Attachment 2 APPENDIX A - Building Inspection List.pdf

PDF 277 KB Posted

Attached to
FM200 System Inspection and Repairs Federal contract opportunity
Solicitation number
W911KF-21-Q-0046
Issued by
Department of the Army Materiel Command Contracting Command Detroit Arsenal

About this file

This document contains appendices detailing the fire suppression systems in various buildings requiring inspection and maintenance under the solicitation for an FM200 system inspection and repair contract. Appendix A provides tables listing the kitchen hood systems in different buildings by type of system, manufacturer, cylinder size, and other components. Appendices B, C, and D similarly provide tables outlining the communication room, production facility, and other building systems by location, type, manufacturer, number of cylinders, detectors, abort buttons, and notification devices. The solicitation seeks a contractor to perform semi-annual inspection, maintenance, and repairs of clean agent fire extinguishing systems, including FM200 and CO2, at multiple buildings across Anniston Army Depot in Alabama over a five year period in accordance with manufacturer specifications and contract requirements.

View the file

Other files for this federal contract opportunity

Other files attached to FM200 System Inspection and Repairs, newest first.
File Type Posted
Revised Statement of Work.pdf PDF
W911KF21Q0046_Amendment 0002.pdf PDF
W911KF21Q0046_Amendment 0001.pdf PDF
Attachment 3 APPENDIX B - Inspection and Maintenance Schedule.pdf PDF
Attachment 6 Past Performance Questionnaire.pdf PDF
W911KF21Q0046.pdf PDF
Attachment 1 Statement of Work.pdf PDF
Attachment 5 Request for Technical Literature.pdf PDF
Attachment 7 Wage Determination.pdf PDF
Attachment 4 Evidence of Authority to Sign Offers.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

APPENDIX A

Building Inspection List

P056-16 Page 12 Inspection, Test and Maintenance of Clean Agent Fire Extinguishing Systems, Carbon Dioxide Extinguishing Systems, and Kitchen Hood Systems October 2016

ATTACHMENT 1

Table 1. Kitchen Hood Systems

Type of System: Wet Chemical System

Buildings Type/Model Cylinder Size Fuse Links Pull Stations 47 Pyro-Chem PCL-600 6.0 gal 3 1

140 Pyro-Chem PCL-160 1.6 gal 3 1 141 Pyro-Chem PCL-300 3.0 gal 3 1

Pyro-Chem PCL-460 4.6 gal 3 1 Pyro-Chem PCL-460 4.6 gal 3 1

371 Pyro-Chem PCL-300 3.0 gal 3 1 Range Guard RG-4GM 4.0 gal 3 1

1500 Ansul R-102 1.5 gal 1 1 1530 Range Guard RG-4GM 4.0 gal 3 1

P056-16 Page 13 Inspection, Test and Maintenance of Clean Agent Fire Extinguishing Systems, Carbon Dioxide Extinguishing Systems, and Kitchen Hood Systems October 2016

ATTACHMENT 2

Table 2. Communication Rooms

Type of System: FM-200 Systems

Control Panel:

Fike (Bldgs. 362, 363 SIPR Room) Pyro-Chem (Bldgs. 52, 96, 97, 513)

Buildings Cylinders Pull

Stations Photo

Detectors Ion

Detectors Heat

Detectors Abort

Buttons Bells Horns Horn/

Strobes Strobes 52 1 1 1 1 — 1 1 — 1 — 96 1 1 2 2 — 1 1 — 1 — 97 2 1 3 3 — — 1 — 1 —

362 2 1 1 1 — 1 1 — 1 2 363 2 — 1 1 — — — — — — 513 1 1 3 3 — 1 1 — 1 —

P056-16 Page 14 Inspection, Test and Maintenance of Clean Agent Fire Extinguishing Systems, Carbon Dioxide Extinguishing Systems, and Kitchen Hood Systems October 2016

ATTACHMENT 3 – 3A

Table 3. Production Facilities Table 3A. Building 128

Type of Systems:

HFC-227 System (Dyno Cells, Control Rooms);

FM-200 System (M1 Test Cell, NDT Machine)

Control Panel: Fike

Building 128 Cylinders Pull

Stations Photo

Detectors Ion

Detectors Heat

Detectors Abort

Buttons Bells Horns Horn/

Strobes Strobes Dyno Cell 1 1 1 — — 2 1 — 1 1 1 Control Room 1 1 2 1 1 — 1 — 1 1 3 Dyno Cell 2 1 1 — — 2 1 — 1 1 1 Control Room 2 1 2 1 1 — 1 — 1 1 3 Dyno Cell 3 1 1 — — 2 1 — 1 1 1 Control Room 3 1 2 1 1 — 1 — 1 1 1 Dyno Cell 4 1 1 — — 2 1 — 1 1 — Dyno Cell 5 1 1 — — 2 1 — 1 1 1 M1 Test Cell 2 1 — — 4 1 2 — 2 — NDT Machine — — — — — — — — — —

P056-16 Page 15 Inspection, Test and Maintenance of Clean Agent Fire Extinguishing Systems, Carbon Dioxide Extinguishing Systems, ATTACHMENT 3 – 3B

Table 3B. Building 410

Type of Systems:

FM-200 System (Control Room of Test Cell 2);

CO2 System (All Test Cells)

Control Panel:

Ansul (Test Cells);

Chemetron (Control Room #2)

Building 410 Cylinders

Stations Photo

Detectors Ion

Detectors Heat

Detectors Abort

Buttons Bells Horns Horn/

Strobes Strobes Control Room 2 1 2 2 2 — 2 — — 2 1

Test Cell 2 See Note 1 — — 3 — 1 — 1 2 Test Cell 3 See Note 1 — — 3 — 1 — 1 1 Test Cell 4 See Note 1 — — 3 — 1 — 1 1 Test Cell 5 See Note 1 — — 3 — 1 — 1 1 Test Cell 6 See Note 2 — — 3 — 1 — 1 2 Test Cell 7 See Note 2 — — 3 — 1 — 1 2 Test Cell 8 See Note 2 — — 3 — 1 — 1 2 Test Cell 9 See Note 2 — — 3 — 1 — 1 2

Test Cell 10 See Note 2 — — 3 — 1 — 1 2 Test Cell 11 See Note 1 — — — — — — — 2 Test Cell 12 See Note 1 — — — — 1 — 1 2 Test Cell 13 See Note 1 — — 3 — 1 — 1 2 Test Cell 14 See Note 1 — — 3 — 1 — 1 2 Test Cell 15 See Note 1 — — 3 — 1 — 1 2 Test Cell 16 See Note 1 — — 3 — 1 — 1 2 Test Cell 17 See Note 1 — — 3 — 1 — 1 2 Test Cell 18 See Note 1 — — 3 — 1 — 1 2 Test Cell 19 See Note 1 — — 3 — 1 — 1 2 Test Cell 20 See Note 2 1 1 2 — 2 — 4 2

NOTE:

Test Cells 2-10: A set of 12 Cylinders – 75 LB CO2 Cylinder with CV98 Valves Test Cells 11-19: A set of 12 Cylinders – 75 LB CO2 Cylinder with CV98 Valves Test Cell 20: A set of 12 Cylinders – 100 LB CO2 Cylinder with CV98 Valves

P056-16 Page 16 Inspection, Test and Maintenance of Clean Agent Fire Extinguishing Systems, Carbon Dioxide Extinguishing Systems, ATTACHMENT 3 – 3C

Table 3C. Building 474

Type of System: FM-200 System

Control Panel: Fike

Building 474 Cylinders

Stations Photo

Detectors Ion

Detectors Heat

Detectors Abort

Buttons Bells Horns Horn/

Strobes Strobes Dyno Cell 1 2 2 2 2 2 1 — — 2 3 Dyno Cell 2 2 2 2 2 2 1 — — 2 3 Dyno Cell 3 2 2 2 2 2 1 — — 1 3 Dyno Cell 4 2 2 2 2 2 1 — — 2 3 Dyno Cell 5 2 2 2 2 2 1 — — 2 3 Dyno Cell 6 2 2 2 2 2 1 — — 2 3 Dyno Cell 7 2 2 2 2 2 1 — — 2 3

P056-16 Page 17 Inspection, Test and Maintenance of Clean Agent Fire Extinguishing Systems, Carbon Dioxide Extinguishing Systems, ATTACHMENT 3 – 3D

Table 3D. Building 475

Type of System: FM-200 System

Control Panel:

Notifier (Dyno Cells);

Fike (Control Room 405)

Building 475 Cylinders

Stations Duct

Detectors Ion

Detectors Heat

Detectors Abort

Buttons Bells Horns Horn/

Strobes Strobes Dyno Cell 401 2 2 2 — 4 2 3 — 3 — Dyno Cell 402 2 2 4 — 6 2 3 — 3 — Dyno Cell 403 2 2 2 — 4 2 3 — 3 — Dyno Cell 404/405 4 2 4 — 6 2 4 — 4 —

Control Rm 405 1 1 — — 2 1 1 — 1 2 Dyno Cell 406 2 2 2 — 4 2 3 — 3 — Dyno Cell 407 2 2 2 — 4 2 3 — 3 — Dyno Cell 408 2 2 4 — 6 2 3 — 3 — Dyno Cell 409 2 1 — — 4 1 1 — 1 1 Dyno Cell 410 4 2 2 — 6 2 3 — 3 — Dyno Cell 411 2 2 2 — 4 2 3 — 3 —

End of Scope of Work

SOW QA70-20 FM200, dated 7-6-2021 11
SOW QA70-20 FM200, dated 7-6-2021 12
SOW QA70-20 FM200, dated 7-6-2021 13
SOW QA70-20 FM200, dated 7-6-2021 14
SOW QA70-20 FM200, dated 7-6-2021 15
SOW QA70-20 FM200, dated 7-6-2021 16
SOW QA70-20 FM200, dated 7-6-2021 17

File details come from the government source that posted it. Updated .