This document is a California State Bid Specification for Red Fusees (emergency highway traffic warning signals), specifically identified as Bid Specification #1390-5106, Revision 0, dated January 15, 2020. The specification is developed by the State of California and involves the procurement of emergency highway warning devices, with involvement from the California Department of Transportation and the Office of the State Fire Marshal.
The bid specification details technical requirements for red fusees without spikes, available in 15, 20, and 30-minute rated burn times. Key requirements include UL 912 compliance, approval by the California State Fire Marshal, mandatory anti-rolling features, no metal parts, and prohibition of potassium perchlorate. The fusees must pass specific testing protocols, including an anti-roll test on a concrete or asphalt surface with a 10-degree incline, where the device must not roll or slide more than 24 inches upon impact. Manufacturers must submit third-party testing reports verifying compliance with these stringent specifications, and each fusee must be clearly marked with manufacture date, usage instructions, and the state fire marshal's approval seal.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Attachment_A_-_Contract_Pricing,_Supplement_4.xlsx | XLSX spreadsheet | |
| Attachment_C_-_CA_Igniter_Flares_Specifications_2020.doc | DOC document | |
| Contract_User_Instructions_-_Supp_9.docx | DOCX document | |
| Attachment_D_-_UL_912_updated_May_2018.pdf | ||
| Attachment_E_-_MICA_Exhibit_3.0.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Document Summary
| Detail Type |
| Detail |
| Event ID |
| 0000011720 |
| Commodity |
| Fusees, Red (without spikes) 15, 20, and 30 Minute |
| Attachment |
| 2 |
| Group-Class |
| 1390 |
| Bid Specification |
| 1390-5106 |
| Revision Level |
| 0 |
| Revision Date |
| Jan 15, 2020 |
| Agency Name |
| Statewide |
Revision History
| Bid Spec |
| Rev Level |
| Revision Date |
| Author |
| Summary of Changes |
| 1390-2677A |
| 0 |
| July 30, 2014 |
| Wong, N. Tarn, J. |
| Bid development |
| 1390-5106 |
| 0 |
| Jan 15, 2020 |
| Lai, Y. Velazquez, I. |
| Update Section 4.0 QUALITY ASSURANCE PROVISIONS |
State of California Bid Specification Fusees, Red (without spikes) Attachment B
#1390-5106 REV 0 1/15/2020
15, 20, and 30 Minute
Lai, Y.; Velazquez, I.
Jan 15, 2020
Table of Contents
| Document Summary | 1 | |
| Revision History | 1 | |
| Table of Contents | 2 | |
| 1.0 | SCOPE | 3 |
| APPLICABLE LAWS and INDUSTRY STANDARDS | 3 | |
| LAWS and REGULATIONS | 3 | |
| INDUSTRY STANDARDS | 3 | |
| TECHNICAL REQUIREMENTS | 3 | |
| GENERAL | 3 | |
| WORKMANSHIP | 3 | |
| SPECIAL MARKINGS | 3 | |
| QUALITY ASSURANCE PROVISIONS | 4 | |
| STATE ANTI-ROLL TEST REQUIREMENT | 4 | |
| PERCHLORATE TEST | 4 |
1.0 SCOPE
This specification covers red fusees (without spikes) intended to be carried on automotive vehicles for use as emergency highway traffic warning signals.
2.0 APPLICABLE LAWS and INDUSTRY STANDARDS
Specifications, standards and regulations referenced in this document in effect on the opening of the invitation for bid, form a part of this specification.
2.1 LAWS and REGULATIONS None listed
2.2 INDUSTRY STANDARDS
2.2.1 Underwriters Laboratories Standard (UL) 912 Highway Emergency Signals, latest edition, Sections 24 through 35.
3.0 TECHNICAL REQUIREMENTS
3.1 GENERAL
3.1.1 Specified rated time for each fusee shall be either 15, 20, or 30 minutes.
3.1.2 The fusees shall conform in all respects to the requirements of Underwriters Laboratories Standard (UL) 912 Highway Emergency Signals, latest edition Sections 24 through 35 for fusees as well as conform to the additional requirements of this specification.
3.1.3 The fusees shall be approved for sale and use in the state of California by the Office of the State Fire Marshal.
3.1.4 The fusees shall have an anti-rolling feature that shall meet the test requirements in Section 4.1 of this bid specification. This feature shall not create excess bulk such as to require additional storage space.
3.1.5 There shall be no metal parts used in the fusees.
3.1.6 The fusees shall contain no potassium perchlorate.
3.2 WORKMANSHIP
The fusees shall be free from defects that will affect the safety, appearance, or serviceability.
3.3 SPECIAL MARKINGS
In addition to marking required by UL 912 Section 35, each fusee shall be marked with instruction for use of the anti-roll device, date (month and year) of manufacture, and the California State Office of the State Fire Marshal's seal of approval. Markings should also include, "Does Not Contain Potassium Perchlorate". All markings shall be legible.
4.0 QUALITY ASSURANCE PROVISIONS
A third party or manufacturer report for the anti-roll test and perchlorate test shall be submitted with the bid.
4.1 STATE ANTI-ROLL TEST REQUIREMENT
The test surface shall be concrete or asphalt with a road surface roughness range from 0.3 to 0.5 coefficient of friction as determined by the California Department of Transportation Test 342 (Typical Road Surface). The test surface shall not be perceptibly out of flat and shall be at a 10° incline ±2° from the horizontal. The fusee shall be ignited per manufacturer’s recommended user instructions and dropped from knee height of 20±3 inches and shall not roll or slide more than 24 inches from the point of impact.
4.2 PERCHLORATE TEST
The fusee shall be tested for potassium perchlorate per UL 912, 34A.
Note: California requires potassium perchlorate free fusee, there shall be no violet precipitate produced by the reaction of the test.