| INVENTORY OF CROSS-CONNECTION CONTROL AND BACKFLOW PREVENTION DEVICES | PROGRAM MANAGER | ||||||||||||||
| OFFUTT AFB | PERSONNEL MAKING INVENTORY: | Al. Nelson 294-7586 / 4836 | |||||||||||||
| CONTROL NO ISSUED | LOCATION | ITEM / FACILITY SYSTEM PROTECTED | POTENTIAL CONTAINMNT/POLLUTENT | DEGREE OF HAZARD / DEVICE SERIAL NUMBER | BACK PRESS POTENT | BACK SIPHONAGE POTENTIAL | TYPE CONTROL INSTALLED OR (REQUIRED) | DATA ON DEVICE INSTAL | COMMENTS | COMP | TOT | NXT YR. | TYPE # | ||
| MAKE | MODEL | SIZE | |||||||||||||
| 1 TEST | 500 BLDG BOILER RM | H.W. MAKEUP TO 750 TON RACK | CHEMICALS | 128893/HIGH | YES | YES | R.P.B.P. | WATTS | 909 | 3/4" | DEVICE DELETED, NO LONGER NEEDED 7/19/04 NELSON | 0 | 0 | ||
| 6 TEST | BLDG. 500 BOILER ROOM | GROSS. MAKE UP TO WATER SOFT / BOILER | CHEMICAL | CY112/HIGH | YES | YES | R.P.B.P. | CONBRACO | 40207A2 | 11/2" | Device transferred to 500 Maint | 0 | 0 | 51/001 | |
| 5TEST | 0 | 0 | |||||||||||||
| 7 TEST | 500 BLDG BOILER RM | MAKEUP TO CHILLED H2O SYSTEM | CHEMICALS | 89971 /HIGH | YES | YES | R.P.B.P. | WATTS | 009-M1 | 2" | Device transferred to 500 Maint | 0 | 0 | 50/004 | |
| 11 TEST | BLDG 500BH 30 MECH RM | MAKEUP FOR REHEAT SYS, H-WING | CHEMICALS | 89814/HIGH | YES | YES | R.P.B.P. | WATTS | OO9 | 3/4" | Device Removed | 0 | 0 | 7/21/07 | 50/005 |
| 12 TEST | 500 BLDG BJ WING-MECH RM | MAKE-UP FOR BOILERS | CHEMICALS | 568620/HIGH | YES | YES | R.P.B.P. | WATTS | 909 | 3/4" | Device transferred to 500 Maint | 0 | 0 | 50/006 | |
| 13 TEST | 500 BLDG 3J MECH RM | MAKEUP FOR REHEAT SYSTEM | CHEMICALS | 116207/HIGH | YES | YES | R.P.B.P. | WATTS | 909 | 1" | Device transferred to 500 Maint | 0 | 0 | 50/007 | |
| 14 TEST | BLDG 500 KITCHEN | C.W. TO COOKING HOOD SYSTEM | GREASE / CHEMICALS | 34080 / HIGH | YES | YES | R.P.B.P. | WATTS | OO9 | 1 1/4" | Device transferred to 500 Maint | 0 | 0 | 50/376 | |
| 15 TEST | BLDG 500 RM 1E11 | C.W. SUPPLY TO CHEMICAL DISPENSER | SOAP CHEMICALS | A21613 / HIGH | YES | YES | R.P.B.P. | WATTS | OO9 | 1/2" | Device transferred to 500 Maint | 0 | 0 | 50/001 | |
| 16 TEST | BLDG 500 KITCHEN | POP DISPENSERS | CARBONATION, SYRUP | 55124/LOW | YES | YES | R.P.B.P. | WATTS | 009M2 | 1/2" | Device transferred to 500 Maint | 0 | 0 | 50/008 | |
| 17 FP | BLDG 500 THEATER MECH RM | FIRE PROTECT SYSTEM THEATER | RUST STAGNANT WATER | LOW | YES | YES | SINGLE CHECK VALVE | VIKING | C421-2 | 4" | 0 | 0 | |||
| INVENTORY OF CROSS-CONNECTION CONTROL AND BACKFLOW PREVENTION DEVICES | |||||||||||||||
| OFFUTT AFB | PERSONNEL MAKING INVENTORY: | ||||||||||||||
| CONTROL NO ISSUED | LOCATION | ITEM / FACILITY SYSTEM PROTECTED | POTENTIAL CONTAINMENT/POLLUTANT | DEGREE OF HAZARD / DEVICE SERIAL NUMBER | BACK PRESS POTENT | BACK SIPHONAGE POTENTIAL | TYPE CONTROL INSTALLED OR (REQUIRED) | DATA ON DEVICE INSTAL | COMMENTS | COMP | TOT | NXT YR. | TYPE # | ||
| MAKE | MODEL | SIZE | |||||||||||||
| 18 VB | BLDG 500 H WING | 11 HOSE BIBBS, 8 SERVICE SINKS, 12 WALL HYDRANTS | CHEMICALS / SEWAGE | HIGH | NO | YES | SCREW ON VACUUM BREAKER | WATTS | 8A | 5/8" | 0 | 0 | |||
| 19 VB | BLDG 500 JWING | 4 HOSE BIBS, 4 SERVICE SINKS | CHEMICALS / SEWAGE | HIGH | NO | YES | SCREW ON VACUUM BREAKER | WATTS | 8A | 5/8" | 0 | 0 | |||
| 20 VB | BLDG 500 D WING | 2 SERVICE SINKS | CHEMICALS / SEWAGE | HIGH | NO | YES | SCREW ON VACUUM BREAKER | WATTS | 8A | 5/8" | 0 | 0 | |||
| 21 VB | BLDG 500 G WING | 4 HOSE BIBS, 4 SERVICE SINKS, 4 WALL HYDR. | CHEMICALS / SEWAGE | HIGH | NO | YES | SCREW ON VACUUM BREAKER | WATTS | 8A | 5/8" | 0 | 0 | |||
| 22 VB | BLDG 500 A WING | 6 HOSE BIBBS | CHEMICALS / SEWAGE | HIGH | NO | YES | SCREW ON VACUUM BREAKER | WATTS | 8A | 5/8" | 0 | 0 | |||
| 23 VB | BLDG 500 F WING | 6 HOSE BIBBS, 4 SERVICE SINKS | CHEMICALS / SEWAGE | HIGH | NO | YES | SCREW ON VACUUM BREAKER | WATTS | 8A | 5/8" | 0 | 0 | |||
| 24 VB | BLDG 500 B WING | 7 HOSE BIBBS, 4 SERVICE SINKS | CHEMICALS / SEWAGE | HIGH | NO | YES | SCREW ON VACUUM BREAKER | WATTS | 8A | 5/8" | 0 | 0 | |||
| 25 VB | BLDG 500 BOILER RM | 27 HOSE BIBBS | CHEMICALS / SEWAGE | HIGH | NO | YES | SCREW ON VACUUM BREAKER | WATTS | 8A | 5/8" | ALL EQUIPMENT DRAINS SHOULD BE LABELED AS NON-POTABLE WATER | 0 | 0 | ||
| 26 TEST | BLDG 515 MECH RM | C.W. MAKEUP TO REHEAT SYSTEM | CHEMICALS | HIGH / 115925 | YES | YES | R.P.B.P. | WATTS | 909 | 3/4" | Device transferred to 500 Maint | 0 | 0 | 50/009 | |
| 27 FP | BLDG 515 MECH RM | FIRE PROTECT SYSTEM | RUST STAGNANT WATER | LOW | YES | YES | SINGLE CHECK VALVE | RELIABLE | DG | 4" | 0 | 0 | |||
| INVENTORY OF CROSS-CONNECTION CONTROL AND BACKFLOW PREVENTION DEVICES | |||||||||||||||
| OFFUTT AFB | PERSONNEL MAKING INVENTORY: | ||||||||||||||
| CONTROL NO ISSUED | LOCATION | ITEM / FACILITY SYSTEM PROTECTED | POTENTIAL CONTAINMENT/POLLUTANT | DEGREE OF HAZARD / DEVICE SERIAL NUMBER | BACK PRESS POTENT | BACK SIPHONAGE POTENTIAL | TYPE CONTROL INSTALLED OR (REQUIRED) | DATA ON DEVICE INSTAL | COMMENTS | COMP | TOT | NXT YR. | TYPE # | ||
| MAKE | MODEL | SIZE | |||||||||||||
| 28 FP | BLDG 515 MECH RM | FIRE PROTECT SYSTEM | RUST STAGNANT WATER | LOW | YES | YES | SINGLE CHECK VALVE | RELIABLE | DG | 4" | 0 | 0 | |||
| 29 FP | BLDG 515 MECH RM | FIRE PROTECT SYSTEM | RUST STAGNANT WATER | LOW | YES | YES | SINGLE CHECK VALVE | RELIABLE | DG | 6" | 0 | 0 | |||
| 30 FP | BLDG 578 MECH RM | FIRE PROTECT SYSTEM | RUST STAGNANT WATER | LOW/ FO312041310 | YES | YES | DCV | FEBCO | 850 | 6" | TESTED DEVICE 6/26/13 Alves | 1 | 0 | 0/26/2014 | 56/031 |
| 31 TEST | BLDG 597 A 107 | C.W. MAKEUP TO REHEAT SYSTEM | CHEMICALS | 237479 / HIGH | YES | YES | R.P.B.P. | WATTS | 909 | 3/4" | TESTED DEVICE | 0 | 1 | 50/023 | |
| 32 TEST | BLDG 597 A 107 | C.W. MAKEUP LIEBERT UNITS | CHEMICALS | 155022 / HIGH | YES | YES | R.P.B.P. | WATTS | 909 | 1" | TESTED DEVICE | 0 | 1 | 50/024 | |
| 33 FP | BLDG 597 A 213 | FIRE PROTECT SYSTEM | RUST STAGNANT WATER | LOW | YES | YES | SINGLE CHECK VALVE | 4" | 0 | 1 | |||||
| 34 EXIST | BLDG 597 | 3 HOSE BIBBS 1 SERVICE SINK | CHEMICALS / SEWAGE | HIGH | NO | YES | SCREW ON VACUUM BREAKER | WATTS | 8A | 5/8" | 0 | 1 | |||
| 35 TEST | BLDG 509 NO SIDE A WING | LAWN SPRINKLER SYS | LAWN CHEMICALS | 156834 / HIGH | NO | YES | R.P.B.P. | WATTS | 909 | 11/2" | DEVICE HAS BEEN REMOVED ACCORDING TO BLDG PLUMBER 5/12/99 | 0 | 1 | ||
| 36 TEST | BLDG 500 FRONT LAWN | LAWN SPRINKLER SYS | LAWN CHEMICALS | 156834 / HIGH | NO | YES | R.P.B.P. | WATTS | 909 | 3" | TESTED DEVICE | 0 | 1 | 50/018 | |
| 37 TEST | BLDG 500 S SIDE A WING | LAWN SPRINKLER SYS | LAWN CHEMICALS | HIGH | NO | YES | R.P.B.P. | WATTS | 909 | 11/2" | DEVICE HAS BEEN REMOVED ACCORDING TO BLDG PLUMBER 5/12/99 | 0 | 1 | ||
| INVENTORY OF CROSS-CONNECTION CONTROL AND BACKFLOW PREVENTION DEVICES | |||||||||||||||
| OFFUTT AFB | PERSONNEL MAKING INVENTORY: | ||||||||||||||
| CONTROL NO ISSUED | LOCATION | ITEM / FACILITY SYSTEM PROTECTED | POTENTIAL CONTAINMENT/POLLUTANT | DEGREE OF HAZARD / DEVICE SERIAL NUMBER | BACK PRESS POTENT | BACK SIPHONAGE POTENTIAL | TYPE CONTROL INSTALLED OR (REQUIRED) | DATA ON DEVICE INSTAL | COMMENTS | COMP | TOT | NXT YR. | TYPE # | ||
| MAKE | MODEL | SIZE | |||||||||||||
| 38 TEST | BLDG. 5O1 U144 | OIL COOLER MAKEUP | CHEMICALS, OIL, FREON | HIGH | YES | YES | R.P.B.P. | WATTS | OO9 | 1/2" | DEVICE REMOVED ACCORDING TO BLDG. PLBR NELSON 7/20/99 | 0 | 1 | ||
| 39 TEST | BLDG 501 U 144 | C.W. MAKEUP TO REHEAT SYSTEM | CHEMICALS | 89800 / HIGH | YES | YES | R.P.B.P. | WATTS | 909 | 3/4" | DEVICE DELETED, NO LONGER NEEDED 4/5/05 NELSON | 0 | 1 | 50/011 | |
| 40 TEST | BLDG 501 L 138 | C.W. MAKEUP TO ABANDONED CHILLER | CHEMICALS / STAGNANT WATER | HIGH | YES | YES | R.P.B.P. | WATTS | OO9 | 3/4" | DEVICE HAS BEEN REMOVED ACCORDING TO BLDG. PLUMBER NELSON / LEWIS 7/20/99 | 0 | 1 | ||
| 41 TEST | BLDG 501 L 112A | C.W. MAKEUP TO REHEAT SYSTEM | CHEMICALS | HIGH / A05932 | YES | YES | R.P.B.P. | WATTS | OO9 | 1" | TESTED DEVICE | 0 | 1 | 56/001 | |
| 42 FP | BLDG 501 V 145 | FIRE PROTECTION SYSTEM | RUST STAGNANT WATER | LOW / 00139 | YES | YES | D.C.V. | WATTS | 770 | 6" | TESTED DEVICE | 0 | 1 | 50/012 | |
| 43 TEST | BLDG 501 U 145 | C.W. MAKE-UP TO REHEAT SYSTEM | CHEMICALS | 12702 / HIGH | YES | YES | R.P.B.P. | WATTS | 909 | 3/4" | TEST DEVICE | 0 | 1 | 50/013 | |
| 45 TEST | BLDG 501 U 145 | C.W. MAKE-UP TO AIR HANDLER | CHEMICALS WELL WATER | 14496 / HIGH | YES | YES | R.P.B.P. | WATTS | 909 | 1 1/2" | TESTED DEVICE | 0 | 1 | 50/014 | |
| 46 TEST | BLDG 501 U 145 | C.W. MAKE-UP GLYCOL TANK | GLYCOL | A09974 / HIGH | YES | YES | R.P.B.P. | WATTS | OO9 | 1/2" | TESTED DEVICE | 0 | 1 | 50/015 | |
| 47 TEST | BLDG 501 U 145 | C.W. MAKE-UP TO DIESEL JACKET WATER | CHEMICALS | O5723 / HIGH | YES | YES | R.P.B.P. | WATTS | OO9 | 1 1/4" | TESTED DEVICE | 0 | 1 | 50/016 | |
| 48 TEST | BLDG 501 | 12 HOSE BIBBS 4 SERVICE SINKS | CHEMICALS SEWAGE | HIGH | NO | YES | SCREW ON VACUUM BREAKER | WATTS | 8A | 5/8" | 0 | 1 | |||
| 49 TEST | BLDG 500 1 G HALLWAY | C.W. MAKE-UP TO HOT WATER | CHEMICALS | Unknown/ HIGH | YES | YES | R.P.B.P. | WATTS | 909 | 3/4" | TESTED DEVICE | 0 | 1 | 50/017 | |
| 50 FP | BLDG 522 MECH RM | FIRE PROTECTION SYSTEM | RUST STAGNANT WATER | LOW | YES | YES | S.C.V. | RELIABLE | 4" | 0 | 1 | ||||
| INVENTORY OF CROSS-CONNECTION CONTROL AND BACKFLOW PREVENTION DEVICES | |||||||||||||||
| OFFUTT AFB | PERSONNEL MAKING INVENTORY: | ||||||||||||||
| CONTROL NO ISSUED | LOCATION | ITEM / FACILITY SYSTEM PROTECTED | POTENTIAL CONTAINMENT/POLLUTANT | DEGREE OF HAZARD / DEVICE SERIAL NUMBER | BACK PRESS POTENT | BACK SIPHONAGE POTENTIAL | TYPE CONTROL INSTALLED OR (REQUIRED) | DATA ON DEVICE INSTAL | COMMENTS | COMP | TOT | NXT YR. | TYPE # | ||
| MAKE | MODEL | SIZE | |||||||||||||
| 51 TEST | BLDG 407 MECH RM 12 | C.W. MAKE-UP TO REHEAT SYSTEM | CHEMICALS | 128447 / HIGH | YES | YES | R.P.B.P. | WATTS | 909 | 3/4" | TESTED DEVICE | 0 | 1 | 50/018 | |
| 52 TEST | BLDG 407 | 2 HOSE BIBBS, 5 WALL HYD, 1 SERVICE SINK | CHEMICALS SEWAGE | HIGH | NO | YES | SCREW ON VACUUM BREAKER | WATTS | 8A | 5/8" | 0 | 1 | |||
| 53 TEST | BLDG 513 MECH RM | C.W. MAKE-UP TO BOILER & VACUUM PUMP | CHEMICALS & SALIVA | HIGH / 137326 | YES | YES | R.P.B.P. | WATTS | OO9 | 3/4" | TESTED DEVICE | 0 | 1 | 50/019 | |
| 54 TEST | BLDG 513 | 2 HOSE BIBBS, 2 WALL HYD, 1 SERVICE SINK | CHEMICALS SEWAGE | HIGH | NO | YES | SCREW ON VACUUM BREAKER | WATTS | 8A | 5/8" | 0 | 1 | |||
| 55 TEST | BLDG 519 CELL 5 | C.W. MAKE-UP TO COOLING TOWER | CHEMICALS / LEGIONAIRES DISEASE | HIGH | YES | YES | R.P.B.P. | WATTS | OO9 | 3" | DEVICE HAS BEEN REMOVED AND PIPED FROM CELL 1 | 0 | 1 | ||
| 56 TEST | BLDG 519 CELL 1 | C.W. MAKE-UP TO COOLING TOWER | CHEMICALS / LEGIONAIRES DISEASE | 27715 / HIGH | YES | YES | R.P.B.P. | WATTS | OO9 | 3" | TESTED DEVICE | 0 | 1 | 50/020 | |
| 57 TEST | BLDG 519 CELL 1 | C.W. MAKE-UP TO COOLING TOWER | CHEMICALS / LEGIONAIRES DISEASE | 02785 / HIGH | YES | YES | R.P.B.P. | WATTS | OO9 | 3" | TESTED DEVICE | 0 | 1 | 50/021 | |
| 58 TEST | BLDG 518 | FIRE PROTECTION SYSTEM | RUST STAGNANT WATER | HIGH / 2CL0889 | YES | YES | R.P.B.P. | AMES | 2000SS | 6" | TESTED DEVICE | 0 | 1 | 58/01 | |
| 60 TEST | BLDG 518 | GENERATOR JACKET WATER BOILER MAKEUP | OIL GLYCOL CHEMICALS | HIGH / 122185 | YES | YES | R.P.B.P. | WATTS | 909 | 1 1/2" | TESTED DEVICE | 0 | 1 | 50/022 | |
| 61 EXIST | BLDG 591 | 2 HOSE BIBBS 2 WALL HYDRANTS | CHEMICALS SEWAGE | HIGH | NO | YES | SCREW ON VACUUM BREAKER | WATTS | 8A | 5/8" | 0 | 1 | |||
| 62 TEST | BLDG 4000 BOILER RM | C.W. MAKE-UP TO BOILER | CHEMICALS | 127796 / HIGH | YES | YES | R.P.B.P. | WATTS | 909 | 1 1/4" | DEVICE IS REMOVED 8/26/06 ROBLES | 0 | 1 | 50/036 | |
| 63 FP | BLDG 4000 BOILER RM | FIRE PROTECTION SYSTEM | RUST STAGNANT WATER | 9601261251 / LOW | YES | YES | D.C.V. | FEBCO | 850 DC | 6" | Hospital Maintenence | 1 | 9/28/10 | 56/03 | |
| INVENTORY OF CROSS-CONNECTION CONTROL AND BACKFLOW PREVENTION DEVICES | |||||||||||||||
| OFFUTT AFB | PERSONNEL MAKING INVENTORY: | ||||||||||||||
| CONTROL NO ISSUED | LOCATION | ITEM / FACILITY SYSTEM PROTECTED | POTENTIAL CONTAINMENT/POLLUTANT | DEGREE OF HAZARD / DEVICE SERIAL NUMBER | BACK PRESS POTENT | BACK SIPHONAGE POTENTIAL | TYPE CONTROL INSTALLED OR (REQUIRED) | DATA ON DEVICE INSTAL | COMMENTS | COMP | TOT | NXT YR. | TYPE # | ||
| MAKE | MODEL | SIZE | |||||||||||||
| 64 TEST | BLDG 4000 BOILER RM | C.W. MAKE-UP TO BOILER & CHILLER | CHEMICALS | 477504 / HIGH | YES | YES | R.P.B.P. | WATTS | 909 | 3/4" | Hospital Maintenence | 1 | 9/17/10 | 50/037 | |
| 65 TEST | BLDG 4000 BOILER RM | COLD WATER SUPPLY TO BOILER | CHEMICALS | SH782 / HIGH | YES | YES | R.P.B.P. | CONBRACO | 40205T2 | 1" | Hospital Maintenence | 1 | 9/10/10 | 51/011 | |
| 66 TEST | BLDG 4000 RM GD08 | COLD WATER SUPPLY TO CHEM CLEAN | CHEM / SOAP | A27664 / HIGH | YES | YES | R.P.B.P. | WATTS | OO9 | 1/2" | Hospital Maintenence | 1 | 9/11/10 | 50/036 | |
| 67A TEST | BLDG 4000 Main Entrance | C.W. SUPPLY TO LAWN SPRINKLER | CHEMICAL / FERTILIZERS | HIGH / 197507 | YES | YES | R.P.B.P. | WATTS | OO9M2 | 1" | Hospital Maintenence | 1 | 8/12/10 | 50/038 | |
| 68 TEST | BLDG 4000 BOILER RM | C.W. MAKE-UP TO COOLING TOWER | CHEMICALS/ LEGIONAIRES DISEASE | 89975 / HIGH | YES | YES | R.P.B.P. | WATTS | OO9 | 2" | Hospital Maintenence | 1 | 9/17/10 | 50/039 | |
| 69 TEST | BLDG 4000 BOILER RM | DOMESTIC WATER MAIN | CONTAMINATES FROM HOSPITAL | 25478 /HIGH | YES | YES | R.P.B.P. | WATTS | OO9 | 3" | Hospital Maintenence | 1 | 9/10/10 | 50/040 | |
| 70 TEST | BLDG 4000 BOILER RM | DOMESTIC WATER MAIN BY-PASS | CONTAMINATES FROM HOSPITAL | 06534 /HIGH | YES | YES | R.P.B.P. | WATTS | OO9 | 3" | Hospital Maintenence | 1 | 9/21/10 | 50/041 | |
| 71 TEST | BLDG 4000 KITCHEN | LAUNDRY ROOM BY KITCHEN | HIGH / 247753 | YES | YES | R.P.B.P. | WATTS | OO9 | 1/2" | Hospital Maintenence | 1 | 8/22/10 | 50/042 | ||
| 72 TEST | BLDG 4000 KITCHEN | LAUNDRY ROOM BY KITCHEN | C.W. MAKE UP TO SOAP DISPENSER | HIGH / | YES | YES | R.P.B.P. | WATTS | OO9 | 1/2" | REMOVED FROM INVENTORY. DEVICE NO LONGER EXISTS | 0 | 1 | ||
| 73 TEST | BLDG 4000 JANITOR G105 | CLEANING CHEM MIX STATION | CHEMICALS / SOAP | HIGH / A26777 | YES | YES | R.P.B.P. | WATTS | OO9 | 1/2" | Hospital Maintenence | 1 | 9/11/10 | 50/050 | |
| 74 TEST | BLDG 4000 LAB GB07 | C.W. SUPPLY TO CHEMISTRY ANALYZER | BLOOD TESTER | HIGH / A26791 | YES | YES | R.P.B.P. | WATTS | OO9 | 1/2" | Hospital Maintenence | 1 | 9/11/10 | 50/059 | |
| 75 TEST | BLDG 4000 RADIOLOGY IJ08-A | C.W. MAKE-UP TO X-RAY PROCESSOR | CHEMICALS | / HIGH | YES | YES | R.P.B.P. | WATTS | OO9 | 1/2" | Decice Removed | 0 | 1 | 50/043 | |
| INVENTORY OF CROSS-CONNECTION CONTROL AND BACKFLOW PREVENTION DEVICES | |||||||||||||||
| OFFUTT AFB | PERSONNEL MAKING INVENTORY: | ||||||||||||||
| CONTROL NO ISSUED | LOCATION | ITEM / FACILITY SYSTEM PROTECTED | POTENTIAL CONTAINMENT/POLLUTANT | DEGREE OF HAZARD / DEVICE SERIAL NUMBER | BACK PRESS POTENT | BACK SIPHONAGE POTENTIAL | TYPE CONTROL INSTALLED OR (REQUIRED) | DATA ON DEVICE INSTAL | COMMENTS | COMP | TOT | NXT YR. | TYPE # | ||
| MAKE | MODEL | SIZE | |||||||||||||
| 76 TEST | BLDG 4000 RADIOLOGY 1008-A | C.W. MAKE-UP TO X-RAY PROCESSOR | CHEMICALS | / HIGH | YES | YES | R.P.B.P. | WATTS | OO9 | 1/2" | Device Removed | 0 | 1 | 50/044 | |
| 77 VB | BLDG 4000 RADIOLOGY 1008-A | 2 HOSE BIBBS 1 SERVICE SINK | CHEMICALS SEWAGE | HIGH | NO | YES | SCREW ON VACUUM BREAKER | WATTS | 8A | 5/8" | 0 | 1 | |||
| 78 TEST | BLDG 4000 MAMOGRAPHY 1002-B | C.W. MAKE-UP TO X-RAY PROCESSOR | CHEMICALS | 55126 / HIGH | YES | YES | R.P.B.P. | WATTS | OO9 | 1/2" | Hospital Maintenence | 1 | 8/7/10 | 50/045 | |
| 79 TEST | MAKEUP WATER TO X-RAY PROCESSOR | CHEMICALS | / HIGH | YES | YES | R.P.B.P. | WATTS | OO9QT | 1/2" | Device Removed 9/8/08 Robles/Pyle | 0 | 1 | N/A | 50/046 | |
| 80 TEST | MAKEUP WATER TO X-RAY PROCESSOR | CHEMICALS | / HIGH | YES | YES | R.P.B.P. | WATTS | OO9 | 1/2" | Device Removed 9/8/08 Robles/Pyle | 0 | 1 | N/A | 50/047 | |
| 81 TEST | BLDG 4000 DENTAL LAB | C.W. MAKE-UP TO PERO. AIR COND | FREON OIL | HIGH | YES | YES | R.P.B.P. | WATTS | OO9 | 1/2" | DEVICE IS STILL IN PLACE, BUT AIR CONDITIONING EQUIP HAS BEEN REMOVED. GREG KIEPKE 8/13/99 | 0 | 1 | ||
| 82 TEST | BLDG 4000 S MECH RM | C.W. MAKE-UP TO WATER SOFTENER | SODIUM CHEMICALS | 88414 / HIGH | YES | YES | R.P.B.P. | FEBCO | 825Y | 2" | DEVICE NO LONGER EXISTS DELETE FROM INVENT 6/13/05 | 0 | 1 | 56/04 | |
| 83 VB | BLDG 4000 S MECH RM | 5 HOSE BIBBS 1 SERVICE SINK | CHEMICALS SEWAGE | LOW | NO | YES | SCREW ON VACUUM BREAKER | WATTS | 8A | 5/8" | 0 | 1 | |||
| 84 FP | BLDG 4000 S MECH RM | FIRE PROTECTION SYSTEM | RUST STAGNANT WATER | 9601301340 / LOW | YES | YES | D.C.V. | FEBCO | 850 | 6" | Hospital Maintenence | 1 | 9/28/10 | 56/05 | |
| 85 TEST | BLDG 4000 S MECH RM | C.W. MAKE-UP TO CHILLER | CHEMICALS | 547163 / HIGH | YES | YES | R.P.B.P. | WATTS | 909 | 3/4" | Hospital Maintenence | 1 | 9/10/10 | 50/048 | |
| 86 TEST | BLDG 4000 S MECH RM | C.W. MAKE-UP PERIMETER HTG. | CHEMICALS | 127069 / HIGH | YES | YES | R.P.B.P. | WATTS | 909 | 3/4" | Hospital Maintenence | 1 | 9/10/10 | 50/049 | |
| 87 TEST | BLDG 4000 S MECH RM | C.W. MAKE-UP TO VACUMM RECEIVERS | CHEMICALS WASTE | 147752/ high | YES | YES | R.P.B.P. | WATTS | 909 | 1 1/2" | Hospital Maintenence | 1 | 9/10/10 | ||
| INVENTORY OF CROSS-CONNECTION CONTROL AND BACKFLOW PREVENTION DEVICES | |||||||||||||||
| OFFUTT AFB | PERSONNEL MAKING INVENTORY: | ||||||||||||||
| CONTROL NO ISSUED | LOCATION | ITEM / FACILITY SYSTEM PROTECTED | POTENTIAL CONTAINMENT/POLLUTANT | DEGREE OF HAZARD / DEVICE SERIAL NUMBER | BACK PRESS POTENT | BACK SIPHONAGE POTENTIAL | TYPE CONTROL INSTALLED OR (REQUIRED) | DATA ON DEVICE INSTAL | COMMENTS | COMPLETED | TOTAL | NXT YR. | TYPE # | ||
| MAKE | MODEL | SIZE | |||||||||||||
| 88 TEST | BLDG 4000 | C.W. MAKE-UP TO COOLING TOWER | GLYCOL / RUST | 56161 / HIGH | YES | YES | R.P.B.P. | WATTS | 009M2 | 1/2" | Hospital Maintenence | 1 | 8/10/10 | 50/051 | |
| 89 TEST | BLDG 4000 gi27 | H.W. MAKE-UP TO EMBALMING | CHEMICAL | HIGH / 57213 | YES | YES | R.P.B.P. | WATTS | OO9 | 1/2" | Hospital Maintenence | 1 | 9/22/10 | 50/052 | |
| 90 TEST | BLDG 4209 MECH RM | C.W. MAKE-UP TO CHILLER | CHEMICALS | 386525 / HIGH | YES | YES | R.P.B.P. | WATTS | 909 | 3/4" | TESTED DEVICE | 0 | 1 | 50/053 | |
| 91 TEST | BLDG 4209 MECH RM | C.W. MAKE-UP TO AIR COMPRESSOR | COMPRESSOR OIL | 124967/ HIGH | YES | YES | R.P.B.P. | WATTS | OO9 | 3/4" | TESTED DEVICE | 0 | 1 | 50/054 | |
| 92 VB | BLDG 4209 MECH RM | 1 SERVICE SINK 6 WALL HYD. 4 HOSE BIBBS | CHEMICALS SEWAGE | HIGH | NO | YES | SCREW ON VACUUM BREAKER | WATTS | 8A | 5/8" | 0 | 1 | |||
| 93 FP | BLDG 4209 BOILER RM | FIRE PROTECTION SYSTEM | RUST STAGNANT WATER | NDL96/LOW | YES | YES | D.C.V. | CONBRACO | 4" | TESTED DEVICE | 0 | 1 | 51/012 | ||
| 94 TEST | BLDG 4209 BOILER RM | LAWN IRRIGATION SYSTEM | LAWN CHEMICALS | 06571/HIGH | YES | YES | R.P.B.P. | WATTS | OO9 | 1 1/2" | TESTED DEVICE | 0 | 1 | 50/055 | |
| 95 TEST | BLDG 4209 BOILER RM | C.W. MAKE-UP TO BOILER & CHILLER | CHEMICALS | 89830 / HIGH | YES | YES | R.P.B.P. | WATTS | OO9 | 3/4" | TESTED DEVICE | 0 | 1 | 50/056 | |
| 96 FP | BLDG 3998 | FIRE PROTECTION SYSTEM | RUST STAGNANT WATER | LOW | YES | YES | SINGLE CHECK VALVE | RELIABLE | DG | 4" | No Longer Our Device, Belongs to Contractor | 0 | 1 | 9/13/08 | 53/001 |
| 97 TEST | BLDG 4000 BOILER RM | C.W. MAKE-UP TO DOM. H.W. HEAT EXCH. | CHEMICALS | 88972 / HIGH | YES | YES | R.P.B.P. | WATTS | OO9 | 2" | Hospital Maintenence | 1 | 9/17/10 | 50/057 | |
| 99 TEST | BLDG 4000 gi27 | C.W. MAKE-UP TO EMBALMING | BIOLOGICAL WASTE | 55121 / HIGH | YES | YES | R.P.B.P. | WATTS | OO9 | 1/2" | Hospital Maintenence | 1 | 9/22/10 | 50/057 | |
| 100 TEST | BLDG 4000 KITCHEN | C.W. MAKE-UP TO DOM. H.W. HEAT EXCH. | CHEMICALS | 05713 / HIGH | YES | YES | R.P.B.P. | WATTS | OO9 | 1 1/4" | Hospital Maintenence | 0 | 1 | ||
| INVENTORY OF CROSS-CONNECTION CONTROL AND BACKFLOW PREVENTION DEVICES | |||||||||||||||
| OFFUTT AFB | PERSONNEL MAKING INVENTORY: | ||||||||||||||
| CONTROL NO ISSUED | LOCATION | ITEM / FACILITY SYSTEM PROTECTED | POTENTIAL CONTAINMENT/POLLUTANT | DEGREE OF HAZARD / DEVICE SERIAL NUMBER | BACK PRESS POTENT | BACK SIPHONAGE POTENTIAL | TYPE CONTROL INSTALLED OR (REQUIRED) | DATA ON DEVICE INSTAL | COMMENTS | COMP | TOT | NXT YR. | TYPE # | ||
| MAKE | MODEL | SIZE | |||||||||||||
| 101 TEST | BLDG 457 RM 235 | C.W. MAKE-UP TO LIEBERT UNIT | CHEMICALS | 57203 / HIGH | YES | YES | R.P.B.P. | WATTS | OO9 | 1/2" | TESTED DEVICE | 0 | 1 | 50/060 | |
| 102 FP | BLDG 457 MECH RM 515 | FIRE PROTECTION SYSTEM | RUST STAGNANT WATER | LOW | YES | YES | SINGLE CHECK VALVE | CSC | 176-F | 2 1/2" | 0 | 1 | |||
| 103 FP | BLDG 457 RM 273 | FIRE PROTECTION SYSTEM | RUST STAGNANT WATER | LOW | YES | YES | SINGLE CHECK VALVE | 352 | 6" | 0 | 1 | ||||
| 104 FP | BLDG 457 RM 273 | FIRE PROTECTION SYSTEM | RUST STAGNANT WATER | LOW | YES | YES | SINGLE CHECK VALVE | AUTO SPRINKLER | D | 2 1/2" | 0 | 1 | |||
| 105 FP | BLDG 457 RM 273 | FIRE PROTECTION SYSTEM | RUST STAGNANT WATER | LOW | YES | YES | SINGLE CHECK VALVE | AUTO SPRINKLER | D | 2 1/2" | 0 | 1 | |||
| 106 FP | BLDG 457 RM 456 | FIRE PROTECTION SYSTEM | RUST STAGNANT WATER | LOW | YES | YES | SINGLE CHECK VALVE | AUTO SPRINKLER | 17.5F | 2 1/2" | 0 | 1 | |||
| 107 FP | BLDG 457 RM 456 | FIRE PROTECTION SYSTEM | RUST STAGNANT WATER | LOW | YES | YES | SINGLE CHECK VALVE | AUTO SPRINKLER | 17.5F | 2 1/2" | 0 | 1 | |||
| 108 FP | BLDG 457 RM 651 | FIRE PROTECTION SYSTEM | RUST STAGNANT WATER | LOW | YES | YES | SINGLE CHECK VALVE | 6" | VALVE PAINTED--NO MAKE OR MODEL | 0 | 1 | ||||
| 109 FP | BLDG 457 RM 6515 | FIRE PROTECTION SYSTEM | RUST STAGNANT WATER | LOW | YES | YES | SINGLE CHECK VALVE | AUTO SPRINKLER | 352 | 6" | 0 | 1 | |||
| 110 FP | BLDG 457 RM615 | FIRE PROTECTION SYSTEM | RUST STAGNANT WATER | LOW | YES | YES | SINGLE CHECK VALVE | 4" | VALVE PAINTED--NO MAKE OR MODEL | 0 | 1 | ||||
| 111 FP | BLDG 457 RM 593 | FIRE PROTECTION SYSTEM | RUST STAGNANT WATER | LOW | YES | YES | SINGLE CHECK VALVE | AUTO SPRINKLER | 4" | 0 | 1 | ||||
| INVENTORY OF CROSS-CONNECTION CONTROL AND BACKFLOW PREVENTION DEVICES | |||||||||||||||
| OFFUTT AFB | PERSONNEL MAKING INVENTORY: | ||||||||||||||
| CONTROL NO ISSUED | LOCATION | ITEM / FACILITY SYSTEM PROTECTED | POTENTIAL CONTAINMENT/POLLUTANT | DEGREE OF HAZARD / DEVICE SERIAL NUMBER | BACK PRESS POTENT | BACK SIPHONAGE POTENTIAL | TYPE CONTROL INSTALLED OR (REQUIRED) | DATA ON DEVICE INSTAL | COMMENTS | COMP | TOT | NXT YR. | TYPE # | ||
| MAKE | MODEL | SIZE | |||||||||||||
| 112 FP | BLDG 457 RM 551 | FIRE PROTECTION SYSTEM | RUST STAGNANT WATER | LOW | YES | YES | SINGLE CHECK VALVE | CSC | 2 1/2" | 0 | 1 | ||||
| 113 FP | BLDG 457 RM 551 | FIRE PROTECTION SYSTEM | RUST STAGNANT WATER | LOW | YES | YES | SINGLE CHECK VALVE | AUTO SPRINKLER | D | 2 1/2" | 0 | 1 | |||
| 114 FP | BLDG 457 BOILER RM | FIRE PROTECTION SYSTEM | RUST STAGNANT WATER | LOW | YES | YES | SINGLE CHECK VALVE | AUTO SPRINKLER | 6" | 0 | 1 | ||||
| 0 | 1 | ||||||||||||||
| 116 TEST | BLDG 457 RM 665 | C.W. MAKE-UP TO HYD. TEST STAND | HYDRAULIC OIL CHEMICALS | 233505 / HIGH | YES | YES | R.P.B.P. | WATTS | OO9 | 1" | TESTED DEVICE | 0 | 1 | 50/025 | |
| 117 TEST | BLDG 457 RM 665 | C.W. MAKE-UP TP WASH TANKS | CHEMICALS SOAP | 55146 / HIGH | YES | YES | R.P.B.P. | WATTS | OO9 | 1/2" | TESTED DEVICE | 0 | 1 | 50/026 | |
| 118 TEST | BLDG 457 RM 651 | C.W. MAKE-UP TO WELDERS | CHEMICALS | 89815 / HIGH | YES | YES | R.P.B.P. | WATTS | OO9 | 3/4" | TESTED DEVICE | 0 | 1 | 50/027 | |
| 119 TEST | C.W. SUPPLY TO BOILER | STAGNENT WATER / CHEMICALS | 228878 / HIGH | YES | YES | R.P.B.P. | WATTS | OO9 | 1/2" | Device removed | 0 | 1 | 3/6/07 | 50/028 | |
| 120 VB | BLDG 457 RM 636 | 2 HOSE BIBBS | CHEMICALS | HIGH | NO | YES | SCREW-ON VACUUM BREAKERS | WATTS | 8A | 5/8" | 0 | 1 | |||
| 121 TEST | BLDG 457 RM 593 | C.W. MAKEUP TO MANIFOLD TESTER | CHEMICALS | 55160 / HIGH | YES | YES | R.P.B.P. | WATTS | OO9 | 1/2" | TESTED DEVICE | 0 | 1 | 50/029 | |
| 122 VB | BLDG 457 RM 593 | 12 HOSE BIBBS 4 SERVICE SINKS | CHEMICALS | HIGH | NO | YES | SCREW ON VACUUM BREAKER | WATTS | 8A | 5/8" | 0 | 1 | |||
| 123 TEST | BLDG 304 CHILL | C.W. SUPPLY TO COOLING TOWER | STAG WATER / CHEMICALS | 120570 / HIGH | YES | YES | R.P.B.P. | WATTS | 909 | 21/2" | TESTED DEVICE | 0 | 1 | 50/030 | |
| INVENTORY OF CROSS-CONNECTION CONTROL AND BACKFLOW PREVENTION DEVICES | |||||||||||||||
| OFFUTT AFB | PERSONNEL MAKING INVENTORY: | ||||||||||||||
| CONTROL NO ISSUED | LOCATION | ITEM / FACILITY SYSTEM PROTECTED | POTENTIAL CONTAINMENT/POLLUTANT | DEGREE OF HAZARD / DEVICE SERIAL NUMBER | BACK PRESS POTENT | BACK SIPHONAGE POTENTIAL | TYPE CONTROL INSTALLED OR (REQUIRED) | DATA ON DEVICE INSTAL | COMMENTS | COMP | TOT | NXT YR. | TYPE # | ||
| MAKE | MODEL | SIZE | |||||||||||||
| 124 TEST | BLDG 493 EQUIP ROOM | C.W. SUPPLY TO BLDG ISOLATION | UNKNOWN | 20522 / HIGH | YES | YES | R.P.B.P. | WATTS | 909 | 3" | TESTED DEVICE | 0 | 1 | 2/25/14 | 50/245 |
| 125 TEST | BLDG 457 RM 564 | C.W. MAKEUP TO PARTS WASHER | CHEMICALS | 89762 / HIGH | YES | YES | R.P.B.P. | WATTS | 009M2 | 3/4" | TESTED DEVICE | 0 | 1 | 50/031 | |
| 126 TEST | BLDG 457 RM 944 | C.W. MAKEUP TO CHILLER & COOL TOWER | CHEMICALS | 89973 / HIGH | YES | YES | R.P.B.P. | WATTS | 009M1 | 2" | TESTED DEVICE | 0 | 1 | 50/032 | |
| 127 TEST | BLDG 457 RM 936 | SOAP RM. EQUIP, HEAT EX F/HEAT SYS. | SOAP CHEMICALS | HIGH / 14494 | YES | YES | R.P.B.P. | WATTS | 009m2 | 11/2" | TESTED DEVICE | 0 | 1 | 3/11/14 | 56/002 |
| 128 TEST | BLDG 457 RM 936 | C.W. MAKEUP TO BOILER | CHEMICALS | 07224 / HIGH | YES | YES | R.P.B.P. | WATTS | OO9 | 3" | TESTED DEVICE | 0 | 1 | 50/033 | |
| 129 TEST | BLDG 457 BOILER RM | C.W. MAKEUP TO BOILERS & CHILLERS | CHEMICALS | 20315 / HIGH | YES | YES | R.P.B.P. | WATTS | OO9 | 21/2" | TESTED DEVICE | 0 | 1 | 50/034 | |
| 130 TEST | BLDG 457 BOILER RM | C.W. MAKEUP TO DOM.H.W. HEAT EXCH. | CHEMICALS | 89974 / HIGH | YES | YES | R.P.B.P. | WATTS | OO9 | 2" | TESTED DEVICE | 0 | 1 | 50/035 | |
| 131 TEST | BLDG 493 RM 103 | COLD WATER SUPPLY TO BOILER | STAGNENT WATER / CHEMICALS | 228878 / HIGH | YES | YES | R.P.B.P. | WATTS | OO9 | 1/2" | TESTED DEVICE | 0 | 1 | 50/028 | |
| 132 TEST | BLDG 47 SE CORNER | C.W. MAKEUP TO IRRIG. SYS | CHEMICALS | A05214 / HIGH | YES | YES | R.P.B.P. | FEBCO | 860 | 1/2" | Not Currently Installed 4/27/07 | 0 | 1 | 4/27/10 | 50/061 |
| 134 TEST | BLDG 47 NE CORNER | C.W. MAKEUP TO IRRIG. SYS. | CHEMICALS | 215082 / HIGH | YES | YES | R.P.B.P. | WATTS | OO9 | 1/2" | Not Currently Installed 4/27/07 | 0 | 1 | 4/27/10 | 50/062 |
| 136 TEST | BLDG 29 ON FENCE | C.W. MAKEUP TO IRRIG. SYS. | CHEMICALS | 63402 / HIGH | YES | YES | R.P.B.P. | WATTS | OO9 | 1/2" | Not Currently Installed 4/27/07 | 0 | 1 | 4/27/10 | 50/063 |
| INVENTORY OF CROSS-CONNECTION CONTROL AND BACKFLOW PREVENTION DEVICES | |||||||||||||||
| OFFUTT AFB | PERSONNEL MAKING INVENTORY: | ||||||||||||||
| CONTROL NO ISSUED | LOCATION | ITEM / FACILITY SYSTEM PROTECTED | POTENTIAL CONTAINMENT/POLLUTANT | DEGREE OF HAZARD / DEVICE SERIAL NUMBER | BACK PRESS POTENT | BACK SIPHONAGE POTENTIAL | TYPE CONTROL INSTALLED OR (REQUIRED) | DATA ON DEVICE INSTAL | COMMENTS | COMP | TOT | NXT YR. | TYPE # | ||
| MAKE | MODEL | SIZE | |||||||||||||
| 138 TEST | BLDG 495 NORTH | C.W. MAKEUP TO HOSE BIBB | CHEMICALS | 566628 / HIGH | YES | YES | R.P.B.P. | WATTS | 909 | 3/4" | TESTED DEVICE 6/11/13 Robles/Bodell | 1 | 1 | 6/11/14 | 50/064 |
| 140 TEST | BLDG 592 LIFT STATION | C.W. MAKEUP TO HOSE BIBB | CHEMICALS | 290248/ HIGH | YES | YES | R.P.B.P. | WATTS | 909 | 3/4" | TESTED DEVICE | 0 | 2 | 50/065 | |
| 142 TEST | BLDG 552 | C.W. MAKEUP TO FIRE SUPPRESS | CHEMICALS/AFFF | 0011291346/ HIGH | YES | YES | R.P.B.P. | FEBCO | 860 | 4" | TESTED DEVICE 6/13/13 Alves | 1 | 2 | 6/13/14 | 50/066 |
| 143 TEST | 0 | 3 | |||||||||||||
| 146 TEST | 288 MECH RM | C.W. MAKEUP TO Lawn Irrigation | CHEMICALS | H08561/High | YES | YES | R.P.B.P. | FEBCO | 860 | 2" | TESTED DEVICE 3/19/2013 Robles/Dean | 1 | 3 | 3/19/14 | 50/68 |
| 148 TEST | 288 MECH RM | C.W. SUPPLY TO FIRE SUPPRESSION | STAGNET WATER | NW262 / LOW | YES | YES | R.P.B.P. | CONBRACO | 6DC | 6" | TEST DEVICE 3/18/13 ALVES | 1 | 4 | 3/18/14 | 50/069 |
| 150 TEST | 288 TRUCK BAY | C.W. SUPPLY TO FIRE TRUCK FILL | STAGNET WATER | F0302261124 / HIGH | YES | YES | R.P.B.P. | FEBCO | 860 | 4" | TEST DEVICE 3/19/13 ROBLES/Dean | 1 | 5 | 3/19/14 | 50/70 |
| 152 TEST | 288 TRUCK BAY | C.W. SUPPLY TO FIRE TRUCK FILL | STAGNET WATER | F0407151401 / HIGH | YES | YES | R.P.B.P. | FEBCO | 860 | 4" | TESTED DEVICE 3/11/13 ROBLES/Dean | 1 | 6 | 3/11/14 | 50/071 |
| 154 TEST | 288 MECH RM | C.W. SUPPLY TO BUILDING ISOLATION | CHEMICALS | HIGH / F0407151529 | YES | YES | R.P.B.P. | FEBCO | 860 | 3/4" | TESTED DEVICE 3/12/13 ROBLES/Dean | 1 | 7 | 3/12/14 | 50/072 |
| 156 TEST | BLDG 565 CSTS | C.W. MAKE-UP TO MISC. | CHEMICALS | HIGH / 18973 | YES | YES | R.P.B.P. | WATTS | OO9M3 | 3/4" | TESTED DEVICE 4/17/2013 Robles/Dean | 1 | 8 | 3/17/14 | 50/073 |
| 158 TEST | BLDG 9950 KITCH | COLD WATER SUPPLY TO SOAP DISP | CHEMICALS | A09492 / HIGH | YES | YES | R.P.B.P. | WATTS | OO9 | 1/2" | TESTED DEVICE 4/9/13 Robles/Dean | 1 | 9 | 4/9/14 | 50/074 |
| 160 TEST | BLDG 9950 KITCH | COLD WATER SUPPLY TO DISPOSER | SEWAGE | HIGH / A09920 | YES | YES | R.P.B.P. | WATTS | OO9 | 1/2" | TESTED DEVICE 4/9/13 Robles/DEAN | 1 | 10 | 4/9/14 | 50/075 |
| INVENTORY OF CROSS-CONNECTION CONTROL AND BACKFLOW PREVENTION DEVICES | |||||||||||||||
| OFFUTT AFB | PERSONNEL MAKING INVENTORY: | ||||||||||||||
| CONTROL NO ISSUED | LOCATION | ITEM / FACILITY SYSTEM PROTECTED | POTENTIAL CONTAINMENT/POLLUTANT | DEGREE OF HAZARD / DEVICE SERIAL NUMBER | BACK PRESS POTENT | BACK SIPHONAGE POTENTIAL | TYPE CONTROL INSTALLED OR (REQUIRED) | DATA ON DEVICE INSTAL | COMMENTS | COMP | TOT | NXT YR | TYPE # | ||
| MAKE | MODEL | SIZE | |||||||||||||
| 162 TEST | BLDG 809 FAM | C.W. SUPPLY TO FAM CAMP AREA | ISOLATION DEVICE | HIGH / 433881 | YES | YES | R.P.B.P. | WATTS | 909 | 2" | TESTED DEVICE 4/16/13 Robles/Dean | 1 | 11 | 4/16/14 | 50/361 |
| 164 TEST | 727 BOILER RM | C.W. MAKE-UP TO BOILER | CHEMICALS | 137493 / HIGH | YES | YES | R.P.B.P. | WATTS | 909 | 3/4" | Device is out of service, building is pickled. | 0 | 12 | 50/077 | |
| 166 TEST | 728 BOILER RM | C.W. MAKE-UP TO BOILER | CHEMICALS | 469431 / HIGH | YES | YES | R.P.B.P. | WATTS | 909 | 3/4" | Device is out of service, building is pickled. | 0 | 12 | 50/078 | |
| 168 TEST | 729 BOILER RM | C.W. MAKE-UP TO BOILER | CHEMICALS | 130257 /HIGH | YES | YES | R.P.B.P. | WATTS | 909 | 3/4" | Device is out of service, building is pickled. | 0 | 12 | 50/079 | |
| 170 TEST | 730 BOILER RM | C.W. MAKE-UP TO BOILER | CHEMICALS | 131566 / HIGH | YES | YES | R.P.B.P. | WATTS | 909 | 3/4" | BUILDING HAS BEEN DEADLINED | 0 | 12 | ||
| 172 TEST | 731 BOILER RM | C.W. MAKEUP TO BOILER | CHEMICALS | 469431 / HIGH | YES | YES | R.P.B.P. | WATTS | 909 | 3/4" | BUILDING HAS BEEN DEADLINED | 0 | 12 | ||
| 174 TEST | 732 BOILER RM | C.W. MAKE-UP TO BOILER | CHEMICALS | 128946 / HIGH | YES | YES | R.P.B.P. | WATTS | 909 | 3/4" | BUILDING HAS BEEN DEADLINED | 0 | 12 | ||
| 176 TEST | 733 BOILER RM | C.W. MAKE-UP TO BOILER | CHEMICALS | 128943 / HIGH | YES | YES | R.P.B.P. | WATTS | 909 | 3/4" | BUILDING HAS BEEN DEADLINED | 0 | 12 | ||
| 178 TEST | 734 BOILER RM | C.W. MAKE-UP TO BOILER | CHEMICALS | 130221 / HIGH | YES | YES | R.P.B.P. | WATTS | 909 | 3/4" | BUILDING HAS BEEN DEADLINED | 0 | 12 | ||
| 180 TEST | 735 BOILER RM | C.W. MAKE-UP TO BOILER | CHEMICALS | 128952 / HIGH | YES | YES | R.P.B.P. | WATTS | 909 | 3/4" | BUILDING HAS BEEN DEADLINED | 0 | 12 | ||
| 182 TEST | 736 BOILER RM | C.W. MAKE-UP TO BOILER | CHEMICALS | 118445 / HIGH | YES | YES | R.P.B.P. | WATTS | 909 | 3/4" | BUILDING HAS BEEN DEADLINED | 0 | 12 | ||
| 184 TEST | 737 BOILER RM | C.W. MAKE-UP TO BOILER | CHEMICALS | 130205 / HIGH | YES | YES | R.P.B.P. | WATTS | 909 | 3/4" | BUILDING HAS BEEN DEADLINED | 0 | 12 | ||
| INVENTORY OF CROSS-CONNECTION CONTROL AND BACKFLOW PREVENTION DEVICES | |||||||||||||||
| OFFUTT AFB | PERSONNEL MAKING INVENTORY: | ||||||||||||||
| CONTROL NO ISSUED | LOCATION | ITEM / FACILITY SYSTEM PROTECTED | POTENTIAL CONTAINMENT/POLLUTANT | DEGREE OF HAZARD / DEVICE SERIAL NUMBER | BACK PRESS POTENT | BACK SIPHONAGE POTENTIAL | TYPE CONTROL INSTALLED OR (REQUIRED) | DATA ON DEVICE INSTAL | COMMENTS | COMP | TOT | NXT YR. | TYPE # | ||
| MAKE | MODEL | SIZE | |||||||||||||
| 186 TEST | 738 BOILER RM | C.W. MAKE-UP TO BOILER | CHEMICALS | 118442 / HIGH | YES | YES | R.P.B.P. | WATTS | 909 | 3/4" | BUILDING HAS BEEN DEADLINED | 0 | 12 | ||
| 188 TEST | 739 BOILER RM | C.W. MAKE-UP TO BOILER | CHEMICALS | 128940 / HIGH | YES | YES | R.P.B.P. | WATTS | 909 | 3/4" | BUILDING HAS BEEN DEADLINED | 0 | 12 | ||
| 190 TEST | 740 BOILER RM | C.W. MAKE-UP TO BOILER | CHEMICALS | 118447 / HIGH | YES | YES | R.P.B.P. | WATTS | 909 | 3/4" | BUILDING HAS BEEN DEADLINED | 0 | 12 | ||
| 192 TEST | 741 BOILER RM | C.W. MAKE-UP TO BOILER | CHEMICALS | 118450 / HIGH | YES | YES | R.P.B.P. | WATTS | 909 | 3/4" | BUILDING HAS BEEN DEADLINED | 0 | 12 | ||
| 194 TEST | 742 BOILER RM | C.W. MAKE-UP TO BOILER | CHEMICALS | 139255 / HIGH | YES | YES | R.P.B.P. | WATTS | 909 | 3/4" | BUILDING HAS BEEN DEADLINED | 0 | 12 | ||
| 196 TEST | 743 BOILER RM | C.W. MAKE-UP TO BOILER | CHEMICALS | 118503 / HIGH | YES | YES | R.P.B.P. | WATTS | 909 | 3/4" | BUILDING HAS BEEN DEADLINED | 0 | 12 | ||
| 198 TEST | 744 BOILER RM | C.W. MAKE-UP TO BOILERS | CHEMICALS | 118439 / HIGH | YES | YES | R.P.B.P. | WATTS | 909 | 3/4" | BUILDING HAS BEEN DEADLINED | 0 | 12 | ||
| 200 TEST | 745 BOILER RM | C.W. MAKE-UP TO BOILER | CHEMICALS | 128953 / HIGH | YES | YES | R.P.B.P. | WATTS | 909 | 3/4" | BUILDING HAS BEEN DEADLINED | 0 | 12 | ||
| 202 TEST | 746 BOILER RM | C.W. MAKE-UP TO BOILER | CHEMICALS | 118509 / HIGH | YES | YES | R.P.B.P. | WATTS | 909 | 3/4" | BUILDING HAS BEEN DEADLINED | 0 | 12 | ||
| 204 TEST | 747 BOILER RM | C.W. MAKE-UP TO BOILER | CHEMICALS | 118440 / HIGH | YES | YES | R.P.B.P. | WATTS | 909 | 3/4" | BUILDING HAS BEEN DEADLINED | 0 | 12 | ||
| 206 TEST | 748 BOILER RM | C.W. MAKE-UP TO BOILER | CHEMICALS | 130250 / HIGH | YES | YES | R.P.B.P. | WATTS | 909 | 3/4" | BUILDING HAS BEEN DEADLINED | 0 | 12 | ||
| 208 TEST | 749 BOILER RM | C.W. MAKE-UP TO BOILER | CHEMICALS | 118404 / HIGH | YES | YES | R.P.B.P. | WATTS | 909 | 3/4" | BUILDING HAS BEEN DEADLINED | 0 | 12 | ||
| INVENTORY OF CROSS-CONNECTION CONTROL AND BACKFLOW PREVENTION DEVICES | |||||||||||||||
| OFFUTT AFB | PERSONNEL MAKING INVENTORY: | ||||||||||||||
| CONTROL NO ISSUED | LOCATION | ITEM / FACILITY SYSTEM PROTECTED | POTENTIAL CONTAINMENT/POLLUTANT | DEGREE OF HAZARD / DEVICE SERIAL NUMBER | BACK PRESS POTENT | BACK SIPHONAGE POTENTIAL | TYPE CONTROL INSTALLED OR (REQUIRED) | DATA ON DEVICE INSTAL | COMMENTS | COMP | TOT | NXT YR. | TYPE # | ||
| MAKE | MODEL | SIZE | |||||||||||||
| 210 FP | BLDG 586 | C.W. SUPPLY TO FIRE SUPPRESSION | RUST STAGNANT WATER | 0001261015/LOW | YES | YES | DCV | FEBCO | 770 | 6" | TESTED DEVICE | 0 | 12 | 56/029 | |
| 216 TEST | BLDG 585 LAB | C.W. MAKE-UP TO LAB SINK | CHEMICALS | 06122 / HIGH | YES | YES | R.P.B.P. | WATTS | OO9 | 3/8" | TESTED DEVICE | 0 | 12 | 50/081 | |
| 218 TEST | BLDG 524 RM. 227 | C.W. MAKE-UP TO SOAP DISP | CHEMICALS | A21625 / HIGH | YES | YES | R.P.B.P. | WATTS | 909 | 1/2" | TESTED DEVICE | 0 | 12 | 50/082 | |
| 220 TEST | BLDG 4000 ROOM GJ19-A | C.W. MAKE-UP TO STERLIZER | A12272 / HIGH | YES | YES | R.P.B.P. | WATTS | OO9 | 1/2" | Hospital Maintenence | 12 | 9/22/10 | 50/129 | ||
| 222 TEST | BLDG 4000 RM GJ16-A | C.W. MAKE-UP TO STEAM MACHINE | A03001 / HIGH | YES | YES | R.P.B.P. | WATTS | OO9 | 3/4" | Hospital Maintenence | 12 | 9/22/10 | 50/130 | ||
| 224 TEST | BLDG 4000 RM 1L13 | WATER SUPPLY TO STERILIZER | CHEMICALS | 06138 / HIGH | YES | YES | R.P.B.P. | WATTS | OO9 | 3/8" | Hospital Maintenence | 12 | 9/11/10 | 50/138 | |
| 226 TEST | BLDG 4000 RMGJ16B | WATER SUPPLY TO STERILIZER | CHEMICALS | 06136 / HIGH | YES | YES | R.P.B.P. | WATTS | OO9 | 3/8" | Hospital Maintenence | 12 | 9/22/10 | 50/132 | |
| 228 TEST | BLDG 4000 RMGJ19-B | WATER SUPPLY TO STERILIZER | CHEMICALS | 06125 / HIGH | YES | YES | R.P.B.P. | WATTS | OO9 | 3/8" | Hospital Maintenence | 12 | 9/22/10 | 50/080 | |
| 230 TEST | BLDG 4000 2P07 | WATER SUPPLY TO STERILIZER | CHEMICALS | A202111 / HIGH | YES | YES | R.P.B.P. | WATTS | OO9 | 3/4" | Hospital Maintenence | 12 | 9/16/10 | 50/087 | |
| 232 TEST | BLDG 4000 HOSP TOWER | SUPPLY FILTER COOLING TOWER | CHEMICALS | A26846 / HIGH | YES | YES | R.P.B.P. | WATTS | OO9 | 1/2" | Hospital Maintenence | 12 | 9/10/10 | 50/088 | |
| 234 TEST | Bldg 4000 rm 2p07 | C.W. MAKEUP TO Steris sterlizer | CHEMICALS | A25503 / HIGH | YES | YES | R.P.B.P. | WATTS | OO9 | 3/4" | Hospital Maintenence | 12 | 9/16/10 | 50/089 | |
| 236 TEST | Bldg 4000 Rm 2001 Dental | C.W. MAKEUP TO Curing Machine | UNKNOWN | A26774 / HIGH | YES | YES | R.P.B.P. | WATTS | OO9 | 1/2" | Hospital Maintenence | 12 | 9/22/10 | 50/090 | |
| INVENTORY OF CROSS-CONNECTION CONTROL AND BACKFLOW PREVENTION DEVICES | |||||||||||||||
| OFFUTT AFB | PERSONNEL MAKING INVENTORY: | ||||||||||||||
| CONTROL NO ISSUED | LOCATION | ITEM / FACILITY SYSTEM PROTECTED | POTENTIAL CONTAINMENT/POLLUTANT | DEGREE OF HAZARD / DEVICE SERIAL NUMBER | BACK PRESS POTENT | BACK SIPHONAGE POTENTIAL | TYPE CONTROL INSTALLED OR (REQUIRED) | DATA ON DEVICE INSTAL | COMMENTS | COMP | TOT | NXT YR. | TYPE # | ||
| MAKE | MODEL | SIZE | |||||||||||||
| 238 TEST | Bldg 4000 Rm G123-B | C.W. MAKEUP TO STERILIZER | UNKNOWN | A20212 / HIGH | YES | YES | R.P.B.P. | WATTS | OO9 | 3/4" | Hospital Maintenence | 12 | 9/22/10 | 50/091 | |
| 240 TEST | Bldg 4000 RM GJ15 | C.W. MAKEUP TO chem mix station | CHEMICALS | A21647 / HIGH | YES | YES | R.P.B.P. | WATTS | OO9 | 1/2" | Hospital Maintenence | 12 | 9/22/10 | 50/092 | |
| 242 TEST | Bldg 4000 Rm GB07-B | C.W. MAKEUP TO chem mix station | CHEMICALS | A12304 / HIGH | YES | YES | R.P.B.P. | WATTS | OO9 | 1/2" | Hospital Maintenence | 12 | 9/11/10 | 50/094 | |
| 244 TEST | Bldg 4000 Rm 217 | C.W. MAKEUP TO chem mix station | CHEMICALS | A21612 / HIGH | YES | YES | R.P.B.P. | WATTS | OO9 | 1/2" | Hospital Maintenence | 12 | 9/22/10 | 50/096 | |
| 246 TEST | Bldg 4000 Rm 1E41 | C.W. MAKEUP TO chem mix station | CHEMICALS | A21623 / HIGH | YES | YES | R.P.B.P. | WATTS | OO9 | 1/2" | Hospital Maintenence | 12 | 9/22/10 | 50/095 | |
| 248 TEST | Bldg 4000 Rm GJ05 | C.W. MAKEUP TO chem mix station | CHEMICALS | A26799 / HIGH | YES | YES | R.P.B.P. | WATTS | OO9 | 1/2" | Hospital Maintenence | 12 | 9/11/10 | 50/093 | |
| 250 TEST | Bldg 4000 Rm 261 | C.W. MAKEUP TO chem mix station | CHEMICALS | A12345/ HIGH | YES | YES | R.P.B.P. | WATTS | OO9 | 1/2" | Hospital Maintenence | 12 | 9/16/10 | 50/097 | |
| 252 TEST | Bldg 4000 Rm2P05 | C.W. MAKEUP TO chem mix station | CHEMICALS | HIGH / A26820 | YES | YES | R.P.B.P. | WATTS | OO9 | 1/2" | Hospital Maintenence | 12 | 9/11/10 | 50/098 | |
| 254 TEST | BLDG 4000 RM1K23 | C.W. SUPPLY TO CHEM DISP UNIT | CHEMICALS | A26923 / HIGH | YES | YES | R.P.B.P. | WATTS | OO9 | 1/2" | Hospital Maintenence | 12 | 9/11/10 | 50/099 | |
| 256 TEST | BLDG 4000 RM 232 | C.W. SUPPLY TO CHEM DISP UNIT | CHEMICALS | A26819 / HIGH | YES | YES | R.P.B.P. | WATTS | OO9 | 1/2" | Hospital Maintenence | 12 | 9/11/10 | 50/100 | |
| 258 TEST | BLDG 4000 RM 323 | C.W. SUPPLY TO CHEM DISP UNIT | CHEMICALS | A21571 / HIGH | YES | YES | R.P.B.P. | WATTS | OO9 | 1/2" | Hospital Maintenence | 12 | 9/11/10 | 50/101 | |
| 260 TEST | BLDG 4000 RMIL28 | C.W. SUPPLY TO CHEM DISP UNIT | CHEMICALS | A27987/ HIGH | YES | YES | R.P.B.P. | WATTS | OO9 | 1/2" | Hospital Maintenence | 12 | 9/11/10 | 50/102 | |
| INVENTORY OF CROSS-CONNECTION CONTROL AND BACKFLOW PREVENTION DEVICES | |||||||||||||||
| OFFUTT AFB | PERSONNEL MAKING INVENTORY: | ||||||||||||||
| CONTROL NO ISSUED | LOCATION | ITEM / FACILITY SYSTEM PROTECTED | POTENTIAL CONTAINMENT/POLLUTANT | DEGREE OF HAZARD / DEVICE SERIAL NUMBER | BACK PRESS POTENT | BACK SIPHONAGE POTENTIAL | TYPE CONTROL INSTALLED OR (REQUIRED) | DATA ON DEVICE INSTAL | COMMENTS | COMP | TOT | NXT YR. | TYPE # | ||
| MAKE | MODEL | SIZE | |||||||||||||
| 262 TEST | BLDG 4000 RM1L36 | C.W. SUPPLY TO CHEM DISP UNIT | CHEMICALS | A21559 / HIGH | YES | YES | R.P.B.P. | WATTS | OO9 | 1/2" | Hospital Maintenence | 12 | 9/11/10 | 50/103 | |
| 264 TEST | BLDG 4000 S MECH RM | C.W. SUPPLY BLDG ISOLATION | CHEMICALS / BIO | 252640 / HIGH | YES | YES | R.P.B.P. | WATTS | 909 | 6" | Hospital Maintenence | 12 | 9/23/10 | 50/104 | |
| 266 TEST | 301 BOILER RM | C.W. MAKE-UP TO HOT WATER BUNDLE | CHEMICALS | 468513 / HIGH | YES | YES | R.P.B.P. | WATTS | 909 | 3/4" | TESTED DEVICE 2/12/13 ROBLES/Dean | 1 | 12 | 2/13/14 | 50/105 |
| 268 TEST | BLDG 4000 RM 2P01 | WATER MAKE-UP TO STERLIZER | CHEMICALS | A10264 / HIGH | YES | YES | R.P.B.P. | WATTS | 909 | 1" | Hospital Maintenence | 13 | 3/4/10 | 50/106 | |
| 270 TEST | BLDG | C.W. SUPPLY TO BLDG | CHEMICALS | NBD83/LOW | YES | YES | R.P.B.P. | WATTS | Unkn | 1 | Device is out of service, building is pickled. | 0 | 13 | 5/11/10 | 50/107 |
| 272 TEST | 784 BOILER RM | C.W. MAKE-UP TO BOILER | CHEMICALS | 468511 / HIGH | YES | YES | R.P.B.P. | WATTS | 20002 | 3/4" | Device is out of service, building is pickled. | 0 | 13 | 4/12/02 | 50/108 |
| 274 TEST | 785 BOILER RM | C.W. MAKE-UP TO BOILER | CHEMICALS | 118423 / HIGH | YES | YES | R.P.B.P. | WATTS | 909 | 3/4" | Device is out of service, building is pickled. | 0 | 13 | 1/7/01 | 50/109 |
| 276 TEST | 786 BOILER RM | C.W. MAKE-UP TO BOILER | CHEMICALS | 130242 / HIGH | YES | YES | R.P.B.P. | WATTS | 909 | 3/4" | Device is out of service, building is pickled. | 0 | 13 | 50/110 | |
| 278 TEST | 787 BOILER RM | C.W. MAKE-UP TO BOILERS | CHEMICALS | 130229 / HIGH | YES | YES | R.P.B.P. | WATTS | 909 | 3/4" | Device is out of service, building is pickled. | 0 | 13 | 50/111 | |
| 285 A NEW | TRAINING EXC AREA | 1 FIRE HYDRANT | WATER | LOW | NO | YES | R.P.B.P. | WATTS | 009M2 | 2" | SOMETIMES CAN BE USED TO FILL WATER TRUCK. IF THAT HAPPENS A TEMP DEVICE IS INSTALLED | 0 | 13 | ||
| 286 TEST | Bldg 363 ARTS & CRAFTS | C.W. MAKE-UP TO BOILER | CHEMICALS | 89790 / HIGH | YES | YES | R.P.B.P. | WATTS | 009M2 | 3/4" | TESTED DEVICE 2/11/13 ROBLES/Dean | 1 | 13 | 50/112 | |
| 287 TEST | BLDG 282 | C.W SUPPLY TO BLDG ISOLATION | WATER | LK135 / LOW | YES | YES | RPBP | WILKINS | 40205TC2 | 1" | TESTED DEVICE | 0 | 14 | 60/005 | |
| INVENTORY OF CROSS-CONNECTION CONTROL AND BACKFLOW PREVENTION DEVICES | |||||||||||||||
| OFFUTT AFB | PERSONNEL MAKING INVENTORY: | ||||||||||||||
| CONTROL NO ISSUED | LOCATION | ITEM / FACILITY SYSTEM PROTECTED | POTENTIAL CONTAINMENT/POLLUTANT | DEGREE OF HAZARD / DEVICE SERIAL NUMBER | BACK PRESS POTENT | BACK SIPHONAGE POTENTIAL | TYPE CONTROL INSTALLED OR (REQUIRED) | DATA ON DEVICE INSTAL | COMMENTS | COMP | TOT | NXT YR. | TYPE # | ||
| MAKE | MODEL | SIZE | |||||||||||||
| 288 TEST | BLDG 282 | C.W. SUPPLY TO FIRE SUPPRN. | STAGNENT WATER / RUST | FH-2938 / LOW | YES | YES | D.C.V. | WATTS | 757 DC | 4" | TESTED DEVICE | 0 | 14 | 50/375 | |
| 289 TEST | BLDG 660 | C.W. SUPPLY TO UNKN | WATER | 48285/HIGH | YES | YES | RPBP | WATTS | 009QT | TESTED DEVICE | 0 | 14 | 50/115 | ||
| 290 TEST | BLDG 405 | C.W. MAKEUP TO AIR CONDITIONER | FREON OIL STAGNANT WATER | 124912/HIGH | YES | YES | R.P.B.P. | WATTS | 009M2 | 3/4" | Removed From Service 2/26/06 Robles/Pyle | 0 | 14 | 50/114 | |
| 292 TEST | BLDG 463 MECH RM | C.W. MAKEUP TO A/C & HEAT SYSTEM | CHEMICALS | 131549 / HIGH | YES | YES | R.P.B.P. | WATTS | 009M2 | 3/4" | TESTED DEVICE 2/19/13 ROBLES/Dean | 1 | 14 | 2/19/14 | 50/116 |
| 293 FP | BLDG 402 MECH RM | C.W. SUPPLY TO FIRE SUPPRESSION | RUST STAGNANT WATER | LOW / | YES | YES | D.C.V. | FEBCO | 850 | 4" | Bldg Pickeled 11/23/09 Will be torn down in the spring | 0 | 15 | ||
| 296 TEST | BLDG 400 MECH RM | C.W. MAKEUP TO HEAT SYSTEM | CHEMICALS | 114921 / HIGH | YES | YES | R.P.B.P. | WATTS | 909 | 3/4" | BLDG DESTROYED DEVICE REMOVED | 0 | 15 | 6/24/09 | 50/117 |
| 298FP | BLDG 400 MECH. | C.W. SUPPLY TO FIRE SUPR SYSTEM | RUST STAGNANT WATER | 9901261640 / LOW | YES | YES | D.C.V. | FEBCO | 850 | 21/2" | BLDG DESTROYED DEVICE REMOVED | 0 | 15 | 6/24/09 | 56/06 |
| 300 TEST | BLDG 402 MECH RM | C.W. MAKEUP TO HEAT SYSTEM | CHEMICALS | / HIGH | YES | YES | R.P.B.P. | WATTS | 909 | 3/4" | Bldg Pickeled 11/23/09 Will be torn down in the spring | 15 | 50/357 | ||
| 302 TEST | BLDG 402 MECH RM | C.W. MAKEUP TO DOM. H.W. HEAT EXCH. | CHEMICALS | / HIGH | YES | YES | R.P.B.P. | WATTS | OO9 | 11/2" | Bldg Pickeled 11/23/09 Will be torn down in the spring | 15 | 50/358 | ||
| 307 TEST | C.W. MAKEUP TO HEAT SYSTEM | CHEMICALS | HIGH | YES | YES | R.P.B.P. | WATTS | 909 | 3/4" | 0 | 15 | 50/118 | |||
| 308 TEST | BLDG 135 MECH | C/W SUPPLY TO BLDG ISOLATION | CHEMICALS | A02687 / HIGH | YES | YES | R.P.B.P. | WATTS | 009QT | 11/2" | TESTED DEVICE | 0 | 15 | 50/119 | |
| 309 TEST | BLDG 525 MECH RM | C.W. MAKE-UP TO HEAT SYS | CHEMICALS | 600592 / HIGH | YES | YES | R.P.B.P. | WATTS | 909 | 3/4 | TESTED DEVICE 2/19/13 ROBLES/Dean | 1 | 15 | 2/19/14 | 50/120 |
| INVENTORY OF CROSS-CONNECTION CONTROL AND BACKFLOW PREVENTION DEVICES | |||||||||||||||
| OFFUTT AFB | PERSONNEL MAKING INVENTORY: | ||||||||||||||
| CONTROL NO ISSUED | LOCATION | ITEM / FACILITY SYSTEM PROTECTED | POTENTIAL CONTAINMENT/POLLUTANT | DEGREE OF HAZARD / DEVICE SERIAL NUMBER | BACK PRESS POTENT | BACK SIPHONAGE POTENTIAL | TYPE CONTROL INSTALLED OR (REQUIRED) | DATA ON DEVICE INSTAL | COMMENTS | COMP | TOT | NXT YR. | TYPE # | ||
| MAKE | MODEL | SIZE | |||||||||||||
| 310 TEST | BLDG 525 MECH RM | C.W. MAKEUP TO DOM. H.W. HEAT EXCH. | CHEMICALS | 89977 / HIGH | YES | YES | R.P.B.P. | WATTS | 009M1 | 2" | TESTED DEVICE 2/19/13 ROBLES/Dean | 1 | 16 | 2/19/14 | 50/121 |
| 313 TEST | BLDG 526 MECH RM | C.W. MAKEUP TO HEAT SYSTEM | CHEMICALS | 114712 / HIGH | YES | YES | R.P.B.P. | WATTS | 909 | 3/4" | TESTED DEVICE2/20/13 ROBLES/Deanm | 1 | 17 | 2/20/14 | 50/122 |
| 314 TEST | BLDG 526 MECH RM | C.W. MAKEUP TO DOM. H.W.HEAT EXCH. | CHEMICALS | 89976 / HIGH | YES | YES | R.P.B.P. | WATTS | OO9 | 2" | TESTED DEVICE 2/20/13 ROBLES/DEAN | 1 | 18 | 2/20/14 | 50/123 |
| 317 TEST | BLDG 527 MECH RM | MASTER RPBP ON WATER SERVICE | UNKNOWN | N5888 / HIGH | YES | YES | R.P.B.P. | CON-BRACO | 4020902 | 21/2" | TESTED DEVICE 3/4/13 ROBLES/DEAN | 1 | 19 | 3/4/14 | 51/03 |
| 318 TEST | BLDG 527 MECH RM | C.W. MAKEUP TO HEAT SYSTEM | CHEMICALS | 568896 / HIGH | YES | YES | R.P.B.P. | WATTS | 909 | 1" | TESTED DEVICE 3/4/13 ROBLES/Dean | 1 | 20 | 3/4/14 | 51/04 |
| 321 TEST | BLDG 457 NDI RM | C.W. MAKEUP Film Develpor | CHEMICALS | HIGH/ 80560 | NO | YES | R.P.B.P. | WATTS | 009QT | 1/2" | TESTED DEVICE 6/3/13 Robles/Dean | 1 | 21 | 6/3/14 | 50/124 |
| 322 TEST | BLDG 451 MECH RM | C.W. MAKEUP TO COOLING TOWER | CHEMICALS / LEGIONAIRES DISEASE | HIGH 05657 | NO | YES | R.P.B.P. | WATTS | OO9 | 2 1/2" | TESTED DEVICE 6/3/13 Robles/Dean | 1 | 22 | 6/3/14 | 50/125 |
| 325 FS | BLDG 404 YOUTH CENTER | C.W. SUPPLY TO FIRE SUPR SYSTEM | RUST STAGNANT WATER | AH3484 LOW | YES | YES | D.C.V. | FEBCO | 805Y | 1" | TESTED DEVICE 2/14/13 Alves | 1 | 23 | 2/14/14 | 56/025 |
| 326 TEST | BLDG 9958 PATRIOT | C.W. SUPPLY TO HEAT SYSTEM | CHEMICALS / LEGIONAIRES DISEASE | HIGH / A02526 | YES | YES | R.P.B.P. | FEBCO | 860 | 1" | 2/23/2009 Removed from inventory, Tesred by Housing Maintenance | 0 | 24 | 2/23/10 | |
| 327 TEST | BLDG 9958 PATRIOT | C.W. SUPPLY TO FIRE SUPR SYSTEM | RUST STAGNANT WATER | LOW / 9954301217 | YES | YES | D.C.V. | FEBCO | 850 | 3" | 2/23/2009 Removed from inventory, Tesred by Housing Maintenance | 0 | 24 | 2/27/10 | |
| 328 TEST | BLDG 404 BOILER RM | C.W. MAKEUP TO BOILER FILL | CHEMICALS | 568627 / HIGH | YES | YES | R.P.B.P. | WATTS | 909 | 3/4" | TESTED DEVICE 1/28/13 Robles/Dean | 1 | 24 | 1/28/14 | 50/126 |
| 329 TEST | BLDG 565 Hanger Area | HOT WATER SUPPLY TO HOSE REEL | FUEL / SOAP CHEMICALS | 008855 / HIGH | YES | YES | P.V.B. | WATTS | 800M4 | 11/2" | TESTED DEVICE 4/22/13 Robles/Deanm | 1 | 25 | 4/22/14 | 50/323 |
| INVENTORY OF CROSS-CONNECTION CONTROL AND BACKFLOW PREVENTION DEVICES | |||||||||||||||
| OFFUTT AFB | PERSONNEL MAKING INVENTORY: | ||||||||||||||
| CONTROL NO ISSUED | LOCATION | ITEM / FACILITY SYSTEM PROTECTED | POTENTIAL CONTAINMENT/POLLUTANT | DEGREE OF HAZARD / DEVICE SERIAL NUMBER | BACK PRESS POTENT | BACK SIPHONAGE POTENTIAL | TYPE CONTROL INSTALLED OR (REQUIRED) | DATA ON DEVICE INSTAL | COMMENTS | COMP | TOT | NXT YR. | TYPE # | ||
| MAKE | MODEL | SIZE | |||||||||||||
| 331 TEST | BLDG 9958 BOILER RM | C.W. SUPPLY TO LOOP SYSTEM | RUST STAGNANT WATER | 67860 / HIGH | YES | YES | R.P.B.P. | WATTS | 009M2 | 1" | PATRIOT MAINTENCE TO TEST AND REPORT RESULTS TO MUD | 26 | 5/25/09 | 50/11 | |
| 333 TEST | BLDG 323 RM 119 | C.W. MAKEUP TO HEAT SYSTEM | CHEMICALS | 180242 / HIGH | YES | YES | R.P.B.P. | WATTS | 909 | 3/4" | TESTED DEVICE 2/11/13 ROBLES/Dean | 1 | 26 | 2/11/14 | 50/127 |
| 334 TEST | BLDG 362 | C.W. MAKEUP TO HOTSY CAR WASH | SOAP CHEMICALS | 63996 / HIGH | YES | YES | R.P.B.P. | WATTS | OO9 | 1/2" | TESTED DEVICE | 0 | 27 | 50/128 | |
| 335 FP | BLDG 362 MECH RM | FIRE PROTECTION SYSTEM | RUST STAGNANT WATER | LOW | NO | YES | SINGLE CHECK VALVE | 2 1/2" | 0 | 27 | |||||
| 337 TEST | BLDG 789 MECH RM | ISOLATION VALVE BETW EEN BASE & CITY | NONE | LOW | YES | YES | D.C.V. | WATTS | 709 | 2" | DEVICE TESTED BY OUTSIDE CONTRACTOR YEARLY FOR FAA | 0 | 27 | ||
| 338 TEST | BLDG 789 MECH RM | C.W. MAKEUP TO HEAT SYSTEM | CHEMICALS | 112350 / HIGH | YES | YES | R.P.B.P. | WATTS | 009M2 | 3/4" | DEVICE TESTED BY AN OUTSIDE CONTRACTOR YEARLY FOR FAA | 0 | 27 | ||
| 341 TEST | BLDG 789 OUTSIDE | LAWN SPRINKLERS SYSTEM | LAWN CHEMICALS | O7273 / HIGH | NO | YES | R.P.B.P. | WATTS | 009M2 | 11/4" | DEVICE TESTED BY AN OUTSIDE CONTRACTOR YEARLY FOR FAA | 0 | 27 | ||
| 342 TEST | BLDG 789 MECH RM | C.W. MAKEUP TO FLASH TANK | CHEMICALS STAGNANT WATER | O5151 / HIGH | YES | YES | R.P.B.P. | WATTS | OO9 | 1/2" | DEVICE IS NO LONGER IN USE, AND IS REMOVED | 0 | 27 | ||
| 343 TEST | BLDG 789 MECH RM | SOFT WATER MAKEUP TO BOILER | CHEMICALS STAGNANT WATER | 113588 / HIGH | YES | YES | R.P.B.P. | WATTS | 009M2 | 3/4" | DEVICE TESTED BY AN OUTSIDE CONTRACTOR YEARLY FOR FAA | 0 | 27 | ||
| 344 TEST | BLDG 280 MINI | C.W. SUPPLY TO SODA DISPENSER | 306204 / HIGH | YES | YES | R.P.B.P. | WATTS | 009M2 | 1/2" | TESTED DEVICE | 0 | 27 | 50/374 | ||
| INVENTORY OF CROSS-CONNECTION CONTROL AND BACKFLOW PREVENTION DEVICES | |||||||||||||||
| OFFUTT AFB | PERSONNEL MAKING INVENTORY: | ||||||||||||||
| CONTROL NO ISSUED | LOCATION | ITEM / FACILITY SYSTEM PROTECTED | POTENTIAL CONTAINMENT/POLLUTANT | DEGREE OF HAZARD / DEVICE SERIAL NUMBER | BACK PRESS POTENT | BACK SIPHONAGE POTENTIAL | TYPE CONTROL INSTALLED OR (REQUIRED) | DATA ON DEVICE INSTAL | COMMENTS | COMP | TOT | NXT YR. | TYPE # | ||
| MAKE | MODEL | SIZE | |||||||||||||
| 345 TEST | BLDG 280 MINI | POTABLE SUPPLY TO BLDG ISOLAT. | 258969 / HIGH | YES | YES | R.P.B.P. | WATTS | 009M2QT | 2" | TESTED DEVICE | 0 | 27 | 50/371 | ||
| 346 EXIST | BLDG 280 MINI | POTABLE SUPPLY TO LAWN IRRIG. | CHEMICAL | HIGH / 261258 | YES | YES | R.P.B.P. | WATTS | 009M2QT | 1" | TESTED DEVICE | 0 | 27 | 50/372 | |
| 347 EXIST | BLDG 280 MINI | POTABLE SUPPLY TO FIRE SUPPR. | RUST / STAGNENT WATER | HIGH/FJ3033 | YES | YES | D.C.V. | AMES | COLT 200 | 4" | TESTED DEVICE | 0 | 27 | 58/07 | |
| 348 TEST | BLDG 305 BOILER ROOM | C.W. MAKEUP TO WATR SOFTNR. & BOILER | SODIUM CHEMICALS | / HIGH | YES | YES | R.P.B.P. | WATTS | 909 | 3/4" | BLDG DESTROYED DEVICE REMOVED | 0 | 27 | 50/257 | |
| 354 TEST | BLDG 42 MECH RM | C.W. MAKEUP TO HEAT SYSTEM | CHEMICALS | 215795 / HIGH | YES | YES | R.P.B.P. | WATTS | 909 | 3/4" | TESTED DEVICE | 0 | 27 | 50/259 | |
| 356 TEST | BLDG 165 MECH RM | C.W. MAKEUP TO CHILLER | CHEMICALS | 63967 / HIGH | YES | YES | R.P.B.P. | WATTS | OO9 | 1/2" | BLDG DESTROYED DEVICE REMOVED | 0 | 27 | 2/20/09 | 50/263 |
| 357 TEST | BLDG 165 MECH RM | C.W. MAKEUP TO LAWN SPRINKLERS | LAWN CHEMICALS | 132919 / HIGH | NO | YES | R.P.B.P. | WATTS | 909 | 1 1/2" | BLDG DESTROYED DEVICE REMOVED | 0 | 27 | 2/20/09 | 50/134 |
| 358 TEST | BLDG 165 MECH RM | C.W. MAKEUP TO HEAT SYSTEM | CHEMICALS | 400745 / HIGH | YES | YES | R.P.B.P. | WATTS | 909 | 3/4" | BLDG DESTROYED DEVICE REMOVED | 0 | 27 | 2/20/09 | 50/135 |
| 360 TEST | BLDG 165 KITCHEN | C.W. MAKEUP TO POP DISPENSER EQUIP | CARBONATION SYRUP | 14144 / LOW | YES | YES | R.P.B.P. | WATTS | OO9M3 | 3/4" | BLDG DESTROYED DEVICE REMOVED | 0 | 27 | 2/20/09 | 50/136 |
| 365 TEST | BLDG 78 KITCHEN | C.W. TO WATER COOLED ICE MAKER | HIGH | YES | YES | R.P.B.P. | WATTS | OO9 | 1/2" | 0 | 27 | 50/137 | |||
| 366 TEST | NO | YES | R.P.B.P. | WATTS | 0 | 27 | |||||||||
| 367 TEST | CHEMICALS | YES | YES | R.P.B.P. | WATTS | 009 RT | 0 | 27 | 50/139 | ||||||
| INVENTORY OF CROSS-CONNECTION CONTROL AND BACKFLOW PREVENTION DEVICES | |||||||||||||||
| OFFUTT AFB | PERSONNEL MAKING INVENTORY: | ||||||||||||||
| CONTROL NO ISSUED | LOCATION | ITEM / FACILITY SYSTEM PROTECTED | POTENTIAL CONTAINMENT/POLLUTANT | DEGREE OF HAZARD / DEVICE SERIAL NUMBER | BACK PRESS POTENT | BACK SIPHONAGE POTENTIAL | TYPE CONTROL INSTALLED OR (REQUIRED) | DATA ON DEVICE INSTAL | COMMENTS | COMP | TOT | NXT YR. | TYPE # | ||
| MAKE | MODEL | SIZE | |||||||||||||
| 369 TEST | BLDG 327 MECH AREA | FIRE SUPRESSION SYSTEM | STAGNANT WATER / RUST | 05108 / LOW | YES | YES | D.C.V. | WATTS | 770 | 6" | TESTED DEVICE | 0 | 27 | 50/140 | |
| 370 TEST | C.W. MAKEUP TO DOM. H.W. HEAT EXCH. | STEAM CHEMICALS | YES | YES | R.P.B.P. | WATTS | 009M1 | 2" | Backflow Removed 12/23/08 Robles/pyle | 0 | 27 | 3/14/09 | 50/141 | ||
| 371 TEST | BLDG 41 BOILER RM | C.W. MAKEUP TO BOILERS | CHEMICALS | 258966 / HIGH | YES | YES | R.P.B.P. | FEBCO | 825Y | 2" | TESTED DEVICE | 0 | 27 | 56/07 | |
| 375 TEST | BLDG 41 MECH RM | C.W. MAKEUP TO CHILLER | CHEMICALS | 118412 / HIGH | YES | YES | R.P.B.P. | WATTS | 909 | 3/4" | DEVICE NO LONGER NEEDED. REMOVED 11/7/07 KIEPKE | 0 | 27 | 50/142 | |
| 376 TEST | BLDG 41 GARAGE | C.W. MAKE-UP TO BOILER | CHEMICALS SEWAGE | 159835 / HIGH | YES | YES | R.P.B.P. | WATTS | 909 | 3/4" | TESTED DEVICE 2/19/13 ROBLES/DEAN | 1 | 27 | 2/19/14 | 50/143 |
| 380 TEST | BLDG 113 MECH RM | C.W. MAKEUP TO CHILLER | CHEMICALS | 469445 / HIGH | YES | YES | R.P.B.P. | WATTS | 909 | 3/4" | Device Removed 7 Feb 13 Bldg. DEMO | 0 | 28 | 2/28/12 | 56/08 |
| 381 TEST | BLDG 113 MECH RM | C.W. MAKEUP TO WATER SOFTENER | SODIUM CHEMICALS | O5732 / LOW | YES | YES | R.P.B.P. | WATTS | 009M2 | 1 1/4" | Device Removed 7 Feb 13 Bldg. DEMO | 0 | 28 | 2/28/12 | 50/144 |
| 384 TEST | BLDG 113 BASEMENT | C.W. MAKEUP TO AIR COMP. COOLER | FREON OIL CHEMICALS | 57286 / HIGH | YES | YES | R.P.B.P. | WATTS | OO9 | 1/2" | Device Removed 7 Feb 13 Bldg. DEMO | 0 | 28 | 3/14/12 | 50/145 |
| 385 TEST | YES | YES | R.P.B.P. | WATTS | DEVICE REMOVED 3/2/04 | 0 | 28 | ||||||||
| 386 TEST | LAWN CHEMICALS | NO | YES | R.P.B.P. | WATTS | 909 | 1 1/4" | backflow Removed 08/18/11 Robles/Bodell | 0 | 28 | 6/6/12 | ||||
| 387 TEST | BLDG 113 DELI | C.W. MAKEUP TO SOAP DISPENSER | SOAP CHEMICALS | 57226 / HIGH | YES | YES | R.P.B.P. | WATTS | OO9 | 1/2" | Device Removed | 0 | 28 | 6/3/09 | 50/147 |
| 388 TEST | BLDG 113 CAVALIER LOUNGE | C.W. MAKEUP TO CARBONATORS | SYRUP CARBONATION | LOW | YES | YES | R.P.B.P. | WATTS | OO9 | 1/2" | Device Removed | 0 | 28 | ||
| INVENTORY OF CROSS-CONNECTION CONTROL AND BACKFLOW PREVENTION DEVICES | |||||||||||||||
| OFFUTT AFB | PERSONNEL MAKING INVENTORY: | ||||||||||||||
| CONTROL NO ISSUED | LOCATION | ITEM / FACILITY SYSTEM PROTECTED | POTENTIAL CONTAINMENT/POLLUTANT | DEGREE OF HAZARD / DEVICE SERIAL NUMBER | BACK PRESS POTENT | BACK SIPHONAGE POTENTIAL | TYPE CONTROL INSTALLED OR (REQUIRED) | DATA ON DEVICE INSTAL | COMMENTS | COMP | TOTAL | NXT YR. | TYPE # | ||
| MAKE | MODEL | SIZE | |||||||||||||
| 389 TEST | BLDG 113 BALL RM LOUNGE | C.W. MAKEUP TO CARBONATORS | SYRUP CARBONATION | 102015 / LOW | YES | YES | R.P.B.P. | WATTS | OO9 | 1/2" | Device Removed 7 Jan 13 Bldg. DEMO | 0 | 28 | 3/8/12 | 50/149 |
| 390 TEST | BLDG 113 BALL RM LOUNGE | C.W. MAKEUP TO CARBONATORS | SYRUP CARBONATION | 57204 / LOW | YES | YES | R.P.B.P. | WATTS | OO9 | 1/2" | Device Removed 7 Feb 13 Bldg. DEMO | 0 | 28 | 3/8/12 | 50/150 |
| 391 TEST | BLDG 13 2ND FLR | WATER COOLED COMPRESSOR | FREON | 06130 / HIGH | YES | YES | R.P.B.P. | WATTS | OO9 | 3/8" | TESTED DEVICE | 0 | 28 | 50/151 | |
| 396 TEST | BLDG 121 POOL AREA | C.W.MAKE-UP TO CHILD WADING POOL | CHEMICALS POOL WATER | 14702 / HIGH | NO | YES | R.P.B.P. | WATTS | OO9M2 | 1 1/2" | Device Removed | 0 | 28 | 50/229 | |
| 398 TEST | BLDG 73 MECH RM | C.W. MAKEUP TO BOILERS & AIR HANDLER | CHEMICALS | 112341 / HIGH | YES | YES | R.P.B.P. | WATTS | OO9 | 3/4" | TESTED DEVICE 3/18/13 ROBLES/DEAN | 1 | 28 | 3/18/14 | 50/152 |
| 402 TEST | LAWN CHEMICALS | / HIGH | NO | YES | R.P.B.P. | WATTS | 3/4" | 0 | 29 | 50/153 | |||||
| 403 TEST | C.W. MAKEUP TO DENTAL EQUIP | ANIMAL WASTE | NO | YES | R.P.B.P. | WATTS | OO9 | 1/2" | Backflow Removed 12/23/08 Robles/pyle | 29 | 3/10/09 | 50/154 | |||
| 404 TEST | BLDG 78 MECH RM | C.W. MAKE-UP TO WATER SOFTENER | A00298 / HIGH | YES | YES | R.P.B.P. | WATTS | OO9 | 1 1/4" | TESTED DEVICE | 0 | 29 | 50/155 | ||
| 405 TEST | BLDG 517 WASH RACK | C.W. MAKE-UP TO PART WASHER | FUEL / SOAP CHEMICALS | A28994 / HIGH | YES | YES | R.P.B.P. | WATTS | 009M2 | 3/4" | TESTED DEVICE | 0 | 29 | 50/156 | |
| 406 TEST | BLDG 552 MECH | COLD WATER SUPPLY TO BLDG | FUEL / SOAP CHEMICALS | 123986 / HIGH | YES | YES | R.P.B.P. | WATTS | 009M2 | 11/4" | TESTED DEVICE | 0 | 29 | 50/157 | |
| 407 TEST | BLDG 324 1 B WING | C.W. SUPPLY TO SOAP DISPENSER | SOAP CHEMICALS | A28585 / HIGH | YES | YES | R.P.B.P. | WATTS | OO9 | 1/2" | Device Removed 26 Apr 13 | 0 | 29 | 50/335 | |
| 408 TEST | BLDG 324 2 B WING | C.W. SUPPLY TO SOAP DISPENSER | SOAP CHEMICALS | A21608 / HIGH | YES | YES | R.P.B.P. | WATTS | OO9 | 1/2" | Device Removed 26 Apr 13 | 0 | 29 | 50/336 | |
| 409 TEST | BLDG 324 3 B WING | C.W. SUPPLY TO SOAP DISPENSER | SOAP CHEMICALS | A09233 / HIGH | YES | YES | R.P.B.P. | WATTS | OO9 | 1/2" | Device Removed 26 Apr 13 | 0 | 29 | 50/337 | |
| INVENTORY OF CROSS-CONNECTION CONTROL AND BACKFLOW PREVENTION DEVICES | |||||||||||||||
| OFFUTT AFB | PERSONNEL MAKING INVENTORY: | ||||||||||||||
| CONTROL NO ISSUED | LOCATION | ITEM / FACILITY SYSTEM PROTECTED | POTENTIAL CONTAINMENT/POLLUTANT | DEGREE OF HAZARD / DEVICE SERIAL NUMBER | BACK PRESS POTENT | BACK SIPHONAGE POTENTIAL | TYPE CONTROL INSTALLED OR (REQUIRED) | DATA ON DEVICE INSTAL | COMMENTS | COMP | TOTAL | NXT YR. | TYPE # | ||
| MAKE | MODEL | SIZE | |||||||||||||
| 411 TEST | BLDG 40 MECH RM 56 | C.W. MAKEUP TO HEAT SYSTEM | CHEMICALS | 11923 / HIGH | YES | YES | R.P.B.P. | WATTS | 009M1 | 1 1/4" | Device Removed | 0 | 29 | 3/17/04 | 50/158 |
| 413 TEST | BLDG. 49 MECH. RM. | C.W. TO DOM. H.W. HEAT EXCHANGER | STEAM CHEMICALS | O7271 / HIGH | YES | YES | R.P.B.P. | WATTS | 009M2 | 1 1/4" | Device Removed | 0 | 29 | 3/17/04 | 50/159 |
| 415 VB | BLDG 49 C.A.P. | 2 HOSE BIBBS ON SINK | CHEMICALS SEWAGE | HIGH | NO | YES | SCREW ON VACUUM BREAKERS | WATTS | 8A | 5/8" | Device Removed | 0 | 29 | ||
| 416 TEST | BLDG 49E RM. B110 | C.W. MAKEUP TO HEAT SYSTEM | CHEMICALS | / HIGH | YES | YES | R.P.B.P. | WATTS | 909 | 3/4" | Device Removed | 0 | 29 | 50/160 |