Attachment 2 - Drawings.pdf

PDF 9 MB Posted

Attached to
Refurbish Motor Fans
Solicitation number
FA9101-25-SSMotorFans2
Issued by

About this file

The document is a detailed technical drawing set for a Space Heater Rack Assembly, part of a motor fan refurbishment project for NASA's Ames Research Center's National Full-Scale Aerodynamics Complex (NFAC) Wind Tunnels. The drawings provide precise manufacturing specifications for multiple components, including a base, wheel mount, bent platform, and support, with detailed dimensional annotations, material specifications (primarily mild steel), and assembly instructions. The drawings include isometric and orthographic views, with specific tolerances and notes about fabrication requirements, and are marked with a Distribution Statement A, indicating approval for public release with unlimited distribution.

The technical drawings are part of a Sources Sought Notice (Solicitation Number FA9101-25-SSMotorFans2) aimed at determining small and large business capabilities for motor fan refurbishment. The procurement may result in a small business set-aside, full and open competition, or potential single-source acquisition. Potential vendors are required to have an active SAM registration and a NIST SP 171-800 assessment with a score of 110. The project is being conducted by the Department of the Air Force Materiel Command Test Center, with the intent to use NAICS code 811310, and interested businesses are requested to submit capability statements, estimated pricing, and lead times for completing the motor fan service.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

10X 5.25

2X 3.25

8 12 X

5 2 X

1224 X

2024 X

215 X

19 2 X

32 X

64 X

7 4 X

11 4 X

10 16 X

8 8 X

9 4 X

1 SPACE HEATER RACK ASSY

ISO VIEW

SPACE HEATER RACK ASSY1

1348 X

1424 X

4X TYP.

2219 X

- CR 4112, SPACE HEATER RACK ASSEMBLY D.B. 2/23/2012 M.K.

REV. DESCRIPTION DRAWN DATE APPROVAL

REVISIONS

-1 CAGE

CODE

PART OR

IDENTIFYING NO. DESCRIPTION/NOMENCLATURE MATERIAL ZONE ITEM

NO.

X SPACE HEATER RACK ASSY 1

1 BASE 1/4" X 4" MILD STEEL 2

2 BENT PLATFORM 1/4" X 6" MILD STEEL 3

2 SUPPORT 1/4" X 6" MILD STEEL 4

2 WHEEL MOUNT 1/4" X 4" MILD STEEL 5

4 MMC 2310T51

(OR EQUIVALENT) V-WHEEL 6

4 1/2"-20 Hex Bolt 3" Long GRADE 8 STEEL 7

12 TEMPCO CSH00260 HEATER 8

8 MMC 5909K31

(OR EQUIVALENT) THRUST BEARINGS 9

4 1/2"-20 Nut GRADE 8 STEEL 10

16 MMC 5909K44

(OR EQUIVALENT) THRUST BEARING WASHERS 11

4 1/2" FLAT WASHER STEEL 12

24 #10-32 BOLT, LENGTH AS REQUIRED GRADE 5 STEEL 13

48 #10 FLAT WASHER STEEL 14

24 #10-32 LOCK NUT GRADE 5 STEEL 15

4 MMC 6460K41 BALL TRANSFER STUD 16

4 MMC 90977A130 COUPLING, 1/4-20 THRD 17

4 1/4-20 ALL THREAD, LENGTH AS REQUIRED 18

8 1/4-20 NYLON LOCK NUT 19

24 TEMPCO CER-101-104 CERAMIC TERMINAL COVER, 2 INLINE PORTS 20

5 TEMPCO CER-101-107 CERAMIC TERMINAL COVER, SINGLE PORT 21

19 TEMPCO CER-102-101 CERAMIC TERMINAL CAP, #10-32 THRD 22

NATIONAL FULL-SCALE AERODYNAMICS COMPLEX

NASA/Ames Research Center Moffett Field, California 94035

DATE

SURFACES TO BE

ALL MACHINED

AXIS TOTAL RUN OUT

DIAMETER ON SAME

ALL DIMENSIONS AND TOLERANCES APPLY AFTER SURFACE TREATMENT.

UNLESS OTHERWISE SPECIFIED ALL DIMENSIONS IN INCHES.

DRAWING DATE

DATEDESIGNED

TOLERANCE UNLESS OTHERWISE SPECIFIED

DIAMETER

DRILLED HOLE TOLERANCES

0VER 2.000

1.001-2.000

.501-1.000

.126- .500

.000- .125

SHEET

8 7 6 5 4 3 2

A

B

C

D

1345678

D

C

B

A

.XXX ± .005

.XX ± .02

DATE

DATE

DATE

DATECHECKED

DATEDRAWN

DWG. NO. REV SH.

A

SCALE: INDEX DATE

D

SIZE CAGE CODE

25307

OF

FILE NAME:

DO NOT SCALE

.X ± .1

FRACTIONAL ± 1/16

BREAK SHARP CORNERS REV

TOLERANCE

321-1230-M1

40X80X120 TEST SECTIONS+.005-.001

+.010-.002 +.015-.002 +.030-.003 +.060-.005

STRESS

PROJ MGR

SR & QA

A321-1230-M1

321-1230-M1.01.005

63 1 3

-A 1

NOTES:

1:8

NFAC

PARTS LISTQTY REQ'D PER ASSY

REQUESTER

SUPERVISOR

G. ROSETTO

M. KWAN

G. ROSETTO

2/23/2012

- NFAC WIND TUNNELS

FAN DRIVE MACHINES

SPACE HEATER ASSEMBLYANGULAR ± 0.5

MAX

12.0

4.0

8.0

2X R.25

.50

1.00

6.00

8.00

.25 STK

BASE

44.13

3X 2.00 4.0

02X

.0

2X

.5

2X

.0

.25 STK

WHEEL MOUNT

SCALE: 1:1

SHEET

8 7 6 5 4 3 2

A

B

C

D

1345678

D

C

B

A

DWG. NO. REV SH.

A

SCALE: INDEX DATE

D

SIZE CAGE CODE

25307

OF

FILE NAME:

REV

321-1230-M1

A321-1230-M1

321-1230-M1 2 3

-A 2

FMAT 3-94

1:3

27.88

6.0

6X 4.00

2X 22.75

6.0

12X .25

BENT PLATFORM

CL

3X 25.0

2X 170°

.25 STK

B

B

.25 STK

2X .75

2X 22.75

VIEW B-B

TWO LOCATIONS TYP.

SUPPORT

CL

SHEET

8 7 6 5 4 3 2

A

B

C

D

1345678

D

C

B

A

DWG. NO. REV SH.

A

SCALE: INDEX DATE

D

SIZE CAGE CODE

25307

OF

FILE NAME:

REV

321-1230-M1

A321-1230-M1

321-1230-M1 3 3

-A 3

FMAT 3-94

1:4

421-7830-MS103_SH1_dist A.pdf
A321-8140-MS5_dist A.pdf
A321-8140-MS3-Rev C_dist A.pdf
A321-8131-M935_Dist A.pdf
421-7830-MS103_SH2_dist A.pdf
A321-8131-M112_dist A.pdf
A321-1230-M1_dist A.pdf
Sheet1
Drawing View1
Drawing View2
Drawing View3
Sheet2
Drawing View5
Drawing View7
Drawing View8
Drawing View9
Sheet3
Drawing View16
Drawing View17
Drawing View19
Drawing View20
Drawing View21

File details come from the government source that posted it. Updated .