The file's text, extracted by GovTribe without its formatting.
CHECKLIST FOR INSPECTION OF HYDRAULIC ELEVATORS
GENERAL NOTES:
(a) See ASME A17.2 - 2010 for detailed Code requirements.
(b) OK = meets requirements; NG = no good; NA = not applicable.
Address:
Periodic Inspection
Periodic Test – Cat-1
Periodic Test – Cat-3
Periodic Test – Cat-5
Acceptance Evaluation/Test
| Passenger | |
| Rated load: | lbs. |
| Inspected by: | |
| Date: | |
| Freight class: | |
| Rated speed: | fpm |
| QEI No: | |
| Certifying Organization: | |
Signature:
| 1 |
| INSIDE OF CAR |
| 2.32 |
| Control valve |
| 1.1 |
| Door reopening device |
| 2.34 |
| Flexible hose and fitting assemblies |
| 1.3 |
| Operating control devices |
| 2.35 |
| Supply line and shutoff valve |
| 1.5 |
| Car lighting and receptacles |
| 2.38 |
| Roped water hydraulic |
| 1.9 |
| Power closing of doors or gates |
| 1.10 |
| Power opening of doors or gates |
| 2.42 |
| Earthquake inspection/test |
| 1.11 |
| Car vision panels and glass car doors |
| 3.1 |
| Top-of-car stop switch |
| 3.2 |
| Car top light and outlet |
| 3.3 |
| Top-of-car operating device |
| 1.15 |
| Signs and operating device symbols |
| 3.4 |
| Top-of-car clearance and refuge space |
| 1.16 |
| Rated load, platform area, and data plate |
| 3.5 |
| Normal terminal stopping device |
1.17
Standby power operation
3.6 Final and emergency terminal stopping devices
1.18 Restricted opening of car or hoistway doors
3.7
Car-leveling and anti-creep devices
1.20
Earthquake inspection/test
3.9 Floor and emergency identification numbering
| 2 |
| MACHINE ROOM |
| 3.10 |
| Hoistway construction |
| 2.1 |
| Access to machine space |
| 3.11 |
| Hoistway smoke control |
| 3.12 |
| Pipes, wiring, and ducts |
| 2.3 |
| Lighting and receptacles |
| 3.13 |
| Windows/projections/recesses/setbacks |
| 3.16 |
| Traveling cables and junction box |
| 3.17 |
| Door and gate equipment |
| 2.8 |
| Pipes, wiring, and ducts |
| 3.18 |
| Car frame and stiles |
| 2.9 |
| Guarding of exposed auxiliary equipment |
| 3.19 |
| Guide rails fastening and equipment |
2.10 Numbering of elevators, machines, and disconnect switches
3.20
Governor rope
| 2.11 |
| Disconnecting means and control |
| 3.21 |
| Governor releasing carrier |
| 2.12 |
| Controller wiring, fuses, grounding, etc. |
| 3.22 |
| Wire rope fastening and hitch plate |
| 2.13 |
| Governor, overspeed switch and seal |
| 3.27 |
| Crosshead & rope data tags |
| 3.28 |
| Counterweight & buffer |
| 2.30 |
| Hydraulic power unit |
| 3.29 |
| Counterweight safeties |
CHECKLIST FOR INSPECTION OF HYDRAULIC ELEVATORS (Back)
| 5.1 |
| Pit access/lighting/stop switch/condition |
| 5.2 |
| Bottom clearance/runby/refuge space |
| 3.34 |
| Earthquake inspection/test |
| 5.4 |
| Normal terminal stopping device |
| 4 |
| OUTSIDE HOISTWAY |
| 5.5 |
| Traveling cables |
| 5.6 |
| Governor rope tension device |
| 5.7 |
| Car frame and platform |
| 5.8 |
| Car/CW safeties and guiding members |
| 4.4 |
| Hoistway door locking device |
| 5.11 |
| Plunger and cylinder |
| 4.6 |
| Power closing of hoistway doors |
| 4.9 |
| Elevator parking device |
| 5.16 |
| Earthquake inspection/test |
| 4.10 |
| Emergency doors in blind hoistways |
| 4.12 |
| Standby power selection switch |
The above checklist form
ASME
A050C7, has been computer enhanced by
Continental
Hoisting
Consultants, Inc.
The original
A050C7 may be obtained from
ASME
Order
Dept., Law
Drive, Box
2300, Fairfield, NJ
07007-2300
1.800.843.2763
PERFORMANCE DATA
| Make: | | |
| Installation date: | | |
| # of landings: | | |
| # of openings: | F | R |
| Door entrance type: | | | |
| Door entrance size: | in | X | in |
| Typical floor rise: | ft | | |
| ACTUAL SPEED: |
| EMPTY |
| FULL |
| REMARKS |
Up - FPM (feet per minute)
Down - FPM (feet per minute)
PERFORMANCE TIMES: Time from start of door closing to doors open 32 in. (813mm) at adjacent floor.
Up (1) – Seconds
Down (1) – Seconds
MOTION TIME: Start to stop.
Up (1) – Seconds
Down (1) – Seconds
| DOOR TIMES: Full open to full close – sec. |
| FRONT |
| REAR |
| REMARKS |
Door Open
Door Close
Long (hall call) Dwell
Short (car call) Dwell
Detector (door ray) Hold
Nudging (Time/closing speed/closing force)
Closing Pressure (between 1/3 & 2/3) - max. 30 lbf.
| GFR-CAR RIDE QUALITY: g-force rate |
| EMPTY |
| OPTIMAL RANGE |
| REMARKS |
Start
UP
Accel
UP
Decel
UP
Stop
UP
Jerk
UP
ROPE DATA
LOCATION OF ROPES
MATERIALS
NUMBER
| SIZE AND CONSTRUCTION |
| USED LIFE |
(in months)
EST. LIFE
(in months)
REMARKS
HOIST
GOVERNOR
SAFETY TEST DATA
| Category 1 Test Date: |
| Category 3 Test Date: |
| Category 5 Test Date: |
| Car Safety Device Type: |
Maintenance Provider:
Copyright © Continental Hoisting Consultants, Inc. 1997-Revised 2012