Attachment 5 - AF 66.xlsx

XLSX spreadsheet 26 KB Posted

Attached to
Add Paint Blast Booth Federal contract opportunity
Solicitation number
FA301020R0035
Issued by
Department of the Air Force Air Education and Training Command

About this file

This submittal register and solicitation outline requirements for an additions project to a walk-in blast booth building.

The submittal register specifies sixteen required submittals for the project manager and contractor administrator related to cast-in place concrete, precast structural concrete, unit masonry, structural steel, steel decking, miscellaneous metals, carpentry, insulation, roofing, firestopping, sealants, doors, louvers, gypsum board, tile, ceilings, flooring, paints, signage, accessories, lockers, sprinklers, plumbing, HVAC, testing and balancing, ducts, unit equipment, electrical work, lighting, and operations/maintenance manuals. Pricing, response dates, and project completion dates are not provided.

The solicitation seeks proposals for additions to a paint blast booth between $1 million to $5 million as a Service-Disabled Veteran-Owned Small Business set-aside. An organized site visit will be held on August 4th, with face coverings required. No award will be made until funds are available, and the government reserves the right to cancel or amend the solicitation. Proposals are due per Sections L and M, with the Department of the Air Force Air Education and Training Command listed as the agency.

View the file

Other files for this federal contract opportunity

Show all 15

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

AF 66 Sheet 1-16

SUBMITTAL REGISTERProject NumberProject Name
MAHG19-1072ADDITIONS TO WALK-IN BLAST BOOTH BUILDING
TO BE COMPLETED BY PROJECT MANAGERTO BE COMPLETED BY CONTRACT ADMINISTRATOR
ITEM NUMBERITEM OR DESCRIPTION OF ITEM, CONTRACT REFERENCE, TYPE OF SUBMITTALNO. OF COPIES REQUIREDREQUIRED SUBMISSION DATEDATE TO CIVIL ENGINEERINGRETURN SUSPENSE DATEDATE CONTRACTOR NOTIFIEDCONTRACTOR RESUBMITTALFINAL APPROVALREMARKS
CERTIFICATION OF COMPLIANCESHOP DRAWINGSSAMPLESCOLOR SELECTIONMANUFACTURER'S RECOMMENDATIONSMANUFACTURER'S WARRANTYCATALOG DATAOPERATING INSTRUCTIONSDATADOCUMENT \ REPORT

APPROVED DIS-APPROVED

1HazMat Questionnaire335 Days Prior to Start Date
2HazMat MSDS35 Days Prior to Start DateMust be filled out if contractor answers YES to the Hazmat Questionnaire
3Hazmat Reporting Entry Form335 Days Prior to Start DateSubmit Final Quantities
4Hazmat Reporting Entry Form33End of Contract
5Recycling and Landfill Report33End of Contract
6Warranty (Manufacturer's)3End of Contract
71-Year Warranty (Contractor)3End of Contract
Section 033000 - Cast-in Place Concrete1
Concrete Testing3
Section 034500 - Precast (Prestressed) Structural Concrete111113
Section 042000 - Unit Masonry11
Section 051200 - Structural Steel11
Section 052100-Steel Joist Framing111
Section 053000 - Steel Decks1111
Section 055013 - Misc. Metal Fabrication11
Section 061000 - Rough Carpentry1
Section 062000 - Finish Carpentry1111
Section 072116 - Mineral Fiber Blanket Insulation1111
Section 072200 - Roof and Deck Insulation1111
Section 072719.01 - Self-Adhering Air Barriers111
Section 076000 - Flashing and Sheet Metal1111
Section 076115.0020 - Aluminum Standing Seam Roofing1111
Section 078400 - Firestopping1111
Section 079200 - Joint Sealants111
Section 081131 - Steel Doors and Frames1111
Section 083323 - Overhead Coiling Doors1111
Section 087100 - Door Hardware111
Section 089100 - Metal Wall Louvers1111
Section 092200 - Supports for Plaster and Gypsum Board11
Section 092900 - Gypsum Board11
Section 093010 - Ceramic, Quarry and Glass Tiling11111
Section 095100 - Acoustical Ceilings11111
Section 096500 - Resilient Flooring (Floor Base)11111
Section 099000 - Paints and Coatings111
Section 101400.20 - Interior Signage111111
Section 102813 - Toilet Accessories111
Section 104416 - Fire Extinguishers111
Section 105113 - Metal Lockers1111
Section 211313.0020 - Wet Pipe Sprinkler System, Fire Protection11111
Section 220000 - Plumbing, General Purpose1
Section 230000 - Air Supply, Distribution, Ventilation, and Exhaust Systems11111
Section 230593 - Testing, Adjusting and Balancing for HVAC13
Section 230700 - Thermal Insulation for Mechanical Systems11
Section 231125 - Facility Gas Piping111
Section 233113.0040 - Metal Ducts111
Section238100 - Decentralized Unitary HVAC Equipment1111
Section 260500.0040 - Common Work Results for Electrical1
Section 260526.00.40 Grounding and Bonding for Electrical Systems1111
Section 262000 - Interior Distribution System111
Section 264100 - Lightning Protection System1111
Section 265100 - Interior Lighting111
Operation and Maintenance333332 hard copy binders, 1 electronic copy

File details come from the government source that posted it. Updated .