Attachment D-LBJ 7th Floor.pdf
PDF 3 MB Posted
- Attached to
- Commercial Cable Television Services Federal contract opportunity
- Solicitation number
- 91991521R0007
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| VendorQuestionsCableTV-91991521R0007.xlsx | XLSX spreadsheet | |
| Evaluation Criteria - Cable Services.docx | DOCX document | |
| Attachment F-PCP Cable TV Locations.pdf | ||
| Attachment B Required Channels.docx | DOCX document | |
| Attachment G- UCP Cable Television Locations.pdf | ||
| Attachment A Television List.xlsx | XLSX spreadsheet | |
| Attachment C- LBJ 4th Floor.pdf | ||
| Attachment E- LBJ Cable TV Locations.pdf | ||
| Attachment H- Coax-Cable Count.xlsx | XLSX spreadsheet | |
| SOW_CableTV_v.2.docx | DOCX document |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Job No.
Drawn Check Owner Approval
Delta Issue Date
Title
Sheet
Description
Scale
SENSITIVE BUT UNCLASSIFIED (SBU)
PROPERTY OF THE UNITED STATES GOVERNMENT
FOR OFFICIAL USE ONLY
Do not remove this notice
Properly destroy or return documents when no longer needed
/1
/2
:1 :1
P
M
DEPARTMENT OF
EDUCATION - 7TH
FLOOR
PM, PA/JC, AND TDCC, EN, AND HP
03JLLX.0292.000
POTOMAC CENTER
SOUTH
550 12TH STREET SW
WASHINGTON, DC
20024
SCHEDULES
EQUIPMENT SCHEDULE
LIGHT FIXTURE SCHEDULE
F15 LINEAR BULB SUSPENDED NA MENU 1495639-UL
3500K 24 W MATTE OPAL / BLACK
TO BE INSTALLED OVER ISLAND; PROVIDE 3500K
LED BULBS.
F14 ROUND SURFACE MOUNT NA HALO PR6M12MD9FSMW 3500K 20.4 W MATTE WHITE
F13 CUBE LED FLUSH MOUNT NA BLACKJACK LIGHTING CUB-15F-PC-12T-30K 3000K 23.2 W POLISHED CHROME / MATTE WHITE
F12 LARGE OVAL SUSPENDED 6'-10" LIGHTNET 1ZP3OWD-835H-L3000-K 3500K 345 W SNOW WHITE TO BE INSTALLED CONCENTRICALLY
F11 MEDIUM OVAL SUSPENDED 6'-10" LIGHTNET 1ZP3OWD-835H-L2000-K 3500K 228 W SNOW WHITE TO BE INSTALLED CONCENTRICALLY
F10 SMALL OVAL SUSPENDED 6'-10" LIGHTNET 1ZP3OWD-835H-L1500-K 3500K 163 W SNOW WHITE TO BE INSTALLED CONCENTRICALLY
F8 SUSPENDED PENDANT - CHAIN MOUNT 8'-0" (COORD. W/ RACKS/EQUIP) METALUX 4SNLED-LD5-47SL-LW-UNV-L835-CD-1-U-AYC-Chain/Set 3500K 41 W WHITE LAN ROOM FIXTURE; COORD HEIGHT AFF W/ EQUIP
F7 EXIT SIGN PER ELECTRICAL PER ELECTRICAL PER ELECTRICAL NA NA MATCH BUILDING STANDARD
F5 SUSPENDED LINEART DIRECT/INDIRECT - 4" W X 4' L 8'-0" FOCAL POINT Seem4: FSM4BS-FLFL-375DN-1000UP-35K-1C-UNV-L11-C48-WH-4' 3500 K 32 W WHITE
F3 RECESSED DOWNLIGHT - 4" DIA. NA FOCAL POINT FLC3D-RO-1500L-UNV-LD1-T-LC3-RO-1500L-35K-DNS-WFL-CD 3500 K 17 W CLEAR DIFFUSE REFLECTOR AND TRIM FLANGE
F2 2X4 RECESSED LED NA FOCAL POINT Equation: FEQ2-24-AC-6000LH-35K-1C-UNV-LD1-[GRID]-WH 3500 K 51 W WHITE
F1 2X2 RECESSED LED NA FOCAL POINT Equation: FEQ2-22-AC-5000LH-35K-UNV-LD1-[GRID]-WH 3500 K 36 W WHITE
MARK DESCRIPTION MOUNTING HEIGHT A.F.F. MANUFACTURER MODEL COLOR TEMP INPUT WATTAGE FINISH NOTES
WASHINGTON D.C.
600 NEW HAMPSHIRE AVE. NW STE 200
WASHINGTON, D.C. 20037
TEL 202-945-6500 FAX 202-945-6501
© INTERIOR ARCHITECTS, P.C., A NEW YORK PROFESSIONAL SERVICES
CORPORATION. ALL DRAWINGS AND WRITTEN MATERIAL HEREIN CONSTITUTE
THE ORIGINAL AND UNPUBLISHED WORK OF THE ARCHITECT, AND THE SAME
MAY NOT BE DUPLICATED, USED, OR DISCLOSED WITHOUT THE WRITTEN
CONSENT OF THE ARCHITECT.
1 ISSUE FOR PERMIT/PRICING 8/12/21
52 LOCKERS AS NOTED ON PLANS STEELCASE UNIVERSAL RDD242445LDP ■ ■
51 FREE STANDING SMALL TRASH BIN AS NOTED ON PLANS BY OWNER BY OWNER ■ ■
50 WATERBOTTLE FILLER AS NOTED ON PLANS ELKAY EZH2O MODEL LZWSSM ■ ■ PROVIDE POWER AS REQ'D
48 MOBILE MAGNETIC GLASS MARKERBOARD AS NOTED ON PLANS CLARUS GO! MOBILE
■ ■ MAGNETIC, ON CASTERS, BLACK FRAME, WHITE BACKPAINTED GLASS, WHITE
CASTERS
46 WALL-MOUNTED MONITOR (42") AS NOTED ON PLANS BY OWNER BY OWNER ■ ■
45 MOBILE AV CART AS NOTED ON PLANS BY OWNER BY OWNER ■ ■
44 GLASS MAGNETIC MARKERBOARD, 4X4 AS NOTED ON PLANS CLARUS FLOAT (OR EQUAL) WHITE BACKPAINTED GLASS MAGNETIC BOARD
WITH BOX TRAY ■ ■ PROVIDE BLOCKING AS REQ'D; SEE A700 SHEET SERIES FOR ADDITIONAL INFO;
MARKERBOARD TRAY INCLUDED
42 WALL-MOUNTED PHONE AS NOTED ON PLANS BY OWNER BY OWNER
COORDINATE POWER/DATA AND MOUNTING REQUIREMENTS W/OWNER PRIOR TO
ROUGH-IN
40 WALL-MOUNTED MONITOR (75") MEDIUM CONFERENCE ROOMS BY OWNER BY OWNER ■ ■ WITH CAMERA, SPEAKERS AND MICROPHONES
37 GLASS MAGNETIC MARKERBOARD, 4X6 AS NOTED ON PLANS CLARUS FLOAT (OR EQUAL) WHITE BACKPAINTED GLASS MAGNETIC BOARD
WITH BOX TRAY ■ ■ PROVIDE BLOCKING AS REQ'D; SEE A700 SHEET SERIES FOR ADDITIONAL INFO;
MARKERBOARD TRAY INCLUDED
32 RECYCLE CONTAINER AS NOTED ON PLANS ALLE 23 GL BLUE BIN 22" W X 11" D X 30" H ■ ■ COORDINATE SIZE WITH CLEAR FLOOR SPACE
31 COPIER/PRINTER AS NOTED ON PLANS BY OWNER BY OWNER ■ ■
30 FULL-SIZE COPIER/PRINTER NOT USED BY OWNER BY OWNER ■ ■ REQUIRES DEDICATED OUTLET
29 SHREDDER AS NOTED ON PLANS BY OWNER BY OWNER ■ ■ need sizing for clear floor space
27 MICROWAVE AS NOTED ON PLANS SAMSUNG MS19M8000A ■ ■
25 UNDER COUNTER TRASH BIN AS NOTED ON PLANS ALLE 8128 WASTEBASKET/14.38"W x 15"D x 10.25"H
COORD SIZE WITH MILLWORK CUTOUT IN COUNTER; INCLUDE GROMMET
20 TOWEL DISPENSER STAFF LOUNGE, PANTRY ULINE H-5995 ■ ■
19 MIRROR MOTHERS ROOM BOBRICK B-165 SPECIAL ORDER SIZE ■ ■ CUSTOM SIZE TO ALIGN WITH MILLWORK; SIZE 24" x 36" MIN TO BE ACCESSIBLE
14 UNDER COUNTER REFRIGERATOR MOTHERS ROOM SUMMIT FF1843BADA ■ ■
13 WALL-MOUNTED TOWEL DISPENSER MOTHERS ROOM BOBRICK B-35903 ■ ■
12 FULL-LENGTH MIRROR MOTHERS ROOM BOBRICK B-165 2460 ■ ■
11 SOAP DISPENSER W/ MOTION SENSOR MOTHERS ROOM BOBRICK B-8263 ■ ■
10 ADA UNDERMOUNT SINK MOTHERS ROOM KOHLER CAXTON K-20000 ■ ■
9 FAUCET W/ MOTION SENSOR MOTHERS ROOM AMERICAN STANDARD PARADIGM SELECTRONIC ■ ■ INTEGRATED PROXIMITY LAVATORY FAUCET, POLISHED CHROME
8 VENDING MACHINE STAFF LOUNGE, PANTRY BY OWNER BY OWNER ■ ■
7 FULL-SIZE REFRIGERATOR AS NOTED ON PLANS WHIRLPOOL WRS315SNHM ■ ■
6 FREE STANDING LARGE TRASH BIN AS NOTED ON PLANS ALLE RCR42313SS 3 STREAM TAPERED RECYCLE
CENTER ■ ■
5 4X6 MAGNETIC GLASS MARKERBOARD AS NOTED ON PLANS CLARUS FLOAT (OR EQUAL) WHITE BACKPAINTED GLASS MAGNETIC BOARD
WITH BOX TRAY ■ ■
PROVIDE BLOCKING AS REQ'D; SEE A700 SHEET SERIES FOR ADDITIONAL INFO;
MARKERBOARD TRAY INCLUDED
4 GARBAGE DISPOSAL STAFF LOUNGE, PANTRY INSINKERATOR LIGHT DUTY MODEL LC-50 ■ ■
2 DOUBLE BOWL UNDERMOUNT SINK AS NOTED ON PLANS EKLAY ELUHAD311850
■ ■ EKLAY LUSTERTONE CLASSIC EQUAL DOUBLE BOWL UNDERMOUNT ADA SINK
1 FAUCET WITH SIDE SPRAYER STAFF LOUNGE, PANTRY KOHLER PURIST k-7508 ■ ■
MARK ITEM LOCATION MANUFACTURER STYLE, MODEL NUMBER
FURNISHED BY
GC
FURNISHED
BY AGENCY
INSTALLED
BY GC
INSTALLED BY
AGENCY
REMARKS Notes for Agency
Priscilla.Whyte Highlight
P 2 2
WALL
DPY
CR
TSAT
P 2 2
FLR
GB
EL
EDR
DR
ML
OS
REX
PB
ADA
PH
CH
M
GFI
#4
D P
Y
DPY
DPY
PWALL PWALL
P W
A L L
D P
Y
DPY
D P
Y
DPY
P W
A L L
P W
A L L
48" +48"
48" +48"
+48" 48"
P WALL
PWALL
+48" 48"
CR
CRCR
C R
C R
P W
A L L
P W
A L L
P W
A L L
P W
A L L
P WALL
P WALL
P WALL
P WALLP WALL
P WALL
PWALLP WALLP WALL
P WALLP WALLP WALL
P W
A L L
P W
A L L
P W
A L L
PWALL
P W
A L L
CR
PWALL
PWALL PWALL
PWALL
P W
A L L
P W
A L L
C R
A D
A
P H
C R
A D
A
P H
D P
Y
P W
A L L
P H
P H
C R
P H
PH
PH
P WALL
P FLR
P W
A L L
P W
A L L
D P
Y
PWALLPWALL
PWALLPWALL
P W
A L L
A D
A
ADA
DPY
D P
Y
D P
Y
DPY
D P
Y
DPY
C R
P W
A L L
C R
DPY
DPY
D P
Y
DPY
C R
A D
A
A D
A
G F
I
GFI
+42"
WALL MOUNTED DUPLEX OUTLET
WALL MOUNTED DEDICATED OUTLET
WALL MOUNTED QUAD OUTLET DUPLEX OUTLET WITHIN POKE-THRU DEVICE
GARBAGE DISPOSAL - SWITCH IN BASE CAB UNDER
SINK
DATA OUTLET WITHIN POKE-THRU DEVICE
TELEPHONE/DATA OUTLET
WALL MOUNTED CARD READER
WALL MOUNTED PUSH BUTTON
WALL MOUNTED THERMOSTAT
FLOOR WHIP - DATA/POWER
WALL WHIP - DATA/POWER
JUNCTION BOX WITHIN POKE-THRU DEVICE
DISPLAY LOCATION CENTERLINE - PROVIDE DUPLEX
RECEPTACLE, DATA DROP AND COAX CABLE BEHIND
DISPLAY IN CHIEF BACKBOX (OR APPROVED EQ.)
DISPLAYS TO BE MOUNTED AT 66" AFF
AREA NOT IN CONTRACT
AV
EQUIPMENT DESIGNATIONX
FURNITURE MOUNTED DUPLEX OUTLET
FURNITURE MOUNTED TELEPHONE/DATA OUTLET
ANNOTATIONS AND DEFINITIONS
KEY NOTESSHEET NOTESPOWER & SIGNAL LEGEND
FURNISH: SUPPLY AND DELIVER TO PROJECT SITE READY FOR UNLOADING, UNPACKING & INSTALLATION.
INSTALL: OPERATIONS ON PROJECT SITE INCL. UNLOADING, TEMP. STORING, UNPACKING, INSTALLING, ASSEMBLING, PLACING, ANCHORING, APPLYING, FINISHING, PROTECTING, CLEANING ETC.
PROVIDE: FURNISH AND INSTALL, COMPLETE READY FOR THE INTENDED USE.
D - DENOTES DEMOLITION
E - DENOTES EXISTING TO REMAIN
R - DENOTES RELOCATED
+42" - INDICATES MOUNTING HEIGHT A.F.F.
1. SEE 000-SHEET SERIES FOR ADDITIONAL NOTES AND ABBREVIATIONS.
2. SEE ENGINEERING AND A/V DRAWINGS FOR ADDITIONAL INFORMATION. ANY DISCREPANCIES TO BE ISSUED TO ARCHITECT IN RFI PRIOR TO COMMENCEMENT OF
WORK.
3. G.C. TO COORDINATE ALL FINAL FLOOR CORE LOCATIONS WITH FURNITURE VENDOR, OWNER AND ARCHITECT PRIOR TO START OF WORK. ALL FLOOR AND WALL
CORING SHALL BE SCHEDULED DURING OFF HOURS UNLESS OTHERWISE ALLOWED BY OWNER.
4. G.C. TO MAINTAIN EXISTING UL FIRE RATED ASSEMBLY FOR ALL PENETRATIONS.
5. ALL NEW DEVICES AND COVER PLATES, STROBES, SWITCHES, AND PLUGS, ETC. TO BE WHITE AT PAINTED WHITE/OFF-WHITE WALLS AND FABRIC WALL AREAS
U.O.N. ALL DEVICES AND COVER PLATE COLORS AT ACCENT WALLS TO BE VERIFIED WITH ARCHITECT. REPLACE EXISTING COVER PLATES, PLUGS, SWITCHES, ETC.
WITH NEW. SUBMIT COLOR SELECTION TO ARCHITECT PRIOR TO START OF WORK.
6. WHERE DEVICES ARE SHOWN BACK TO BACK, OFFSET AS REQUIRED TO COMPENSATE FOR BOX AND STUD DIMENSIONS. USE CENTER POINT BETWEEN DEVICE
LOCATIONS AS REFERENCE POINT FOR LOCATION DIMENSION U.O.N.
7. COORDINATE DEVICE LOCATIONS PRIOR TO START OF WORK INCLUDING, BUT NOT LIMITED TO, THE FOLLOWING CONDITIONS SYSTEM FURNITURE LAYOUT, FREE STANDING AND BUILT-IN FURNITURE, MILLWORK , STRUCTURAL COLUMN LINES AT 'POKE-THROUGH' LOCATIONS & FACE OF FINISH AT PARTITIONS AND FLOOR.
WHERE APPLICABLE CONDUCT PRE-INSTALLATION CONFERENCE.
8. WHERE 'WHIPS' ARE SCHEDULED FOR SYSTEM FURNITURE, PROVIDE COMPLETE CODE COMPLIANT INSTALLATION INCLUDING, BUT NOT LIMITED TO 'WHIP' MUST BE VISIBLE AND READILY ACCESSIBLE, SYSTEM FURNITURE 'WHIP' INSTALLATION, HOOK UP AND ACTIVATION SHALL COMPLY WITH LOCAL LABOR LAWS AND JURISDICTION REQUIREMENTS INCLUDING UL., LOCATE 'WHIP' OUTSIDE CLEAR ZONES REQUIRED FOR CIRCULATION, ADA ACCESSIBLE ROUTES AND EXIT PATH.
9. FUTURE VENDOR SHALL COORDINATE FURNITURE INSTALLATION WITH POWER/SIGNAL DEVICE LOCATIONS.
10. PROVIDE 3” MINIMUM CLEAR BETWEEN FLOOR MONUMENTS AND PARTITION.
11. PROVIDE NEMA RECEPTACLE TYPES BASED ON ELECTRICAL AND COMMUNICATION EQUIPMENT SPECIFICATIONS AS COORDINATED PRIOR TO START OF WORK
12. FOR DEDICATED OUTLETS AND RECEPTACLE MOUNTING HEIGHTS DESIGNED FOR SPECIAL EQUIPMENT, HEIGHT SHALL BE MEASURED FORM THE FINISHED FLOOR TO THE CENTERLINE OF THE OUTLET MOUNTED VERTICALLY, UNLESS NOTED OTHERWISE. RECEPTACLE, SWITCH AND OUTLET MOUNTING HEIGHT DIMENSIONS ARE MEASURED FROM FINISHED FLOOR TO OUTLET CENTERLINE MOUNTED VERTICALLY, UNLESS NOTED OTHERWISE.
13. PRIOR TO START OF WORK VERIFY AND COORDINATE ELECTRICAL BUS DUCT AND CONDUIT, RISER AND HORIZONTAL ROUTING, RUN LOCATIONS, CIRCUITING AND WIRING FOR NEW WORK TO VALIDATE REQUIRED CLEARANCES BASED ON AS-BUILT FIELD CONDITIONS. BRING CONFLICTS WHERE OCCUR TO ARCHITECT’S
ATTENTION.
14. ALL ELECTRICAL WORK AND MATERIALS SHALL BE IN COMPLIANCE WITH THE CURRENT RULES AND REGULATIONS OF THE NATIONAL BOARD OF FIRE UNDERWRITERS, THE STATE FIRE MARSHALL, THE SAFETY ORDERS OF THE DIVISION OF INDUSTRIAL SAFETY, DEPARTMENT OF INDUSTRIAL RELATIONS AND
APPLICABLE CODES. ALL EQUIPMENT SHALL BE UL LABELED.
15. BUILDING SERVICES AND UTILITY DISRUPTIONS TO THE BUILDING, INCLUDING ADJACENT TENANTS IN MULTI-TENANT BUILDINGS ARE NOT PERMITTED DURING NORMAL BUSINESS HOURS. ALL FIRE / LIFE SAFETY SYSTEMS SHALL REMAIN OPERATIONAL DURING DEMOLITION AND CONSTRUCTION ACTIVITIES DURING NORMAL BUSINESS HOURS. FOR TEMPORARY DISRUPTIONS LIMITED TO THE AREA OR WORK, AFTER HOURS AS NEEDED TO COMPLETE THE WORK, SCHEDULE DAY AND TIME WITH OWNER IN ADVANCE, IN WRITING ON AN OVERTIME BASIS. REESTABLISH ALL BUILDING SERVICES AND UTILITIES AT CONCLUSION OF TEMPORARY SHUT OFF, AS SOON AS PRACTICAL.
16. REFERENCE A702 FOR MOUNTING HEIGHTS DIAGRAMS.
17. REFER TO 007-SHEET FOR EQUIPMENT SCHEDULE.
18. ALL TEL/DATA SCOPE, INLCUDING # OF DROPS, SHOWN ON THE IT DRAWINGS.
19. REVIEW OUTLET LOCATIONS (DIMENSIONS) WITH FURNITURE/EQUIPMENT SIZES AND PLACEMENT IN FIELD
20. SEE E-SHEETS FOR GFI OUTLETS
ELECTRIFIED LOCKSET & ELECTRIFIED HINGE
EMERGENCY DOOR RELEASE PULL
DOOR RELEASE PULL
ELECTROMAGNETIC LOCK
OCCUPANCY SENSOR RELEASE
PUSH TO EXIT RELEASE BUTTON
PANIC BUTTON
PHONE; PROVIDE DATA DROP
LIGHT CONTROL
INDICATES DEVICES CENTERED VERTICALLY
QUAD OUTLET WITHIN POKE-THRU DEVICE
MONITORS IN CORRIDORS AND CONFERENCE ROOMS TO BE
RECESSED AS REQUIRED TO NOT PROJECT MORE THAN 4".
DIMENSION NOTES
1. CENTER DEVICES ON COLUMN, U.O.N.
2. REQUIRED OFFSET FOR BACK TO BACK DEVICES OVERRULE DIMENSIONS.
3. REVIEW OUTLET LOCATIONS (DIMENSIONS) WITH FURNITURE/EQUIPMENT SIZES AND PLACEMENT IN FIELD
DOOR CHIME
DUPLEX OUTLET WITHIN MILLWORK
DATA
TEL/DATA
GFCI DUPLEX OUTLET
2 3 4 5 6 7 8 9 10 11 12 13 14 15
H
K
L
M
N
P
Q
R
S
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
TEAM
ROOM
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
TEAM
ROOM
TEAM
ROOM
PANTRY
TEAM
ROOM
STORAGE
NETWORK
ENGINEER
LAB
WORKBENCH
DESKTOP
ENGINEER
LAB
LAN
ROOM
LARGE
CONFERENCE
ROOM
LARGE
CONFERENCE
ROOM
LARGE
CONFERENCE
ROOM
SES
OFFICE
SES
OFFICE
SES
OFFICE
SES
OFFICE
COPY/PRINT
7101-1
COPY/PRINT
7111-19
ASSIST
TECH
LAB
SES
OFFICE
GENERAL
STORAGE
FORENSICS
ANALYSIS
STORAGE
ROOM
7105-1
STAFF
LOUNGE
MOTHER'S
ROOM
MEETING
BOOTHS
COPY/PRINT
7405-1
COPY/PRINT
7412-1
COPY/PRINT
7300-15
COPY/PRINT
7200-5
OFFICE
SECURE
STORAGE
COPY/PRINT
7101-14
COPY/PRINT
7208-16
INFORMAL
MEETING
7101-28
INFORMAL
MEETING
7101-3
INFORMAL
MEETING
7315-04
INFORMAL
MEETING
7401-9
INFORMAL
MEETING
7209-6
INFORMAL
MEETING
7208-13
INFORMAL
MEETING
7412-4
COPY/PRINT
7401-1
COPY/PRINT
7315-1
SR001
OPEN
AREA
INFORMAL
MEETING
7111-18
LOCKERS
INFORMAL
MEETING
7101-10
OPEN
AREA
LOCKERS
7101-2
OPEN
AREA
LOCKERS
7315-03
OPEN
AREA
INFORMAL
MEETING
7315-09
OPEN
AREA
INFORMAL
MEETING
7411-26
LOCKERS
LOCKERS
STORAGE
MEETING
BOOTHS
MEETING
BOOTHS
INFORMAL
MEETING
7401-2
ELEV
LOBBY
A700
A701
3' -0
3' -0
3' -0
3' -8
" 3' -8
3' -0
3' -0
3' -0
3' -0
3' -0
3' -0
3'-0"
3' -0
3' -8
3' -0
3' -8
3' -0
3' -0
2' -2
3' -0
3'-0"
3' -0
3'-0"
3'-8"
3'-0"
3' -0
1' -4
6' -0
6' -8
6' -0
6' -0
6' -0
6' -0
6' -0
6' -0
6' -0
6'-0"
1' -4
1' -4
1' -8
1' -4
1' -8
4'-0"
31 51
3'-8"
4' -0
4' -0
MEETING
BOOTHS
52 52
52 52 52
52 52
52 52 52 52 52
52 52 52 52
52 52 52 52 52 52
52 52 52 52 52
52 52
52 52
52 52
52 52
52 52
52 52
52 52
52 52
52 52
52 52
52 52
52 52 52
52 52 52
Job No.
Drawn Check Owner Approval
Delta Issue Date
Title
Sheet
Description
Scale
SENSITIVE BUT UNCLASSIFIED (SBU)
PROPERTY OF THE UNITED STATES GOVERNMENT
FOR OFFICIAL USE ONLY
Do not remove this notice
Properly destroy or return documents when no longer needed
1/8" = 1'-0"
/1
/2
:1 :4
P
M
DEPARTMENT OF
EDUCATION - 7TH
FLOOR
KS, CC, AND MDCC, EN, AND HP
03JLLX.0292.000
POTOMAC CENTER
SOUTH
550 12TH STREET SW
WASHINGTON, DC
20024
A201
7TH FLOOR POWER
AND SIGNAL PLAN
NO. DESCRIPTION
221 POWER FROM LADDER TRAY ABOVE. SEE E-SHEETS
228 PROVIDE (2) 1 1/4" CONDUIT FROM BACKBOX (BEHIND MONITOR) TO POKE THRU DEVICE BELOW TABLE. PROVIDE PULL BOXES
AS REQUIRED. EXTEND CONDUIT FROM BACKBOX TO ABOVE ACCESSIBLE CEILING.
WASHINGTON D.C.
600 NEW HAMPSHIRE AVE. NW STE 200
WASHINGTON, D.C. 20037
TEL 202-945-6500 FAX 202-945-6501
© INTERIOR ARCHITECTS, P.C., A NEW YORK PROFESSIONAL SERVICES
CORPORATION. ALL DRAWINGS AND WRITTEN MATERIAL HEREIN CONSTITUTE
THE ORIGINAL AND UNPUBLISHED WORK OF THE ARCHITECT, AND THE SAME
MAY NOT BE DUPLICATED, USED, OR DISCLOSED WITHOUT THE WRITTEN
CONSENT OF THE ARCHITECT.
1 ISSUE FOR PERMIT/PRICING 8/12/21
1/8" = 1'-0"
7TH FLOOR POWER SIGNAL PLAN
Priscilla.Whyte Rectangle
Priscilla.Whyte Rectangle
Priscilla.Whyte Rectangle
Priscilla.Whyte Rectangle
Priscilla.Whyte Rectangle
Priscilla.Whyte Rectangle
Priscilla.Whyte Rectangle
Priscilla.Whyte Rectangle
Priscilla.Whyte Rectangle
Priscilla.Whyte Rectangle
Priscilla.Whyte Rectangle
Priscilla.Whyte Rectangle
Priscilla.Whyte Rectangle
Priscilla.Whyte Rectangle
Priscilla.Whyte Rectangle
Priscilla.Whyte Rectangle
Priscilla.Whyte Rectangle
Priscilla.Whyte Rectangle
Priscilla.Whyte Rectangle
Priscilla.Whyte Rectangle
Priscilla.Whyte Rectangle
P W
A L L
PH
D P
Y
+48"
CR/PP
P WALL
D P
Y
C R
/P
PP
H C H
P
P FLR P FLR
D P
Y
D P
Y
D P
Y
D P
Y
D P
Y
D P
Y
D P
Y
D P
Y
D P
Y
P 2 2
WALL
DPY
CR
TSAT
P 2 2
FLR
GB
EL
EDR
DR
ML
OS
REX
PB
ADA
PH
CH
M
2 3 4
N
P
Q
SA2
SA3 SA2
SA2
B03
B03
B03
SECURE
ROOM
SR7213
SECURE
ROOM
SECURE
MEETING
ROOM
B03
F03
B04
B04
B04MECH
SR7212
MECH
SR7213A
B03
SR7210SR7211
SR7213
SR7212
F08
F08
SR00310 SR003
SR003 10SR003
SR00312
B04
B04
SR003
SR003
SR003
SR003
SR7213A
F06
4'-6"
5' -8
7'
-0
2"
35'-7"
9'-1"
36'-2"
2"
12'-7"
7' -4
3'-10"
F03
3' -1
0"
135°
5' -2
L
M
N
2 3 4
N
P
SECURE
ROOM
SR7213
SECURE
ROOM
SECURE
MEETING
ROOM
MECH
SR7212
MECH
SR7213A
31 30
31 29
2' -1
53 53
54 54
FLOOR TO CEILING WINDOW
PARTIAL HEIGHT WINDOW (WITH SILL)
DOOR TAG (DOOR NUMBER BASED ON ROOM NUMBER
WITH ALPHA SUFFIX IF MULTIPLE)
EXISTING CONSTRUCTION TO REMAIN
NEW 2HR FIRE RESISTANT RATED PARTITION
NEW CONSTRUCTION
AREA N.I.C.
NEW MILLWORK WITH OVERHEAD CABINETS
FIRE EXTINGUISHER FIRE EXTINGUISHER CABINETFE FEC
+42" - INDICATES MOUNTING HEIGHT A.F.F.
A
B03
1. SEE 000-SHEET SERIES FOR ADDITIONAL NOTES AND ABBREVIATIONS.
2. PROVIDE IN-WALL BLOCKING AT ALL WALL-MOUNTED FLAT SCREENS; LOCATION AND EXTENT OF BLOCKING TO BE COORDINATED WITH OWNER'S AV VENDOR.
3. USE TYPE "X" GWB ON FIRE RATED PARTITIONS.
4. PROVIDE INSULATION FULL DEPTH OF STUD OF ALL PARTITIONS. INSULATION AT RATED PARTITIONS TO BE NON-COMBUSTIBLE, MINERAL WOOL OR EQUIVALENT APPROVED IN THE PROJECT
JURISDICTION.
5. USE CEMENTITIOUS BACKER BOARD ('DUROCK') OR EQUAL AT PARTITIONS SCHEDULED TO RECEIVE CERAMIC TILE (U.O.N.). SEE FINISH PLAN FOR LOCATION OF TILE.
6. WHERE FURRED PARTITIONS EXCEED MAXIMUM HEIGHT, BRACE TO ADJACENT STRUCTURE. SEE A-8 DETAIL SHEET SERIES.
7. FIRE SAFE PENETRATIONS AT FIRE RESISTANT RATED PARTITIONS PER APPLICABLE UL ASSEMBLY. SEE A8 SHEET SERIES FOR DETAILS.
8. MAINTAIN INTEGRITY OF EXISTING FIRE RESISTANT RATED ASSEMBLIES FOR ALL PENETRATIONS.
9. PROVIDE BLOCKING AS REQUIRED AT LOCATIONS INCLUDING, BUT NOT LIMITED TO: GRAB BARS, SHELVING, OVERHEAD CABINETS, SIGNAGE, TOILET ROOM ACCESSORIES, WALL MOUNT. EQUIPMENT, ETC.
10. PROVIDE LEVEL 4 FINISH U.O.N. PROVIDE LEVEL 5 FINISH AT ALL PARTITIONS TO RECEIVE SPECIALTY WALL FINISH INCLUDING BUT NOT LIMITED TO WALLCOVERING, ACOUSTIC WALL TREATMENTS, GRAPHICS, ETC. REFER TO FINISH PLANS FOR LOCATIONS AND ADDITIONAL INFORMATION.
11. LARGE SCALE DRAWINGS TAKE PRECEDENCE OVER SMALL SCALE DRAWINGS. DETAILS TAKE PRECEDENCE OVERALL, NOTIFY ARCHITECT IN WRITING WHERE DISCREPANCIES OCCUR.
12. ALL EXPOSED OUTSIDE GYPSUM BOARD CORNERS SHALL HAVE A CONTINUOUS METAL CORNER BEAD.
13. DIMENSIONS TAKEN FROM PERIMETER EXTERIOR WINDOW WALL ARE TAKEN FROM THE INSIDE FACE OF THE VERTICAL MULLION. DIMENSIONS MARKED VERIFY IN FIELD, SHALL BE VERIFIED PRIOR TO
START OF WORK UNLESS OTHERWISE NOTED.
14. CONTRACTOR SHALL COORDINATE WORK WITH HVAC, MECHANICAL, ELECTRICAL, PLUMBING, DESIGN BUILD FIRE PROTECTION AND STRUCTURAL DRAWINGS AND REPORT TO THE ARCHITECT
DISCREPANCIES FOR CORRECTION AND ADJUSTMENT PRIOR TO START OF WORK. NO ALLOWANCE WILL BE MADE FOR INCREASED COST DUE TO THE CONTRACTOR’S LACK OF COORDINATION.
15. PATCH FLOOR AND WALL AREAS DAMAGED DUE TO NEW CONSTRUCTION OR WHERE PENETRATIONS HAVE BEEN MADE FOR MECHANICAL, ELECTRICAL AND PLUMBING WORK. FIRESAFE AT UL RATED
ASSEMBLIES CONSISTENT WITH EXISTING UL RATING.
16. WHERE EXISTING RATED ASSEMBLIES ARE SHOWN, CONTRACTOR IS REQUESTED TO FIELD VERIFY AS BUILT FIELD CONDITIONS TO CONFIRM RATINGS SHOWN. IF NON-COMPLIANT CONDITIONS ARE
FOUND, DEMO AND REPLACE WITH NEW EQUIVALENT UL ASSEMBLY, OR REPORT FINDINGS TO OWNER/ARCHITECT IN WRITING WHO WILL PROVIDE WRITTEN DIRECTION.
17. PATCH AND REPAIR ALL EXISTING PARTITIONS AFTER DEMOLITION WHERE DAMAGE HAS OCCURRED AT UNPROTECTED LOCATIONS. PLEASE NOTE THAT DEMOLITION ACTIVITY MAY OCCUR BEYOND WORK
LIMITS SHOWN ON DEMOLITION PLAN DUE TO CONCEALED CONDITIONS.
18. ADD NEW FURRING PARTITIONS AROUND ALL INTERIOR COLUMNS. SEE TYPICAL DETAIL.
19. AT ALL EXTERIOR PARTITIONS/PILASTERS TO RECEIVE POWER/DATA DEVICES OR FURNITURE WHIPS - GC TO NOTIFY ARCHITECT IF EXISTING WALL DEPTH CANNOT ACCOMMODATE SCHEDULED DEVICES
20. PATCH FIREPROOFING.
21. GC TO CONFIRM WITH TENANT ON WHERE IN-WALL BLOCKING IS REQUIRED FOR OFFICE FURNITURE ITEMS.
22. SEE SR005 FOR PARTITION SCHEDULE.
KEY NOTESPARTITION PLAN LEGEND
EXISTING 2HR FIRE RESISTANT RATED PARTITION
PARTITION TYPE (SEE PARTITION SCHEDULE)
KEYNOTE
202.
NEW 1HR FIRE RESISTANT RATED PARTITION
PARTITION PLAN NOTES
POWER SIGNAL PLAN LEGEND
POWER SIGNAL PLAN NOTES
DEMOLITION PLAN LEGEND
DEMOLITION PLAN NOTES
EXISTING CONSTRUCTION TO BE DEMOLISHED
AREA N.I.C.
EXISTING MILLWORK TO BE DEMOLISHED
EXISTING CONSTRUCTION TO REMAIN
EXISTING 2HR FIRE RESISTANT RATED PARTITION TO REMAIN
1. SEE 000 SERIES FOR ADDITIONAL NOTES AND ABBREVIATIONS.
2. ALL EXISTING WORK TO REMAIN UNLESS OTHERWISE NOTED.
3. PROTECT AND MAINTAIN EXISTING FIRE RATED CONSTRUCTION. REPLACE AND REPAIR DAMAGED FIRE RATED CONSTRUCTION WITH NEW, MATCHING EXISTING AND UL ASSEMBLY.
4. PROTECT WORK AREA INCLUDING NEW AND EXISTING MATERIALS AND FINISHES FROM DAMAGE WHICH MAY OCCUR FROM CONSTRUCTION, DEMOLITION, DUST, WATER, ETC. PROVIDE AND MAINTAIN
TEMPORARY BARRICADES, CLOSURE WALLS, AS REQUIRED TO PROTECT THE PUBLIC AND BUILDING OCCUPANTS DURING CONSTRUCTION. DAMAGE TO NEW AND EXISTING STRUCTURES, EQUIPMENT, MATERIALS AND FINISHES SHALL BE REPAIRED OR REPLACED TO THE SATISFACTION OF THE OWNER AT THE SOLE EXPENSE OF THE CONTRACTOR.
5. EXISTING WINDOW SHADES TO BE PROTECTED IN PLACE DURING CONSTRUCTION. ANY SHADES THAT ARE BROKEN DURING CONSTRUCTION ARE TO BE REPLACED BY GC.
6. REMOVE EXISTING FINISH MATERIALS (INCLUDING WALLCOVERING) THROUGHOUT, U.O.N. PREPARE SURFACES FOR NEW FINISHES.
7. ALL EXISTING CEILINGS AND LIGHT FIXTURES TO BE REMOVED, TYP. U.O.N. REMOVE ALL WIRING AND SUPPORTS, CLEAN AND PREPARE FOR NEW WORK.
8. REMOVE DOORS, FRAMES, AND HARDWARE AS NOTED, U.O.N.
9. REMOVE DEMOUNTABLE PARTITIONS AS NOTED, U.O.N.
10. REMOVE AND DISCARD ALL FLOOR FINISHES AND WALL BASE AS WELL AS FLASH PATCH, MASTIC AND ADHESIVES DOWN TO THE STRUCTURAL CONCRETE FLOOR SLAB AND PREPARE FOR NEW
FINISHES.
11. REMOVE ALL EXISTING MATERIALS CREATING UNEVEN, OUT OF TOLERANCE SUBSTRATE INCLUDING BUT NOT LIMITED TO FASTENERS, COVER PLATES, RESILIENT FLOORING, CARPET PAD, ETC.
12. REMOVE ALL CABINETRY, SIGNAGE, CORNER GUARDS, SHELVING, EQUIPMENT, EXPOSED BLOCKING, WALL MOUNTED ACCESSORIES.
13. ALL LIFE SAFETY DEVICES SHALL REMAIN ACTIVE DURING DEMOLITION AND CONSTRUCTION.
14. REMOVE ANY EXISTING OUTLETS AT EXTERIOR AND CORE WALLS, AS WELL AS COLUMNS AND CORE POKE THRU DEVICES.
15. AT RATED ASSEMBLIES, PROTECTS AND MAINTAIN EXISTING UL COMPONENTS AS REQUIRED TO RETAIN UL RATING.
16. REMOVE AND SALVAGE ALL FEC DEVICES AND RETURN TO OWNER.
17. REMOVE EXISTING FURRING AT ALL INTERIOR COLUMNS.
18. REMOVE EXISTING LOW VOLTAGE CABLING, CABLING SWITCHES, TEL/DATA/AV WIRING AND ASSOCIATED CONDUIT. WHERE SOURCE, FUNCTION OR TERMINATION IS UNKNOWN - SCOPE IS TO BE
REVIEWED IN FIELD WITH BUILDING MANAGEMENT AND TENANT.
EXISTING 2HR FIRE RESISTANT RATED PARTITION TO DEMOLISHED
WALL MOUNTED DUPLEX OUTLET
WALL MOUNTED DEDICATED OUTLET
WALL MOUNTED QUAD OUTLET DUPLEX OUTLET WITHIN POKE-THRU DEVICE
GARBAGE DISPOSAL - SWITCH IN BASE CAB UNDER
SINK
DATA OUTLET WITHIN POKE-THRU DEVICE
TELEPHONE/DATA OUTLET
WALL MOUNTED CARD READER
WALL MOUNTED PUSH BUTTON
WALL MOUNTED THERMOSTAT
FLOOR WHIP - DATA/POWER
WALL WHIP - DATA/POWER
JUNCTION BOX WITHIN POKE-THRU DEVICE
DISPLAY LOCATION CENTERLINE - SEE E-SHEETS FOR
POWER REQS. SEE IT SHEETS FOR DATA.
(COORDINATE WITH AV DRAWINGS FOR HT. AND
AV CONNECTIONS)
AREA NOT IN CONTRACT
AV
EQUIPMENT DESIGNATIONX
FURNITURE MOUNTED DUPLEX OUTLET
FURNITURE MOUNTED TELEPHONE/DATA OUTLET
ANNOTATIONS AND DEFINITIONS
FURNISH: SUPPLY AND DELIVER TO PROJECT SITE READY FOR UNLOADING, UNPACKING & INSTALLATION.
INSTALL: OPERATIONS ON PROJECT SITE INCL. UNLOADING, TEMP. STORING, UNPACKING, INSTALLING, ASSEMBLING, PLACING, ANCHORING, APPLYING, FINISHING, PROTECTING, CLEANING ETC.
PROVIDE: FURNISH AND INSTALL, COMPLETE READY FOR THE INTENDED USE.
D - DENOTES DEMOLITION
E - DENOTES EXISTING TO REMAIN
R - DENOTES RELOCATED
+42" - INDICATES MOUNTING HEIGHT A.F.F.
1. SEE 000-SHEET SERIES FOR ADDITIONAL NOTES AND ABBREVIATIONS.
2. SEE ENGINEERING AND A/V DRAWINGS FOR ADDITIONAL INFORMATION. ANY DISCREPANCIES TO BE ISSUED TO ARCHITECT IN RFI PRIOR TO COMMENCEMENT OF WORK.
3. G.C. TO COORDINATE ALL FINAL FLOOR CORE LOCATIONS WITH FURNITURE VENDOR, OWNER AND ARCHITECT PRIOR TO START OF WORK. ALL FLOOR AND WALL CORING SHALL BE SCHEDULED DURING
OFF HOURS UNLESS OTHERWISE ALLOWED BY OWNER.
4. G.C. TO MAINTAIN EXISTING UL FIRE RATED ASSEMBLY FOR ALL PENETRATIONS.
5. ALL NEW DEVICES AND COVER PLATES, STROBES, SWITCHES, AND PLUGS, ETC. TO BE WHITE AT PAINTED WHITE/OFF-WHITE AND FABRIC WALL AREAS U.O.N. ALL DEVICES AND COVER PLATES AT
WOOD VENEER WALLS TO BE STAINLESS STEEL U.O.N. ALL DEVICES AND COVER PLATE COLORS AT ACCENT WALLS TO BE VERIFIED WITH ARCHITECT. REPLACE EXISTING COVER PLATES, PLUGS, SWITCHES, ETC. WITH NEW. SUBMIT COLOR SELECTION TO ARCHITECT PRIOR TO START OF WORK.
6. WHERE DEVICES ARE SHOWN BACK TO BACK, OFFSET AS REQUIRED TO COMPENSATE FOR BOX AND STUD DIMENSIONS. USE CENTER POINT BETWEEN DEVICE LOCATIONS AS REFERENCE POINT FOR
LOCATION DIMENSION U.O.N.
7. COORDINATE DEVICE LOCATIONS PRIOR TO START OF WORK INCLUDING, BUT NOT LIMITED TO, THE FOLLOWING CONDITIONS SYSTEM FURNITURE LAYOUT, FREE STANDING AND BUILT-IN FURNITURE, MILLWORK , STRUCTURAL COLUMN LINES AT 'POKE-THROUGH' LOCATIONS & FACE OF FINISH AT PARTITIONS AND FLOOR. WHERE APPLICABLE CONDUCT PRE-INSTALLATION CONFERENCE.
8. WHERE 'WHIPS' ARE SCHEDULED FOR SYSTEM FURNITURE, PROVIDE COMPLETE CODE COMPLIANT INSTALLATION INCLUDING, BUT NOT LIMITED TO 'WHIP' MUST BE VISIBLE AND READILY ACCESSIBLE, SYSTEM FURNITURE 'WHIP' INSTALLATION, HOOK UP AND ACTIVATION SHALL COMPLY WITH LOCAL LABOR LAWS AND JURISDICTION REQUIREMENTS INCLUDING UL., LOCATE 'WHIP' OUTSIDE CLEAR
ZONES REQUIRED FOR CIRCULATION, ADA ACCESSIBLE ROUTES AND EXIT PATH.
9. FUTURE VENDOR SHALL COORDINATE FURNITURE INSTALLATION WITH POWER/SIGNAL DEVICE LOCATIONS.
10. PROVIDE 3” MINIMUM CLEAR BETWEEN FLOOR MONUMENTS AND PARTITION.
11. PROVIDE NEMA RECEPTACLE TYPES BASED ON ELECTRICAL AND COMMUNICATION EQUIPMENT SPECIFICATIONS AS COORDINATED PRIOR TO START OF WORK
12. FOR DEDICATED OUTLETS AND RECEPTACLE MOUNTING HEIGHTS DESIGNED FOR SPECIAL EQUIPMENT, HEIGHT SHALL BE MEASURED FORM THE FINISHED FLOOR TO THE CENTERLINE OF THE OUTLET
MOUNTED VERTICALLY, UNLESS NOTED OTHERWISE. RECEPTACLE, SWITCH AND OUTLET MOUNTING HEIGHT DIMENSIONS ARE MEASURED FROM FINISHED FLOOR TO OUTLET CENTERLINE MOUNTED
VERTICALLY, UNLESS NOTED OTHERWISE.
13. PRIOR TO START OF WORK VERIFY AND COORDINATE ELECTRICAL BUS DUCT AND CONDUIT, RISER AND HORIZONTAL ROUTING, RUN LOCATIONS, CIRCUITING AND WIRING FOR NEW WORK TO VALIDATE REQUIRED CLEARANCES BASED ON AS-BUILT FIELD CONDITIONS. BRING CONFLICTS WHERE OCCUR TO ARCHITECT’S ATTENTION.
14. ALL ELECTRICAL WORK AND MATERIALS SHALL BE IN COMPLIANCE WITH THE CURRENT RULES AND REGULATIONS OF THE NATIONAL BOARD OF FIRE UNDERWRITERS, THE STATE FIRE MARSHALL, THE SAFETY ORDERS OF THE DIVISION OF INDUSTRIAL SAFETY, DEPARTMENT OF INDUSTRIAL RELATIONS AND APPLICABLE CODES. ALL EQUIPMENT SHALL BE UL LABELED.
15. BUILDING SERVICES AND UTILITY DISRUPTIONS TO THE BUILDING, INCLUDING ADJACENT TENANTS IN MULTI-TENANT BUILDINGS ARE NOT PERMITTED DURING NORMAL BUSINESS HOURS. ALL FIRE /
LIFE SAFETY SYSTEMS SHALL REMAIN OPERATIONAL DURING DEMOLITION AND CONSTRUCTION ACTIVITIES DURING NORMAL BUSINESS HOURS. FOR TEMPORARY DISRUPTIONS LIMITED TO THE AREA OR WORK, AFTER HOURS AS NEEDED TO COMPLETE THE WORK, SCHEDULE DAY AND TIME WITH OWNER IN ADVANCE, IN WRITING ON AN OVERTIME BASIS. REESTABLISH ALL BUILDING SERVICES AND
UTILITIES AT CONCLUSION OF TEMPORARY SHUT OFF, AS SOON AS PRACTICAL.
16. REFERENCE A702 FOR MOUNTING HEIGHTS DIAGRAMS.
17. REFER TO 007-SHEET FOR EQUIPMENT SCHEDULE.
18. ALL TEL/DATA SCOPE, INLCUDING # OF DROPS, SHOWN ON THE IT DRAWINGS.
19. REVIEW OUTLET LOCATIONS (DIMENSIONS) WITH FURNITURE/EQUIPMENT SIZES AND PLACEMENT IN FIELD
20. SEE E-SHEETS FOR GFI OUTLETS
ELECTRIFIED LOCKSET & ELECTRIFIED HINGE
EMERGENCY DOOR RELEASE PULL
DOOR RELEASE PULL
ELECTROMAGNETIC LOCK
OCCUPANCY SENSOR RELEASE
PUSH TO EXIT RELEASE BUTTON
PANIC BUTTON
PHONE; PROVIDE DATA DROP
LIGHT CONTROL
INDICATES DEVICES CENTERED VERTICALLY
QUAD OUTLET WITHIN POKE-THRU DEVICE
DOOR CHIME
DUPLEX OUTLET WITHIN MILLWORK
POWER POLE
PP
A SR7213
H2 7211
A 7210
P
P
Job No.
Drawn Check Owner Approval
Delta Issue Date
Title
Sheet
Description
Scale
SENSITIVE BUT UNCLASSIFIED (SBU)
PROPERTY OF THE UNITED STATES GOVERNMENT
FOR OFFICIAL USE ONLY
Do not remove this notice
Properly destroy or return documents when no longer needed
1/8" = 1'-0"
/1
/2
:1 :2
P
M
DEPARTMENT OF
EDUCATION - 7TH
FLOOR
CheckerAuthor
03JLLX.0292.000
POTOMAC CENTER
SOUTH
550 12TH STREET SW
WASHINGTON, DC
20024
SR001
7TH FLOOR SECURE
ROOM PLANS
1/8" = 1'-0"
7TH FLOOR SECURE ROOMS PARTITION PLAN
1/8" = 1'-0"
7TH FLOOR SECURE ROOMS DEMOLITION PLAN
1/8" = 1'-0"
7TH FLOOR SECURE ROOMS POWER SIGNAL PLAN
WASHINGTON D.C.
600 NEW HAMPSHIRE AVE. NW STE 200
WASHINGTON, D.C. 20037
TEL 202-945-6500 FAX 202-945-6501
© INTERIOR ARCHITECTS, P.C., A NEW YORK PROFESSIONAL SERVICES
CORPORATION. ALL DRAWINGS AND WRITTEN MATERIAL HEREIN CONSTITUTE
THE ORIGINAL AND UNPUBLISHED WORK OF THE ARCHITECT, AND THE SAME
MAY NOT BE DUPLICATED, USED, OR DISCLOSED WITHOUT THE WRITTEN
CONSENT OF THE ARCHITECT.
1 ISSUE FOR PERMIT/PRICING 8/12/21
NO. DESCRIPTION
021 ROOMS NOT TO BE DEMOLISHED UNTIL NEW ROOMS ARE BUILT.
154 REINFORCE PARTITION AS REQUIRED FOR MULTIPLE LOADS.
225 REFER TO MEP DRAWINGS FOR POWER INFRASTRUCTURE.
226 SEE AV DRAWINGS FOR PATHWAY FROM MONITORS TO DESK.
227 SEE ELEVATION FOR POWER DEVICE QUANTITIES, LOCATIONS AND MOUNTING HEIGHTS
228 PROVIDE (2) 1 1/4" CONDUIT FROM BACKBOX (BEHIND MONITOR) TO POKE THRU DEVICE
BELOW TABLE. PROVIDE PULL BOXES AS REQUIRED. EXTEND CONDUIT FROM BACKBOX TO
ABOVE ACCESSIBLE CEILING.
SECURE ROOM SR7213 - SHALL COMPLY WITH:
TECHNICAL SPECIFICATIONS FOR CONSTRUCTION AND
MANAGEMENT OF SENSITIVE COMPARTMENTED INFORMATION
FACILITIES VERSION 1.1
IC TECH SPEC-FOR ICD/ICS 705
REQUIREMENTS FOR AN OPEN STORAGE FACILITY WITH SID
1/8" = 1'-0"
7TH FLOOR SECURE ROOMS SIGNAGE PLAN
Priscilla.Whyte Rectangle
Priscilla.Whyte Rectangle
Priscilla.Whyte Rectangle
Priscilla.Whyte Typewritten Text 9 TVs
| PCP 7th Floor Cable TV Locations_21.08.30.pdf |
| Pages from 21_0813_DoED 7th Floor Pricing Set_Full.pdf |
File details come from the government source that posted it. Updated .