Attachment 7 - TECH 012 Example.pdf

PDF 6 MB Posted

Attached to
Temporary Facility Lease Federal contract opportunity
Solicitation number
FA558722Q0041
Issued by
Department of the Air Force United States Air Forces in Europe - Air Forces Africa

View the file

Other files for this federal contract opportunity

Other files attached to Temporary Facility Lease, newest first.
File Type Posted
Amendment 08 - FA558722Q0041.pdf PDF
Statement of Work 08 Aug 2022.docx DOCX document
Attachment 9 Project 2 indicative floor plan.pptx PPTX presentation
Amendment 07 - FA558722Q0041.pdf PDF
Amendment 06 - FA558722Q0041.pdf PDF
Attachment 9 Project 2 indicative floor plan.pptx PPTX presentation
Statement of Work 22 July 2022.docx DOCX document
Attachment 8 Project 1 indicative floor plan.pptx PPTX presentation
Amendment 05 - FA558722Q0041.pdf PDF
Attachment 2- Offer Sheet.pdf PDF
Statement of Work 08 July 2022.docx DOCX document
Amendment 04 - FA558722Q0041.pdf PDF
Amendment 03 - FA558722Q0041.pdf PDF
Amendment 02 - FA558722Q0041.pdf PDF
Amendment 01 - FA558722Q0041.pdf PDF
Attachment 2- Offer Sheet.pdf PDF
Statement of Work 15 June 2022.docx DOCX document
Attachment 3 - DE USF 141 - Provide Allied Support PMO Facility.pdf PDF
Solicitation - FA558722Q0041.pdf PDF
Attachment 2- Offer Sheet.pdf PDF
Attachment 6 - DE USF 141 - Provide Allied Support PMO Facility.pdf PDF
Attachment 4 - Example of a Combined Fire Strategy - Redacted.pdf PDF
Statement of Work 21 April 2022 - Final.docx DOCX document
Attachment 5 - Tech-012 Handover Process for Works Projects V0.1.pdf PDF
Attachment 2 - 20170421-D2C_New_Works_Compliance_Guide.pdf PDF
Attachment 1 - MOD Building Regs Policy Instruction 02-10.pdf PDF
Show all 26

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Form DE USF 40 (05/99) Defence Estates is an Agency of the MOD

Project Title: Renovation of Burger King RAF Lakenheath

Project No: LAK11-2006

CERTIFICATE AT COMPLETION OF DESIGN (DE2)

I hereby certify that the Specification and Drawings are complete and are now the property of MOD and are suitable in all respects to:-

(1) achieve the requirements of the Design Brief;

(2) form part of the documentation for the tendering of the Works Contract with

Authority's Design, such that the tenders are submitted on a basis which is fair and provides for technical equivalence;

(3) form part of the Contract for the Works Contract with Authority's Design; and

(4) be capable of successful implementation under the Works Contract with

Authority's Design without the issue of further design information that would result in a Change to the Works Contract.

Signed:

Name (Capitals): Darren Fowler

Name of Firm: Templeman Design

Position in Firm: Associate Director

Date: July 2013

Vinci Form 45 (06/2013)

VINCI FACILITIES – BUILDING SOLUTIONS EAST – FSC2 DESIGN

CERTIFICATE OF COMPLIANCE WITH THE CDM REGULATIONS

AT DESIGN STAGE

To be submitted to the:

DESIGN MANAGER

Copied to:

Design Coordinator Technical Manager Construction Manager

By the CDM Coordinator on completion of the design.

Location: RAF Lakenheath

Project No: MIL12-1018

Project Title: Renovation of Burger King

During the design review process health and safety aspects have been checked to ensure that compliance of Regulation 11 has been addressed, also that health and safety issues have been addressed alongside practicality in a wider review of the design’s buildability, maintainability and usability, also consideration has been given to the health and safety of those who will maintain and use the structure once it has been completed.

During the design process it has been ensured that the designers have identified a safe method for construction, and that the designs include the information needed by other designers and contractors to allow them to work safely and without risk to health.

Signed:

Name (Capitals): A M SHAW

Name of Firm: MLM Consulting Engineers Ltd

Position in Firm: CDM Coordinator

Date: 7 May 2013

Form DE USF 67 (09/03) Page 1 of 2

CERTIFICATE OF COMPLIANCE WITH THE BUILDING REGULATIONS AT

DESIGN STAGE

To be submitted to the:

Building Control Officer

DE USF

Stirling House Denny End Road Waterbeach CB5 9QB

Copied to:

DE USF Project Sponsor DE USF Fire Advisor

By the Building Control Adviser on completion of the design.

Location: Burger King, RAF Lakenheath

Project No: LAK11-2006

Project Title: Renovation of fast food restaurant

Not withstanding anything to the contrary in this certificate, this firm is obliged to exercise all reasonable skill, care and diligence in the performance of the services required by this works service and this firm shall not be liable except to the extent that it failed to exercise all reasonable skill, care and diligence and this certificate shall be construed accordingly.

I certify that the design produced for the works services have been examined by a competent professional person not involved in the design process to see that all reasonable skill, care and diligence has been exercised in the development of these designs and that:

a. The design principles, the design calculations and drawings produced conform with the substantive requirements of the Building Regulations, the Crown Fire Standards, the Water Supply (Water Fittings) Regulations and any other associated legislation, current during the design development.

b. The calculations produced have been carried out correctly.

c. The structural design and calculations have been submitted for a third party appraisal, the findings of which are contained in the Structural Design Compliance Certificate.

BUILDING CONTROL ADVISERS DETAILS

Signed: BCA Qualification: BSc (Hons) FRICS MIFireE

Name (in Capitals): JASON WHITE

Name of Firm: MLM Building Control Position in Firm: Technical Director

Address: Building 7200 Date: 5th September 2013

Cambridge Research Park

Cambridge, CB25 9TL

Telephone No: 01223 815561

Form DE USF 67 (09/03) Page 2 of 2

This certificate shall not be read as implying certification of the Design or the Works as defined in the Building Act 1984 and the Building (Approved Inspectors etc.) Regulations 2000, associated legislation or the National equivalent.

COMPLIANCE OF DESIGN CERTIFICATE

(England and Wales)

Building Regulations Requirement

Date of receipt of determination/waiver

Date checked and Certified

Comments

Structure (see also Structural Design Compliance Certificate)

N/A N/A

Fire Safety (Provide Certification A or B as appropriate)

16th August 2013 4th September 2013

There is no requirement to compartment the toilet areas nor is there a requirement to show a 60 minute compartment line around the perimeter of the building. To do so indicates that all the perimeter glass is fire rated.

Site preparation and resistance to moisture

N/A N/A

Toxic substances N/A N/A

Resistance to the passage of sound

N/A N/A

Ventilation 16th August 2013 4th September 2013

Hygiene 16th August 2013 4th September 2013

Drainage and waste disposal

16th August 2013 4th September 2013

Heat producing appliances

16th August 2013 4th September 2013

Protection from falling, collision and impact

16th August 2013 4th September 2013

Conservation of fuel and power

16th August 2013 4th September 2013

Access and facilities for disabled people

16th August 2013 4th September 2013

Glazing – safety in relation to impact, opening and cleaning

16th August 2013 4th September 2013

Form DE USF 67 (09/03) Page 3 of 2

Regulation 7 Materials and workmanship

16th August 2013 4th September 2013

Building Act 1984 S15/Fire Precautions Act 1971 ss 15-17 or national equivalents

N/A N/A

FIRE SAFETY WORKS

HS

HS

HS

HS

HS

HS

HS

HS

HS

HS

HS

HS

HS

HS

HS HS

HS

HS

HS

HS

HS

HS

HS

HS

HS

HS

HS

HS

HS

HS

HS

FD60S

VP

DC

FD60S

VP

DC

EXTERNAL

PB

EXTERNAL

PB

EXTERNAL

PB

EXISTING

NONFD

NONFD

PP

DC

NONFD

PP

DC

FD60S

VP

DC

SL

FD60S

VP

DC

SL

FD60S

VP

DC

SL

FD60S

VP

DC

SL

EXISTING

EXISTING

EXISTING

EXISTING

EXISTING

EXISTING

FD60S

VP

DC

SL

EXTERNAL

EXTERNAL

HS

AUTOMATIC FIRE SENSOR

MODE SETTINGS

FIRE SYMBOLS FIRE COMPARTMENT / ESCAPE

NOTES:

Do not scale this drawing (printed or electronic versions)

Contractors must check all dimensions from site

This drawing is copyright and is for use on this site only

All structural, mechanical & electrical elements, where indicated, have been imported from the engineers drawings and reference should be made to the individual engineers drawings for exact setting out, size and type of component.

This drawing should be read in conjunction with all relevant consultants and specialist sub-contractor, supply chain drawings and specifications.

Discrepancies and/or ambiguities within this drawing, between it and information given elsewhere, must be reported immediately to this office for clarification before proceeding.

All works to be carried out in accordance with the latest

British Standards/Codes of Practice unless specifically directed otherwise in the specification.

Responsibility for the reproduction of this drawing in paper form, or if issued in electronic format, lies with the recipient to check that all information has been replicated in full and is correct when compared to the original paper or electronic image.

Graphical representations of equipment on this drawing have been co-ordinated, but are approximations only.

Please refer to Specifications and / or Details for actual sizes and or specific contractor construction information

INTERNAL WORKS - RENOVATION OF BURGER KING RAF LAKENHEATH

OtherAs-Built

PROJECT No.

Originating Office of Drawing

PROJECT TITLE

DRAWING TITLE

DATE

DATE

DATE

Scale

Drawing No.

Sheet

Fabrication

POST CONTRACT

65% 100%

DESIGNED BY

Site Location

DRAWN BY

CHECKED BY

CAD File No.

* Classified

* Unclassified

Prelim

Contract No.

PROJECT/CONTRACT STATUS

SECURITY CLASSIFICATION

PRE CONTRACT

Tender

PROJECT MANAGER

AMENDMENTS

DATE BY CKD/APD

DETAILS

REF

CONTRACTOR LEAD DESIGNER

United

States

Forces

CONTRACTORCONTRACTOR

LAK11 - 2006

INTERNAL WORKS

RENOVATION OF BURGER

KING BUILDING 952

FIRE COMPARTMENT AND

ESCAPE ROUTE PLAN

FS001

1:50 @ A1

TEMPLEMAN DESIGN

JAMES COUPE

DPF

OCT 12

CJH

OCT 12

DPF

OCT 12

DE USF 12124

CONSTRUCTION ISSUE

FIRE COMPARTMENT AND ESCAPE ROUTE PLAN

FIRE SAFETY WORKS

EM

EM

EM

SP

A A A A AA

A

A

A

A

A

A

B

EM

EM

EM

EM

EM

EM

EM

EM

SP

SP

A

A

A

EM

C

C

C

C

C

C

C

C

C

C

C

C

SP

SP

SP

EM

C

C

C C

F

EM

EM

EM

EM

EM

EM

EM

EM

EM

EM

EM

EM

EM

EM

G

G

G

G

G

G

EM

EM

EM

EM

EM

EM

EM

EM

EM

EM

EM

EM

EM

EM

EM

EM

EM

EM

EM

EMEM

CCT:-A/1L1

CCT:-A/1L3

CCT:-A/2L3

CCT:-A/7L1

CCT:-A/3L3

CCT:-A/3L1

CCT:-A/3L1

D

D

D

D D D D D

D

D

D D D

D

D

D

D

D

D D

D

D D D

D

D

D

D D D D

D

D

D

H

H

EM

EM

EM

EM

EM EM

EM

EM

EM

EM

EM

EM

EM

EM EM EM

EM

EM

EM

EM

EM

EM

EM

EM

EM EM

EM

EM

EM

EM

EM

EM

EM

EM

EM

EM

D K

K

EM EM

EM

EM

B

C

A

SCHEDULE OF PROPOSED LUMINAIRES

Fire exit

G

F

Tx

SCHEDULE OF PROPOSED LUMINAIRES

Tx

Tx

SCHEDULE OF PROPOSED LUMINAIRES

NOTES:NOTES:

Do not scale this drawing (printed or electronic versions)

Contractors must check all dimensions from site

This drawing is copyright and is for use on this site only

All structural, mechanical & electrical elements, where indicated, have been imported from the engineers drawings and reference should be made to the individual engineers drawings for exact setting out, size and type of component.

This drawing should be read in conjunction with all relevant consultants and specialist sub-contractor, supply chain drawings and specifications.

Discrepancies and/or ambiguities within this drawing, between it and information given elsewhere, must be reported immediately to this office for clarification before proceeding.

All works to be carried out in accordance with the latest

British Standards/Codes of Practice unless specifically directed otherwise in the specification.

Responsibility for the reproduction of this drawing in paper form, or if issued in electronic format, lies with the recipient to check that all information has been replicated in full and is correct when compared to the original paper or electronic image.

Graphical representations of equipment on this drawing have been co-ordinated, but are approximations only.

Please refer to Specifications and / or Details for actual sizes and or specific contractor construction information

INTERNAL WORKS - RENOVATION OF BURGER KING RAF LAKENHEATH

LA

OtherAs-Built

PROJECT No.

Originating Office of Drawing

PROJECT TITLE

DRAWING TITLE

DATE

DATE

DATE

Scale

Drawing No.

Sheet

Fabrication

POST CONTRACT

65% 100%

DESIGNED BY

Site Location

DRAWN BY

CHECKED BY

CAD File No.

* Classified

* Unclassified

Prelim

Contract No.

PROJECT/CONTRACT STATUS

SECURITY CLASSIFICATION

PRE CONTRACT

Tender

PROJECT MANAGER

AMENDMENTS

DATE BY CKD/APD

DETAILS

REF

CONTRACTOR LEAD DESIGNER

United

States

Forces

CONTRACTORCONTRACTOR

LAK11 - 2006

INTERNAL WORKS

RENOVATION OF BURGER

KING BUILDING 952

ESCAPE ROUTE, GENERAL

AND EMERGENCY LIGHTING

FS002

1:50 @ A1

TEMPLEMAN DESIGN

JAMES COUPE

DPF

OCT 12

CJH

OCT 12

DPF

OCT 12

DE USF 12124

ESCAPE ROUTE, GENERAL AND EMERGENCY LIGHTING

NOTES:NOTES:

Do not scale this drawing (printed or electronic versions)

Contractors must check all dimensions from site

This drawing is copyright and is for use on this site only

All structural, mechanical & electrical elements, where indicated, have been imported from the engineers drawings and reference should be made to the individual engineers drawings for exact setting out, size and type of component.

This drawing should be read in conjunction with all relevant consultants and specialist sub-contractor, supply chain drawings and specifications.

Discrepancies and/or ambiguities within this drawing, between it and information given elsewhere, must be reported immediately to this office for clarification before proceeding.

All works to be carried out in accordance with the latest

British Standards/Codes of Practice unless specifically directed otherwise in the specification.

Responsibility for the reproduction of this drawing in paper form, or if issued in electronic format, lies with the recipient to check that all information has been replicated in full and is correct when compared to the original paper or electronic image.

Graphical representations of equipment on this drawing have been co-ordinated, but are approximations only.

Please refer to Specifications and / or Details for actual sizes and or specific contractor construction information

INTERNAL WORKS - RENOVATION OF BURGER KING RAF LAKENHEATH

OtherAs-Built

PROJECT No.

Originating Office of Drawing

PROJECT TITLE

DRAWING TITLE

DATE

DATE

DATE

Scale

Drawing No.

Sheet

Fabrication

POST CONTRACT

65% 100%

DESIGNED BY

Site Location

DRAWN BY

CHECKED BY

CAD File No.

* Classified

* Unclassified

Prelim

Contract No.

PROJECT/CONTRACT STATUS

SECURITY CLASSIFICATION

PRE CONTRACT

Tender

PROJECT MANAGER

AMENDMENTS

DATE BY CKD/APD

DETAILS

REF

CONTRACTOR LEAD DESIGNER

United

States

Forces

CONTRACTORCONTRACTOR

LAK11 - 2006

INTERNAL WORKS

RENOVATION OF BURGER

KING BUILDING 952

FIRE BRIGADE ACCESS AND

FIRE HYDRANT LOCATIONS

FS003

1:1250 @ A1

TEMPLEMAN DESIGN

JAMES COUPE

DPF

OCT 12

CJH

OCT 12

DPF OCT 12

DE USF 12124

FIRE BRIGADE ACCESS AND FIRE HYDRANT LOCATIONS

Fire Strategy Assessment Renovation of Burger King RAF Lakenheath

Templeman Design - 2 North Lynn Business Village - Bergen Way - King’s Lynn - Norfolk PE30 2JG

Telephone: (01553) 776148 - Fax: (01553) 778320 - Email: enquiries@templemandesign.com - Web: www.templemandesign.com

FIRE STRATEGY ASSESSMENT

FOR

RENOVATION OF BURGER KING

AT

RAF LAKENHEATH

Construction Issue

Internal Works

FIRE STRATEGY ASSESSORS DETAILS

Name (in Capitals): Richard Rankin Qualification: CEng MEng (Hons) MIFireE

Position : Associate Date: 28TH November 2012 mailto:enquiries@templemandesign.com http://www.templemandesign.com/

RAF Lakenheath

Telephone: (01553) 776148 - Fax: (01553) 778320 - Email: enquiries@templemandesign.com - Web: www.templemandesign.com

Project Specific Fire Strategy Document

Section “A” Overview of the Project Details

Location; RAF Lakenheath Project Title; Renovation of Burger King Project Number; 2928

• Brief description / scope of the overall project

The project will include for the renovation of Burger King at RAF Lakenheath. It will include the renovation of the restaurant and washroom interior to match the new 20/20 design criteria. The project will include for the renovation of the external façade of the building to match the new 20/20 design criteria.

The renovation project will also extend into the kitchen, of which will include for new kitchen wall, floor and ceiling finishes in accordance with the 20/20 design criteria.

The ‘back of house’ works will also include the relocation of the kitchen office to provide a separate compartment close to an external fire escape to minimise entrapment. The existing office will become a new store provided with new fire doorset in accordance with the 20/20 design criteria. Other doors leading off of the kitchen will also be replaced to provide a 60minute fire compartment and finish in accordance with the 20/20 design criteria.

The ‘back of house’ works will also include the replacement of existing internal freezer and chiller units.

An additional fire escape from the rest room has also been provided to allow staff to escape directly from the rest room rather than passing through the existing kitchen.

Throughout the work areas new general and emergency lighting shall be provided.

Illuminated exit signage and external emergency lighting shall also be provided.

• Non compliance issues

An additional fire escape from the rest room was requested and has been included within the project. The existing fire detection system has also been replaced in July 2011 by Global Fire and therefore no upgrade or improvement works have been included within this project, on localised modification and extension to suit new layouts and ceiling features.

RAF Lakenheath

Telephone: (01553) 776148 - Fax: (01553) 778320 - Email: enquiries@templemandesign.com - Web: www.templemandesign.com

• UFC Project Classification

The project is classified as a renovation.

UFC 3-600-01 UFC 3-600-1 Change 1 14 July 2009 Appendix B has been used to determined the project classification for this project, of which has been identified as ‘Ordinary Hazard Group 1 Occupancies’

“Occupancies or portions of occupancies where combustibility is low, quantity of combustibles is moderate, stockpiles of combustibles do not exceed 2.5 m (8 ft), and fires with moderate rates of heat release are expected. Modest, scattered amounts of flammable liquid, in closed containers are allowable in quantities not to exceed 75 L (20 gal) per fire area. This classification includes but is not limited to the following occupancies:

• Armories

• Sheet metal shops

• Bowling alleys

• Ship fitting shops

• Clubs (officer, enlisted personnel, etc.)

• Kitchens and bakery

• Small stores

• Theaters and auditoriums

• Welding shops

• Forge shops

• Laundries

• Automobile parking garage

• Electronics assembly and repair

• Building Classification

NFPA 101 Life Safety Code, chapter 6, has been used to determine the building classification, of which this project falls into the classification of ‘Assembly’.

6.1.2.1 Definition – Assembly Occupancy. An occupancy used for gathering of 50 or more persons for deliberation, worship, entertainment, eating, drinking, amusement, awaiting transportation or similar uses.

• Purpose Group

Appendix D: Purpose Groups of the current Building Regulations would suggest that this building would fall under group 4 which is Shops and Commercial.

Shops or premises used for retail trade or business (including the sale to members of the public of food or drink for immediate consumption and retail by auction, self selection and over the counter wholesale trading, the business of lending books or periodicals for gain and the business of a barber or hairdresser and the retail of storage space to the public).

Telephone: (01553) 776148 - Fax: (01553) 778320 - Email: enquiries@templemandesign.com - Web: www.templemandesign.com

Fire Strategy Assessment

RAF Lakenheath

• Occupation of the Facility

The building occupation provides seats for 119 persons in the restaurant with an expected number of 15 staff members working within the service area, kitchen and stores.

• Mission Essential Facilities

The building is not mission essential

• Size of Facility

The existing building is 415m2 and will not be increasing in size as part of the works.

• Number of Floors and Height of Facility

The facility is single storey with no upper floors, mezzanines or roof voids.

• Type of Construction

The building mainly comprises of a masonry structure topped with supporting king trusses. The remainder of the structure is steelwork infilled with curtain walling.

There is a combination of pitched and flat roofs.

External doors and windows are aluminium.

• Existing Fire Deficiencies (Form 1487)

Form 1487 has been requested, however at present it has not been received.

• Previous Fire Review Comments

No previous fire officer comments

Telephone: (01553) 776148 - Fax: (01553) 778320 - Email: enquiries@templemandesign.com - Web: www.templemandesign.com

Fire Strategy Assessment

Section “B” Fire Strategy based on the CISBE Guide E

a) Introduction.

The facility operates as a fast food outlet with a combination of eating in, take away and drive thru options.

50% of the building is dedicated to customers with various seating areas and washroom facilities. The remaining 50% is dedicated to the Kitchen, Food Storage, Office and staff faculties.

There are two main forms of cooking involved. There are two deep fat fryers (one is redundant and will be removed as part of this project) and broiler in existence, both are provided with Ansul Protection.

There is two means of escape from the restaurant which lead directly outside, and there are two means of escape from the kitchen and back of house facilities. One leads directly outside and the other escape is through the restaurant area. As part of this project it is proposed an additional fire escape is added to improve fire safety measures from the staff rest room.

b) Project

The project includes for the interior and exterior renovation of the facility. The only spaces that are not included within the refurbishment are the staff and storage areas.

A majority of the works include the replacement of finishes. Existing fixtures and furniture are being replaced within the restaurant and customer washrooms only.

The project includes for the replacement of general and emergency lighting throughout the work areas. This also includes the replacement and addition of illuminated exit signage and external emergency lighting.

The project includes for the addition of a fire escape from the staff rest room reducing the risk of entrapment and escape through a high risk area.

(Kitchen).

The works include the removal of one existing fryer hood which includes the removal of a Suppression System supply. The works also include for the replacement of the broiler hood to improve cleanliness. This will include for the installation of new suppression system within the hood which will be connected to the existing Ansul Suppression System.

Existing doors within the work areas will also be replaced improving the aesthetics as well as improving fire compartments and vision.

Telephone: (01553) 776148 - Fax: (01553) 778320 - Email: enquiries@templemandesign.com - Web: www.templemandesign.com

Fire Strategy Assessment

c) Sources of information

Reference Title A. BS7671:2008 - Institution of Electrical Engineers Wiring Regulations-17th Edition

Incorporating Amendment No 1: 2011 B. United States National Electrical Code (NEC) Article 810.21.

C. National Fire Protection Association – NFPA 70: 2011 – National Electrical Code.

D. BS 7430: 1998 - Code of Practice for Earthing.

E. MIL-STD 188-124B: 1992 Grounding, Bonding and Shielding, Military Standard.

F. HD637 S1: 1999 – Section 9 – Standard Earthing Practice.

G. Defence Estates – Specification 034 (Edition No.1) - Electrical Installations.

H. Electrical Safety Rules and Procedures (JSP375, Volume 3, Chapter 3) I. Unified Facilities Criteria – UFC 3-600-01.

J. Crown Fire Standards (CFS) Issue 1 – Rev 1: 1998.

K BS 5839: Part 1: 2002 – Fire Detection and Alarm Systems for Buildings.

M. National Fire Protection Association – NFPA 72: 2010 – National Fire Alarm Code N. National Fire Protection Association – NFPA 101: 2012 – Life Safety Code.

O. Chartered Institution of Building Services Engineers (CIBSE) – Guide E – Fire

Engineering.

P. DEUSF TECH 010 – Jan 2009.

Q. BS476: Part 22: 1987 – Fire tests on Building materials and structures. Methods for determination of the fire resistance of non-load bearing elements of construction.

R. BS 8434: Part 1: 2003 – Methods of test for assessment of the Fire Integrity of Electrical cables. Test for unprotected small cables for use in Emergency circuits. BS EN 50200 with addition of water spray.

S. BS 8434: Part 2: 2003 - Methods of test for assessment of the Fire Integrity of Electrical cables. Test for unprotected small cables for use in Emergency circuits. BS EN 50200 with 930oC flame and with water spray.

T. BS 5266, Part 1: 2011 – British Standard Code of Practice for Emergency Lighting.

U. BS 5499: 2002 – Specification for Exit Signs V. Health and Safety – Safety Signs and Signals Regulations: 1996.

W. The Accessibility Standard for DE Facilities (ABA).

X. Equality Act 2010 Y. BS 8300: 2001 – Design of Buildings and their approaches to meet the needs of Disabled

People.

Z. BS 9999: Oct 2008 – Code of Practice for the fire safety in the design Management and

Use of buildings AA. AFOSH STD 91-501 Clause 6.2.2.1 AB NFPA 5000 Building Construction and Safety Code 2012 AC NFPA 1221 Installation, Maintenance and Use of Emergency Services Communication

Systems 2010 AD NFPA 75 Standard for the Protection of Information Technology Equipment: 2009 AE Fire Protection for Electronic Data Processing Installations: BS 6266:2011 AF BSEN 62305 Lightning Protection Standards 2006 AG JSP 317 Storage and Handling of Fuels AH NFPA 13 Standard for the Installation of a Sprinkler System 2010 AJ BSEN 12845: 2004 + A2: 2009 Fixed Firefighting Systems. Automatic Sprinkler Systems.

Design, Installation & Maintenance.

AK Defence Estates United States Forces Fire safety Signs Report Nov 2006.

RAF Lakenheath

Telephone: (01553) 776148 - Fax: (01553) 778320 - Email: enquiries@templemandesign.com - Web: www.templemandesign.com

d) Means of Escape

An existing fire strategy and risk assessment has been requested; however it has not been provided or does not exist. The fire strategy drawing FS001 and FS002 has been produced and is based upon assumed fire escape routes and construction of walls, doors, window, opening protection in order to assess compartments.

We are improving travel distances to exits by provide an additional external fire escape from the staff rest room. This removes inner room scenarios and prevents staff escaping through high risk areas (kitchen).

e) Fire Spread Control

An existing fire strategy and risk assessment has been requested; however it has not been provided or does not exist. The fire strategy drawing FS001 and FS002 has been produced based upon assumed compartments and the rating of those compartments has been based upon the examination of existing components. For example if an internal wall is masonry and it is full height we can assume a fire rating of at least 1 hour.

f) Design Fires

As the fire strategy relies on compliance with prescriptive standards and not a fire engineered solution, design fires are not relevant.

g) Facilities for the Fire Brigade

The existing building is well served by a network of roads and wide footpaths whereby a fire tender can gain access to within 10m of the building. There are also fire hydrants within 100 meters of the existing building. Fire tender and hydrant locations can be seen on drawing FS003.

h) Fire Systems

i. Smoke Control

An existing smoke control strategy has not been provided but it is assumed that the existing strategy for the building is for the fire service to clear rooms and voids of smoke manually with portable fan equipment. After the fire is extinguished smoke can be vented via the external doors & windows with the assistance of the supply air ventilation system which can be operated independently via the fireman’s control panel from the mechanical control panel.

ii. Sprinkler Systems

The building is not protected by a sprinkler system. However, it is protected by fire detection measures, and the cooking equipment is protected with a Ansul R-102 suppression system linked through to the fire alarm upon activation.

Telephone: (01553) 776148 - Fax: (01553) 778320 - Email: enquiries@templemandesign.com - Web: www.templemandesign.com

Fire Strategy Assessment Renovation of Burger King

iii. Alarm System

The Existing Fire Alarm system has been retained and information provided to give the contractor guidance regarding the setting of the multi-functional detectors, minor amendments have been indicated to suite the operational needs of the facility. Full detection under US regulations is required. Sound levels of 75db required to all areas

iv. First-aid fire fighting

An existing fire plan has not been provided. Some areas have fire extinguishers provided for small fire fighting and positions are located on drawing FS001.

v. Emergency Lighting

Compliance with US standards of average of 10.8 lux in all escape routes with a minimum requirement of 1 lux. Within the Kitchen B.S 5266_1:2011 is more onerous and a minimum illumination level of 15 Lux is required. LED maintained signs have been indicated over exits.

i) Role of Management

The building management shall incorporate/consider building layout changes and revise their management system/fire strategy as necessary. It should be noted that no fire risk assessment for the building has been made available for this project.

j) Cooking Equipment

This project does not include the supply of cooking equipment however is does include the replacement of the extract canopy/hood over the Broiler.

The hood is constructed to NFPA 96 standards and includes integral Ansul R- 102 Fire suppression pipework and nozzles linked to the existing Ansul R-102 systems. In the event of a fire at the broiler, the thermal link will activate the Ansul system suppressing the fire locally. The Ansul system also interfaces with the fire alarm panel and will activate the alarm. This in turn will interface with the BMS/ Mechanical Control panel ( to be replaced under separate project DIO Project number MSET L6098) which will interface with the new gas safety panel which will activate the gas solenoid valve which will close and shut-off the supply of gas to the cooking equipment.

k) Fire Hydrants

Fire hydrant are not included within this projects scope of works.

RAF Lakenheath

l) Ventilation System

Telephone: (01553) 776148 - Fax: (01553) 778320 - Email: enquiries@templemandesign.com - Web: www.templemandesign.com

The ventilation system shall be interlocked with the gas supply to the gas fired catering appliances via current monitoring devices on the supply and extract fans and via a gas safety control system. If the ventilation is not running then the gas solenoid valve is shut preventing the supply of gas to the appliances.

The fire alarm panel is interfaced with the gas safety panel via the BMS (to be replaces under separate project DIO Project number MSET L6098).

m) Fire Dampers

This project does not include works relating to fire dampers.

n) Roof Void

There are no roof voids within the building only ceiling voids. The detection system was replaced in July 2011 by Global Fire and our brief is to exclude replacement of the alarm system.

o) Other Issues

As the client has not provided a fire risk assessment for the existing building which is required in accordance with the Regulatory Reform (Fire Safety) Order 2005, this strategy has been produced to the best of our knowledge & by virtue of this strategy being formally submitted, the client is deemed to have accepted any assumptions & design decisions that have been made.

Form DE USF 131 (12/00) Defence Infrastructure Organisation

CERTIFICATE OF SATISFACTORY STATE OF THE WORKS ON EXPIRATION OF THE

MAINTENANCE PERIOD, (OR COMPLETED PART THEREOF)

Project Manager's Address Bldg 1156, RAF Lakenheath Brandon, Suffolk

IP27 9PP

Tel. No.01638 52 5530 E-mail Address: edward.poloka@lakenheath.af.mil .

Contract Number CT / I N T 2 2 / 1 3 2 1 4

Contractor: Volkerfitzpatrick Ltd

USF Base: RAF Lakenheath .................. Building: ALPHA & BRAVO Apron

Project No.: MSET09-2026 / P2P Order 1704579 / VFL C11977

Nature of works: Repair A and B Bubbles

General short title as shown in Tender Invitation

*The work to which this certificate refers as shown on related form

Completely remove existing concrete bubbles and all associated equipment and re-construct a new aircraft parking ramp complete with all services, to include airfield lighting, high mast lighting, drainage, required lines, landscape area around and restore areas disturbed

Current Contract Completion Date: 29 Jun 2016

The Maintenance Period having expired, I hereby certify that the work referred to above is in a satisfactory state.

Name:………….................... Signature..................................... Date Project Manager Note:

* For use when possession was taken of any part of the Works which were either (a) a section specified in the Abstract of Particulars or (b) a part of the Works, (including a part of a section), in respect of which the parties have agreed, or the PM has given an instruction, that possession shall be given before the completion of the Works.

Distribution: Contractor, Maintenance Manual, Project File, Contracts Branch DIO USF.

Form DIO Ops Accommodation USF 139 (01/10)

CERTIFICATE OF FACILITY ACCEPTANCE – BASE PROJECT

Details of the Project:

USF Project No. MSET09-2026A/B Title: Repair A & B Bubbles

Scope of Work: Remove existing Bubbles and replace with new 10-aircraft parking ramp

Establishment: RAF Lakenheath Building/Facility No: ALPHA & BRAVO Aprons

DIO reference No: P2P 1704579 IP Project Number: C11977

An Acceptance Meeting on 20 Jun 2016 was arranged to consider the handover of completed works as above.

I confirm, on behalf of the IP (VolkerFitzpatrick) that the work is complete (except as agreed on attached deficiency list) and ready for Handover and that the Facility Management Manual and Building Log Book are complete and issued. The IP has responsibility for warranty / defects liability until the dates indicated:

Civil Works 19 Jun 2017

M&E Works 19 Jun 2017

Landscaping N/A

Roofing N/A

Other N/A

Name: (IP) Brian Donovan Signature: Date: 20 Jun 16

Reports from advisers/representatives concerning the works have been reviewed and accepted

• The facility is functional, maintainable and in a safe condition.

• A defects list with a programme of rectification is attached.

DIO PM Name: Ed Poloka Signature: Date: 20 Jun 16

The above equipment has been inspected and does fulfil the scope of work as defined above, subject to satisfactory completion of the outstanding items on the attached deficiency list. Maintenance requirements have been incorporated into the Maintenance Plan, the facility is therefore recommended for acceptance by USF.

US PM Name: Jason Flatt Signature: Date: 20 Jun 16

This certifies that the facility detailed above has been accepted on behalf of the US Forces

Name: David Ryan Signature: Date: 20 Jun 16

BCE or representative:

Exceeds requirement

Does not meet requirement

Nearly meets requirement

Adequately meets requirement

Fully meets requirement

At handover the Customer Representative, the IP, DIO and USF PMs are to assess how well the finished work meets the Requirement as defined in the brief. The agreed level is to be used in Management Reporting.

* delete as appropriate

Distribution: Contractor, Maintenance Manual, Project File, Contracts Branch DE USF.

Form DE USF 130 (12/00)

CERTIFICATE OF COMPLETION OF THE WORKS

Project Manager's Address Bldg 1156, RAF Lakenheath Brandon, Suffolk

IP27 9PP

Tel. No.: 01638 525530 E-mail Address: edward.poloka@lakenheath.af.mil

Contract Number CT / I N T 2 2 / 1 3 2 1 4

Contractor: VolkerFitzpatrick (UK) Ltd

USF Base: RAF Lakenheath ................... Buildings: ALPHA & BRAVO Aprons

Project No.: MSET09-2026 / P2P Order 1704579 / VFL C11977

Nature of works: Remove ALPHA and BRAVO Bubbles and replace with 10-airplane parking ramp.

General short title as shown in Tender Invitation

*The work to which this certificate refers as shown on related form

Completely remove existing concrete bubbles and all associated equipment and re-construct a new aircraft parking ramp complete with all services, to include airfield lighting, high mast lighting, drainage, required lines, landscape area around and restore areas disturbed

Current Contract Completion Date is: 29 June 2016

I hereby certify that the Works required by the above-named Contract were completed to my satisfaction (except as noted on the attached schedule), on 20 Jun 16

The completion dates for the Maintenance Period will be as follows:-

1. Civil work: 19 Jun 2017............................. 2. M&E 19 Jun 2017

Name: Ed Poloka....................... Signature....................................... Date: 20 Jun 16 Project Manager

SCHEDULE OF MAINTAINABLE ASSETS

Item Area Served Electrical Rating Quantity Asset Description Item Manufacturer Model Number Serial Number Date Location / Room Quantity Asset Code

1 NER 28w 8 Type A1/E Luminaires 1 Cooper Crompack N/A Feb-14 NER 8 63100

2 Plant Rooms & External Corridor 54w 11 Type A2 & A2/E Luminaires 2 Cooper Tufflite N/A Feb-14 Plant Rooms & External Corridor 11 63100 3 Refreshment 42w 1 Type B1/E Luminaire 3 Cooper Modulay N/A Feb-14 Refreshment 1 63100 4 ECC & BDOC 54w 17 Type B2/E Luminaires 4 Cooper Modulay N/A Feb-14 ECC & BDOC 17 63100 5 SIPR 72w 1 Type B3/E Luminaire 5 Cooper Modulay N/A Feb-14 SIPR 1 63100 6 Interview 56w 2 Type B4/E Luminaires 6 Cooper Modulay N/A Feb-14 Interview 2 63100 7 Secure Corridor 52w 4 Type C1/E Luminaires 7 Cooper Solstar N/A Feb-14 Secure Corridor 4 63100 8 Entrance Lobby 52w 8 Type C2/E Luminaires 8 Cooper Solstar N/A Feb-14 Entrance Lobby 8 63100 9 Latrine 13w 6 Type C3/E Luminaires 9 Cooper Solstar N/A Feb-14 Latrine 6 63100

10 W.C & Cleaners 18w 4 Type C4/E Luminaires 10 Cooper Solstar N/A Feb-14 W.C & Cleaners 4 63100 11 External 11w 17 Type D Luminaires 11 Thorlux Realta N/A Feb-14 External 17 63100 12 Holding Cell 28w 2 Type F & F/E Luminaires 12 Whitecroft Horizon N/A Feb-14 Holding Cell 2 63100 13 Generally 1w 5 Type G Luminaires 13 Cooper Legpndlite N/A Feb-14 Generally 5 63840 14 Electrical Plant Room 1 Stand-by Generator Set 14 Catipiler OLY00000CLEH00860 GEP150-4 Feb-14 Electrical Plant Room 1 96750 15 Electrical Plant Room 1 UPS System 15 Socomec 131003794520001 Feb-14 Electrical Plant Room 1 62130 16 Electrical Plant Room 1 Main Switchboard MSB 16 Schnieder Powerpact 4 N/A Feb-14 Electrical Plant Room 1 61000 17 Electrical Plant Room 1 Sub-Main Switchboard EMSB 17 Schnieder Powerpact 4 N/A Feb-14 Electrical Plant Room 1 61000 18 Electrical Plant Room 1 Distribution Board EL 18 Schnieder ACTi9 ISOBAR N/A Feb-14 Electrical Plant Room 1 61430 19 NER 1 Distribution Board NER 19 Schnieder ACTi9 ISOBAR N/A Feb-14 NER 1 61430 20 NER 1 Distribution Board NER/A 20 Schnieder 21 NER 1 9kW 230/120v Transformer REMOVED 21 OMITTED 22 Existing Plantroom 120W 1 Electric Tubular Heater 22 Dimplex T120W N/A Feb-14 Existing Plantroom 1 6500 23 Mechanical Plantroom 3.0kW 1 Electric Fan Heater 23 Dimplex PFH30R N/A Feb-14 Mechanical Plantroom 1 6500 24 Electrical Plantroom 3.0kW Each 2 Electric Fan Heater 24 Dimplex PFH30R N/A Feb-14 Electrical Plantroom 2 6500 25 ECC 8 Services floor boxes 25 Schnieder IMF54070 N/A Feb-14 ECC 8 6500 26 Entrance Lobby 1 Fire Alarm Panel 26 ADT 557.200.503 00175-D Feb-14 Entrance Lobby 1 68505 27 Entrance Lobby 1 Monaco Fire Alarm Tranciever 27 Monaco Existing N/A Feb-14 Entrance Lobby 1 68505 28 Generally 5 Fire alarm break glass contacts 28 ADT 514.800.603.A N/A Feb-14 Generally 5 68505 29 Generally 10 Smoke Detectors 29 ADT 850 Series N/A Feb-14 Generally 10 68505 30 Generally 9 Remote Indicators for Smoke detectors 30 Bentel Security 801RIL N/A Feb-14 Generally 9 68505 31 Generally 12 Wall Mounted Fire Alarm Sounder/Beacons 31 Vimpex 958CHX1101 N/A Feb-14 Generally 12 68505 32 Cleaners 1 Ceilng mounted fire alarm beacon 32 33 Mechanical Plantroom 2 Fire Alarm Addressable Input/Output Board 33 ADT 557.202.006 N/A Feb-14 Mechanical Plantroom 2 68505 34 Electrical Plantroom 1 Fire Alarm Addressable Quad Interface 34 ADT 557.201.410 N/A Feb-14 Electrical Plantroom 1 68505 35 DDA - W.C 1 DDA Alarm System 35 Newlec NLEAA N/A Feb-14 DDA - W.C 1 68505 36 Entrance Lobby 1 Teller Draw Intercom System 36 37 Entrance Lobby 1 Door Entry System 37 BPT VRVKX/1 N/A Feb-14 Entrance Lobby 1 64312 38 Secure Corridor 1 Door Entry System 38 BPT EVKITYVCL0VRK N/A Feb-14 Secure Corridor 1 64312 39 Generally 7 CCTV Camera's 39 Samsung SCD-3080 N/A Feb-14 Generally 7 64800 40 Generally 1 Lightning Protection System 40 Nimbus 5000KG N/A Feb-14 Generally 1 69500 41 Main Building Ventilation 2.5kW 1 AHU/01 main air handling unit 41 VES MAX18/A/SP/S SN-AHU01-1064 Feb-14 Main Building Ventilation 1 57212 42 Toilet Areas Ventilation 500W 1 AHU/02 toilet air handling unit 42 VES EVX143-1/FP SN-AHU02-1064 Feb-14 Toilet Areas Ventilation 1 57212 43 Building Ventilation 17 Fusible Link Fire Dampers with Remote LED's 43 Gilberts Fusible Link Type N/A Feb-14 Building Ventilation 17 6500 44 Building Ventilation Heating 3 LTHW heating coils 44 SPC Coils 12WH8.2-13Tx600 N/A Feb-14 Building Ventilation Heating 3 45 Building LTHW 200W Each 2 Heating circulation pumps 45 Grundfos MANGA 25-60 10004760 & 1000A775 Feb-14 Building LTHW 2 46 ECC and BDOC 2 DX coils 46 SPC Coils 12DCH12.3-11Tx450 N/A Feb-14 ECC and BDOC 2 47 ECC and BDOC 2 Control interface to DX coils 47 Mitsubishi Elec PAC-IF012B-E N/A Feb-14 ECC and BDOC 2 48 ECC Room 1 Outdoor condensing unit 48 Mitsubishi Elec PUHZ-RP100VHA N/A Feb-14 ECC Room 1 49 BDOC Room 1 Outdoor condensing unit 49 Mitsubishi Elec PUHZ-RP71VHA 3XU06338 Feb-14 BDOC Room 1

50 NER room 1.25kW Each 3

Ceiling mounted indoor VRF units 50 Mitsubishi Elec PEFY-P250VMH-E 3XW02141, 3XW02140, 3XW02154

Feb-14 NER room 3

51 NER room 24.7kW 1 Outdoor condensing unit 51 Mitsubishi Elec PUHY-P750YSJM-A N/A Feb-14 NER room 1 52 NER room 200W 1 Condensate lifting pump 52 Aspen Mini Blanc - Basic N/A Feb-14 NER room 1 53 Whole Building 1.15kW 1 BMS power and control panel 53 ECS Controls 16161 N/A Feb-14 Whole Building 1 67000 54 Ventilation system 1 Chemical threat shut-down button 54 Schnieder XALK194H7 N/A Feb-14 Ventilation system 1 55 Whole Building 1 Firemans override switch 55 Knox Box series 4500 - model 4544 N/A Apr-14 Whole Building 1 68505 56 Electrical Plant Room 1 6000litre diesel fuel storage tank 56 Cooper & Zim 9203 N/A Feb-14 Electrical Plant Room 1 61494 57 Diesel Generator 1 Evacuation pump 57 Pedrollo 96241 N/A Feb-14 Diesel Generator 1 56100 58 Electrical Plant Room 1 Fire safety motorised shut‐off valve 58 59 Electrical Plant Room 1 Leak detection panel 59 SGB VLR.. Z-65.25-390 353433 Feb-14 Electrical Plant Room 1 60500 60 Electrical Plant Room 1 Sump float switch 60 61 Main Building 2.2kW Each 2 Electric water heaters 61 Heatrae Sadia Hotflo 10 148794 Feb-14 Main Building 2 62 Main Building 2.2kW 1 Electric water heater 62 Heatrae Sadia Hotflo 15 14885 Feb-14 Main Building 1 63 Cold Water supply 1 Strainer 63 Boss 23010626 N/A Feb-14 Cold Water supply 1 53200 64 Building LTHW System 6 Strainers 64 Boss 33042829 N/A Feb-14 Building LTHW System 6 65 District LTHW System 1 Strainer 65 Boss 33042840 N/A Feb-14 District LTHW System 1 66 1 Honeywell silver series regulating light spot 66 EX-OR M52021 PF N/A Feb-14 All Areas 1 67 1 Honeywell Silver series regulating light spot 67 EX-OR MS2001Dalism N/A Feb-14 Corridor 1 68 1 CCTV Recorder 68 American Dynamics ADHD160100 EP 041223P Feb-14 Comms Room 1 64300 69 1 CCTV Monitor 69 American Dynamics ADLCD19MB 131300000020 Feb-14 Comms Room 1 64800 70 Emergency Bulkhead 70 Newlec NL10604 N/A Mar-14 OutsidePorch 1 63840 71 External unit AC 05 71 Mitsubishi PUHZ-ZRP71VHA 3XU06338 Mar-14 ECC Room 1 57000 72 External unit AC 06 72 Mitsubishi PUHZ-ZRP50VKA 35U02582 Mar-14 BDOC Room 1 57000 73 Cooling Unit AC02 73 Mitsubishi PUHY-P350YJM-A 37W04887 Mar-14 NER Room 1 57101 74 Cooling Unit AC01 74 Mitsubishi PUHY-P400YJM-A 3YW03838 Mar-14 NER Room 1 57101 75 75 Assa Assure DC340A Overhead Cam Action Closer 8340120500A Mar-14 D02,D03,D04,D06,D07,D08,D09,D10,D11,D16 10 76 76 Assa Assure 1498 70mm Modular Mortice Latch 80306162313 Mar-14 D03 Interview Room 1

VinciPrincipal Contractor :

Graham Goldsmith

Vinci

Commercial Project Manager (CPM) :

Planning Supervisor :

Total Floor Area (Sq. ft/m) :

RAF Lakenheath

LAK10-2018

Emergency Control Centre Security

Works Description :

17Number Of Rooms :

DE USF Project Sponsor :

RAF Lakenheath

Security

LAK10-2018

Emergency Control Centre

Base :

Project Number :

Facility Number :

Facility Description :

Facility Purpose :Facility Purpose :

Number Of Rooms : 17

Graham Goldsmith

Base :

Facility Number :

Facility Description :

Project Number :

Total Floor Area (Sq. ft/m) :

Commercial Project Manager (CPM) :

Works Description :

Principal Contractor :

Planning Supervisor :

N/A

(To be completed by Principal Contractor during Construction Stage and submitted to CPM prior to Commissioning Stage)

PART A - DESIGN SCHEDULE PART B - INSTALLATION SCHEDULE

DE USF Project Sponsor :

N/A

N/A

N/A

N/A

(To be completed by CPM and submitted to DE USF Project Sponsor at 100% Design Stage)

Form DE USF 140 (06/06) Defence Estates is an Agency of the MOD Page 1 of 1

SCHEDULE OF MAINTAINABLE ASSETS

Item Area Served Electrical Rating Quantity Asset Description Item Manufacturer Model Number Serial Number Date Location / Room Quantity Asset Code

(To be completed by Principal Contractor during Construction Stage and submitted to CPM prior to Commissioning Stage)

PART A - DESIGN SCHEDULE PART B - INSTALLATION SCHEDULE

(To be completed by CPM and submitted to DE USF Project Sponsor at 100% Design Stage)

77 77 Assa Assure 765 70mm Sash Lock 80307062313 Mar-14 D05,D08,D09,D11,D12,D13,D14 7 78 78 Assa Assure 2788 70mm Modular Deadlock 80312862713 Mar-14 D02, D06 & D15 3 79 79 Assa Assure 9788 70mm Mortice Deadlock 80647212713 Mar-14 D17, D18 & D19 3 80 80 Assa Assure 75 12/24v AC/DC Unmonitored switchable strike body 10402200031 Mar-14 D07 & D10 2 81 81 Assa Assure C5802 SCP Double Cylinder 9EA1341 Base Standard Mar-14 D13 ECC Room 1 82 82 Assa Assure C5801 Cylinder 10256310013 Mar-14 D06,D08,D09,D11 & D14 5 83 83 Assa Assure C5803 Cylinder Step 3 10143330013 Mar-14 D15 Holding Cell 2 84 84 Assa Assure CD3500 Codoor Codelock 10038510019425.37 Mar-14 D08, D09 & D11 3 85 85 Assa Assure 8671 Modular EM N/Latch 70mm 1380305962313 Mar-14 D07 & D10 2 86 86 Assa Assure 8761 Panic Bar 10425200017 Mar-14 D02 & D16 2 87 87 Cell Security Corian Seat Waiting Bench - colour Midnight CSL0544 Mar-14 G08 Holding Cell 1 88 88 Dor-jam Type 1-H Oak Veneer, Chipboard Core Hardwood Lippings 926x2040x54mm Fd60 Mar-14 D03 Interview Room 1 22320 89 89 Dor-jam Type 1-B Oak Veneer, Chipboard Core Hardwood Lippings 816x2040x44mm NFR Mar-14 D04 Male Toilet 1 22320 90 90 Dor-jam Type 1-C Oak Veneer, Chipboard Core Hardwood Lippings 916x2040x44mm NFR Mar-14 D05 Disabled Toilet 1 22320 91 91 Dor-jam Type 1-D Oak Veneer, Chipboard Core Hardwood Lippings 826x2040x54mm Fd60 Mar-14 D06 Cleaners Cupboard 1 22320 92 92 Dor-jam Type 1-E Oak Veneer, Chipboard Core Hardwood Lippings 926x2040x54mm Fd60 Mar-14 D07,D08,D10 & D11 4 22320 93 93 Dor-jam Type 1-A Oak Veneer, Chipboard Core Hardwood Lippings 926x2040x54mm Fd60 Mar-14 D09 NER Room 1 22320 94 94 Dor-jam Type 1-G Oak Veneer, Chipboard Core Hardwood Lippings 826x2040x44mm NFR Mar-14 D12 ECC Toliet Door 1 22320 95 95 Dor-jam Type 1-F Oak Veneer, Chipboard Core Hardwood Lippings 926x2040x54mm Fd60 Mar-14 D13 ECC/BDOC Link Door 1 22320 96 96 Dor-jam Type 1-H Oak Veneer, Chipboard Core Hardwood Lippings 926x2040x44mm NFR Mar-14 D14 SIPR Room 1 22320 97 97 Dor-jam Type 1-J Oak Veneer, Chipboard Core Hardwood Lippings 926x2040x54mm Fd60 Mar-14 D15 Holding Cell 1 22320 98 98 JPJ Installations Kawneer AA601 Blast Enhanced,top hung opening light window ATFP compliant frosted windows 690w x 760h Mar-14 G03 Disabled Toilet 1 99 99 JPJ Installations Kawneer AA601 Blast Enhanced,top hung opening light window ATFP compliant frosted windows 910w x 760h Mar-14 G02 Male Toilet 1

100 100 JPJ Installations Kawneer 350 series non-thermally broken welded construction door system in 451PT Framing system 1084w x 2092h Mar-14 D02 Main Entrance 1 22320 101 101 Allegion Single leaf external door, Zintec finish to colour to BS 08 B 29 TD9001 Mar-14 D16 Restricted Corridor 1 22320 102 102 Allegion Double door external door, Zintec finish to colour BS 08 B 29 GD9000 Mar-14 D17 Plantroom 2 1 22320 103 103 Allegion Double door external door, Zintec finish to colour BS 08 B 29 GD9000 Mar-14 D18 Plantroom 1 1 22320 104 104 Allegion Double door external door, Zintec finish to colour BS 08 B 29 GD9000 Mar-14 D19 Plantroom 1 1 22320 105 Whole Building 68 Sprinkler Heads 105 Victaulic V24 N/A Oct-13 All Areas 68

Form DE USF 140 (06/06) Defence Estates is an Agency of the MOD Page 2 of 2

BS 7671:2018

MODEL FORMS

Usage and Reproduction of IET Forms

Subject to your agreement to the following conditions, you are permitted to, free of charge, photocopy and/or electronically manipulate the forms for use solely in connection with your electrical contracting business.

1 Photocopies or reproductions of blank forms shall not be made for the purpose of resale.

2 The IET logo must not be reproduced nor imposed on any copies.

3 The IET’s agreement to your usage of the forms may not be construed to mean that the forms have been checked by the IET for errors or omissions or that they are suitable for your particular purpose.

4 This permission shall automatically lapse after seven years from the date hereof but may then, subject to written application, be considered for renewal.

5 Nothing in this agreement shall be construed as a waiver of the IET’s right under UK Copyright Law and the international conventions to which the UK is a signatory.

2nd July 2018

APPENDIX 6 (Informative)

MODEL FORMS FOR CERTIFICATION AND REPORTING

Introduction

(i) The Electrical Installation Certificate required by Part 6 should be made out and signed or otherwise authenticated by a skilled person or persons in respect of the design, construction, inspection and testing of the work.

(ii) The Minor Electrical Installation Works Certificate required by Part 6 should be made out and signed or otherwise authenticated by a skilled person in respect of the design, construction, inspection and testing of the minor work.

(iii) The Electrical Installation Condition Report required by Part 6 should be made out and signed or otherwise authenticated by a skilled person or persons in respect of the inspection and testing of an existing installation.

(iv) Skilled persons will, as appropriate to their function under (i) (ii) and (iii) above, have a sound knowledge and experience relevant to the nature of the work undertaken and to the technical standards set down in these Regulations, be fully versed in the inspection and testing procedures contained in these Regulations and employ adequate testing equipment.

(v) Electrical Installation Certificates will indicate the responsibility for design, construction, inspection and testing, whether in relation to new work or further work on an existing installation.

Where the design, construction, inspection and testing are the responsibility of one person a Certificate with a single-signature declaration in the form shown below may replace the multiple signatures section of the model form.

FOR DESIGN, CONSTRUCTION, INSPECTION & TESTING

I being the person responsible for the Design, Construction, Inspection & Testing of the electrical installation (as indicated by my signature below), particulars of which are described above, having exercised reasonable skill and care when carrying out the Design, Construction, Inspection & Testing, hereby CERTIFY that the said work for which I have been responsible is to the best of my knowledge and belief in accordance with BS 7671:2018, amended to .............(date) except for the…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .