Attachment A- Stafford FR-8 100 CD BID SET_Part3.pdf
PDF 38 MB Posted
- Attached to
- IFB 26141 - Fire & Rescue Station 8
- Solicitation number
- IFB-122139
- Issued by
- Stafford County, Virginia
About this file
This is Attachment A, Part 3 of a bid set document for Stafford County Fire & Rescue Station 8 in Rock Hill, Virginia, prepared under Invitation for Bid (IFB) 26141. The document supports the construction of a new Fire & Rescue Station 8 facility and is restricted to bidders who have been prequalified under RFQu 26073. The bid set outlines specific construction requirements, technical specifications, and project parameters that bidders must address in their proposals. Bidders are required to meet all prequalification criteria before submitting bids, ensuring that only qualified contractors participate in the competitive bidding process for this public safety infrastructure project.
The document establishes detailed specifications and requirements that govern the construction scope, materials, labor standards, and deliverables associated with the Fire & Rescue Station 8 project. This restriction to prequalified bidders serves as a set-aside mechanism to maintain quality and capability standards for public safety facility construction. As part of a larger bid package, this attachment functions as a technical reference document that bidders must comply with when developing their proposals, pricing, and project execution plans.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
FACE
FACE
F A
C E
E
F A
C E
G
MEZZANINE
TRAINING
SCBA
STORAGE
MECHANICAL/
COMPRESSOR
A102 1B1D
1C
1A
A102
2A
2B
2C
2D
9' - 8 3/8" 11' - 4"
APPARATUS
STORAGE
A710
F A
C E
D.3
F A
C E
D.4
F A
C E
D.8
F4 F5
C L
E A
R
0 M6 G
S8
S8
0 M8 G
0 M8 D
0 M6 D
0 M8 D
F15
0 M12 G
0 M8
0 M8 G
F15
F4 F15
F4F15 F15
Architecture Interior Design Landscape Architecture Engineering
TRUE NORTH PLAN NORTH
1054 31st Street NW Canal Square Suite 410 Washington, DC 20007 202.595.3173 www.bkvgroup.com
© 2021 BKV Group
SHEET NUMBER
SHEET TITLE
DRAWN BY
CHECKED BY
COMMISSION NUMBER
PROJECT TITLE
CONSULTANTS
CERTIFICATION
KEYPLAN
A u to d e s k D o c s /2
.0
S ta ff o rd
F ir e -R e s c u e
S ta ti o n -8
/2
-0
F
R -8
A
I_
.r v t
/8
/2
:0
:1
P
M
B.Adams
M.Manetti
2540.03
A102
MEZZANINE PLAN
STAFFORD
COUNTY FIRE &
RESCUE
STATION 8 -
ROCK HILL
B
A
C D
A102 1/4" = 1'-0"
1 MEZZANINE LEVEL
A102 3/16" = 1'-0"
1A SCBA STORAGE ELEV 1A
A102 3/16" = 1'-0"
1C SCBA STORAGE ELEV 1C
A102 3/16" = 1'-0"
1D SCBA STORAGE ELEV 1D
A102 3/16" = 1'-0"
2D MECH STOR ELEV 2D
A102 3/16" = 1'-0"
2A MECH STOR ELEV 2A
A102 3/16" = 1'-0"
2B MECH STOR ELEV 2B
A102 3/16" = 1'-0"
2C MECH STOR ELEV 2C
A102 3/16" = 1'-0"
1B SCBA STORAGE ELEV 1B
SCHEDULE - EQUIPMENT MASTER
No. Description Manuf. Model Notes Prov. Qty.
10 00 00 Miscellaneous Specialties
S8 WIRE SHELVING Metro Erecta 1860C-46 CFCI 2
11 96 00 Fire Station Equipment
F4 AIR COMPRESSOR Gardener Denver VR05PURVS-8 CFCI 1
F5 COMPRESSED AIR DRYER Ingersol Rand D85EC CFCI 1
F11 WALL MOUNTED TIE DOWN Guardian 00600-CB-1-B CFCI 4
F15 SCBA COMPRESSOR BAUER VTC-7K/20 1 OFCI 1
KEYNOTES - ARCHITECTURAL
FLOOR PLAN GENERAL NOTES
1. GENERAL NOTES APPLY TO ALL DRAWING SHEETS.
2. DO NOT SCALE THE DRAWINGS. WHERE DIMENSIONS ARE NOT PROVIDED OR ARE UNCLEAR,
REQUEST CLARIFICATION FROM THE ARCHITECT.
3. VERIFY ALL EXISTING CONDITIONS, DIMENSIONS, AND ELEVATIONS. NOTIFY THE ARCHITECT OF ANY
DISCREPANCIES UPON DISCOVERY.
4. ALL WORK SHALL BE DONE IN ACCORDANCE WITH LOCAL BUILDING CODES. COMPLIANCE WITH ALL
APPLICABLE CODES WILL BE REQUIRED TO BE MET OR EXCEEDED.
5. REFER TO REFLECTED CEILING PLANS FOR CEILING HEIGHTS AND CEILING FINISHES.
6. REFER TO CODE PLANS FOR LOCATIONS OF RATED WALLS, SMOKE BARRIERS, FIRE EXTINGUISHER
CABINETS, ETC.
7. REFER TO INTERIOR FINISH PLANS AND ROOM FINISH SCHEDULE FOR ROOM FINISHES.
8. REFER TO INTERIOR FURNITURE PLANS FOR FURNITURE/FIXTURE LAYOUT.
9. REFER TO SHEET G140 FOR TYPICAL MOUNTING ELEVATIONS.
10. ARCHITECTURAL FINISHED FLOOR ELEVATIONS ARE TO TOP OF CONCRETE SLAB OR TOPPING.
11. UNLESS NOTED OTHERWISE, ALL NON-RATED INTERIOR WALLS SHALL BE TYPE "S4", EXTENDING UP
TO UNDERSIDE OF FLOOR OR ROOF ABOVE WITH MINERAL WOOL ACOUSTIC BATT INSULATION.
SCRIBE GYPSUM BOARD TO IRREGULARITIES OF DECK ABOVE AND SEAL AROUND ALL
PENETRATIONS WITH ACOUSTIC SEALANT.
12. PLAN DIMENSIONS ARE TO FINISHED SURFACE OF MASONRY WALLS, OR CENTERLINE OF STUDS AT
METAL STUD INTERIOR WALLS, UNLESS NOTED OTHERWISE. REFER TO SHEET A602
CONSTRUCTION ASSEMBLY TYPES FOR MORE INFORMATION.
13. COORDINATE ALL LOCATIONS FOR IN-WALL BLOCKING AND/OR WALL BACKING FOR ITEMS SUCH AS
TOILET ACCESSORIES, GRAB BARS, CASEWORK, WALL-MOUNTED FIXTURES, MARKER BOARDS,
VISUAL DISPLAY BOARDS, AUDIO-VISUAL EQUIPMENT, HANDRAILS, ETC. INSTALL FIRE-RESISTIVE
TREATED WOOD BLOCKING OR METAL BACKING PLATES IN METAL STUD PARTITIONS.
14. TRANSITIONS BETWEEN FINISH FLOOR ELEVATION(S) SHALL NOT EXCEED 1/2 INCH, UNLESS NOTED
OTHERWISE.
15. PROVIDE 4 INCH HIGH CONCRETE HOUSEKEEPING PADS BELOW ALL FLOOR-MOUNTED INTERIOR MECHANICAL AND ELECTRICAL EQUIPMENT. VERIFY EXACT SIZES AND LOCATIONS WITH AFFECTED
TRADES.
16. CONTRACTOR SHALL COORDINATE ALL REQUIRED FLOOR/WALL/ROOF PENETRATION SIZES AND
LOCATIONS WITH ASSOCIATED TRADES PRIOR TO CUTTING.
17. CONTRACTOR SHALL INSTALL CONTINUOUS PERFORATED DRAIN TILE AROUND THE OUTSIDE
PERIMETER OF BUILDING. REFER TO FOUNDATION DETAILS AND SPECIFICATION FOR MORE
INFORMATION. SEE PLUMBING DRAWINGS FOR SUMP LOCATION.
ISSUE # DATE DESCRIPTION
05/05/2025 DD 35% SUBMISSION
09/04/2025 DD 50% SUBMISSION
12/22/2025 CD 90% SUBMISSION
02/02/2026 BUILDING PERMIT
05/08/2026 CD100% / BID SUBMISSION
masif Line masif Line masif Text Box Mark A. Manetti masif Text Box License Number masif Text Box Date masif Text Box 0401010972 masif Line masif Snapshot masif Snapshot masif Text Box 5/8/2026
FEFEC
FEFEC
FEFEC
FACE
F A
C E
A.1
FACE
FACE
FACE
FACE
FACE
F A
C E
C
F A
C E
D
F A
C E
F
F A
C E
B
F A
C E
E
F A
C E
G
6" / 1'-0"
3" / 1'-0" 3" / 1'-0"
FACE
FACE
RT-A
RT-B
RT-A
COVERED
PATIO
1/4" / 1'-0"
1/4" / 1'-0"
1/4" / 1'-0"
1/4" / 1'-0"
A501
A501
A501
A501
A501
A502
A502
A502
A502
A502
3" / 1'-0"
1/4" / 1'-0"
1/4" / 1'-0"
9 1/2" / 1'-0"9 1/2" / 1'-0"
1/4" / 1'-0"
/4
/4
/4
/4
/4
RT-B
3" / 1'-0"
B.9
A.3
3.1 4.1 4.9
F A
C E
G.1
F A
C E
G.2
FACE
4.8
F A
C E
A
D.2
F A
C E
D.3
F A
C E
D.4
F A
C E
D.8
F A
C E
B.1
A710
ERU-1
ASHP-1
CU-1
R02
R07
R01
RTU-1
RT-A
RT-A
RT-A
RT-A
RT-A
RT-A
RT-B
RT-B
R01
EF-4
VR-CU-1
MAU-2
R17
R17
R17
R17
R02
R01
R15
R15
R16
R18
R18
R18
RT-B
R18
R01
R17R18
G121
G121
R01
R04
R04
R02
R04
R04 R04
R04
R04
R04
R04
R03
R05
R05
R04
R05
A820
A662
A662
A650
1/4" / 1'-0"
1/ 4"
1'
-0
1/4" / 1'-0"
1/ 4"
1'
-0
1/ 4"
1'
-0
1/4" / 1'-0"
1/ 4"
1'
-0
1/4" / 1'-0"
1. DO NOT SCALE DRAWINGS.
2. DETAILS INDICATED ARE TYPICAL FOR ALL SIMILAR ROOFING CONDITIONS UNLESS OTHERWISE
NOTED.
3. SEE ARCHITECTURAL ROOF DETAIL SHEET FRO ROOF DETAILS. INSTALL ROOF IN STRICT
ACCORDANCE TO MANUFACTURER'S REQUIREMENTS.
4. PROVIDE CRICKETS AT HIGH SIDE OF ALL ROOF HATCHES, ROOF EQUIPMENT CURBS, PENTRATION
BOXES, AND OTHER ITEMS THAT IMPACT DRAINAGE FLOW.
5. PROVIDE PRECAST CONCRETE SPLASHBLOCKS AT BOTTOM OF DOWNSPOUTS WHERE DISCHARGING
TO ROOF SURFACE AND WHERE SPECIFIED WHEN DISCHARGING TO GRADE.
6. DO NOT INSTALL MECHANICAL EQUIPMENT REQUIRING MAINTENANCE SUCH AS ROOFTOP UNITS, EXHAUST FANS, GRAVITY VENTS, ETC... CLOSER THAN 10'-0" FROM ROOF EDGE.
7. MAJOR ROOFTOP EQUIPMENT IS SHOWN ON THIS DRAWING FOR COORDINATION. COORDINATE
WITH MECHANICAL DRAWINGS FOR LOCATIONS OF ALL ROOFTOP EQUIPMENT.
8. ALL ROOFTOP EQUIPMENT EXCLUDING PREFINISHED ITEMS SHALL BE PAINTED.
9. ALL EXPOSED STEEL SHALL BE HOT DIPPED GALVANIZED.
10. COORDINATE WITH MECHANICAL ROOF PLAN FOR LOCATIONS AND TYPES OF MECHANCIAL
EQUIPMENT IDENTIFIED.
GENERAL NOTES- ROOF PLAN
Architecture Interior Design Landscape Architecture Engineering
TRUE NORTH PLAN NORTH
1054 31st Street NW Canal Square Suite 410 Washington, DC 20007 202.595.3173 www.bkvgroup.com
© 2021 BKV Group
SHEET NUMBER
SHEET TITLE
DRAWN BY
CHECKED BY
COMMISSION NUMBER
PROJECT TITLE
CONSULTANTS
CERTIFICATION
KEYPLAN
A u to d e s k D o c s /2
.0
S ta ff o rd
F ir e -R e s c u e
S ta ti o n -8
/2
-0
F
R -8
A
I_
.r v t
/8
/2
:0
:1
P
M
B.Adams
M.Manetti
2540.03
A140
ROOF PLAN
STAFFORD
COUNTY FIRE &
RESCUE
STATION 8 -
ROCK HILL
A140 1/8" = 1'-0"
1 APP BAY ROOF BEARING
KEYNOTES - ROOF PLAN
R01 ROOF DRAIN SYSTEM. COORDINATE WITH PLUMBING DRAWINGS. SEE ROOF DRAIN DETAIL.
R02 OVERFLOW ROOF DRAIN SYSTEM. COORDINATE WITH PLUMBING DRAWINGS AND DAYLIGHT TO EXTERIOR
OF BUILDING WITHIN 3' OF FINISHED GRADE. SEE ROOF DRAIN DETAIL.
R07 ROOF DRAIN SYSTEM. COORD. W/ PLUMB. DWGS. SEE ROOF DETAILS.
R15 6" WIDE PRE-FINISHED METAL GUTTER SYSTEM SLOPED MINIMUM 1/8" PER FOOT TOWARDS DOWNSPOUT.
COORD. W/ ROOF DETAILS.
R16 8" WIDE PRE-FINISHED METAL GUTTER SYSTEM SLOPED MINIMUM 1/8" PER FOOT TOWARDS DOWNSPOUT.
COORD. W/ ROOF DETAILS.
R17 TAPERED INSULATION ROOF CRICKET SLOPED AT 1/4" PER FOOT AWAY FROM PARAPET TO ACHEIVE
POSITIVE DRAINAGE TOWARDS ROOF DRAIN SYSTEM.
R18 PRE-FINISHED METAL COPING SYSTEM. COORD. W/ ROOF DETAILS AND SPEC.
B
A
C D
ISSUE # DATE DESCRIPTION
05/05/2025 DD 35% SUBMISSION
09/04/2025 DD 50% SUBMISSION
12/22/2025 CD 90% SUBMISSION
02/02/2026 BUILDING PERMIT
05/08/2026 CD100% / BID SUBMISSION
MISCELLANEOUS ASSEMBLIES ROOF
Type Mark BKV Description
B1 GALV. STEEL CONCRETE FILLED BOLLARD SYSTEM W/DECORATIVE COVER
G07 EXTERIOR BUILIDNG MOUNTED LETTERING - 48"
R01 ROOF ACCESS LADDER. COORD. W/ ROOF DETAILS AND MISCELLANEOUS METALS SPEC.
R02 ANTENNA MAST. COORDINATE WITH ANTENNA MAST DETAIL & ELEC DWGS.
R03 ROOF ACCESS LADDER. COORD. W/ ROOF DETAILS AND MISCELLANEOUS METALS SPEC.
R04 SNOW RETENTION SYSTEM.
R05 OVERFLOW ROOF SCUPPER SYSTEM.
masif Line masif Line masif Text Box Mark A. Manetti masif Text Box License Number masif Text Box Date masif Text Box 0401010972 masif Line masif Snapshot masif Snapshot masif
F A
C E
A.1
FACE
FACE
FACE
F A
C E
C
F A
C E
D
F A
C E
B
FACE
FACE
5' - 8 3/8"
LOBBY
KITCHEN
DINING
BUNK
BUNK
BUNK
DECON
VEST C
TRAINING
ROOM
OFFICE
STORAGE
ALCOVE
LAUNDRY
ROOM/
JANITOR
PANTRY
112A
PANTRY
112B
PANTRY
112C
PANTRY
112D
VOLUNTEERS'
OFFICE
SHIFT
SUPERVISOR
OFFICE
SHIFT
BUNK
107A CAREER
SUPERVISOR
OFFICE
SUPERVISOR
TOILET/SHWR
CAREER
SUPERVISOR
BUNK
106A
KITCHENETTE
104A
WATCH
OFFICE
CORRIDOR
STORAGE
CLOSET
PUBLIC
TOILET
TRAINING
STORAGE
DAYROOM
B.9
A.3
3.1 4.1 4.9FACE
4.8
F A
C E
A
D.2
F A
C E
B.1
WC-1
FAUX WOOD BEAMS
WC-1
FAUX WOOD
BEAMS
WC-1
FAUX WOOD BEAMS
4" 6' - 4" 6' - 4" 6' - 4" 6' - 4"
4"
E Q
E Q
8' - 0"
GYP-1
11' - 0"
GYP-1
9' - 0"
ACT-1
9' - 0"
ACT-1
9' - 0"
GYP-1
9' - 0"
GYP-1
9' - 0"
GYP-1
9' - 6"
ACT-1
9' - 0"
ACT-1
9' - 0"
ACT-1
9' - 0"
ACT-1
10' - 0"
GYP-1
10' - 4"
ACT-1
9' - 0"
GYP-1
9' - 0"
ACT-1
10' - 0"
GYP-1
10' - 0"
GYP-1
9' - 0"
GYP-1
9' - 0"
GYP-1
9' - 0"
ACT-1
9' - 0"
GYP-1
9' - 0"
GYP-1
11' - 0"
GYP-1
11' - 0"
GYP-1
11' - 0"
GYP-1
9' - 0"
ACT-1
9' - 0"
ACT-1
PT-1PT-1
PT-1
PT-1
PT-1
PT-1
PT-1
PT-1
PT-1
PT-1 PT-1
PT-1
PT-1
PT-1
PT-1PT-1PT-1
SC
S
SC
SC
SC
SC
SC
SC
SC
SC
S
S
S
S
DL
DL
DLDLDL
KLKL
KL
A-XIT
7' - 8 3/8" 7' - 8 3/8" 7' - 7 11/16" 7' - 7 11/16" 1' - 8 5/8"
23' - 1"
CL
2' - 0"
/8
8"
A810
A810
A810
A810
A810
OS
FIRE STATION ALERTING SCOPE
1. STAFFORD COUNTY FIRE STATIONS USE A PROPRIETARY ALERT NOTIFICATION SYSTEM: “WESTNET FIRST
IN”. THE STATION ALERTING SYSTEM WILL BE A TURNKEY DELIVERY THROUGH THE GENERAL
CONTRACTOR. THE GENERAL CONTRACTOR IS TO CONTRACT DIRECTLY WITH WESTNET FOR THIS
TURNKEY DELIVERY, AND INCLUDE PRICING FOR THE FULL DELIVERY OF THE STATION ALERTING SYSTEM IN THEIR BID. THE GENERAL CONTRACTOR IS TO PROVIDE ALL INFRASTRUCTURE REQUIRED TO FACILITATE A FULLY FUNCTIONING STATION ALERTING SYSTEM PER THE WESTNET DRAWINGS INCLUDED
WITH DEVICES TO SUPPORT STATION ALERTING SYSTEM.
A. PROVIDE COMMUNICATIONS RACK REQUIRED TO SUPPORT STATION ALERTING SYSTEM.
2. SCOPE OF WORK UNDER STATION ALERTING TURNKEY DELIVERY:
A. PROVIDE ALL DEVICES INCLUDED ON WESTNET DRAWINGS INCLUDED WITH SPECIFICATIONS AND
REFERENCED ON ARCHITECTURAL AND ELECTRICAL DRAWINGS.
B. PROVIDE UPS REQUIRED FOR POWERING STATION ALERTING SYSTEM.
C. PROVIDE ALL CABLES REQUIRED FOR STATION ALERTING SYSTEM.
D. PROVIDE ALL HOFFMAN BOX REQUIRED FOR STATION ALERTING SYSTEM.
E. PROVIDE ALL INFRASTRUCTURE TO SUPPORT THE WESTNET STATION ALERTING SYSTEM.
INFRASTRUCTURE REQUIREMENTS ARE IDENTIFIED ON THE ELECTRICAL DRAWINGS. THE GENERAL
CONTRACTOR’S ELECTRICAL SUBCONTRACTOR SHALL REVIEW THE WESTNET DRAWINGS INCLUDED
WITH SPECIFICATIONS AND THE ELECTRICAL AND ARCHITECTURAL CONTRACT DRAWINGS.
F. ARCHITECTURAL REFLECTED CEILING PLANS AND INTERIOR ELEVATIONS INDICATE ACTUAL WESTNET
DEVICE LOCATIONS FOR COORDINATION WITH FINISHES AND OTHER BUILDING SYSTEMS.
G. DEVICES LOCATED IN ACOUSTICAL CEILINGS DO NOT REQUIRE BACKBOX.
H. DEVICES LOCATED IN SHEETROCK OR EXPOSED CEILINGS REQUIRE BACKBOXES.
I. FINAL LOCATIONS OF DEVICES SHALL BE DETERMINED AT THE TIME OF INSTALLATION BY THE
CERTIFIED INSTALLER IN CONSULTATION WITH THE STAFFORD COUNTY FIRE & RESCUE DEPARTMENT.
J. COORDINATE WITH SPECIFICATIONS FOR ADDITIONAL ROUGH-IN AND INSTALLATION DETAILS AND
INFORMATION.
K. GC’S ELECTRICAL SUB-CONTRACTOR SHALL VERIFY WALL AND CEILING TYPES AND COORDINATE WITH
WESTNET TO DETERMINE NEED FOR FLUSH OR SURFACE MOUNT INSTALLATION OF EQUIPMENT
SPECIFIED PRIOR TO INSTALLING REQUIRED INFRASTRUCTURE.
L. SATELLITE & SATELLITE CONTROLLER MUST BE VISIBLE FROM SHOWER. GC’S ELECTRICAL SUB-
CONTRACTOR SHALL VERIFY LOCATION IN FIELD PRIOR TO INSTALLING INFRASTRUCTURE.
M. DORM LIGHTS, SATELLIGHT, & OR SATELLIGHT CONTROLLERS NEAR CEILING FANS MUST BE KEPT
CLEAR OF OBSTRUCTIONS & CEILING FANS DUE TO PHOTOSENSITIVE EPILEPSY.
N. PROVIDE 3/4" CONDUIT FOR ALL SYSTEM WIRING UNLESS OTHERWISE NOTED. CONDUIT SHALL BE CONCEALED ON PARTITIONS OR ABOVE THE CEILING. ALL WIRING AND DEVICES TO BE INSTALLED BY
WESTNET CERTIFIED INSTALLER.
O. ALL BACK BOXES ARE TO BE INSTALLED BY THE GENERAL CONTRACTOR’S ELECTRICAL SUB-
CONTRACTOR AND COORDINATED WITH WESTNET FOR COMPATIBILITY WITH WESTNET DEVICES.
P. THE GENERAL CONTRACTOR SHALL ADVISE THE ARCHITECT OF ANY PERCEIVED DISCREPANCIES
BETWEEN THE WESTNET DRAWINGS AND THE ARCHITECTURAL AND ELECTRICAL DRAWINGS FOR
CLARIFICATION AND DIRECTION.
GENERAL NOTES - WESTNET STATION ALERTING SYSTEM
2' X 2' LIGHT FIXTURE. COORD. W/
LIGHTING FIXT. SCHED.
SUSPENDED STEM MTD. FIXTURES.
COORD. W/ LIGHTING FIXT. SCHED.
RECCESED CAN DOWNLIGHT.
COORD. W/ LIGHTING FIXT. SCHED.
LEGEND - RCP
SUSPENDED HI-BAY STEM MTD.
FIXTURES. COORD. W/ LIGHTING FIXT.
SCHED.
CEILING FAN LOCATION. COORD. W/
EQUIPMENT SCHEDULE
RETURN AIR GRILLE. COORD. W/
MECH. DWGS.
SUPPLY AIR DIFFUSER. COORD. W/
MECH. DWGS.
EQ EQ
E Q
E Q
FANS SPEAKER SYSTEM
FANS COLOR INDICATOR
FINISH CLG. HEIGHT
CEILING ASSEMBLY
2' X 2' LIGHT FIXTURE - EMER.
POWER. COORD. W/ LIGHTING FIXT.
SCHED.
SPEAKER
EQ EQ
E Q
E Q
WALL SCONCE. COORD. W/ LIGHTING
FIXT. SCHED.
DOME PENDANT. COORD. W/
LIGHTING FIXT. SCHED.
CEILING ACCESS PANEL -
CONTRACTOR TO CONFIRM ALL
QUANTITIES AND LOCATIONS
SOLID GRAY WALLS INDICATE
PARTITIONS THAT EXTEND UP TO
ROOF OR FLOOR STRUCTURE ABOVE
LEGEND - WESTNET DEVICES
SATELLIGHT
SATELLIGHT CONTROLLER
S
SC
TT TURNOUT TIMER - MEDIUM
HPS
HPA
HIGH-POWERED SPEAKER
HIGH-POWERED AMPLIFIER
ASLF
ALERT STROBE LIGHT
FIXTURE
SP SPEAKER
DL DORM LIGHT
A-XIT
KL
ACTIVE X-IT LIGHT STRIP
KNIGHT LIGHT
OMNI
OMNI DIRECTIONAL
SPEAKER
DORM REMOTE
DIGITAL VOLUME CONTROL
DR
DVC
SW
OUTSIDE SPEAKER AUDIO
MODULE SINGLE
DB
OSA
EB EMERGENCY BUTTON
SPEAKER SWITCH
DOOR BELL
Architecture Interior Design Landscape Architecture Engineering
TRUE NORTH PLAN NORTH
1054 31st Street NW Canal Square Suite 410 Washington, DC 20007 202.595.3173 www.bkvgroup.com
© 2021 BKV Group
SHEET NUMBER
SHEET TITLE
DRAWN BY
CHECKED BY
COMMISSION NUMBER
PROJECT TITLE
CONSULTANTS
CERTIFICATION
KEYPLAN
A u to d e s k D o c s /2
.0
S ta ff o rd
F ir e -R e s c u e
S ta ti o n -8
/2
-0
F
R -8
A
I_
.r v t
/8
/2
:0
:2
P
M
B.Adams
M.Manetti
2540.03
A301A
REFLECTED
CEILING PLAN -
LEVEL 1 AREA A
STAFFORD
COUNTY FIRE &
RESCUE
STATION 8 -
ROCK HILL
B
A
C D
A301A 1/4" = 1'-0"
1 LEVEL 1 - AREA A - REFLECTED CEILING PLAN
GENERAL RCP NOTES
1 DO NOT SCALE DRAWINGS
2 LOCATION OF DEVICES AND EQUIPMENT SHOWN ON DRAWINGS OF OTHER DISCIPLINES ARE SCHEMATIC AND GENERAL. SPECIFIC LOCATIONS OR GUIDELINES INDICATED ON ARCHITECTURAL DRAWINGS SHALL
GOVERN THE LOCATION OF EXPOSED WORK OF ALL TRADES
3 INSTALL SPRINKLER HEADS, SMOKE ALARMS, LIGHT FIXTURES OR OTHER EXPOSED DEVICES AT CENTER OF ACOUSTICAL TILE (WHERE OCCURS), AT CENTER OF SOFFIT (WHERE OCCURS), OR AT CENTER OF ROOM, UNO. IF DIMENSION TO LOCATE A SPECIFIC DEVICE IS GIVEN IN ONE DIRECTION, CONTRACTOR TO
CENTER THE DEVICE ON CEILING OR SOFFIT IN THE OTHER DIRECTION
4 FOR CLARITY, UNDER-CABINET, TASK, AND COVE LIGHTING ARE NOT SHOWN ON THE ARCHITECTURAL RCP. SEE A8 SERIES (INTERIOR ELEVATIONS) AND A9 SERIES (INTERIORS DETAILS) FOR LOCATIONS
5 REMOVE ALL BARCODE, TAGS, ETC. FROM CONDUIT, PIPING AND DUCTWORK PRIOR TO INSTALLATION.
ROTATE PERMANENT MARKINGS TO CONCEAL.
6 CEILING HEIGHTS ARE SHOWN ON THE REFLECTED CEILING PLAN. ALL CEILING HEIGHTS INDICATED ARE
FROM FLOOR ELEVATION IMMEDIATELY BELOW.
7 AT EXPOSED CEILING CONDITIONS, COORDINATE ALL WIRING, CONDUIT, DUCTS, ETC. FOR AN ORGANIZED
FINISHED LOOK
8 REFER TO ELECTRICAL DRAWINGS AND FIRE PROTECTION DRAWING FOR FIXTURE EQUIPMENT TYPE
9 REFER TO MECHANICAL, PLUMBING, ELECTRICAL, AND FIRE PROTECTION DRAWINGS FOR ADDITIONAL
INFORMATION
10 PLACE ALL CEILING MOUNTED EQUIPMENT IN THE CENTER OF THE CEILING TILE UNLESS OTHERWISE
NOTED. COORDINATE ALL DISCREPANCIES WITH ARCHITECT PRIOR TO INSTALLATION
11 SEE INTERIOR ELEVATIONS / SECTIONS / DETAILS FOR ADDITIONAL INFORMATION ON FINISHED SOFFIT, BULKHEAD, CEILING, ETC. WHERE NOT INDICATED ON REFLECTED CEILING PLAN
12 REFER TO ADDITIONAL NOTES AND REQUIREMENTS ON ALL OTHER DOCUMENTS AND OTHER DISCIPLINES
DOCUMENTS
13 PAINT ALL STRUCTURE EXPOSED TO VIEW UNLESS NOTED OTHERWISE. PAINT ALL EXPOSED CONDUIT
PIPE, DUCTWORK, ETC.
14 PAINT ALL GYPSUM BOARD CEILINGS, SEE FINISH SCHEDULE FOR PAINT COLOR
15 CENTER ALL FIXTURES AND DEVICES IN CEILING TILE, UNLESS OTHERWISE NOTED
16 ALL EXIT DEVICES TO BE PENDANT MOUNTED FROM DECK EXCEPT MAIN ENTRY, EXIT SIGN WHICH IS TO BE
WALL MOUNTED AND CENTERED ABOVE DOORS
17 COORDINATE LOCATION OF ALL LIGHT SWITCHES AND THERMOSTATS W/ ARCHITECT AND OWNER PRIOR TO CONSTRUCTION. PROVIDE SHOP DRAWING INDICATING ALL DEVICE LOCATIONS AND PROPOSED
HEIGHTS FOR REVIEW AND APPROVAL.
18 INSTALL MECHANICAL AND PLUMBING WORK TIGHT TO STRUCTURAL ELEMENTS TO MAINTAIN MAXIMUM
CEILING HEIGHT UNLESS NOTED OTHERWIOSE ON DRAWINGS
19 MECHANICAL SHOWN FOR REFERENCE ONLY, REFER TO THE MECHANICAL DRAWINGS FOR:
A. DUCTWORK, AIR MOVEMENT REQUIREMENTS; SIZES OF GRILLES, DIFFUSERS AND REGISTERS
20 LIGHT FIXTURES SHOWN FOR REFERENCE ONLY. REFER TO THE ELECTRICAL DRAWINGS FOR:
A. CIRCUITING AND WIRING OF LIGHT FIXTURES AND SWITCHES
B. LIFE SAFETY EQUIPMENT AND EXIT SIGN LOCATIONS
C. LOCATION OF REQUIRED EMERGENCY LIGHT FIXTURES
D. LIGHT FIXTURE SPECIFICATIONS
21 COORDINATE WITH ALL TRADES INVOLVED AND COMPARE COMPOSITE SHOP DRAWINGS TO ENSURE CLEARANCES FOR LIGHT FIXTURES, DUCTWORK, CEILINGS, CABLING, ETC. NECESSARY TO MAINTAIN THE SPECIALIZED FINISH CEILING HEIGHT ABOVE THE FINISH FLOOR SLAB AS NOTED ON THE DRAWINGS.
CLARIFY CONFLICTS WITH ARCHITECTS IMMEDIATELY
22 ALL LIGHT FIXTURES TO BE CENTERED IN CEILING TILE, UNLESS OTHERWISE NOTED
23 WORK SHALL BE COMPLETED IN ACCORDANCE WITH ALL APPLICABLE BUILDING AND ENERGY CODES
24 COORDINATE WITH FINISH SCHEDULE FOR ALL CEILING FNISHES.
25 PROVIDE LEVEL 4 FINISH FOR ALL GYPSUM WALL BOARD CEILING & BULKHEADS UNLESS OTHERWISE
NOTED
26 PAINT ALL EXPOSED STRUCTURE & MECHANCIAL DUCTWORK IN AREAS SCHEDULED TO BE EXPOSED &
PAINTED. COORD. WITH FINISH SCHEDULE.
27 ANY CEILING HEIGHT CHANGES FROM THE CONTRACT DOCUMENTS MUST BE APPROVED BY THE OWNER
IN WRITING.
28 CONTRACTOR SHALL LAY CEILING TILE OUT SUCH THAT NO LESS THAN 12" OF TILE BE LEFT AT ANY END CONDITION. WHERE CEILING GRID SPECIFIED IS 24"X24", CONTRACTOR MAY UTILIZE 48" TILE CUT TO THE
REQUIRED DIMENSION (NO GREATER THAN 30") TO MEET THIS REQUIREMENT
29 ALL HORIZONTAL DUCTWORK RUNS FOR PLYMOVENT AND APPARATUS BAY EXHAUST SYSTEMS WITHIN THE APPARATUS BAY SHALL BE INSTALLED WITH THE BOTTOM OF THE DUCT AT A MIN. HEIGHT ABOVE FIN.
FLOOR OF 21'-0".
30 ALL EXPOSED CONDUIT RUNS WITHIN THE APPARATUS BAY SHALL BE INSTALLED TIGHT TO THE LONGSPAN STEEL TRUSS SYSTEMS WHEN RUNNING PARALLEL TO THE TRUSS SYSTEM. CONDUIT RUNS
PERPENDICULAR TO THE STRUCTURAL FRAMING SHALL OCCUR ALONG EITHER MASONRY WALL.
32 ALL PIPIING FOR SPRINKLER SYSTEM SHAL BE INSTALLED AT A MIN. HEIGHT ABOVE FIN. FLOOR OF 21'-0".
ISSUE # DATE DESCRIPTION
05/05/2025 DD 35% SUBMISSION
09/04/2025 DD 50% SUBMISSION
12/22/2025 CD 90% SUBMISSION
02/02/2026 BUILDING PERMIT
05/08/2026 CD100% / BID SUBMISSION
SCHEDULE - STATION ALERTING SYSTEM 1ST FLOOR
No. Abbrev. Description TAG MANUF. QTY NOTE OUTSIDE DOOR BELL DB Westnet 1
OUTSIDE HIGH POWER SPEAKER HPS Westnet 10
OUTSIDE SPEAKER OS Westnet 2
101 LOBBY A - XIT LIGHT A-XIT Westnet 1
101 LOBBY EMERGENCY BUTTON EB Westnet 1
102 WATCH SATTELITE CONTROLLER SC Westnet 1 1,2,9
104 TRAINING SATELLITE S Westnet 1 1,2,9
104 TRAINING SATTELITE CONTROLLER SC Westnet 1 1,2,9
104 TRAINING SPEAKER SWITCH SW Westnet 1
106 SUP. OFFICE VOLUME CONTROLER DVC Westnet 1
106 SUP. OFFICE SATTELITE CONTROLLER SC Westnet 1 1,2,9
106A SUP. BUNK DORM KNIGHT LIGHT DL Westnet 1 1,2,9
106A SUP. BUNK ROOM REMOTE NOTIFIER DR Westnet 1
107 SHIFT OFFICE VOLUME CONTROLER DVC Westnet 1
107 SHIFT OFFICE SATTELITE CONTROLLER SC Westnet 1 1,2,9
107A SHIFT BUNK DORM KNIGHT LIGHT DL Westnet 1 1,2,9
107A SHIFT BUNK ROOM REMOTE NOTIFIER DR Westnet 1
108 VOL. OFFICE VOLUME CONTROLER DVC Westnet 1
108 VOL. OFFICE SATTELITE CONTROLLER SC Westnet 1 1,2,9
110 DINING SATELLITE S Westnet 1 1,2,9
111 DAYROOM SATELLITE OSA Westnet 1
111 DAYROOM SATELLITE S Westnet 1 1,2,9
111 DAYROOM SATTELITE CONTROLLER SC Westnet 1 1,2,9
112 KITCHEN SATELLITE S Westnet 1 1,2,9
114 LAUNDRY SATTELITE CONTROLLER SC Westnet 1 1,2,9
115 BUNK DORM KNIGHT LIGHT DL Westnet 1 1,2,9
115 BUNK ROOM REMOTE NOTIFIER DR Westnet 1
116 BUNK DORM KNIGHT LIGHT DL Westnet 1 1,2,9
116 BUNK ROOM REMOTE NOTIFIER DR Westnet 1
117 BUNK DORM KNIGHT LIGHT DL Westnet 1 1,2,9
117 BUNK ROOM REMOTE NOTIFIER DR Westnet 1
118 WELL RM DORM KNIGHT LIGHT DL Westnet 1 1,2,9
118 WELL RM ROOM REMOTE NOTIFIER DR Westnet 1
118 WELL RM SATTELITE CONTROLLER SC Westnet 1 1,2,9
119 BUNK DORM KNIGHT LIGHT DL Westnet 1 1,2,9
119 BUNK ROOM REMOTE NOTIFIER DR Westnet 1
120 BUNK DORM KNIGHT LIGHT DL Westnet 1 1,2,9
120 BUNK ROOM REMOTE NOTIFIER DR Westnet 1
121 BUNK DORM KNIGHT LIGHT DL Westnet 1 1,2,9
121 BUNK ROOM REMOTE NOTIFIER DR Westnet 1
122 BUNK DORM KNIGHT LIGHT DL Westnet 1 1,2,9
122 BUNK ROOM REMOTE NOTIFIER DR Westnet 1
123 BUNK DORM KNIGHT LIGHT DL Westnet 1 1,2,9
123 BUNK ROOM REMOTE NOTIFIER DR Westnet 1
124 BUNK DORM KNIGHT LIGHT DL Westnet 1 1,2,9
124 BUNK ROOM REMOTE NOTIFIER DR Westnet 1
125 BUNK DORM KNIGHT LIGHT DL Westnet 1 1,2,9
125 BUNK ROOM REMOTE NOTIFIER DR Westnet 1
129 FITNESS ALERT STROBE ASLF Westnet 2
129 FITNESS VOLUME CONTROLER DVC Westnet 1
129 FITNESS EMERGENCY BUTTON EB Westnet 1
129 FITNESS SATELLITE OSA Westnet 1
129 FITNESS SATTELITE CONTROLLER SC Westnet 1 1,2,9
130 AIR LOCK SATTELITE CONTROLLER SC Westnet 1 1,2,9
132A AIR LOCK SATTELITE CONTROLLER SC Westnet 1 1,2,9
133 AIR LOCK SATTELITE CONTROLLER SC Westnet 1 1,2,9
134 LOCKERS SATELLITE S Westnet 2 1,2,9
134 LOCKERS SATTELITE CONTROLLER SC Westnet 1 1,2,9
135 APP BAY ALERTING DEVICE BRACKET BRK Westnet 2
135 APP BAY VOLUME CONTROLER DVC Westnet 2
135 APP BAY EXT. SPEAKER & BACK BOX OMNI Westnet 2 4
135 APP BAY MESSENGER TT Westnet 2
136 SHOP SATTELITE CONTROLLER SC Westnet 1 1,2,9
137 PPE GEAR SATELLITE S Westnet 2 1,2,9
137 PPE GEAR SATTELITE CONTROLLER SC Westnet 1 1,2,9
138 EXTRA PPE SATELLITE S Westnet 1 1,2,9
140 GEAR DRY SATTELITE CONTROLLER SC Westnet 1 1,2,9
141 DECON SATTELITE CONTROLLER SC Westnet 1 1,2,9
143 SCBA WORKRM SATTELITE CONTROLLER SC Westnet 1 1,2,9
151 BATH SATTELITE CONTROLLER SC Westnet 1 1,2,9
152 SHWR SATELLITE S Westnet 1 1,2,9
153 SHWR SATELLITE S Westnet 1 1,2,9
154 CH RM/TLT SATELLITE S Westnet 1 1,2,9
155 CH RM/TLT SATTELITE CONTROLLER SC Westnet 1 1,2,9
156 CH RM/TLT SATELLITE S Westnet 1 1,2,9
157 CH RM/TLT SATELLITE S Westnet 1 1,2,9
158 CH RM/TLT SATTELITE CONTROLLER SC Westnet 1 1,2,9
159 CH RM/TLT SATELLITE S Westnet 1 1,2,9
161 CORRIDOR VOLUME CONTROLER DVC Westnet 1
161 CORRIDOR KNIGHT LIGHT KL Westnet 3 <varies>
161 CORRIDOR SATELLITE S Westnet 1 1,2,9
161 CORRIDOR SATTELITE CONTROLLER SC Westnet 1 1,2,9
162 CORR KNIGHT LIGHT KL Westnet 2
162 CORR SATTELITE CONTROLLER SC Westnet 1 1,2,9
163 CORR KNIGHT LIGHT KL Westnet 8
163 CORR SATELLITE S Westnet 4 1,2,9
163 CORR SATTELITE CONTROLLER SC Westnet 1 1,2,9
209 SCBA STOR. SATELLITE S Westnet 1 1,2,9
209 SCBA STOR. SATTELITE CONTROLLER SC Westnet 1 1,2,9
212 MECH./ COMP. SATTELITE CONTROLLER SC Westnet 1 1,2,9
236 TRAINING SATELLITE S Westnet 1 1,2,9
236 TRAINING SATTELITE CONTROLLER SC Westnet 1 1,2,9
NOTES - LIGHTING
1 FIXTURES INDICATED AS BEING ON EMERGENCY CIRCUITS FOR EMERGENCY EGRESS SHALL BE ON SEGREGATED AUTOMATIC TRANSFER SYSTEM FROM THE STAND-BY POWER ATS TO MEET THE REQUIRED
RESTRIKE TIME FOR EGRESS LIGHTING. SEPARATE BATTERY PACKS ARE NOT REQUIRED.
2 VERIFY TYPE OF CEILING CONSTRUCTION FOR PROPER MOUNTING OF ALL RECESSED LIGHT FIXTURES.
INSTALLATION OF LIGHT FIXTURES SHALL COMPLY WITH ALL INTERNATIONAL BUILDING CODE
REQUIREMENTS.
3 ALL LIGHTING FIXTURES LOCATED SO AS TO DISRUPT A FIRE RATED CEILING ARE TO BE ENCLOSED OR SURROUNDED IN A FIRE PROTECTION MATERIAL AND FIBER BOARD. PROTECTION MATERIAL IS TO BE INSTALLED AS PER THE FIRE RESISTANCE INDEX. VERIFY WITH ARCHITECTURAL DRAWINGS THE HOUR
RATINGS AND TYPE OF CEILINGS TO BE USED.
4 RECESSED LIGHTING FIXTURES INSTALLED INTO METAL SUSPENDED CEILING SYSTEMS FOR LAY-IN TILES AND PANELS SHALL BE INSTALLED AND SUPPORTED IN ACCORDANCE WITH THE INTERNATIONAL BUILDING
CODE ASTM C635 AND C636
5 NOT USED
1 ACT CEILINGS: PROVIDE A SQUARE DEEP BOX WITH SINGLE GANG RING MOUNTED AT +10'-0" A.F.F. (TYPICAL) WITH 1" SLEEVE INTO 4 SQUARE DEEP BOX. KEEP CLEAR OF OBSTRUCTION. (TYPICAL)" SLEEVE INTO 4
SQUARE DEEP BOX.
2 GWB CEILINGS: PROVIDE 8X10X4 HOFFMAN BACK BOX MOUNTED IN SHEETROCK CEILINGS RECESSED 1/4"
BEHIND SHEETROCK FACE 3/4" CONDUIT. KEEP CLEAR OF OBSTRUCTIONS. (TYPICAL)
3 DORM LIGHTS: A CUSTOM BACK BOX SHAL BE PROVIDED BY WESTNET. MOUNT BOX IN CENTER OF ROOM AT
FOOT OF BED. LOCATION WITH CONDUIT TO DORM REMOTE. KEEP CLEAR OF CEILING FANS OR
OBSTRUCTIONS .(TYPICAL)
4 DORM REMOTE: PROVIDE 8X10X4 HOFFMAN BACK BOX MOUNTED HORIZONTALLY AT +48" A.F.F. WITH 3/4" CONDUIT STUB UP ABOVE CEILING TO NEXT DEVICE. KEEP CLEAR OF OBSTRUCTION. (TYPICAL)
5 PROVIDE A 4 SQUARE DEEP BOX WITH SINGLE GANG RING MOUNTED AT +9'-0" A.F.F. WITH 3/4" CONDUIT TO CABINET. KEEP CLEAR OF OBSTRUCTIONS (TYPICAL). COORDINATE WITH ARCH. ENLARGED PLANS &
INTERIOR ELEVATIONS FOR MOUNTING HEIGHTS AND LOCATIONS.
6 PROVIDE UNISTRUT MOUNTING BRACKET WHERE INDICATED FOR OFFSET MOUNTING OF DEVICES.
7 PROVIDE A 4 SQUARE DEEP SINGLE GANG RING BOX MOUNTED AT +48" A.F.F. 3/4" CONDUIT SLEEVE TO ACCESSIBLE CEILING. COORDINATE WITH ARCH. ENLARGED PLANS & INTERIOR ELEVATIONS FOR MOUNTING
HEIGHTS AND LOCATIONS.
8 INSTALL CUSTOM BACK BOX FROM WESTNET MOUNTED VERTICALLY (COORD. HEIGHT W/ ELEV.). TO BOTTOM WITH 3/4" CONDUIT TO ACCESSIBLE CEILING SPACE. (TYPICAL) KEEP CLEAR OF OBSTRUCTIONS
9 OPEN CEILINGS: MOUNT DEVICE TO UNDERSIDE OF JOISTS.
10 APPLIANCE CONTROLLER DEVICE TO BE MOUNTED IN ACCESSIBLE AREA NEXT TO THE GAS SOLENOID. A DEDICATED 120V CIRCUIT IS TO BE PROVIDED FOR THE ACD. THE APPLIANCE CONTROLLER CONTROLS TWO OUTPUTS: GAS AND STOVE'S AC POWER. THE RELAY FOR THE AC POWER SHOULD HAVE A COIL CONTROL VOLTAGE RATING OF 24 V AC. OVEN/ RANGES & BBQ MUST USE A SEPARATE GAS VALVE. A RELAY PROVIDED BY THE ELECTRICAL SUBCONTRACTOR SHALL BE USED TO CONTROL 120V POWER FOR THE OVEN/ RANGE APPLIANCE. STOVES WITH ELECTRONIC IGNITION EQUIPMENT WILL REQUIRE DISCONNECTION OF THE
ELECTRICAL POWER DURING ALERTS.
masif Line masif Line masif Text Box Mark A. Manetti masif Text Box License Number masif Text Box Date masif Text Box 0401010972 masif Line masif Snapshot masif Snapshot masif
FACE
FACE
FACE
F A
C E
D
F A
C E
F
F A
C E
E
F A
C E
G
FACE
FACE
A850
A850
KITCHEN
BUNK
BUNK
BUNK
117 LAUNDRY
ROOM/
JANITOR
PANTRY
112A
PANTRY
112B
PANTRY
112C
PANTRY
112D
CORRIDOR
CORRIDOR
STORAGE
CLOSET
DECON
VEST B
BUNK
BUNK
BUNK
BUNK
BUNK
BUNK
BUNK
PHYSICAL
CONDITIONING
ROOM
ACC. APP
BAY
SHOWER
APP BAY
SHOWER
MEDICAL
STORAGE
DECON
VEST A
COMMUNICATIONS
ROOM
WELLNESS
ROOM
LOCKERS
ACC.
CHANGING
ROOM &
TOILET
ACC.
CHANGING
ROOM &
TOILET
CHANGING
ROOM &
TOILET
CHANGING
ROOM &
TOILET
CHANGING
ROOM &
TOILET
FIRE PUMP
ROOM
CUBBIES
132A
MECHANICAL
CLOSET
3.1 4.1 4.9
F A
C E
G.1
F A
C E
G.2
FACE
4.8
D.2
F A
C E
D.3
F A
C E
D.4
F A
C E
D.8
A710
9' - 0"
ACT-1
9' - 0"
ACT-1
9' - 0"
GYP-1
9' - 0"
GYP-1
9' - 0"
GYP-1 11' - 0"
GYP-1
9' - 0"
GYP-1
9' - 0"
ACT-1
9' - 0"
GYP-1
9' - 0"
GYP-1
9' - 0"
GYP-1
9' - 0"
GYP-1
9' - 0"
GYP-1
9' - 0"
GYP-1
9' - 0"
GYP-1
9' - 0"
GYP-1
9' - 0"
ACT-1
9' - 0"
ACT-1 9' - 0"
ACT-1
9' - 0"
ACT-1
9' - 0"
ACT-1
9' - 0"
ACT-1 9' - 0"
ACT-1
9' - 0"
ACT-1
9' - 0"
ACT-1
9' - 0"
GYP-1
9' - 0"
GYP-1
9' - 0"
GYP-1
9' - 0"
GYP-1
9' - 0"
GYP-1
9' - 0"
GYP-1
9' - 0"
GYP-1
9' - 0"
GYP-1
9' - 0"
GYP-1
PT-1
PT-1PT-1PT-1
PT-1
PT-1
PT-1 PT-1
PT-1PT-1
PT-1 PT-1 PT-1 PT-1 PT-1
PT-1
PT-1
PT-1
PT-1
PT-1
PT-1
PT-1
EXPOSED CEILING
PAINTED PT-1
SC
S
SS
S
S
S S
S
S
S
S
SC
SC
SC
SCS S
SC
SC
SC
SC
SC
DLDLDL
DL
DL
DL
DL DL DL DL DL
KLKLKL
KL
KL
KL
KL KL
KL
KL
ACC.
CHANGING
ROOM &
TOILET
SC
3' - 6"
1' - 8 5/8"
23' - 1"
CL
EXPOSED CEILING
PAINTED PT-4
EXPOSED CEILING
PAINTED PT-4
FIRE STATION ALERTING SCOPE
1. STAFFORD COUNTY FIRE STATIONS USE A PROPRIETARY ALERT NOTIFICATION SYSTEM: “WESTNET FIRST
IN”. THE STATION ALERTING SYSTEM WILL BE A TURNKEY DELIVERY THROUGH THE GENERAL
CONTRACTOR. THE GENERAL CONTRACTOR IS TO CONTRACT DIRECTLY WITH WESTNET FOR THIS
TURNKEY DELIVERY, AND INCLUDE PRICING FOR THE FULL DELIVERY OF THE STATION ALERTING SYSTEM IN THEIR BID. THE GENERAL CONTRACTOR IS TO PROVIDE ALL INFRASTRUCTURE REQUIRED TO FACILITATE A FULLY FUNCTIONING STATION ALERTING SYSTEM PER THE WESTNET DRAWINGS INCLUDED
WITH DEVICES TO SUPPORT STATION ALERTING SYSTEM.
A. PROVIDE COMMUNICATIONS RACK REQUIRED TO SUPPORT STATION ALERTING SYSTEM.
2. SCOPE OF WORK UNDER STATION ALERTING TURNKEY DELIVERY:
A. PROVIDE ALL DEVICES INCLUDED ON WESTNET DRAWINGS INCLUDED WITH SPECIFICATIONS AND
REFERENCED ON ARCHITECTURAL AND ELECTRICAL DRAWINGS.
B. PROVIDE UPS REQUIRED FOR POWERING STATION ALERTING SYSTEM.
C. PROVIDE ALL CABLES REQUIRED FOR STATION ALERTING SYSTEM.
D. PROVIDE ALL HOFFMAN BOX REQUIRED FOR STATION ALERTING SYSTEM.
E. PROVIDE ALL INFRASTRUCTURE TO SUPPORT THE WESTNET STATION ALERTING SYSTEM.
INFRASTRUCTURE REQUIREMENTS ARE IDENTIFIED ON THE ELECTRICAL DRAWINGS. THE GENERAL
CONTRACTOR’S ELECTRICAL SUBCONTRACTOR SHALL REVIEW THE WESTNET DRAWINGS INCLUDED
WITH SPECIFICATIONS AND THE ELECTRICAL AND ARCHITECTURAL CONTRACT DRAWINGS.
F. ARCHITECTURAL REFLECTED CEILING PLANS AND INTERIOR ELEVATIONS INDICATE ACTUAL WESTNET
DEVICE LOCATIONS FOR COORDINATION WITH FINISHES AND OTHER BUILDING SYSTEMS.
G. DEVICES LOCATED IN ACOUSTICAL CEILINGS DO NOT REQUIRE BACKBOX.
H. DEVICES LOCATED IN SHEETROCK OR EXPOSED CEILINGS REQUIRE BACKBOXES.
I. FINAL LOCATIONS OF DEVICES SHALL BE DETERMINED AT THE TIME OF INSTALLATION BY THE
CERTIFIED INSTALLER IN CONSULTATION WITH THE STAFFORD COUNTY FIRE & RESCUE DEPARTMENT.
J. COORDINATE WITH SPECIFICATIONS FOR ADDITIONAL ROUGH-IN AND INSTALLATION DETAILS AND
INFORMATION.
K. GC’S ELECTRICAL SUB-CONTRACTOR SHALL VERIFY WALL AND CEILING TYPES AND COORDINATE WITH
WESTNET TO DETERMINE NEED FOR FLUSH OR SURFACE MOUNT INSTALLATION OF EQUIPMENT
SPECIFIED PRIOR TO INSTALLING REQUIRED INFRASTRUCTURE.
L. SATELLITE & SATELLITE CONTROLLER MUST BE VISIBLE FROM SHOWER. GC’S ELECTRICAL SUB-
CONTRACTOR SHALL VERIFY LOCATION IN FIELD PRIOR TO INSTALLING INFRASTRUCTURE.
M. DORM LIGHTS, SATELLIGHT, & OR SATELLIGHT CONTROLLERS NEAR CEILING FANS MUST BE KEPT
CLEAR OF OBSTRUCTIONS & CEILING FANS DUE TO PHOTOSENSITIVE EPILEPSY.
N. PROVIDE 3/4" CONDUIT FOR ALL SYSTEM WIRING UNLESS OTHERWISE NOTED. CONDUIT SHALL BE CONCEALED ON PARTITIONS OR ABOVE THE CEILING. ALL WIRING AND DEVICES TO BE INSTALLED BY
WESTNET CERTIFIED INSTALLER.
O. ALL BACK BOXES ARE TO BE INSTALLED BY THE GENERAL CONTRACTOR’S ELECTRICAL SUB-
CONTRACTOR AND COORDINATED WITH WESTNET FOR COMPATIBILITY WITH WESTNET DEVICES.
P. THE GENERAL CONTRACTOR SHALL ADVISE THE ARCHITECT OF ANY PERCEIVED DISCREPANCIES
BETWEEN THE WESTNET DRAWINGS AND THE ARCHITECTURAL AND ELECTRICAL DRAWINGS FOR
CLARIFICATION AND DIRECTION.
GENERAL NOTES - WESTNET STATION ALERTING SYSTEM
2' X 2' LIGHT FIXTURE. COORD. W/
LIGHTING FIXT. SCHED.
SUSPENDED STEM MTD. FIXTURES.
COORD. W/ LIGHTING FIXT. SCHED.
RECCESED CAN DOWNLIGHT.
COORD. W/ LIGHTING FIXT. SCHED.
LEGEND - RCP
SUSPENDED HI-BAY STEM MTD.
FIXTURES. COORD. W/ LIGHTING FIXT.
SCHED.
CEILING FAN LOCATION. COORD. W/
EQUIPMENT SCHEDULE
RETURN AIR GRILLE. COORD. W/
MECH. DWGS.
SUPPLY AIR DIFFUSER. COORD. W/
MECH. DWGS.
EQ EQ
E Q
E Q
FANS SPEAKER SYSTEM
FANS COLOR INDICATOR
FINISH CLG. HEIGHT
CEILING ASSEMBLY
2' X 2' LIGHT FIXTURE - EMER.
POWER. COORD. W/ LIGHTING FIXT.
SCHED.
SPEAKER
EQ EQ
E Q
E Q
WALL SCONCE. COORD. W/ LIGHTING
FIXT. SCHED.
DOME PENDANT. COORD. W/
LIGHTING FIXT. SCHED.
CEILING ACCESS PANEL -
CONTRACTOR TO CONFIRM ALL
QUANTITIES AND LOCATIONS
SOLID GRAY WALLS INDICATE
PARTITIONS THAT EXTEND UP TO
ROOF OR FLOOR STRUCTURE ABOVE
LEGEND - WESTNET DEVICES
SATELLIGHT
SATELLIGHT CONTROLLER
S
SC
TT TURNOUT TIMER - MEDIUM
HPS
HPA
HIGH-POWERED SPEAKER
HIGH-POWERED AMPLIFIER
ASLF
ALERT STROBE LIGHT
FIXTURE
SP SPEAKER
DL DORM LIGHT
A-XIT
KL
ACTIVE X-IT LIGHT STRIP
KNIGHT LIGHT
OMNI
OMNI DIRECTIONAL
SPEAKER
DORM REMOTE
DIGITAL VOLUME CONTROL
DR
DVC
SW
OUTSIDE SPEAKER AUDIO
MODULE SINGLE
DB
OSA
EB EMERGENCY BUTTON
SPEAKER SWITCH
DOOR BELL
Architecture Interior Design Landscape Architecture Engineering
TRUE NORTH PLAN NORTH
1054 31st Street NW Canal Square Suite 410 Washington, DC 20007 202.595.3173 www.bkvgroup.com
© 2021 BKV Group
SHEET NUMBER
SHEET TITLE
DRAWN BY
CHECKED BY
COMMISSION NUMBER
PROJECT TITLE
CONSULTANTS
CERTIFICATION
KEYPLAN
A u to d e s k D o c s /2
.0
S ta ff o rd
F ir e -R e s c u e
S ta ti o n -8
/2
-0
F
R -8
A
I_
.r v t
/8
/2
:0
:2
P
M
B.Adams
M.Manetti
2540.03
A301B
REFLECTED
CEILING PLAN -
LEVEL 1 AREA B
STAFFORD
COUNTY FIRE &
RESCUE
STATION 8 -
ROCK HILL
A301B 1/4" = 1'-0"
1 LEVEL 1 - AREA B - REFLECTED CEILING PLAN
B
A
C D
GENERAL RCP NOTES
1 DO NOT SCALE DRAWINGS
2 LOCATION OF DEVICES AND EQUIPMENT SHOWN ON DRAWINGS OF OTHER DISCIPLINES ARE SCHEMATIC AND GENERAL. SPECIFIC LOCATIONS OR GUIDELINES INDICATED ON ARCHITECTURAL DRAWINGS SHALL
GOVERN THE LOCATION OF EXPOSED WORK OF ALL TRADES
3 INSTALL SPRINKLER HEADS, SMOKE ALARMS, LIGHT FIXTURES OR OTHER EXPOSED DEVICES AT CENTER OF ACOUSTICAL TILE (WHERE OCCURS), AT CENTER OF SOFFIT (WHERE OCCURS), OR AT CENTER OF ROOM, UNO. IF DIMENSION TO LOCATE A SPECIFIC DEVICE IS GIVEN IN ONE DIRECTION, CONTRACTOR TO
CENTER THE DEVICE ON CEILING OR SOFFIT IN THE OTHER DIRECTION
4 FOR CLARITY, UNDER-CABINET, TASK, AND COVE LIGHTING ARE NOT SHOWN ON THE ARCHITECTURAL RCP. SEE A8 SERIES (INTERIOR ELEVATIONS) AND A9 SERIES (INTERIORS DETAILS) FOR LOCATIONS
5 REMOVE ALL BARCODE, TAGS, ETC. FROM CONDUIT, PIPING AND DUCTWORK PRIOR TO INSTALLATION.
ROTATE PERMANENT MARKINGS TO CONCEAL.
6 CEILING HEIGHTS ARE SHOWN ON THE REFLECTED CEILING PLAN. ALL CEILING HEIGHTS INDICATED ARE
FROM FLOOR ELEVATION IMMEDIATELY BELOW.
7 AT EXPOSED CEILING CONDITIONS, COORDINATE ALL WIRING, CONDUIT, DUCTS, ETC. FOR AN ORGANIZED
FINISHED LOOK
8 REFER TO ELECTRICAL DRAWINGS AND FIRE PROTECTION DRAWING FOR FIXTURE EQUIPMENT TYPE
9 REFER TO MECHANICAL, PLUMBING, ELECTRICAL, AND FIRE PROTECTION DRAWINGS FOR ADDITIONAL
INFORMATION
10 PLACE ALL CEILING MOUNTED EQUIPMENT IN THE CENTER OF THE CEILING TILE UNLESS OTHERWISE
NOTED. COORDINATE ALL DISCREPANCIES WITH ARCHITECT PRIOR TO INSTALLATION
11 SEE INTERIOR ELEVATIONS / SECTIONS / DETAILS FOR ADDITIONAL INFORMATION ON FINISHED SOFFIT, BULKHEAD, CEILING, ETC. WHERE NOT INDICATED ON REFLECTED CEILING PLAN
12 REFER TO ADDITIONAL NOTES AND REQUIREMENTS ON ALL OTHER DOCUMENTS AND OTHER DISCIPLINES
DOCUMENTS
13 PAINT ALL STRUCTURE EXPOSED TO VIEW UNLESS NOTED OTHERWISE. PAINT ALL EXPOSED CONDUIT
PIPE, DUCTWORK, ETC.
14 PAINT ALL GYPSUM BOARD CEILINGS, SEE FINISH SCHEDULE FOR PAINT COLOR
15 CENTER ALL FIXTURES AND DEVICES IN CEILING TILE, UNLESS OTHERWISE NOTED
16 ALL EXIT DEVICES TO BE PENDANT MOUNTED FROM DECK EXCEPT MAIN ENTRY, EXIT SIGN WHICH IS TO BE
WALL MOUNTED AND CENTERED ABOVE DOORS
17 COORDINATE LOCATION OF ALL LIGHT SWITCHES AND THERMOSTATS W/ ARCHITECT AND OWNER PRIOR TO CONSTRUCTION. PROVIDE SHOP DRAWING INDICATING ALL DEVICE LOCATIONS AND PROPOSED
HEIGHTS FOR REVIEW AND APPROVAL.
18 INSTALL MECHANICAL AND PLUMBING WORK TIGHT TO STRUCTURAL ELEMENTS TO MAINTAIN MAXIMUM
CEILING HEIGHT UNLESS NOTED OTHERWIOSE ON DRAWINGS
19 MECHANICAL SHOWN FOR REFERENCE ONLY, REFER TO THE MECHANICAL DRAWINGS FOR:
A. DUCTWORK, AIR MOVEMENT REQUIREMENTS; SIZES OF GRILLES, DIFFUSERS AND REGISTERS
20 LIGHT FIXTURES SHOWN FOR REFERENCE ONLY. REFER TO THE ELECTRICAL DRAWINGS FOR:
A. CIRCUITING AND WIRING OF LIGHT FIXTURES AND SWITCHES
B. LIFE SAFETY EQUIPMENT AND EXIT SIGN LOCATIONS
C. LOCATION OF REQUIRED EMERGENCY LIGHT FIXTURES
D. LIGHT FIXTURE SPECIFICATIONS
21 COORDINATE WITH ALL TRADES INVOLVED AND COMPARE COMPOSITE SHOP DRAWINGS TO ENSURE CLEARANCES FOR LIGHT FIXTURES, DUCTWORK, CEILINGS, CABLING, ETC. NECESSARY TO MAINTAIN THE SPECIALIZED FINISH CEILING HEIGHT ABOVE THE FINISH FLOOR SLAB AS NOTED ON THE DRAWINGS.
CLARIFY CONFLICTS WITH ARCHITECTS IMMEDIATELY
22 ALL LIGHT FIXTURES TO BE CENTERED IN CEILING TILE, UNLESS OTHERWISE NOTED
23 WORK SHALL BE COMPLETED IN ACCORDANCE WITH ALL APPLICABLE BUILDING AND ENERGY CODES
24 COORDINATE WITH FINISH SCHEDULE FOR ALL CEILING FNISHES.
25 PROVIDE LEVEL 4 FINISH FOR ALL GYPSUM WALL BOARD CEILING & BULKHEADS UNLESS OTHERWISE
NOTED
26 PAINT ALL EXPOSED STRUCTURE & MECHANCIAL DUCTWORK IN AREAS SCHEDULED TO BE EXPOSED &
PAINTED. COORD. WITH FINISH SCHEDULE.
27 ANY CEILING HEIGHT CHANGES FROM THE CONTRACT DOCUMENTS MUST BE APPROVED BY THE OWNER
IN WRITING.
28 CONTRACTOR SHALL LAY CEILING TILE OUT SUCH THAT NO LESS THAN 12" OF TILE BE LEFT AT ANY END CONDITION. WHERE CEILING GRID SPECIFIED IS 24"X24", CONTRACTOR MAY UTILIZE 48" TILE CUT TO THE
REQUIRED DIMENSION (NO GREATER THAN 30") TO MEET THIS REQUIREMENT
29 ALL HORIZONTAL DUCTWORK RUNS FOR PLYMOVENT AND APPARATUS BAY EXHAUST SYSTEMS WITHIN THE APPARATUS BAY SHALL BE INSTALLED WITH THE BOTTOM OF THE DUCT AT A MIN. HEIGHT ABOVE FIN.
FLOOR OF 21'-0".
30 ALL EXPOSED CONDUIT RUNS WITHIN THE APPARATUS BAY SHALL BE INSTALLED TIGHT TO THE LONGSPAN STEEL TRUSS SYSTEMS WHEN RUNNING PARALLEL TO THE TRUSS SYSTEM. CONDUIT RUNS
PERPENDICULAR TO THE STRUCTURAL FRAMING SHALL OCCUR ALONG EITHER MASONRY WALL.
32 ALL PIPIING FOR SPRINKLER SYSTEM SHAL BE INSTALLED AT A MIN. HEIGHT ABOVE FIN. FLOOR OF 21'-0".
ISSUE # DATE DESCRIPTION
05/05/2025 DD 35% SUBMISSION
09/04/2025 DD 50% SUBMISSION
12/22/2025 CD 90% SUBMISSION
02/02/2026 BUILDING PERMIT
05/08/2026 CD100% / BID SUBMISSION
SCHEDULE - STATION ALERTING SYSTEM 1ST FLOOR
No. Abbrev. Description TAG MANUF. QTY NOTE OUTSIDE DOOR BELL DB Westnet 1
OUTSIDE HIGH POWER SPEAKER HPS Westnet 10
OUTSIDE SPEAKER OS Westnet 2
101 LOBBY A - XIT LIGHT A-XIT Westnet 1
101 LOBBY EMERGENCY BUTTON EB Westnet 1
102 WATCH SATTELITE CONTROLLER SC Westnet 1 1,2,9
104 TRAINING SATELLITE S Westnet 1 1,2,9
104 TRAINING SATTELITE CONTROLLER SC Westnet 1 1,2,9
104 TRAINING SPEAKER SWITCH SW Westnet 1
106 SUP. OFFICE VOLUME CONTROLER DVC Westnet 1
106 SUP. OFFICE SATTELITE CONTROLLER SC Westnet 1 1,2,9
106A SUP. BUNK DORM KNIGHT LIGHT DL Westnet 1 1,2,9
106A SUP. BUNK ROOM REMOTE NOTIFIER DR Westnet 1
107 SHIFT OFFICE VOLUME CONTROLER DVC Westnet 1
107 SHIFT OFFICE SATTELITE CONTROLLER SC Westnet 1 1,2,9
107A SHIFT BUNK DORM KNIGHT LIGHT DL Westnet 1 1,2,9
107A SHIFT BUNK ROOM REMOTE NOTIFIER DR Westnet 1
108 VOL. OFFICE VOLUME CONTROLER DVC Westnet 1
108 VOL. OFFICE SATTELITE CONTROLLER SC Westnet 1 1,2,9
110 DINING SATELLITE S Westnet 1 1,2,9
111 DAYROOM SATELLITE OSA Westnet 1
111 DAYROOM SATELLITE S Westnet 1 1,2,9
111 DAYROOM SATTELITE CONTROLLER SC Westnet 1 1,2,9
112 KITCHEN SATELLITE S Westnet 1 1,2,9
114 LAUNDRY SATTELITE CONTROLLER SC Westnet 1 1,2,9
115 BUNK DORM KNIGHT LIGHT DL Westnet 1 1,2,9
115 BUNK ROOM REMOTE NOTIFIER DR Westnet 1
116 BUNK DORM KNIGHT LIGHT DL Westnet 1 1,2,9
116 BUNK ROOM REMOTE NOTIFIER DR Westnet 1
117 BUNK DORM KNIGHT LIGHT DL Westnet 1 1,2,9
117 BUNK ROOM REMOTE NOTIFIER DR Westnet 1
118 WELL RM DORM KNIGHT LIGHT DL Westnet 1 1,2,9
118 WELL RM ROOM REMOTE NOTIFIER DR Westnet 1
118 WELL RM SATTELITE CONTROLLER SC Westnet 1 1,2,9
119 BUNK DORM KNIGHT LIGHT DL Westnet 1 1,2,9
119 BUNK ROOM REMOTE NOTIFIER DR Westnet 1
120 BUNK DORM KNIGHT LIGHT DL Westnet 1 1,2,9
120 BUNK ROOM REMOTE NOTIFIER DR Westnet 1
121 BUNK DORM KNIGHT LIGHT DL Westnet 1 1,2,9
121 BUNK ROOM REMOTE NOTIFIER DR Westnet 1
122 BUNK DORM KNIGHT LIGHT DL Westnet 1 1,2,9
122 BUNK ROOM REMOTE NOTIFIER DR Westnet 1
123 BUNK DORM KNIGHT LIGHT DL Westnet 1 1,2,9
123 BUNK ROOM REMOTE NOTIFIER DR Westnet 1
124 BUNK DORM KNIGHT LIGHT DL Westnet 1 1,2,9
124 BUNK ROOM REMOTE NOTIFIER DR Westnet 1
125 BUNK DORM KNIGHT LIGHT DL Westnet 1 1,2,9
125 BUNK ROOM REMOTE NOTIFIER DR Westnet 1
129 FITNESS ALERT STROBE ASLF Westnet 2
129 FITNESS VOLUME CONTROLER DVC Westnet 1
129 FITNESS EMERGENCY BUTTON EB Westnet 1
129 FITNESS SATELLITE OSA Westnet 1
129 FITNESS SATTELITE CONTROLLER SC Westnet 1 1,2,9
130 AIR LOCK SATTELITE CONTROLLER SC Westnet 1 1,2,9
132A AIR LOCK SATTELITE CONTROLLER SC Westnet 1 1,2,9
133 AIR LOCK SATTELITE CONTROLLER SC Westnet 1 1,2,9
134 LOCKERS SATELLITE S Westnet 2 1,2,9
134 LOCKERS SATTELITE CONTROLLER SC Westnet 1 1,2,9
135 APP BAY ALERTING DEVICE BRACKET BRK Westnet 2
135 APP BAY VOLUME CONTROLER DVC Westnet 2
135 APP BAY EXT. SPEAKER & BACK BOX OMNI Westnet 2 4
135 APP BAY MESSENGER TT Westnet 2
136 SHOP SATTELITE CONTROLLER SC Westnet 1 1,2,9
137 PPE GEAR SATELLITE S Westnet 2 1,2,9
137 PPE GEAR SATTELITE CONTROLLER SC Westnet 1 1,2,9
138 EXTRA PPE SATELLITE S Westnet 1 1,2,9
140 GEAR DRY SATTELITE CONTROLLER SC Westnet 1 1,2,9
141 DECON SATTELITE CONTROLLER SC Westnet 1 1,2,9
143 SCBA WORKRM SATTELITE CONTROLLER SC Westnet 1 1,2,9
151 BATH SATTELITE CONTROLLER SC Westnet 1 1,2,9
152 SHWR SATELLITE S Westnet 1 1,2,9
153 SHWR SATELLITE S Westnet 1 1,2,9
154 CH RM/TLT SATELLITE S Westnet 1 1,2,9
155 CH RM/TLT SATTELITE CONTROLLER SC Westnet 1 1,2,9
156 CH RM/TLT SATELLITE S Westnet 1 1,2,9
157 CH RM/TLT SATELLITE S Westnet 1 1,2,9
158 CH RM/TLT SATTELITE CONTROLLER SC Westnet 1 1,2,9
159 CH RM/TLT SATELLITE S Westnet 1 1,2,9
161 CORRIDOR VOLUME CONTROLER DVC Westnet 1
161 CORRIDOR KNIGHT LIGHT KL Westnet 3 <varies>
161 CORRIDOR SATELLITE S Westnet 1 1,2,9
161 CORRIDOR SATTELITE CONTROLLER SC Westnet 1 1,2,9
162 CORR KNIGHT LIGHT KL Westnet 2
162 CORR SATTELITE CONTROLLER SC Westnet 1 1,2,9
163 CORR KNIGHT LIGHT KL Westnet 8
163 CORR SATELLITE S Westnet 4 1,2,9
163 CORR SATTELITE CONTROLLER SC Westnet 1 1,2,9
209 SCBA STOR. SATELLITE S Westnet 1 1,2,9
209 SCBA STOR. SATTELITE CONTROLLER SC Westnet 1 1,2,9
212 MECH./ COMP. SATTELITE CONTROLLER SC Westnet 1 1,2,9
236 TRAINING SATELLITE S Westnet 1 1,2,9
236 TRAINING SATTELITE CONTROLLER SC Westnet 1 1,2,9
NOTES - LIGHTING
1 FIXTURES INDICATED AS BEING ON EMERGENCY CIRCUITS FOR EMERGENCY EGRESS SHALL BE ON SEGREGATED AUTOMATIC TRANSFER SYSTEM FROM THE STAND-BY POWER ATS TO MEET THE REQUIRED
RESTRIKE TIME FOR EGRESS LIGHTING. SEPARATE BATTERY PACKS ARE NOT REQUIRED.
2 VERIFY TYPE OF CEILING CONSTRUCTION FOR PROPER MOUNTING OF ALL RECESSED LIGHT FIXTURES.
INSTALLATION OF LIGHT FIXTURES SHALL COMPLY WITH ALL INTERNATIONAL BUILDING CODE
REQUIREMENTS.
3 ALL LIGHTING FIXTURES LOCATED SO AS TO DISRUPT A FIRE RATED CEILING ARE TO BE ENCLOSED OR SURROUNDED IN A FIRE PROTECTION MATERIAL AND FIBER BOARD. PROTECTION MATERIAL IS TO BE INSTALLED AS PER THE FIRE RESISTANCE INDEX. VERIFY WITH ARCHITECTURAL DRAWINGS THE HOUR
RATINGS AND TYPE OF CEILINGS TO BE USED.
4 RECESSED LIGHTING FIXTURES INSTALLED INTO METAL SUSPENDED CEILING SYSTEMS FOR LAY-IN TILES AND PANELS SHALL BE INSTALLED AND SUPPORTED IN ACCORDANCE WITH THE INTERNATIONAL BUILDING
CODE ASTM C635 AND C636
5 NOT USED
1 ACT CEILINGS: PROVIDE A SQUARE DEEP BOX WITH SINGLE GANG RING MOUNTED AT +10'-0" A.F.F. (TYPICAL) WITH 1" SLEEVE INTO 4 SQUARE DEEP BOX. KEEP CLEAR OF OBSTRUCTION. (TYPICAL)" SLEEVE INTO 4
SQUARE DEEP BOX.
2 GWB CEILINGS: PROVIDE 8X10X4 HOFFMAN BACK BOX MOUNTED IN SHEETROCK CEILINGS RECESSED 1/4"
BEHIND SHEETROCK FACE 3/4" CONDUIT. KEEP CLEAR OF OBSTRUCTIONS. (TYPICAL)
3 DORM LIGHTS: A CUSTOM BACK BOX SHAL BE PROVIDED BY WESTNET. MOUNT BOX IN CENTER OF ROOM AT
FOOT OF BED. LOCATION WITH CONDUIT TO DORM REMOTE. KEEP CLEAR OF CEILING FANS OR
OBSTRUCTIONS .(TYPICAL)
4 DORM REMOTE: PROVIDE 8X10X4 HOFFMAN BACK BOX MOUNTED HORIZONTALLY AT +48" A.F.F. WITH 3/4" CONDUIT STUB UP ABOVE CEILING TO NEXT DEVICE. KEEP CLEAR OF OBSTRUCTION. (TYPICAL)
5 PROVIDE A 4 SQUARE DEEP BOX WITH SINGLE GANG RING MOUNTED AT +9'-0" A.F.F. WITH 3/4" CONDUIT TO CABINET. KEEP CLEAR OF OBSTRUCTIONS (TYPICAL). COORDINATE WITH ARCH. ENLARGED PLANS &
INTERIOR ELEVATIONS FOR MOUNTING HEIGHTS AND LOCATIONS.
6 PROVIDE UNISTRUT MOUNTING BRACKET WHERE INDICATED FOR OFFSET MOUNTING OF DEVICES.
7 PROVIDE A 4 SQUARE DEEP SINGLE GANG RING BOX MOUNTED AT +48" A.F.F. 3/4" CONDUIT SLEEVE TO ACCESSIBLE CEILING. COORDINATE WITH ARCH. ENLARGED PLANS & INTERIOR ELEVATIONS FOR MOUNTING
HEIGHTS AND LOCATIONS.
8 INSTALL CUSTOM BACK BOX FROM WESTNET MOUNTED VERTICALLY (COORD. HEIGHT W/ ELEV.). TO BOTTOM WITH 3/4" CONDUIT TO ACCESSIBLE CEILING SPACE. (TYPICAL) KEEP CLEAR OF OBSTRUCTIONS
9 OPEN CEILINGS: MOUNT DEVICE TO UNDERSIDE OF JOISTS.
10 APPLIANCE CONTROLLER DEVICE TO BE MOUNTED IN ACCESSIBLE AREA NEXT TO THE GAS SOLENOID. A DEDICATED 120V CIRCUIT IS TO BE PROVIDED FOR THE ACD. THE APPLIANCE CONTROLLER CONTROLS TWO OUTPUTS: GAS AND STOVE'S AC POWER. THE RELAY FOR THE AC POWER SHOULD HAVE A COIL CONTROL VOLTAGE RATING OF 24 V AC. OVEN/ RANGES & BBQ MUST USE A SEPARATE GAS VALVE. A RELAY PROVIDED BY THE ELECTRICAL SUBCONTRACTOR SHALL BE USED TO CONTROL 120V POWER FOR THE OVEN/ RANGE APPLIANCE. STOVES WITH ELECTRONIC IGNITION EQUIPMENT WILL REQUIRE DISCONNECTION OF THE
ELECTRICAL POWER DURING ALERTS.
masif Line masif Line masif Text Box Mark A. Manetti masif Text Box License Number masif Text Box Date masif Text Box 0401010972 masif Line masif Snapshot masif Snapshot masif
FACE
F A
C E
C
F A
C E
D
F A
C E
B
F A
C E
E
APPARATUS
BAY
B.9
D.2
F A
C E
D.3
F A
C E
D.4
F A
C E
D.8
F A
C E
B.1
F1F1F1F1
EXPOSED CEILING
PAINTED PT-4
F1
FN1FN1
FN1
FN1
F1 F1 F1
AFU-07 AFU-09 AFU-10
AFU-05AFU-04AFU-03AFU-02AFU-01
AFU-06 AFU-07 AFU-08
EF-2
EUH-5
EUH-4
EUH-7EUH-6
HB HB HBHBHB
HB HB HB HB HB
HBHBHB
HBHBHBHBHB
HBHB
19' - 0" 19' - 0"
19' - 0" 19' - 0"
OMNI OMNI
HPS HPS
HPS
HPS
TT TT
BRK BRK
7' - 0" 7' - 0"
CL CL CL CL
7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0"
7' - 0" 7' - 0"
CL CL CL CL
7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0"
2' X 2' LIGHT FIXTURE. COORD. W/
LIGHTING FIXT. SCHED.
SUSPENDED STEM MTD. FIXTURES.
COORD. W/ LIGHTING FIXT. SCHED.
RECCESED CAN DOWNLIGHT.
COORD. W/ LIGHTING FIXT. SCHED.
LEGEND - RCP
SUSPENDED HI-BAY STEM MTD.
FIXTURES. COORD. W/ LIGHTING FIXT.
SCHED.
CEILING FAN LOCATION. COORD. W/
EQUIPMENT SCHEDULE
RETURN AIR GRILLE. COORD. W/
MECH. DWGS.
SUPPLY AIR DIFFUSER. COORD. W/
MECH. DWGS.
EQ EQ
E Q
E Q
FANS SPEAKER SYSTEM
FANS COLOR INDICATOR
FINISH CLG. HEIGHT
CEILING ASSEMBLY
2' X 2' LIGHT FIXTURE - EMER.
POWER. COORD. W/ LIGHTING FIXT.
SCHED.
SPEAKER
EQ EQ
E Q
E Q
WALL SCONCE. COORD. W/ LIGHTING
FIXT. SCHED.
DOME PENDANT. COORD. W/
LIGHTING FIXT. SCHED.
CEILING ACCESS PANEL -
CONTRACTOR TO CONFIRM ALL
QUANTITIES AND LOCATIONS
SOLID GRAY WALLS INDICATE
PARTITIONS THAT EXTEND UP TO
ROOF OR FLOOR STRUCTURE ABOVE
SPECIFIC EQUIPMENT NOTES
1. FURNISHINGS/ EQUIPMENT PROVIDED BY OWNER WHERE INDICATED IN EQUIPMENT SCHEDULE. GC
SHALL COORDINATE DELIVERY OF FURNISHINGS/ EQUIPMENT BY OWNER. GC TO PROVIDE BLOCKING OR
LG STRAPPING IN PARTITION AS REQUIRED FOR INSTALLATION.
2. PROVIDE ARCTIC PURE WATER FILTRATION SYSTEM. COORD. W/ PLUMB.
3. GRILL TO BE PROVIDED WITH CASTER AND IGNITER.
4. OWNER TO PROVIDE EXISTING SLIDE POLE FROM EXISTING STATION. CONTRACTOR TO FIELD CUT TO
LENGTH POLE AND MOUNT PER ARCHITECTURAL DETAILS.
5. PROVIDE EXTRA HEAVY DUTY ROUGH IN CONNECTIONS.
6. EXHAUST TO EXTERIOR. COORD. W/ MECH.
7. PROVIDE 75' LENGTH OF 1/2" 300 PSI COUPLED ASSEMBLY MULTI-PURPOSE AIR HOSE WITH BALL STOP
FOR EACH AIR HOSE REEL WITH A QUICK DISCONNECT END. COORD. W/ PLUMB.
8. PROVIDE 35' LENGTH OF SELF RETRACTING ELECTRICAL POWER CORD WITH BALL STOP FOR EACH
ELECTRICAL CORD REEL. CORD REEL DROPS ARE NOT TO INTRUDE ON APPARATUS BAY DRIVE LANE WIDTH. CONTRACTOR TO COORD. DROPS OF CORD REELS WITH OTHER EQUIPMENT/ SYSTEMS DURING CONSTRUCTION AND NOTIFY ARCHITECT OF POTENTIAL CONFLICTS PRIOR TO INSTALL. PROVIDE 5'
BREAK AWAY CORD CONNECTION AT THE END OF THE REEL.
9. PROVIDE 75' LENGTH OF 1" HOSE FOR EACH WATER HOSE REEL WITH 3/4" FIRE HOSE NOZZLE GRAINGER
MODEL 6AKC6.
10. PROVIDE SPECIFIED FIRE EXTINGUISHER FOR EACH CABINET.
11. PROVIDE LED WARNING LIGHTS FOR EACH APPARATUS BAY OPENING. COORDINATE POWER WITH ELEC.
DRAWINGS. LOCATE WARNING LIGHTS PER ARCHITECTURAL ELEVATIONS.
12. APPARATUS BAY VEHICLE DOORS SHALL BE OPERATED BY CONTROL BUTTONS LOCATED PER
ARCHITECTURAL INTERIOR ELEVATIONS. PROVIDE MANUAL RELEASE AT EACH DOOR PER
MANUFACTURER DATA. SEE ELEC. DRAWINGS FOR WIRING CONTROL DIAGRAM. .
13. PROVIDE WALL MOUNTED AND TUBULAR FRAME FREE STANDING LOCKERS AS SHOWN ON PLANS.
14. ELECTRIC TROLLEY HOIST TO BE PROVIDED WITH MISCELLANEOUS STEEL HOSE HOOK. REFER TO HOSE
TOWER DETAILS. COORD. W/ ELEC DRAWINGS FOR POWER REQUIREMENTS
15. PROVIDE ADA ACCESSIBLE LOCKER FOR LOCKERS INDICATED ON PLAN/ INTERIOR ELEVATIONS.
16. PROVIDE LG BLOCKING FOR TV MOUNT IN ACCORDANCE WITH INTERIOR DETAILS SHEET.
17. PROVIDE ANODIZED ALUMINUM TRIM FOR MARKERBOARD AND TACKBOARD. MAP RAIL WITH DISPLAY
RAIL TO BE INCLUDED ON TACKBOARD AND WHITEBOARD ASSEMBLY.
18. COORD. W/ MECHANICAL
19. PROVIDE EASY CLEAR® EQHP-10 FILTRATION SYSTEM. COORD. W/ PLUMB
20. PROVIDE ADA SWITCHES FOR RANGE HOOD MOUNTED TO FRONT OF BASE CABINET. PROVIDE MANUAL
PULL STATION OPTION AT HOOD.
21. REFER TO STRUCTURAL DRAWINGS FOR ADDITIONAL STEEL REQUIRED FOR FAN ATTACHMENT TO
JOISTS. FAN TO BE MOUNTED AT PANEL POINT ON JOIST. REFER TO ELECTRICAL DRAWINGS FOR FIRE
ALARM INTERLOCK.
22. PROVIDE STEEL PEGBOARD STARTER KIT AND PEGBOARD MOUNTING HARDWARE.
23. PROVIDE 6,000 PSI HOSE 1/2" I.D. 125 FOOT LENGTH FOR THE SCBA HOSE REEL.
24. GC TO PROVIDE 2" THICK, 32" DIAMETER CLOSED CELL BLACK NEOPRENE LANDING MAT FOR BOTH
OWNER PROVIDED FIRE POLES
25. CIP CONCRETE BASE TO BE PROVIDED WITH EQUIPMENT.
26. ENERGY STAR RATED APPLIANCE. COORDINATE WITH SPECIFICATIONS.
27. PROVIDE DRYER VENT EXHAUSTED TO EXTERIOR PER MECHANICAL DWGS. VENT TO BE CONCEALED
WITHIN WALL. LINT TRAP TO BE MOUNTED TO FLOOR AT ACCESSIBLE LOCATION ADJACENT TO DRYER.
EQUIPMENT SCHEDULE NOTES
GENERAL NOTES:
A. PROVIDE AND INSTALL ALL EQUIPMENT OF THE MANUFACTURER & MODEL NUMBERS LISTED IN
SCHEDULE & ON DRAWINGS. EQUIPMENT LISTED IN SCHEDULE IS BASIS OF DESIGN; ANY SUBSTITUTIONS WILL REQUIRE APPROVAL FROM A/E AND OWNER. FOR ITEMS NOT INCLUDED IN SPECIFICATIONS, PROVIDE SUBMITTALS PER SPEC SECTION 01 33 00 AND SUBMITTED UNDER CSI DIVISION PER CSI MASTERFORMAT. FOR ITEMS WHICH HAVE BEEN DISCONTINUED OR CHANGE IN MODEL NUMBER BY THE TIME OF ACQUISITION, PROVIDE ITEM OF EQUIVALENT PERFORMANCE FOR A/E AND OWNER APPROVAL.
B. REFER TO EQUIPMENT SCHEDULE FOR NOTES APPLICABLE TO EACH PIECE OF EQUIPMENT.
FIRE STATION ALERTING SCOPE
1. STAFFORD COUNTY FIRE STATIONS USE A PROPRIETARY ALERT NOTIFICATION SYSTEM: “WESTNET FIRST
IN”. THE STATION ALERTING SYSTEM WILL BE A TURNKEY DELIVERY THROUGH THE GENERAL
CONTRACTOR. THE GENERAL CONTRACTOR IS TO CONTRACT DIRECTLY WITH WESTNET FOR THIS
TURNKEY DELIVERY, AND INCLUDE PRICING FOR THE FULL DELIVERY OF THE STATION ALERTING SYSTEM IN THEIR BID. THE GENERAL CONTRACTOR IS TO PROVIDE ALL INFRASTRUCTURE REQUIRED TO FACILITATE A FULLY FUNCTIONING STATION ALERTING SYSTEM PER THE WESTNET DRAWINGS INCLUDED
WITH DEVICES TO SUPPORT STATION ALERTING SYSTEM.
A. PROVIDE COMMUNICATIONS RACK REQUIRED TO SUPPORT STATION ALERTING SYSTEM.
2. SCOPE OF WORK UNDER STATION ALERTING TURNKEY DELIVERY:
A. PROVIDE ALL DEVICES INCLUDED ON WESTNET DRAWINGS INCLUDED WITH…
This is the start of the file's text. The full file is on GovTribe.