This document package includes drawings and specifications for the Creek Fire Beasore Road Repairs project, as well as the related federal contract opportunity solicitation. The project consists of repairing 5.49 miles of Beasore Road on the Sierra National Forest in California, including cleaning and reconditioning culverts, replacing 600 linear feet of 36-inch corrugated metal pipe, installing metal end sections and a metal spillway, performing 6 inches of full depth reclamation from mile post 24.14 to 29.63, installing geogrid, grading and compacting material, importing and placing base rock, installing riprap, placing a 4-inch layer of hot mix asphalt, and painting a double yellow center line. The solicitation is seeking offers for the project due by June 16, 2023 at 4:00 pm PDT, with an anticipated award value between $5-10 million. The work will be performed for the Department of Agriculture Forest Service.

View the file

Other files for this federal contract opportunity

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

PROJECT LOCATION

VICINITY MAP

SHEET OF001

INDEX OF SHEETS

SHEET SHEET TITLE DATE

1 COVER SHEET 3/26/2023

2 TYPICAL CROSS SECTIONS 3/26/2023

3 OVERSIDE DRAIN 3/26/2023

4 OVERSIDE DRAIN - DETAILS 3/26/2023

5 CULVERT DETAILS 3/26/2023

TRAVEL DIRECTIONS:

From Oakhurst, CA (93644), travel 3.2 miles North on highway 41, turn right onto Road 222/Bass Lake Road, continue South for approximately 2.4 miles, slight left onto Beasore Road, continue for approximately 33.5 miles until reach the beginning of the project (37.504292, -119.370184)

RECOMMENDED BY:

FOREST ENGINEER

DISTRICT RANGER DATE

DATE

FOREST SUPERVISOR DATE

United States Department of Agriculture

Forest Service

CREEK FIRE BEASORE ROAD REPAIRS

CALIFORNIA

MADERA COUNTY

SIERRA NATIONAL FOREST

(R05) PACIFC SOUTHWEST REGION

Map provided on separate document.

1.5 : 1 Backslope

2 : 1 Ditch

TYPICAL GRADING DETAIL - OUTSLOPE

Existing Ground

TYPICAL GRADING DETAIL - CROWNED TYPICAL GRADING DETAIL - INSLOPE

NOT TO SCALE

NOT TO SCALE NOT TO SCALE

Exist ing Ground

Varies (Avg 22')

2%

2:1Fill SlopeExisting Ground

Exist ing Ground

Varies (Avg 22')

2%

2:1Fill Slope

DEPTH AS STATED

IN WORK LIST

2%

Existing Ground

Exist ing Ground

2:1Fill Slope

DEPTH AS STATED

IN WORK LIST

1.5 : 1 Backslope

2 : 1 Ditch

2%

TYPICAL GRADING DETAIL - INSLOPE W/DITCH

NOT TO SCALE

Exist ing Ground

2:1Fill Slope

1.5 : 1 Backslope

2 : 1 Ditch

Existing Ground

Varies (Avg 22')

2%

Varies (Avg 22')

NOTE: Shoulder and travel way width varies.

Black

Yellow

DRAWING TITLE

DRAWN

DESIGNER

CHECKED

PROJECT NO.

OFSHEET

PROJECT NAME

DATE

ARCHIVE NO.

DWG SHEET NO.

(R05)

PACIFIC SOUTHWEST REGION

CREEK FIRE BEASORE

ROAD REPAIRS

MP 22.3 TO 29.7

SIERRA NATIONAL

FOREST

BASS LAKE

RANGER DISTRICT

TYPICAL CROSS

SECTIONS

03/26/2023

PABLO GONZALEZ

ANTONIO CABRERA

G-02

TYPICAL CROSS SECTIONS

TYPICAL CENTERLINE

THIS SECTION INTENTIONALLY LEFT BLANK.

INLET SECTION WING

STARTER SECTION WING

MAKE FROM 1/2 SHEET CUT

DIAGONALLY....SIZE

SHADED AREAS

INDICATE WASTE

SIDE VIEW-STARTER SECTION

S

T

A

N

D

A

R

D

L

E

N

G

T

H

I

N

F

SCHEDULE OF DIMENSIONS

(ALL DIMENSIONS ARE INCHES)

SEE DIMENSION SCHEDULE

ITEMS TYPICAL

INLET SECTION

WING(2)

INLET SECTION

JOIN WINGS TO INVERT AND CUT-OFF

PLATE WITH CONTINUOUS WELD,

INSIDE AND DOWN FACE.

INVERT &

CUT-OFF PLATE

NOTE:

JOIN IN FIELD, PUNCH HOLES

FOR ATTACHMENT AT TIME OF

INSTALLATION.

SPILLWAY INLET ASSEMBLY

STARTER SECTION

STARTER SECTION

JOIN WINGS TO INSIDE OF FLUME WITH ONE

CORRUGATION OVERLAP AND WELD FULL LENGTH.

SHOP PUNCH (2) IN REAR TO MATCH FLUME.

STARTER SECTION FLUME (1)

BEND AGAINST INSIDE RIDGE TO

FORM OPEN RADIUS BEND.

(APPROX. 3" DIA.)

SECTION A-A

GENERAL NOTES:

FABRICATION & WELDING:

TO BE IN ACCORD WITH FEDERAL SPECIFICATION.

MATERIALS:

INVERTS AND CUT-OFF PLATE (BOTH SIZES) MAKE

FROM 0.064" THICKNESS GALV. SHEER STEEL.

INLET AND STARTER:

STARTER AND STANDARD FLUME MAKE FROM FULL

OR ONE-HALF SIZE STANDARD CORRUGATED CULVERT

PIPE STOCK SHEET GALVANIZED STEEL.

24 INCH SIZE, 2-2/3" X 1/2" CORR. 0.064" THICKNESS

12 INCH SIZE, 2-2/3" X 1/2" CORR. 0.064" THICKNESS.

SLOT, TYPICAL (4)

PIECES 1/2" X 1" ON

HIP OF CORRUGATION

FLUME

DRAWING TITLE

DRAWN

DESIGNER

CHECKED

PROJECT NO.

OFSHEET

PROJECT NAME

DATE

ARCHIVE NO.

DWG SHEET NO.

(R05)

PACIFIC SOUTHWEST REGION

CREEK FIRE BEASORE

ROAD REPAIRS

MP 22.3 TO 29.7

SIERRA NATIONAL

FOREST

BASS LAKE

RANGER DISTRICT

OVERSIDE DRAIN

03/26/2023

PABLO GONZALEZ

ANTONIO CABRERA

G-03

OVERSIDE DRAIN

FIELD PUNCH 5/8" HOLES

OVERLAP 4"± AT ALL JOINTS,

UPPER SECTION INSIDE

BEGIN PAY QUANTITY

FOR RECTANGULAR

FLUME.

NATURAL GROUND OR

FILL SLOPE FACE

T

O

T

A

E

N

G

A

S

S

O

W

N

O

N

P

A

N

FLUME

FLUME INSTALLATION-TYPICAL

SEE SECTION A

STARTER SECTION

SPILLWAY INLET ASSEMBLY

INSTALLATION

ANCHOR STAKE-TYPICAL

(2)EACH JOINT INSTALL VERTICALLY

(SEE DETAIL & SECTION B-B)

GENERAL NOTES:

1-INLET, STARTER, AND FLUME SECTIONS SHALL BE JOINED

WITH 2-1/2"X2" BOLTS, 1/2" NUTS AND LOCK WASHERS.

INSTALL WITH BOLT HEAD ON INSIDE. FLUME

REQUIRES ONE BOLT EACH SIDE.

2-FIELD PUNCHED HOLES SHALL BE DEBURRED.

EXPOSED METAL SHALL BE COATED WITH ZINC

DUST-ZINC OXIDE & EXTERIOR ALUMINUM PAINT.

INLET SECTION

NOT TO SCALE

DRAWING TITLE

DRAWN

DESIGNER

CHECKED

PROJECT NO.

OFSHEET

PROJECT NAME

DATE

ARCHIVE NO.

DWG SHEET NO.

(R05)

PACIFIC SOUTHWEST REGION

CREEK FIRE BEASORE

ROAD REPAIRS

SIERRA NATIONAL

FOREST

BASS LAKE

RANGER DISTRICT

OVERSIDE DRAIN

(DETAILS)

03/26/2023

PABLO GONZALEZ

ANTONIO CABRERA

G-04

OVERSIDE DRAIN (DETAILS)

B

B

C

A

C

A

CATCH BASIN

TYPICAL PIPE INSTALLATION SECTION

A-A

TYPICAL RIPRAP INSTALLATION SECTION B-B

TYPICAL RIPRAP INSTALLATION

CULVERT INSTALLATION

DRAWING TITLE

DRAWN

DESIGNER

CHECKED

PROJECT NO.

OFSHEET

PROJECT NAME

DATE

ARCHIVE NO.

DWG SHEET NO.

(R05)

PACIFIC SOUTHWEST REGION

CREEK FIRE BEASORE

ROAD REPAIRS.

SIERRA NATIONAL

FOREST

BASS LAKE RANGER

DISTRICT

MAP

03/26/2023

PABLO GONZALEZ

ANTONIO CABRERA

G-05

Culvert Details