Attachment_1_Lincoln_Park_GC_IrrigationDesign.pdf
PDF 4 MB Posted
- Solicitation number
- SFGOV-0000012108
- Issued by
- San Francisco County, San Francisco City, California
About this file
This is an irrigation design attachment for the City and County of San Francisco Recreation and Park Department related to a Micro LBE Set-Aside solicitation for irrigation work at Lincoln Park Golf Course. The project encompasses automation and renovation of the irrigation system for Holes 1, 13, 17, and 18 at the golf course located at 300 34th Ave, San Francisco, CA 94121. Work includes furnishing and installing 1.5" Schedule 40 electrical conduit for two-wire cable, extending conduit and cable to existing remote control valves, installing new valve boxes, furnishing and installing Toro Lynx Smart Module Decoders, replacing existing Hunter ACC controllers with Toro Smart Hubs, and renovating irrigation infrastructure including new sprinkler installations, main line connections, and isolation valves. The design plans detail specifications for C900 PVC plastic pipe ranging from 2" to 6" in diameter, Toro rotary pop-up sprinklers with valve-in-head and smart module integration, grounding requirements with copper rods and surge arrestors, and comprehensive electrical and communication wiring installations. A non-mandatory pre-bid meeting is scheduled for Tuesday, October 6, 2026 at 10:00 AM at Lincoln Golf Course, with bids due no later than Tuesday, October 20, 2026 by 2:30 PM, submitted via email to bridget.webster@sfgov.org.
The project cost estimate is $408,000 and requires contractors to hold either an A or C-27 license. This is a Micro Local Business Enterprise (LBE) Set-Aside solicitation, restricting bidding eligibility to certified Micro LBE firms. The design documentation includes detailed irrigation plans, system upgrade specifications, and technical installation requirements for recycled water systems, including mandatory recycled water labeling, warning tags, and color-coded piping (purple). Contractor responsibilities include field verification of all existing irrigation equipment locations prior to construction, maintaining water supply to existing irrigation systems during construction, hand excavation in areas adjacent to trees, proper grounding of all electrical equipment in compliance with manufacturer specifications, and completion of field staking of sprinklers with minimum three-day notice to the irrigation consultant.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
CITY AND COUNTY OF SAN FRANCISCO
RECREATION AND PARK DEPARTMENT ADMINISTRATION
ATTACHMENT 1
See Next Page
CONTROLLER "S"
CONTROLLER "13"
13GR1
S
M
2" WM (#23115135)
2.5" 2.5"
2.5"
13FW3
13FW1
18FW1
18FW2
18FW3
13FW2
19GR1
1TE1
1FW2
M
A
N
J
M
A
N
G
M
A
N
G
M
A
N
G
C
C
M
A
N
F
M
A
N
H
M
A
N
H
M
A
N
K
M
A
N
K
M
A
N
K
M
A
N
E
M
A
N
E
M
A
N
E
M
A
N
E
MAN-D
M
A
N
D
C
C
M
A
N
M
M
A
N
M
M
A
N
M
M
A
N
L
M
A
N
N
C
M
A
N
L
M
A
N
H
M
A
N
H
M
A
N
G
M
A
N
L
L
E
G
I
O
N
F
H
N
R
D
R
I
V
E
CLEMENT STREET
CALIFORNIA
STREET
MARVEL CT
r d
A
V E
PG
C
L
U
B
H
O
U
S
E
B
B
B
B
1FW1
18GR1
LA
LA
PLAN NOTES NOTES:
1 FURNISH & INSTALL 1.5" SCH 40 ELECTRICAL CONDUIT FOR 2/C #14 AWG CABLE AS DETAILED
(TYPICAL)
2 EXTEND NEW CONDUIT AND 2/C #14 AWG CABLE TO EXISTING REMOTE CONTROL VALVES.
INSTALL NEW VALVE BOX ON EXISTING REMOTE CONTROL VALVE AS DETAILED. FURNISH & INSTALL TORO LYNX SMART MODULE DECODER TO EACH EXISTING REMOTE CONTROL VALVE AS DETAILED.
CONNECT 2/C #14 AWG CABLE TO LYNX SMART MODULE AS DETAILED. (TYPICAL)
3 EXTEND NEW CONDUIT AND 2/C #14 AWG CABLE TO EXISTING REMOTE CONTROL VALVES.
INSTALL NEW VALVE BOX ON EXISTING REMOTE CONTROL VALVE AS DETAILED. FURNISH &
INSTALL TORO LYNX SMART MODULE DECODER TO EACH EXISTING REMOTE CONTROL
VALVE AS DETAILED. CONNECT 2/C #14 AWG CABLE TO LYNX SMART MODULE AS DETAILED.
(TYPICAL)
MATCHLINE SEE SHEET I-2
APPROXIMATE LOCATION
OF A 30 x 40 STAGING
AREA FOR LINCOLN PARK
fax 925.932.5671tel 925.939.3985 www.rmairrigation.com
2760 Camino Diablo Walnut Creek, CA 94597 t
Russell D. Mitchell Associates, Inc.
Irrigation Consultant:
IRRIGATION PLAN
AUTOMATION OF HOLES 1, 13, & 18
I-1
1"=60'
CALL BEFORE YOU DIG
UNDERGROUND SERVICE ALERT
30' 120'60'0
SCALE:
EXISTING IRRIGATION NOTES:
1. ALL EXISTING IRRIGATION SHOWN IN GREY IS EXISTING AND SHALL REMAIN IN SERVICE. USE CAUTION
WHEN GRADING OR TRENCHING NEAR EXISTING IRRIGATION. EXACT ROUTING OF IRRIGATION
MAINLINE, WIRES, LOCATION OF SPRINKLERS/VALVE SHOULD BE INVESTIGATED PRIOR TO
CONSTRUCTION. CONTRACTOR WILL NEED TO FIELD VERIFY THE LOCATION OF ALL EXISTING
IRRIGATION EQUIPMENT PRIOR OF CONSTRUCTION. THE USE OF A WIRE TRACER REQUIRED.
CONTRACTOR TO NOTIFY IRRIGATION CONSULTANT OR GOLF COURSE SUPERINTENDENT IF THERE
ARE ANY PROBLEMS PRIOR TO CONSTRUCTION.
2. CONTRACTOR IS RESPONSIBLE TO KEEP ALL EXISTING IRRIGATION (TO REMAIN) WITH WATER AT ALL TIMES DURING CONSTRUCTION. THIS MAY INCLUDE PROVIDING TEMPORARY WATER SOURCE DURING
CONSTRUCTION.
CONTROLLER "C"
C
C-13
C-14
C-15
C-10
C-8
C-9
C-4
C-3
C-1
C-16
C-18
C-6
C-5
C-2
B-8
C-12
C-11
4"
4"
4"
LOCATION OF MAIN
LINE CONNECTION
TO GOLF COURSE
LOCATED IN FIELD.
CONNECTION TO
GOLF COURSE IS
LOCATED IN FIELD.
B
B
18TE1
16RO1
2"
2"
2"
2"
2"
2"
2"
2"
2"
2"
2"
2"
2"
2"
2"
2"
2"
2"
2"
2"
2"
3"
2"
2"
2"
2"
2"
2"
2"
2"
M
A
N
C
M
A
N
C
M
A
N
B
M
A
N
B
M
A
N
B
M
A
N
A
M
A
N
A
C
C
B
A
T
B
A
T
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C-3
C
C
C
C
C
C
C
C
C
C
C
C
C
C
M
A
N
M
M
A
N
C
C
C
C
C
B
B
C
C
B
C
C
C
B
B
C
M
A
N
B
M
A
N
B
B
B
L
I
N
C
O
L
W
Y
LIN
C
O
LN
H W
Y
B
B
LA
LA
LA
LA
LA
LA
APPROXIMATE LOCATION OF EXISTING 6"
TRANSITE MAIN LINE. POT HOLE AND LOCATE IN
FIELD. GOLF COURSE STAFF WILL ASSIST IN
LOCATING THE PIPE. CONNECT NEW MAIN LINE
TO EXISTING ASBESTOS CEMENT PIPE WITH A
ROMAC STYLE 501 LONG BARREL REPAIR
COUPLING OR APPROVED EQUAL. ASSUMED SIZE
OF EXISTING A/C PIPE IS 6". EXPOSE AND
MEASURE PRIOR TO ORDERING COUPLING.
SAWCUT EXISTING ROAD A MINIMUM OF 10' FROM NEWLY
INSTALLED IMPROVEMENTS. INSTALL 2-1.5" SCH 40
ELECTRICAL CONDUITS (1 SPARE & 1 FOR TWO WIRE
CABLE) WITHIN TRENCH ACROSS ROADWAY. REPAIR
SAWCUT AS REQUIRED TO MATCH EXISTING ROAD BASE
AND PAVING PROFILE. EXACT LOCATION OF SAWCUT SHALL
BE APPROVED BY CITY REPRESENTATIVE.
MATCHLINE SEE SHEET I-1
SYSTEM UPGRADE/SHEET SPECIFIC RETROFIT
MODIFICATION KEYNOTES:
1 REPLACE EXISTING HUNTER ACC 2-WIRE CONTROLLER
WITH TORO SMART HUB. CONNECT EXISTING TWO
WIRE THAT WAS ROUTED FROM EXISTING
CONTROLLER INTO SMART HUB. ROUTE NEW 1.25"
CONDUIT AND TWO WIRE CABLE OF A DIFFERENT
COLOR TO SERVICE EXISTING REMOTE CONTROL
VALVES AND NEW SPRINKLERS ON HOLE #17.
2 FURNISH & INSTALL 1.5" SCH 40 ELECTRICAL CONDUIT
FOR 2/C #14 AWG CABLE AS DETAILED (TYPICAL)
3 EXTEND NEW CONDUIT AND 2/C #14 AWG CABLE TO
EXISTING REMOTE CONTROL VALVES. INSTALL NEW
VALVE BOX ON EXISTING REMOTE CONTROL VALVE AS
DETAILED. FURNISH & INSTALL TORO LYNX SMART
MODULE DECODER TO EACH EXISTING REMOTE
CONTROL VALVE AS DETAILED. CONNECT 2/C #14 AWG
CABLE TO LYNX SMART MODULE AS DETAILED.
(TYPICAL)
4 REMOVE EXISTING QUICK COUPLERS ONCE NEW
SYSTEM IS OPERATIONAL. FILL VOIDS WITH TOP SOIL.
(TYPICAL ON HOLE #17)
5 FURNISH & INSTALL TORO LYNX SMART MODULE
DECODER TO EACH EXISTING REMOTE CONTROL
VALVE AS DETAILED (TYPICAL)
fax 925.932.5671tel 925.939.3985 www.rmairrigation.com
2760 Camino Diablo Walnut Creek, CA 94597 t
Russell D. Mitchell Associates, Inc.
Irrigation Consultant:
IRRIGATION PLAN
HOLE 17 RENOVATION
I-2
1"=60'
CALL BEFORE YOU DIG
UNDERGROUND SERVICE ALERT
30' 120'60'0
SCALE:
EXISTING IRRIGATION NOTES:
1. ALL EXISTING IRRIGATION SHOWN IN GREY IS EXISTING AND SHALL
REMAIN IN SERVICE. USE CAUTION WHEN GRADING OR TRENCHING
NEAR EXISTING IRRIGATION. EXACT ROUTING OF IRRIGATION
MAINLINE, WIRES, LOCATION OF SPRINKLERS/VALVE SHOULD BE
INVESTIGATED PRIOR TO CONSTRUCTION. CONTRACTOR WILL NEED
TO FIELD VERIFY THE LOCATION OF ALL EXISTING IRRIGATION
EQUIPMENT PRIOR OF CONSTRUCTION. THE USE OF A WIRE TRACER
REQUIRED. CONTRACTOR TO NOTIFY IRRIGATION CONSULTANT OR
GOLF COURSE SUPERINTENDENT IF THERE ARE ANY PROBLEMS PRIOR
TO CONSTRUCTION.
2. CONTRACTOR IS RESPONSIBLE TO KEEP ALL EXISTING IRRIGATION (TO
REMAIN) WITH WATER AT ALL TIMES DURING CONSTRUCTION. THIS
MAY INCLUDE PROVIDING TEMPORARY WATER SOURCE DURING
CONSTRUCTION.
C-12
C-11
B
B
C
L
I
N
C
O
L
W
Y
LA
LA
LA
fax 925.932.5671tel 925.939.3985 www.rmairrigation.com
2760 Camino Diablo Walnut Creek, CA 94597 t
Russell D. Mitchell Associates, Inc.
Irrigation Consultant:
IRRIGATION PLAN
TWO WIRE CABLE TO SPRINKLERS
I-3
1"=60'
CALL BEFORE YOU DIG
UNDERGROUND SERVICE ALERT
30' 120'60'0
SCALE:
fax 925.932.5671tel 925.939.3985 www.rmairrigation.com
2760 Camino Diablo Walnut Creek, CA 94597 t
Russell D. Mitchell Associates, Inc.
Irrigation Consultant:
IRRIGATION LEGEND AND NOTES
I-4
NONE
IRRIGATION LEGEND
SYMBOL NUMBER DESCRIPTION
QB44NP10 BUCKNER QUICK COUPLING VALVE
SH
LATERAL LINE/SUB MAINLINE: SCH 40 PLASTIC PIPE WITH LASCO
HEAVY TURF SURGE GUARD FITTINGS. ALL LATERAL LINES SHALL BE 2"
UNLESS NOTED OTHERWISE. PURPLE WITH RECYCLED WATER
LABELING
18" COVER.
APCO AIR VENT/VACUUM RELIEF VALVE 143C-1"
8411062PQ (2" VALVE)
C900 SADDLE MODEL #S
· 80491H (4")
HARCO DOUBLE STRAP SWIVEL SADDLE (C900) AND FULL PORT 316 SS
ANGLE VALVE WITH 2" SQUARE NUT WITH DI GRIP RING.
MAIN LINE: 4" AND LARGER:
C900 PSI RING-TITE PVC PLASTIC PIPE WITH DUCTILE IRON FITTINGS,
WITH MJ FITTINGS OR D.I. JOINT RESTRAINTS. COLOR: PURPLE WITH
RECYCLED WATER LABELING
30" COVER.
ALL PIPE SHALL BE PURPLE IN COLOR WITH LABELING
APPROVED FOR USE WITH RECYCLED WATER SYSTEMS.
NOTE:
A-2361-RWGV-4" MUELLER RESILIENT WEDGE (FLANGE X FLANGE) WITH SQUARE
OPERATING NUT GATE VALVE.
SPLICE/PULL BOX
NEW 1.5" SCH 40 PVC CONDUIT WITH REQUIRED SWEEPS. INSTALLA
PAIGE ELECTRICAL P7072D (12 GAUGE) WIRE - WITHIN CONDUIT.
(FROM SMART HUBS ROUTE ALONG MAIN LINE TO ISOLATION
VALVES OR REMOTE CONTROL VALVES)
WIRE COLOR SHALL BE RED.
INF34-336-6-7 TORO ROTARY POP-UP SPRINKLER-VALVE-IN-HEAD (FULL CIRCLE) WITH LYNX
SMART MODULE
INF35-316-6-7
INF35-346-6-7
INF35-316-6-7
TORO POP-UP GEAR DRIVEN ROTOR (TURF)T5-P-CK-E/3.0LA
PAIGE ELECTRICAL P7072D (14 GAUGE) WIRE - DIRECT BURY WITH PIPE - FEED
WIRE DOWN WIRE CHUTE OF PLOW WITH HDPE LATERAL LINE (ISOLATION
VALVES TO SPRINKLERS AND VALVES). COLOR ORANGE OR YELLOW.
1. IRRIGATION CONTROL WIRES: SOLID COPPER WITH U.L. APPROVAL FOR DIRECT BURIAL IN GROUND. SIZE #12AWG OR
#14AWG WIRE WITH A JACKETED 2-CONDUCTOR. PREFERRED WIRE MAKE AND MODEL IS PAIGE ELECTRIC MODEL NO.
P-7072D OR APPROVED EQUAL. USE AWG-#12 WITHIHN 1.5" CONDUIT TO ALL REMOTE CONTOL VALVES, ALONG THE
MAIN LINE TO ISOLATION VLAVE. USE #14 FROM ISOLATION VALVE TO SPRINKLERS OR APPROVED EQUAL. ROUTE ALONG
MAIN LINE AND LATERALS AS MUCH AS POSSIBLE.
2. GROUNDING SHALL BE PROVIDED EVERY EVERY 1000 FEET ALONG THE MAIN LINE , GROUND WITH A 5/8" X 8' COPPER
CLAD GROUNDING ROD AND GROUND PLATE. #6 COPPER WIRE TO SURGE DEVICE/DECODER. INCLUDE A SURGE ARRESTOR (TORO DEC-SG-LINE) AT EACH GROUNDING LOCATION. A CAD WELD CONNECTION TO BE USED TO CONNECT
THE SURGE DEVICE TO THE GROUND WIRE WITH A DBR/Y-6 OR WATERPROOF CONNECTOR. LOCATE THE GROUND ROD
IN THE ISOLATION VALVE BOX AND THE GROUND PLATE
3. AT LOCATIONS WHERE SURGE ARRESTORS ARE INSTALLED USE A 14"x19" PLASTIC VALVE BOXES.
4. SPLICING OF COMMUNICATION WIRE WILL NOT BE PERMITTED EXCEPT AT SPRINKLERS AND AT ISOLATION VALVES. LEAVE A 24" COIL OF EXCESS WIRE AT EACH SPLICE. WHERE SPLICING IS REQUIRED, BESIDES AT THE ISOLATION VALVES, LOCATE
IN A 10" DIAMETER ELECTRICAL BOX.
5. SMART HUB LOCATIONS ARE DIAGRAMMATIC. THE EXACT LOCATION WILL BE DETERMINED ON SITE PRIOR TO
INSTALLATION.
6. GROUNDING OF COMPUTER & SMART HUB EQUIPMENT SHALL BE IN COMPLIANCE WITH THE MANUFACTURERS RECOMMENDATIONS. PROVIDE AND INSTALL AN APC SMART UPS 1500VA AND AN INTERMATIC AG2401 POWER SURGE
ARRESTOR ON THE INCOMING POWER SUPPLY FROM THE EXISTING CONTROLLER.
11. INSTALL 3" DETECTABLE TAPE ABOVE ALL 4" AND 6" PRESSURIZED MAIN LINES AS DETAILED.
12. THE LOCATIONS OF THE AIR VENT/VACUUM RELIEF VALVES ARE APPROXIMATE, PRECISE LOCATIONS SHALL BE DETERMINED
ON SITE DURING IRRIGATION STAKING.
13. FIELD STAKING OF THE SPRINKLERS WILL BE COMPLETED IN THE FIELD BY THE IRRIGATION CONSULTANT. THE CONTRACTOR SHALL NOTIFY THE CONSULTANT A MINIMUM OF 3 DAYS PRIOR TO PROVIDING STAKING VISITS.
14. IRRIGATION PLANS ARE DIAGRAMMATIC. NO TRENCHING OR PLOWING OF WIRE OR PIPE WILL BE PERMITTED IN GREENS, TEES AND SAND TRAPS
15. ALL SPRINKLER HEADS SHALL BE SET PERPENDICULAR TO FINISH GRADE OF THE AREAS TO BE IRRIGATED
16. PRESSURE SETTINGS AT EACH VALVE IN HEAD SPRINKLER SHALL BE FACTORY SET AT 65 PSI.
17. CONTRACTOR SHALL REMOVE ALL EXISTING SPRINKLERS, QCV'S AND CONTROLLERS. DO NOT DAMAGE EQUIPMENT
DURING REMOVAL.
18. ISOLATION VALVES SHALL BE LOCATED NO CLOSER THAN FOUR FEET ON CENTER ALONG THE MAIN LINE AND A MINIMUM
OF FOUR FEET FROM THE PIPE ENDS.
19. INSTALL GREEN BOXES FOR ALL ISOLATION VALVES, BLACK BOXES FOR GATE VALVES AND GRAY BOXES FOR ELECTRICAL.
INSTALL RECYCLED WATER DECALS AND ID TAGS AS DETAILED.
20. WHERE IT IS NECESSARY TO EXCAVATE ADJACENT TO EXISTING TREES, USE CAUTION TO AVOID INJURY TO TREES AND TREE ROOTS. EXCAVATE BY HAND IN AREAS WHERE TWO (2) SPRINKLERS INCH AND LARGER ROOTS OCCUR. PAINT ROOTS ONE
(1) INCH AND LARGER IN DIAMETER WITH TWO COATS OF TREE SEAL, OR EQUAL. DO NOT TRENCH ACROSS ROOTS.
APPROACH THE TREE WITH A SINGLE LINE IN A RADIAL DIRECTION. ROUTE MAIN LINE AROUND TREES AS REQUIRED. OBTAIN
OWNERS APPROVAL OF MAIN LINE TRENCH ROUTE PRIOR TO TRENCHING.
IRRIGATION NOTES
P220GS-27-9-6 TORO 1.5" REMOTE CONTROL VALVE WITH PRESSURE REDUCING VALVE. SET TO
60 PSI.
TORO ROTARY POP-UP SPRINKLER-VALVE-IN-HEAD (FULL CIRCLE-SMALL RADIUS)
WITH LYNX SMART MODULE
TORO ROTARY POP-UP SPRINKLER-VALVE-IN-HEAD (PART CIRCLE) WITH LYNX
SMART MODULE
TORO ROTARY POP-UP SPRINKLER-VALVE-IN-HEAD (PART CIRCLE-SMALL RADIUS)
WITH LYNX SMART MODULE
LA DEC-SG-LINE
DEC-RSP-1000-DR TORO SMART HUB PEDESTAL MOUNTED AND
RADIO COMMUNICATION TO CENTRAL (GREEN
ENCLOSURE)
TORO LIGHTNING ARRESTOR WITH 8' GROUND
ROD ( #182000) AND PAIGE GROUNDING PLATE
(#182199IC)
B
LSM-1 TORO SMART MODULE. INSTALL WITHIN VALVE BOX AND WIRE TO
EXISTING VALVE. USE 3M-DBR6 WATERPROOF SPLICE KITS FOR ALL
SPLICES.
2760 Camino Diablo Walnut Creek, CA 94597 t
Russell D. Mitchell Associates, Inc.
Irrigation Consultant:
IRRIGATION DETAILS
I-5
NONE
SCALE: NONE
8 SMART HUB IN ENCLOSURE
1.5"
24" MIN.
12"
IRRIGATION SMART HUB-SET LEVEL 2-1.25" SCH 40 PVC CONDUITS 240
VOLT A.C. ELECTRICAL SERVICE FROM
SOURCE TO CONTROLLER AND
COMMUNICATION CABLE.
LOW VOLTAGE CONTROL WIRING.
CONCRETE PAD-6" THICK (MIN.) EXTEND
12" BEYOND EACH SIDE AND BACK, 24"
IN FRONT. PAD SHALL BE 1.5" ABOVE
FINISH GRADE.
FINISH GRADE.
4" SCH 40 GREY PVC ELECTRICAL
CONDUITS WITH SWEEP ELL FOR LOW
VOLTAGE WIRES. 18" BELOW GRADE.
1" PVC CONDUIT WITH SWEEP ELL FOR
GROUND WIRE.
24" MIN. AND OR 12" BEYOND
CONCRETE BASE.
6 6" ROUND BLACK PLASTIC BOX WITH
T-LID FOR GROUND ROD.
CADWELD CONNECTIONS7
CONTROLLER BOX MARKER DECAL
SHOWN AFFIXED TO BOX EXTERIOR
(PLACE TO INTERIOR OF BOX IF
POSSIBLE) T CHRISTY ENTERPRISES,
INC. MODEL 4100 OR EQUAL.
#6 AWG SOLID BARE COPPER WIRE -
INSTALL WITHOUT SHARP BENDS.
PROVIDE 12" COVER OVER WIRE.
8' LONG COPPER GROUND RODS
(PLACE 3 RODS IN A 16 FOOT
TRIANGULAR PATTERN) SEE
GROUNDING DETAIL
18" MIN.
SCALE: NONE
5 WEATHERPROOF WIRE SPLICE ASSEMBLY
INSTRUCTIONS:
1. STRIP WIRES APPROXIMATELY 1/2" FROM ENDS TO EXPOSE WIRE.
2. TWIST CONNECTOR AROUND WIRES CLOCKWISE UNTIL HAND TIGHT, DO NOT
OVERTIGHTEN.
3. INSERT WIRE ASSEMBLY TO BOTTOM OF GEL-FILLED TUBE. CHECK TO MAKE SURE
CONNECTOR HAS BEEN PUSHED PAST LOCKING FINGERS AND IS SEATED AT THE
BOTTOM OF THE TUBE.
4. PLACE WIRES WHICH EXIT TUBE IN WIRE EXIT HOLES AND CLOSE CAP UNTIL IT SNAPS.
5. INSPECT FINAL SPLICE ASSEMBLY THAT IT IS SECURED.
NOTE:
MAXIMUM # OF WIRES PER CONNECTOR:
· 3-#14 GAUGE
· 2-#12 GAUGE
STEP 5STEP 4
STEP 1
STEP 2
STEP 3
SCALE: NONE
4 TRENCHING
CLEAN BACKFILL MATERIAL.
FINISH GRADE.
LATERAL LINE (SUB-MAIN)
MAIN LINE.
COMMUNICATION CABLE FROM SMART HUB TO ISOLATION VALVES. INSTALL IN
1.25" CONDUIT BELOW SHOULDER OF PIPE.
NOTES:
1. REUSE SALVAGED EXCAVATED FILL AND COMPACT TO ORIGINAL DENSITY IN
LANDSCAPE AREAS. BACKFILL MATERIAL SHALL BE THE EARTH EXCAVATED
FROM THE TRENCHES, FREE FROM ROCKS (ANYTHING LARGER THAN 2"),
CONCRETE CHUNKS, AND OTHER FOREIGN OR COARSE MATERIALS.
4"
REFER TO
LEGEND
18"
SPLIT BOLT CONNECTORS. WRAP
WITH 6 THICKNESSES OF
ELECTRICAL TAPE AND PLACE
INTO SCOTCHCAST #4 SEAL
PACK. SIZE AS REQUIRED.
BRICK-ONE PER CORNER
SCHEDULE 40 U.L. LISTED PVC
CONDUIT
3/4" DRAIN ROCK-6" DEEP.
EXTEND 3" MIN BEYOND BRICKS
SCALE: NONE
TWO WIRE PULL BOX
FINISH GRADE1
1 9
SCHEDULE 40 PVC SWEEP ELLS6
7 SEAL CONDUIT OPENINGS WITH
WATERPROOF FOAM.
19 GAUGE S.S 1/2" SQUARE
WIRE MESH. WRAP UP SIDES OF
BOX.
GREY RECTANGULAR PLASTIC
BOX WITH T-LID. (BOLT DOWN)
14" x 19" x 12" DEEP. MARK
COVER: "ELECTRICAL".
Controller Unit for Recycled Water
Unidad Controladora del Agua Recuperada
CONTROLLER BOX MARKER DECAL SHOWN AFFIXED
TO BOX EXTERIOR (PLACE TO INTERIOR OF BOX IF
POSSIBLE) T CHRISTY ENTERPRISES, INC. MODEL 4100
OR EQUAL.
ATTENTION
ATENCION
TWO WIRE CABLE (DIRECT BURY)4
3" DETECTABLE WARNING TAPE OVER MAIN LINE. INSTALL 3" ABOVE MAIN LINE.
USE CHRISTY MODEL #TA-DT-3-PRW FOR RECYCLED IRRIGATION WATER SYSTEMS
PURPLE ID DECAL DRILLED INTO
THE LID
SCALE: NONE
3" MIN.
3" MIN.
PEA GRAVEL OR 3/4" DRAIN ROCK
FINISH GRADE
BRICK-2 TOTAL
1 6
LEEMCO LMJD-SERIES (PIPE TO
VALVE) RESTRAINT OR EQUAL.
ONE EACH SIDE OF VALVE
8" C900 OR SCHEDULE 40 PVC PIPE (NOTCH
TO FIT OVER MAIN LINE PIPE)
FLANGED END GATE VALVE W/ 2" SQUARE
AWWA OPERATING NUT SEE LEGEND FOR
SPECS.
C900 PVC MAIN LINE8
FLANGE GATE VALVE - 4" AND LARGER (C900)
NOTE:
SUPPORT VALVE WITH
2" x 4" REDWOOD
STAKES AS REQUIRED
FINISH GRADE
SCALE: NONE
AIR RELIEF VALVE3
1" BRASS BALL VALVE5
12" CONCRETE PAVER SUPPORT BLOCK
10 PEA GRAVEL OR 3/4" DRAIN ROCK- 4" DEEP
BELOW VALVE (NO SOIL IN VALVE BOX).
MAIN LINE AIR RELIEF VALVE
1 2
14 16
1" BRASS NIPPLE (3" IN LENGTH) 2
TOTAL.
1" BRASS NIPPLE (4" IN LENGTH)6
1" THREADED 90°7
9 BRICK SUPPORT. (4 TOTAL/ 1 @ EA
CORNER).
11 C900 GASKETED PVC MAIN LINE
12 1" BRASS NIPPLE (LENGTH AS REQUIRED
DEPENDING ON MAIN LINE DEPTH). USE BRASS
REDUCER BUSING AT TAPPED TEE.
13 C900 DUCTILE IRON DOUBLE STRAPPED SADDLE
WITH 2" THREADED OUTLET. HARCO MODEL
80490H4 (4"), 80690H4 (6"), 80890H4 (8").
1" BRASS CAP15
16 1" BRASS NIPPLE (LENGTH AS REQUIRED
DEPENDING ON MAIN LINE DEPTH)
INSTALLATION INSTRUCTIONS:
1. LUBRICATE THE GASKET IN THE MATING FEMALE SWIVEL JOINT AND THE INLET SPIGOT OF
THE VALVE WITH PVC PIPE LUBRICANT.
2. ROTATE MALE THREAD "IN" UNTIL JOINT BOTTOMS OUT."
3. ROTATE MALE THREAD "OUT" TO PROPER HORIZONTAL ORIENTATION FOR VALVE UP TO
AND NO MORE THAN 360°.
4. INSTALL BEVEL PIPE IN OUTLET BELL AFTER LUBRICATING OUTLET GASKET AND PIPE END.
REMOVE WOOD WEDGE AND TIGHTEN RESTRAINT BOLT TO 35 FT-LBS.
+-18"
14"
4 9
SCALE: NONE
ANGLE ISOLATION VALVE3
3/4" DRAIN ROCK 6" DEEP
FINISH GRADE
2" SCH 40 PVC PUPLE PIPE TO SPRINKLERS.
USE 2" x 3" SCH 80 REDUCER TO INCREASE
TO 3" FOR GREENS LOOP.
BRICK - 2 TOTAL
FEMALE SWIVEL SADDLE FOR DIPS, HARCO
MODEL 80491H (4"), 80691H (6")
PURPLE C900 PVC MAIN LINE
1 2"x6" GASKET BY MALE SWIVEL S.S.
LATERAL ISOLATION VALVE. HARCO
MODEL 8411062PQ.
PURPLE RECYCLED WATER WARNING TAG10
CARSON 1730 -15" DEPTH BOX.
PURPLE RECYCLED WATER WARNING TAG.
REFER TO
IRRIGATION
LEGEND
1" BRASS THREADED TEE17
18 GAUGE 1/2" SQUARE STAINLESS
STEEL WIRE MESH. WRAP UP SIDES
OF THE BOX. ANCHOR TO BOX
WITH S.S. SCREWS AND WASHER
AS REQUIRED.
3"
LOCATE COMMON GROUND WIRE
SPLICES BETWEEN VALVE BOX AND SLEEVE
10" ROUND GREEN LID AND VALVE BOX
WITH RECYCLED WATER DECAL INSTALLED
ON LID
6" FLEXIBLE DRAIN PIPE - EXTEND BELOW
BOTTOM OF VALVE
PURPLE RECYCLED WATER WARNING
TAG. DRILL A HOLE INTO SLEEVE.
ATTACHED WITH S.S. ZIP TIE.
10" ROUND GREEN LID AND VALVE BOX WITH
RECYCLED WATER DECAL INSTALLED ON LID
PURPLE ID DECAL DRILLED INTO
THE LID
PURPLE ID DECAL DRILLED INTO THE LID19
SCALE: NONE
6 THRUST BLOCK
1 1/4° BEND REDUCER END CAP
22 1/2°
OR 45° BENDWYETEE
TEE W/ STUB 90° BENDCROSS
CONCRETE THRUST BLOCK SHALL HAVE CONTACT WITH FITTING ONLY AND REMAIN CLEAR
OF PIPE AND JOINTS.
THRUST BLOCK TO BE CONSTRUCTED OF 3000 PSI CONCRETE.
BLOCK TO BE POURED AGAINST UNDISTURBED SOIL.
1.
2.
3.
SCALE: NONE
THRUST BLOCK INSTALLATION7
14"x14"
L
A
1.2.93
45° BEND
12"x12"16"x16"
90° BEND
1.7
NOTES:
DISTANCE "A" TO BE 18" MINIMUM FROM FITTING TO UNDISTURBED SOIL. THRUST BLOCKS
SHALL BE POURED ONLY AGAINST UNDISTURBED EARTH.
REFER TO THRUST BLOCK CHART FOR DISTANCE "L" AND "H".
CONCRETE TO BE SHAPED INTO A WEDGE WITH THE WIDE END AGAINST THE SOLID WALL
OF THE TRENCH.
CONCRETE SHALL BE KEPT BEHIND THE BELL OF THE FITTING WITH THE CONCRETE NOT
PERMITTED TO RUN OVER AGAINST THE PIPE OR ONTO THE JOINT.
THE FIGURES IN THIS CHART ARE BASED ON A WORKING PRESSURE OF 150 PSI.
1.
2.
3.
THRUST BLOCKING APPLIES TO 4" AND LARGER PIPE ONLY.4.
5.
L x H L x H L x H
BEARING
AREA
(SQUARE FT.)
4"
TEES,DEADENDS &VALVES
H (MAX. 3' [1m])
PIPE SIZE
BEARING
AREA
(SQUARE FT.)
BEARING
AREA
(SQUARE FT.)
SCALE: NONE
SMART HUB GROUNDING DETAIL9
2760 Camino Diablo Walnut Creek, CA 94597 t
Russell D. Mitchell Associates, Inc.
Irrigation Consultant:
IRRIGATION DETAILS
I-6
NONE
FINISH GRADE1
SCH 40 PVC LATERAL LINE
NOTE:
INSTALL UNI-BODY
NIPPLE ON RISER
ASSEMBLY 30° UP
FROM HORIZONTAL.
VALVE-IN-HEAD SPRINKLER (PURPLE
MARKING) SET FLUSH WITH FINISH
GRADE AT THE TIME OF INSTALLATION.
LOCATE ALL SPLICES WITHIN INFINITY
SPRINKLER COMPARTMENT. USE
3M-DBR6 WATERPROOF SPLICE KITS
FOR ALL SPLICES.
SCALE: NONE
1 TORO INFINITY SPRINKLER RISER
18"
REMOTE CONTROL VALVE
SCALE: NONE
3" MIN 6" MAX
REMOTE CONTROL VALVE WITH FLOW
CONTROL AND MANUAL BLEED AND
PRESSURE REGULATOR
SCH 40 PVC SUB MAIN LINE
PEA GRAVEL- 4" DEEP BELOW VALVE
(NO SOIL IN VALVE BOX)
PROVIDE 3M-DBY SEAL PACKS AT
ALL SPLICES AND 36" OF EXCESS
WIRE IN VALVE BOX.
REFER TO IRRIGATION LEGEND
BRICK-1 EACH CORNER
19 GAUGE 1/2" SQUARE WIRE
MESH. WRAP UP SIDES OF BOX.
FINISH GRADE
7 8
RECTANGULAR PLASTIC VALVE BOX
WITH BOLT DOWN LID. INSTALL BOX
AS SHOWN IN BOX INSTALLATION
DETAIL. TOP DIMENSION: 11 3/4" X
17" (12" DEEP)
LATERAL LINE TO SPRINKLERS
FRONT
WARNING
NO TOMAR
AGUA IMPURA
AVISO
SCALE: NONE
IDENTIFICATION OF RECYCLED WATER
WARNING TAG
BACK
SAMPLE WARNING TAG. BACKGROUND PURPLE
(PANTONE 512) WITH BLACK LETTERING.
RECYCLED WATER
DO NOT DRINK
SCALE: NONE
IRRIGATION BOX COVER/LIDS WITH WARNING
SIGN
REFERENCE: T. CHRISTY ENTERPRISES, INC.
CATALOG PART NO. 3800 OR EQUAL
PURPLE ID DECAL DRILLED INTO THE
LID FOR RECYCLED SYSTEMS.
PURPLE ID DECAL DRILLED INTO
THE LID FOR RECYCLED
SYSTEMS.
PURPLE ID DECAL DRILLED INTO
THE LID
PURPLE RECYCLED WATER WARNING
TAG. ATTACHED WITH S.S. ZIP TIE.
RECYCLED WATER
DO NOT DRINK-NO TOMAR
RECYCLED WATER
INSTALLATION NOTES:
1. ACME O-RING SEALED THREADS ARE TO BE FINGER TIGHTENED AND "BACKED OFF"
ONE FULL ROTATION BEFORE INSTALLATION.
2. THE SWING JOINT LAY ARM IS TO BE INSTALLED AT AN ANGLE BETWEEN 30° AND
45°.
SCALE: NONE
3 QUICK COUPLING VALVE
SIDE VIEW
7" ROUND PLASTIC VALVE BOX
WITH BOLT DOWN LID
QUICK COUPLING VALVE WITH PURPLE TOP.
FINISH GRADE
BRICK - 2 TOTAL.
PEA GRAVEL- 4" DEEP BELOW VALVE (NO
SOIL IN VALVE BOX).
FOR 1" Q.C.V. USE LASCO 1" SWING
JOINT, 1
2" ACME INLET X 1" SNAP-LOC
BRASS MIPT OUTLET, MODEL
#G1MS-218. FOR 11
2" Q.C.V., USE LASCO
2" SWING JOINT, 11
2" ACME INLET X
2" SNAP-LOC BRASS MIPT OUTLET,
MODEL #G3MS-218.
2"
1 2
1" SCH 40 PVC PIPE STABLIZER. 12" LENGTH4
2-#4 REBAR. 24" IN LENGTH5
SUB MAIN LINE6
LASCO HEAVY TURF 2" SERVICE TEE
WITH A 1.5" ACME OUTLET
(SxSxACME) LASCO MODEL #302251
LASCO JOINT WITH MALE ACME THREADS.
315 PSI RATED MODEL #G1M0-212 (1.5"
ACME INLET TO 1" ACME OUTLET INTO
SPRINKLER). ADJUST ANGLE OF SWING
JOINT LAY ARM BETWEEN 30° TO 45° TO
ALLOW ADEQUATE IMPACT ABSORPTION.
DO NOT USE TEFLON TAPE OR PIPE DOPE
WITH ACME THREADS.
SCH 80 TOE NIPPLE
LASCO HEAVY TURF SURGE GUARD PVC
90° ELBOW
(SXS)
SCHEDULE 40 PVC PIPE
LASCO HEAVY TURF SURGE GUARD
PVC TEE
LASCO HEAVY TURF 2" SERVICE TEE WITH
A 1.5" ACME OUTLET (SxSxACME) LASCO
MODEL #302251
SCALE: NONE
4 POP-UP ROTARY SPRINKLER - NON-VIH
TOP VIEW
SIDE VIEW
PVC LATERAL LINE.
POP-UP ROTARY SPRINKLER.
FINISH GRADE.
REFER TO
IRRIGATION
LEGEND
LASCO HEAVY TURF SURGE GUARD
PVC TEE OR ELBOW WITH THREADED
OUTLET.
UNITIZED SWING JOINT: 3/4"-LASCO
MODEL T732-212
1"-LASCO MODEL T932-212.
SCALE: NONE
GROUNDING OF COMMUNICATION CABLE5
TWO WIRE
CABLE FROM
SPLICE IN
ISOLATION
VALVE BOX
TWO WIRE
CABLE TO
NEXT
SPRINKLER
OR VALVE
2760 Camino Diablo Walnut Creek, CA 94597 t
Russell D. Mitchell Associates, Inc.
Irrigation Consultant:
IRRIGATION DETAILS
I-7
NONE
3. MAIN /LATERAL SEPARATION STANDARDS
SCALE: NONE
REQUIREMENTS FOR HORIZONTAL AND VERTICAL PIPELINE SEPARATION1
* 12" MIN VERTICAL SEPARATION REQUIREMENT
* CASING REQUIRED IF VERTICAL SEPARATION
REQUIREMENT NOT MET
* 48" MIN HORIZONTAL SEPARATION
REQUIREMENT
POTABLE WATER
SLEEVE**
POTABLE WATER
SLEEVE**
SANITARY SEWER
RECYCLED WATER
SLEEVE**
CROSSING #1
CROSSING #2
* 12" MIN VERTICAL SEPARATION
REQUIREMENT
* 12" MIN VERTICAL SEPARATION
REQUIREMENT
* SLEEVE RW PIPELINE 5 FEET FROM
CENTERLINE OF PW PIPELINE
* NO JOINTS FOR EIGHT FEET ON
EITHER SIDE OF POTABLE WATER
CROSSING
1. PARALLEL SEPARATION
STANDARDS
POTABLE WATER
STORM DRAINS OR
SANITARY SEWER
SLEEVE**
2. CROSSING SEPARATION STANDARDS
SITUATION CRITERIA
PARALLEL
RECYCLED WATER
RECYCLED WATER
CRITERIA
RECYCLED
WATER
SANITARY SEWER
BASIC SEPARATION STANDARDS:
1. POTABLE AND RECYCLED PIPELINES SHALL NOT TO BE INSTALLED IN THE SAME TRENCH.
RECYCLED PIPELINES SHALL BE DESIGNED TO BE INSTALLED BELOW THE POTABLE
PIPELINES WHERE THE TWO PIPELINES RUN PARALLEL TO EACH OTHER. WHERE THIS IS
NOT POSSIBLE, THE RECYCLED PIPELINE SHALL BE INSTALLED IN A CASING. DETAILS OF
THIS INSTALLATION SHALL BE CLEARLY SHOWN ON THE PLANS.
2. PARALLEL CONSTRUCTION
A. THE HORIZONTAL SEPARATION BETWEEN ONSITE RECYCLED AND POTABLE LINES
SHALL BE A MINIMUM OF FORTY-EIGHT (48) INCHES, MEASURED BETWEEN
OUTSIDE DIAMETERS. (SEE DETAIL 1)
3. CROSSING CONSTRUCTION
A. IN GENERAL, ONSITE RECYCLED WATER LINES SHALL BE INSTALLED BELOW
POTABLE WATER LINES, WITH A MINIMUM VERTICAL SEPARATION OF TWELVE
(12) INCHES, MEASURED BETWEEN OUTSIDE DIAMETERS. (SEE DETAIL 2
CROSSING #1) EXCEPTIONS TO THIS GENERAL REQUIREMENT ARE AS
FOLLOWS:
i. RECYCLED WATER LINES MAY BE INSTALLED ABOVE POTABLE WATER
LINES WHERE THE RECYCLED LINES (LATERALS) ARE INTERMITTENTLY
PRESSURIZED. NO SPECIAL CONSTRUCTION REQUIREMENTS ARE
NECESSARY, PROVIDED THE TWELVE (12) INCHES VERTICAL
SEPARATION IS MAINTAINED.
ii. CONSTANTLY PRESSURIZED RECYCLED WATER LINES MAY BE INSTALLED
ABOVE POTABLE WATER LINES PROVIDING THE RECYCLED PRESSURED
LINE HAS AN AUTOMATIC FLOW CONTROL/SHUT-OFF DEVICE
INSTALLED, OR THE RECYCLED LINE IS SLEEVED. AN AUTOMATIC FLOW
CONTROL/SHUT-OFF DEVICE SHALL TERMINATE ALL FLOW TO A
LATERAL AUTOMATICALLY SHOULD THE FLOW EXCEED A PRESET
MAXIMUM GPM. SLEEVING SHALL EXTEND FIVE (5) FEET EACH SIDE
FROM THE CENTER-LINE OF THE POTABLE LINE, FOR A TOTAL LENGTH
OF TEN (10) FEET . THE SLEEVE SHALL BE PURPLE PVC. IN ALL CASES,
THE TWELVE (12) INCHES VERTICAL SEPARATION SHALL BE
MAINTAINED. (SEE DETAIL 2 CROSSING #2)
B. WHEN CROSSING A POTABLE WATER MAIN THE CROSSING SHOULD BE AS
CLOSE AS PRACTICAL TO THE PERPENDICULAR AND NO LESS THAN 45 DEGREES.
4. RECYCLED WATER FACILITIES (ONSITE) SHALL BE DESIGNED/INSTALLED TO THE
FOLLOWING MINIMUM TOP OF PIPE DEPTH REQUIREMENTS:
A. INTERMITTENT PRESSURE LINES TWO (2) INCHES AND SMALLER: TWELVE (12)
INCHES.
B. CONSTANT PRESSURE LINES SMALLER THAN SIX (6) INCHES: EIGHTEEN (18)
INCHES.
C. CONSTANT PRESSURE LINES SIX (6) INCHES AND LARGER: THIRTY (30) INCHES.
GENERAL NOTES
1. PROPER CORROSION PROTECTION TO PIPELINES IS REQUIRED
WHICH INCLUDES BUT IS NOT LIMITED TO OUTSIDE COATING, INSIDE
LINING, DIELECTRIC TREATMENT, AND OTHER CATHODIC PROTECTION.
2. STANDARD SPECIFICATION ARE DETAILED IN THE NMWD STANDARD
SPECIFICATION SECTION 15152 - RECYCLED WATER FACILITIES
(ONSITE), ANY EXCEPTIONS TO THESE REQUIREMENTS REQUIRE A
SPECIAL REVIEW BY NMWD AND APPROVAL SHALL BE GRANTED BY
THE CALIFORNIA DEPARTMENT OF PUBLIC HEALTH.
SCALE: NONE
BASIC SEPARATION STANDARD NOTES
SCALE: NONE
BASIC SEPARATION STANDARD NOTES
CONTINUE
#14AWG TWO WIRE CABLE FROM SMART
HUB.
LYNX SMART MODULE
TWO WIRE CABLE TO NEXT DECODER
ALL DECODERS SHALL BE ADDRESSED AND INPUTTED INTO CENTRAL
COMPUTER.
NOTE:
1.
8 EXISTING VALVE BOX.
9 EXISTING REMOTE CONTROL VALVE.
3M DBR/Y-6 OR APPROVED EQUAL
WATERPROOF SPLICE KIT (4 TOTAL)
LYNX SMART MODULE WIRING
SCALE: NONE
DECODER
USE U.F. SAFETY CABLE STRIPPER BY KING INNOVATION (MODEL
NUMBER 46200) FOR ALL TWO-WIRE SPLICE CONNECTIONS.
2.
A MAXIMUM OF 4" OF WIRE SHALL BE
STRIPPED FROM TWO WIRE CABLE WHEN
SPLICING AT DECODERS.
CONNECT CORRECT DECODER WIRES
TO VALVE SOLENOID WIRES
5 CONNECT CORRECT DECODER WIRES TO
TWO WIRE CABLES.
| Sheets and Views |
| Lincoln_Park_GC_Irrigation_Design-I-1 |
| Lincoln_Park_GC_Irrigation_Design-I-2 |
| Lincoln_Park_GC_Irrigation_Design-I-3 |
| Lincoln_Park_GC_Irrigation_LND-I-4 |
| Lincoln_Park_GC_Irrigation_LND-I-5 |
| Lincoln_Park_GC_Irrigation_LND-I-6 |
| Lincoln_Park_GC_Irrigation_LND-I-7 |
File details come from the government source that posted it. Updated .