Attachment 2 Pricing Sheet.xlsx
XLSX spreadsheet 14 KB Posted
- Attached to
- Patient Monitoring System Federal contract opportunity
- Solicitation number
- FA558720Q1029
About this file
This document contains an attachment with pricing sheets and equipment lists for a patient monitoring system solicitation. The U.S. Air Force is seeking a turnkey solution for a patient monitoring system for the 48th Medical Group hospital at RAF Lakenheath, England. The requirement is for 32 patient monitors to be located in various departments including the ER, MSU, SCU, PACU, APU and OR. The pricing sheet lists the desired quantities, product prices and currencies for line items of patient monitors in each location. The monitors must have capabilities such as ECG, FAST SpO2, NIBP, RR, temperature, EtCO2 and invasive pressure monitoring. They must also be compatible with various medical record systems and able to slave data to an electronic charting system. Interested contractors are requested to provide pricing along with information such as estimated delivery dates, status of necessary approvals and contracting information.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| FA558720Q1029 Amendment 00003.pdf | ||
| Amendment 00002.pdf | ||
| Attachment I-Statement of Work 21 AUG 2020.pdf | ||
| FA558720Q1029 Amendment 00001.pdf | ||
| Attachment 4 MDERA.pdf | ||
| Solicitation FA558720Q1029.pdf | ||
| Attachment 3 DHA Cybersecurity-RMF Requirements (3-25-19).pdf | ||
| Attachment 1a ATO and ATC Sheeet.docx | DOCX document | |
| Attachment 1 Statement of Work.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
TAB A Equipment List & Location
| UNIT | Monitored Beds | Waveforms | Nellcore SpO2 | FAST SpO2 | EtCO2 | ECG 5 Lead | ECG 12 Lead | dual invas press/temp | Arterial Line Monitoring Cardiac Output Measuring/Monitoring | Salient Characteristics | Central Station | Telemetry (portable patient monitoring system w/ reusable batteries) | Interactive Review Station |
| E.R | 6 | 6 | X | X | X | X | X | At minimum. E.R needs 6 monitors capable for saving all data to Innovian electronic charting system for recording. Need to have MIB/RS232 board to connect to Essentris. All monitors will either be compatible with the cables and cuffs (ECG, BP cable and cuff, SPO2, and TEMP, EtCO2, ) Wall mounts for 6 monitors. Two GCX rails. Must work with Essentris, MHS Genesis, and CHCS, AHLTA | 1 | 0 | 1 | ||
| MSU and SCU | 11 | 6 | X | X | X | X | X | At minimum. MSU Needs 7 monitors with ECG, FAST SpO2, NIBP, RR, temperature and 3 waves, that can provide real time continuous patient monitoring. SCU needs 4 monitors with 6 waves, that are advanced real temi continuous patient monitoring for critical care and have ECG, SpO2, NIBP, RR, Temp, and all forms of invasive pressure monitoring (arterial lines pressure and central venous pressures). Must work with Essentris, MHS Genesis, AJLTA and CHCS | 2 | Qty 4 At minimum reads SpO2 | |||
| PACU | 3 | 6 | X | X | X | X | X | At minimum. The PACU (3 monitors) will require the same monitor specifications noted above but will need EtCO2 monitoring capability.All monitors will either be compatible with the cables and cuffs (ECG, BP cable and cuff, SPO2, and TEMP) that we already utilize in the hospital or new cables and cuffs will need to be purchased. onitors will be 100–240 V~, 45–65 Hz compatible and include a battery system with at least 30 minutes of battery life in case of power outage during use, or if needed for patient transport. 3 EtCO2 extensions with invasive press/temp. Must work with Essentris, MHS Genesis, AHLTA and CHCS | |||||
| 0 | Qty 2 At minimum reads SpO2 | ||||||||||||
| APU | 8 | 4 | X | X | X | X | X | At minimum. The APU requires 8 monitors that can provide real time continuous patient monitoring. The monitor needs to have the ability to measure: ECG, SpO2, NIBP, RR, and Temperature. Monitors will either be compatible with the cables and cuffs (ECG, BP cable and cuff, SPO2, and TEMP) that we already utilize in the hospital or new cables and cuffs will need to be purchasedMonitors will be 100–240 V~, 45–65 Hz compatible and include a battery system with at least 30 minutes of battery life in case of power outage during use, or if needed for patient transport. Must work with Essentris, MHS Genesis, AHLTA and CHCS | 0 | 0 | |||
| OR | 4 | 8 | X | X | X | X | X | operating rooms (4 monitors) advanced real time continuous patient monitoring equipment is required. Monitors are required for observing vital signs while the patient is under all types of anesthesia. Monitors will require the ability to monitor: ECG, SpO2, NIBP, RR, Temperature, and all forms of invasive pressure monitoring (arterial line pressures and central venous pressures). Monitors will be compatible and will allow for the input and display from the anesthetic gas analyzer (Phillips G7 Gas Analyzer) and monitors must have the capability to slave all data to the Innovian electronic charting system for recording. | 0 | 0 |
TAB B Pricing
| Contractor Name: |
| Email: |
| Phone: |
| Desired QTY | Offered Product | Price & Currency | ||
| Line Item 0001 | Patient Monitors E.R. | 6 Each | ||
| Line Item 0002 | Patient Monitors MSU and SCU | 11 each | ||
| Line Item 0003 | Patinet Monitors PACU | 3 each | ||
| Line Item 0004 | Patient Monitors APU | 8 each | ||
| Line Item 0005 | Patient Montiors OR | 4 each | ||
| TOTAL | 32 each |
Estimated Delivery/Installation Date: ___________________________
Status of ATO/ATC: _______________________________
Print Name:
Signature:
| DUNS: |
| CAGE Code: |
Comments: