This document provides a consolidated list of references for the solicitation to perform dock side repairs on USCGC JAMES (WMSL-754) in fiscal year 2024. The solicitation seeks repairs and maintenance involving ship structures, auxiliary machinery systems, fire prevention and response, electrical systems, coatings and preservation. The list of references includes Coast Guard technical drawings, publications and standard specifications, as well as other government documents and commercial standards, to ensure all work meets the agency's requirements. Products and services referenced include welding and fabrication, electrical cable testing and installation, generator maintenance, bilge and pollution control equipment, foam and fire suppression systems, coatings and nonskid application. Adherence to the references will be required as part of the contract award and performance for repair and maintenance of the cutter.

View the file

Other files

Show all 11

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

CONSOLIDATED LIST OF REFERENCES

The below-listed documents form a part of this specification to the extent specified herein.

Approval/publication dates or revision dates/numbers are also identified, to ensure that same document versions are used at the time of specification writing and during contract execution.

All Coast guard drawings, technical publications, and standard specifications will be provided to contractors by the Coast Guard at an appropriate time, or upon request, free of charge. Other Government documents may be accessed – free of charge – from links located on the SFLC website. Commercial sites provide access to their respective documents.

COAST GUARD DRAWINGS

Coast Guard Drawing 418A-WMSL-100-001, Rev B, General Arrangements

Coast Guard Drawing 418A-WMSL-167-001, Rev A, Fabrication & Installation Transom Doors

Coast Guard Drawing 418A-WMSL-555-001, Rev A, Foam System Diagram

Coast Guard Drawing 418A-WMSL-555-003, Rev -, AFFF Bilge Sprinkling Modifications

Coast Guard Drawing 418A-WMSL-556-001, Rev A, Stern Gate Hydraulic System Diagram

Coast Guard Drawing 418A-WMSL-593-001, Rev A, Bilge & Oil Pollution Control System

Diagram

Coast Guard Drawing 418A-WMSL-801-001, Rev A, Booklet of General Plans

Coast Guard Drawing 418A-WSML-540-001, Rev B, Fuel Oil Diagram

Coast Guard Drawing 418-WMSL-079-754, Rev -, CGC JAMES Damage Control Information

Coast Guard Drawing 750-WMSL-100-021, Rev F, Unit 2100 Structure – Inner Bottom – Fr 35 to Fr 44 (ASC100210)

Coast Guard Drawing 750-WMSL-100-022, Rev K, Unit 2110 Structure Inner Bottom to 1st Pltf

Fr 35 – 44 (ASC100210)

Coast Guard Drawing 750-WMSL-100-045, Rev K, 2nd Dk to Main Dk - FR 82 to Aft

(ASC100333)

Coast Guard Drawing 750-WMSL-167-001, Rev J, Manhole List Installation and Fabrication

Details Ship Wide (ASC167001)

Coast Guard Drawing 750-WMSL-303-002, Rev D, Coordination of Protective Devices

(ASC303004)

Coast Guard Drawing 750-WMSL-320-038, Rev B, Electrical One Line Diagram (ASC320001)

Coast Guard Drawing 750-WMSL-320-039, Rev B, Electrical One Line Diagram (NSC2 - SRD)

(ASC320001B) (UNSIGNED)

Coast Guard Drawing 750-WMSL-320-043, Rev C, Electrical One Line Diagram (NSC5-SRD)

(ASC320001E) (UNSIGNED)

Coast Guard Drawing 750-WMSL-520-025, Rev B, Saltwater Cooling System Diagram SRD

NSC 5

Coast Guard Drawing 750-WMSL-520-507, Rev G, Auxiliary Seawater Piping Mods Aft of FR

Coast Guard Drawing 750-WMSL-555-016, Rev D, Foam System Unit 2230 (ASC555223-AF)

Coast Guard Drawing 750-WMSL-555-020, Rev D, Foam System Unit 2330 (ASC555233-AF)

Coast Guard Drawing 750-WMSL-555-026, Rev C, Foam System Unit 3130 (ASC555313-AF)

Coast Guard Drawing 750-WMSL-555-030, Rev B, Foam System Unit 3230 (ASC555323-AF)

Coast Guard Drawing 750-WMSL-555-038, Rev D, Foam System Unit 4420 (ASC555442-AF)

Coast Guard Drawing 750-WMSL-555-040, Rev C, Foam System Unit 2110 (ASC555211-AF)

Coast Guard Drawing 750-WMSL-555-042, Rev B, Foam System Unit 2210 (ASC555221-AF)

Coast Guard Drawing 750-WMSL-555-044, Rev D, Foam System Unit 2310 (ASC555231-AF)

Coast Guard Drawing 750-WMSL-555-505, Rev -, AFFF Low Point Drains Installation

Coast Guard Drawing 750-WMSL-556-22, Rev H, Steering Gear and Stern Gate Hydraulic

Piping - Unit 3330 (ASC556333-HY)

Coast Guard Drawing FL-1204-3, Rev A, Fleet Welded Padeyes and Links

COAST GUARD PUBLICATIONS

Coast Guard Commandant Instruction (COMDTINST) M10360.3 (Series), Coatings and Color

Manual

Coast Guard Technical Publication (TP) 7165, 7-Feb 2019, Ship Service Switchboards 1S, 2S, 3S and 1SP Shore Power Volume 1

Coast Guard Technical Publication (TP) 7166, 7-Feb 2019, Ship Service Switchboards 1S, 2S, 3S and 1SP Shore Power Volume 2

Coast Guard Technical Publication (TP) 7167, 7-Feb 2019, Ship Service Switchboards 1S, 2S, 3S and 1SP Shore Power Volume 3

Coast Guard Technical Publication (TP) 7176, 02 Oct 2007, Panelboard Rated 600 Volts or Less

Coast Guard Technical Publication (TP) 7346A, SWBS 593, Mar 2022, Bilge Water Separator

Ultra-Sep

Coast Guard Technical Publication (TP) 7410, Feb 2022, SWBS 593, Duplex Basket Strainer –

Sizes 3/4" – 8" – Model 50

Coast Guard Memorandum, Jan 2018, Waterfront Load Limit Restrictions – Base Charleston

Pier Papa

Surface Forces Logistics Center Standard Specification 0000 (SFLC Std Spec 0000), 2022, General Requirements

Surface Forces Logistics Center Standard Specification 0450 (SFLC Std Spec 0450), 2022, Electrical Power for Contractor Tools and Equipment

Surface Forces Logistics Center Standard Specification 0740 (SFLC Std Spec 0740), 2022, Welding and Allied Processes

Surface Forces Logistics Center Standard Specification 0850 (SFLC Std Spec 0850), 2022, General Requirements for Drawing Preparation

Surface Forces Logistics Center Standard Specification 3041 (SFLC Std Spec 3041), 2022, Shipboard Electrical Cable Test

Surface Forces Logistics Center Standard Specification 3042 (SFLC Std Spec 3042), 2022, Shipboard Electrical Cable Removal, Relocation, Splice, Repair, and Installation

Surface Forces Logistics Center Standard Specification 3100 (SFLC Std Spec 3100), 2022, Inspect, Test and Recondition AC Synchronous Generator in-Place

Surface Forces Logistics Center Standard Specification 5000 (SFLC Std Spec 5000), 2022, Auxiliary Machine Systems

Surface Forces Logistics Center Standard Specification 5550 (SFLC Std Spec 5550), 2022, Fire

Prevention and Response

Surface Forces Logistics Center Standard Specification 6310 (SFLC Std Spec 6310), 2022, Requirements for Preservation of Ship Structures

Surface Forces Logistics Center Standard Specification 8635 (SFLC Std Spec 8635), 2022, Temporary Services

Coast Guard Technical Publication (TP) 7794, April 2022, Sliding Double Transom Door -

Model H-WK-868-29 (Hulls 752 & ON)

OTHER REFERENCES

ASTM International (ASTM) A53, July 2020, Standard Specification for Pipe, Steel, Black and

Hot-Dipped, Zinc-Coated Welded and Seamless

ASTM International (ASTM) D1330, 2015, Standard Specification for Rubber Sheet Gaskets

ASTM International (ASTM) F708, 2018, Standard Practice for Design and Installation of Rigid

Pipe Hangers

Code of Federal Regulations (CFR) Title 29, Part 1910, 2017, Occupational Safety and Health

Standards

Code of Federal Regulations (CFR) Title 29, Part 1915, 2013, Occupational Safety and Health

Standards for Shipyard Employment

Code of Federal Regulations (CFR) Title 29, Part 1915, Occupational Safety and Health

Standards for Shipyard Employment

Code of Federal Regulations (CFR) Title 29, Part 1915, Subpart E, Apr 2022, Scaffolds, Ladders and Other Working Surfaces

Code of Federal Regulations (CFR) Title 40, 2013, Protection of the Environment

MIL-PRF-24667C, May 2008, Coating System, Non-Skid, for Roll, Spray, or Self-Adhering

Application

MIL-STD-419E, Aug 2017, Cleaning and Protecting Piping, Tubing and Fittings for Hydraulic

Power Transmission Equipment

National Electrical Manufacturers Association (NEMA) Stds, Pub. No. AB4, 2003, Guidelines for Inspection and Preventive Maintenance of Molded Case Circuit Breakers Used in

Commercial and Industrial Applications

NAVSEA Technical Publication T9074-AD-GIB-010/1688, (TP 1688), July 2012, Requirements for Fabrication, Welding, and Inspection of Submarine Structure

NFPA 70E: 2015 Edition Standard for Electrical Safety in the Work Place

Schneider Electric Maintenance and Field Testing Guide for Masterpact NT and NW Circuit

Breaker Instruction Bulletin No.06131B1202 Aug 2015

Society of Automotive Engineers (SAE) Aerospace Material Specification (AMS) G-6032A, 2012, Grease, Plug Valve, Gasoline and Oil Resistant, NATO Code Number G-363, Metric

The Society for Protective Coatings (SSPC) Surface Preparation Specification No.11 (SSPC-SP

11), 2020, Power Tool Cleaning to Bare Metal.

Underwriters Laboratories Inc. (UL) 489, May 2002, Molded Case Circuit Breaker

US Environmental Protection Agency Method 1664, Feb 1999, N-Hexane Extractable Material and Silica Gel Treated N-Hexane Extractable Material by Extraction and Gravimetry.