Text version

P.O. Box 13216 Lansing, MI 48901 Phone: 888.449.4566 Fax: 888.448.8739 www.redcedarconsulting.net

August 25, 2022

Julie Weist US FWS Pendills Creek NFH 21990 W Trout Lane Brimley, MI 49715

RE: Asbestos Containing Material Inspection 13415 S Asher Row Brimley, MI 49715 Parcel ID: Residential Building

Dear Ms. Weist:

Red Cedar Consulting has completed an asbestos-containing material (ACM) inspection at 13415 S Asher Row, Brimley, Michigan (Subject Property). This inspection was completed at the request of the US FWS to comply with the United States Environmental Protection Agency (USEPA) requirements for demolition and renovation set forth under the National Emissions Standards for Hazardous Air Pollutants (NESHAP, 40 CFR Part 61). This inspection was also completed to comply with the Occupational Safety and Health Administration (OSHA) Asbestos Standards for Construction (29 CFR 1926.1101) which limits employee exposure to asbestos.

SUBJECT PROPERTY

The Subject Property is comprised of a residential parcel which contains an approximate 1,200 square foot residential building with attached garage (the Building) with an unknown construction date. The Building was constructed on a concrete basement with one aboveground floor. The exterior walls of the Building were finished with clapboard siding while the roof was sealed with metal roofing. The Building can be further divided into a kitchen/dining room, living room, bathroom and three bedrooms.

VISUAL INSPECTION AND SAMPLING

Asbestos Containing Materials Inspection

Mr. Aaron Paquet of Red Cedar Consulting (Red Cedar), an accredited State Of Michigan/EPA Asbestos Building Inspector (Accreditation Number A30955) whom completed training per the Michigan Asbestos Workers Accreditation Act 440 completed an inspection of the Subject Property on July 19, 2022 for suspected asbestos containing building materials.

This inspection, and subsequent sample collection was completed in accordance with the USEPA Asbestos Hazard Emergency Response Act (AHERA) (40 CFR Part 763) assessment and sampling protocol.

Project No.: 22-1288

US FWS

Parcel ID: 13415 S Asher Row

During the completion of the inspection, each area of the Subject Property was visually inspected for asbestos containing building materials (ACBM). Following the completion of the visual inspection, Red Cedar staff identified each suspect area of friable and non-friable ACBM and sorted them into one of three homogenous categories for sampling purposes. AHERA defines friable as a material that when dry, may be crumbled, pulverized, or reduced to powder by hand pressure. A homogenous area is defined by OSHA as an area of surfacing, thermal system insulation (TSI) or miscellaneous material that is uniform in color and texture. Surfacing materials are most commonly found in sprayed-on, troweled-on or otherwise applied to surfaces, such as acoustical plaster on ceilings and fireproofing materials on structural members. TSI refers to materials applied to pipes, fittings, boilers, ductwork, or other components to prevent heat loss or gain, or condensation. Any material that does not fall under the surfacing or TSI category, such as floor tile, drywall, and acoustical ceiling tile are placed into the miscellaneous materials category.

Following the completion of the visual inspection, Red Cedar staff identified the following materials as suspect ACBM:

· Trim Caulk

· House Concrete

· Exterior Concrete

· 12x12 Vinyl Floor Tile

· Linoleum

· 1x1 Ceiling Tile/Glue Pods

· Drywall & Compound

· Window Glazing

· Stair Tread

· Window Caulk

· Fiberboard

· Light Paper

· Black Line Insulation

Red Cedar staff collected forty-five samples of suspect ACBM separated into fifteen distinct homogenous groups for laboratory analysis. Samples were collected and submitted to APEX Research Inc.

Laboratories (APEX) (Accreditation Number 102118-0) for laboratory analysis. Analysis was completed utilizing polarized light microscopy (PLM) which is the Environmental Protection Agency (EPA) approved method for analysis of bulk materials for asbestos. PLM analysis completed pursuant to method (EPA 600/M4-82-020) identifies asbestos fiber bundles by the visual properties displayed when the sample is treated with various dispersion staining liquids. The laboratory report completed following the sample analysis indicates if asbestos is present, and at what percentage along with a description and percentage of other fibrous and non-fibrous materials and sample color. Chain-of-custody documentation was followed from sample collection through shipping and receiving of the samples at the designated laboratory. The documentation assures that samples will meet the quality assurance/quality control measures defined by AHERA. The laboratory analytical report prepared by APEX for the forty-five samples is included as Attachment A.

INSPECTION RESULTS AND RECOMMENDATIONS

During the completion of the asbestos inspection, forty-five samples of suspect ACM were collected and are documented in Table 1 along with the Red Cedar sample number, description, friability, material type, ACM classification, sample location, material quantity and laboratory analytical results. A Site Diagram was prepared which provides the general building layout and sample locations and is included as Attachment B.

ACM, as defined by the USEPA NESHAP is “any material containing more than 1 percent asbestos as determined using the method specified in appendix E, subpart E, 40 CFR part 763 Section 1, Polarized Light Microscopy”.

Friable ACM is defined by NESHAP as any material containing more than 1 percent asbestos that, when dry, can be crumbled, pulverized, or reduced to powder by hand pressure. Friable ACM is a concern due the ease of unintentionally disturbing the ACM which may result in “visible emissions” which is known as a Fiber Release Episode.

Non-friable asbestos-containing material is defined as “material containing more than 1 percent asbestos that, when dry, cannot be crumbled, pulverized, or reduced to powder by hand pressure. Non-friable ACM’s are separated into Category I and Category II ACM. Category I ACM is any asbestos containing packing’s, gaskets, resilient floor coverings (vinyl floor tile and linoleum are examples of these) and asphalt roofing products. Category II ACM is stated by NESHAP as any material excluding Category I non-friable ACM such as drywall, plaster or fiberboard insulation.

Presumed Asbestos Containing Material

Presumed Asbestos Containing Materials (PACM) are suspect surfacing, TSI and miscellaneous materials found in buildings constructed prior to 1980 which are classified as and due to the age of the structure, are assumed to be ACM and do not require sample collection and analysis. OSHA dictates that PACM may be “rebutted” following a complete inspection pursuant to AHERA protocol.

No PACM was identified during the completion of this inspection. All suspect materials identified were sampled and analyzed for ACM.

Table 2 lists the location, material description, friability, condition, material type (surfacing, thermal or miscellaneous) and approximate quantity of all PACM documented at the Subject Property.

Table 3 provides a summary all ACM documented at the Subject Property which includes the material location, description, and approximate quantity.

Friable ACM’s

A window glazing sample collected from a window in the garage was found to contain up to 1.25% asbestos following analysis. The assessment to quantify the extent of this material identified two windows within the Building that would fall into the same homogenous group. The locations of the windows are listed below:

· Garage (2 window)

Parcel ID: 13415 S Asher Row

Light Backer Paper identified in the Kitchen in conjunction with the lighting system was sampled and found to contain up to 40% asbestos following analysis. The visual assessment to quantify the extent of this material identified this material at the following locations.

· Kitchen (1 Light)

Category I ACM

Two types of resilient floor covering (Tan 12x12 VFT ML and White Mottled Lin. ML) located within the kitchen and bathroom, respectively, were found to contain up to 1.75% Chrysotile asbestos. The assessment to quantify the extent of this material identified approximately 250 sq. ft. of this material within the Building.

Category II ACM

Trim Caulk samples, collected from the Building were found to contain up to 1.5% asbestos following analysis. The assessment to quantify the extent of this material identified approximately 250 lin. ft. of Trim Caulk compound on the Building.

Drywall Compound samples collected from the Building were found to contain up to 1.25% asbestos following analysis. The assessment to quantify the extent of this material identified approximately 3,800

sq. ft. of drywall compound within the Building.

Glue Glue Pod samples collected from the Building were found to contain up to 1.75% asbestos following analysis. The assessment to quantify the extent of this material identified approximately 450

sq. ft. of glue pods within the Building.

Black Line Insulation Wrap samples collected from the Building were found to contain up to 25% asbestos following analysis. The assessment to quantify the extent of this material identified approximately 30 lin. ft. of Line Wrap within the Building.

RECOMMENDATIONS

Asbestos Containing Materials

The materials listed above and identified as ACM should be abated to mitigate any future exposure.

Please note: The location of samples obtained during this inspection were in a random fashion and areas that were not identified during this inspection may be damaged or have become damaged since the inspection was completed. If Category I or Category II friable materials are discovered prior to or during the demolition/renovation process, these materials must be abated prior to commencement of any demolition/renovation activities at the Subject Property.

REGULATORY REQUIREMENTS

A Notification of intent to Renovate/Demolish form must be filed with the Michigan Department of Environmental Quality- Air Quality Division at least 10 working days prior to any renovation or demolition activities at a site.

The Notification of Intent to Renovate/Demolish form must also be completed and submitted to the MIOSHA-Asbestos Program whenever demolition, encapsulation and/or renovation activities at a site involving greater than ten lineal feet and/or fifteen square feet of ACM will be completed.

Regulated asbestos containing materials per NESHAP (40 CFR Part 61) which falls into any of the following categories are ACM’s that must be removed prior to any renovation/demolition activities at the Subject Property.

· Friable asbestos material.

· Category I non-friable ACM that has become friable.

· Category I non-friable ACM that will be or has been subjected to sanding, grinding, cutting, or abrading.

· Category II non-friable ACM that has a high probability of becoming or has become crumbled, pulverized, or reduced to powder by the forces expected to act on the material in the course of renovation or demolition operations.

Asbestos abatement should only be performed by a certified asbestos abatement contractor licensed to complete abatement work. The contractor must also follow the standards and requirements set forth per the OSHA Asbestos Standards for Construction (29 CFR 1926.1101) and the USEPA NESHAP (40 CFR Part 61).

Additional information regarding the OSHA Asbestos Standards for Construction (29 CFR 1926.1101) and the USEPA NESHAP (40 CFR Part 61) can be obtained by contacting the associated agency below.

NESHAP Asbestos Program MIOSHA-CSHD-Asbestos Program Department of Environmental Quality State of Michigan Phone: 517-284-6777 Phone: 517-284-7680 Email: asbestos@michigan.gov

DISCLAIMER

Red Cedar Consulting performed destructive testing methods in an attempt to access and inspect all areas of the Building. Unfortunately, due to the age of construction along with multiple additions/renovations that may have been completed on the Building, additional inspections may be required if suspect ACM material not documented within this report is encountered during renovation/demolition activities.

This report was prepared at the request and for exclusive use by the US FWS and may not be reproduced or sold without written permission from Red Cedar Consulting.

We appreciate the opportunity to provide the requested services. Please contact us at (888) 449-4566 with any questions or concerns.

Sincerely, Red Cedar Consulting

Aaron Paquet

Michigan/EPA Certified Asbestos Building Inspector (A30955)

©2022 Red Cedar Consulting, LLC.

Attachment A

APEX Research Laboratory Analytical Results

Report To: ARI Report # 22-100644 Mr. Aaron Paquet Date Collected: 07/19/22 Red Cedar Consulting Date Received: 07/25/22 P.O. Box 13216 Date Analyzed: 07/28/22 Lansing, MI 48901 Date Reported: 07/29/22

Sample Information Asbestos Type/Percent Non-Asbestos Material

Lab ID #: 100644 - 01 Asbestos Present: YES Other - 98.50%

Cust. #: HU-HM-01A Chrysotile - 1.50% Material: Trim Caulk Location:

Appearance: beige,fibrous,homogenous POINT COUNT RESULT Layer: 1 of 1

Lab ID #: 100644 - 02 Asbestos Present:

Cust. #: HU-HM-01B Material: Trim Caulk Location: NOT ANALYZED Appearance:

Layer: of

Lab ID #: 100644 - 03 Asbestos Present:

Cust. #: HU-HM-01C Material: Trim Caulk Location: NOT ANALYZED Appearance:

Layer: of

For Layered Samples, each component will be analyzed and reported separately.

Robert T. Letarte Jr., Laboratory Director

Certificate of Laboratory Analysis Test Method, Polarized Light Microscopy (PLM)

Project : 13415 S. Asher Row.

Test Method EPA 40 CFR - Part 763 and/or EPA 600/R-93/116 was used to analyze the above samples. Matrix interference and/or resolution limits may yield false/negative results in certain circumstances. Suspect floor tiles containing <1% should be tested with SEM or TEM. This certificate of analysis relates only to the samples as submitted and to insure the integrity of the results, may only be reproduced in full. This certificate must not be used by the customer to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. APEX Research Inc. is not responsible for the accuracy of the results for layered samples or samples comprising multiple materials. Liability limited to cost of analysis.

NVLAP Lab Code 102118-0 APEX Research Inc., 11054 Hi Tech Drive, Whitmore Lake, MI 48189

(734) 449-9990, Fax (734) 449-9991 Page 1 of 23

Red Cedar Consulting Date Received: 07/25/22 P.O. Box 13216 Date Analyzed: 07/28/22 Lansing, MI 48901 Date Reported: 07/29/22

Certificate of Laboratory Analysis Test Method, Polarized Light Microscopy (PLM)

Project : 13415 S. Asher Row

Sample Information Asbestos Type/Percent Non-Asbestos Material

Lab ID #: 100644 - 04 Asbestos Present: NO Other - 100%

Cust. #: HU-HM-02A No Asbestos Observed Material: Basement/Garage Concrete Location:

Appearance: grey,nonfibrous,homogenous Layer: 1 of 1

Lab ID #: 100644 - 05 Asbestos Present: NO Other - 100% Cust. #: HU-HM-02B No Asbestos Observed Material: Basement/Garage Concrete Location:

Appearance: grey,nonfibrous,homogenous Layer: 1 of 1

Lab ID #: 100644 - 06 Asbestos Present: NO Other - 100% Cust. #: HU-HM-02C No Asbestos Observed Material: Basement/Garage Concrete Location:

Appearance: grey,nonfibrous,homogenous Layer: 1 of 1

For Layered Samples, each component will be analyzed and reported separately.

Robert T. Letarte Jr., Laboratory Director

Test Method EPA 40 CFR - Part 763 and/or EPA 600/R-93/116 was used to analyze the above samples. Matrix interference and/or resolution limits may yield false/negative results in certain circumstances. Suspect floor tiles containing <1% should be tested with SEM or TEM. This certificate of analysis relates only to the samples as submitted and to insure the integrity of the results, may only be reproduced in full. This certificate must not be used by the customer to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. APEX Research Inc. is not responsible for the accuracy of the results for layered samples or samples comprising multiple materials. Liability limited to cost of analysis.

NVLAP Lab Code 102118-0

(734) 449-9990, Fax (734) 449-9991 Page 2 of 23

Red Cedar Consulting Date Received: 07/25/22 P.O. Box 13216 Date Analyzed: 07/28/22 Lansing, MI 48901 Date Reported: 07/29/22

Certificate of Laboratory Analysis Test Method, Polarized Light Microscopy (PLM)

Project : 13415 S. Asher Row

Sample Information Asbestos Type/Percent Non-Asbestos Material

Lab ID #: 100644 - 07 Asbestos Present: NO Other - 100%

Cust. #: HU-HM-03A No Asbestos Observed Material: Approach/Sidewalk Concrete Location:

Appearance: grey,nonfibrous,homogenous Layer: 1 of 1

Lab ID #: 100644 - 08 Asbestos Present: NO Other - 100% Cust. #: HU-HM-03B No Asbestos Observed Material: Approach/Sidewalk Concrete Location:

Appearance: grey,nonfibrous,homogenous Layer: 1 of 1

Lab ID #: 100644 - 09 Asbestos Present: NO Other - 100% Cust. #: HU-HM-03C No Asbestos Observed Material: Approach/Sidewalk Concrete Location:

Appearance: grey,nonfibrous,homogenous Layer: 1 of 1

For Layered Samples, each component will be analyzed and reported separately.

Robert T. Letarte Jr., Laboratory Director

Test Method EPA 40 CFR - Part 763 and/or EPA 600/R-93/116 was used to analyze the above samples. Matrix interference and/or resolution limits may yield false/negative results in certain circumstances. Suspect floor tiles containing <1% should be tested with SEM or TEM. This certificate of analysis relates only to the samples as submitted and to insure the integrity of the results, may only be reproduced in full. This certificate must not be used by the customer to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. APEX Research Inc. is not responsible for the accuracy of the results for layered samples or samples comprising multiple materials. Liability limited to cost of analysis.

NVLAP Lab Code 102118-0

(734) 449-9990, Fax (734) 449-9991 Page 3 of 23

Red Cedar Consulting Date Received: 07/25/22 P.O. Box 13216 Date Analyzed: 07/28/22 Lansing, MI 48901 Date Reported: 07/29/22

Certificate of Laboratory Analysis Test Method, Polarized Light Microscopy (PLM)

Project : 13415 S. Asher Row

Sample Information Asbestos Type/Percent Non-Asbestos Material

Lab ID #: 100644 - 10 Asbestos Present: YES Other - 98.25%

Cust. #: HU-HM-04A Chrysotile - 1.75% Material: Tan 12x12 VFT ML Location:

Appearance: brown,fibrous,homogenous POINT COUNT RESULT Layer: 1 of 4

Lab ID #: 100644 - 10a Asbestos Present: NO Other - 100% Cust. #: HU-HM-04A No Asbestos Observed Material: Glue Location:

Appearance: clear,nonfibrous,homogenous Layer: 2 of 4

Lab ID #: 100644 - 10b Asbestos Present: YES Other - 98.75% Cust. #: HU-HM-04A Chrysotile - 1.25% Material: Beige Floor Tile Location:

Appearance: beige,fibrous,homogenous POINT COUNT RESULT Layer: 3 of 4

For Layered Samples, each component will be analyzed and reported separately.

Robert T. Letarte Jr., Laboratory Director

Test Method EPA 40 CFR - Part 763 and/or EPA 600/R-93/116 was used to analyze the above samples. Matrix interference and/or resolution limits may yield false/negative results in certain circumstances. Suspect floor tiles containing <1% should be tested with SEM or TEM. This certificate of analysis relates only to the samples as submitted and to insure the integrity of the results, may only be reproduced in full. This certificate must not be used by the customer to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. APEX Research Inc. is not responsible for the accuracy of the results for layered samples or samples comprising multiple materials. Liability limited to cost of analysis.

NVLAP Lab Code 102118-0

(734) 449-9990, Fax (734) 449-9991 Page 4 of 23

Red Cedar Consulting Date Received: 07/25/22 P.O. Box 13216 Date Analyzed: 07/28/22 Lansing, MI 48901 Date Reported: 07/29/22

Certificate of Laboratory Analysis Test Method, Polarized Light Microscopy (PLM)

Project : 13415 S. Asher Row

Sample Information Asbestos Type/Percent Non-Asbestos Material

Lab ID #: 100644 - 10c Asbestos Present: NO Other - 100%

Cust. #: HU-HM-04A No Asbestos Observed Material: Mastic Location:

Appearance: black,nonfibrous,homogenous Layer: 4 of 4

Lab ID #: 100644 - 11 Asbestos Present:

Cust. #: HU-HM-04B Material: Tan 12x12 VFT ML Location: NOT ANALYZED Appearance:

Layer: 1 of 4

Lab ID #: 100644 - 11a Asbestos Present: NO Other - 100% Cust. #: HU-HM-04B No Asbestos Observed Material: Glue Location:

Appearance: clear,nonfibrous,homogenous Layer: 2 of 4

For Layered Samples, each component will be analyzed and reported separately.

Robert T. Letarte Jr., Laboratory Director

Test Method EPA 40 CFR - Part 763 and/or EPA 600/R-93/116 was used to analyze the above samples. Matrix interference and/or resolution limits may yield false/negative results in certain circumstances. Suspect floor tiles containing <1% should be tested with SEM or TEM. This certificate of analysis relates only to the samples as submitted and to insure the integrity of the results, may only be reproduced in full. This certificate must not be used by the customer to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. APEX Research Inc. is not responsible for the accuracy of the results for layered samples or samples comprising multiple materials. Liability limited to cost of analysis.

NVLAP Lab Code 102118-0

(734) 449-9990, Fax (734) 449-9991 Page 5 of 23

Red Cedar Consulting Date Received: 07/25/22 P.O. Box 13216 Date Analyzed: 07/28/22 Lansing, MI 48901 Date Reported: 07/29/22

Certificate of Laboratory Analysis Test Method, Polarized Light Microscopy (PLM)

Project : 13415 S. Asher Row

Sample Information Asbestos Type/Percent Non-Asbestos Material

Lab ID #: 100644 - 11b Asbestos Present:

Cust. #: HU-HM-04B Material: Beige Floor Tile Location: NOT ANALYZED Appearance:

Layer: 3 of 4

Lab ID #: 100644 - 11c Asbestos Present: NO Cellulose - 1% Cust. #: HU-HM-04B No Asbestos Observed Other - 99% Material: Mastic Location:

Appearance: black,nonfibrous,homogenous Layer: 4 of 4

Lab ID #: 100644 - 12 Asbestos Present:

Cust. #: HU-HM-04C Material: Tan 12x12 VFT ML Location: NOT ANALYZED Appearance:

Layer: 1 of 4

For Layered Samples, each component will be analyzed and reported separately.

Robert T. Letarte Jr., Laboratory Director

Test Method EPA 40 CFR - Part 763 and/or EPA 600/R-93/116 was used to analyze the above samples. Matrix interference and/or resolution limits may yield false/negative results in certain circumstances. Suspect floor tiles containing <1% should be tested with SEM or TEM. This certificate of analysis relates only to the samples as submitted and to insure the integrity of the results, may only be reproduced in full. This certificate must not be used by the customer to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. APEX Research Inc. is not responsible for the accuracy of the results for layered samples or samples comprising multiple materials. Liability limited to cost of analysis.

NVLAP Lab Code 102118-0

(734) 449-9990, Fax (734) 449-9991 Page 6 of 23

Red Cedar Consulting Date Received: 07/25/22 P.O. Box 13216 Date Analyzed: 07/28/22 Lansing, MI 48901 Date Reported: 07/29/22

Certificate of Laboratory Analysis Test Method, Polarized Light Microscopy (PLM)

Project : 13415 S. Asher Row

Sample Information Asbestos Type/Percent Non-Asbestos Material

Lab ID #: 100644 - 12a Asbestos Present: NO Other - 100%

Cust. #: HU-HM-04C No Asbestos Observed Material: Glue Location:

Appearance: clear,nonfibrous,homogenous Layer: 2 of 4

Lab ID #: 100644 - 12b Asbestos Present:

Cust. #: HU-HM-04C Material: Beige Floor Tile Location: NOT ANALYZED Appearance:

Layer: 3 of 4

Lab ID #: 100644 - 12c Asbestos Present: NO Other - 100% Cust. #: HU-HM-04C No Asbestos Observed Material: Mastic Location:

Appearance: black,nonfibrous,homogenous Layer: 4 of 4

For Layered Samples, each component will be analyzed and reported separately.

Robert T. Letarte Jr., Laboratory Director

Test Method EPA 40 CFR - Part 763 and/or EPA 600/R-93/116 was used to analyze the above samples. Matrix interference and/or resolution limits may yield false/negative results in certain circumstances. Suspect floor tiles containing <1% should be tested with SEM or TEM. This certificate of analysis relates only to the samples as submitted and to insure the integrity of the results, may only be reproduced in full. This certificate must not be used by the customer to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. APEX Research Inc. is not responsible for the accuracy of the results for layered samples or samples comprising multiple materials. Liability limited to cost of analysis.

NVLAP Lab Code 102118-0

(734) 449-9990, Fax (734) 449-9991 Page 7 of 23

Red Cedar Consulting Date Received: 07/25/22 P.O. Box 13216 Date Analyzed: 07/28/22 Lansing, MI 48901 Date Reported: 07/29/22

Certificate of Laboratory Analysis Test Method, Polarized Light Microscopy (PLM)

Project : 13415 S. Asher Row

Sample Information Asbestos Type/Percent Non-Asbestos Material

Lab ID #: 100644 - 13

Cust. #: HU-HM-05A Material: Brown 12x12 VFT- ML

Lab ID #: 100644 - 14 Asbestos Present: NO Other - 100% Cust. #: HU-HM-05B No Asbestos Observed Material: Brown 12x12 VFT- ML Location:

Appearance: brown,nonfibrous,homogenous Layer: 1 of 2

Lab ID #: 100644 - 14a Asbestos Present: NO Other - 100% Cust. #: HU-HM-05B No Asbestos Observed Material: Mastic Location:

Appearance: black,nonfibrous,homogenous Layer: 2 of 2

For Layered Samples, each component will be analyzed and reported separately.

Robert T. Letarte Jr., Laboratory Director

Test Method EPA 40 CFR - Part 763 and/or EPA 600/R-93/116 was used to analyze the above samples. Matrix interference and/or resolution limits may yield false/negative results in certain circumstances. Suspect floor tiles containing <1% should be tested with SEM or TEM. This certificate of analysis relates only to the samples as submitted and to insure the integrity of the results, may only be reproduced in full. This certificate must not be used by the customer to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. APEX Research Inc. is not responsible for the accuracy of the results for layered samples or samples comprising multiple materials. Liability limited to cost of analysis.

NVLAP Lab Code 102118-0 APEX Research Inc., 11054 Hi Tech Drive, Whitmore Lake, MI 48189

(734) 449-9990, Fax (734) 449-9991 Page 8 of 23

Location:

Appearance: brown,nonfibrous,homogenous Layer: 1 of 1

Other - 100%Asbestos Present: NO No Asbestos Observed

Red Cedar Consulting Date Received: 07/25/22 P.O. Box 13216 Date Analyzed: 07/28/22 Lansing, MI 48901 Date Reported: 07/29/22

Certificate of Laboratory Analysis Test Method, Polarized Light Microscopy (PLM)

Project : 13415 S. Asher Row

Sample Information Asbestos Type/Percent Non-Asbestos Material

Lab ID #: 100644 - 15 Asbestos Present: NO Other - 100%

Cust. #: HU-HM-05C No Asbestos Observed Material: Brown 12x12 VFT- ML Location:

Appearance: brown,nonfibrous,homogenous Layer: 1 of 2

Lab ID #: 100644 - 15a Asbestos Present: NO Other - 100% Cust. #: HU-HM-05C No Asbestos Observed Material: Mastic Location:

Appearance: black,nonfibrous,homogenous Layer: 2 of 2

Lab ID #: 100644 - 16 Asbestos Present: NO Cellulose - 10% Cust. #: HU-HM-06A No Asbestos Observed Fiberglass - 5% Material: White Mottled Lin.- ML Other - 85% Location:

Appearance: white,fibrous,nonhomogenous Layer: 1 of 3

For Layered Samples, each component will be analyzed and reported separately.

Robert T. Letarte Jr., Laboratory Director

Test Method EPA 40 CFR - Part 763 and/or EPA 600/R-93/116 was used to analyze the above samples. Matrix interference and/or resolution limits may yield false/negative results in certain circumstances. Suspect floor tiles containing <1% should be tested with SEM or TEM. This certificate of analysis relates only to the samples as submitted and to insure the integrity of the results, may only be reproduced in full. This certificate must not be used by the customer to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. APEX Research Inc. is not responsible for the accuracy of the results for layered samples or samples comprising multiple materials. Liability limited to cost of analysis.

NVLAP Lab Code 102118-0

(734) 449-9990, Fax (734) 449-9991 Page 9 of 23

Red Cedar Consulting Date Received: 07/25/22 P.O. Box 13216 Date Analyzed: 07/28/22 Lansing, MI 48901 Date Reported: 07/29/22

Certificate of Laboratory Analysis Test Method, Polarized Light Microscopy (PLM)

Project : 13415 S. Asher Row

Sample Information Asbestos Type/Percent Non-Asbestos Material

Lab ID #: 100644 - 16a Asbestos Present: YES Other - 98.00%

Cust. #: HU-HM-06A Chrysotile - 2.00% Material: Beige Floor Tile Location:

Appearance: beige,fibrous,homogenous POINT COUNT RESULT Layer: 2 of 3

Lab ID #: 100644 - 16b Asbestos Present: NO Other - 100% Cust. #: HU-HM-06A No Asbestos Observed Material: Glue Location:

Appearance: yellow,nonfibrous,homogenous Layer: 3 of 3

Lab ID #: 100644 - 17 Asbestos Present: NO Cellulose - 10% Cust. #: HU-HM-06B No Asbestos Observed Fiberglass - 5% Material: White Mottled Lin.- ML Other - 85% Location:

Appearance: white,fibrous,nonhomogenous Layer: 1 of 3

For Layered Samples, each component will be analyzed and reported separately.

Robert T. Letarte Jr., Laboratory Director

Test Method EPA 40 CFR - Part 763 and/or EPA 600/R-93/116 was used to analyze the above samples. Matrix interference and/or resolution limits may yield false/negative results in certain circumstances. Suspect floor tiles containing <1% should be tested with SEM or TEM. This certificate of analysis relates only to the samples as submitted and to insure the integrity of the results, may only be reproduced in full. This certificate must not be used by the customer to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. APEX Research Inc. is not responsible for the accuracy of the results for layered samples or samples comprising multiple materials. Liability limited to cost of analysis.

NVLAP Lab Code 102118-0

(734) 449-9990, Fax (734) 449-9991 Page 10 of 23

Red Cedar Consulting Date Received: 07/25/22 P.O. Box 13216 Date Analyzed: 07/28/22 Lansing, MI 48901 Date Reported: 07/29/22

Certificate of Laboratory Analysis Test Method, Polarized Light Microscopy (PLM)

Project : 13415 S. Asher Row

Sample Information Asbestos Type/Percent Non-Asbestos Material

Lab ID #: 100644 - 17a Asbestos Present:

Cust. #: HU-HM-06B Material: Beige Floor Tile Location: NOT ANALYZED Appearance:

Layer: 2 of 3

Lab ID #: 100644 - 17b Asbestos Present: NO Other - 100% Cust. #: HU-HM-06B No Asbestos Observed Material: Glue Location:

Appearance: black,nonfibrous,homogenous Layer: 3 of 3

Lab ID #: 100644 - 18 Asbestos Present: NO Cellulose - 10% Cust. #: HU-HM-06C No Asbestos Observed Fiberglass - 10% Material: White Mottled Lin.- ML Other - 80% Location:

Appearance: white,fibrous,nonhomogenous Layer: 1 of 3

For Layered Samples, each component will be analyzed and reported separately.

Robert T. Letarte Jr., Laboratory Director

Test Method EPA 40 CFR - Part 763 and/or EPA 600/R-93/116 was used to analyze the above samples. Matrix interference and/or resolution limits may yield false/negative results in certain circumstances. Suspect floor tiles containing <1% should be tested with SEM or TEM. This certificate of analysis relates only to the samples as submitted and to insure the integrity of the results, may only be reproduced in full. This certificate must not be used by the customer to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. APEX Research Inc. is not responsible for the accuracy of the results for layered samples or samples comprising multiple materials. Liability limited to cost of analysis.

NVLAP Lab Code 102118-0

(734) 449-9990, Fax (734) 449-9991 Page 11 of 23

Red Cedar Consulting Date Received: 07/25/22 P.O. Box 13216 Date Analyzed: 07/28/22 Lansing, MI 48901 Date Reported: 07/29/22

Certificate of Laboratory Analysis Test Method, Polarized Light Microscopy (PLM)

Project : 13415 S. Asher Row

Sample Information Asbestos Type/Percent Non-Asbestos Material

Lab ID #: 100644 - 18a Asbestos Present:

Cust. #: HU-HM-06C Material: Beige Floor Tile Location: NOT ANALYZED Appearance:

Layer: 2 of 3

Lab ID #: 100644 - 18b Asbestos Present: NO Other - 100% Cust. #: HU-HM-06C No Asbestos Observed Material: Glue Location:

Appearance: black,nonfibrous,homogenous Layer: 3 of 3

Lab ID #: 100644 - 19 Asbestos Present: NO Cellulose - 40% Cust. #: HU-HM-07A No Asbestos Observed Mineral Wool - 30% Material: White 1x1 Ceiling Tile, Holes Other - 30% Location:

Appearance: beige,fibrous,homogenous Layer: 1 of 2

For Layered Samples, each component will be analyzed and reported separately.

Robert T. Letarte Jr., Laboratory Director

Test Method EPA 40 CFR - Part 763 and/or EPA 600/R-93/116 was used to analyze the above samples. Matrix interference and/or resolution limits may yield false/negative results in certain circumstances. Suspect floor tiles containing <1% should be tested with SEM or TEM. This certificate of analysis relates only to the samples as submitted and to insure the integrity of the results, may only be reproduced in full. This certificate must not be used by the customer to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. APEX Research Inc. is not responsible for the accuracy of the results for layered samples or samples comprising multiple materials. Liability limited to cost of analysis.

NVLAP Lab Code 102118-0

(734) 449-9990, Fax (734) 449-9991 Page 12 of 23

Red Cedar Consulting Date Received: 07/25/22 P.O. Box 13216 Date Analyzed: 07/28/22 Lansing, MI 48901 Date Reported: 07/29/22

Certificate of Laboratory Analysis Test Method, Polarized Light Microscopy (PLM)

Project : 13415 S. Asher Row

Sample Information Asbestos Type/Percent Non-Asbestos Material

Lab ID #: 100644 - 19a Asbestos Present: YES Other - 98.25%

Cust. #: HU-HM-07A Chrysotile - 1.75% Material: Glue Pod Location:

Appearance: brown,fibrous,homogenous POINT COUNT RESULT Layer: 2 of 2

Lab ID #: 100644 - 20 Asbestos Present: NO Cellulose - 40% Cust. #: HU-HM-07B No Asbestos Observed Mineral Wool - 30% Material: White 1x1 Ceiling Tile, Holes Other - 30% Location:

Appearance: beige,fibrous,homogenous Layer: 1 of 2

Lab ID #: 100644 - 20a Asbestos Present:

Cust. #: HU-HM-07B Material: Glue Pod Location: NOT ANALYZED Appearance:

Layer: 2 of 2

For Layered Samples, each component will be analyzed and reported separately.

Robert T. Letarte Jr., Laboratory Director

Test Method EPA 40 CFR - Part 763 and/or EPA 600/R-93/116 was used to analyze the above samples. Matrix interference and/or resolution limits may yield false/negative results in certain circumstances. Suspect floor tiles containing <1% should be tested with SEM or TEM. This certificate of analysis relates only to the samples as submitted and to insure the integrity of the results, may only be reproduced in full. This certificate must not be used by the customer to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. APEX Research Inc. is not responsible for the accuracy of the results for layered samples or samples comprising multiple materials. Liability limited to cost of analysis.

NVLAP Lab Code 102118-0

(734) 449-9990, Fax (734) 449-9991 Page 13 of 23

Red Cedar Consulting Date Received: 07/25/22 P.O. Box 13216 Date Analyzed: 07/28/22 Lansing, MI 48901 Date Reported: 07/29/22

Certificate of Laboratory Analysis Test Method, Polarized Light Microscopy (PLM)

Project : 13415 S. Asher Row

Sample Information Asbestos Type/Percent Non-Asbestos Material

Lab ID #: 100644 - 21 Asbestos Present: NO Cellulose - 40%

Cust. #: HU-HM-07C No Asbestos Observed Mineral Wool - 30% Material: White 1x1 Ceiling Tile, Holes Other - 30% Location:

Appearance: beige,fibrous,homogenous Layer: 1 of 2

Lab ID #: 100644 - 21a Asbestos Present:

Cust. #: HU-HM-07C Material: Glue Pod Location: NOT ANALYZED Appearance:

Layer: 2 of 2

Lab ID #: 100644 - 22 Asbestos Present: NO Cellulose - 20% Cust. #: HU-HM-08A No Asbestos Observed Other - 80% Material: Drywall Location:

Appearance: white,fibrous,nonhomogenous Layer: 1 of 1

For Layered Samples, each component will be analyzed and reported separately.

Robert T. Letarte Jr., Laboratory Director

Test Method EPA 40 CFR - Part 763 and/or EPA 600/R-93/116 was used to analyze the above samples. Matrix interference and/or resolution limits may yield false/negative results in certain circumstances. Suspect floor tiles containing <1% should be tested with SEM or TEM. This certificate of analysis relates only to the samples as submitted and to insure the integrity of the results, may only be reproduced in full. This certificate must not be used by the customer to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. APEX Research Inc. is not responsible for the accuracy of the results for layered samples or samples comprising multiple materials. Liability limited to cost of analysis.

NVLAP Lab Code 102118-0

(734) 449-9990, Fax (734) 449-9991 Page 14 of 23

Red Cedar Consulting Date Received: 07/25/22 P.O. Box 13216 Date Analyzed: 07/28/22 Lansing, MI 48901 Date Reported: 07/29/22

Certificate of Laboratory Analysis Test Method, Polarized Light Microscopy (PLM)

Project : 13415 S. Asher Row

Sample Information Asbestos Type/Percent Non-Asbestos Material

Lab ID #: 100644 - 23 Asbestos Present: NO Cellulose - 20%

Cust. #: HU-HM-08B No Asbestos Observed Other - 80% Material: Drywall Location:

Appearance: white,fibrous,nonhomogenous Layer: 1 of 2

Lab ID #: 100644 - 23a Asbestos Present: YES Other - 98.75% Cust. #: HU-HM-08B Chrysotile - 1.25% Material: Joint Compound Location:

Appearance: beige,fibrous,homogenous POINT COUNT RESULT Layer: 2 of 2

Lab ID #: 100644 - 24 Asbestos Present: NO Cellulose - 20% Cust. #: HU-HM-08C No Asbestos Observed Other - 80% Material: Drywall Location:

Appearance: white,fibrous,nonhomogenous Layer: 1 of 2

For Layered Samples, each component will be analyzed and reported separately.

Robert T. Letarte Jr., Laboratory Director

Test Method EPA 40 CFR - Part 763 and/or EPA 600/R-93/116 was used to analyze the above samples. Matrix interference and/or resolution limits may yield false/negative results in certain circumstances. Suspect floor tiles containing <1% should be tested with SEM or TEM. This certificate of analysis relates only to the samples as submitted and to insure the integrity of the results, may only be reproduced in full. This certificate must not be used by the customer to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. APEX Research Inc. is not responsible for the accuracy of the results for layered samples or samples comprising multiple materials. Liability limited to cost of analysis.

NVLAP Lab Code 102118-0

(734) 449-9990, Fax (734) 449-9991 Page 15 of 23

Red Cedar Consulting Date Received: 07/25/22 P.O. Box 13216 Date Analyzed: 07/28/22 Lansing, MI 48901 Date Reported: 07/29/22

Certificate of Laboratory Analysis Test Method, Polarized Light Microscopy (PLM)

Project : 13415 S. Asher Row

Sample Information Asbestos Type/Percent Non-Asbestos Material

Lab ID #: 100644 - 24a Asbestos Present:

Cust. #: HU-HM-08C Material: Joint Compound Location: NOT ANALYZED Appearance:

Layer: 2 of 2

Lab ID #: 100644 - 25 Asbestos Present: NO Cellulose - 85% Cust. #: HU-HM-09A No Asbestos Observed Other - 15% Material: Cellulose Insulation Location:

Appearance: brown,fibrous,homogenous Layer: 1 of 1

Lab ID #: 100644 - 26 Asbestos Present: NO Cellulose - 85% Cust. #: HU-HM-09B No Asbestos Observed Other - 15% Material: Cellulose Insulation Location:

Appearance: brown,fibrous,homogenous Layer: 1 of 1

For Layered Samples, each component will be analyzed and reported separately.

Robert T. Letarte Jr., Laboratory Director

Test Method EPA 40 CFR - Part 763 and/or EPA 600/R-93/116 was used to analyze the above samples. Matrix interference and/or resolution limits may yield false/negative results in certain circumstances. Suspect floor tiles containing <1% should be tested with SEM or TEM. This certificate of analysis relates only to the samples as submitted and to insure the integrity of the results, may only be reproduced in full. This certificate must not be used by the customer to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. APEX Research Inc. is not responsible for the accuracy of the results for layered samples or samples comprising multiple materials. Liability limited to cost of analysis.

NVLAP Lab Code 102118-0

(734) 449-9990, Fax (734) 449-9991 Page 16 of 23

Red Cedar Consulting Date Received: 07/25/22 P.O. Box 13216 Date Analyzed: 07/28/22 Lansing, MI 48901 Date Reported: 07/29/22

Certificate of Laboratory Analysis Test Method, Polarized Light Microscopy (PLM)

Project : 13415 S. Asher Row

Sample Information Asbestos Type/Percent Non-Asbestos Material

Lab ID #: 100644 - 27 Asbestos Present: NO Cellulose - 85%

Cust. #: HU-HM-09C No Asbestos Observed Other - 15% Material: Cellulose Insulation Location:

Appearance: brown,fibrous,homogenous Layer: 1 of 1

Lab ID #: 100644 - 28 Asbestos Present: YES Other - 98.75% Cust. #: HU-HM-10A Chrysotile - 1.25% Material: Garage Window Glazing Location:

Appearance: grey,fibrous,homogenous POINT COUNT RESULT Layer: 1 of 1

Lab ID #: 100644 - 29 Asbestos Present:

Cust. #: HU-HM-10B Material: Garage Window Glazing Location: NOT ANALYZED Appearance:

Layer: of

For Layered Samples, each component will be analyzed and reported separately.

Robert T. Letarte Jr., Laboratory Director

Test Method EPA 40 CFR - Part 763 and/or EPA 600/R-93/116 was used to analyze the above samples. Matrix interference and/or resolution limits may yield false/negative results in certain circumstances. Suspect floor tiles containing <1% should be tested with SEM or TEM. This certificate of analysis relates only to the samples as submitted and to insure the integrity of the results, may only be reproduced in full. This certificate must not be used by the customer to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. APEX Research Inc. is not responsible for the accuracy of the results for layered samples or samples comprising multiple materials. Liability limited to cost of analysis.

NVLAP Lab Code 102118-0

(734) 449-9990, Fax (734) 449-9991 Page 17 of 23

Red Cedar Consulting Date Received: 07/25/22 P.O. Box 13216 Date Analyzed: 07/28/22 Lansing, MI 48901 Date Reported: 07/29/22

Certificate of Laboratory Analysis Test Method, Polarized Light Microscopy (PLM)

Project : 13415 S. Asher Row

Sample Information Asbestos Type/Percent Non-Asbestos Material

Lab ID #: 100644 - 30 Asbestos Present:

Cust. #: HU-HM-10C Material: Garage Window Glazing Location: NOT ANALYZED Appearance:

Layer: of

Lab ID #: 100644 - 31 Asbestos Present: NO Other - 100% Cust. #: HU-HM-11A No Asbestos Observed Material: Black Stair Tread Location:

Appearance: black,nonfibrous,homogenous Layer: 1 of 1

Lab ID #: 100644 - 32 Asbestos Present: NO Other - 100% Cust. #: HU-HM-11B No Asbestos Observed Material: Black Stair Tread Location:

Appearance: black,nonfibrous,homogenous Layer: 1 of 1

For Layered Samples, each component will be analyzed and reported separately.

Robert T. Letarte Jr., Laboratory Director

Test Method EPA 40 CFR - Part 763 and/or EPA 600/R-93/116 was used to analyze the above samples. Matrix interference and/or resolution limits may yield false/negative results in certain circumstances. Suspect floor tiles containing <1% should be tested with SEM or TEM. This certificate of analysis relates only to the samples as submitted and to insure the integrity of the results, may only be reproduced in full. This certificate must not be used by the customer to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. APEX Research Inc. is not responsible for the accuracy of the results for layered samples or samples comprising multiple materials. Liability limited to cost of analysis.

NVLAP Lab Code 102118-0

(734) 449-9990, Fax (734) 449-9991 Page 18 of 23

Red Cedar Consulting Date Received: 07/25/22 P.O. Box 13216 Date Analyzed: 07/28/22 Lansing, MI 48901 Date Reported: 07/29/22

Certificate of Laboratory Analysis Test Method, Polarized Light Microscopy (PLM)

Project : 13415 S. Asher Row

Sample Information Asbestos Type/Percent Non-Asbestos Material

Lab ID #: 100644 - 33 Asbestos Present: NO Other - 100%

Cust. #: HU-HM-11C No Asbestos Observed Material: Black Stair Tread Location:

Appearance: black,nonfibrous,homogenous Layer: 1 of 1

Lab ID #: 100644 - 34 Asbestos Present: NO Other - 100% Cust. #: HU-HM-12A No Asbestos Observed Material: Vinyl Window Caulk Location:

Appearance: white,nonfibrous,homogenous Layer: 1 of 1

Lab ID #: 100644 - 35 Asbestos Present: NO Other - 100% Cust. #: HU-HM-12B No Asbestos Observed Material: Vinyl Window Caulk Location:

Appearance: white,nonfibrous,homogenous Layer: 1 of 1

For Layered Samples, each component will be analyzed and reported separately.

Robert T. Letarte Jr., Laboratory Director

Test Method EPA 40 CFR - Part 763 and/or EPA 600/R-93/116 was used to analyze the above samples. Matrix interference and/or resolution limits may yield false/negative results in certain circumstances. Suspect floor tiles containing <1% should be tested with SEM or TEM. This certificate of analysis relates only to the samples as submitted and to insure the integrity of the results, may only be reproduced in full. This certificate must not be used by the customer to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. APEX Research Inc. is not responsible for the accuracy of the results for layered samples or samples comprising multiple materials. Liability limited to cost of analysis.

NVLAP Lab Code 102118-0

(734) 449-9990, Fax (734) 449-9991 Page 19 of 23

Red Cedar Consulting Date Received: 07/25/22 P.O. Box 13216 Date Analyzed: 07/28/22 Lansing, MI 48901 Date Reported: 07/29/22

Certificate of Laboratory Analysis Test Method, Polarized Light Microscopy (PLM)

Project : 13415 S. Asher Row

Sample Information Asbestos Type/Percent Non-Asbestos Material

Lab ID #: 100644 - 36 Asbestos Present: NO Other - 100%

Cust. #: HU-HM-12C No Asbestos Observed Material: Vinyl Window Caulk Location:

Appearance: white,nonfibrous,homogenous Layer: 1 of 1

Lab ID #: 100644 - 37 Asbestos Present: NO Cellulose - 90% Cust. #: HU-HM-13A No Asbestos Observed Other - 10% Material: Fiberboard Location:

Appearance: brown,fibrous,nonhomogenous Layer: 1 of 1

Lab ID #: 100644 - 38 Asbestos Present: NO Cellulose - 90% Cust. #: HU-HM-13B No Asbestos Observed Other - 10% Material: Fiberboard Location:

Appearance: brown,fibrous,nonhomogenous Layer: 1 of 1

For Layered Samples, each component will be analyzed and reported separately.

Robert T. Letarte Jr., Laboratory Director

Test Method EPA 40 CFR - Part 763 and/or EPA 600/R-93/116 was used to analyze the above samples. Matrix interference and/or resolution limits may yield false/negative results in certain circumstances. Suspect floor tiles containing <1% should be tested with SEM or TEM. This certificate of analysis relates only to the samples as submitted and to insure the integrity of the results, may only be reproduced in full. This certificate must not be used by the customer to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. APEX Research Inc. is not responsible for the accuracy of the results for layered samples or samples comprising multiple materials. Liability limited to cost of analysis.

NVLAP Lab Code 102118-0

(734) 449-9990, Fax (734) 449-9991 Page 20 of 23

Red Cedar Consulting Date Received: 07/25/22 P.O. Box 13216 Date Analyzed: 07/28/22 Lansing, MI 48901 Date Reported: 07/29/22

Certificate of Laboratory Analysis Test Method, Polarized Light Microscopy (PLM)

Project : 13415 S. Asher Row

Sample Information Asbestos Type/Percent Non-Asbestos Material

Lab ID #: 100644 - 39 Asbestos Present: NO Cellulose - 90%

Cust. #: HU-HM-13C No Asbestos Observed Other - 10% Material: Fiberboard Location:

Appearance: brown,fibrous,nonhomogenous Layer: 1 of 1

Lab ID #: 100644 - 40 Asbestos Present: YES Other - 60% Cust. #: HU-HT-01A Chrysotile - 40% Material: Light Paper Location:

Appearance: white,fibrous,nonhomogenous Layer: 1 of 1

Lab ID #: 100644 - 41 Asbestos Present:

Cust. #: HU-HT-01B Material: Light Paper Location: NOT ANALYZED Appearance:

Layer: of

For Layered Samples, each component will be analyzed and reported separately.

Robert T. Letarte Jr., Laboratory Director

Test Method EPA 40 CFR - Part 763 and/or EPA 600/R-93/116 was used to analyze the above samples. Matrix interference and/or resolution limits may yield false/negative results in certain circumstances. Suspect floor tiles containing <1% should be tested with SEM or TEM. This certificate of analysis relates only to the samples as submitted and to insure the integrity of the results, may only be reproduced in full. This certificate must not be used by the customer to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. APEX Research Inc. is not responsible for the accuracy of the results for layered samples or samples comprising multiple materials. Liability limited to cost of analysis.

NVLAP Lab Code 102118-0