This document outlines technical specifications for 2000W step-up transformers for residential use. The Department of State's European Logistics Support Office requires the transformers to have the following specifications: output of 110/120VAC from an input of 220/240VAC as an auto-transformer; a clearly labeled red polarity warning light; a ground fault circuit interrupter or comparable safety feature; a minimum wattage of 2000W as a single phase unit; thermal protection; a portable design with handle and dimensions suitable for weight; an indicator pilot light; a European three-prong SCHUKO plug; raised non-conducting feet to ensure no contact with surfaces; color coded internal wiring suitable for heat generation and rated for temperatures from -5 to 40 degrees Celsius; copper rather than aluminum windings; and wiring sizes to carry the rated current capacity. The related federal contract opportunity is solicitation number 19BE1022Q5006 for 2000W transformers for residential use converting 110v to 220v through the Department of State.

View the file

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Transformer Specifications The Department of State's European Logistics Support Office (ELSO) requires 2000W step-up transformers for residential use with the following specifications:

No.
Requirements
Pass/Fail
1
220/240VAC to 110/120 VAC
2
Auto-Transformer w/ Red Polarity Warning Light (or Isolation)
3
Polarity warning light is clearly labeled “Light on, Polarity Reversed”
4
Ground Fault Circuit Interrupter (GFCI) safety feature or comparable which will discontinue input power if any ground current or 10mA or more is sensed
5
Minimum Wattage: 2000W
6
Single Phase
7
Unit is thermally protected
8
Portable: handle, size, and weight
9
Indicator Pilot Light (Indicating the unit is ON)
10
Possesses label with UL listed or UL recognized symbols or independent testing agency equivalent***
11
European three-prong SCHUKO plug
12
Should rest on raised non-conducting feet or minimum (2 cm) to assure no contract with the set-up surface.
13
All internal wiring should be color coded
14
All internal wiring should be temperature rated to withstand heat generated from transformer
15
Suitable for ambient operation between -5 to 40 degrees Celsius
16
Windings should be cooper not aluminum conductors
17
Wiring sizes shall be provided to carry the current capacity of the transformer rating size

Notes:

* Polarity warning light must be clearly labeled on the unit "Light on, Polarity Reversed or comparable."

* Unit that is provided with a Green Polarity OK light is acceptable. Must be labeled. Red polarity OK light is not acceptable.

** To prevent potential shock hazards, customer requires a two-pole Ground Fault Interrupter (GFI) safety feature that will discontinue the supply of input power to the voltage converter unit if any ground fault current or 10 mA or more is sensed.

*** If other independent listing agency is used, TÜV, CSA, VDE, online verification site information must be provided.

**The GFI device shall be wired to sense ground fault current paths related to the unit’s metallic components as well as any ground fault paths via connected appliances plugged into the unit’s output receptacles.

***GOV reserves the right to accept or reject independent agency listing if NOT verifiable online, i.e.. www.ul.com/database , https://www.tuev-sued.de/product-testing/certificates.

***Documentation describing labeling as "UL accepted", "UL approved", or "UL certified" alone will not be accepted. The unit must be appropriately marked.

***CE is not a recognized independent testing agency and will not be accepted.

***The submitted technical data must be verifiable against publicly available/online information.