About this file

This is a Qualified Product Policy document issued by the South Carolina Department of Transportation (SCDOT) establishing procedures and requirements for precast concrete drainage structure manufacturers to be listed on Qualified Product List 14. The policy outlines comprehensive qualification processes for multiple product categories, including precast reinforced concrete floorless culverts, rectangular drainage boxes, risers, circular drainage structures, headwalls, and various drainage accessories. Manufacturers seeking qualification must submit third-party certification from either the American Concrete Pipe Association (ACPA) or National Precast Concrete Association (NPCA), completed qualification forms, and product documentation. For floorless culverts specifically, manufacturers must submit design methodology, project histories with GPS coordinates, and two representative as-built project designs or full-scale structural load test data at least 45 business days in advance of listing. SCDOT requires manufacturers to notify the Concrete Materials Supervisor a minimum of 14 business days prior to fabricating any floorless culvert sections for use within SCDOT rights-of-way to allow for inspection coordination. All products must be marked with the date of manufacture, product description, AASHTO/ASTM designation, facility identifier, and third-party certification indicator.

The policy mandates that manufacturers must be listed on Qualified Product List 14 on the project let date to provide bids for SCDOT projects. SCDOT reserves the right to conduct random unannounced spot inspections and may remove suppliers from the qualified product list or require additional inspections and documentation at any time if product conformance or suitability is compromised. Manufacturers are responsible for providing annual third-party certification documentation and notifying SCDOT in writing of any changes in contact information or facility ownership, with ownership changes potentially triggering additional plant inspections. The policy emphasizes that manufacturers must comply with all SCDOT Standard Specifications and Drawings current at the time of fabrication and must adhere to South Carolina state shipping permit requirements for manufactured products.

View the file

Other files for this state and local contract opportunity

Other files attached to CASTING GRATES, newest first.
File Type Posted
Attachment A.pdf PDF
Solicitation.pdf PDF
Amendment #1.pdf PDF
Attachment D.pdf PDF
Attachment C.pdf PDF
Attachment E.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Qualified Product Policy 14 February 22, 2019

South Carolina Department of Transportation Qualified Product Policy 14 for Manufacturers to Supply Precast Drainage Structures

1.0 General:

This policy contains the procedures required for Precast Manufacturers to have their drainage structures listed on Qualified Product List 14:

www.scdot.org/doing/rm_lab.asp

NOTICE: Effective Immediately, SCDOT requires third party certification from either ACPA or NCPA. Each Manufacturer’s facility is required to have third party certification in order to provide products for use within SCDOT rights-of-way. See ACPA at www.concrete.pipe.org or NCPA at www.precast.org for details of inspection programs.

2.0 Inspection of New Supplier Plants:

New Manufacturing Facilities:

Provide a copy of the plant’s ACPA or NPCA certificate Completed form QPL14DS (below).

Written request for initial plant inspection (email, fax, or letter) Contact: Design Standards Office Preconstruction Support 955 Park Street, Room 409 Columbia, SC 29201 Telephone: (803) 737-1377 Fax: (803) 737-0608 Email: d8designstandards@scdot.org

Random spot inspections will be performed as deemed necessary to assure compliance with this policy and product specifications.

Mark all products produced for use within SCDOT rights-of-way with the following:

a. All marks required by the plans, standard drawings, or specifications

b. Date of manufacture

c. Description of Item (consistent with QPL 14 terminology, in italics below)

d. AASHTO/ASTM designation where applicable

e. Manufacturer’s unique stamp/location identifier for the facility

f. Third party certification identifier (either “NPCA” or ACPA “Qcast”) appropriate for the facility/product being produced Where possible, mark both inside and outside of item. For outside mark, place as close to the top of the item as practical.

http://www.scdot.org/doing/rm_lab.asp http://www.concrete.pipe.org/ http://www.precast.org/ mailto:d8designstandards@scdot.org

4.0 Requests to produce precast reinforced concrete floorless culverts:

Manufacturers shall submit:

1. Completed Request form QPL14FC located at the end of this policy.

2. Design methodology or design manual

3. List of completed and ongoing floorless culvert installations with the following information for each project:

- Project Name

- Installation Date

- Location (GPS Coordinates if available)

- Floorless Culvert type, span, rise, and length

- Maximum Design Dead & Live loads

- Owner contact information

4. Copies of two (2) as built project designs and plans* preferably within the state of South Carolina (including construction revisions) and representative of the sizes and type (submit 2 projects for each type desired, flat slab, arch box, or arch) requested to be listed on QPL14.

a. Design Calculations (including foundation, structure, geotechnical report)

b. Design Drawings (location, plan, elevations, and section views)

c. Foundation Drawings

d. Shop Drawings

e. As built changes shall be noted on drawings or summarized

*Results of full scale structural loading testing may be submitted in lieu of as built plans. Load test data must verify the validity of the structural design methodology including all maximum design, fabrication, and handling stresses.. Manufacturers will only be listed up to sizes within 20% of submitted as built or tested sizes (up to 48’ span) and will only be listed up to the maximum span of the submitted design example/load test data for any size larger than 48’ span.

Submit all required information at least 45 business days in advance of being listed on QPL14 for floorless culverts.

Produce Floorless Culverts in a facility listed on QPL 14 or in a facility qualified by the SCDOT Office of Materials and Research. Notify SCDOT a minimum of 15 business days prior to fabricating sections to allow coordination with SCDOT inspectors. SCDOT will inspect all precast floorless culvert sections produced for use within SCDOT rights-of-way.

Precast manufacturer must contact the Concrete Materials Supervisor (803) 737 - 6689 at the SCDOT Office of Materials & Research at least 14 business days prior to casting any parts of a floorless culvert to be installed within SCDOT ROW.

5.0 Request to produce precast rectangular drainage boxes and risers (719-305-00, 719-310-00, & 719- 315-00):

Manufacturer shall submit

1. Structural design calculations in accordance with requirements of Standard Drawing

2. Shop drawings

Submit all required information at least 45 business days in advance of being listed on QPL14 for precast rectangular boxes and risers.

6.0 Requests to produce other listed drainage structures:

Manufacturer shall submit a certification of compliance with the SCDOT Standard Drawing. For convenience, a blank certification form (QPL14DS) is attached to this policy, by signing and submitting the certification form QPL14DS, Manufacturer agrees to fabricate all drainage structures in conformance with SCDOT Standard Specifications and Drawings.

7.0 Review Process

The SCDOT reserves the right to require additional documentation and perform random spot inspections at each facility as needed to determine the suitability of a supplier for inclusion. When random spot inspection are desired, SCDOT will arrive on-site without any prior notice. The SCDOT may, at any time, remove a supplier from the qualified product list or require additional inspections, testing, or documentation if confidence in the conformance or suitability of the supplied product is lost. Review time listed above will be extended if submittal is incomplete or additional information is required.

8.0 Updating Contact Information and Annual 3rd Party Certification Status It is the manufacturer’s responsibility to provide annual certification documentation and to notify SCDOT in writing if there are changes in contact information or ownership of any listed facility. Changes in ownership of plant may require an additional plant inspection.

Manufacturers must be listed on Qualified Product List 14 on the project let date in order to provide bids for a SCDOT project.

Manufacturers/Contractors must comply with shipping permits as required by South Carolina state law:

http://www.scdot.org/doing/OSOW.asp

SCDOT Standard Drawings are available on our website at:

www.scdot.org/doing/sd_book.shtml http://www.scdot.org/doing/OSOW.asp http://www.scdot.org/doing/sd_book.shtml

Form: QPL14DS Precast Concrete Drainage Items – Qualified Product List 14 Certification Letter (1/5)

Company Mailing Address: Plant Physical Address:

Company: _____________________ _____________________ Contact Name: _____________________ _____________________ Address: _____________________ _____________________ City: _____________________ _____________________ State: _____________________ _____________________ Postal Code: _____________________ _____________________ Phone #: _____________________ _____________________ Fax #: _____________________ _____________________ Email Address: _____________________ _____________________ Web Page: _____________________ _____________________

The company above wishes to be included on Qualified Product List 14 for the items checked below. We understand that by requesting to be placed on QPL 14, we are agreeing to comply with all of the details noted on the corresponding SCDOT Standard Specifications and Drawings.

719-001-XX CB1 Bottom Slab [46”x52”x6”] 719-001-XX Type 1 Inlet Adaptor for 4’x4’ Box [64”x64”x8”] 719-001-XX Type 1 Inlet Adaptor for 5’x5’ Box [76”x76”x8”] 719-001-XX Type 1 Inlet Adaptor for 6’x6’ Box [88”x88”x8”] 719-009-XX CB9 Bottom Slab [52”x52”x6”] 719-009-XX CB9 Top Slab [52”x52”x10”] W/ Throat Legs 719-009-XX CB9 Top Slab Manhole Type [52”x52”x10”] With Throat Legs 719-009-XX Alt CB9 Top Slab WO Throat Legs [52”x52”x5”] for brick box 719-009-XX Alt CB9 Top Slab (MH) WO Throat Legs [52”x52”x5”] for brick box 719-009-XX CB9 Inlet Adaptor for 3’x4’ box [52”x64”x8”] 719-009-XX CB9 Inlet Adaptor for 3’x5’ box [52”x76”x8”] 719-009-XX CB9 Inlet Adaptor for 3’x6’ box [52”x88”x8”] 719-015-XX CB15 Double Bottom Slab [110”x60”x6”] 719-015-XX CB15 Single Bottom Slab [70”x60”x6”] 719-015-XX CB15 Collar [60”x40”x15.5”] 719-016-XX CB16 Bottom Slab [64”x64”x6”] 719-016-XX CB16 Top Slab [66”x64”x8”] 719-016-XX CB16 Top Slab with Throat Walls [66”x64”x14”] 719-017-XX CB17 Bottom Slab [64”x64”x6”] 719-017-XX CB17 Top Slab [66”x112”x8”] 719-017-XX CB17 Throat [66”x112”x12”] 719-017-R6 CB17R5 Retrofit Top Slab [66”x112”x8”] 719-018-XX CB18 Bottom Slab [64”x64”x6”] 719-018-XX CB18 Top Slab [66”x160”x8”] 719-018-XX CB18 Throat [66”x160”x12”] 719-018-R8 CB18R7 Retrofit Top Slab [66”x160”x8”] 719-025-XX CB25 Bottom Slab for 4’x7’ Box 719-025-XX CB25 Inlet Adaptor for 4’x7’ Box (Double) 719-025-XX CB25 Inlet Adaptor for 4’x7’ Box (Single)

Form: QPL14DS Precast Concrete Drainage Items – Qualified Product List 14 Certification Letter (2/5)

Company: ____________________________

719-025-XX CB25 Bottom Slab 4’x5’ Box 719-025-XX CB25 Inlet Adaptor for 4’x5’ Box (Single) 719-105-XX (24”x24”) Drop Inlet Bot. Slab [40”x40”x6”] 719-105-XX DI (24”x24”) Inlet Adaptor for 4’x4’ box [64”x64”x8”] 719-105-XX DI (24”x24”) Inlet Adaptor for 5’x5’ box [76”x76”x8”] 719-105-XX DI (24”x24”) Inlet Adaptor for 6’x6’ box [88”x88”x8”] 719-110-XX (24”x36”) Drop Inlet Bot. Slab [40”x52”x6”] 719-110-XX DI (24”x36”) Inlet Adaptor for 4’x4’ box [64”x64”x8”] 719-110-XX DI (24”x36”) Inlet Adaptor for 5’x5’ box [76”x76”x8”] 719-110-XX DI (24”x36”) Inlet Adaptor for 6’x6’ box [88”x88”x8”] 719-112-XX DI 112 Bottom Slab [52”x52”x6”] 719-115-XX DI 115 Bottom Slab 719-115-XX DI 115 Top Slab 719-125-XX DI 125 Inlet Adaptor 4’x7’ Box (Single) 719-125-XX DI 125 Inlet Adaptor 4’x5’ Box (Single) 719-330-XX 2’x2’ JB Top 719-330-XX 2’x2.5’ JB Top 719-330-XX 2’x3’ JB Top 719-330-XX 2’x4’ JB Top 719-330-XX 2.5’x2.5’ JB Top 719-330-XX 2.5’x3’ JB Top 719-330-XX 2.5’x4’ JB Top 719-330-XX 3’x3’ JB Top 719-330-XX 3’x4’ JB Top 719-330-XX 3’x5’ JB Top 719-330-XX 3’x6’ JB Top 719-330-XX 4’x4’ JB Top 719-330-XX 4’x5’ JB Top 719-330-XX 4’x6’ JB Top 719-330-XX 5’x5’ JB Top 719-330-XX 5’x6’ JB Top 719-330-XX 6’x6’ JB Top 719-330-XX 4’x4’ Shallow Junction Box Top [64”x64”x8”] 719-330-XX 5’x5’ Shallow Junction Box Top [76”x76”x8”] 719-330-XX 6’x6’ Shallow Junction Box Top [88”x88”x8”] 719-335-00 Spring Box [28”x28”x36”] 719-335-00 Spring Box [28”x28”x42”] 719-335-00 Spring Box [28”x28”x48”] 719-335-00 Spring Box [28”x28”x54”] 719-335-00 Spring Box [28”x28”x60”] 719-335-00 Spring Box Cover [40”x40”x6”] 719-420-00 48” dia. Circular Drainage Base 719-420-00 60” dia. Circular Drainage Base 719-420-00 72” dia. Circular Drainage Base 719-420-00 84” dia. Circular Drainage Base

Form: QPL14DS Precast Concrete Drainage Items – Qualified Product List 14 Certification Letter (3/5)

719-420-00 96” dia. Circular Drainage Base 719-420-00 120” dia. Circular Drainage Base 719-420-00 48” dia. Circular Riser 719-420-00 60” dia. Circular Riser 719-420-00 72” dia. Circular Riser 719-420-00 84” dia. Circular Riser 719-420-00 96” dia. Circular Riser 719-420-00 120” dia. Circular Riser 719-420-00 60” dia. to 48” dia. Circular Transition Slab 719-420-00 72” dia. to 48” dia. Circular Transition Slab 719-420-00 84” dia. to 48” dia. Circular Transition Slab 719-420-00 96” dia. to 48” dia. Circular Transition Slab 719-420-00 120” dia. to 48” dia. Circular Transition Slab 719-420-00 60” dia. to 48” dia. Circular Transition Cone 719-420-00 72” dia. to 48” dia. Circular Transition Cone 719-425-XX Flat Slab Adaptor for 48” dia. Drainage Structure [64”x64”x6”] 719-425-XX Flat Slab Adaptor for 60” dia. Drainage Structure [76”x76”x7”] 719-425-XX Flat Slab Adaptor for 72” dia. Drainage Structure [84” dia.] 719-425-XX Flat Slab Adaptor for 84” dia. Drainage Structure [98” dia.] 719-425-XX Flat Slab Adaptor for 96” dia. Drainage Structure [112” dia.] 719-425-XX Flat Slab Adaptor for 120” dia. Drainage Structure [140” dia.] 719-505-XX Manhole PC Bottom Slab [100”dia.x6”] 719-505-XX Manhole PC Eccentric Cone 719-505-XX Manhole Inlet Adaptor for 4’x4’ box [64”x64”x8”] 719-505-XX Manhole Inlet Adaptor for 5’x5’ box [76”x76”x8”] 719-505-XX Manhole Inlet Adaptor for 6’x6’ box [88”x88”x8”] 719-605-00 Straight Headwall Single Pipe 15” dia max [39”x20”x63”] 719-605-00 Straight Headwall Single Pipe 18” dia max [42”x21”x66”] 719-605-00 Straight Headwall Single Pipe 24” dia max [48”x24”x72”] 719-605-00 Straight Headwall Single Pipe 30” dia max [54”x26”x78”] 719-605-00 Straight Headwall Single Pipe up to 36” dia max [60”x27”x84”] 719-605-00 Straight Headwall Single Pipe 42” dia max [66”x29”x102”] 719-605-00 Straight Headwall Single Pipe 48” dia max [72”x36”x108”] 719-605-00 Straight Headwall Single Pipe 54” dia max [78”x38”x126”] 719-605-00 Straight Headwall Single Pipe up to 60” dia max [84”x39”x132”] 719-605-00 Straight Headwall Multiple Pipes 15” dia max [39”x20”xM”] 719-605-00 Straight Headwall Multiple Pipes 18” dia max [42”x21”xM”] 719-605-00 Straight Headwall Multiple Pipes 24” dia max [48”x24”xM”] 719-605-00 Straight Headwall Multiple Pipes 30” dia max [54”x26”xM”] 719-605-00 Straight Headwall Multiple Pipes up to 36” dia max [60”x27”xM”] 719-605-00 Straight Headwall Multiple Pipes 42” dia max [66”x29”xM”] 719-605-00 Straight Headwall Multiple Pipes 48” dia max [72”x36”xM”] 719-605-00 Straight Headwall Multiple Pipes 54” dia max [78”x38”xM”]

Form: QPL14DS Precast Concrete Drainage Items – Qualified Product List 14 Certification Letter (4/5)

719-605-00 Straight Headwall Multiple Pipes up to 60” dia max [84”x39”xM”] 719-615-00 Pipe End Structure up to 18” Pipe@ 4:1 Slope [123”x48”x40”] 719-615-00 Pipe End Structure up to 36” Pipe@ 4:1 Slope [222”x68”x60”] 719-615-00 Pipe End Structure up to 54” Pipe@ 4:1 Slope [294”x92”x84”] 719-615-00 Pipe End Structure up to 72” Pipe@ 4:1 Slope [396”x112”x104”] 719-615-00 Pipe End Structure up to 18” Pipe@ 6:1 Slope [195”x48”x40”] 719-615-00 Pipe End Structure up to 36” Pipe@ 6:1 Slope [301”x68”x60”] 719-615-00 Pipe End Structure up to 54” Pipe@ 6:1 Slope [442”x92”x84”] 719-615-00 Pipe End Structure up to 72” Pipe@ 6:1 Slope [577”x112”x104”] 722-305-00* PC Box Culvert (WxH) [2x2] 722-305-00* PC Box Culvert (WxH) >[2x2] to [4x4] 722-305-00* PC Box Culvert (WxH) >[4x4] to [6x6] 722-305-00* PC Box Culvert (WxH) >[6x6] to [8x8] 722-305-00* PC Box Culvert (WxH) >[8x8] to [10x10] 722-305-00* PC Box Culvert (WxH) >[10x10] to [12x12] 722-305-00* PC Box Culvert larger than [12x12]

Form: QPL14DS Precast Concrete Drainage Items – Qualified Product List 14 Certification Letter (5/5)

802-105-00 Underdrain End Protector for 6” PVC on 2:1 Slope [36”x18”x4”] 802-105-00 Underdrain End Protector for 6” PVC on 4:1 Slope [43.75”x18”x4”] 802-105-00 Underdrain End Protector for 6” PVC on 6:1 Slope [54.5”x18”x4”] 802-105-00 Underdrain End Protector for 4” PVC on 2:1 Slope [36”x16”x4”] 802-105-00 Underdrain End Protector for 4” PVC on 4:1 Slope [36”x16”x4”] 802-105-00 Underdrain End Protector for 4” PVC on 6:1 Slope [40.5”x16”x4”]

* Box culvert sizes will be listed for general reference with a note directing contractors to verify that a manufacturer can make specific culvert sizes for each project.

Drainage boxes & risers shown on Standard Drawing 719-305-00, 719-310-00, & 719-315-00 require full engineering submittal as described on the drawing. Precast Reinforced Concrete Floorless Culverts previous project engineering submittal.

SCDOT Standard Drawings are available on our website at:

www.scdot.org/doing/sd_book.shtml

I certify that the items (checked above) to be produced (by the company listed on the top of each certification form) for the South Carolina Department of Transportation, shall comply with the latest revision of SCDOT Standard Drawing (current at the time each item is fabricated.)

(Sign & Date)

(Print Name)

Please return this certification form to: Or by email: d8designstandards@scdot.org Design Standards Office Or by fax: (803) 737-0608 Preconstruction Support 955 Park Street Room 409 Columbia, SC 29201 http://www.scdot.org/doing/sd_book.shtml

Form: QPL14FC Request to Supply Precast Reinforced Concrete Floorless Culverts

Precast Reinforced Concrete Floorless Culvert Manufacturers shall use this request form to have their contact information placed on Qualified Product List #14. This list is to assist contractors in finding available products and does not indicate SCDOT design approval. Manufacture facilities shall be inspected as required by the Department and floorless culvert designs submitted for each project shall be reviewed as required by the Department. Submit this form and 2 examples for EACH floorless culvert type you wish to produce.

Trademark or Product Name _____________________

Web Page _____________________

Company _____________________

Street Address _____________________

City _____________________

State _____________________

Zip Code _____________________

Contact Person _____________________

Phone Number _____________________

Email Address _____________________

Minimum Manufactured Span _____________________

Maximum Manufactured Span* _____________________

Type: Arch, Flat Slab, Arch Box Arch – The arch floorless culvert system consists of a continuously curved barrel.

Flat Slab – The flat slab floorless culvert system consists of a top flat slab supported by two vertical walls.

Arch Box – The arch box floorless culvert system consists of a curved top slab supported by two vertical walls.

* Maximum Manufactured Span must be within 20% of the span of the largest submitted as built or tested design up to 48’ fabricated span.

For ALL spans larger than 48’, manufacturer must demonstrate prior successful installation or full scale load testing including fabrication and handling loads of a floorless culvert as large as, or larger, than the requested span.

Please submit this form, and all required information listed in section 4.0 of this document at least

45 business days prior to needing the floorless culvert for a project to:.

Design Standards Office Or by email: d8designstandards@scdot.org Preconstruction Support Or by fax: (803) 737-0608 955 Park Street Room 409 Columbia, SC 29201

File details come from the government source that posted it. Updated .