This document provides details on a federal contract opportunity to rehabilitate Cedar Pass Cottage in Badlands National Park. The solicitation number is 140P6322B0002 and seeks to rehabilitate Cedar Pass Cottage for the National Park Service Midwest Region. Attached is a PDF of related drawings. The opportunity type is a solicitation to rehabilitate the property. No further details are provided on response dates, pricing terms, or other requirements.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SOUTH DAKOTA
SOUTHWESTERN
V.C.
HQ.
LEGEND
BADLANDS NATIONAL PARK
SCALE OF
MILES
20 0 20
TRAIL
CAMPGROUND
PICNIC AREA
AMPHITHEATER
RANGER STATION
PARK HEADQUARTERS
VISITOR CENTER
CREEK OR RIVER
FIRST AID
WILDERNESS AREA
UNPAVED ROAD
COUNTY LINE
PARK BOUNDARY
PAVED ROAD
STATE LINE
RIDGE
PINE
RESERVATION
RESERVATION
PINE
RIDGE
S A G E
L O O P
RD.
RIM R
D
CREEK
B A D L A N D S
SPRINGS
FOURCHE
SPEARFISH
HOT
BELLE
RIDGE
PINE
NEBRASKA
SOUTH
DAKOTA
WHIT
E
RIVE
R
MISSION
85 FAITH
STURGIS
C H E Y E N N E
RIV
ER
WALL 14
MURDO
OAHE
LAKE
FEE STATION
INTERIOR
STRONGHOLD
RIVER
WHITE
V.C.
UNIT
AREA
CREEK
PALMER
NORTH
UNIT
FEE STATION
PINNACLES
CEDAR PASS
LODGE
V.C.
PASS
CEDAR
HQ.
FEE STATION
NORTHEAST
BEN
REIFEL
PARK
NATIONAL
BADLANDS
SHIRT
RED
SHANNON COUNTY
PENNINGTON COUNTY
KNEE
WOUNDED
TO
J A C K S O N
C O U N T Y
S H A N N O N
C O U N T Y
W H
IT
E
R
IV
E R
TO
HERMOSA
TO
C U S
TE
R
C O U N
TY
P E N N
IN
G
TO
N
C O U N
TY
SCENIC
C H E Y E N N E
R
IV
E R
WALL
CITY
RAPID
TO
TO
PIERRE
KADOKA
J A C K S O N
C O U N T Y
P E N N
IN
G T O N
C O U N T Y
FLAT
CACTUS
INTERIOR
TO
CITY
RAPID
1044 North 115th Street | Suite 300
Omaha, NE 68154
(402) 493-4800 www.schemmer.com
REVISED TITLE OF SHEET DRAWING NO.
SHEET
PMIS / PKG. NO.
OF
SUB SHEET NO.
ARCH/ENG PROJ #
DESIGNED
DRAWN
CHECKED
PREPARED
DATE
227763 / 80111
177740
C U s e rs \b b e n tz in g e r\ D o c u m e n ts \0
-A
R C
H
R b ill
H
P G
.r v t
RJM
WEB
PJB
01/28/2022
07310.022
COVER SHEET
07310022- 0- 0 COVER SHEET
REHAB CEDAR PASS COTTAGE
CEDAR PASS LODGE
20681 SD-240, INTERIOR, SD 57750
CIVIL
C000
GENERAL
0 COVER SHEET
ACC01 ARCHITECTURAL CODE COMPLIANCE
STRUCTURAL
S 00 STRUCTURAL INFO SHEET
S 01 STRUCTURAL NOTES
S101 FOUNDATION PLAN & FRAMING PLANS
S201 TYPICAL FOUNDATION DETAILS
S202 TYPICAL FRAMING DETAILS
S203 DETAILS
S204 DETAILS
DRAWING INDEX
MECHANICAL
M 00 MECHANICAL INFO SHEET
M001 DEMOLITION FLOOR PLAN - MECHANICAL
M101 FLOOR PLAN - MECHANICAL
PLUMBING
P 00 PLUMBING INFO SHEET
P001 DEMOLITION FLOOR PLAN - PLUMBING
P101 FLOOR PLAN - PLUMBING
P301 DETAILS & SCHEDULES - PLUMBING
C000 TOPOGRAPHIC SURVEY
CO01 SITE DEMOLITION PLAN
C101 SITE LAYOUT & PAVING PLAN
C102 SITE GRADING & DRAINAGE PLAN
C201 SITE DETAILS
FINAL CD
FIRE PROTECTION
FP 00 FIRE PROTECTION INFO SHEET
FP101 FLOOR PLAN - FIRE PROTECTION
ARCHITECTURAL
A 00 ARCHITECTURAL INFO SHEET
A 000 ARCHITECTURAL INFO SHEET
A001 DEMOLITION FLOOR PLANS
A002 DEMOLITION REFLECTED CEILING PLAN & ROOF
A003 DEMOLITION PANEL PLAN
A004 DEMOLITION EXISTING CONDITIONS EXTERIOR
A005 DEMOLITION EXISTING CONDITIONS INTERIOR
A101 FLOOR PLAN, ROOF PLAN
A201 EXTERIOR BUILDING ELEVATIONS
A202 BUILDING SECTIONS
A301 SCHEDULES, DOOR AND WINDOW DETAILS
A302 DOOR & WINDOW DETAILS
A303 ROOM SCHEDULE, MATERIAL NOTES
A401 WALL SECTIONS, DETAILS
A501 MOUNTING HEIGHTS, INTERIOR ELEVATIONS &
DETAILS
A601 REFLECTED CEILING PLANS AND DETAILS
ELECTRICAL
E 00 ELECTRICAL INFO SHEET
E101 ELECTRICAL FLOOR PLANS
E201 ELECTRICAL DETAILS AND SCHEDULES
DATE INITIAL
PROJECT LOCATION
1/28/22
ELECTRICAL ENGINEER
1/28/2022
STRUCTURAL ENGINEER
1/28/2022
CIVIL ENGINEER
1/28/22
MECHANICAL ENGINEER
-B
REF.
-A
100-C
104-B
-B
100-A
-B
DW
108-A 1
-B
F E
B
E
OCCUPANCY CLASSIFICATION
RESIDENTIAL (R-1)
LIVING
CLST
BEDROOM 1
CLST
HALL
CLST
BATH
BEDROOM 2
UTIL
ENTRY
109CLST
KITCHEN
EXIT PATH: 37'-7"
2-A RATED SINGLE FIRE
EXTINGUISHER FOR LIGHT
(LOW) HAZARD OCCUPANCY.
BRACKET MOUNTED.
1044 North 115th Street | Suite 300
Omaha, NE 68154
(402) 493-4800 www.schemmer.com
REVISED TITLE OF SHEET DRAWING NO.
SHEET
PMIS / PKG. NO.
OF
SUB SHEET NO.
ARCH/ENG PROJ #
DESIGNED
DRAWN
CHECKED
PREPARED
DATE
227763 / 80111
177740
C U s e rs \b b e n tz in g e r\ D o c u m e n ts \0
-A
R C
H
R b ill
H
P G
.r v t
WEB
WEB
PJB
01/28/2022
07310.022
ACC01
ARCHITECTURAL CODE
COMPLIANCE
07310022- 0- ACC01 ARCHITECTURAL CODE COMPLIANCE
REHAB CEDAR PASS COTTAGE
CEDAR PASS LODGE
20681 SD-240, INTERIOR, SD 57750
XX FIRE BARRIER (X HOURS)
XX FIRE PARTITION (X HOURS)
XX SMOKE BARRIER (X HOURS)
XX SMOKE PARTITION (X
HOURS)
XX BUILDING SEPARATION
(X HOURS)
CODE COMPLIANCE
LEGEND
NUMBER OF OCCUPANTS
PER ROOM
DEAD-END DISTANCE
XXX'-XX"
NEW FIRE EXTINGUISHER-
INSIDE RECESSED
CABINET -(FE1)
75'
NOTES:
• CONTRACTOR SHALL PROVIDE PERMANENT
SIGNAGE OR STENCILING WITHIN CEILING
PLENUM AT ALL FIRE RATED WALLS, SMOKE
BARRIERS & SMOKE PARTITIONS. LETTERING
SHALL BE AT LEAST 1/2" IN HEIGHT WITH THE
WORDING: "FIRE AND/OR SMOKE BARRIER -
PROTECT ALL OPENINGS:. REPEAT AT
INTERVALS NOT EXCEEDING 30'-0" MEASURED
HORIZONTALLY ALONG THE PARTITION WALL.
• SEAL PENETRATIONS IN FIRE RATED SMOKE
BARRIERS, FIRE RATED BARRIERS & SMOKE
BARRIERS.
COMMON PATH DISTANCE
XXX'-XX"
OCCUPANCY ALONG PATH
ACCESSORY OCCUPANCY
INCIDENTAL OCCUPANCY
NOT HABITABLE
OCCUPANCY
CODE SUMMARY
APPLICABLE CODES
BUILDING :
ACCESSIBILITY :
LIFE SAFETY :
ENERGY :
MECHANICAL :
PLUMBING :
ELECTRICAL :
OCCUPANCY GROUP :
TYPE OF CONSTRUCTION :
MAXIMUM ALLOWED HEIGHT
MAXIMUM ALLOWED AREA
MIXED USE SEPARATIONS :
HEIGHT AND AREA LIMITS
FIRE SEPARATION ASSEMBLIES
EXITS
SHAFTS / HOISTWAYS
DWELLING UNIT SEPARATIONS
INTERIOR LOAD BEARING
WALLS, COLUMNS, FRAMING
ROOF CONSTRUCTION
FLOOR CONSTRUCTION
FIRE WALLS
EXTERIOR WALL OPENING LIMITS :
DRAFTSTOPS :
FIRE PROTECTIVE SYSTEMS
AUTO FIRE SUPPRESSION :
STANDPIPE :
FIRE ALARM SYSTEM :
AUTO FIRE DETECTION :
SMOKE DETECTION :
FIRE RESISTANCE OF STRUCTURAL
ELEMENTS
RATING
(HOURS)
DESIGN
NUMBER
EXTERIOR WALLS
LOAD BEARING WALLS
NON-LOAD BEARING WALLS
CALCULATIONS
DOOR
STAIR
R-1
V-B
120'
50,000 SF
1 HR
2015 ABAAS
NA
NFPA 13D
NA
NFPA 72
NFPA 13
NFPA 72
2009 NFPA 101
2018 IECC
2018 IMC
2021 UPC
2020 NEC
2021 IBC / 2021 IEBC
UL
UL
UL
UL
UL
UL
UL
UL
UL
-.-" / OCC
-.-" / OCC
PLUMBING FIXTURE
REQUIREMENTS
MEN - REQUIRED
WOMEN - REQUIRED
MEN - PROVIDED
WOMEN - PROVIDED
NUMBER OF OCCUPANTS
MEN
WOMEN
WC LAV URINALS
TUB/
SHOWER
DRINKING FOUNTAINS
REQUIRED
PROVIDED
OCC TYPE
1 PER 50 2 PER 50 - - 1 PER 8
1 PER 100
FIRST FLOOR
SECOND FLOOR
TOTAL
AREA (GROSS SQUARE FOOTAGE) :
BUILDING STATISTICS
NUMBER OF STORIES :
THIRD FLOOR
FOURTH FLOOR
SUBGRADE
1091 SF
0 SF
1091 SF
0 SF
0 SF
0 SF
ACC_ROOM SCHEDULE
ROOM NO ROOM NAME FUNCTION OF SPACE CALC (SQF/OCC) OCCUPANT LOAD
AREA / OCC
FIRST FLOOR
RESIDENTIAL (R-1)
100 LIVING 337 SF
101 CLST 6 SF
102 BEDROOM 1 143 SF
103 CLST 10 SF
104 HALL 54 SF
105 CLST 8 SF
106 BATH 61 SF
107 BEDROOM 2 122 SF
108 UTIL 14 SF
109 ENTRY 16 SF
110 CLST 11 SF
111 KITCHEN 159 SF
: 12 0
RESIDENTIAL (R-1): 12 0
FIRST FLOOR: 12 0
TOTALS:: 12 0
SCALE: 1/4" = 1'-0"
FIRST FLOOR - CODE REVIEW PLAN
1091 SF GROSS
NORTH
DATE INITIAL
1044 North 115th Street | Suite 300 Omaha, NE 68154
(402) 493-4800 www.schemmer.com
REVISED TITLE OF SHEET DRAWING NO.
SHEET
PMIS / PKG. NO.
OF
SUB SHEET NO.
ARCH/ENG PROJ #
DESIGNED
DRAWN
CHECKED
PREPARED
DATE
DATE INITIAL
REHAB CEDAR PASS COTTAGE
CEDAR PASS LODGE
20681 SD-240, INTERIOR, SD 57750
227763 / 80111
177740
07310.022
01/28/2022 42
WJ TOPOGRAPHIC SURVEY
C000
(402) 493-4800 www.schemmer.com
REVISED TITLE OF SHEET DRAWING NO.
SHEET
PMIS / PKG. NO.
OF
SUB SHEET NO.
ARCH/ENG PROJ #
DESIGNED
DRAWN
CHECKED
PREPARED
DATE
DATE INITIAL
REHAB CEDAR PASS COTTAGE
CEDAR PASS LODGE
20681 SD-240, INTERIOR, SD 57750
227763 / 80111
177740
07310.022
01/28/2022 42
MJS
DJK SITE DEMOLITION PLAN
C0011044 North 115th Street | Suite 300
Omaha, NE 68154
(402) 493-4800 www.schemmer.com
REVISED TITLE OF SHEET DRAWING NO.
SHEET
PMIS / PKG. NO.
OF
SUB SHEET NO.
ARCH/ENG PROJ #
DESIGNED
DRAWN
CHECKED
PREPARED
DATE
DATE INITIAL
REHAB CEDAR PASS COTTAGE
CEDAR PASS LODGE
20681 SD-240, INTERIOR, SD 57750
227763 / 80111
177740
07310.022
01/28/2022 42
MJH
1/28/2022
(402) 493-4800 www.schemmer.com
REVISED TITLE OF SHEET DRAWING NO.
SHEET
PMIS / PKG. NO.
OF
SUB SHEET NO.
ARCH/ENG PROJ #
DESIGNED
DRAWN
CHECKED
PREPARED
DATE
DATE INITIAL
REHAB CEDAR PASS COTTAGE
CEDAR PASS LODGE
20681 SD-240, INTERIOR, SD 57750
227763 / 80111
177740
07310.022
01/28/2022 42
MJS
DJK
C101
SITE LAYOUT & PAVING
PLAN
(402) 493-4800 www.schemmer.com
REVISED TITLE OF SHEET DRAWING NO.
SHEET
PMIS / PKG. NO.
OF
SUB SHEET NO.
ARCH/ENG PROJ #
DESIGNED
DRAWN
CHECKED
PREPARED
DATE
DATE INITIAL
REHAB CEDAR PASS COTTAGE
CEDAR PASS LODGE
20681 SD-240, INTERIOR, SD 57750
227763 / 80111
177740
07310.022
01/28/2022 42
MJS
DJK
C102
SITE GRADING & DRAINAGE
PLAN
(402) 493-4800 www.schemmer.com
REVISED TITLE OF SHEET DRAWING NO.
SHEET
PMIS / PKG. NO.
OF
SUB SHEET NO.
ARCH/ENG PROJ #
DESIGNED
DRAWN
CHECKED
PREPARED
DATE
DATE INITIAL
REHAB CEDAR PASS COTTAGE
CEDAR PASS LODGE
20681 SD-240, INTERIOR, SD 57750
227763 / 80111
177740
07310.022
01/28/2022 42
MJS
DJK
MJH C201
SITE DETAILS
(402) 493-4800 www.schemmer.com
REVISED TITLE OF SHEET DRAWING NO.
SHEET
PMIS / PKG. NO.
OF
SUB SHEET NO.
ARCH/ENG PROJ #
DESIGNED
DRAWN
CHECKED
PREPARED
DATE
227763 / 80111
177740
C U s e rs \b b e n tz in g e r\ D o c u m e n ts \0
-A
R C
H
R b ill
H
P G
.r v t
PJB
WEB
PJB
01/28/2022
07310.022
A 00
ARCHITECTURAL INFO SHEET
07310022- 2- A 00 ARCHITECTURAL INFO SHEET
REHAB CEDAR PASS COTTAGE
CEDAR PASS LODGE
20681 SD-240, INTERIOR, SD 57750
0 COVER SHEET
ACC01 ARCHITECTURAL CODE
COMPLIANCE
A 00 ARCHITECTURAL INFO SHEET
A 000 ARCHITECTURAL INFO SHEET
A001 DEMOLITION FLOOR PLANS
A002 DEMOLITION REFLECTED CEILING
PLAN & ROOF
A003 DEMOLITION PANEL PLAN
A004 DEMOLITION EXISTING
CONDITIONS EXTERIOR
A005 DEMOLITION EXISTING
CONDITIONS INTERIOR
A101 FLOOR PLAN, ROOF PLAN
A201 EXTERIOR BUILDING ELEVATIONS
A202 BUILDING SECTIONS
A301 SCHEDULES, DOOR AND WINDOW
DETAILS
A302 DOOR & WINDOW DETAILS
A303 ROOM SCHEDULE, MATERIAL
NOTES
A401 WALL SECTIONS, DETAILS
A501 MOUNTING HEIGHTS, INTERIOR
ELEVATIONS & DETAILS
A601 REFLECTED CEILING PLANS AND
DETAILS
A. THE DEMOLITION PLANS WERE PRODUCED BY DUPLICATING THE ORIGINAL
DRAWINGS PROVIDED BY THE OWNER AND LIMITED FIELD VERIFICATION.
DIMENSIONS AND EXISTING CONDITIONS ARE APPROXIMATE. CONTRACTOR
SHALL FIELD VERIFY EXISTING CONDITIONS. ITEMS WHICH ARE INTENDED
TO BE REMOVED, RELOCATED, OR SALVAGED ARE SHOWN AS FULL-TONE
DASHED LINES AND ARE LISTED IN THE REFERENCED DEMOLITION NOTES.
ALL OTHER ITEMS ARE INTENDED TO REMAIN IN PLACE AND ARE SHOWN
HALF-TONE.
B. DEMOLITION SHALL INCLUDE, BUT IS NOT LIMITED TO, THE ITEMS BELOW OR
HERE-IN. THE CONTRACTOR SHALL COORDINATE ALL REQUIRED
RENOVATION AND NEW CONSTRUCTION WITH THE EXISTING BUILDING TO
IDENTIFY THE TOTAL EXTENT OF THE DEMOLITION REQUIRED AND AS LISTED
BELOW.
C. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE DEMOLITION AND
REMOVAL OF ALL EXISTING BUILDING COMPONENTS, MATERIALS,
EQUIPMENT, AND APPURTENANCES AS REQUIRED TO BUILD, ERECT,
INSTALL, OR ACCOMMODATE ALL NEW CONSTRUCTION WITH THE OWNER
HAVING FIRST RIGHT OF REFUSAL ON ALL ITEMS.
D. ITEMS NOTED TO BE REMOVED AND SALVAGED OR REINSTALLED SHALL BE
CAREFULLY REMOVED BY THE CONTRACTOR WITHOUT DAMAGE AND
STORED OR REINSTALLED ON THE SITE AS DIRECTED. REMOVED AND
SALVAGED ITEMS SHALL REMAIN THE PROPERTY OF THE OWNER.
E. WHERE EXISTING FLOOR MATERIALS AND/OR WALLS ARE TO BE REMOVED,
PREP REMAINING FLOOR AND/OR WALL SUBSTRATE AS REQUIRED PER
MANUFACTURERS RECOMMENDATIONS FOR THE NEW FLOOR/WALL FINISH
MATERIAL. REMOVE ALL FINISH FLOORING DOWN TO BASE SUBSTRATE
FLOORING AND PREP TO RECEIVE NEW FINISH.
F. THE CONTRACTOR IS RESPONSIBLE FOR THE ERECTION, MAINTENANCE,
AND REMOVAL OF ALL CONSTRUCTION BARRIERS.
G. TEMPORARILY SHORE AND BRACE STRUCTURE AT ALL BEARING WALL
DEMOLITION LOCATIONS UNTIL NEW PERMANENT STRUCTURE IS
ESTABLISHED. SEE STRUCTURAL.
H. REMOVE EXISTING ELEMENTS/FINISHES NOT REQUIRED IN THE COMPLETED
PROJECT, BUT CONFLICTING WITH NEW FINISHES. THESE
ELEMENTS/FINISHES SHALL INCLUDE, BUT ARE NOT LIMITED TO THE ITEMS
LISTED BELOW:
1. ALL EXISTING WALLS, DOORS, FRAMES, AND WINDOWS SHOWN ON THE
PLAN AS A FULL-TONE DASHED LINE ARE TO BE REMOVED.
I. SEE STRUCTURAL, MECHANICAL, AND ELECTRICAL DRAWINGS FOR
ADDITIONAL DEMOLITION, INCLUDING, BUT NOT LIMITED TO, ALL CONCRETE
SLAB REMOVAL AND REPLACEMENT.
J. REFER TO MECHANICAL DEMOLITION PLANS FOR ADDITIONAL DEMOLITION
REQUIRED TO ACCOMMODATE NEW MECHANICAL PIPING AND ASSOCIATED
EQUIPMENT.
K. SEE CIVIL DRAWINGS FOR EXTENT OF SITE DEMOLITION WORK.
A. EXISTING CONDITIONS ARE BASED ON DRAWINGS PROVIDED BY THE OWNER
AND LIMITED FIELD VERIFICATION. THE CONTRACTOR SHALL FIELD VERIFY
ALL EXISTING CONDITIONS AND DIMENSIONS AND NOTIFY THE
ARCHITECT/ENGINEER OF ANY DISCREPANCIES OR VARIATIONS FROM
THOSE SHOWN ON THE DRAWINGS. THE CONTRACTOR SHALL ADJUST TO
ACTUAL FIELD CONDITIONS.
B. CONTRACTOR SHALL TAKE ALL MEASUREMENTS FOR WORK AND BE
RESPONSIBLE FOR SAME. CONTRACTOR SHALL ADJUST FOR ACTUAL FIELD
CONDITIONS. COORDINATE THE WORK AND SHOP DRAWINGS WITH ALL
OTHER TRADES AFFECTED.
C. SCREENED HALF-TONE LINES INDICATE EXISTING CONSTRUCTION TO
REMAIN. FULL-TONE LINES INDICATE NEW OR RELOCATED CONSTRUCTION.
D. BUILDING ELEVATION 2437.0' ON THE SITE PLAN EQUALS ELEVATION 100'-0"
ON THE ARCHITECTURAL PLANS.
E. DIMENSIONS ARE TYPICALLY TO FINISH FACE OF MASONRY, CONCRETE,
GYPSUM WALL BOARD, AND METAL FRAMES; OR CENTER LINE OF COLUMN
OR BEAMS, UNLESS NOTED OTHERWISE.
F. INTERIOR DOORS WITH THE HINGE-SIDE SHOWN CLOSE TO CORNERS SHALL
BE LOCATED 4 INCHES FROM ADJACENT WALL UNLESS NOTED OTHERWISE
G. CHANGES IN FLOOR MATERIALS SHALL OCCUR UNDER DOORS.
a. PROVIDE POSITIVE DRAINAGE TO ALL ROOMS WITH NEW FLOOR DRAINS
H. ALL ANGLES ON THE FLOOR PLANS ARE 45 OR 90 DEGREES UNLESS
OTHERWISE INDICATED.
I. PROVIDE FIRE TREATED 2x6 OR LARGER WOOD BLOCKING IN WALLS AND
FURRING SPACES AS REQUIRED FOR MOUNTING OF ALL WALL SUPPORTED
ITEMS. WHETHER OR NOT DETAILED ON THE DRAWINGS, THE DRYWALL
CONTRACTOR SHALL COORDINATE AND INSTALL ALL STIFFENERS, BRACING,
BACK-UP PLATES, AND SUPPORTING BRACKETS AS REQUIRED FOR THE
INSTALLATION OF CASEWORK AND WALL MOUNTED OR SUSPENDED
MECHANICAL, ELECTRICAL, OR MISCELLANEOUS EQUIPMENT. THESE ITEMS
INCLUDE, BUT ARE NOT LIMITED TO, HANDRAIL BRACKETS, DOOR WALL
STOPS, FIRE EXTINGUISHER CABINETS, VANITY TOPS, BASE AND WALL
CABINETS, COUNTERTOPS, CONTROL PANELS, WATER COOLERS, WALL
HUNG SINKS, URINALS, TOILETS, MIRRORS, SOAP DISPENSERS, PAPER
TOWEL DISPENSERS, NAPKIN DISPOSAL, TOILET PARTITIONS, URINAL
SCREENS, TOILET PAPER DISPENSERS, SIGNAGE, GRAB BARS, FIRE ALARM
PANELS AND MASTER CLOCKS, ETC.
J. INTERIOR CONTROL JOINTS ON GYPSUM BOARD SURFACES SHALL BE 24'-0"
ON CENTER MAX AND AS INDICATED WITH-IN. PROVIDE CONTROL JOINT AT
EACH SIDE OF DOOR FRAME, TYPICAL.
K. ALL CONTROL JOINTS (CJ) SHALL BE CAULKED AT EXTERIOR WALL
LOCATIONS AND RAKED BACK 3/4 INCH AT ALL INTERIOR JOINTS UNLESS
OTHERWISE NOTED.
L. PATCH EXISTING WALLS, FLOORS, AND CEILING SURFACES DEMOLISHED,
CUT, CORED, OR ALTERED IN ANY WAY TO ACCOMMODATE NEW
CONSTRUCTION OR TO RECEIVE NEW FINISHES. PREP ALL EXISTING
FLOORS TO RECEIVE NEW FINISHES PER ROOM FINISH SCHEDULE.
M. SEE SHEET A301 FOR DOOR AND ROOM FINISH SCHEDULES.
N. SEE SHEET A101 FOR PARTITION TYPES AND NOTES.
O. ANY EXCAVATION BY THE CONTRACTOR SHALL BE COORDINATED WITH THE
BADLANDS NATIONAL PARK SERVICE AND COR FOR PALEONTOLOGY
SCREENING.
TRUE
NORTH
PLAN
NORTH
NORTH
NORTH
ARROW
NAME
ELEVATION
LEVEL
MATCHLINE
AREA A
AREA B
TITLE
MARKER
VIEW NAME
SCALE: 1/8" = 1'-0"
EXISTING
COLUMN
NEW
COLUMN
X
X
X
XX-XX
SIM
X
XX-XX
XXXX
DX
X
SECTION/
DETAIL
PLAN
DETAIL
REFERENCE
NOTE
REFERENCE
DEMOLITION
NOTE
EQUIPMENT
NUMBER
ROOM NAME
150 SF
ROOM
NUMBER
LETTER INDICATES
NEW COLUMN LINE
LETTER INDICATES
EXISTING COLUMN LINE
SECTION/DETAIL
NUMBER
SHEET NUMBER
INDICATES DIRECTION
OF VIEW
DETAIL NUMBER
SHEET NUMBER
REFERENCE
DESIGNATION
DEMOLITION
DESIGNATION
EQUIPMENT
NUMBER
ROOM NAME
DESIGNATION
ROOM NUMBER
DESIGNATION
ROOM AREA
DESIGNATION
ROOM /
FRAMING
ELEVATION
EXTERIOR
ELEVATION
XX-XX
XX-XX
ELEVATION LETTER
DIRECTION OF VIEW
SHEET NUMBER
ELEVATION LETTER
DIRECTION OF VIEW
SHEET NUMBER
DOOR
NUMBER
DOOR NUMBER10
WINDOW
DESIGNATION
WINDOW DESIGNATION000
TA-X
TOILET
ACCESSORY
TOILET ACCESSORY
NUMBER
WALL
TYPE
LETTER
INDICATES
PARTITION OR
WALL TYPE
X
DETAIL NUMBER
LEVEL CALLOUT
DESIGNATION
ELEVATION
DESIGNATION
GRAPHIC AREA FOR
DRAWING
TITLE
SCALE OF THE
DRAWING
ABBREVIATIONSREFERENCE LEGEND
ARCHITECTURAL SHEET LIST
GENERAL NOTESGENERAL DEMO NOTES
S SOUTH
SA SUPPLY AIR
SAN SANITARY
SB SECURITY BARS
SB SPLASH BLOCK
SCH SCHEDULE
SCHED SCHEDULE
SCR SCREW
SCT STRUCTURAL CLAY TILE
SCUT SCUTTLE
SCW SOFT COLD WATER
SD STORM DRAIN
SD SUBDRAIN
SDI STEEL DECK INSTITUTE
SECT SECTION
SECY SECRETARY
SEQ SEQUENCE
SF SQUARE FOOT (FEET)
SFU STRUCTURAL FACING
UNIT
SHLD SHOULDER
SHT SHEET
SHTG SHEATHING
SHW SOFT HOT WATER
SIM SIMILAR
SJI STEEL JOIST INSTITUTE
SL SNOW LOAD
SLBB SHORT LEG BACK TO
BACK
SM SPRINKLER MAIN
SOV SHUT OFF VALVE
SPA SPACE(ING)
SPEC SPECIFICATIONS
SPF SOUNDPROOF
SPH SPACE HEATER
SPKR SPEAKER
SPL SPECIAL
SQ SQUARE
SS SANITARY SEWER
SS STAINLESS STEEL
SSMR STANDING SEAM METAL
ROOFING
STA STATION
STAIR STAIRWAY
STC SOUND TRANSMISSION
COEFFICIENT
STD STANDARD
STGR STRINGER
STIFF STIFFENER
STIRR STIRRUPS
STL STEEL
STN STONE
STOR STORAGE
STR STRUCTURAL
SUB FL SUB FLOOR
SUCT SUCTION
SUSP SUSPENDED
SVF SHEET VINYL FLOORING
SW SWITCH
SWBD SWITCH BOARD
SYM SYMMETRICAL
T TREAD
T or TLT TOILET
TAN TANGENT
TBD TACK BOARD
TE TOP ELEVATION
TEL TELEPHONE
TEMP TEMPERATURE
TER TERRAZZO
TERM TERMINAL
TGL TOGGLE
TH THRESHOLD
THK THICK
THRD THREAD
TO TOP OF
TOB TOP OF BEAM
TOC TOP OF CONCRETE
TOF TOP OF FOOTING
TOJ TOP OF JOIST
TOPO TOPOGRAPHIC
TOS TOP OF STEEL
TOW TOP OF WALL
TRANS TRANSVERSE
TSTAT THERMOSTAT
TV TELEVISION
TW TEMPERED WATER
TWR TEMPERED WATER
RETURN
TYP TYPICAL
UC UNIT COOLER
UG UNDERGROUND
UH UNIT HEATER
UL UNDERWRITERS
LABORATORIES
UNEX UNEXCAVATED
UNFIN UNFINISHED
UNO UNLESS NOTED
OTHERWISE
UPS UNINTERRUPTIBLE
POWER SYSTEM
UR URINAL
UT UTILITY
UV UNIT VENTILATOR
V VOLT
VAC VACUUM
VAV VARIABLE AIR VOLUME
VCP VITRIFIED CLAY PIPE
VCT VINYL COMPOSITION TILE
VD VAULT DOOR
VEL VELOCITY
VENT VENTILATOR(ION)
VERT VERTICAL
VEST VESTIBULE
VFD VARIABLE FREQUENCY
DRIVE
VOL VOLUME
VPC VERTICAL POINT OF
CURVATURE
VPI VERTICAL POINT OF
INTERSECTION
VPT VERTICAL POINT OF
TANGENCY
VS VENT STACK
VT VINYL-TILE
VTR VENT THRU ROOF
VWC VINYL WALL COVERING
W WEST
W WIDE (WIDTH)
W WIRE
W/ WITH
W/O WITHOUT
WB WET BULB
WC WATER CLOSET
WC WATER COLUMN
WD WASTE DRAIN
WD WOOD
WD BLKG WOOD BLOCKING
WD DR WOOD DOOR
WDW WINDOW
WF WIDE FLANGE
WG WIRE GLASS
WH WALL HYDRANT
WHT WHITE
WI WROUGHT IRON
WKSH WORK SHOP
WL WIND LOAD
WNSCT WAINSCOT
WP WEATHER PROOF
WP WORK POINT
WPF WATER PROOF
WPFG WATER PROOFING
WRB WARDROBE
WS WASTE STACK
WT WEIGHT
WWF WELDED WIRE FABRIC
WWM WOVEN WIRE MESH
XFMR TRANSFORMER
YD YARD or YARD DRAIN
LBS POUNDS
LD LOAD
LDG LOADING
LE LEFT END
LG LENGTH (LONG)
LIN LINEAR
LIS LAWN IRRIGATION
SYSTEM
LL LIVE LOAD
LLBB LONG LEG BACK TO BACK
LLH LONG LEG HORIZONTAL
LLV LONG LEG VERTICAL
LNTL LINTEL
LP LOW POINT
LPG LIQUIFIED PETROLEUM
GAS
LPS LOW PRESSURE STEAM
LR LIVING ROOM
LS LAWN SPRINKLER
LT LIGHT
LT WT LIGHT WEIGHT
LTG LIGHTING
LVT LUXURY VINYL TILE
M MIDDLE
M THOUSAND
M & B MATCHED AND BEADED
MA MAKE-UP AIR
MACH MACHINE
MAS MASONRY
MAT or
MATL
MATERIAL
MAX MAXIMUM
MB MACHINE BOLT
MBH 1000 BTUH
MC MEDICINE CABINET
MC MISCELLANEOUS
CHANNELS
MECH MECHANICAL
MER MECHANICAL EQUIPMENT
ROOM
MET METAL
MFG MANUFACTURING
MFR MANUFACTURER
MH MANHOLE
MIN MINIMUM
MISC MISCELLANEOUS
ML METAL LATH
MLDG MOULDING
MO MASONRY OPENING
MONO MONOLITHIC
MT METAL THRESHOLD
MTD MOUNTED
N NORTH
NC NORMALLY CLOSED
NEC NATIONAL ELECTRICAL
CODE
NEMA NATIONAL ELECTRICAL
MANUFACTURERS
ASSOCIATION
NFPA NATIONAL FIRE
PROTECTION
ASSOCIATION
NIC NOT IN CONTRACT
NO NORMALLY OPEN
NO NUMBER
NR NOT REQUIRED
NS NEAR SIDE
NTS NOT TO SCALE
OA OUTSIDE AIR
OB WG OBSCURE WIRE GLASS
OBGL OBSCURE GLASS
OBSC OBSCURE
OC ON CENTER(S)
OCEW ON CENTER EACH WAY
OD OUTSIDE DIAMETER
OFF OFFICE
OH OVERHEAD
OPNG OPENING
OPP OPPOSITE
OPS OPERATIONS
OS & Y OUTSIDE SCREW & YOKE
OSF OUTSIDE FACE
OV OVERFLOW VALVE
OX OXYGEN
OZ OUNCE
P PAINT
PA PUBLIC ADDRESS
PBS PUSH BUTTON STATION
PC PIECE
PC POINT OF CURVATURE
PC PRECAST
PCC PORTLAND CEMENT
CONCRETE
PCT PORCELAIN CERAMIC TILE
PD PRESSURE DROP
PE POLYETHYLENE
PEN PENETRATION
PERF PERFORATED
PH PHASE
PHAR PHARMACY
PI POINT OF INTERSECTION
PIV POST INDICATING VALVE
PL or P PLATE
PLAM PLASTIC LAMINATE
PLAS PLASTER
PLATF PLATFORM
PLBG PLUMBING
PLG PILING
PLWD PLYWOOD
PNL PANEL
POL POLISH(ED)
PORC PORCELAIN
PPM PARTS PER MILLION
PR PAIR
PREFAB PREFABRICATED
PREFIN PREFINISHED
PRESS PRESSURE
PROJ PROJECT
PRV PRESSURE REGULATING
VALVE
PS PRESSED STEEL
PSFT POUNDS PER SQUARE
FOOT
PSI POUNDS PER SQUARE
INCH
PT POINT
PT POINT OF TANGENCY
PTD PAINTED
PTN PARTITION
PVC POLYVINYL-CHLORIDE
PVMT PAVEMENT
PW PASS WINDOW
1/4 RD QUARTER ROUND
QT QUARRY TILE
QT QUART
QTRS QUARTERS
QTY QUANTITY
QTZ QUARTZ
R REGISTER
R RISER
RA RETURN AIR
RAD OR
R
RADIUS
RB RESILIENT BASE
RC REMOTE CONTROL
RCP REINFORCED CONCRETE
PIPE
RD ROOF DRAIN
RE RIGHT END
REC RECEIVER
RECP RECEPTACLE
RECR RECREATION
RECT RECTIFIER
REF REFERENCE
REFR REFRIGERANT
REFR REFRIGERATOR
REG REGISTER
REINF REINFORCEMENT
REM REMOVE(ABLE)
REQD REQUIRED
RESIL RESILIENT
REV REVISIONS
RFG ROOFING
RH RELATIVE HUMIDITY
RL REFRIGERANT LIQUID
RM ROOM
RND ROUND
RO ROUGH OPENING
RPM REVOLUTIONS PER
MINUTE
RT RUBBER TILE
RTU ROOF TOP UNIT
RUB RUBBER
DIAG DIAGONAL
DIM DIMENSION
DIP DUCTILE IRON PIPE
DISC DISCONNECT
DIST DISTRIBUTION
DL DEAD LOAD
DMPR DAMPER
DN DOWN
DP DAMP PROOFING
DPT DEW POINT
DR DOOR
DRN DRAIN
DS DOWN SPOUT
DV DENTAL VACUUM
DWG DRAWING
DWLS DOWELS
DX DIRECT EXPANSION
E EAST
EA EACH
EA EXHAUST AIR
EDH ELECTRIC DUCT HEATER
EER ENERGY EFFICIENCY
RATIO
EJ EXPANSION JOINT
EL OR
ELEV
ELEVATION - GRADE OR
BUILDING
ELEC ELECTRIC OR ELECTRICAL
ELEV ELEVATOR
ENCL ENCLOSURE
ENT ENTERING
ENT ENTRANCE
EQ EQUAL
EQUIP EQUIPMENT
ES EACH SIDE
EST ESTIMATE
EVAP EVAPORATOR
EW EACH WAY
EWC ELECTRIC WATER
COOLER
EXC EXCAVATE
EXD EXIT DEVICE
EXH EXHAUST
EXIST EXISTING
EXP EXPOSED
EXPL EXPLOSION
EXPN EXPANSION
EXT EXTERIOR
F FAHRENHEIT
F FIRE
FA FRESH AIR
FCG FACING
FD FLOOR DRAIN
FDN FOUNDATION
FE FIRE EXTINGUISHER
FEB FIRE EXTINGUISHER
BRACKET
FEC FIRE EXTINGUISHER
CABINET
FH FIRE HYDRANT
FHC FIRE HOSE CABINET
FIG FIGURE
FIN FINISH
FIX FIXTURE
FL or FLR FLOOR
FLASH FLASHING
FLEX FLEXIBLE
FLG FLANGE
FLG FLOORING
FLUOR FLUORESCENT
FP FIRE PROTECTION
FPM FEET PER MINUTE
FPRF FIRE PROOF
FR FRAME
FRG FURRING
FS FAR SIDE
FS FLOOR SINK
FS FULL SIZE
FT FEET (FOOT)
FTG FOOTING
FV FIELD VERIFY
FWC FABRIC WALL COVERING
G GRILLE
G NATURAL GAS
GA GAGE OR GAUGE
GAL GALLON
GALV GALVANIZED
GEN GENERAL
GFE GOVERNMENT FURNISHED
EQUIPMENT
GFE/CI GOVERNMENT FURNISHED
EQUIPMENT/CONTRACTOR
INSTALLED
GFI GROUND FAULT
INTERRUPTER
GI GALVANIZED IRON
GL GLASS
GND GROUND
GOVT GOVERNMENT
GPH GALLONS PER HOUR
GPM GALLONS PER MINUTE
GR GRADE
GRS GALVANIZED RIGID STEEL
CONDUIT
GRTG GRATING
GSU GLAZED STRUCTURAL
UNITS
GWB GYPSUM WALLBOARD
GWT GLAZED WALL TILE
GYP GYPSUM
H or HT HEIGHT (HIGH)
HB HOSE BIBB
HBD HARDBOARD
HC HANDICAPPED
HD HEAD
HDPE HIGH DENSITY
POLYETHYLENE
HDR HEADER
HDW HARDWARE
HIP HIGH PRESSURE
HM HOLLOW METAL
HORIZ HORIZONTAL(LY)
HP HORSE POWER
HPS HIGH PRESURE STEAM
HPT HIGH POINT
HR HOUR
HS HIGH STRENGTH
HSGYP HIGH STRENGTH GYPSUM
PLASTER
HTG HEATING
HTR HEATER
HW HEAD WALL
HW HOT WATER
HWH HOT WATER HEATER
HWR HOT WATER RETURN
(HEATING)
HWS HOT WATER SUPPLY
(HEATING)
HYD HYDRAULIC
I or FE IRON
IC INTERCOM
ID INSIDE DIAMETER
IE INVERT ELEVATION
IES ILLUMINATING
ENGINEERING SOCIETY
IN INCH
INSUL INSULATION
INT INTERIOR
INV INVERT OR INVERTER
IP IRON PIPE
ISF INSIDE FACE
JB JUNCTION BOX
JBOX JUNCTION BOX
JC JANITOR CLOSET
JCT JUNCTION
JST JOIST
JT JOINT
K KEY
KCP KEENE'S CEMENT
PLASTER
KIP or K KILOPOUND (1000 LBS)
KIT KITCHEN
KL KEY LOCK
KP KICK PLATE
KV KILOVOLTS
KVA KILOVOLT AMPERES
KW KILOWATT
LAB LABORATORY
LAU LAUNDRY
LAV LAVATORY
LBR LUMBER
A COMPRESSED AIR
A/C AIR CONDITIONING
AB ANCHOR BOLT
ABS ACRYLONITRILE BUTAD
STYRENE
AC ALTERNATING CURRENT
ACI AMERICAN CONCRETE
INSTITUTE
ACSR ALUMINUM CONDUCTOR
STEEL REINFORCED
ACST ACOUSTIC
AD ACCESS DOOR
AD AREA DRAIN
ADMIN ADMIN ADMINISTRATION
(IVE)
AFF ABOVE FINISH FLOOR
AFFF AQUEOUS FILM FORMING
FOAM
AGG AGGREGATE
AHU AIR HANDLING UNIT
AI AREA INLET
AIC AMPS INTERRUPTING
CAPACITY (SYM RMS)
AISC AMERICAN INSTITUTE OF
STEEL CONSTRUCTION
AL ACTIVE LEAF
AL ALUMINUM
ALT ALTERNATE
AMP AMPERE
ANSI AMERICAN NATIONAL
STANDARDS INSTITUTE
AP ACCESS PANEL
APD AIR PRESSURE DROP
APPD APPROVED
APPROX APPROXIMATE
ARCH ARCHITECTURAL OR
ARCHITECT
ARI AMERICAN
REFRIGERATION
INSTITUTE
ASB ASBESTOS
ASPH ASPHALT
APC ACOUSTICAL PANEL
CEILING
AUTO AUTOMATIC
AV ACID VENT
AVG AVERAGE
AW ACID WASTE
AWC ACOUSTICAL WALL
COVERING
AWG AMERICAN WIRE GAUGE
L ANGLE
BATT BATT INSULATION
BB BULLETIN BOARD
BBO BOILER BLOW OFF
BC BOOKCASE
BD BOARD
BDY BOUNDARY
BEJ BRICK EXPANSION JOINT
BIT BITUMINOUS
BKR BREAKER
BL BUILDING LINE
BLDG BUILDING
BLK BLOCK
BLKG BLOCKING
BM BEAM
BM BENCH MARK
BO BOTTOM OF
BOT BOTTOM
BRCG BRACING
BRDG BRIDGING
BRG BEARING
BRK BRICK
BRKT BRACKET
BS BOTH SIDES
BTU BRITISH THERMAL UNIT
BTUH BTU PER HOUR
BUR BUILT-UP ROOFING
BW BOTH WAYS
C CENTER
C OR
CND
CONDUIT (ELECTRICAL
SHEETS)
C TO C CENTER TO CENTER
CAP CAPACITY
CB CATCH BASIN (OR CIRCUIT
BREAKER)
CC CENTER TO CENTER
CCT CIRCUIT
CD CONDENSATE DRAIN
CE COVER ELEVATION
CEM CEMENT
CF CUBIC FEET
CFH CUBIC FEET PER HOUR
CFM CUBIC FEET PER MINUTE
CHIM CHIMNEY
CI CAST IRON
CI CURB INLET
CIP CAST IN PLACE
CIR CIRCULAR
CJ CONTROL JOINT
CKT CIRCUIT
CL CENTER LINE
CL WG CLEAR WIRE GLASS
CLG CEILING
CLKG CAULKING
CMP CORRUGATED METAL PIPE
CMU CONCRETE MASONRY
UNIT
CNTR COUNTER
CO CLEAN OUT
CO2 CARBON DIOXIDE
COL COLUMN
COM COMMON
COMB COMBINATION
COMB COMBUSTION
COMP COMPRESSIBLE
COMPR COMPRESSOR
CONC CONCRETE
CONF CONFERENCE
CONN CONNECTION
CONSTR CONSTRUCTION
CONSTR
JT
CONSTRUCTION JOINT
CONT CONTINUOUS
(CONTINUATION)
CONTR CONTRACTOR
COR CORNER
CORR COVERED
COV CORRIDOR
CPL CEMENT PLASTER
CPS CYCLES PER SECOND
(HERTZ)
CPT CARPET
CR CONDENSER WATER
RETURN
CRES CORROSIVE RESISTANT
STEEL
CRG CARRIAGE
CRSE COURSE
CS CONDENSER WATER
SUPPLY
CS COUNTER SINK
CSMT CASEMENT
CT CERAMIC TILE
CT CURRENT TRANSFORMER
CTL CARPET TILE
CU CONDENSING UNIT
CU YD CUBIC YARDS
CUH CABINET UNIT HEATER
CV CEILING VENT
CW COLD WATER
CWR CHILLED WATER RETURN
CWS CHILLED WATER SUPPLY
CYL CYLINDER
D DEPTH (DEEP)
D DIFFUSER
d PENNY (as in nail - 10d)
D&M DRESSED AND MATCHED
DA DOUBLE ACTING
DB DRY BULB
dB DECIBEL
DBL DOUBLE
DC DIRECT CURRENT
DCJ DOWELED CONTROL
JOINT
DCJT DUMMY CONTROL JOINT
DCL DOOR CLOSER
DCW DOMESTIC COLD WATER
DEG DEGREE
DEMO DEMOLITION
DEPR DEPRESSION
DEPT DEPARTMENT
DET DETAIL
DF DRINKING FOUNTAIN
DH DOUBLE HUNG
DHW DOMESTIC HOT WATER
DI DEIONIZED WATER
DIA DIAMETER
CLO CLOSET
FR FIRE RATED
U/C UNDER CABINET
SYMBOL LEGEND
PLAN VIEW
SECTION / ELEVATION VIEW
SHEAR WALL
MASONRY-CMU
CONCRETE
GRAVEL
EARTH / COMPACTED
EARTH /
NONCOMPACTED
RIGID INSULATION
JOINT FILLER
STEEL
GYPSUM
MASONRY-VENEER
STUD WALL
FLEXIBLE INSULATION
GROUT
PLYWOOD
WOOD (FINISH)
MASONRY-CMU FACE
MASONRY-CMU
MASONRY-VENEER
(402) 493-4800 www.schemmer.com
REVISED TITLE OF SHEET DRAWING NO.
SHEET
PMIS / PKG. NO.
OF
SUB SHEET NO.
ARCH/ENG PROJ #
DESIGNED
DRAWN
CHECKED
PREPARED
DATE
227763 / 80111
177740
C U s e rs \b b e n tz in g e r\ D o c u m e n ts \0
-A
R C
H
R b ill
H
P G
.r v t
PJB
PJB
PJB
01/28/2022
07310.022
A 000
ARCHITECTURAL INFO SHEET
07310022- 2- A 000 ARCHITECTURAL INFO SHEET
REHAB CEDAR PASS COTTAGE
CEDAR PASS LODGE
20681 SD-240, INTERIOR, SD 57750
REF. DEMO NOTES ( )
PROJECT ARCHITECTURAL REFERENCED DEMOLITION NOTES
XDX
PROJECT ARCHITECTURAL REFERENCED NOTES
REF. NOTES ( )
1.02 REMOVE FOUNDATION WALL AND FOOTING.
1.04 REMOVE CONCRETE FLOOR SLAB.
1.06 REMOVE CHIMNEY
1.08 REMOVE WOOD STUD WALL.
1.09 REMOVE MASONRY WALL.
1.10 REMOVE AND REINSTALL PINE WALL PANELING, WALL BASE AND
TRIM. TO BE REINSTALLED IN BEDROOM 2-#107.
1.12 REMOVE GYPSUM WALL BOARD.
1.13 REMOVE FLOOR STRUCTURE, SHEATHING, & FLOOR COVERING
FOR ENTIRE LEVEL.
1.15 REMOVE A PORTION OF WALL FOR NEW OPENING.
1.17 REMOVE DOOR AND FRAME.
1.20 REMOVE AND REINSTALL DOOR, TRIM, AND FRAME. NEW
LOCATION DOOR 108-B
1.25 REMOVE ROOF TRUSSES, ROOF SHEATHING, INSULATION, &
METAL ROOFING
1.26 REMOVE WINDOW.
1.28 REMOVE SMOKE DETECTORS
1.31 REMOVE FURNACE AND DUCTWORK
1.32 REMOVE GYPSUM BOARD CEILING AND FRAMING.
1.35 REMOVE LIGHTING. REFER TO ELECTRICAL.
1.41 REMOVE STAIRS
1.43 REMOVE WATER HEATER AND PIPING. REFER TO MECHANICAL.
1.44 REMOVE PLUMBING FIXTURE. REFER TO MECHANICAL.
1.46 REMOVE BASE CABINET AND COUNTERTOP.
1.47 REMOVE UPPER WALL CABINET.
1.66 REMOVE SHOWER ROD AND CURTAIN.
1.68 REMOVE ALL TOILET ACCESSORIES.
1.99 POSSIBLE PANEL LOCATIONS FOR WALL REMOVAL AND
REINSTALLATION NOTED BY HEAVY LINES.
3.05 EXTERIOR WALL TO BE FILLED WITH NEW SPRAY-ON INSULATION
R-20 MIN, TYPICAL
3.09 EIFS FAUX CHIMNEY BEGINS @ TRUSS BEARING
3.13 24" X 24" LIFT OUT ACCESS PANEL TO CRAWL SPACE. MFR TO
PROVIDE KEY LOCKING SECURITY DEVICE TO PREVENT
UNAUTHORIZED ACCESS. BELOW ACCESS PANEL, IN CRAWL
SPACE, PROVIDE ACCESS LADDER. MOUNT LADDER TO 2X4 WALL
FROM FLOOR JOISTS TO FLOOR OF CRAWL SPACE. ALL WOOD IN
CONTACT WITH CONCRETE FLOOR SHALL BE TREATED.
3.17 NEW 5/8" GWB ON EXTERIOR WALLS, TYP.
3.18 NEW 3/8" PLYWOOD ON EXTERIOR WALLS WITH REINSTALLED PINE
PANELING, WALL BASE, AND TRIM. PINE PANELING TO BE
FURBISHED TO MATCH ORIGINAL FOR CONSISTENT COLOR AND
FINISH.
4.05 30" X 60" ROLL-IN FIBERGLASS SHOWER STALL
4.07 TANK STYLE WATER CLOSET. SEE PLUMBING
4.19 RANGE HOOD, PROVIDE REMOTE ACTIVATION. REFER TO MECH.
FURNISHED BY CONTRACTOR,. INSTALLED BY CONTRACTOR.
4.20 SINK. REFER TO PLUMBING
4.25 WOOD BASE CABINET.
4.28 WOOD WALL CABINET.
4.29 OPEN SHELF WALL CABINET. EXPOSED INTERIOR SURFACE SHALL
BE PLASTIC LAMINATE.
4.35 FINISHED END PANEL - WOOD CABINET
4.37 PLASTIC LAMINATE COUNTERTOP WITH INTEGRAL BACKSPLASH.
SCRIBE TO WALL.
4.38 SOLID SURFACE COUNTERTOP WITH INTEGRAL BACKSPLASH.
SCRIBE TO WALL.
4.43 SOLID SURFACE VANITY COUNTERTOP WITH UNDER-MOUNT SINK.
4.44 SOLID SURFACE VANITY COUNTERTOP WITH INTEGRAL SINK. OPEN
BELOW FOR ABAAS ACCESS
4.50 COUNTERTOP SUPPORT BRACKET.
4.65 REFRIGERATOR FURNISHED BY CONTRACTOR, INSTALLED BY
CONTRACTOR.
4.66 RANGE FURNISHED BY CONTRACTOR, INSTALLED BY CONTRACTOR.
4.68 DISHWASHER FURNISHED BY CONTRACTOR, INSTALLED BY
CONTRACTOR.
4.69 MICROWAVE FURNISHED BY CONTRACTOR, INSTALLED BY
CONTRACTOR.
4.73 REINSTALL EXISTING WOOD BASE. IF UNABLE TO RE-USE, INSTALL
MATCHING MATERIAL IN KIND
4.74 REINSTALL EXISTING WOOD CROWN MOLDING. IF UNABLE TO
RE-USE, INSTALL MATCHING MATERIAL IN KIND
4.80 CLOSET ROD & SHELF
5.03 5/8" GYPSUM BOARD CEILING ATTACHED TO BTTM OF TRUSS
5.21 24" SQ. ATTIC ACCESS PANEL. MFR TO PROVE KEY LOCKING
SECURITY DEVICE.
5.31 EXHAUST FAN, REFER TO MECH
5.34 SURFACE MOUNTED LIGHT FIXTURE. REFER TO ELECTRICAL.
6.06 SYNTHETIC COMPOSITE CEDAR SHAKE ROOFING
6.19 PREFINISHED METAL GUTTER
6.20 PREFINISHED 2" X 3" METAL DOWNSPOUT WITH EXTENSION.
7.06 EXTERIOR FINISH INSULATION SYSTEM (EFIS-1)
7.07 FAUX CHIMNEY - 2X6 FRAMING WITH EIFS FINISH (EFIS-1)
7.14 FIBER-CEMENT TEXTURED 5/4 TRIM BOARD. 8" WIDTH: PAINTED
7.33 MECHANICAL EXHAUST VENT. REFER TO MECHANICAL.
7.34 ELECTRICAL EQUIP. REFER TO ELECTRICAL.
7.36 MECHANICAL SUPPLY VENT. REFER TO MECHANICAL.
7.40 12"X18" THRU-WALL LOUVERED VENT WITH INSECT SCREEN.
CENTER ON GABLE.
8.02 CONCRETE FOUNDATION WALL. REFER TO STRUCTURAL.
8.04 SPRAY-ON INSULATION WITH DEPTH NECESSARY TO ACHIEVE AN
R-VALUE OF 30
8.06 VAPOR BARRIER - VAPOR RETARDER FOR CRAWL SPACES
8.07 WOOD FLOOR JOIST. REFER TO STRUCTURAL.
8.08 WOOD ROOF TRUSS. REFER TO STRUCTURAL.
8.09 CRAWL SPACE DRAINAGE SYSTEM, REFER TO STRUCTURAL.
8.10 WATERPROOFING SYSTEM: SHEET WATERPROOFING MEMBRANE,
2" RIGID INSULATION PROTECTION BOARD, 1/4" DRAINAGE PANEL.
8.12 WD BEAM. REFER TO STRUCTURAL.
8.13 COLUMN. REFER TO STRUCTURAL.
8.14 ADA KNEE & TOE CLEARANCES
UP
WH
1.26 1.26
1.26
1.26
1.26 1.26 1.26
1.26
1.26
1.26
1.26
1.26
1.26
1.26
1.17
1.171.17
1.17
1.17
1.17
1.17
1.17
1.17
1.171.17
1.12
1.12
1.12
1.12
1.12
1.12
1.12
1.12
1.12
1.12
1.12
1.12
1.12
1.12
1.121.12
1.12
1.20
1.12
1.10
1.10 1.10
1.10 1.10
1.10
1.08
1.08
1.08
1.08
1.06
1.44
1.44
1.44
1.44
1.44
1.66
1.68
1.15
1.15
1.15
1.15
1.15
1.15
1.131.13
1.131.13
1.131.13
1.131.13
1.46
1.46
1.46
1.46
1.47
1.47
1.47 1.47
1.47
1.08
1.15
1.41
1.02
1.02
1.02
1.02
1.02
1.02
1.02
1.02
1.02
1.02
1.41
1.041.04
1.09
1.09
1.06
1.31
1.43
1044 North 115th Street | Suite 300
Omaha, NE 68154
(402) 493-4800 www.schemmer.com
REVISED TITLE OF SHEET DRAWING NO.
SHEET
PMIS / PKG. NO.
OF
SUB SHEET NO.
ARCH/ENG PROJ #
DESIGNED
DRAWN
CHECKED
PREPARED
DATE
227763 / 80111
177740
C U s e rs \b b e n tz in g e r\ D o c u m e n ts \0
-A
R C
H
R b ill
H
P G
.r v t
RJM
WEB
PJB
01/28/2022
07310.022
A001
DEMOLITION FLOOR PLANS
07310022- 2- A001 DEMOLITION FLOOR PLANS
REHAB CEDAR PASS COTTAGE
CEDAR PASS LODGE
20681 SD-240, INTERIOR, SD 57750
REF. DEMO NOTES ( ):DX
1.02 REMOVE FOUNDATION WALL AND FOOTING.
1.04 REMOVE CONCRETE FLOOR SLAB.
1.06 REMOVE CHIMNEY
1.08 REMOVE WOOD STUD WALL.
1.09 REMOVE MASONRY WALL.
1.10 REMOVE AND REINSTALL PINE WALL PANELING, WALL BASE AND TRIM. TO
BE REINSTALLED IN BEDROOM 2-#107.
1.12 REMOVE GYPSUM WALL BOARD.
1.13 REMOVE FLOOR STRUCTURE, SHEATHING, & FLOOR COVERING FOR
ENTIRE LEVEL.
1.15 REMOVE A PORTION OF WALL FOR NEW OPENING.
1.17 REMOVE DOOR AND FRAME.
1.20 REMOVE AND REINSTALL DOOR, TRIM, AND FRAME. NEW LOCATION DOOR
108-B
1.26 REMOVE WINDOW.
1.31 REMOVE FURNACE AND DUCTWORK
1.41 REMOVE STAIRS
1.43 REMOVE WATER HEATER AND PIPING. REFER TO MECHANICAL.
1.44 REMOVE PLUMBING FIXTURE. REFER TO MECHANICAL.
1.46 REMOVE BASE CABINET AND COUNTERTOP.
1.47 REMOVE UPPER WALL CABINET.
1.66 REMOVE SHOWER ROD AND CURTAIN.
1.68 REMOVE ALL TOILET ACCESSORIES.
SCALE: 1/4" = 1'-0"
FIRST FLOOR - DEMOLITION
SCALE: 1/4" = 1'-0"
SUB GRADE - DEMOLITION
NORTH
DATE INITIAL
GENERAL NOTES
1. ALL WALLS TO BE REMOVED, PROTECTED, AND STORED ON
SITE, AND REINSTALLED ON NEW FOUNDATION.
2. CONTRACTOR HAS OPTION TO PANELIZE THE WALL
SECTIONS FOR REMOVAL AND REINSTALLATION.
3. NOTIFY CONTRACTING OFFICER OF ANY STUDS OR SILL
PLATES WHICH HAVE DETERIORATED AND ARE DEEMED
UNACCEPTABLE FOR REUSE; REFER TO CONTRACT PRICE
SCHEDULE OPTIONS A AND B IN ORDER TO SUBMIT AND
ACQUIRE CONTRACTING OFFICER'S APPROVAL AND
ACCEPTANCE OF MODIFICATION.
4. SALVAGED WALLS FOR REINSTALLATION ARE TO CONSIST
OF WOOD FRAMING ONLY, AND SHALL BE CLEAN OF
SHEATHING, INTERIOR AND EXTERIOR FINISHES, NAILS,
SCREWS, AND OTHER ITEMS WHICH WOULD INTERFERE WITH
THE INSTALLATION OF NEW SHEATHING, INTERIOR AND
EXTERIOR FINISHES, AND COMPONENTS . SALVAGED WALLS
TO BE LEVEL AND TRUE.
S
1.25
1.25
1.25
1.25
1.25
1.06
1.32
1.32
1.32
1.32
1.32
1.32
1.32 1.32
1.32
1.32
1.35
1.35
1.35 1.35
1.35 1.35
1.35
1.35
1.28
1.28
1.35
1.06
1044 North 115th Street | Suite 300
Omaha, NE 68154
(402) 493-4800 www.schemmer.com
REVISED TITLE OF SHEET DRAWING NO.
SHEET
PMIS / PKG. NO.
OF
SUB SHEET NO.
ARCH/ENG PROJ #
DESIGNED
DRAWN
CHECKED
PREPARED
DATE
227763 / 80111
177740
C U s e rs \b b e n tz in g e r\ D o c u m e n ts \0
-A
R C
H
R b ill
H
P G
.r v t
RJM
Author
WEB
01/28/2022
07310.022
A002
DEMOLITION REFLECTED
CEILING PLAN & ROOF
07310022- 2- A002 DEMOLITION REFLECTED CEILING PLAN & ROOF
REHAB CEDAR PASS COTTAGE
CEDAR PASS LODGE
20681 SD-240, INTERIOR, SD 57750
SCALE: 1/4" = 1'-0"
ROOF PLAN - DEMOLITION
1.06 REMOVE CHIMNEY
1.25 REMOVE ROOF TRUSSES, ROOF SHEATHING, INSULATION, & METAL
ROOFING
1.28 REMOVE SMOKE DETECTORS
1.32 REMOVE GYPSUM BOARD CEILING AND FRAMING.
1.35 REMOVE LIGHTING. REFER TO ELECTRICAL.
REF. DEMO NOTES ( ):DX
SCALE: 1/4" = 1'-0"
FIRST FLOOR - REFLECTED CEILING DEMOLITION
1.06 REMOVE CHIMNEY
1.25 REMOVE ROOF TRUSSES, ROOF SHEATHING, INSULATION, & METAL
ROOFING
1.28 REMOVE SMOKE DETECTORS
1.32 REMOVE GYPSUM BOARD CEILING AND FRAMING.
1.35 REMOVE LIGHTING. REFER TO ELECTRICAL.
NORTH
DATE INITIAL
GENERAL NOTES
1. ALL WALLS TO BE REMOVED, PROTECTED, AND STORED ON
SITE, AND REINSTALLED ON NEW FOUNDATION.
2. CONTRACTOR HAS OPTION TO PANELIZE THE WALL
SECTIONS FOR REMOVAL AND REINSTALLATION.
3. NOTIFY CONTRACTING OFFICER OF ANY STUDS OR SILL
PLATES WHICH HAVE DETERIORATED AND ARE DEEMED
UNACCEPTABLE FOR REUSE; REFER TO CONTRACT PRICE
SCHEDULE OPTIONS A AND B IN ORDER TO SUBMIT AND
ACQUIRE CONTRACTING OFFICER'S APPROVAL AND
ACCEPTANCE OF MODIFICATION.
4. SALVAGED WALLS FOR REINSTALLATION ARE TO CONSIST
OF WOOD FRAMING ONLY, AND SHALL BE CLEAN OF
SHEATHING, INTERIOR AND EXTERIOR FINISHES, NAILS,
SCREWS, AND OTHER ITEMS WHICH WOULD INTERFERE WITH
THE INSTALLATION OF NEW SHEATHING, INTERIOR AND
UP
1.99
Omaha, NE 68154
(402) 493-4800 www.schemmer.com
REVISED TITLE OF SHEET DRAWING NO.
SHEET
PMIS / PKG. NO.
OF
SUB SHEET NO.
ARCH/ENG PROJ #
DESIGNED
DRAWN
CHECKED
PREPARED
DATE
227763 / 80111
177740
C U s e rs \b b e n tz in g e r\ D o c u m e n ts \0
-A
R C
H
R b ill
H
P G
.r v t
WEB
WEB
PJB
01/28/2022
07310.022
A003
DEMOLITION PANEL PLAN
07310022- 2- A003 DEMOLITION PANEL PLAN
REHAB CEDAR PASS COTTAGE
CEDAR PASS LODGE
20681 SD-240, INTERIOR, SD 57750
SCALE: 1/4" = 1'-0"
FIRST FLOOR - DEMOLITION PANELS PLAN
REF. DEMO NOTES ( ):DX
1.99 POSSIBLE PANEL LOCATIONS FOR WALL REMOVAL AND REINSTALLATION
NOTED BY HEAVY LINES.
1.99 POSSIBLE PANEL LOCATIONS FOR WALL REMOVAL AND REINSTALLATION
NOTED BY HEAVY LINES.
NORTH
DATE INITIAL
GENERAL NOTES
1. ALL WALLS TO BE REMOVED, PROTECTED, AND STORED ON
SITE, AND REINSTALLED ON NEW FOUNDATION.
2. CONTRACTOR HAS OPTION TO PANELIZE THE WALL
SECTIONS FOR REMOVAL AND REINSTALLATION.
3. NOTIFY CONTRACTING OFFICER OF ANY STUDS OR SILL
PLATES WHICH HAVE DETERIORATED AND ARE DEEMED
UNACCEPTABLE FOR REUSE; REFER TO CONTRACT PRICE
SCHEDULE OPTIONS A AND B IN ORDER TO SUBMIT AND
ACQUIRE CONTRACTING OFFICER'S APPROVAL AND
ACCEPTANCE OF MODIFICATION.
4. SALVAGED WALLS FOR REINSTALLATION ARE TO CONSIST
OF WOOD FRAMING ONLY, AND SHALL BE CLEAN OF
SHEATHING, INTERIOR AND EXTERIOR FINISHES, NAILS,
SCREWS, AND OTHER ITEMS WHICH WOULD INTERFERE WITH
THE INSTALLATION OF NEW SHEATHING, INTERIOR AND
(402) 493-4800 www.schemmer.com
REVISED TITLE OF SHEET DRAWING NO.
SHEET
PMIS / PKG. NO.
OF
SUB SHEET NO.
ARCH/ENG PROJ #
DESIGNED
DRAWN
CHECKED
PREPARED
DATE
227763 / 80111
177740
C U s e rs \b b e n tz in g e r\ D o c u m e n ts \0
-A
R C
H
R b ill
H
P G
.r v t
WEB
WEB
PJB
01/28/2022
07310.022
A004
DEMOLITION EXISTING
CONDITIONS EXTERIOR
07310022- 2- A004 DEMOLITION EXISTING CONDITIONS EXTERIOR
REHAB CEDAR PASS COTTAGE
CEDAR PASS LODGE
20681 SD-240, INTERIOR, SD 57750
DATE INITIAL
WEST ELEVATION
SITE REPRESENTATIVE PHOTO GALLERY
1. THE FOLLOWING PHOTOGRAPHS DEPICT EXISTING CONDITIONS OF THE HISTORIC COTTAGE FOR CONTRACTOR REFERENCE ONLY AND DOES NOT FULLY PHOTO DOCUMENT THE ENTIRETY OF THE STRUCTURE OR THE PROJECT AREA. BIDDING CONTRACTORS REMAIN RESPONSIBLE FOR FAMILIARIZATION THEMSELVES WITH THE SITE TO THE EXTENT THEY DETERMINE IN ORDER TO PREPARE THEIR BID. THE AWARDED CONTRACTOR SHALL REMAIN RESPONSIBLE FOR TAKING PRE-CONSTRUCTION
PHOTOGRAPHS REQUIRED IN THE SPECIFICATIONS WITHIN THESE DOCUMENTS.
NORTH ELEVATION EAST ELEVATION SOUTH ELEVATION
DAMAGE TO STUCCO & FOUNDATION DAMAGE TO STUCCO & CONDITION OF WINDOWS DAMAGE TO STUCCO AT FOUNDATION
VIEW OF SOFFIT EXISTING WINDOW & STUCCO STANDING SEAM METAL ROOF & CHIMNEY
CONDITION OF EXTERIOR WALLS, FLOOR & STOOP ELECTRICAL SERVICE
(402) 493-4800 www.schemmer.com
REVISED TITLE OF SHEET DRAWING NO.
SHEET
PMIS / PKG. NO.
OF
SUB SHEET NO.
ARCH/ENG PROJ #
DESIGNED
DRAWN
CHECKED
PREPARED
DATE
227763 / 80111
177740
C U s e rs \b b e n tz in g e r\ D o c u m e n ts \0
-A
R C
H
R b ill
H
P G
.r v t
WEB
WEB
PBJ
01/28/2022
07310.022
A005
DEMOLITION EXISTING
CONDITIONS INTERIOR
07310022- 2- A005 DEMOLITION EXISTING CONDITIONS INTERIOR
REHAB CEDAR PASS COTTAGE
CEDAR PASS LODGE
20681 SD-240, INTERIOR, SD 57750
DATE INITIAL
FRONT DOOR & LIVING ROOM LIVING ROOM W/ VIEW TO HALL LIVING ROOM
VIEW TO HALL CABINETS VIEW OF SOUTH WALL KITCHEN & DOOR BEDROOM 2, NORTH &
EAST WALL
BEDROOM 2, WEST & SOUTH WALLS BASEMENT BASEMENT
BEDROOM 1, WEST & NORTH WALLS BEDROOM 1, SOUTH WALL
BATHROOM NORTH WALL BASEMENT STAIRS
SITE REPRESENTATIVE PHOTO GALLERY
1. THE FOLLOWING PHOTOGRAPHS DEPICT EXISTING CONDITIONS OF THE HISTORIC COTTAGE FOR CONTRACTOR REFERENCE ONLY AND DOES NOT FULLY PHOTO DOCUMENT THE ENTIRETY OF THE STRUCTURE OR THE PROJECT AREA. BIDDING CONTRACTORS REMAIN RESPONSIBLE FOR FAMILIARIZATION THEMSELVES WITH THE SITE TO THE EXTENT THEY DETERMINE IN ORDER TO PREPARE THEIR BID. THE AWARDED CONTRACTOR SHALL REMAIN RESPONSIBLE FOR TAKING PRE-CONSTRUCTION
PHOTOGRAPHS REQUIRED IN THE SPECIFICATIONS WITHIN THESE DOCUMENTS.
THE OWNER WILL REMOVE
ALL DEBRIS PRIOR TO THE
CONTRACTOR'S NOTICE TO
PROCEED, TYP.
THE OWNER WILL REMOVE
ALL DEBRIS PRIOR TO THE
CONTRACTOR'S NOTICE TO
PROCEED, TYP.
THE OWNER WILL REMOVE
ALL DEBRIS PRIOR TO THE
CONTRACTOR'S NOTICE TO
PROCEED, TYP.
PINE PANELING, WALL BASE,AND
TRIM TO BE SALVAGED FOR
REINSTALLATION.
THE OWNER WILL REMOVE
ALL DEBRIS PRIOR TO THE
CONTRACTOR'S NOTICE TO
PROCEED, TYP.
THE OWNER WILL REMOVE
ALL DEBRIS PRIOR TO THE
CONTRACTOR'S NOTICE TO
PROCEED, TYP.
-B
REF.
-A
100-C
104-B
-B
100-A
-B
DW
108-A 1
-B
F E
B
LIVING
CLST
BEDROOM 1
CLST
HALL
CLST
BATH
BEDROOM 2
UTIL
108 ENTRY
CLST
KITCHEN
11 5/8"
2'-0 3/4"
/4
3'-4 7/8" 3'-6 7/8"
/4
AA
C
B
C
C C
D
B
A501
A501
A202
A202
W5 W1
W4
2'-10 3/4" 1'-6"
/8
W6
B
4.05
4.44
4.38
A202
A401
4.69
3.13
3.09
W7
W3
W7
W7 W2
W5
W6
4.80
4.80
4.80
3.183.18
3.17
3.173.17
3.17
3.17
3.173.17
3.173.17
3.17
W7
W4
W1
W3
W8
W8
2'-5" 6'-10 7/8" 3'-5 1/2" 5'-5 1/4"
/8
/2
2'-11" 3'-5 3/8"1'-8" 2'-5" 3'-2" 3'-1 1/2"
9" 3'-10"
/2
9" 3'-10"
/2
/4
1'-7 1/4" 3'-3 1/8"
/4
A501
A401
E
E E
3.18
2'-6"
A
A F
4.80
E
4'-0"
E
3.05
3.05
3.05
3.05
3.05
3.05
3.05
3.05
3.05
3.05
A401
6 1/2" / 12"6 1/2" / 12"
6 1/2" / 12"
PREFIN MET GUTTER -
5" K STYLE
SYNTHETIC COMPOSITE CEDAR
SHAKE ROOFING. ICE AND WATER
SHIELD UNDER ENTIRE ROOF
PREFIN MET GUTTER -
5" K STYLE
PREFIN MET GUTTER -
5" K STYLE
FAUX CHIMNEY
LINE OF EXTERIOR
FACE OF WALL BELOW
PREFIN MET GUTTER -
5" K STYLE
SYNTHETIC COMPOSITE CEDAR
SHAKE ROOFING. ICE AND WATER
SHIELD UNDER ENTIRE ROOF
CRICKET
1044 North 115th Street | Suite 300
Omaha, NE 68154
(402) 493-4800 www.schemmer.com
REVISED TITLE OF SHEET DRAWING NO.
SHEET
PMIS / PKG. NO.
OF
SUB SHEET NO.
ARCH/ENG PROJ #
DESIGNED
DRAWN
CHECKED
PREPARED
DATE
227763 / 80111
177740
C U s e rs \b b e n tz in g e r\ D o c u m e n ts \0
-A
R C
H
R b ill
H
P G
.r v t
RJM
WEB
PJB
01/28/2022
07310.022
A101
FLOOR PLAN, ROOF PLAN
07310022- 2- A101 FLOOR PLAN, ROOF PLAN
REHAB CEDAR PASS COTTAGE
CEDAR PASS LODGE
20681 SD-240, INTERIOR, SD 57750
REF. NOTES ( ):X
PARTITION TYPES ( ):X
TYPE WIDTH
A 0' - 4 1/8" 2X4 WD STUD @ 16" OC W/ 5/8" GWB ONE SIDE TO STRUCTURE
ABOVE
B 0' - 4 3/4" 2X4 WD STUD @ 16" OC W/ 5/8" GWB EACH SIDE TO
STRUCTURE ABOVE
C 0' - 4 1/2" 2X4 WD STUD @ 16" OC W/ 5/8" GWB ONE SIDE - 3/8" PLYWOOD
ONE SIDE TO STRUCTURE ABOVE
D 0' - 4 1/4" 2X4 WD STUD @ 16" OC W/ 3/8"" PLWD EACH SIDE TO
STRUCTURE ABOVE
E 0' - 0 3/4" REINSTALLED PINE WALL PANELING
F 0' - 3 7/8" 2X4 WD STUD @ 16" OC W/ 3/8" PLWD ONE SIDE TO
STRUCTURE ABOVE
TOILET ACCESSORIES ( ):TA-X
NUMBER DESCRIPTION
TA-1 VERTICAL 18" GRAB BAR
TA-2 HORIZONTAL 42" GRAB BAR
TA-3 HORIZONTAL 36" GRAB BAR
TA-12 SINGLE TOLET PAPER ROLL HOLDER
TA-25 FACIAL TISSUE DISPENSER - RECESSED
TA-28 SINGLE ROBE HOOK
TA-30 TOWEL RING
TA-37 2'-6" X 1'-4" MIRROR
SCALE: 1/4" = 1'-0"
FLOOR PLAN
NORTH
SCALE: 1/4" = 1'-0"
ROOF PLAN
NORTH
DATE INITIAL
3.05 EXTERIOR WALL TO BE FILLED WITH NEW SPRAY-ON INSULATION R-20
MIN, TYPICAL
3.09 EIFS FAUX CHIMNEY BEGINS @ TRUSS BEARING
3.13 24" X 24" LIFT OUT ACCESS PANEL TO CRAWL SPACE. MFR TO PROVIDE
KEY LOCKING SECURITY DEVICE TO PREVENT UNAUTHORIZED ACCESS.
BELOW ACCESS PANEL, IN CRAWL SPACE, PROVIDE ACCESS LADDER.
MOUNT LADDER TO 2X4 WALL FROM FLOOR JOISTS TO FLOOR OF CRAWL
SPACE. ALL WOOD IN CONTACT WITH CONCRETE FLOOR SHALL BE
TREATED.
3.17 NEW 5/8" GWB ON EXTERIOR WALLS, TYP.
3.18 NEW 3/8" PLYWOOD ON EXTERIOR WALLS WITH REINSTALLED PINE
PANELING, WALL BASE, AND TRIM. PINE PANELING TO BE FURBISHED TO
MATCH ORIGINAL FOR CONSISTENT COLOR AND FINISH.
4.05 30" X 60" ROLL-IN FIBERGLASS SHOWER STALL
4.38 SOLID SURFACE COUNTERTOP WITH INTEGRAL BACKSPLASH. SCRIBE TO
WALL.
4.44 SOLID SURFACE VANITY COUNTERTOP WITH INTEGRAL SINK. OPEN
BELOW FOR ABAAS ACCESS
4.69 MICROWAVE FURNISHED BY CONTRACTOR, INSTALLED BY CONTRACTOR.
4.80 CLOSET ROD & SHELF
GENERAL NOTES
1. CONTRACTOR SHALL VERIFY WINDOW ROUGH OPENING
DIMENSIONS PER WINDOW SIZES AND PER MANUFACTURER
RECOMMENDATIONS.
ATTIC VENTILATION CALCULATIONS
ROOF AREA: 1,667 SF
RATIO: 1/300
REQUIRED: 400 SQ IN / INTAKE
400 SQ IN / EXHAUST
4 VENTS 18X12: 864 SQ IN
FIRST FLOOR
100' - 0"
T.O.,WALL
108' - 1 1/8"
A202
4"
12"
6"
12"
A202 6.06
7.07
7.14
6.19
6.20
7.06
7.14
6.19
6.20
7.40
A401
/8
7.33
FIRST FLOOR
100' - 0"
T.O.,WALL
108' - 1 1/8"
A202
6 1/2"
12"
A401 6.06
7.14
6.19
6.20
7.06
6.06
6.19
6.20
7.40
A401
FIRST FLOOR
100' - 0"
T.O.,WALL
108' - 1 1/8"
A202
A202 6.06
6.19
6.20
7.06
7.07
6.19
6.20
7.14 5.34
4"
12"
7.40
A401
/4
7.36
FIRST FLOOR
100' - 0"
T.O.,WALL
108' - 1 1/8"
A202
6 1/2"
12"
A401 6.06
6.19
7.06
6.20
7.34
6.06
7.14
6.19
7.06
6.20
7.40
A401
1044 North 115th Street | Suite 300
Omaha, NE 68154
(402) 493-4800 www.schemmer.com
REVISED TITLE OF SHEET DRAWING NO.
SHEET
PMIS / PKG. NO.
OF
SUB SHEET NO.
ARCH/ENG PROJ #
DESIGNED
DRAWN
CHECKED
PREPARED
DATE
227763 / 80111
177740
C U s e rs \b b e n tz in g e r\ D o c u m e n ts \0
-A
R C
H
R b ill
H
P G
.r v t
RJM
WEB
PJB
01/28/2022
07310.022
A201
EXTERIOR BUILDING
ELEVATIONS
07310022- 2- A201 EXTERIOR BUILDING ELEVATIONS
REHAB CEDAR PASS COTTAGE
CEDAR PASS LODGE
20681 SD-240, INTERIOR, SD 57750
SCALE: 1/4" = 1'-0"
WEST ELEVATION
SCALE: 1/4" = 1'-0"
NORTH ELEVATION
SCALE: 1/4" = 1'-0"
EAST ELEVATION
SCALE: 1/4" = 1'-0"
SOUTH ELEVATION
7.34 ELECTRICAL EQUIP. REFER TO ELECTRICAL.
7.36 MECHANICAL SUPPLY VENT. REFER TO MECHANICAL.
7.40 12"X18" THRU-WALL LOUVERED VENT WITH INSECT SCREEN. CENTER ON
GABLE.
5.34 SURFACE MOUNTED LIGHT FIXTURE. REFER TO ELECTRICAL.
6.06 SYNTHETIC COMPOSITE CEDAR SHAKE ROOFING
6.19 PREFINISHED METAL GUTTER
6.20 PREFINISHED 2" X 3" METAL DOWNSPOUT WITH EXTENSION.
7.06 EXTERIOR FINISH INSULATION SYSTEM (EFIS-1)
7.07 FAUX CHIMNEY - 2X6 FRAMING WITH EIFS FINISH (EFIS-1)
7.14 FIBER-CEMENT TEXTURED 5/4 TRIM BOARD. 8" WIDTH: PAINTED
7.33 MECHANICAL EXHAUST VENT. REFER TO MECHANICAL.
REF. NOTES ( ):X
T.O.,WALL
108' - 1 1/8"
6 1/2"
12"
LIVING
6.06
6.19
7.06
8.02
8.07
8.04
8.068.06 8.06
8.09
A302
A302
8.10
5.03
FIRST FLOOR
100' - 0"
T.O.,WALL
108' - 1 1/8"
4"
12"
A202
A401
BEDROOM 2
CLST
KITCHEN
6.06
6.19
6.20
7.06
8.04 8.02
8.02
8.14
8.068.06 8.06
8.09
8.108.10
5.03
FIRST FLOOR
100' - 0"
T.O.,WALL
108' - 1 1/8"
A202
LIVING
HALL
BEDROOM 2
8.08
7.06
8.078.04
8.13
8.02
6.06
6.19
7.06
8.06
E X
IS
T
IN
G
S O
F F
IT
8.09
8.12
8.13
8.10
8.10
5.03
1044 North 115th Street | Suite 300
Omaha, NE 68154
(402) 493-4800 www.schemmer.com
REVISED TITLE OF SHEET DRAWING NO.
SHEET
PMIS / PKG. NO.
OF
SUB SHEET NO.
ARCH/ENG PROJ #
DESIGNED
DRAWN
CHECKED
PREPARED
DATE
227763 / 80111
177740
C U s e rs \b b e n tz in g e r\ D o c u m e n ts \0
-A
R C
H
R b ill
H
P G
.r v t
RJM
WEB
PJB
01/28/2022
07310.022
A202
BUILDING SECTIONS
07310022- 2- A202 BUILDING SECTIONS
REHAB CEDAR PASS COTTAGE
CEDAR PASS LODGE
20681 SD-240, INTERIOR, SD 57750
SCALE: 1/4" = 1'-0"
BUILDING SECTION
SCALE: 1/4" = 1'-0"
BUILDING SECTION
SCALE: 1/4" = 1'-0"
BUILDING SECTION
5.03 5/8" GYPSUM BOARD CEILING ATTACHED TO BTTM OF TRUSS
6.06 SYNTHETIC COMPOSITE CEDAR SHAKE ROOFING
6.19 PREFINISHED METAL GUTTER
6.20 PREFINISHED 2" X 3" METAL DOWNSPOUT WITH EXTENSION.
7.06 EXTERIOR FINISH INSULATION SYSTEM (EFIS-1)
8.02 CONCRETE FOUNDATION WALL. REFER TO STRUCTURAL.
8.04 SPRAY-ON INSULATION WITH DEPTH NECESSARY TO ACHIEVE AN
R-VALUE OF 30
8.06 VAPOR BARRIER - VAPOR RETARDER FOR CRAWL SPACES
8.07 WOOD FLOOR JOIST. REFER TO STRUCTURAL.
8.08 WOOD ROOF TRUSS. REFER TO STRUCTURAL.
8.09 CRAWL SPACE DRAINAGE SYSTEM, REFER TO STRUCTURAL.
8.10 WATERPROOFING SYSTEM: SHEET WATERPROOFING MEMBRANE, 2" RIGID
INSULATION PROTECTION BOARD, 1/4" DRAINAGE PANEL.
8.12 WD BEAM. REFER TO STRUCTURAL.
8.13 COLUMN. REFER TO STRUCTURAL.
8.14 ADA KNEE & TOE CLEARANCES
REF. NOTES ( ):X
SEE SCHEDULE
WD : F
S E
E S
C H
E D
U L E
WD : VP
RELOCATED
SEE SCHEDULE
WD : FL
S E
E S
C H
E D
U L E
SEE SCHEDULE
S E
E S
C H
E D
U L E
24"
NEW WD
LOUVERS
PREFIN
MET
LOUVERS
SEE SCHEDULE
FG : FV3
S E
E S
C H
E D
U L E
REEDED
TEXTURED
GLASS - IG-2
WD : F1
2"
SEE SCHEDULE
2"
S E
E S
C H
E D
U L E
W1
WD
W3
WD
W4
WD
EGRESS
W5
WD
W6
WD
W2
WD
1'-9"
1'-11"
/4
2'-10 1/2"
/4
2'-1"
/4
2'-5"
/4
2'-11"
W7
WD
/4
3'-10"
W8
WD
/8
2'-7 1/2"
IG-1 IG-1 IG-1 IG-1 IG-1 IG-1 IG-1 IG-1
1044 North 115th Street | Suite 300
Omaha, NE 68154
(402) 493-4800 www.schemmer.com
REVISED TITLE OF SHEET DRAWING NO.
SHEET
PMIS / PKG. NO.
OF
SUB SHEET NO.
ARCH/ENG PROJ #
DESIGNED
DRAWN
CHECKED
PREPARED
DATE
227763 / 80111
177740
C U s e rs \b b e n tz in g e r\ D o c u m e n ts \0
-A
R C
H
R b ill
H
P G
.r v t
RJM
WEB
PBJ
01/28/2022
07310.022
A301
SCHEDULES, DOOR AND
WINDOW DETAILS
07310022- 2- A301 SCHEDULES, DOOR AND WINDOW DETAILS
REHAB CEDAR PASS COTTAGE
CEDAR PASS LODGE
20681 SD-240, INTERIOR, SD 57750
SCALE: 1/4" = 1'-0"
DOOR PANEL TYPES - WOOD (WD) & FIBERGLASS (FG)
SCALE: 1/4" = 1'-0"
DOOR FRAMEW TYPES (WD)
DOOR SCHEDULE
DOOR NO.
DOOR SIZE DOOR FRAME DETAIL
SET TYPE LABEL REMARKSWIDTH HEIGHT MATL & TYPE FINISH GLASS MATL & TYPE FINISH HEAD JAMB JAMB SILL
100-A 3' - 0" 6' - 8" FG : FV3 PAINT IG-2 WD : F1 PAINT 4/A302 5/A302 5/A302 6/A302 ENTRANCE
100-B 3' - 0" 6' - 8" WD : F STAIN - - WD : F1 STAIN 1/A302 2/A302 2/A302 PASSAGE
100-B 2' - 4" 6' - 8" WD : F STAIN - - WD : F1 STAIN 1/A302 2/A302 2/A302 PASSAGE
100-C 2' - 6" 6' - 8" WD : VP - - - - WD : F1 - - 1/A302 2/A302 2/A302 PRIVACY RELOCATED KNOTTY PINE DOOR - SALVAGE & REUSE TRIM.
REFINISH FOR A CONSISTENT COLOR AND FINISH WITH
EXISTING REINSTALLED KNOTTY PINE PANELING. REPLACE
EXISTING METAL LOUVER WITH WOOD LOUVERS TO MATCH
EXISTING WOOD.
102-B PR 2' - 0" 6' - 8" WD : F STAIN - - WD : F1 STAIN 1/A302 2/A302 2/A302 PASSAGE
104-A 3' - 0" 6' - 8" WD : F STAIN - - WD : F1 STAIN 1/A302 2/A302 2/A302 PRIVACY
104-B 3' - 0" 6' - 8" WD : FL STAIN - - WD : F1 STAIN 1/A302 2/A302 2/A302 STOREROOM
108-A 3' - 0" 6' - 8" WD : F STAIN - - WD : F1 STAIN 1/A302 2/A302 2/A302 PRIVACY UNDERCUT DOOR 3/4" FOR RETURN AIR
108-B 3' - 0" 6' - 8" WD : F STAIN - - WD : F1 STAIN 1/A302 2/A302 2/A302 PASSAGE
109 3' - 0" 6' - 8" FG : FV3 PAINT IG-2 WD : F1 PAINT 4/A302 5/A302 5/A302 6/A302 ENTRANCE
111 3' - 0" 6' - 8" FG : FV3 PAINT IG-2 WD : F1 PAINT 4/A302 5/A302 5/A302 6/A302 ENTRANCE
SCALE: 1/4" = 1'-0"
WINDOW TYPES
DATE INITIAL
GLASS TYPES
IG-1 1" INSULATED, CLEAR LOW-E GLASS
IG-2 1" INSULATED. CLEAR LOW-E, TEMPERED GLASS
5/8" GWB BOTH
SIDES ON WOOD
STUDS
2x WOOD
HEADER
WD DOOR
FRAME DOOR, SEE
SCHED
1x HARDWOOD TRIM
BOTH SIDES,
SEE 3/A302
5/8" GWB BOTH
SIDES ON WOOD
STUDS
2x WOOD
STUDS
WD DOOR
FRAME
DOOR, SEE
SCHED
1x HARDWOOD TRIM
BOTH SIDES,
SEE 3/A302
9/16"
/4
SECONDARY BARRIER
DRAINAGE MEDIUM
2" EIFS SYSTEM
/2
FLASHING
2 1/2" WOOD CASING
EIFS COMPATIBLE SEALANT
W/ CLOSED CELL BACKER
ROD PROVIDE WEEP 2' O.C.
WOOD
CASING
SECONDARY BARRIER
DRAINAGE MEDIUM
2" EIFS SYSTEM
2 1/2" WOOD CASING
EIFS COMPATIBLE SEALANT
W/ CLOSED CELL BACKER
ROD
1/2"
WOOD CASING
EXTERIOR WOOD DOOR - SEE
SCHED
AL THRESHOLD SET IN SEALANT-
THRESHOLD SHALL MEET ABAAS.
REFER TO HARDWARE SCHED.
CONC STOOP - REFER TO
STRUCT
PLWD
SHTG
WOOD
FLOORING
/4
/4
/2
SECONDARY BARRIER
DRAINAGE MEDIUM
2" EIFS SYSTEM
FLASHING
EIFS COMPATIBLE SEALANT W/
CLOSED CELL BACKER ROD.
PROVIDE WEEP 2' O.C.
WINDOW - SEE SCHED
WOOD
CASING
MEMBRANE FLASHING
W O
O D
R .O
C O
O R
D W
R
E Q
U
IR
E M
E N
T S
P E
R
W D
W M
A N
U F
WINDOW SEE SCHED
EIFS COMPATIBLE SEALANT W/ CLOSED
CELL BACKER ROD
2" EIFS SYSTEM
MEMBRANE FLASHING
DRAINAGE MEDIUM
SECONDARY BARRIER
WOOD CASING
1/2"
WOOD R.O.
COORD W/ REQUIREMENTS
PER WDW MANUF
/2
WINDOW SEE SCHED
MEMBRANE FLASHING
EIFS COMPATIBLE SEALANT W/
CLOSED CELL BACKER ROD
SECONDARY BARRIER
DRAINAGE MEDIUM
2" EIFS SYSTEM
WOOD
CASING
W O
O D
R .O
C O
O R
D W
IT
H
R E
Q U
IR
E
M E
N T
P E
R W
D W
M A
N U
F
2"
/2
/2
THIS SECTION OF EIFS TO BE
PAINTED P-6
1044 North 115th Street | Suite 300
Omaha, NE 68154
(402) 493-4800 www.schemmer.com
REVISED TITLE OF SHEET DRAWING NO.
SHEET
PMIS / PKG. NO.
OF
SUB SHEET NO.
ARCH/ENG PROJ #
DESIGNED
DRAWN
CHECKED
PREPARED
DATE
227763 / 80111
177740
C U s e rs \b b e n tz in g e r\ D o c u m e n ts \0
-A
R C
H
R b ill
H
P G
.r v t
RJM
WEB
PJB
01/28/2022
07310.022
A302
DOOR & WINDOW DETAILS
07310022- 2- A302 DOOR & WINDOW DETAILS
REHAB CEDAR PASS COTTAGE
CEDAR PASS LODGE
20681 SD-240, INTERIOR, SD 57750
SCALE: 1 1/2" = 1'-0"
INTERIOR DOOR HEAD DETAIL
SCALE: 1 1/2" = 1'-0"
INTERIOR DOOR JAMB DETAIL
SCALE: 3" = 1'-0"
DOOR TRIM
DATE INITIAL
SCALE: 3" = 1'-0"
EXTERIOR DOOR HEAD DETAIL
SCALE: 3" = 1'-0"
EXTERIOR DOOR JAMB DETAIL
SCALE: 3" = 1'-0"
EXTERIOR DOOR SILL DETAIL
SCALE: 3" = 1'-0"
WOOD WINDOW HEAD DETAIL
SCALE: 3" = 1'-0"
WOOD WINDOW JAMB DETAIL
SCALE: 3" = 1'-0"
WOOD WINDOW SILL DETAIL
-B
REF.
-A
100-C
104-B
-B
100-A
-B
DW
108-A 1
-B
F E
B
LIVING
CLST
BEDROOM 1
CLST
HALL
CLST
BATH
106 BEDROOM 2
UTIL
108 ENTRY
CLST
KITCHEN
A
W D
L V
T
L V
T W
D
ADD 1/4" PLWD
BENEATH LVT
AD…