Attachment 2_Appendix A_ WR Security Equipment List sanatized.xlsx

XLSX spreadsheet 44 KB Posted

Attached to
Lenel United Technologies Maintenance Federal contract opportunity
Solicitation number
FA8501-20-Q-0018
Issued by
Department of the Air Force Materiel Command Air Force Sustainment Center

About this file

This document contains an equipment list and technical specifications for a federal security system. It details 64 Lenel reader licenses and associated servers, workstations, cameras, encoders, network video recorders, access control panels and over 40 doors with corresponding card readers. The system includes Lenel OnGuard access control and video management software. An intrusion detection system utilizing Honeywell control panels monitors perimeter zones and doors. Required maintenance under solicitation number FA8501-20-Q-0018 includes preventative and remedial support for the Lenel access control system, cameras, locks and digital video network at Building 228, Robins Air Force Base. The base year contract with four option years and a potential six month extension requires the contractor to be Lenel certified. Bids are due by September 17th, 2020.

View the file

Other files for this federal contract opportunity

Other files attached to Lenel United Technologies Maintenance, newest first.
File Type Posted
18 Jun 2020 dd1423 CDRL_A002 Security Equipment List.pdf PDF
18 Jun 2020 dd1423 CDRL_A003 Mishap Notification Report.pdf PDF
18 Jun 2020 dd1423 CDRL_A001 Industrial Safety and Health Plan.pdf PDF
Solicitation - FA850120Q0018 1.pdf PDF
No quote memo.pdf PDF
Attachment 1_21 July 2020 Performance Work Statement.pdf PDF
Attachment 3_Bldg 228 QASP.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Licenses

License Documentation
License TypeDescription# 0f LicensesLicense KeyServerTotal On Server
LenelReader License64DISAWRSEC164
LenelReader License64DISAWRSEC2
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0

Servers

Server Documentation
Unit NameDescriptionModelSerial #
DISAWRSEC1ACC Server - 1BCD360V8-M-MP-C135567-ACSMXQ50200WL
DISAWRSEC2ACC Server - 2 (Failover)BCD360V8-M-MP-C135567-ACSMXQ50200WV
DISAWRVID1LNVR ServerBCD380V8-M-VRP-C-135567-RS1USE443DD42

Workstations

Workstation Documentation
Unit NameModelSerial Number
DISAWRMON1BCD230S-M-CWS-135567-WS12UA5050YX3
DISAWRMON2BCD230S-M-CWS-135567-WS12UA5050YX8
DISAWRMON3BCD230S-M-CWS-135567-WS12UA5050YX2
DISAWRMON4BCD230S-M-CWS-135567-WS12UA5050YX9

Cameras

MakeModelNotes
AxisQ6035-E1
AxisP3365-V
AxisP3365-V
AxisP3365-V
AxisP3365-V
AxisP3365-VE
AxisP3365-V
AxisP3365-V
AxisP3365-V
AxisP3365-V
AxisP3365-V
AxisP3365-V
AxisP3365-V
AxisP3365-V
AxisP3365-V
AxisP3365-V
AxisP3365-V
AxisP3365-V
AxisP3365-VE
AxisP3365-VE
AxisP3365-V
AxisP3365-V
AxisP3365-V
AxisP3365-V
AxisP3365-V
AxisP3365-V
AxisP3365-V
AxisP3365-V
AxisP3365-V
AxisP3365-V
AxisP3365-V
AxisP3365-VE
AxisP3365-V
AxisP3365-V
AxisP3365-V
AxisP3365-V
AxisP3365-VE
AxisP3365-VE

Encoders

Encoder Documentation
Description/LocationMakeModel# of ChannelsIP AddressMAC AddressS/NNetwork SwitchPortLicenses UsedStatusNotes

NVR's

DVR Documentation
Unit NameModelSerial #IP AddressMAC AddressNetwork SwitchPort #StatusNotes

ACC Panels

ACC Panel Documentation
Panel #Panel DescriptionPanel TypePanel LocationControlling PanelNotes
1Controller 1LNL-2220ACP-1DISAWR - 2220 - 1
2Interface 2LNL-1320ACP-1Controller 1
3Interface 3LNL-1320ACP-1Controller 1
4Interface 4LNL-1320ACP-1Controller 1
5Interface 5LNL-1320ACP-1Controller 1
6Interface 6LNL-1320ACP-1Controller 1
7Interface 7LNL-1320ACP-1Controller 1
8Interface 8LNL-1320ACP-1Controller 1
9Interface 9LNL-1320ACP-2Controller 1
10Interface 10LNL-1320ACP-2Controller 1
11Interface 11LNL-1320ACP-2Controller 1
12Interface 12LNL-1320ACP-2Controller 1
13Interface 13LNL-1320ACP-2Controller 1
14Interface 14LNL-1320ACP-2Controller 1
15Interface 15LNL-1320ACP-2Controller 1
16Interface 16LNL-1320ACP-2Controller 1
17Interface 17LNL-1320ACP-3Controller 1
18Interface 18LNL-1320ACP-3Controller 1
19Interface 19LNL-1320ACP-3Controller 1
20Interface 20LNL-1320ACP-3Controller 1
21Interface 21LNL-1320ACP-3Controller 1
22Interface 22LNL-1320ACP-3Controller 1
23Interface 23LNL-1320ACP-3Controller 1
24Interface 24LNL-1320ACP-3Controller 1
25Interface 25LNL-1320ACP-4Controller 1
26Interface 26LNL-1320ACP-4Controller 1
27Interface 27LNL-1320ACP-4Controller 1
28Interface 28LNL-1320ACP-4Controller 1
29Interface 29LNL-1320ACP-4Controller 1
30Interface 30LNL-1320ACP-4Controller 1
31Interface 31LNL-1320ACP-4Controller 1
32Interface 32LNL-1320ACP-4Controller 1
33Controller 2LNL-2220ACP-5DISAWR - 2220 - 2
34Interface 2LNL-1320ACP-5Controller 2
35Interface 3LNL-1320ACP-5Controller 2
36Interface 4LNL-1320ACP-5Controller 2
37Interface 5LNL-1320ACP-5Controller 2
38Input 1LNL-1100ACP-5Controller 2
39Output 1LNL-1200ACP-5Controller 2

Readers

Reader Documentation
Reader #DescriptionModelSerial #Control PanelInterface PanelInput #StatusNotes
101 - Main Entrance #1 ENT

Matt Cherry: Matt Cherry:

Notes:

Existing Emergency Exit button previously installed on door has been hooked up to the RQE input and programmed to trip the door ouput. There is no siren or intrusion command sent out if pressed.HID6136CKN000709G30DISAWR - 2220 - 1DISAWR - 2220 - 10WorkingEmergency Exit Button Attached to new System
101 - Main Entrance #1 EXIT

Matt Cherry: Matt Cherry:

Notes:

Existing Emergency Exit button previously installed on door has been hooked up to the RQE input and programmed to trip the door ouput. There is no siren or intrusion command sent out if pressed.HID6125CGN0007G30LDISAWR - 2220 - 1DISAWR - 2220 - 11Working
202 - Admin Front ENT

Matt Cherry: Matt Cherry:

Notes:

Existing Emergency Exit pull station installed on door has been attached in line of the 24v power supply to kill power in the event it is tripped. There is no siren or intrusion command sent out if pressed.HID6136CKN000709G30DISAWR - 2220 - 1Interface 20WorkingEmergency Pull Station Attached
202 - Admin Front EXIT

Matt Cherry: Matt Cherry:

Notes:

Existing Emergency Exit pull station installed on door has been attached in line of the 24v power supply to kill power in the event it is tripped. There is no siren or intrusion command sent out if pressed.HID6125CGN0007G30LDISAWR - 2220 - 1Interface 21WorkingEmergency Pull Station Attached
303 - Main Entrance #2 ENT

Matt Cherry: Matt Cherry:

The door did not have an existing door contact. As it was not part of the scope to install new door contacts, it is still without one now.

There was an existing button on this door that has been removed.HID6136CKN000709G30DISAWR - 2220 - 1Interface 30WorkingNo Contact on Door
303 - Main Entrance #2 EXIT

Matt Cherry: Matt Cherry:

The door did not have an existing door contact. As it was not part of the scope to install new door contacts, it is still without one now.

There was an existing button on this door that has been removed.HID6125CGN0007G30LDISAWR - 2220 - 1Interface 31WorkingNo Contact on Door
404 - Room 181 NW ENT

Matt Cherry: Matt Cherry:

HID6136CKN000709G30DISAWR - 2220 - 1Interface 40Working
404 - Room 181 NW EXIT

Matt Cherry: Matt Cherry:

HID6125CGN0007G30LDISAWR - 2220 - 1Interface 41Working
505 - Admin Rear ENT

Matt Cherry: Matt Cherry:

The existing exit button has been removed from this door.

The door contact that was in place during the time of installation was broken. As it was not part of the scope of our work to install new door contacts it is still without one after our installation is complete.HID6136CKN000709G30DISAWR - 2220 - 1Interface 50WorkingBad Contact
505 - Admin Rear EXIT

Matt Cherry: Matt Cherry:

Matt Cherry:

Notes:

The existing exit button has been removed from this door.

The door contact that was in place during the time of installation was broken. As it was not part of the scope of our work to install new door contacts it is still without one after our installation is complete.HID6125CGN0007G30LDISAWR - 2220 - 1Interface 51WorkingBad Contact
606 - Comp Admin Room ENT

Matt Cherry: Matt Cherry:

HID6136CKN000709G30DISAWR - 2220 - 1Interface 60Working
606 - Comp Admin Room EXIT

Matt Cherry: Matt Cherry:

HID6125CGN0007G30LDISAWR - 2220 - 1Interface 61Working
707 - NS ENT

Matt Cherry: Matt Cherry:

Room that this door enters into at one point had it’s own "SCIF" like local security system. It was disabled before we arrived.HID6136CKN000709G30DISAWR - 2220 - 1Interface 70Working
707 - NS EXIT

Matt Cherry: Matt Cherry:

HID6125CGN0007G30LDISAWR - 2220 - 1Interface 71Working
808 - NS Back ENT

Matt Cherry: Matt Cherry:

Room that this door enters into at one point had it’s own "SCIF" like local security system. It was disabled before we arrived.HID6136CKN000709G30DISAWR - 2220 - 1Interface 80Working
808 - NS Back EXIT

Matt Cherry: Matt Cherry:

HID6125CGN0007G30LDISAWR - 2220 - 1Interface 81Working
909 - Comp Mech Room ENT

Matt Cherry: Matt Cherry:

This door has the only 12V only maglock in the entire building. As this was not understood when the initial wiring was put in, it has been adapted after the fact. Currently the 12V power is coming from the 12V distributor in the lower power supply and is triggered via the ground line going through the output relay on the 1320.HID6136CKN000709G30DISAWR - 2220 - 1Interface 90Working12V Maglock
909 - Comp Mech Room EXIT

Matt Cherry: Matt Cherry:

HID6125CGN0007G30LDISAWR - 2220 - 1Interface 91Working12V Maglock
1010 - Mechanical Room Main ENT

Matt Cherry: Matt Cherry:

HID6136CKN000709G30DISAWR - 2220 - 1Interface 100Working
1010 - Mechanical Room Main EXIT

Matt Cherry: Matt Cherry:

HID6125CGN0007G30LDISAWR - 2220 - 1Interface 101Working
1111 - Room 181 SW ENT

Matt Cherry: Matt Cherry:

The door contact on this door is a high security contact and as such is very sensistive. When the contact was installed the door was having some trouble closing and didn’t always show a "normal" state.

The door will need to be adjusted to repair the issue.HID6136CKN000709G30DISAWR - 2220 - 1Interface 110WorkingDoor Problems
1111 - Room 181 SW EXIT

Matt Cherry: Matt Cherry:

The door contact on this door is a high security contact and as such is very sensistive. When the contact was installed the door was having some trouble closing and didn’t always show a "normal" state.

The door will need to be adjusted to repair the issue.HID6125CGN0007G30LDISAWR - 2220 - 1Interface 111WorkingDoor Problems
1212 - Gazebo Gate ENT

Matt Cherry: Matt Cherry:

HID6136CKN000709G30DISAWR - 2220 - 1Interface 120Working
1212 - Gazebo Gate EXIT

Matt Cherry: Matt Cherry:

HID6125CGN0007G30LDISAWR - 2220 - 1Interface 121Working
1313 - Mechanical Room Compound ENT

Matt Cherry: Matt Cherry:

Notes:

Existing Emergency Exit pull station installed on door has been attached in line of the 24v power supply to kill power in the event it is tripped. There is no siren or intrusion command sent out if pressed.

HID6136CKN000709G30DISAWR - 2220 - 1Interface 130WorkingEmergency Pull Station Attached
1313 - Mechanical Room Compound EXIT

Matt Cherry: Matt Cherry:

Notes:

Existing Emergency Exit pull station installed on door has been attached in line of the 24v power supply to kill power in the event it is tripped. There is no siren or intrusion command sent out if pressed.HID6125CGN0007G30LDISAWR - 2220 - 1Interface 131WorkingEmergency Pull Station Attached
1414 - Comm Room ENT

Matt Cherry: Matt Cherry:

Notes:

The existing Door Contact is malfunctioning and will not report back properly. As the scope of our work does not inlcude repairing existing contacts or installing a new one on this door it was left inoperable.

Existing Emergency Exit pull station installed on door has been attached in line of the 24v power supply to kill power in the event it is tripped. There is no siren or intrusion command sent out if pressed.HID6136CKN000709G30DISAWR - 2220 - 1Interface 140WorkingBad Contact/ Emergency Pull Station Attached
1414 - Comm Room EXIT

Matt Cherry: Matt Cherry:

Notes:

The existing Door Contact is malfunctioning and will not report back properly. As the scope of our work does not inlcude repairing existing contacts or installing a new one on this door it was left inoperable.

Existing Emergency Exit pull station installed on door has been attached in line of the 24v power supply to kill power in the event it is tripped. There is no siren or intrusion command sent out if pressed.HID6125CGN0007G30LDISAWR - 2220 - 1Interface 141WorkingBad Contact/ Emergency Pull Station Attached
1515 - UPS Room ENT

Matt Cherry: Matt Cherry:

Notes:

Existing Emergency Exit pull station installed on door has been attached in line of the 24v power supply to kill power in the event it is tripped. There is no siren or intrusion command sent out if pressed.HID6136CKN000709G30DISAWR - 2220 - 1Interface 150WorkingEmergency Pull Station Attached
1515 - UPS Room EXIT

Matt Cherry: Matt Cherry:

Notes:

Existing Emergency Exit pull station installed on door has been attached in line of the 24v power supply to kill power in the event it is tripped. There is no siren or intrusion command sent out if pressed.HID6125CGN0007G30LDISAWR - 2220 - 1Interface 151WorkingEmergency Pull Station Attached
1616 - Compound Pedestrian Gate ENT

Matt Cherry: Matt Cherry:

HID6136CKN000709G30DISAWR - 2220 - 1Interface 160Working
1616 - Compound Pedestrian Gate EXIT

Matt Cherry: Matt Cherry:

HID6125CGN0007G30LDISAWR - 2220 - 1Interface 161Working
1717 - Comp Battery Room ENT

Matt Cherry: Matt Cherry:

HID6136CKN000709G30DISAWR - 2220 - 1Interface 170Working
1717 - Comp Battery Room EXIT

Matt Cherry: Matt Cherry:

HID6125CGN0007G30LDISAWR - 2220 - 1Interface 171Working
1818 - Comp Room Rear ENT

The existing Door Contact is malfunctioning and will not report back properly. As the scope of our work does not inlcude repairing existing contacts or installing a new one on this door it was left inoperable.

HID6136CKN000709G30DISAWR - 2220 - 1Interface 180WorkingBad Contact
1818 - Comp Room Rear EXIT
The existing Door Contact is malfunctioning and will not report back properly. As the scope of our work does not inlcude repairing existing contacts or installing a new one on this door it was left inoperable.HID6125CGN0007G30LDISAWR - 2220 - 1Interface 181WorkingBad Contact
1919 - Comp SMC ENT

Matt Cherry: Matt Cherry:

Notes:

Existing Emergency Exit Button was attached to the new system via the Aux Input 1. It is programmed to open the door and fire off a local siren for 30 seconds.

The local siren is on AUX Output 2.HID6136CKN000709G30DISAWR - 2220 - 1Interface 190WorkingEmergency Exit Button Attached to new System
1919 - Comp SMC EXIT

Matt Cherry: Matt Cherry:

Notes:

Existing Emergency Exit Button was attached to the new system via the Aux Input 1. It is programmed to open the door and fire off a local siren for 30 seconds.

The local siren is on AUX Output 2.HID6125CGN0007G30LDISAWR - 2220 - 1Interface 191WorkingEmergency Exit Button Attached to new System
2020 - Comp Security ENT

Matt Cherry: Matt Cherry:

Notes:

Existing Emergency Exit Button was attached to the new system via the Aux Input 1. It is programmed to open the door and fire off a local siren for 30 seconds.

The local siren is on AUX Output 2.HID6136CKN000709G30DISAWR - 2220 - 1Interface 200WorkingEmergency Exit Button Attached to new System
2020 - Comp Security EXIT

Matt Cherry: Matt Cherry:

Notes:

Existing Emergency Exit Button was attached to the new system via the Aux Input 1. It is programmed to open the door and fire off a local siren for 30 seconds.

The local siren is on AUX Output 2.HID6125CGN0007G30LDISAWR - 2220 - 1Interface 201WorkingEmergency Exit Button Attached to new System
2121 - Security ENT

The existing Door Contact is malfunctioning and will not report back properly. As the scope of our work does not inlcude repairing existing contacts or installing a new one on this door it was left inoperable.

Existing Emergency Exit Button was attached to the new system via the Aux Input 1. It is programmed to open the door and fire off a local siren for 30 seconds.

The local siren is on AUX Output 2.HID6136CKN000709G30DISAWR - 2220 - 1Interface 210WorkingBad Contact / Emergency Exit Button Attached to new System
2121 - Security EXIT

The existing Door Contact is malfunctioning and will not report back properly. As the scope of our work does not inlcude repairing existing contacts or installing a new one on this door it was left inoperable.

Existing Emergency Exit Button was attached to the new system via the Aux Input 1. It is programmed to open the door and fire off a local siren for 30 seconds.

The local siren is on AUX Output 2.HID6125CGN0007G30LDISAWR - 2220 - 1Interface 211WorkingBad Contact / Emergency Exit Button Attached to new System
2222 - SMC ENT

Matt Cherry: Matt Cherry:

HID6136CKN000709G30DISAWR - 2220 - 1Interface 220Working
2222 - SMC EXIT

Matt Cherry: Matt Cherry:

HID6125CGN0007G30LDISAWR - 2220 - 1Interface 221Working
2323 - Computer Room 177A ENT

Matt Cherry: Matt Cherry:

Notes:

- The existing Door Contact is malfunctioning and will not report back properly. As the scope of our work does not inlcude repairing existing contacts or installing a new one on this door it was left inoperable.

- The Exit button that was in place before we began has been removed.HID6136CKN000709G30DISAWR - 2220 - 1Interface 230WorkingBad Contact / Exit Button has been Removed
2323 - Computer Room 177A EXIT

Matt Cherry: Matt Cherry:

Notes:

- The existing Door Contact is malfunctioning and will not report back properly. As the scope of our work does not inlcude repairing existing contacts or installing a new one on this door it was left inoperable.

- The Exit button that was in place before we began has been removed.HID6125CGN0007G30LDISAWR - 2220 - 1Interface 231WorkingBad Contact / Exit Button has been Removed
2424 - Back Entrance NE ENT

Matt Cherry: Matt Cherry:

Notes:

Existing Emergency Exit button was attached to the new system to the RQE input. It is programmed to trip the door in the event it is pressed. There is no local siren.HID6136CKN000709G30DISAWR - 2220 - 1Interface 240WorkingEmergency Exit Button Attached to new System
2424 - Back Entrance NE EXIT

Matt Cherry: Matt Cherry:

Notes:

Existing Emergency Exit button was attached to the new system to the RQE input. It is programmed to trip the door in the event it is pressed. There is no local siren.HID6125CGN0007G30LDISAWR - 2220 - 1Interface 241WorkingEmergency Exit Button Attached to new System
2525 - Comp Room 177B ENT

Matt Cherry: Matt Cherry:

Notes:

- The Emergency Exit button was removed from this door.

HID6136CKN000709G30DISAWR - 2220 - 1Interface 250WorkingExit Button Removed
2525 - Comp Room 177B EXIT
- The Emergency Exit button was removed from this door.HID6125CGN0007G30LDISAWR - 2220 - 1Interface 251WorkingExit Button Removed
2626 - UPS B Rm 141 ENT

Matt Cherry: Matt Cherry:

Notes:

HID6136CKN000709G30DISAWR - 2220 - 1Interface 260Working
2626 - UPS B Rm 141 EXIT

Matt Cherry: Matt Cherry:

Notes:

HID6125CGN0007G30LDISAWR - 2220 - 1Interface 261Working
2727 - Battery Room 140 Exterior ENT

Matt Cherry: Matt Cherry:

HID6136CKN000709G30DISAWR - 2220 - 1Interface 270Working
2727 - Battery Room 140 Exterior EXIT

Matt Cherry: Matt Cherry:

HID6125CGN0007G30LDISAWR - 2220 - 1Interface 271Working
2828 - SE Entrance ENT

Matt Cherry: Matt Cherry:

HID6136CKN000709G30DISAWR - 2220 - 1Interface 280Working
2828 - SE Entrance EXIT

Matt Cherry: Matt Cherry:

HID6125CGN0007G30LDISAWR - 2220 - 1Interface 281Working
2929 - Supply Room ENT

Matt Cherry: Matt Cherry:

HID6136CKN000709G30DISAWR - 2220 - 1Interface 290Working
2929 - Supply Room EXIT

Matt Cherry: Matt Cherry:

HID6125CGN0007G30LDISAWR - 2220 - 1Interface 291Working
3030 - Mechanical Room 180 Exterior ENT

Matt Cherry: Matt Cherry:

Notes:

Due to an ongoing project on the base, this door's frame header has been removed and not re-installed. It is my understanding that the contractors responsible for the removal will be retunring to replace a large piece of equipment eventually and that the header will be reinstalled at that time. As such, no maglock is in place, and no door contact either. We have run all our wire down to the door and are fully prepared to attach the devices once they have retuned but until such time as they do we will be unable to complete this door.HID6136CKN000709G30DISAWR - 2220 - 1Interface 300WorkingHeader Removed, Door Incomplete.
3030 - Mechanical Room 180 Exterior EXIT

Matt Cherry: Matt Cherry:

Notes:

Due to an ongoing project on the base, this door's frame header has been removed and not re-installed. It is my understanding that the contractors responsible for the removal will be retunring to replace a large piece of equipment eventually and that the header will be reinstalled at that time. As such, no maglock is in place, and no door contact either. We have run all our wire down to the door and are fully prepared to attach the devices once they have retuned but until such time as they do we will be unable to complete this door.HID6125CGN0007G30LDISAWR - 2220 - 1Interface 301WorkingHeader Removed, Door Incomplete.
3131 - Computer Room 177C ENT

Matt Cherry: Matt Cherry:

Notes:

- The Exit button that was in place before we began has been removed.HID6136CKN000709G30DISAWR - 2220 - 1Interface 310WorkingExit Button Removed
3131 - Computer Room 177C EXIT

Matt Cherry: Matt Cherry:

Notes:

- The Exit button that was in place before we began has been removed.HID6125CGN0007G30LDISAWR - 2220 - 1Interface 311WorkingExit Button Removed
3232 - Outside Entrance Rm 178 ENT

Matt Cherry: Matt Cherry:

HID6136CKN000709G31DISAWR - 2220 - 1Interface 320Working
3232 - Outside Entrance Rm 178 EXIT

Matt Cherry: Matt Cherry:

HID6125CGN0007G30LDISAWR - 2220 - 1Interface 321Working
3333 - Back Entry to Supply ENT

Matt Cherry: Matt Cherry:

HID6136CKN000709G32DISAWR - 2220 - 2DISAWR - 2220 - 20Working
3333 - Back Entry to Supply EXIT

Matt Cherry: Matt Cherry:

HID6125CGN0007G30LDISAWR - 2220 - 2DISAWR - 2220 - 21Working
3434 - Loading Dock ENT

Matt Cherry: Matt Cherry:

HID6136CKN000709G33DISAWR - 2220 - 2Interface 20Working
3434 - Loading Dock EXIT

Matt Cherry: Matt Cherry:

HID6125CGN0007G30LDISAWR - 2220 - 2Interface 21Working
3535 - Loading Dock Rollup Door

Matt Cherry: Matt Cherry:

HID6136CKN000709G34DISAWR - 2220 - 2Interface 30Working
36Test Reader

Matt Cherry: Matt Cherry:

HID6125CGN0007G30LDISAWR - 2220 - 2Interface 31WorkingInstalled in Chuck's Office (170)
3736 - Mechanical Room 180 Interior ENT
The existing Door Contact is malfunctioning and will not report back properly. As the scope of our work does not inlcude repairing existing contacts or installing a new one on this door it was left inoperable.HID6136CKN000709G35DISAWR - 2220 - 2Interface 40WorkingBad Contact
3736 - Mechanical Room 180 Interior EXIT
The existing Door Contact is malfunctioning and will not report back properly. As the scope of our work does not inlcude repairing existing contacts or installing a new one on this door it was left inoperable.HID6125CGN0007G30LDISAWR - 2220 - 2Interface 41WorkingBad Contact
3737 - Battery Room 140 Interior ENT
The existing Door Contact is malfunctioning and will not report back properly. As the scope of our work does not inlcude repairing existing contacts or installing a new one on this door it was left inoperable.HID6136CKN000709G35DISAWR - 2220 - 2Interface 50WorkingBad Contact
3737 - Battery Room 140 Interior EXIT
The existing Door Contact is malfunctioning and will not report back properly. As the scope of our work does not inlcude repairing existing contacts or installing a new one on this door it was left inoperable.HID6125CGN0007G30LDISAWR - 2220 - 2Interface 51WorkingBad Contact
3838 - UPS Room 141 - Rear Door--DISAWR - 2220 - 2Input 1/Output 11WorkingMonitored/ Controlled Door only.
3939 - SMC - South Rear Door--DISAWR - 2220 - 2Input 1/Output 12WorkingMonitored/ Controlled Door only.
4040 - SMC - North Rear Door--DISAWR - 2220 - 2Input 1/Output 13WorkingMonitored/ Controlled Door only.
4141 - Smokers Gate--DISAWR - 2220 - 2Input 1/Output 14WorkingMonitored/ Controlled Door only.
4242 - Main Lobby - Side INT Door--DISAWR - 2220 - 2Input 15WorkingMonitored Door Only
4343 - Main Lobby - Side EXT Door--DISAWR - 2220 - 2Input 16WorkingMonitored Door Only

Software

Software Documentation
TypeModelVersion #Dongle ID
ACS and VideoLenel - Onguard7.0.1067.0107282

Intrusion

Intrusion Documentation
Zone #DescriptionDevice TypeDevice ModelPanel MakePanel ModelPanel DescriptionPanel LocationInput #Input Type
1Main Lobby Glass DCDoor Contact2707AD-LHoneywellVista 128BPDISA ISPIDS - 11Perimeter
2Room 181 NW DCDoor Contact2707AD-LHoneywellVista 128BPDISA ISPIDS - 12Perimeter
3Smoking Gate DCDoor Contact2707AD-LHoneywellVista 128BPDISA ISPIDS - 13Perimeter
4Room 181 SW DCDoor Contact2707AD-LHoneywellVista 128BPDISA ISPIDS - 14Perimeter
5Gazebo Gate DCDoor Contact2707AD-LHoneywellVista 128BPDISA ISPIDS - 15Perimeter
6Mechanical Room to Compound DCDoor Contact2707AD-LHoneywellVista 128BPDISA ISPIDS - 16Perimeter
7Compound Pedestrian Gate DCDoor Contact2707AD-LHoneywellVista 128BPDISA ISPIDS - 17Perimeter
8Battery Room 140 DCDoor Contact2707AD-LHoneywellVista 128BPDISA ISPIDS - 18Perimeter
9SE Entrance DCDoor Contact2707AD-LHoneywell4208UExpander - 1IDS - 21Perimeter
10UPS Room DCDoor Contact2707AD-LHoneywell4208UExpander - 1IDS - 22Perimeter
11Loading Dock DCDoor Contact2707AD-LHoneywell4208UExpander - 1IDS - 23Perimeter
12Back Entry to Supply Room DCDoor Contact2707AD-LHoneywell4208UExpander - 1IDS - 24Perimeter
13Outside Entrance to 178 DCDoor Contact2707AD-LHoneywell4208UExpander - 1IDS - 25Perimeter
14Back Entrance NE DCDoor Contact2707AD-LHoneywell4208UExpander - 1IDS - 26Perimeter
15Comp Room 177B DCDoor Contact2707AD-LHoneywell4208UExpander - 1IDS - 27Perimeter
16Mechanical Room 180 DCDoor Contact2707AD-LHoneywell4208UExpander - 1IDS - 28Perimeter

File details come from the government source that posted it. Updated .