This document is a technical specification sheet for the Salvajor Trough Collector Model S419, a recirculating water system for scrapping and collecting food waste in commercial kitchens. Key details include:
The Trough Collector system uses recirculated water to swiftly convey food waste down a trough and into a collector, minimizing the need for manual scrapping. It can handle high-volume dish output from large conveyor or flight dishwashers. The system is 32 7/8" to 35 7/8" adjustable height, with a 22" minimum overhead clearance. It requires 3/4" hot and cold water supply, a 2" tank drain, and 115V, 208V, or 230V 1-phase or 208V, 230V, or 460V 3-phase power. The specification sheet provides detailed dimensions, utility connection requirements, and options like remote controls and gusher heads.
This specification sheet is related to a federal contract opportunity, Solicitation Number 36C26024Q0476, for a Soiled Tray Conveyor System issued by the Department of Veterans Affairs Veterans Health Administration.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C26024Q0476 0001.docx | DOCX document | |
| 36C26024Q0476.docx | DOCX document | |
| Attachement EUCCW6 Specs.pdf | ||
| S02 52.225-2 BUY AMERICAN CERTIFICATE.docx | DOCX document | |
| NFS CONVEYOR-30X42.pdf | ||
| Attachment Spec Sheet Soiled Tray Scrapping System 11S A.pdf | ||
| P07 WD King 2015-5535 Rev 21 12.23.23.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
A Trough Conveying and Food Waste Collecting System
Widely accepted in areas that restrict the use of food waste disposers.
Job: Item No.:
Model S419
Recirculated Water used by the system for scrapping reduces water and sewer costs. The Trough Collector consumes only 2 gallons of fresh water per minute.
Trough Water Volume with the Trough Collector is 70 gallons per minute. This volume swiftly propels food waste down the trough and into the Collector with no additional hand movement, leaving both hands free for high-volume scrapping. The Trough Collector will let you keep up with large conveyor or flight dishmachines.
Design Flexibility is offered by the Collector as troughs can turn corners. The Collector’s high water volume allows the design of wider, longer troughs allowing you to soak problem dishes or add gusher heads to pre-rinse compartmental trays.
HydroLogic Water Saving Control has an adjustable timer with user friendly LCD readout.
Typical trough layout
Typical trough layout is 12" wide and 10' in length with up to 2 optional gusherheads spaced 3' - 4' apart to accommodate 2 operators.
Trough CollectorTM
14 7/8" (37.78)
4 3/16" (10.60)
4 9/16" (11.62)
4 9/16" (11.62)
LEFT SIDE VIEW
32 7/8" (83.50) adjustable to 35 7/8" (91.12)
18 1/8" (46.10)
11 5/8" (29.45)
FRONT VIEW
22" (55.88) miniumum clearance overhead for basket removal
Air Gap
One basket provided with unit Additional basket recommended at additional cost Scrap Basket dimensions 18 9/16" dia. x 131/4" high (47.2) dia. x (33.7) high
We suggest the use of rubber Gusher Heads along the trough for scrapping and pre-flushing. One per operator, two max.
(Optional at additional cost) 1 5/16" diameter hole required in trough.
Fabricated trough (not furnished), must have matching flange to attach to trough connection.
(See detail "C")
11/2" plumbing fittings and valve (See detail "B")
3/4" pipe and valve (See detail "B")Removable Trough Collector top can be rotated in 15˚ increments.
Hot and cold shutoff valves
1/2” NPT
Control Panel can be mounted on left or right.
1/2” conduit knockout electrical connection
Water Diffuser furnished. 2" diameter hole required in back of trough. (See detail "A")
7 7/16" (18.82) to
10 7/16" (26.44)
1 7/16" (3.65)
UTILITY
CONNECTION
UTILITY
CONNECTION
UTILITY
CONNECTION
Tank drain
2” NPT
NOTE: Dimensions in parenthesis are in centimeters
TOP VIEW
22 1/2" (57.15)
12 1/4" (31.11)
11 1/4" (28.58) ø19 1/4" (ø48.84)
TABLE CUTOUT DETAIL
12 1/4" (31.12)
6 1/2" (16.51) ø20" (ø50.75)
TOP VIEW
22 1/2" (57.15)
12 1/4" (31.11)
11 1/4" (28.58) ø19 1/4" (ø48.84)
TABLE CUTOUT DETAIL
12 1/4" (31.12)
6 1/2" (16.51) ø20" (ø50.75)
Recirculation Plumbing (Not Furnished)
Plumb per diagram for correct operation
11/2"
3/4"
1 5/16" dia.
hole
5 1/2" (14.0)
R 1/4" (R.63)
4 " (10.2)
8 3/4"(22.2) 5 3/4"(14.6)
Trough Section
2" dia.
hole
3" min.
depth Diffuser
Locknut Gasket
DETAIL "A" _ WATER DIFFUSER
• Trough must have a minimum 3" depth with a fall of at least 3/32" per running foot towards the collector.
• Minimum 6" clearance is required from the trough to the wall to allow room for recirculation piping.
• 22" minimum clearance overhead for basket removal.
An additional basket is recom-mended at additional cost.
Detail "A" - Water Diffuser Detail "C" - Trough Connection Flange
Detail "B" - Recirculation
Trough Collector™ Model S419
90°
15°
The control can be mounted on either side of the Collector using existing mounting bracket, mounting holes, fasteners and wiring for dish flow to the left or dish flow to the right.
The Trough Collector top can be rotated in 15 degree increments to ease common installations as well as improve design flexibility without the need of costly tank modifications.
Upon request, the Trough Collector top may be shipped separately to an alternate location for fabrication.
2" Tank Drain (Piping not furnished)
All connections are to be made by qualified personnel who will observe all local and national codes.
Slots 3/8" x 1"
(.95 x 2.54) 9 7/8" (25.08)
2 3/4" (6.99)
11" (27.94)
4" (10.16)
8" (20.32)
5" (12.70)
5/8" (1.59)
5" (12.70)
# 980104 Optional Remote Control Mounting Bracket
UTILITY
CONNECTIONS
The control can be mounted remotely using optional remote mounting bracket. Note: Additional field wiring is necessary.
• Incoming electrical connection ➔ factory wired control panel
• Incoming hot/cold water connection ➔ factory plumbed water harness
• Drain connection ➔ 2” NPT
Trough Collector™ Model S419
CONSTRUCTION
n Tank - 2 Piece Stainless Steel n Adjustable Legs - Stainless Steel n Control Panel - Stainless Steel n Salvage Basin - High Impact Polymer n Scrap Basket - High Impact Polymer
ELECTRICAL
n Pre-wired NEMA 4 Control Panel n Watertight Conduit /Fittings n Separate Component Grounding n Thermally Protected Motor n Safety Line Disconnect n 24 Volt Safety Circuitry
PLUMBING
n Corrosion Resistant Components n Automatic Water Blender n Unions n Check Valves n Incoming Water Valves n Non-clogging Pump Design n Pump Intake Screen
ACCESSORIES
Remote Start-Stop Remote Mounting Bracket Correctional Package Control Mounting Bracket Additional Scrap Basket Rack Guide Full Stainless Cover Gusher Heads
UTILITIES REQUIRED
1. Electric service
2. 3/4" hot and cold water supply and reduce to 1/2" at connection.
3. 2" tank drain.
(Specifications subject to change without notice.)
SAMPLE SPECIFICATIONS
Unit shall be a Salvajor Trough Collector, a complete scrapping, pre-flushing and food waste collecting system with recirculating water as manufactured by Salvajor.
Model S419,____Volts, 60Hz, ___Phase.
Furnished with a pre-wired control panel and stainless steel NEMA 4 watertight enclosure.
115V 208V 230V, 60 Cycle, 1 Phase 208V 230V 460V, 60 Cycle, 3 Phase
Pump Motor ¾ HP
VOLTAGES AVAILABLE
(SPECIFY EXACT OPERATING VOLTAGE)
FULL LOAD AMPS
(SPECIFY EXACT OPERATING VOLTAGE)
1 PHASE 3 PHASE
115V 208V 230V 208V 230V 460V 11 5.5 5.5 3.2 3 1.5
Trough CollectorTM
Model S419 Specifications
4530 East 75th Terrace Kansas City, MO 64132-2081, USA
816.363.1030 I Toll Free: 1.800.725.8256 I Service: 1.888.725.8256 I Fax: 1.800.832.9373 sales@salvajor.com I service@salvajor.com I www.salvajor.com
Printed in USA Form No. S419 (05-18)
Manufacturers of Commercial Food Waste Solutions - Since 1944
File details come from the government source that posted it. Updated .