Attachment_1_Lincoln_Park_GC_IrrigationDesign.pdf

PDF 4 MB Posted

Attached to
EXT REC | CON27-0007 Lincoln Park Irrigation- MLBE
Solicitation number
SFGOV-0000012108
Issued by
San Francisco County, San Francisco City, California

About this file

This is an irrigation design attachment for the City and County of San Francisco Recreation and Park Department related to a Micro LBE Set-Aside solicitation for irrigation work at Lincoln Park Golf Course. The project encompasses automation and renovation of the irrigation system for Holes 1, 13, 17, and 18 at the golf course located at 300 34th Ave, San Francisco, CA 94121. Work includes furnishing and installing 1.5" Schedule 40 electrical conduit for two-wire cable, extending conduit and cable to existing remote control valves, installing new valve boxes, furnishing and installing Toro Lynx Smart Module Decoders, replacing existing Hunter ACC controllers with Toro Smart Hubs, and renovating irrigation infrastructure including new sprinkler installations, main line connections, and isolation valves. The design plans detail specifications for C900 PVC plastic pipe ranging from 2" to 6" in diameter, Toro rotary pop-up sprinklers with valve-in-head and smart module integration, grounding requirements with copper rods and surge arrestors, and comprehensive electrical and communication wiring installations. A non-mandatory pre-bid meeting is scheduled for Tuesday, October 6, 2026 at 10:00 AM at Lincoln Golf Course, with bids due no later than Tuesday, October 20, 2026 by 2:30 PM, submitted via email to bridget.webster@sfgov.org.

The project cost estimate is $408,000 and requires contractors to hold either an A or C-27 license. This is a Micro Local Business Enterprise (LBE) Set-Aside solicitation, restricting bidding eligibility to certified Micro LBE firms. The design documentation includes detailed irrigation plans, system upgrade specifications, and technical installation requirements for recycled water systems, including mandatory recycled water labeling, warning tags, and color-coded piping (purple). Contractor responsibilities include field verification of all existing irrigation equipment locations prior to construction, maintaining water supply to existing irrigation systems during construction, hand excavation in areas adjacent to trees, proper grounding of all electrical equipment in compliance with manufacturer specifications, and completion of field staking of sprinklers with minimum three-day notice to the irrigation consultant.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

CITY AND COUNTY OF SAN FRANCISCO

RECREATION AND PARK DEPARTMENT ADMINISTRATION

ATTACHMENT 1

See Next Page

CONTROLLER "S"

CONTROLLER "13"

13GR1

S

M

2" WM (#23115135)

2.5" 2.5"

2.5"

13FW3

13FW1

18FW1

18FW2

18FW3

13FW2

19GR1

1TE1

1FW2

M

A

N

J

M

A

N

G

M

A

N

G

M

A

N

G

C

C

M

A

N

F

M

A

N

H

M

A

N

H

M

A

N

K

M

A

N

K

M

A

N

K

M

A

N

E

M

A

N

E

M

A

N

E

M

A

N

E

MAN-D

M

A

N

D

C

C

M

A

N

M

M

A

N

M

M

A

N

M

M

A

N

L

M

A

N

N

C

M

A

N

L

M

A

N

H

M

A

N

H

M

A

N

G

M

A

N

L

L

E

G

I

O

N

F

H

N

R

D

R

I

V

E

CLEMENT STREET

CALIFORNIA

STREET

MARVEL CT

r d

A

V E

PG

C

L

U

B

H

O

U

S

E

B

B

B

B

1FW1

18GR1

LA

LA

PLAN NOTES NOTES:

1 FURNISH & INSTALL 1.5" SCH 40 ELECTRICAL CONDUIT FOR 2/C #14 AWG CABLE AS DETAILED

(TYPICAL)

2 EXTEND NEW CONDUIT AND 2/C #14 AWG CABLE TO EXISTING REMOTE CONTROL VALVES.

INSTALL NEW VALVE BOX ON EXISTING REMOTE CONTROL VALVE AS DETAILED. FURNISH & INSTALL TORO LYNX SMART MODULE DECODER TO EACH EXISTING REMOTE CONTROL VALVE AS DETAILED.

CONNECT 2/C #14 AWG CABLE TO LYNX SMART MODULE AS DETAILED. (TYPICAL)

3 EXTEND NEW CONDUIT AND 2/C #14 AWG CABLE TO EXISTING REMOTE CONTROL VALVES.

INSTALL NEW VALVE BOX ON EXISTING REMOTE CONTROL VALVE AS DETAILED. FURNISH &

INSTALL TORO LYNX SMART MODULE DECODER TO EACH EXISTING REMOTE CONTROL

VALVE AS DETAILED. CONNECT 2/C #14 AWG CABLE TO LYNX SMART MODULE AS DETAILED.

(TYPICAL)

MATCHLINE SEE SHEET I-2

APPROXIMATE LOCATION

OF A 30 x 40 STAGING

AREA FOR LINCOLN PARK

fax 925.932.5671tel 925.939.3985 www.rmairrigation.com

2760 Camino Diablo Walnut Creek, CA 94597 t

Russell D. Mitchell Associates, Inc.

Irrigation Consultant:

IRRIGATION PLAN

AUTOMATION OF HOLES 1, 13, & 18

I-1

1"=60'

CALL BEFORE YOU DIG

UNDERGROUND SERVICE ALERT

30' 120'60'0

SCALE:

EXISTING IRRIGATION NOTES:

1. ALL EXISTING IRRIGATION SHOWN IN GREY IS EXISTING AND SHALL REMAIN IN SERVICE. USE CAUTION

WHEN GRADING OR TRENCHING NEAR EXISTING IRRIGATION. EXACT ROUTING OF IRRIGATION

MAINLINE, WIRES, LOCATION OF SPRINKLERS/VALVE SHOULD BE INVESTIGATED PRIOR TO

CONSTRUCTION. CONTRACTOR WILL NEED TO FIELD VERIFY THE LOCATION OF ALL EXISTING

IRRIGATION EQUIPMENT PRIOR OF CONSTRUCTION. THE USE OF A WIRE TRACER REQUIRED.

CONTRACTOR TO NOTIFY IRRIGATION CONSULTANT OR GOLF COURSE SUPERINTENDENT IF THERE

ARE ANY PROBLEMS PRIOR TO CONSTRUCTION.

2. CONTRACTOR IS RESPONSIBLE TO KEEP ALL EXISTING IRRIGATION (TO REMAIN) WITH WATER AT ALL TIMES DURING CONSTRUCTION. THIS MAY INCLUDE PROVIDING TEMPORARY WATER SOURCE DURING

CONSTRUCTION.

CONTROLLER "C"

C

C-13

C-14

C-15

C-10

C-8

C-9

C-4

C-3

C-1

C-16

C-18

C-6

C-5

C-2

B-8

C-12

C-11

4"

4"

4"

LOCATION OF MAIN

LINE CONNECTION

TO GOLF COURSE

LOCATED IN FIELD.

CONNECTION TO

GOLF COURSE IS

LOCATED IN FIELD.

B

B

18TE1

16RO1

2"

2"

2"

2"

2"

2"

2"

2"

2"

2"

2"

2"

2"

2"

2"

2"

2"

2"

2"

2"

2"

3"

2"

2"

2"

2"

2"

2"

2"

2"

M

A

N

C

M

A

N

C

M

A

N

B

M

A

N

B

M

A

N

B

M

A

N

A

M

A

N

A

C

C

B

A

T

B

A

T

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C-3

C

C

C

C

C

C

C

C

C

C

C

C

C

C

M

A

N

M

M

A

N

C

C

C

C

C

B

B

C

C

B

C

C

C

B

B

C

M

A

N

B

M

A

N

B

B

B

L

I

N

C

O

L

W

Y

LIN

C

O

LN

H W

Y

B

B

LA

LA

LA

LA

LA

LA

APPROXIMATE LOCATION OF EXISTING 6"

TRANSITE MAIN LINE. POT HOLE AND LOCATE IN

FIELD. GOLF COURSE STAFF WILL ASSIST IN

LOCATING THE PIPE. CONNECT NEW MAIN LINE

TO EXISTING ASBESTOS CEMENT PIPE WITH A

ROMAC STYLE 501 LONG BARREL REPAIR

COUPLING OR APPROVED EQUAL. ASSUMED SIZE

OF EXISTING A/C PIPE IS 6". EXPOSE AND

MEASURE PRIOR TO ORDERING COUPLING.

SAWCUT EXISTING ROAD A MINIMUM OF 10' FROM NEWLY

INSTALLED IMPROVEMENTS. INSTALL 2-1.5" SCH 40

ELECTRICAL CONDUITS (1 SPARE & 1 FOR TWO WIRE

CABLE) WITHIN TRENCH ACROSS ROADWAY. REPAIR

SAWCUT AS REQUIRED TO MATCH EXISTING ROAD BASE

AND PAVING PROFILE. EXACT LOCATION OF SAWCUT SHALL

BE APPROVED BY CITY REPRESENTATIVE.

MATCHLINE SEE SHEET I-1

SYSTEM UPGRADE/SHEET SPECIFIC RETROFIT

MODIFICATION KEYNOTES:

1 REPLACE EXISTING HUNTER ACC 2-WIRE CONTROLLER

WITH TORO SMART HUB. CONNECT EXISTING TWO

WIRE THAT WAS ROUTED FROM EXISTING

CONTROLLER INTO SMART HUB. ROUTE NEW 1.25"

CONDUIT AND TWO WIRE CABLE OF A DIFFERENT

COLOR TO SERVICE EXISTING REMOTE CONTROL

VALVES AND NEW SPRINKLERS ON HOLE #17.

2 FURNISH & INSTALL 1.5" SCH 40 ELECTRICAL CONDUIT

FOR 2/C #14 AWG CABLE AS DETAILED (TYPICAL)

3 EXTEND NEW CONDUIT AND 2/C #14 AWG CABLE TO

EXISTING REMOTE CONTROL VALVES. INSTALL NEW

VALVE BOX ON EXISTING REMOTE CONTROL VALVE AS

DETAILED. FURNISH & INSTALL TORO LYNX SMART

MODULE DECODER TO EACH EXISTING REMOTE

CONTROL VALVE AS DETAILED. CONNECT 2/C #14 AWG

CABLE TO LYNX SMART MODULE AS DETAILED.

(TYPICAL)

4 REMOVE EXISTING QUICK COUPLERS ONCE NEW

SYSTEM IS OPERATIONAL. FILL VOIDS WITH TOP SOIL.

(TYPICAL ON HOLE #17)

5 FURNISH & INSTALL TORO LYNX SMART MODULE

DECODER TO EACH EXISTING REMOTE CONTROL

VALVE AS DETAILED (TYPICAL)

fax 925.932.5671tel 925.939.3985 www.rmairrigation.com

2760 Camino Diablo Walnut Creek, CA 94597 t

Russell D. Mitchell Associates, Inc.

Irrigation Consultant:

IRRIGATION PLAN

HOLE 17 RENOVATION

I-2

1"=60'

CALL BEFORE YOU DIG

UNDERGROUND SERVICE ALERT

30' 120'60'0

SCALE:

EXISTING IRRIGATION NOTES:

1. ALL EXISTING IRRIGATION SHOWN IN GREY IS EXISTING AND SHALL

REMAIN IN SERVICE. USE CAUTION WHEN GRADING OR TRENCHING

NEAR EXISTING IRRIGATION. EXACT ROUTING OF IRRIGATION

MAINLINE, WIRES, LOCATION OF SPRINKLERS/VALVE SHOULD BE

INVESTIGATED PRIOR TO CONSTRUCTION. CONTRACTOR WILL NEED

TO FIELD VERIFY THE LOCATION OF ALL EXISTING IRRIGATION

EQUIPMENT PRIOR OF CONSTRUCTION. THE USE OF A WIRE TRACER

REQUIRED. CONTRACTOR TO NOTIFY IRRIGATION CONSULTANT OR

GOLF COURSE SUPERINTENDENT IF THERE ARE ANY PROBLEMS PRIOR

TO CONSTRUCTION.

2. CONTRACTOR IS RESPONSIBLE TO KEEP ALL EXISTING IRRIGATION (TO

REMAIN) WITH WATER AT ALL TIMES DURING CONSTRUCTION. THIS

MAY INCLUDE PROVIDING TEMPORARY WATER SOURCE DURING

CONSTRUCTION.

C-12

C-11

B

B

C

L

I

N

C

O

L

W

Y

LA

LA

LA

fax 925.932.5671tel 925.939.3985 www.rmairrigation.com

2760 Camino Diablo Walnut Creek, CA 94597 t

Russell D. Mitchell Associates, Inc.

Irrigation Consultant:

IRRIGATION PLAN

TWO WIRE CABLE TO SPRINKLERS

I-3

1"=60'

CALL BEFORE YOU DIG

UNDERGROUND SERVICE ALERT

30' 120'60'0

SCALE:

fax 925.932.5671tel 925.939.3985 www.rmairrigation.com

2760 Camino Diablo Walnut Creek, CA 94597 t

Russell D. Mitchell Associates, Inc.

Irrigation Consultant:

IRRIGATION LEGEND AND NOTES

I-4

NONE

IRRIGATION LEGEND

SYMBOL NUMBER DESCRIPTION

QB44NP10 BUCKNER QUICK COUPLING VALVE

SH

LATERAL LINE/SUB MAINLINE: SCH 40 PLASTIC PIPE WITH LASCO

HEAVY TURF SURGE GUARD FITTINGS. ALL LATERAL LINES SHALL BE 2"

UNLESS NOTED OTHERWISE. PURPLE WITH RECYCLED WATER

LABELING

18" COVER.

APCO AIR VENT/VACUUM RELIEF VALVE 143C-1"

8411062PQ (2" VALVE)

C900 SADDLE MODEL #S

· 80491H (4")

HARCO DOUBLE STRAP SWIVEL SADDLE (C900) AND FULL PORT 316 SS

ANGLE VALVE WITH 2" SQUARE NUT WITH DI GRIP RING.

MAIN LINE: 4" AND LARGER:

C900 PSI RING-TITE PVC PLASTIC PIPE WITH DUCTILE IRON FITTINGS,

WITH MJ FITTINGS OR D.I. JOINT RESTRAINTS. COLOR: PURPLE WITH

RECYCLED WATER LABELING

30" COVER.

ALL PIPE SHALL BE PURPLE IN COLOR WITH LABELING

APPROVED FOR USE WITH RECYCLED WATER SYSTEMS.

NOTE:

A-2361-RWGV-4" MUELLER RESILIENT WEDGE (FLANGE X FLANGE) WITH SQUARE

OPERATING NUT GATE VALVE.

SPLICE/PULL BOX

NEW 1.5" SCH 40 PVC CONDUIT WITH REQUIRED SWEEPS. INSTALLA

PAIGE ELECTRICAL P7072D (12 GAUGE) WIRE - WITHIN CONDUIT.

(FROM SMART HUBS ROUTE ALONG MAIN LINE TO ISOLATION

VALVES OR REMOTE CONTROL VALVES)

WIRE COLOR SHALL BE RED.

INF34-336-6-7 TORO ROTARY POP-UP SPRINKLER-VALVE-IN-HEAD (FULL CIRCLE) WITH LYNX

SMART MODULE

INF35-316-6-7

INF35-346-6-7

INF35-316-6-7

TORO POP-UP GEAR DRIVEN ROTOR (TURF)T5-P-CK-E/3.0LA

PAIGE ELECTRICAL P7072D (14 GAUGE) WIRE - DIRECT BURY WITH PIPE - FEED

WIRE DOWN WIRE CHUTE OF PLOW WITH HDPE LATERAL LINE (ISOLATION

VALVES TO SPRINKLERS AND VALVES). COLOR ORANGE OR YELLOW.

1. IRRIGATION CONTROL WIRES: SOLID COPPER WITH U.L. APPROVAL FOR DIRECT BURIAL IN GROUND. SIZE #12AWG OR

#14AWG WIRE WITH A JACKETED 2-CONDUCTOR. PREFERRED WIRE MAKE AND MODEL IS PAIGE ELECTRIC MODEL NO.

P-7072D OR APPROVED EQUAL. USE AWG-#12 WITHIHN 1.5" CONDUIT TO ALL REMOTE CONTOL VALVES, ALONG THE

MAIN LINE TO ISOLATION VLAVE. USE #14 FROM ISOLATION VALVE TO SPRINKLERS OR APPROVED EQUAL. ROUTE ALONG

MAIN LINE AND LATERALS AS MUCH AS POSSIBLE.

2. GROUNDING SHALL BE PROVIDED EVERY EVERY 1000 FEET ALONG THE MAIN LINE , GROUND WITH A 5/8" X 8' COPPER

CLAD GROUNDING ROD AND GROUND PLATE. #6 COPPER WIRE TO SURGE DEVICE/DECODER. INCLUDE A SURGE ARRESTOR (TORO DEC-SG-LINE) AT EACH GROUNDING LOCATION. A CAD WELD CONNECTION TO BE USED TO CONNECT

THE SURGE DEVICE TO THE GROUND WIRE WITH A DBR/Y-6 OR WATERPROOF CONNECTOR. LOCATE THE GROUND ROD

IN THE ISOLATION VALVE BOX AND THE GROUND PLATE

3. AT LOCATIONS WHERE SURGE ARRESTORS ARE INSTALLED USE A 14"x19" PLASTIC VALVE BOXES.

4. SPLICING OF COMMUNICATION WIRE WILL NOT BE PERMITTED EXCEPT AT SPRINKLERS AND AT ISOLATION VALVES. LEAVE A 24" COIL OF EXCESS WIRE AT EACH SPLICE. WHERE SPLICING IS REQUIRED, BESIDES AT THE ISOLATION VALVES, LOCATE

IN A 10" DIAMETER ELECTRICAL BOX.

5. SMART HUB LOCATIONS ARE DIAGRAMMATIC. THE EXACT LOCATION WILL BE DETERMINED ON SITE PRIOR TO

INSTALLATION.

6. GROUNDING OF COMPUTER & SMART HUB EQUIPMENT SHALL BE IN COMPLIANCE WITH THE MANUFACTURERS RECOMMENDATIONS. PROVIDE AND INSTALL AN APC SMART UPS 1500VA AND AN INTERMATIC AG2401 POWER SURGE

ARRESTOR ON THE INCOMING POWER SUPPLY FROM THE EXISTING CONTROLLER.

11. INSTALL 3" DETECTABLE TAPE ABOVE ALL 4" AND 6" PRESSURIZED MAIN LINES AS DETAILED.

12. THE LOCATIONS OF THE AIR VENT/VACUUM RELIEF VALVES ARE APPROXIMATE, PRECISE LOCATIONS SHALL BE DETERMINED

ON SITE DURING IRRIGATION STAKING.

13. FIELD STAKING OF THE SPRINKLERS WILL BE COMPLETED IN THE FIELD BY THE IRRIGATION CONSULTANT. THE CONTRACTOR SHALL NOTIFY THE CONSULTANT A MINIMUM OF 3 DAYS PRIOR TO PROVIDING STAKING VISITS.

14. IRRIGATION PLANS ARE DIAGRAMMATIC. NO TRENCHING OR PLOWING OF WIRE OR PIPE WILL BE PERMITTED IN GREENS, TEES AND SAND TRAPS

15. ALL SPRINKLER HEADS SHALL BE SET PERPENDICULAR TO FINISH GRADE OF THE AREAS TO BE IRRIGATED

16. PRESSURE SETTINGS AT EACH VALVE IN HEAD SPRINKLER SHALL BE FACTORY SET AT 65 PSI.

17. CONTRACTOR SHALL REMOVE ALL EXISTING SPRINKLERS, QCV'S AND CONTROLLERS. DO NOT DAMAGE EQUIPMENT

DURING REMOVAL.

18. ISOLATION VALVES SHALL BE LOCATED NO CLOSER THAN FOUR FEET ON CENTER ALONG THE MAIN LINE AND A MINIMUM

OF FOUR FEET FROM THE PIPE ENDS.

19. INSTALL GREEN BOXES FOR ALL ISOLATION VALVES, BLACK BOXES FOR GATE VALVES AND GRAY BOXES FOR ELECTRICAL.

INSTALL RECYCLED WATER DECALS AND ID TAGS AS DETAILED.

20. WHERE IT IS NECESSARY TO EXCAVATE ADJACENT TO EXISTING TREES, USE CAUTION TO AVOID INJURY TO TREES AND TREE ROOTS. EXCAVATE BY HAND IN AREAS WHERE TWO (2) SPRINKLERS INCH AND LARGER ROOTS OCCUR. PAINT ROOTS ONE

(1) INCH AND LARGER IN DIAMETER WITH TWO COATS OF TREE SEAL, OR EQUAL. DO NOT TRENCH ACROSS ROOTS.

APPROACH THE TREE WITH A SINGLE LINE IN A RADIAL DIRECTION. ROUTE MAIN LINE AROUND TREES AS REQUIRED. OBTAIN

OWNERS APPROVAL OF MAIN LINE TRENCH ROUTE PRIOR TO TRENCHING.

IRRIGATION NOTES

P220GS-27-9-6 TORO 1.5" REMOTE CONTROL VALVE WITH PRESSURE REDUCING VALVE. SET TO

60 PSI.

TORO ROTARY POP-UP SPRINKLER-VALVE-IN-HEAD (FULL CIRCLE-SMALL RADIUS)

WITH LYNX SMART MODULE

TORO ROTARY POP-UP SPRINKLER-VALVE-IN-HEAD (PART CIRCLE) WITH LYNX

SMART MODULE

TORO ROTARY POP-UP SPRINKLER-VALVE-IN-HEAD (PART CIRCLE-SMALL RADIUS)

WITH LYNX SMART MODULE

LA DEC-SG-LINE

DEC-RSP-1000-DR TORO SMART HUB PEDESTAL MOUNTED AND

RADIO COMMUNICATION TO CENTRAL (GREEN

ENCLOSURE)

TORO LIGHTNING ARRESTOR WITH 8' GROUND

ROD ( #182000) AND PAIGE GROUNDING PLATE

(#182199IC)

B

LSM-1 TORO SMART MODULE. INSTALL WITHIN VALVE BOX AND WIRE TO

EXISTING VALVE. USE 3M-DBR6 WATERPROOF SPLICE KITS FOR ALL

SPLICES.

2760 Camino Diablo Walnut Creek, CA 94597 t

Russell D. Mitchell Associates, Inc.

Irrigation Consultant:

IRRIGATION DETAILS

I-5

NONE

SCALE: NONE

8 SMART HUB IN ENCLOSURE

1.5"

24" MIN.

12"

IRRIGATION SMART HUB-SET LEVEL 2-1.25" SCH 40 PVC CONDUITS 240

VOLT A.C. ELECTRICAL SERVICE FROM

SOURCE TO CONTROLLER AND

COMMUNICATION CABLE.

LOW VOLTAGE CONTROL WIRING.

CONCRETE PAD-6" THICK (MIN.) EXTEND

12" BEYOND EACH SIDE AND BACK, 24"

IN FRONT. PAD SHALL BE 1.5" ABOVE

FINISH GRADE.

FINISH GRADE.

4" SCH 40 GREY PVC ELECTRICAL

CONDUITS WITH SWEEP ELL FOR LOW

VOLTAGE WIRES. 18" BELOW GRADE.

1" PVC CONDUIT WITH SWEEP ELL FOR

GROUND WIRE.

24" MIN. AND OR 12" BEYOND

CONCRETE BASE.

6 6" ROUND BLACK PLASTIC BOX WITH

T-LID FOR GROUND ROD.

CADWELD CONNECTIONS7

CONTROLLER BOX MARKER DECAL

SHOWN AFFIXED TO BOX EXTERIOR

(PLACE TO INTERIOR OF BOX IF

POSSIBLE) T CHRISTY ENTERPRISES,

INC. MODEL 4100 OR EQUAL.

#6 AWG SOLID BARE COPPER WIRE -

INSTALL WITHOUT SHARP BENDS.

PROVIDE 12" COVER OVER WIRE.

8' LONG COPPER GROUND RODS

(PLACE 3 RODS IN A 16 FOOT

TRIANGULAR PATTERN) SEE

GROUNDING DETAIL

18" MIN.

SCALE: NONE

5 WEATHERPROOF WIRE SPLICE ASSEMBLY

INSTRUCTIONS:

1. STRIP WIRES APPROXIMATELY 1/2" FROM ENDS TO EXPOSE WIRE.

2. TWIST CONNECTOR AROUND WIRES CLOCKWISE UNTIL HAND TIGHT, DO NOT

OVERTIGHTEN.

3. INSERT WIRE ASSEMBLY TO BOTTOM OF GEL-FILLED TUBE. CHECK TO MAKE SURE

CONNECTOR HAS BEEN PUSHED PAST LOCKING FINGERS AND IS SEATED AT THE

BOTTOM OF THE TUBE.

4. PLACE WIRES WHICH EXIT TUBE IN WIRE EXIT HOLES AND CLOSE CAP UNTIL IT SNAPS.

5. INSPECT FINAL SPLICE ASSEMBLY THAT IT IS SECURED.

NOTE:

MAXIMUM # OF WIRES PER CONNECTOR:

· 3-#14 GAUGE

· 2-#12 GAUGE

STEP 5STEP 4

STEP 1

STEP 2

STEP 3

SCALE: NONE

4 TRENCHING

CLEAN BACKFILL MATERIAL.

FINISH GRADE.

LATERAL LINE (SUB-MAIN)

MAIN LINE.

COMMUNICATION CABLE FROM SMART HUB TO ISOLATION VALVES. INSTALL IN

1.25" CONDUIT BELOW SHOULDER OF PIPE.

NOTES:

1. REUSE SALVAGED EXCAVATED FILL AND COMPACT TO ORIGINAL DENSITY IN

LANDSCAPE AREAS. BACKFILL MATERIAL SHALL BE THE EARTH EXCAVATED

FROM THE TRENCHES, FREE FROM ROCKS (ANYTHING LARGER THAN 2"),

CONCRETE CHUNKS, AND OTHER FOREIGN OR COARSE MATERIALS.

4"

REFER TO

LEGEND

18"

SPLIT BOLT CONNECTORS. WRAP

WITH 6 THICKNESSES OF

ELECTRICAL TAPE AND PLACE

INTO SCOTCHCAST #4 SEAL

PACK. SIZE AS REQUIRED.

BRICK-ONE PER CORNER

SCHEDULE 40 U.L. LISTED PVC

CONDUIT

3/4" DRAIN ROCK-6" DEEP.

EXTEND 3" MIN BEYOND BRICKS

SCALE: NONE

TWO WIRE PULL BOX

FINISH GRADE1

1 9

SCHEDULE 40 PVC SWEEP ELLS6

7 SEAL CONDUIT OPENINGS WITH

WATERPROOF FOAM.

19 GAUGE S.S 1/2" SQUARE

WIRE MESH. WRAP UP SIDES OF

BOX.

GREY RECTANGULAR PLASTIC

BOX WITH T-LID. (BOLT DOWN)

14" x 19" x 12" DEEP. MARK

COVER: "ELECTRICAL".

Controller Unit for Recycled Water

Unidad Controladora del Agua Recuperada

CONTROLLER BOX MARKER DECAL SHOWN AFFIXED

TO BOX EXTERIOR (PLACE TO INTERIOR OF BOX IF

POSSIBLE) T CHRISTY ENTERPRISES, INC. MODEL 4100

OR EQUAL.

ATTENTION

ATENCION

TWO WIRE CABLE (DIRECT BURY)4

3" DETECTABLE WARNING TAPE OVER MAIN LINE. INSTALL 3" ABOVE MAIN LINE.

USE CHRISTY MODEL #TA-DT-3-PRW FOR RECYCLED IRRIGATION WATER SYSTEMS

PURPLE ID DECAL DRILLED INTO

THE LID

SCALE: NONE

3" MIN.

3" MIN.

PEA GRAVEL OR 3/4" DRAIN ROCK

FINISH GRADE

BRICK-2 TOTAL

1 6

LEEMCO LMJD-SERIES (PIPE TO

VALVE) RESTRAINT OR EQUAL.

ONE EACH SIDE OF VALVE

8" C900 OR SCHEDULE 40 PVC PIPE (NOTCH

TO FIT OVER MAIN LINE PIPE)

FLANGED END GATE VALVE W/ 2" SQUARE

AWWA OPERATING NUT SEE LEGEND FOR

SPECS.

C900 PVC MAIN LINE8

FLANGE GATE VALVE - 4" AND LARGER (C900)

NOTE:

SUPPORT VALVE WITH

2" x 4" REDWOOD

STAKES AS REQUIRED

FINISH GRADE

SCALE: NONE

AIR RELIEF VALVE3

1" BRASS BALL VALVE5

12" CONCRETE PAVER SUPPORT BLOCK

10 PEA GRAVEL OR 3/4" DRAIN ROCK- 4" DEEP

BELOW VALVE (NO SOIL IN VALVE BOX).

MAIN LINE AIR RELIEF VALVE

1 2

14 16

1" BRASS NIPPLE (3" IN LENGTH) 2

TOTAL.

1" BRASS NIPPLE (4" IN LENGTH)6

1" THREADED 90°7

9 BRICK SUPPORT. (4 TOTAL/ 1 @ EA

CORNER).

11 C900 GASKETED PVC MAIN LINE

12 1" BRASS NIPPLE (LENGTH AS REQUIRED

DEPENDING ON MAIN LINE DEPTH). USE BRASS

REDUCER BUSING AT TAPPED TEE.

13 C900 DUCTILE IRON DOUBLE STRAPPED SADDLE

WITH 2" THREADED OUTLET. HARCO MODEL

80490H4 (4"), 80690H4 (6"), 80890H4 (8").

1" BRASS CAP15

16 1" BRASS NIPPLE (LENGTH AS REQUIRED

DEPENDING ON MAIN LINE DEPTH)

INSTALLATION INSTRUCTIONS:

1. LUBRICATE THE GASKET IN THE MATING FEMALE SWIVEL JOINT AND THE INLET SPIGOT OF

THE VALVE WITH PVC PIPE LUBRICANT.

2. ROTATE MALE THREAD "IN" UNTIL JOINT BOTTOMS OUT."

3. ROTATE MALE THREAD "OUT" TO PROPER HORIZONTAL ORIENTATION FOR VALVE UP TO

AND NO MORE THAN 360°.

4. INSTALL BEVEL PIPE IN OUTLET BELL AFTER LUBRICATING OUTLET GASKET AND PIPE END.

REMOVE WOOD WEDGE AND TIGHTEN RESTRAINT BOLT TO 35 FT-LBS.

+-18"

14"

4 9

SCALE: NONE

ANGLE ISOLATION VALVE3

3/4" DRAIN ROCK 6" DEEP

FINISH GRADE

2" SCH 40 PVC PUPLE PIPE TO SPRINKLERS.

USE 2" x 3" SCH 80 REDUCER TO INCREASE

TO 3" FOR GREENS LOOP.

BRICK - 2 TOTAL

FEMALE SWIVEL SADDLE FOR DIPS, HARCO

MODEL 80491H (4"), 80691H (6")

PURPLE C900 PVC MAIN LINE

1 2"x6" GASKET BY MALE SWIVEL S.S.

LATERAL ISOLATION VALVE. HARCO

MODEL 8411062PQ.

PURPLE RECYCLED WATER WARNING TAG10

CARSON 1730 -15" DEPTH BOX.

PURPLE RECYCLED WATER WARNING TAG.

REFER TO

IRRIGATION

LEGEND

1" BRASS THREADED TEE17

18 GAUGE 1/2" SQUARE STAINLESS

STEEL WIRE MESH. WRAP UP SIDES

OF THE BOX. ANCHOR TO BOX

WITH S.S. SCREWS AND WASHER

AS REQUIRED.

3"

LOCATE COMMON GROUND WIRE

SPLICES BETWEEN VALVE BOX AND SLEEVE

10" ROUND GREEN LID AND VALVE BOX

WITH RECYCLED WATER DECAL INSTALLED

ON LID

6" FLEXIBLE DRAIN PIPE - EXTEND BELOW

BOTTOM OF VALVE

PURPLE RECYCLED WATER WARNING

TAG. DRILL A HOLE INTO SLEEVE.

ATTACHED WITH S.S. ZIP TIE.

10" ROUND GREEN LID AND VALVE BOX WITH

RECYCLED WATER DECAL INSTALLED ON LID

PURPLE ID DECAL DRILLED INTO

THE LID

PURPLE ID DECAL DRILLED INTO THE LID19

SCALE: NONE

6 THRUST BLOCK

1 1/4° BEND REDUCER END CAP

22 1/2°

OR 45° BENDWYETEE

TEE W/ STUB 90° BENDCROSS

CONCRETE THRUST BLOCK SHALL HAVE CONTACT WITH FITTING ONLY AND REMAIN CLEAR

OF PIPE AND JOINTS.

THRUST BLOCK TO BE CONSTRUCTED OF 3000 PSI CONCRETE.

BLOCK TO BE POURED AGAINST UNDISTURBED SOIL.

1.

2.

3.

SCALE: NONE

THRUST BLOCK INSTALLATION7

14"x14"

L

A

1.2.93

45° BEND

12"x12"16"x16"

90° BEND

1.7

NOTES:

DISTANCE "A" TO BE 18" MINIMUM FROM FITTING TO UNDISTURBED SOIL. THRUST BLOCKS

SHALL BE POURED ONLY AGAINST UNDISTURBED EARTH.

REFER TO THRUST BLOCK CHART FOR DISTANCE "L" AND "H".

CONCRETE TO BE SHAPED INTO A WEDGE WITH THE WIDE END AGAINST THE SOLID WALL

OF THE TRENCH.

CONCRETE SHALL BE KEPT BEHIND THE BELL OF THE FITTING WITH THE CONCRETE NOT

PERMITTED TO RUN OVER AGAINST THE PIPE OR ONTO THE JOINT.

THE FIGURES IN THIS CHART ARE BASED ON A WORKING PRESSURE OF 150 PSI.

1.

2.

3.

THRUST BLOCKING APPLIES TO 4" AND LARGER PIPE ONLY.4.

5.

L x H L x H L x H

BEARING

AREA

(SQUARE FT.)

4"

TEES,DEADENDS &VALVES

H (MAX. 3' [1m])

PIPE SIZE

BEARING

AREA

(SQUARE FT.)

BEARING

AREA

(SQUARE FT.)

SCALE: NONE

SMART HUB GROUNDING DETAIL9

2760 Camino Diablo Walnut Creek, CA 94597 t

Russell D. Mitchell Associates, Inc.

Irrigation Consultant:

IRRIGATION DETAILS

I-6

NONE

FINISH GRADE1

SCH 40 PVC LATERAL LINE

NOTE:

INSTALL UNI-BODY

NIPPLE ON RISER

ASSEMBLY 30° UP

FROM HORIZONTAL.

VALVE-IN-HEAD SPRINKLER (PURPLE

MARKING) SET FLUSH WITH FINISH

GRADE AT THE TIME OF INSTALLATION.

LOCATE ALL SPLICES WITHIN INFINITY

SPRINKLER COMPARTMENT. USE

3M-DBR6 WATERPROOF SPLICE KITS

FOR ALL SPLICES.

SCALE: NONE

1 TORO INFINITY SPRINKLER RISER

18"

REMOTE CONTROL VALVE

SCALE: NONE

3" MIN 6" MAX

REMOTE CONTROL VALVE WITH FLOW

CONTROL AND MANUAL BLEED AND

PRESSURE REGULATOR

SCH 40 PVC SUB MAIN LINE

PEA GRAVEL- 4" DEEP BELOW VALVE

(NO SOIL IN VALVE BOX)

PROVIDE 3M-DBY SEAL PACKS AT

ALL SPLICES AND 36" OF EXCESS

WIRE IN VALVE BOX.

REFER TO IRRIGATION LEGEND

BRICK-1 EACH CORNER

19 GAUGE 1/2" SQUARE WIRE

MESH. WRAP UP SIDES OF BOX.

FINISH GRADE

7 8

RECTANGULAR PLASTIC VALVE BOX

WITH BOLT DOWN LID. INSTALL BOX

AS SHOWN IN BOX INSTALLATION

DETAIL. TOP DIMENSION: 11 3/4" X

17" (12" DEEP)

LATERAL LINE TO SPRINKLERS

FRONT

WARNING

NO TOMAR

AGUA IMPURA

AVISO

SCALE: NONE

IDENTIFICATION OF RECYCLED WATER

WARNING TAG

BACK

SAMPLE WARNING TAG. BACKGROUND PURPLE

(PANTONE 512) WITH BLACK LETTERING.

RECYCLED WATER

DO NOT DRINK

SCALE: NONE

IRRIGATION BOX COVER/LIDS WITH WARNING

SIGN

REFERENCE: T. CHRISTY ENTERPRISES, INC.

CATALOG PART NO. 3800 OR EQUAL

PURPLE ID DECAL DRILLED INTO THE

LID FOR RECYCLED SYSTEMS.

PURPLE ID DECAL DRILLED INTO

THE LID FOR RECYCLED

SYSTEMS.

PURPLE ID DECAL DRILLED INTO

THE LID

PURPLE RECYCLED WATER WARNING

TAG. ATTACHED WITH S.S. ZIP TIE.

RECYCLED WATER

DO NOT DRINK-NO TOMAR

RECYCLED WATER

INSTALLATION NOTES:

1. ACME O-RING SEALED THREADS ARE TO BE FINGER TIGHTENED AND "BACKED OFF"

ONE FULL ROTATION BEFORE INSTALLATION.

2. THE SWING JOINT LAY ARM IS TO BE INSTALLED AT AN ANGLE BETWEEN 30° AND

45°.

SCALE: NONE

3 QUICK COUPLING VALVE

SIDE VIEW

7" ROUND PLASTIC VALVE BOX

WITH BOLT DOWN LID

QUICK COUPLING VALVE WITH PURPLE TOP.

FINISH GRADE

BRICK - 2 TOTAL.

PEA GRAVEL- 4" DEEP BELOW VALVE (NO

SOIL IN VALVE BOX).

FOR 1" Q.C.V. USE LASCO 1" SWING

JOINT, 1

2" ACME INLET X 1" SNAP-LOC

BRASS MIPT OUTLET, MODEL

#G1MS-218. FOR 11

2" Q.C.V., USE LASCO

2" SWING JOINT, 11

2" ACME INLET X

2" SNAP-LOC BRASS MIPT OUTLET,

MODEL #G3MS-218.

2"

1 2

1" SCH 40 PVC PIPE STABLIZER. 12" LENGTH4

2-#4 REBAR. 24" IN LENGTH5

SUB MAIN LINE6

LASCO HEAVY TURF 2" SERVICE TEE

WITH A 1.5" ACME OUTLET

(SxSxACME) LASCO MODEL #302251

LASCO JOINT WITH MALE ACME THREADS.

315 PSI RATED MODEL #G1M0-212 (1.5"

ACME INLET TO 1" ACME OUTLET INTO

SPRINKLER). ADJUST ANGLE OF SWING

JOINT LAY ARM BETWEEN 30° TO 45° TO

ALLOW ADEQUATE IMPACT ABSORPTION.

DO NOT USE TEFLON TAPE OR PIPE DOPE

WITH ACME THREADS.

SCH 80 TOE NIPPLE

LASCO HEAVY TURF SURGE GUARD PVC

90° ELBOW

(SXS)

SCHEDULE 40 PVC PIPE

LASCO HEAVY TURF SURGE GUARD

PVC TEE

LASCO HEAVY TURF 2" SERVICE TEE WITH

A 1.5" ACME OUTLET (SxSxACME) LASCO

MODEL #302251

SCALE: NONE

4 POP-UP ROTARY SPRINKLER - NON-VIH

TOP VIEW

SIDE VIEW

PVC LATERAL LINE.

POP-UP ROTARY SPRINKLER.

FINISH GRADE.

REFER TO

IRRIGATION

LEGEND

LASCO HEAVY TURF SURGE GUARD

PVC TEE OR ELBOW WITH THREADED

OUTLET.

UNITIZED SWING JOINT: 3/4"-LASCO

MODEL T732-212

1"-LASCO MODEL T932-212.

SCALE: NONE

GROUNDING OF COMMUNICATION CABLE5

TWO WIRE

CABLE FROM

SPLICE IN

ISOLATION

VALVE BOX

TWO WIRE

CABLE TO

NEXT

SPRINKLER

OR VALVE

2760 Camino Diablo Walnut Creek, CA 94597 t

Russell D. Mitchell Associates, Inc.

Irrigation Consultant:

IRRIGATION DETAILS

I-7

NONE

3. MAIN /LATERAL SEPARATION STANDARDS

SCALE: NONE

REQUIREMENTS FOR HORIZONTAL AND VERTICAL PIPELINE SEPARATION1

* 12" MIN VERTICAL SEPARATION REQUIREMENT

* CASING REQUIRED IF VERTICAL SEPARATION

REQUIREMENT NOT MET

* 48" MIN HORIZONTAL SEPARATION

REQUIREMENT

POTABLE WATER

SLEEVE**

POTABLE WATER

SLEEVE**

SANITARY SEWER

RECYCLED WATER

SLEEVE**

CROSSING #1

CROSSING #2

* 12" MIN VERTICAL SEPARATION

REQUIREMENT

* 12" MIN VERTICAL SEPARATION

REQUIREMENT

* SLEEVE RW PIPELINE 5 FEET FROM

CENTERLINE OF PW PIPELINE

* NO JOINTS FOR EIGHT FEET ON

EITHER SIDE OF POTABLE WATER

CROSSING

1. PARALLEL SEPARATION

STANDARDS

POTABLE WATER

STORM DRAINS OR

SANITARY SEWER

SLEEVE**

2. CROSSING SEPARATION STANDARDS

SITUATION CRITERIA

PARALLEL

RECYCLED WATER

RECYCLED WATER

CRITERIA

RECYCLED

WATER

SANITARY SEWER

BASIC SEPARATION STANDARDS:

1. POTABLE AND RECYCLED PIPELINES SHALL NOT TO BE INSTALLED IN THE SAME TRENCH.

RECYCLED PIPELINES SHALL BE DESIGNED TO BE INSTALLED BELOW THE POTABLE

PIPELINES WHERE THE TWO PIPELINES RUN PARALLEL TO EACH OTHER. WHERE THIS IS

NOT POSSIBLE, THE RECYCLED PIPELINE SHALL BE INSTALLED IN A CASING. DETAILS OF

THIS INSTALLATION SHALL BE CLEARLY SHOWN ON THE PLANS.

2. PARALLEL CONSTRUCTION

A. THE HORIZONTAL SEPARATION BETWEEN ONSITE RECYCLED AND POTABLE LINES

SHALL BE A MINIMUM OF FORTY-EIGHT (48) INCHES, MEASURED BETWEEN

OUTSIDE DIAMETERS. (SEE DETAIL 1)

3. CROSSING CONSTRUCTION

A. IN GENERAL, ONSITE RECYCLED WATER LINES SHALL BE INSTALLED BELOW

POTABLE WATER LINES, WITH A MINIMUM VERTICAL SEPARATION OF TWELVE

(12) INCHES, MEASURED BETWEEN OUTSIDE DIAMETERS. (SEE DETAIL 2

CROSSING #1) EXCEPTIONS TO THIS GENERAL REQUIREMENT ARE AS

FOLLOWS:

i. RECYCLED WATER LINES MAY BE INSTALLED ABOVE POTABLE WATER

LINES WHERE THE RECYCLED LINES (LATERALS) ARE INTERMITTENTLY

PRESSURIZED. NO SPECIAL CONSTRUCTION REQUIREMENTS ARE

NECESSARY, PROVIDED THE TWELVE (12) INCHES VERTICAL

SEPARATION IS MAINTAINED.

ii. CONSTANTLY PRESSURIZED RECYCLED WATER LINES MAY BE INSTALLED

ABOVE POTABLE WATER LINES PROVIDING THE RECYCLED PRESSURED

LINE HAS AN AUTOMATIC FLOW CONTROL/SHUT-OFF DEVICE

INSTALLED, OR THE RECYCLED LINE IS SLEEVED. AN AUTOMATIC FLOW

CONTROL/SHUT-OFF DEVICE SHALL TERMINATE ALL FLOW TO A

LATERAL AUTOMATICALLY SHOULD THE FLOW EXCEED A PRESET

MAXIMUM GPM. SLEEVING SHALL EXTEND FIVE (5) FEET EACH SIDE

FROM THE CENTER-LINE OF THE POTABLE LINE, FOR A TOTAL LENGTH

OF TEN (10) FEET . THE SLEEVE SHALL BE PURPLE PVC. IN ALL CASES,

THE TWELVE (12) INCHES VERTICAL SEPARATION SHALL BE

MAINTAINED. (SEE DETAIL 2 CROSSING #2)

B. WHEN CROSSING A POTABLE WATER MAIN THE CROSSING SHOULD BE AS

CLOSE AS PRACTICAL TO THE PERPENDICULAR AND NO LESS THAN 45 DEGREES.

4. RECYCLED WATER FACILITIES (ONSITE) SHALL BE DESIGNED/INSTALLED TO THE

FOLLOWING MINIMUM TOP OF PIPE DEPTH REQUIREMENTS:

A. INTERMITTENT PRESSURE LINES TWO (2) INCHES AND SMALLER: TWELVE (12)

INCHES.

B. CONSTANT PRESSURE LINES SMALLER THAN SIX (6) INCHES: EIGHTEEN (18)

INCHES.

C. CONSTANT PRESSURE LINES SIX (6) INCHES AND LARGER: THIRTY (30) INCHES.

GENERAL NOTES

1. PROPER CORROSION PROTECTION TO PIPELINES IS REQUIRED

WHICH INCLUDES BUT IS NOT LIMITED TO OUTSIDE COATING, INSIDE

LINING, DIELECTRIC TREATMENT, AND OTHER CATHODIC PROTECTION.

2. STANDARD SPECIFICATION ARE DETAILED IN THE NMWD STANDARD

SPECIFICATION SECTION 15152 - RECYCLED WATER FACILITIES

(ONSITE), ANY EXCEPTIONS TO THESE REQUIREMENTS REQUIRE A

SPECIAL REVIEW BY NMWD AND APPROVAL SHALL BE GRANTED BY

THE CALIFORNIA DEPARTMENT OF PUBLIC HEALTH.

SCALE: NONE

BASIC SEPARATION STANDARD NOTES

SCALE: NONE

BASIC SEPARATION STANDARD NOTES

CONTINUE

#14AWG TWO WIRE CABLE FROM SMART

HUB.

LYNX SMART MODULE

TWO WIRE CABLE TO NEXT DECODER

ALL DECODERS SHALL BE ADDRESSED AND INPUTTED INTO CENTRAL

COMPUTER.

NOTE:

1.

8 EXISTING VALVE BOX.

9 EXISTING REMOTE CONTROL VALVE.

3M DBR/Y-6 OR APPROVED EQUAL

WATERPROOF SPLICE KIT (4 TOTAL)

LYNX SMART MODULE WIRING

SCALE: NONE

DECODER

USE U.F. SAFETY CABLE STRIPPER BY KING INNOVATION (MODEL

NUMBER 46200) FOR ALL TWO-WIRE SPLICE CONNECTIONS.

2.

A MAXIMUM OF 4" OF WIRE SHALL BE

STRIPPED FROM TWO WIRE CABLE WHEN

SPLICING AT DECODERS.

CONNECT CORRECT DECODER WIRES

TO VALVE SOLENOID WIRES

5 CONNECT CORRECT DECODER WIRES TO

TWO WIRE CABLES.

Sheets and Views
Lincoln_Park_GC_Irrigation_Design-I-1
Lincoln_Park_GC_Irrigation_Design-I-2
Lincoln_Park_GC_Irrigation_Design-I-3
Lincoln_Park_GC_Irrigation_LND-I-4
Lincoln_Park_GC_Irrigation_LND-I-5
Lincoln_Park_GC_Irrigation_LND-I-6
Lincoln_Park_GC_Irrigation_LND-I-7

File details come from the government source that posted it. Updated .