The file's text, extracted by GovTribe without its formatting.
CHECKLIST FOR INSPECTION OF ELECTRIC ELEVATORS
GENERAL NOTES:
(a) See ASME A17.2 – 2010 for detailed Code requirements.
(b) OK = meets requirements; NG = no good; NA = not applicable.
Address:
Periodic Inspection
Periodic Test – Cat 1
Periodic Test – Cat 5
Acceptance Inspection/Test
| Passenger | |
| Rated load: | lbs. |
| Inspected by: | |
| Date: | |
| Freight Class: | |
| Rated speed: | fpm |
| QEI No: | |
| Certifying Organization: | |
Signature:
| 1 |
| INSIDE OF CAR |
| 2.19 |
| Gears, bearings and flexible couplings |
1.1
Door reopening device
2.20 Winding drum machine and slack cable device
| 2.21 |
| Belt or chain-drive machine |
| 1.3 |
| Operating control devices |
| 2.23 |
| Absorption of regenerated power |
| 1.5 |
| Car lighting and receptacles |
| 2.24 |
| AC drives from a DC source |
| 2.26 |
| Secondary and deflector sheaves |
| 1.9 |
| Power closing of doors or gates |
| 2.28 |
| Terminal stopping devices |
| 1.10 |
| Power opening of doors or gates |
| 2.29 |
| Car and counterweight safeties |
| 1.11 |
| Car vision panels and glass car doors |
| 2.42 |
| Earthquake inspection/test |
| 3.1 |
| Top-of-car stop switch |
| 1.15 |
| Signs and operating device symbols |
| 3.2 |
| Car top light and outlet |
| 1.16 |
| Rated load, platform area, and data plate |
| 3.3 |
| Top-of-car operating device |
| 1.17 |
| Standby power operation |
| 3.4 |
| Top-of-car clearance and refuge space |
| 1.18 |
| Restricted opening of car/hoistway doors |
| 3.5 |
| Normal terminal stopping device |
1.19
Car ride
3.6 Final and emergency terminal stopping devices
| 1.20 |
| Earthquake inspection/test |
| 3.7 |
| Car leveling and anti-creep devices |
| 2 |
| MACHINE ROOM |
| 3.8 |
| Top emergency exit |
| 2.1 |
| Access to machine space |
| 3.9 |
| Floor, and emergency numbering |
| 3.10 |
| Hoistway construction |
| 2.3 |
| Lighting and receptacles |
| 3.11 |
| Hoistway smoke control |
| 3.12 |
| Pipes, wiring, and ducts |
| 3.13 |
| Windows/projections/setbacks/recesses |
| 2.8 |
| Pipes, wiring, and ducts |
| 3.16 |
| Traveling cables and junction boxes |
| 2.9 |
| Guarding of exposed auxiliary equipment |
| 3.17 |
| Door and gate equipment |
2.10 Numbering of elevators, machines, and disconnect switches
3.18
Car frame and stiles
| 2.11 |
| Disconnecting means and control |
| 3.19 |
| Guide rails, fastening and equipment |
| 2.12 |
| Controller wiring, fuses, grounding, etc. |
| 2.13 |
| Governor, overspeed switch, and seal |
| 3.21 |
| Governor releasing carrier |
| 3.22 |
| Wire rope fastening and hitch plate |
| 2.16 |
| Overhead beam and fastenings |
| 3.24 |
| Top counterweight clearance |
| 3.25 |
| Car, overhead, and deflector sheaves |
| 2.18 |
| Traction drive machines |
| 3.26 |
| Broken rope, chain, or tape switch |
CHECKLIST FOR INSPECTION OF ELECTRIC ELEVATORS (Back)
| 3.27 |
| Crosshead data plate |
| 4.12 |
| Standby power selection switch |
| 3.28 |
| Counterweight/counterweight buffer |
| 3.29 |
| Counterweight safeties |
| 3.33 |
| Compensating ropes and chains |
| 5.1 |
| Pit access/lighting/stop switch/condition |
| 3.34 |
| Earthquake inspection/test |
| 5.2 |
| Bottom clearance/runby/refuge space |
| 4 |
| OUTSIDE HOISTWAY |
| 5.3 |
| Final/Em. terminal stopping devices |
| 5.4 |
| Normal terminal stopping devices |
| 5.6 |
| Governor-rope tension devices |
| 4.4 |
| Hoistway door locking devices |
| 5.7 |
| Car frame and platform |
| 5.8 |
| Car safeties and guiding members |
| 4.6 |
| Power closing of hoistway doors |
| 5.9 |
| Buffers/Em. terminal speed devices |
| 5.10 |
| Compensating ropes/chains/sheaves |
| 5.16 |
| Earthquake inspection/test |
| 4.9 |
| Elevator parking devices |
| 4.10 |
| Emergency doors blind hoistway |
| 4.11 |
| Separate counterweight hoistway |
The above checklist form ASME A134C1, has been computer enhanced by Continental Hoisting Consultants, Inc. The original A134C1 may be obtained from ASME Order Dept., 22 Law Drive, Box 2300, Fairfield, NJ 07007-2300 – 1.800.843.2763
PERFORMANCE DATA
| Make: | | |
| Installation date: | | |
| # of landings: | | |
| # of openings: | F | R |
| Door entrance type: | | | |
| Door entrance size: | in | X | in |
| Typical floor rise: | ft | | |
| ACTUAL SPEED: |
| EMPTY |
| FULL |
| REMARKS |
Up – FPM (feet per minute)
Down – FPM (feet per minute)
PERFORMANCE TIMES: Time from start of door closing to doors open 32 in. (813mm) at adjacent floor.
Up (1) – Seconds
Down (1) – Seconds
MOTION TIME: Brake to brake
Up (1) – Seconds
Down (1) – Seconds
| DOOR TIMES: Full open to full close – sec. |
| FRONT |
| REAR |
| REMARKS |
Door open
Door close
Long (hall call) dwell
Short (car call) dwell
Detector (door ray) hold
Nudging (Time/closing speed/closing force)
Closing pressure (between 1/3 & 2/3) – max. 30 lbf.
| GFR-CAR RIDE QUALITY: g-force rate |
| EMPTY |
| OPTIMAL RANGE |
| REMARKS |
Start
UP
Accel
UP
Decel
UP
Stop
UP
Jerk
UP
ROPE DATA
LOCATION OF ROPES
MATERIALS
NUMBER
| SIZE AND CONSTRUCTION |
| USED LIFE |
(in months)
EST. LIFE
(in months)
REMARKS
Hoist
Governor – Car
Compensation
Governor – Counterweight
Car Counterweight
Drum Counterweight
Safety
SAFETY TEST DATA
| Category 1 test date: |
| Category 5 test date: |
| Car safety type: |
| Counterweight safety type: |
Maintenance Provider:
Copyright © Continental Hoisting Consultants, Inc. 1997–Revised 2012 “Elevator Safety Is No Accident”