Attch_2_-_TitleII_Drawings_100_Final_12April2023.pdf

PDF 10 MB Posted

Attached to
ZZYZX FIRE FLOW TANK AND WELL UPGRADE
Solicitation number
140P8123B0001
Issued by

About this file

This file is an attachment to a federal contract solicitation for upgrading a fire flow tank and well. The solicitation number is 140P8123B0001 and was issued by the Department of the Interior National Park Service Pacific West Region for the ZZYZX FIRE FLOW TANK AND WELL UPGRADE opportunity. The attachment is a set of title drawings related to the required upgrades, and includes design plans for renovating existing infrastructure to meet fire suppression needs. Responses to the solicitation are due on or before the dates specified in the solicitation document.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

100% FINAL TITLE II CONSTRUCTION DRAWINGS

APPROVED FOR CONSTRUCTION

BY

ENGINEER-OF-RECORD

STEVEN L. BOSILJEVAC, P.E.

REGIONAL CIVIL ENGINEER

12 APRIL 2023

BY

ENGINEER-OF-RECORD

STEVEN L. BOSILJEVAC, P.E.

WELL PUMPS ELECTRICAL CONTROLS LOGIC PARAMETERS

A. Electrical controls for both pump/motor assemblies (domestic & aquatic/fire tank supply) must allow both manual operation and automated operation utilizing a separate Hands-Off-Auto switch for each pump/motor assembly controls. The HOA switch for the aquatic/fire tank supply pump/motor assembly shall have two separate “Auto” settings: Auto Setting #1 - for the automated control from the tank float switches, and Auto Setting #2 - for the automated control from the time-clock functionality.

B. Both pump/motor assemblies' electrical controls shall be on separate electrical circuits to allow simultaneous pumping from both pump/motor assemblies.

D. The domestic pump/motor assembly shall have its on-call and off-call normally controlled in the automated operation setting using the float switches in the 2,500 gallons water storage tanks.

E. The fire tank supply pump/motor assembly shall be normally operated in automated functional mode of the aquatic/fire tank supply pump/motor assembly will be controlled by the float switches in the fire tanks (with only one tank's float switch being active (selected) at any given time.)

F. The automated pumping to aquatic habitat functionality of the aquatic/fire tank supply pump/motor assembly's electrical controls shall be controlled using timer functionality for a specified duration within each 24-hour period.

100% FINAL TITLE II CONSTRUCTION DRAWINGS

APPROVED FOR CONSTRUCTION

BY

ENGINEER-OF-RECORD

STEVEN L. BOSILJEVAC, P.E.

BY

ENGINEER-OF-RECORD

STEVEN L. BOSILJEVAC, P.E.

BY

ENGINEER-OF-RECORD

STEVEN L. BOSILJEVAC, P.E.

100% FINAL TITLE II CONSTRUCTION

DRAWINGS

APPROVED FOR CONSTRUCTION

BY

ENGINEER-OF-RECORD

STEVEN L. BOSILJEVAC, P.E.

BY

ENGINEER-OF-RECORD

STEVEN L. BOSILJEVAC, P.E.

2023-04-12T17:02:52-0700
STEVEN BOSILJEVAC

File details come from the government source that posted it. Updated .