About this file

This document contains three pages of technical drawings for an X5000 450kV cargo scanning system. The drawings provide details on system specifications, scanning envelopes, turntable dimensions and travel distances, virtual detector sizes, power requirements, and modular space requirements. The related federal contract opportunity is a solicitation from the Department of the Army seeking rigging services for the installation and setup of an X-ray cargo scanning system at Rock Island Arsenal in Illinois. The solicitation number is W519TC23QRIGG.

View the file

Other files for this federal contract opportunity

Other files attached to RIGGING SERVICES (XRAY) CRANE, IN, newest first.
File Type Posted
AMENDMENT 02.docx DOCX document
Amendment 02 - Pricing Sheet.xlsx XLSX spreadsheet
Attachment 01 PWS dtd changes 31 Aug 23.docx DOCX document
Attachment 07 NSI X5000 XRAY 450KV INSTALLATION GUJIDE.pdf PDF
Attachment 05 FAR 52-212-3-Offeror-Representations-and-Certifications.pdf PDF
Attachment 02 Pricing Sheet.xlsx XLSX spreadsheet
Attachment 06 FAR 52-204-24 Full Text Provision Certification.pdf PDF
Attachment 04 52-212-5-Contract-Terms-and-Conditions-.docx DOCX document
Attachment 03 15-4821 (1) Rev 24 dated 30JUN2023.pdf PDF
Attachment 01 PWS dtd 15 Aug 23.docx DOCX document

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DOOR

OPENING

DOOR

OPENING

B

POWER REQUIREMENTS 230/240 VAC,

60 AMP, SINGLE PHASE, 50/60Hz DISCONNECT W/IN 15 FEET [4.5 m]

DEDICATED GROUND ROD OR

EQUIVALENT

SERVICE

AREA

REQUIRED

EXAMPLE PLACEMENT ONLY -

ACTUAL PLACEMENT DEPENDENT

ONLY ON CABLE LENGTH NOTED.

CABLE ENTRY POINT

CABLE LENGTH:

10 METERS

FROM ENTRY

POINT

B

TOUCH SCREEN

EMERGENCY STOP

ERGO CHAIR

MODELS CAN VARY

SEE QUOTATION FOR

OPTIONS ON MONITORS/ERGO

DESK AND ERGO CHAIR

X5500 SHOWN2

B

NOTE:

NOTED ITEMS MAY NOT BE REQUIRED - (SHOWN IS A DUAL SOURCE SYSTEM)1.

X5500 SYSTEM INCLUDES: ELECTRICAL CABINET (60x13 in) REQUIRING 60x36 in 2.

SERVICE AREA, HMI, 450 I/O BOX, ONE ACCESS DOOR MOTION SAFETY

SWITCH, PREWARN MODULE ~ 3 M (10 FT.) FROM MANIPULATOR; CABLE

LENGTH FROM MANIPULATOR TO ELECTRICAL CABINET ~ 6 FT. [1.83 m]

CABLE LENGTHS APPROX 5 METERS FROM ENTRANCE POINT3.

DIMENSIONS FOR LAYOUT ARE APPROXIMATE ONLY SHOWN IS A MINIMUM 4.

"SPACE LAYOUT"

DIMENSIONS SHOWN WITH [ ] ARE IN MILLIMETERS5.

WEIGHT OF CABINET WITH MANIPULATOR:

APPROX 27500 - 30200 lb (12500-13700 kg.)

B

WEIGHT OF MANIPULATOR:

APPROX 3000 - 4200 lb (1360 - 1900 kg.)

B

REVISIONS

REV. DESCRIPTION DATE ENG

A ECO# 162085, INITIAL RELEASE 06-15-2020 GMT

B ECO# 162222, INITIAL RELEASE 08-31-2021 GMT

X5000 450kV SYSTEM- SPECIFICATIONS

THE INFORMATION CONTAINED HEREIN IS

PROPREITARY TO NORTH STAR IMAGING, INC.

AND SHALL NOT BE REPRODUCED OR

DISCLOSED IN WHOLE OR IN PART, NOR USED

FOR ANY DESIGN OR MANUFACTURING

PURPOSES UNLESS AUTHORIZED IN WRITING

BY NORTH STAR IMAGING, INC.

(763) 463-5650

(800) 635-8392

(763) 463-5651

SURFACE ROUGHNESS

UNLESS OTHERWISE

SPECIFIED REMOVE ALL

BURRS AND BREAK SHARP

EDGES .02 MAX.

ALL DIMENSIONING AND

TOLERANCING IN

ACCORDANCE WITH LATEST

ANSI Y14.5 STANDARD

ANGULAR ±1°

.X ±.020 .XXX ± .005

.XX ± .010 .XXXX ± .0005

TOLERANCES

ALL DIMENSIONS ARE IN INCHES

UNLESS OTHERWISE SPECIFIED

05-20-2020

MATERIAL:

FINISH:

Material <not specified>

DESIGNER:

N. Wilson

DO NOT SCALE DRAWING

THIRD ANGLE

PROJECTION

DATE:

PROPRIETARY AND CONFIDENTIAL

DECIMAL

B

SCALE: 1:36

SIZE DWG. NO.

B

REV.

SHEET 1 OF 3WEIGHT:

TITLE

19875 S. DIAMOND LAKE ROAD

ROGERS, MINNESOTA 55374

PHONE:

TOLL FREE:

FAX:

WWW.4NSI.COM

X5000-2020 450kV SYSTEM 33386.22220

MAX. VIRTUAL

DETECTOR WIDTH

MAX. VIRTUAL

DETECTOR HEIGHT

DEFINITION OF COORDINATE AXES

TURNTABLE (9 INCH [228] SHOWN)

CONTINUOUS ROTATION

X AXIS

Z AXIS

Y AXIS

93.9

+20°

-20°

MAX. TURNTABLE TRAVEL

MAX. FOCAL DISTANCE

11.8

INTERNAL

TABLE

TRAVEL

23.4

TURNTABLE TRAVEL

EXTENDS TO DOORWAY

FOR PART LOADING

B

NOTES:

MAXIMUM TURNTABLE TRAVEL DISTANCES ARE WITH THE 1.

TURNTABLE BELOW THE X-RAY SOURCE AND DETECTOR.

ALL TRAVEL DISTANCES DEPEND ON CONFIGURATION 2.

OF SOURCE AND DETECTOR. SEE "X5000 SCANNING

ENVELOPE" FOR DETAILS.

B

X5000 450kV SYSTEM- SPECIFICATIONS

THE INFORMATION CONTAINED HEREIN IS

PROPREITARY TO NORTH STAR IMAGING, INC.

AND SHALL NOT BE REPRODUCED OR

DISCLOSED IN WHOLE OR IN PART, NOR USED

FOR ANY DESIGN OR MANUFACTURING

PURPOSES UNLESS AUTHORIZED IN WRITING

BY NORTH STAR IMAGING, INC.

(763) 463-5650

(800) 635-8392

(763) 463-5651

SURFACE ROUGHNESS

UNLESS OTHERWISE

SPECIFIED REMOVE ALL

BURRS AND BREAK SHARP

EDGES .02 MAX.

ALL DIMENSIONING AND

TOLERANCING IN

ACCORDANCE WITH LATEST

ANSI Y14.5 STANDARD

ANGULAR ±1°

.X ±.020 .XXX ± .005

.XX ± .010 .XXXX ± .0005

TOLERANCES

ALL DIMENSIONS ARE IN INCHES

UNLESS OTHERWISE SPECIFIED

05-20-2020

MATERIAL:

FINISH:

Material <not specified>

DESIGNER:

N. Wilson

DO NOT SCALE DRAWING

THIRD ANGLE

PROJECTION

DATE:

PROPRIETARY AND CONFIDENTIAL

DECIMAL

B

SCALE: 1:20

SIZE DWG. NO.

B

REV.

SHEET 2 OF 3WEIGHT:

TITLE

19875 S. DIAMOND LAKE ROAD

ROGERS, MINNESOTA 55374

PHONE:

TOLL FREE:

FAX:

WWW.4NSI.COM

X5000-2020 450kV SYSTEM

MIN

MIN

MIN

MIN

MIN

MIN

MINO

PT

IO

N

A

OPTION B

O

PT

IO

N

C

MIN

NOTES:

CEILING HEIGHT MINIMUM = 108 IN1

DOOR WIDTH MINIMUM = 30 INCHES 2.

(MUST BE LOCATED IN ONE OF THE

LOCATIONS SHOWN: OPTIONS A, B, C)

ELEVATOR OR PASSAGE WAY MUST FIT 3.

RIGGING BEAM = 12 FT X 4 IN X 4 IN

MINIMUM MODULAR SPACE REQUIREMENTS

X5000 450kV SYSTEM- SPECIFICATIONS

THE INFORMATION CONTAINED HEREIN IS

PROPREITARY TO NORTH STAR IMAGING, INC.

AND SHALL NOT BE REPRODUCED OR

DISCLOSED IN WHOLE OR IN PART, NOR USED

FOR ANY DESIGN OR MANUFACTURING

PURPOSES UNLESS AUTHORIZED IN WRITING

BY NORTH STAR IMAGING, INC.

(763) 463-5650

(800) 635-8392

(763) 463-5651

SURFACE ROUGHNESS

UNLESS OTHERWISE

SPECIFIED REMOVE ALL

BURRS AND BREAK SHARP

EDGES .02 MAX.

ALL DIMENSIONING AND

TOLERANCING IN

ACCORDANCE WITH LATEST

ANSI Y14.5 STANDARD

ANGULAR ±1°

.X ±.020 .XXX ± .005

.XX ± .010 .XXXX ± .0005

TOLERANCES

ALL DIMENSIONS ARE IN INCHES

UNLESS OTHERWISE SPECIFIED

06-12-2020

MATERIAL:

FINISH:

Material <not specified>

DESIGNER:

N. Wilson

DO NOT SCALE DRAWING

THIRD ANGLE

PROJECTION

DATE:

PROPRIETARY AND CONFIDENTIAL

DECIMAL

B

SCALE: 1:20

SIZE DWG. NO.

B

REV.

SHEET 3 OF 3WEIGHT:

TITLE

19875 S. DIAMOND LAKE ROAD

ROGERS, MINNESOTA 55374

PHONE:

TOLL FREE:

FAX:

WWW.4NSI.COM

X5000-2020 450kV SYSTEM

Sheet1
Drawing View2
Drawing View3
Drawing View6
Drawing View12
Sheet2
Drawing View7
Drawing View8
Drawing View9
Sheet3
Drawing View10
Drawing View11

File details come from the government source that posted it. Updated .