT INSTALLED. THEY WERE PUT INTO STORAGE ON THE SECOND FLOOR UPON RECEIPT/ACCEPTANCE BY NPS.
AutoCAD SHX Text
AutoCAD SHX Text PER RFI 28, DATED 08/13/2019, ADDITIONAL BROKEN GLASS LITES, EXCEEDING THE 48 LITE ALLOWANCE FOR EXISTING WOOD WINDOWS, WERE NOT SELECTED FOR REPLACEMENT AT THIS TIME.
AutoCAD SHX Text
AutoCAD SHX Text
PER RFI 28, DATED 08/13/2019, THESE GLASS LITES WERE NOT REPLACED.
AutoCAD SHX Text
AutoCAD SHX Text
PER RFI 28, DATED 08/13/2019, THESE GLASS LITES WERE NOT REPLACED.
AutoCAD SHX Text
AutoCAD SHX Text PER RFI 14, DATED 05/02/2019, WHERE INSULATED GLASS LITES ARE SMALLER THAN 14"X14", CONTRACTOR PROVIDED AIR-FILLED LITES IN LIEU OF SPECIFIED ARGON-FILLED LITES AT NEW ALUMINUM WINDOWS. PER RFP 5, DATED 09/04/2019, ALL 41 NEW ALUMINUM WINDOWS WERE FABRICATED WITH SUNGUARD SUPERNEUTRAL ULTRACLEAR LOW-E COATING FOR 69% VISIBLE LIGHT TRANSMITTANCE, PER ILLINOIS SHPO REQUEST.
AutoCAD SHX Text
AutoCAD SHX Text
REPL. GLASS LITE(S), PER 28, DATED 08/13/19.
AutoCAD SHX Text
REPL. GLASS LITE(S), PER 28, DATED 08/13/19.
AutoCAD SHX Text
REPL. GLASS LITE(S), PER 28, DATED 08/13/19.
AutoCAD SHX Text
AutoCAD SHX Text
REPL. GLASS LITE(S), PER 28, DATED 08/13/19.
AutoCAD SHX Text
AutoCAD SHX Text REPL. GLASS LITE(S), PER 28, DATED 08/13/19. REPL. GLASS LITE(S), PER 28, DATED 08/13/19.
AutoCAD SHX Text
AutoCAD SHX Text REPL. GLASS LITE(S), PER 28, DATED 08/13/19. REPL. GLASS LITE(S), PER 28, DATED 08/13/19.
AutoCAD SHX Text
AutoCAD SHX Text REPL. GLASS LITE(S), PER 28, DATED 08/13/19. REPL. GLASS LITE(S), PER 28, DATED 08/13/19. REPL. GLASS LITE(S), PER 28, DATED 08/13/19.
AutoCAD SHX Text
AutoCAD SHX Text
REPL. GLASS LITE(S), PER 28, DATED 08/13/19.
AutoCAD SHX Text
AutoCAD SHX Text
REPL. GLASS LITE(S), PER 28, DATED 08/13/19.
AutoCAD SHX Text
AutoCAD SHX Text PER RFI 25, DATED 07/18/2019, AND RFP 2, DATED 08/02/2019, ALL EXTERIOR ALUMINUM STORM WINDOWS WERE FABRICATED AND FURNISHED, BUT NOT INSTALLED. THEY WERE PUT INTO STORAGE ON THE SECOND FLOOR UPON RECEIPT/ACCEPTANCE BY NPS.
AutoCAD SHX Text PER RFI 25, DATED 07/18/2019, AND RFP 2, DATED 08/02/2019, ALL EXTERIOR ALUMINUM STORM WINDOWS WERE FABRICATED AND FURNISHED, BUT NOT INSTALLED. THEY WERE PUT INTO STORAGE ON THE SECOND FLOOR UPON RECEIPT/ACCEPTANCE BY NPS.
File details come from the government source that posted it. Updated .