B-2 TLX QALI.pdf

PDF 946 KB Posted

Attached to
B-2 TLX Kits Federal contract opportunity
Solicitation number
FA821321R3042
Issued by
Department of the Air Force Materiel Command Lifecycle Management Center Hill Air Force Base

About this file

This document contains a quality assurance letter of instruction and a related federal contract opportunity solicitation. The quality assurance letter outlines inspection requirements for various TLX kits to be procured under contract number 51-50092, awarded on an unspecified date for the B-2 TLX program. Inspections will include explosive weight verification, x-ray and radiographic film review, lot acceptance testing, sample selection, preparation for shipment verification, and documentation reviews. The federal contract opportunity solicitation seeks bids for various TLX kits with quantities ranging from three to six units per national stock number and part number under solicitation FA821321R3042. The sole source buyer is Universal Propulsion Company with cage code 17610. Delivery is required to support the B-2 weapon system.

View the file

Other files for this federal contract opportunity

Other files attached to B-2 TLX Kits, newest first.
File Type Posted
Amend_FA821321R3042_0003.pdf PDF
Amend_FA821321R3042_0002.pdf PDF
Amend_FA821321R3042_0001.pdf PDF
SPI F01-461-5481.pdf PDF
807-Combined 30 Mar 2021.pdf PDF
ID-Combined_30 Mar 2021.pdf PDF
DD Form 1653.pdf PDF
CADPAD Item Marking Instruction.pdf PDF
AIR SPEC 30 Mar 2021.pdf PDF
Solicitation_FA821321R3042.pdf PDF
SPI F01-499-8853.pdf PDF
SPI F01-254-8612.pdf PDF
Form 158 FD2020-21-50092.pdf PDF
EDL-Combined.pdf PDF
ES7034 (Attachment 5).pdf PDF
SPI F01-454-8835.pdf PDF
ADC SOW.pdf PDF
SPI F01-461-5515.pdf PDF
TransInstruction11.pdf PDF
REPSHIP.pdf PDF
Packaging SOW.pdf PDF
Engineer Notes Clarification.pdf PDF
EDL_1377014618074.pdf PDF
Bid Sets.pdf PDF
Show all 24

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Contractor Name

CAGE code

PR No. FD2020-

Date Contract Awarded

Final Delivery Date (FDD)

Program Name

DODIC

Part Number

The contractor, at a minimum, shall allow DCMA to inspect the following points:

Mandatory - M: Stamp and/ or Signature on original documentation (i.e., Mfg. Planning, ATP, FAT Report, etc.)

Witness - W: GSI required to attend per comment section.

Verification - V: Stamp and/or Signature required unless noted otherwise (may be done by written verification) Monitor - R: Will monitor testing, may reduce to verification per comment section.

Notify - N: By phone or email prior to action.

Additional requirements: (DCMA reserves the right to impose additional inspection points as deemed necessary.)

Prepared by:

Date

THIS PLANNING SHEET WILL BE UPDATED IF NECESSARY.

QUALITY ASSURANCE LETTER OF INSTRUCTION

Planning Requirements

COMMENTS

NOTICE

Engineer Signature

Rev Date: 5 May 2019

NSN P/N DODIC

1377-01-499-8853ES 200210068-10 JL04

1377-01-461-5486ES 52170-086 WA43

1377-01-461-5520ES 52170-027 WA09

1377-01-461-5529ES 52171-024 WA13

1377-01-461-5530ES 52171-021 WA11

1377-01-461-5538ES 52170-091 WA17

1377-01-461-6040ES 52171-007 WA30

1377-01-461-6043ES 52170-001 WA34

1377-01-461-8064ES 52170-075 WA63

1377-01-461-8066ES 52170-074 WA62

1377-01-461-8069ES 52170-044 WA65

1377-01-461-8074ES 52170-048 WA53

1377-01-461-8082ES 52170-072 WA60

1377-01-461-8304ES 52170-080 WA78

1377-01-462-2328ES 52170-070 WA82

1377-01-463-0549ES 52171-094 WA85

Sheet1
Blank Page
Book1.pdf
Sheet1
Text46: 12Jun2020
2020-06-12T14:15:34-0600
JOHNSON.AVERY.STEVEN.1457505112
undefined_8: N
Text31: 8. Additional Requirements
undefined_7: M
Text30: 7. Shippers (DD250, Reports)
undefined_6: M
Text29: 6. AMMO Data Card Review
undefined_5: V
Text28: 5. Preparation for Shipment
undefined_4: W
Text27: 4. LAT
undefined_3: V
Text26: 3. LAT Sample Selection
undefined_2: V
Text25: 2. X-Ray/N-Ray
undefined: V
Text36: 1. Explosive Weight

2. Ensure film labeling correct. Ensure radiographic film is readable and well-defined. DCMA is not required to interpret film.

3. Randomly select LAT units per latest government approved ATP.

4. Testing should occur in accordance with latest government approved ATP. Prior to LAT ensure proper calibration and validation of all test equipment. Witness proper test setup and at least the first 3 functional tests. Further witnessing may be required if there are known concerns with the item or requested by Government Engineer.

5. Ensure Paperwork is correct.

6. Verify all energetic materials: list original manufacturer,original lot number, and latest certification/recertification date < 24 months.

7. Ensure Paperwork is correct. Verify Packaging, Packing, Preservation & Marking (PPP&M)

8. Any additional requirements imposed by DCMA shall be approved by Government Project Engineer

Text24: 1.Inspection
Part Number: VARIOUS (See attached list)
DODIC: VARIOUS (See attached list)
Text20: 17610
Text19: Collins
Part Number Line 2:
Contract No: 51-50092
Date Contract Awarded:
Final Delivery Date FDD:
Program Name: B-2 TLX Lines

File details come from the government source that posted it. Updated .