Attachment_B_-_Specifications_3510-CS-0189764.pdf
PDF 128 KB Posted
- Attached to
- Statewide Contract CA|1-25-35-10A|0000222094
- Contract number
- 1-25-35-10A
- Issued by
- California
About this file
This document is a contract specification for extractors and dryers issued by the California Department of General Services (DGS) for the California Department of Forestry and Fire Protection (CAL FIRE). The contract specification is identified by the number 3510-CS-0189764 and was released on December 31, 2024, with Attachment B detailing the technical requirements for personal protective equipment (PPE) cleaning and drying equipment.
The specification outlines comprehensive technical requirements for front-loading extractors and tumble/portable dryers designed specifically for wildland and structural firefighting PPE ensemble elements. The equipment must comply with current National Fire Protection Association (NFPA) 1851 standards, with specific requirements including programmable wash and dry cycles, chemical dosing capabilities, maximum cylinder speeds of 100G, and maximum drying temperatures of 105°F. The extractors and dryers are intended to clean and maintain protective gear for firefighting personnel, with precise specifications for electric and gas configurations, detergent application, water temperature control, and cycle programming to ensure proper maintenance of protective ensembles.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Attachment_A_-_Contract_Pricing_FDES.xlsx | XLSX spreadsheet | |
| Attachment_6-Technical_Questionnaire_.xlsx | XLSX spreadsheet |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
State of California Extractors and Dryers
California Department of Forestry and Fire Protection
Contract Specification
3510-CS-0189764
Contract 1-25-35-10 Attachment B
Velazquez, I. Page 1 of 3 Dec 31, 2024
Document Summary Detail Type Detail Contract Number 1-25-35-10 Contract Description Extractors and Dryers Attachment B Group-Class 3510 Contract Specification 3510-CS-0189764 Release Date December 31, 2024 Agency Name California Department of Forestry and Fire Protection
Revision History Specification Rev Rev Date Author Summary of Changes 3510-BS-0189764 N/A N/A Velazquez, I Initial release of bid spec
3510-CS-0189764 N/A N/A Velazquez, I Initial release of contract spec
DGS PD Extractors and Dryers 3510-CS-0189764
Velazquez, I. Page 2 of 3 Dec 31, 2024
1. SCOPE
This specification defines the technical requirements for personal protective equipment (PPE) extractors and dryers to be used by California Department of Forestry and Fire Protection (CAL FIRE) personnel. The extractors and dryers shall be suitable for use with wildland and structural firefighting PPE ensemble elements including but not limited to structural turnout coats & pants, particulate blocking hoods, wildland jackets, dual compliant single layer pants, and wildland shrouds.
2. APPLICABLE LAWS and INDUSTRY STANDARDS The following standards, laws, regulations, and codes of the issue in effect on the date of the Invitation for Bid form (IFB) are part of this specification to the extent specified herein. Any applicable laws, regulations, codes, industry standards, or manufacturing standards, though not specifically cited, shall apply.
2.1 Laws, Regulations, and Codes
2.1.1 California Code of Regulations (CCR), Title 8, Article 10.1, Section
3402.3, Selection, Inspection, and Maintenance of Protective Ensembles for Structural Fire Fighting and Proximity Fire Fighting
2.1.2 CCR, Title 8, Article 10.1, Section 3410, Selection, Inspection, and Maintenance of Protective Ensembles for Wildland Fire Fighting
2.2 Industry Standards
2.2.1 National Fire Protection Association (NFPA) 1851, Standard on
Selection, Care, and Maintenance of Protective Ensembles for Structural Fire Fighting and Proximity Fire Fighting, current edition
2.2.2 NFPA 1877, Standard on Selection, Care, and Maintenance of Wildland Firefighting Protective Clothing and Equipment, current edition
3. TECHNICAL REQUIREMENTS
3.1 Extractors
3.1.1 Extractors must meet the requirements of the current edition of NFPA 1851, Standard on Selection, Care, and Maintenance of Protective Ensembles for Structural Fire Fighting and Proximity Fire Fighting.
3.1.2 Extractors must be front loading.
3.1.3 Extractors must meet the requirements of the NFPA 1851 wash cycles, including the following programmable features, at time of delivery:
a. Detergent application
b. Water temperature
c. Water level
d. Cycle type
e. Cycle function
f. Cycle time
3.1.4 Extractors must be equipped with a chemical dosing, two solution pump, that is pre-configured to the extractor and detergent.
3.1.5 The maximum cylinder speed must be 100G.
DGS PD Extractors and Dryers 3510-CS-0189764
Velazquez, I. Page 3 of 3 Dec 31, 2024
3.2 Tumble Dryers
3.2.1 Tumble dryers must meet the requirements of the current edition of the
NFPA 1851, Standard on Selection, Care, and Maintenance of Protective Ensembles for Structural Fire Fighting and Proximity Fire Fighting.
3.2.2 Tumble dryers must have a maximum drying temperature of 105 °F.
3.2.3 Tumble dryers must be of electric or gas configuration.
3.2.4 Tumble dryers must be programmed to meet NFPA 1851 drying cycles at the time of delivery.
3.3 Portable Dryers
3.3.1 Portable dryers must meet the requirements of the current edition of the NFPA 1851, Standard on Selection, Care, and Maintenance of Protective Ensembles for Structural Fire Fighting and Proximity Fire Fighting.
3.3.2 Portable dryers must have a maximum drying temperature of 105 °F.
3.3.3 Portable dryers must be of electric configuration.
3.3.4 Portable dryers must be programmed to meet NFPA 1851 drying cycles at the time of delivery.
End of document
| Document Summary |
| Revision History |
| 1. SCOPE |
| 2. APPLICABLE LAWS and INDUSTRY STANDARDS |
| 2.1 Laws, Regulations, and Codes |
| 2.2 Industry Standards |
| 3. TECHNICAL REQUIREMENTS |
| 3.1 Extractors |
| 3.2 Tumble Dryers |
| 3.3 Portable Dryers |
File details come from the government source that posted it. Updated .