This document provides details on a federal contract opportunity to rehabilitate Cedar Pass Cottage in Badlands National Park. The solicitation number is 140P6322B0002 and seeks to rehabilitate Cedar Pass Cottage for the National Park Service Midwest Region. Attached is a PDF of related drawings. The opportunity type is a solicitation to rehabilitate the property. No further details are provided on response dates, pricing terms, or other requirements.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SOUTH DAKOTA

SOUTHWESTERN

V.C.

HQ.

LEGEND

BADLANDS NATIONAL PARK

SCALE OF

MILES

20 0 20

TRAIL

CAMPGROUND

PICNIC AREA

AMPHITHEATER

RANGER STATION

PARK HEADQUARTERS

VISITOR CENTER

CREEK OR RIVER

FIRST AID

WILDERNESS AREA

UNPAVED ROAD

COUNTY LINE

PARK BOUNDARY

PAVED ROAD

STATE LINE

RIDGE

PINE

RESERVATION

RESERVATION

PINE

RIDGE

S A G E

L O O P

RD.

RIM R

D

CREEK

B A D L A N D S

SPRINGS

FOURCHE

SPEARFISH

HOT

BELLE

RIDGE

PINE

NEBRASKA

SOUTH

DAKOTA

WHIT

E

RIVE

R

MISSION

85 FAITH

STURGIS

C H E Y E N N E

RIV

ER

WALL 14

MURDO

OAHE

LAKE

FEE STATION

INTERIOR

STRONGHOLD

RIVER

WHITE

V.C.

UNIT

AREA

CREEK

PALMER

NORTH

UNIT

FEE STATION

PINNACLES

CEDAR PASS

LODGE

V.C.

PASS

CEDAR

HQ.

FEE STATION

NORTHEAST

BEN

REIFEL

PARK

NATIONAL

BADLANDS

SHIRT

RED

SHANNON COUNTY

PENNINGTON COUNTY

KNEE

WOUNDED

TO

J A C K S O N

C O U N T Y

S H A N N O N

C O U N T Y

W H

IT

E

R

IV

E R

TO

HERMOSA

TO

C U S

TE

R

C O U N

TY

P E N N

IN

G

TO

N

C O U N

TY

SCENIC

C H E Y E N N E

R

IV

E R

WALL

CITY

RAPID

TO

TO

PIERRE

KADOKA

J A C K S O N

C O U N T Y

P E N N

IN

G T O N

C O U N T Y

FLAT

CACTUS

INTERIOR

TO

CITY

RAPID

1044 North 115th Street | Suite 300

Omaha, NE 68154

(402) 493-4800 www.schemmer.com

REVISED TITLE OF SHEET DRAWING NO.

SHEET

PMIS / PKG. NO.

OF

SUB SHEET NO.

ARCH/ENG PROJ #

DESIGNED

DRAWN

CHECKED

PREPARED

DATE

227763 / 80111

177740

C U s e rs \b b e n tz in g e r\ D o c u m e n ts \0

-A

R C

H

R b ill

H

P G

.r v t

RJM

WEB

PJB

01/28/2022

07310.022

COVER SHEET

07310022- 0- 0 COVER SHEET

REHAB CEDAR PASS COTTAGE

CEDAR PASS LODGE

20681 SD-240, INTERIOR, SD 57750

CIVIL

C000

GENERAL

0 COVER SHEET

ACC01 ARCHITECTURAL CODE COMPLIANCE

STRUCTURAL

S 00 STRUCTURAL INFO SHEET

S 01 STRUCTURAL NOTES

S101 FOUNDATION PLAN & FRAMING PLANS

S201 TYPICAL FOUNDATION DETAILS

S202 TYPICAL FRAMING DETAILS

S203 DETAILS

S204 DETAILS

DRAWING INDEX

MECHANICAL

M 00 MECHANICAL INFO SHEET

M001 DEMOLITION FLOOR PLAN - MECHANICAL

M101 FLOOR PLAN - MECHANICAL

PLUMBING

P 00 PLUMBING INFO SHEET

P001 DEMOLITION FLOOR PLAN - PLUMBING

P101 FLOOR PLAN - PLUMBING

P301 DETAILS & SCHEDULES - PLUMBING

C000 TOPOGRAPHIC SURVEY

CO01 SITE DEMOLITION PLAN

C101 SITE LAYOUT & PAVING PLAN

C102 SITE GRADING & DRAINAGE PLAN

C201 SITE DETAILS

FINAL CD

FIRE PROTECTION

FP 00 FIRE PROTECTION INFO SHEET

FP101 FLOOR PLAN - FIRE PROTECTION

ARCHITECTURAL

A 00 ARCHITECTURAL INFO SHEET

A 000 ARCHITECTURAL INFO SHEET

A001 DEMOLITION FLOOR PLANS

A002 DEMOLITION REFLECTED CEILING PLAN & ROOF

A003 DEMOLITION PANEL PLAN

A004 DEMOLITION EXISTING CONDITIONS EXTERIOR

A005 DEMOLITION EXISTING CONDITIONS INTERIOR

A101 FLOOR PLAN, ROOF PLAN

A201 EXTERIOR BUILDING ELEVATIONS

A202 BUILDING SECTIONS

A301 SCHEDULES, DOOR AND WINDOW DETAILS

A302 DOOR & WINDOW DETAILS

A303 ROOM SCHEDULE, MATERIAL NOTES

A401 WALL SECTIONS, DETAILS

A501 MOUNTING HEIGHTS, INTERIOR ELEVATIONS &

DETAILS

A601 REFLECTED CEILING PLANS AND DETAILS

ELECTRICAL

E 00 ELECTRICAL INFO SHEET

E101 ELECTRICAL FLOOR PLANS

E201 ELECTRICAL DETAILS AND SCHEDULES

DATE INITIAL

PROJECT LOCATION

1/28/22

ELECTRICAL ENGINEER

1/28/2022

STRUCTURAL ENGINEER

1/28/2022

CIVIL ENGINEER

1/28/22

MECHANICAL ENGINEER

-B

REF.

-A

100-C

104-B

-B

100-A

-B

DW

108-A 1

-B

F E

B

E

OCCUPANCY CLASSIFICATION

RESIDENTIAL (R-1)

LIVING

CLST

BEDROOM 1

CLST

HALL

CLST

BATH

BEDROOM 2

UTIL

ENTRY

109CLST

KITCHEN

EXIT PATH: 37'-7"

2-A RATED SINGLE FIRE

EXTINGUISHER FOR LIGHT

(LOW) HAZARD OCCUPANCY.

BRACKET MOUNTED.

1044 North 115th Street | Suite 300

Omaha, NE 68154

(402) 493-4800 www.schemmer.com

REVISED TITLE OF SHEET DRAWING NO.

SHEET

PMIS / PKG. NO.

OF

SUB SHEET NO.

ARCH/ENG PROJ #

DESIGNED

DRAWN

CHECKED

PREPARED

DATE

227763 / 80111

177740

C U s e rs \b b e n tz in g e r\ D o c u m e n ts \0

-A

R C

H

R b ill

H

P G

.r v t

WEB

WEB

PJB

01/28/2022

07310.022

ACC01

ARCHITECTURAL CODE

COMPLIANCE

07310022- 0- ACC01 ARCHITECTURAL CODE COMPLIANCE

REHAB CEDAR PASS COTTAGE

CEDAR PASS LODGE

20681 SD-240, INTERIOR, SD 57750

XX FIRE BARRIER (X HOURS)

XX FIRE PARTITION (X HOURS)

XX SMOKE BARRIER (X HOURS)

XX SMOKE PARTITION (X

HOURS)

XX BUILDING SEPARATION

(X HOURS)

CODE COMPLIANCE

LEGEND

NUMBER OF OCCUPANTS

PER ROOM

DEAD-END DISTANCE

XXX'-XX"

NEW FIRE EXTINGUISHER-

INSIDE RECESSED

CABINET -(FE1)

75'

NOTES:

• CONTRACTOR SHALL PROVIDE PERMANENT

SIGNAGE OR STENCILING WITHIN CEILING

PLENUM AT ALL FIRE RATED WALLS, SMOKE

BARRIERS & SMOKE PARTITIONS. LETTERING

SHALL BE AT LEAST 1/2" IN HEIGHT WITH THE

WORDING: "FIRE AND/OR SMOKE BARRIER -

PROTECT ALL OPENINGS:. REPEAT AT

INTERVALS NOT EXCEEDING 30'-0" MEASURED

HORIZONTALLY ALONG THE PARTITION WALL.

• SEAL PENETRATIONS IN FIRE RATED SMOKE

BARRIERS, FIRE RATED BARRIERS & SMOKE

BARRIERS.

COMMON PATH DISTANCE

XXX'-XX"

OCCUPANCY ALONG PATH

ACCESSORY OCCUPANCY

INCIDENTAL OCCUPANCY

NOT HABITABLE

OCCUPANCY

CODE SUMMARY

APPLICABLE CODES

BUILDING :

ACCESSIBILITY :

LIFE SAFETY :

ENERGY :

MECHANICAL :

PLUMBING :

ELECTRICAL :

OCCUPANCY GROUP :

TYPE OF CONSTRUCTION :

MAXIMUM ALLOWED HEIGHT

MAXIMUM ALLOWED AREA

MIXED USE SEPARATIONS :

HEIGHT AND AREA LIMITS

FIRE SEPARATION ASSEMBLIES

EXITS

SHAFTS / HOISTWAYS

DWELLING UNIT SEPARATIONS

INTERIOR LOAD BEARING

WALLS, COLUMNS, FRAMING

ROOF CONSTRUCTION

FLOOR CONSTRUCTION

FIRE WALLS

EXTERIOR WALL OPENING LIMITS :

DRAFTSTOPS :

FIRE PROTECTIVE SYSTEMS

AUTO FIRE SUPPRESSION :

STANDPIPE :

FIRE ALARM SYSTEM :

AUTO FIRE DETECTION :

SMOKE DETECTION :

FIRE RESISTANCE OF STRUCTURAL

ELEMENTS

RATING

(HOURS)

DESIGN

NUMBER

EXTERIOR WALLS

LOAD BEARING WALLS

NON-LOAD BEARING WALLS

CALCULATIONS

DOOR

STAIR

R-1

V-B

120'

50,000 SF

1 HR

2015 ABAAS

NA

NFPA 13D

NA

NFPA 72

NFPA 13

NFPA 72

2009 NFPA 101

2018 IECC

2018 IMC

2021 UPC

2020 NEC

2021 IBC / 2021 IEBC

UL

UL

UL

UL

UL

UL

UL

UL

UL

-.-" / OCC

-.-" / OCC

PLUMBING FIXTURE

REQUIREMENTS

MEN - REQUIRED

WOMEN - REQUIRED

MEN - PROVIDED

WOMEN - PROVIDED

NUMBER OF OCCUPANTS

MEN

WOMEN

WC LAV URINALS

TUB/

SHOWER

DRINKING FOUNTAINS

REQUIRED

PROVIDED

OCC TYPE

1 PER 50 2 PER 50 - - 1 PER 8

1 PER 100

FIRST FLOOR

SECOND FLOOR

TOTAL

AREA (GROSS SQUARE FOOTAGE) :

BUILDING STATISTICS

NUMBER OF STORIES :

THIRD FLOOR

FOURTH FLOOR

SUBGRADE

1091 SF

0 SF

1091 SF

0 SF

0 SF

0 SF

ACC_ROOM SCHEDULE

ROOM NO ROOM NAME FUNCTION OF SPACE CALC (SQF/OCC) OCCUPANT LOAD

AREA / OCC

FIRST FLOOR

RESIDENTIAL (R-1)

100 LIVING 337 SF

101 CLST 6 SF

102 BEDROOM 1 143 SF

103 CLST 10 SF

104 HALL 54 SF

105 CLST 8 SF

106 BATH 61 SF

107 BEDROOM 2 122 SF

108 UTIL 14 SF

109 ENTRY 16 SF

110 CLST 11 SF

111 KITCHEN 159 SF

: 12 0

RESIDENTIAL (R-1): 12 0

FIRST FLOOR: 12 0

TOTALS:: 12 0

SCALE: 1/4" = 1'-0"

FIRST FLOOR - CODE REVIEW PLAN

1091 SF GROSS

NORTH

DATE INITIAL

1044 North 115th Street | Suite 300 Omaha, NE 68154

(402) 493-4800 www.schemmer.com

REVISED TITLE OF SHEET DRAWING NO.

SHEET

PMIS / PKG. NO.

OF

SUB SHEET NO.

ARCH/ENG PROJ #

DESIGNED

DRAWN

CHECKED

PREPARED

DATE

DATE INITIAL

REHAB CEDAR PASS COTTAGE

CEDAR PASS LODGE

20681 SD-240, INTERIOR, SD 57750

227763 / 80111

177740

07310.022

01/28/2022 42

WJ TOPOGRAPHIC SURVEY

C000

(402) 493-4800 www.schemmer.com

REVISED TITLE OF SHEET DRAWING NO.

SHEET

PMIS / PKG. NO.

OF

SUB SHEET NO.

ARCH/ENG PROJ #

DESIGNED

DRAWN

CHECKED

PREPARED

DATE

DATE INITIAL

REHAB CEDAR PASS COTTAGE

CEDAR PASS LODGE

20681 SD-240, INTERIOR, SD 57750

227763 / 80111

177740

07310.022

01/28/2022 42

MJS

DJK SITE DEMOLITION PLAN

C0011044 North 115th Street | Suite 300

Omaha, NE 68154

(402) 493-4800 www.schemmer.com

REVISED TITLE OF SHEET DRAWING NO.

SHEET

PMIS / PKG. NO.

OF

SUB SHEET NO.

ARCH/ENG PROJ #

DESIGNED

DRAWN

CHECKED

PREPARED

DATE

DATE INITIAL

REHAB CEDAR PASS COTTAGE

CEDAR PASS LODGE

20681 SD-240, INTERIOR, SD 57750

227763 / 80111

177740

07310.022

01/28/2022 42

MJH

1/28/2022

(402) 493-4800 www.schemmer.com

REVISED TITLE OF SHEET DRAWING NO.

SHEET

PMIS / PKG. NO.

OF

SUB SHEET NO.

ARCH/ENG PROJ #

DESIGNED

DRAWN

CHECKED

PREPARED

DATE

DATE INITIAL

REHAB CEDAR PASS COTTAGE

CEDAR PASS LODGE

20681 SD-240, INTERIOR, SD 57750

227763 / 80111

177740

07310.022

01/28/2022 42

MJS

DJK

C101

SITE LAYOUT & PAVING

PLAN

(402) 493-4800 www.schemmer.com

REVISED TITLE OF SHEET DRAWING NO.

SHEET

PMIS / PKG. NO.

OF

SUB SHEET NO.

ARCH/ENG PROJ #

DESIGNED

DRAWN

CHECKED

PREPARED

DATE

DATE INITIAL

REHAB CEDAR PASS COTTAGE

CEDAR PASS LODGE

20681 SD-240, INTERIOR, SD 57750

227763 / 80111

177740

07310.022

01/28/2022 42

MJS

DJK

C102

SITE GRADING & DRAINAGE

PLAN

(402) 493-4800 www.schemmer.com

REVISED TITLE OF SHEET DRAWING NO.

SHEET

PMIS / PKG. NO.

OF

SUB SHEET NO.

ARCH/ENG PROJ #

DESIGNED

DRAWN

CHECKED

PREPARED

DATE

DATE INITIAL

REHAB CEDAR PASS COTTAGE

CEDAR PASS LODGE

20681 SD-240, INTERIOR, SD 57750

227763 / 80111

177740

07310.022

01/28/2022 42

MJS

DJK

MJH C201

SITE DETAILS

(402) 493-4800 www.schemmer.com

REVISED TITLE OF SHEET DRAWING NO.

SHEET

PMIS / PKG. NO.

OF

SUB SHEET NO.

ARCH/ENG PROJ #

DESIGNED

DRAWN

CHECKED

PREPARED

DATE

227763 / 80111

177740

C U s e rs \b b e n tz in g e r\ D o c u m e n ts \0

-A

R C

H

R b ill

H

P G

.r v t

PJB

WEB

PJB

01/28/2022

07310.022

A 00

ARCHITECTURAL INFO SHEET

07310022- 2- A 00 ARCHITECTURAL INFO SHEET

REHAB CEDAR PASS COTTAGE

CEDAR PASS LODGE

20681 SD-240, INTERIOR, SD 57750

0 COVER SHEET

ACC01 ARCHITECTURAL CODE

COMPLIANCE

A 00 ARCHITECTURAL INFO SHEET

A 000 ARCHITECTURAL INFO SHEET

A001 DEMOLITION FLOOR PLANS

A002 DEMOLITION REFLECTED CEILING

PLAN & ROOF

A003 DEMOLITION PANEL PLAN

A004 DEMOLITION EXISTING

CONDITIONS EXTERIOR

A005 DEMOLITION EXISTING

CONDITIONS INTERIOR

A101 FLOOR PLAN, ROOF PLAN

A201 EXTERIOR BUILDING ELEVATIONS

A202 BUILDING SECTIONS

A301 SCHEDULES, DOOR AND WINDOW

DETAILS

A302 DOOR & WINDOW DETAILS

A303 ROOM SCHEDULE, MATERIAL

NOTES

A401 WALL SECTIONS, DETAILS

A501 MOUNTING HEIGHTS, INTERIOR

ELEVATIONS & DETAILS

A601 REFLECTED CEILING PLANS AND

DETAILS

A. THE DEMOLITION PLANS WERE PRODUCED BY DUPLICATING THE ORIGINAL

DRAWINGS PROVIDED BY THE OWNER AND LIMITED FIELD VERIFICATION.

DIMENSIONS AND EXISTING CONDITIONS ARE APPROXIMATE. CONTRACTOR

SHALL FIELD VERIFY EXISTING CONDITIONS. ITEMS WHICH ARE INTENDED

TO BE REMOVED, RELOCATED, OR SALVAGED ARE SHOWN AS FULL-TONE

DASHED LINES AND ARE LISTED IN THE REFERENCED DEMOLITION NOTES.

ALL OTHER ITEMS ARE INTENDED TO REMAIN IN PLACE AND ARE SHOWN

HALF-TONE.

B. DEMOLITION SHALL INCLUDE, BUT IS NOT LIMITED TO, THE ITEMS BELOW OR

HERE-IN. THE CONTRACTOR SHALL COORDINATE ALL REQUIRED

RENOVATION AND NEW CONSTRUCTION WITH THE EXISTING BUILDING TO

IDENTIFY THE TOTAL EXTENT OF THE DEMOLITION REQUIRED AND AS LISTED

BELOW.

C. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE DEMOLITION AND

REMOVAL OF ALL EXISTING BUILDING COMPONENTS, MATERIALS,

EQUIPMENT, AND APPURTENANCES AS REQUIRED TO BUILD, ERECT,

INSTALL, OR ACCOMMODATE ALL NEW CONSTRUCTION WITH THE OWNER

HAVING FIRST RIGHT OF REFUSAL ON ALL ITEMS.

D. ITEMS NOTED TO BE REMOVED AND SALVAGED OR REINSTALLED SHALL BE

CAREFULLY REMOVED BY THE CONTRACTOR WITHOUT DAMAGE AND

STORED OR REINSTALLED ON THE SITE AS DIRECTED. REMOVED AND

SALVAGED ITEMS SHALL REMAIN THE PROPERTY OF THE OWNER.

E. WHERE EXISTING FLOOR MATERIALS AND/OR WALLS ARE TO BE REMOVED,

PREP REMAINING FLOOR AND/OR WALL SUBSTRATE AS REQUIRED PER

MANUFACTURERS RECOMMENDATIONS FOR THE NEW FLOOR/WALL FINISH

MATERIAL. REMOVE ALL FINISH FLOORING DOWN TO BASE SUBSTRATE

FLOORING AND PREP TO RECEIVE NEW FINISH.

F. THE CONTRACTOR IS RESPONSIBLE FOR THE ERECTION, MAINTENANCE,

AND REMOVAL OF ALL CONSTRUCTION BARRIERS.

G. TEMPORARILY SHORE AND BRACE STRUCTURE AT ALL BEARING WALL

DEMOLITION LOCATIONS UNTIL NEW PERMANENT STRUCTURE IS

ESTABLISHED. SEE STRUCTURAL.

H. REMOVE EXISTING ELEMENTS/FINISHES NOT REQUIRED IN THE COMPLETED

PROJECT, BUT CONFLICTING WITH NEW FINISHES. THESE

ELEMENTS/FINISHES SHALL INCLUDE, BUT ARE NOT LIMITED TO THE ITEMS

LISTED BELOW:

1. ALL EXISTING WALLS, DOORS, FRAMES, AND WINDOWS SHOWN ON THE

PLAN AS A FULL-TONE DASHED LINE ARE TO BE REMOVED.

I. SEE STRUCTURAL, MECHANICAL, AND ELECTRICAL DRAWINGS FOR

ADDITIONAL DEMOLITION, INCLUDING, BUT NOT LIMITED TO, ALL CONCRETE

SLAB REMOVAL AND REPLACEMENT.

J. REFER TO MECHANICAL DEMOLITION PLANS FOR ADDITIONAL DEMOLITION

REQUIRED TO ACCOMMODATE NEW MECHANICAL PIPING AND ASSOCIATED

EQUIPMENT.

K. SEE CIVIL DRAWINGS FOR EXTENT OF SITE DEMOLITION WORK.

A. EXISTING CONDITIONS ARE BASED ON DRAWINGS PROVIDED BY THE OWNER

AND LIMITED FIELD VERIFICATION. THE CONTRACTOR SHALL FIELD VERIFY

ALL EXISTING CONDITIONS AND DIMENSIONS AND NOTIFY THE

ARCHITECT/ENGINEER OF ANY DISCREPANCIES OR VARIATIONS FROM

THOSE SHOWN ON THE DRAWINGS. THE CONTRACTOR SHALL ADJUST TO

ACTUAL FIELD CONDITIONS.

B. CONTRACTOR SHALL TAKE ALL MEASUREMENTS FOR WORK AND BE

RESPONSIBLE FOR SAME. CONTRACTOR SHALL ADJUST FOR ACTUAL FIELD

CONDITIONS. COORDINATE THE WORK AND SHOP DRAWINGS WITH ALL

OTHER TRADES AFFECTED.

C. SCREENED HALF-TONE LINES INDICATE EXISTING CONSTRUCTION TO

REMAIN. FULL-TONE LINES INDICATE NEW OR RELOCATED CONSTRUCTION.

D. BUILDING ELEVATION 2437.0' ON THE SITE PLAN EQUALS ELEVATION 100'-0"

ON THE ARCHITECTURAL PLANS.

E. DIMENSIONS ARE TYPICALLY TO FINISH FACE OF MASONRY, CONCRETE,

GYPSUM WALL BOARD, AND METAL FRAMES; OR CENTER LINE OF COLUMN

OR BEAMS, UNLESS NOTED OTHERWISE.

F. INTERIOR DOORS WITH THE HINGE-SIDE SHOWN CLOSE TO CORNERS SHALL

BE LOCATED 4 INCHES FROM ADJACENT WALL UNLESS NOTED OTHERWISE

G. CHANGES IN FLOOR MATERIALS SHALL OCCUR UNDER DOORS.

a. PROVIDE POSITIVE DRAINAGE TO ALL ROOMS WITH NEW FLOOR DRAINS

H. ALL ANGLES ON THE FLOOR PLANS ARE 45 OR 90 DEGREES UNLESS

OTHERWISE INDICATED.

I. PROVIDE FIRE TREATED 2x6 OR LARGER WOOD BLOCKING IN WALLS AND

FURRING SPACES AS REQUIRED FOR MOUNTING OF ALL WALL SUPPORTED

ITEMS. WHETHER OR NOT DETAILED ON THE DRAWINGS, THE DRYWALL

CONTRACTOR SHALL COORDINATE AND INSTALL ALL STIFFENERS, BRACING,

BACK-UP PLATES, AND SUPPORTING BRACKETS AS REQUIRED FOR THE

INSTALLATION OF CASEWORK AND WALL MOUNTED OR SUSPENDED

MECHANICAL, ELECTRICAL, OR MISCELLANEOUS EQUIPMENT. THESE ITEMS

INCLUDE, BUT ARE NOT LIMITED TO, HANDRAIL BRACKETS, DOOR WALL

STOPS, FIRE EXTINGUISHER CABINETS, VANITY TOPS, BASE AND WALL

CABINETS, COUNTERTOPS, CONTROL PANELS, WATER COOLERS, WALL

HUNG SINKS, URINALS, TOILETS, MIRRORS, SOAP DISPENSERS, PAPER

TOWEL DISPENSERS, NAPKIN DISPOSAL, TOILET PARTITIONS, URINAL

SCREENS, TOILET PAPER DISPENSERS, SIGNAGE, GRAB BARS, FIRE ALARM

PANELS AND MASTER CLOCKS, ETC.

J. INTERIOR CONTROL JOINTS ON GYPSUM BOARD SURFACES SHALL BE 24'-0"

ON CENTER MAX AND AS INDICATED WITH-IN. PROVIDE CONTROL JOINT AT

EACH SIDE OF DOOR FRAME, TYPICAL.

K. ALL CONTROL JOINTS (CJ) SHALL BE CAULKED AT EXTERIOR WALL

LOCATIONS AND RAKED BACK 3/4 INCH AT ALL INTERIOR JOINTS UNLESS

OTHERWISE NOTED.

L. PATCH EXISTING WALLS, FLOORS, AND CEILING SURFACES DEMOLISHED,

CUT, CORED, OR ALTERED IN ANY WAY TO ACCOMMODATE NEW

CONSTRUCTION OR TO RECEIVE NEW FINISHES. PREP ALL EXISTING

FLOORS TO RECEIVE NEW FINISHES PER ROOM FINISH SCHEDULE.

M. SEE SHEET A301 FOR DOOR AND ROOM FINISH SCHEDULES.

N. SEE SHEET A101 FOR PARTITION TYPES AND NOTES.

O. ANY EXCAVATION BY THE CONTRACTOR SHALL BE COORDINATED WITH THE

BADLANDS NATIONAL PARK SERVICE AND COR FOR PALEONTOLOGY

SCREENING.

TRUE

NORTH

PLAN

NORTH

NORTH

NORTH

ARROW

NAME

ELEVATION

LEVEL

MATCHLINE

AREA A

AREA B

TITLE

MARKER

VIEW NAME

SCALE: 1/8" = 1'-0"

EXISTING

COLUMN

NEW

COLUMN

X

X

X

XX-XX

SIM

X

XX-XX

XXXX

DX

X

SECTION/

DETAIL

PLAN

DETAIL

REFERENCE

NOTE

REFERENCE

DEMOLITION

NOTE

EQUIPMENT

NUMBER

ROOM NAME

150 SF

ROOM

NUMBER

LETTER INDICATES

NEW COLUMN LINE

LETTER INDICATES

EXISTING COLUMN LINE

SECTION/DETAIL

NUMBER

SHEET NUMBER

INDICATES DIRECTION

OF VIEW

DETAIL NUMBER

SHEET NUMBER

REFERENCE

DESIGNATION

DEMOLITION

DESIGNATION

EQUIPMENT

NUMBER

ROOM NAME

DESIGNATION

ROOM NUMBER

DESIGNATION

ROOM AREA

DESIGNATION

ROOM /

FRAMING

ELEVATION

EXTERIOR

ELEVATION

XX-XX

XX-XX

ELEVATION LETTER

DIRECTION OF VIEW

SHEET NUMBER

ELEVATION LETTER

DIRECTION OF VIEW

SHEET NUMBER

DOOR

NUMBER

DOOR NUMBER10

WINDOW

DESIGNATION

WINDOW DESIGNATION000

TA-X

TOILET

ACCESSORY

TOILET ACCESSORY

NUMBER

WALL

TYPE

LETTER

INDICATES

PARTITION OR

WALL TYPE

X

DETAIL NUMBER

LEVEL CALLOUT

DESIGNATION

ELEVATION

DESIGNATION

GRAPHIC AREA FOR

DRAWING

TITLE

SCALE OF THE

DRAWING

ABBREVIATIONSREFERENCE LEGEND

ARCHITECTURAL SHEET LIST

GENERAL NOTESGENERAL DEMO NOTES

S SOUTH

SA SUPPLY AIR

SAN SANITARY

SB SECURITY BARS

SB SPLASH BLOCK

SCH SCHEDULE

SCHED SCHEDULE

SCR SCREW

SCT STRUCTURAL CLAY TILE

SCUT SCUTTLE

SCW SOFT COLD WATER

SD STORM DRAIN

SD SUBDRAIN

SDI STEEL DECK INSTITUTE

SECT SECTION

SECY SECRETARY

SEQ SEQUENCE

SF SQUARE FOOT (FEET)

SFU STRUCTURAL FACING

UNIT

SHLD SHOULDER

SHT SHEET

SHTG SHEATHING

SHW SOFT HOT WATER

SIM SIMILAR

SJI STEEL JOIST INSTITUTE

SL SNOW LOAD

SLBB SHORT LEG BACK TO

BACK

SM SPRINKLER MAIN

SOV SHUT OFF VALVE

SPA SPACE(ING)

SPEC SPECIFICATIONS

SPF SOUNDPROOF

SPH SPACE HEATER

SPKR SPEAKER

SPL SPECIAL

SQ SQUARE

SS SANITARY SEWER

SS STAINLESS STEEL

SSMR STANDING SEAM METAL

ROOFING

STA STATION

STAIR STAIRWAY

STC SOUND TRANSMISSION

COEFFICIENT

STD STANDARD

STGR STRINGER

STIFF STIFFENER

STIRR STIRRUPS

STL STEEL

STN STONE

STOR STORAGE

STR STRUCTURAL

SUB FL SUB FLOOR

SUCT SUCTION

SUSP SUSPENDED

SVF SHEET VINYL FLOORING

SW SWITCH

SWBD SWITCH BOARD

SYM SYMMETRICAL

T TREAD

T or TLT TOILET

TAN TANGENT

TBD TACK BOARD

TE TOP ELEVATION

TEL TELEPHONE

TEMP TEMPERATURE

TER TERRAZZO

TERM TERMINAL

TGL TOGGLE

TH THRESHOLD

THK THICK

THRD THREAD

TO TOP OF

TOB TOP OF BEAM

TOC TOP OF CONCRETE

TOF TOP OF FOOTING

TOJ TOP OF JOIST

TOPO TOPOGRAPHIC

TOS TOP OF STEEL

TOW TOP OF WALL

TRANS TRANSVERSE

TSTAT THERMOSTAT

TV TELEVISION

TW TEMPERED WATER

TWR TEMPERED WATER

RETURN

TYP TYPICAL

UC UNIT COOLER

UG UNDERGROUND

UH UNIT HEATER

UL UNDERWRITERS

LABORATORIES

UNEX UNEXCAVATED

UNFIN UNFINISHED

UNO UNLESS NOTED

OTHERWISE

UPS UNINTERRUPTIBLE

POWER SYSTEM

UR URINAL

UT UTILITY

UV UNIT VENTILATOR

V VOLT

VAC VACUUM

VAV VARIABLE AIR VOLUME

VCP VITRIFIED CLAY PIPE

VCT VINYL COMPOSITION TILE

VD VAULT DOOR

VEL VELOCITY

VENT VENTILATOR(ION)

VERT VERTICAL

VEST VESTIBULE

VFD VARIABLE FREQUENCY

DRIVE

VOL VOLUME

VPC VERTICAL POINT OF

CURVATURE

VPI VERTICAL POINT OF

INTERSECTION

VPT VERTICAL POINT OF

TANGENCY

VS VENT STACK

VT VINYL-TILE

VTR VENT THRU ROOF

VWC VINYL WALL COVERING

W WEST

W WIDE (WIDTH)

W WIRE

W/ WITH

W/O WITHOUT

WB WET BULB

WC WATER CLOSET

WC WATER COLUMN

WD WASTE DRAIN

WD WOOD

WD BLKG WOOD BLOCKING

WD DR WOOD DOOR

WDW WINDOW

WF WIDE FLANGE

WG WIRE GLASS

WH WALL HYDRANT

WHT WHITE

WI WROUGHT IRON

WKSH WORK SHOP

WL WIND LOAD

WNSCT WAINSCOT

WP WEATHER PROOF

WP WORK POINT

WPF WATER PROOF

WPFG WATER PROOFING

WRB WARDROBE

WS WASTE STACK

WT WEIGHT

WWF WELDED WIRE FABRIC

WWM WOVEN WIRE MESH

XFMR TRANSFORMER

YD YARD or YARD DRAIN

LBS POUNDS

LD LOAD

LDG LOADING

LE LEFT END

LG LENGTH (LONG)

LIN LINEAR

LIS LAWN IRRIGATION

SYSTEM

LL LIVE LOAD

LLBB LONG LEG BACK TO BACK

LLH LONG LEG HORIZONTAL

LLV LONG LEG VERTICAL

LNTL LINTEL

LP LOW POINT

LPG LIQUIFIED PETROLEUM

GAS

LPS LOW PRESSURE STEAM

LR LIVING ROOM

LS LAWN SPRINKLER

LT LIGHT

LT WT LIGHT WEIGHT

LTG LIGHTING

LVT LUXURY VINYL TILE

M MIDDLE

M THOUSAND

M & B MATCHED AND BEADED

MA MAKE-UP AIR

MACH MACHINE

MAS MASONRY

MAT or

MATL

MATERIAL

MAX MAXIMUM

MB MACHINE BOLT

MBH 1000 BTUH

MC MEDICINE CABINET

MC MISCELLANEOUS

CHANNELS

MECH MECHANICAL

MER MECHANICAL EQUIPMENT

ROOM

MET METAL

MFG MANUFACTURING

MFR MANUFACTURER

MH MANHOLE

MIN MINIMUM

MISC MISCELLANEOUS

ML METAL LATH

MLDG MOULDING

MO MASONRY OPENING

MONO MONOLITHIC

MT METAL THRESHOLD

MTD MOUNTED

N NORTH

NC NORMALLY CLOSED

NEC NATIONAL ELECTRICAL

CODE

NEMA NATIONAL ELECTRICAL

MANUFACTURERS

ASSOCIATION

NFPA NATIONAL FIRE

PROTECTION

ASSOCIATION

NIC NOT IN CONTRACT

NO NORMALLY OPEN

NO NUMBER

NR NOT REQUIRED

NS NEAR SIDE

NTS NOT TO SCALE

OA OUTSIDE AIR

OB WG OBSCURE WIRE GLASS

OBGL OBSCURE GLASS

OBSC OBSCURE

OC ON CENTER(S)

OCEW ON CENTER EACH WAY

OD OUTSIDE DIAMETER

OFF OFFICE

OH OVERHEAD

OPNG OPENING

OPP OPPOSITE

OPS OPERATIONS

OS & Y OUTSIDE SCREW & YOKE

OSF OUTSIDE FACE

OV OVERFLOW VALVE

OX OXYGEN

OZ OUNCE

P PAINT

PA PUBLIC ADDRESS

PBS PUSH BUTTON STATION

PC PIECE

PC POINT OF CURVATURE

PC PRECAST

PCC PORTLAND CEMENT

CONCRETE

PCT PORCELAIN CERAMIC TILE

PD PRESSURE DROP

PE POLYETHYLENE

PEN PENETRATION

PERF PERFORATED

PH PHASE

PHAR PHARMACY

PI POINT OF INTERSECTION

PIV POST INDICATING VALVE

PL or P PLATE

PLAM PLASTIC LAMINATE

PLAS PLASTER

PLATF PLATFORM

PLBG PLUMBING

PLG PILING

PLWD PLYWOOD

PNL PANEL

POL POLISH(ED)

PORC PORCELAIN

PPM PARTS PER MILLION

PR PAIR

PREFAB PREFABRICATED

PREFIN PREFINISHED

PRESS PRESSURE

PROJ PROJECT

PRV PRESSURE REGULATING

VALVE

PS PRESSED STEEL

PSFT POUNDS PER SQUARE

FOOT

PSI POUNDS PER SQUARE

INCH

PT POINT

PT POINT OF TANGENCY

PTD PAINTED

PTN PARTITION

PVC POLYVINYL-CHLORIDE

PVMT PAVEMENT

PW PASS WINDOW

1/4 RD QUARTER ROUND

QT QUARRY TILE

QT QUART

QTRS QUARTERS

QTY QUANTITY

QTZ QUARTZ

R REGISTER

R RISER

RA RETURN AIR

RAD OR

R

RADIUS

RB RESILIENT BASE

RC REMOTE CONTROL

RCP REINFORCED CONCRETE

PIPE

RD ROOF DRAIN

RE RIGHT END

REC RECEIVER

RECP RECEPTACLE

RECR RECREATION

RECT RECTIFIER

REF REFERENCE

REFR REFRIGERANT

REFR REFRIGERATOR

REG REGISTER

REINF REINFORCEMENT

REM REMOVE(ABLE)

REQD REQUIRED

RESIL RESILIENT

REV REVISIONS

RFG ROOFING

RH RELATIVE HUMIDITY

RL REFRIGERANT LIQUID

RM ROOM

RND ROUND

RO ROUGH OPENING

RPM REVOLUTIONS PER

MINUTE

RT RUBBER TILE

RTU ROOF TOP UNIT

RUB RUBBER

DIAG DIAGONAL

DIM DIMENSION

DIP DUCTILE IRON PIPE

DISC DISCONNECT

DIST DISTRIBUTION

DL DEAD LOAD

DMPR DAMPER

DN DOWN

DP DAMP PROOFING

DPT DEW POINT

DR DOOR

DRN DRAIN

DS DOWN SPOUT

DV DENTAL VACUUM

DWG DRAWING

DWLS DOWELS

DX DIRECT EXPANSION

E EAST

EA EACH

EA EXHAUST AIR

EDH ELECTRIC DUCT HEATER

EER ENERGY EFFICIENCY

RATIO

EJ EXPANSION JOINT

EL OR

ELEV

ELEVATION - GRADE OR

BUILDING

ELEC ELECTRIC OR ELECTRICAL

ELEV ELEVATOR

ENCL ENCLOSURE

ENT ENTERING

ENT ENTRANCE

EQ EQUAL

EQUIP EQUIPMENT

ES EACH SIDE

EST ESTIMATE

EVAP EVAPORATOR

EW EACH WAY

EWC ELECTRIC WATER

COOLER

EXC EXCAVATE

EXD EXIT DEVICE

EXH EXHAUST

EXIST EXISTING

EXP EXPOSED

EXPL EXPLOSION

EXPN EXPANSION

EXT EXTERIOR

F FAHRENHEIT

F FIRE

FA FRESH AIR

FCG FACING

FD FLOOR DRAIN

FDN FOUNDATION

FE FIRE EXTINGUISHER

FEB FIRE EXTINGUISHER

BRACKET

FEC FIRE EXTINGUISHER

CABINET

FH FIRE HYDRANT

FHC FIRE HOSE CABINET

FIG FIGURE

FIN FINISH

FIX FIXTURE

FL or FLR FLOOR

FLASH FLASHING

FLEX FLEXIBLE

FLG FLANGE

FLG FLOORING

FLUOR FLUORESCENT

FP FIRE PROTECTION

FPM FEET PER MINUTE

FPRF FIRE PROOF

FR FRAME

FRG FURRING

FS FAR SIDE

FS FLOOR SINK

FS FULL SIZE

FT FEET (FOOT)

FTG FOOTING

FV FIELD VERIFY

FWC FABRIC WALL COVERING

G GRILLE

G NATURAL GAS

GA GAGE OR GAUGE

GAL GALLON

GALV GALVANIZED

GEN GENERAL

GFE GOVERNMENT FURNISHED

EQUIPMENT

GFE/CI GOVERNMENT FURNISHED

EQUIPMENT/CONTRACTOR

INSTALLED

GFI GROUND FAULT

INTERRUPTER

GI GALVANIZED IRON

GL GLASS

GND GROUND

GOVT GOVERNMENT

GPH GALLONS PER HOUR

GPM GALLONS PER MINUTE

GR GRADE

GRS GALVANIZED RIGID STEEL

CONDUIT

GRTG GRATING

GSU GLAZED STRUCTURAL

UNITS

GWB GYPSUM WALLBOARD

GWT GLAZED WALL TILE

GYP GYPSUM

H or HT HEIGHT (HIGH)

HB HOSE BIBB

HBD HARDBOARD

HC HANDICAPPED

HD HEAD

HDPE HIGH DENSITY

POLYETHYLENE

HDR HEADER

HDW HARDWARE

HIP HIGH PRESSURE

HM HOLLOW METAL

HORIZ HORIZONTAL(LY)

HP HORSE POWER

HPS HIGH PRESURE STEAM

HPT HIGH POINT

HR HOUR

HS HIGH STRENGTH

HSGYP HIGH STRENGTH GYPSUM

PLASTER

HTG HEATING

HTR HEATER

HW HEAD WALL

HW HOT WATER

HWH HOT WATER HEATER

HWR HOT WATER RETURN

(HEATING)

HWS HOT WATER SUPPLY

(HEATING)

HYD HYDRAULIC

I or FE IRON

IC INTERCOM

ID INSIDE DIAMETER

IE INVERT ELEVATION

IES ILLUMINATING

ENGINEERING SOCIETY

IN INCH

INSUL INSULATION

INT INTERIOR

INV INVERT OR INVERTER

IP IRON PIPE

ISF INSIDE FACE

JB JUNCTION BOX

JBOX JUNCTION BOX

JC JANITOR CLOSET

JCT JUNCTION

JST JOIST

JT JOINT

K KEY

KCP KEENE'S CEMENT

PLASTER

KIP or K KILOPOUND (1000 LBS)

KIT KITCHEN

KL KEY LOCK

KP KICK PLATE

KV KILOVOLTS

KVA KILOVOLT AMPERES

KW KILOWATT

LAB LABORATORY

LAU LAUNDRY

LAV LAVATORY

LBR LUMBER

A COMPRESSED AIR

A/C AIR CONDITIONING

AB ANCHOR BOLT

ABS ACRYLONITRILE BUTAD

STYRENE

AC ALTERNATING CURRENT

ACI AMERICAN CONCRETE

INSTITUTE

ACSR ALUMINUM CONDUCTOR

STEEL REINFORCED

ACST ACOUSTIC

AD ACCESS DOOR

AD AREA DRAIN

ADMIN ADMIN ADMINISTRATION

(IVE)

AFF ABOVE FINISH FLOOR

AFFF AQUEOUS FILM FORMING

FOAM

AGG AGGREGATE

AHU AIR HANDLING UNIT

AI AREA INLET

AIC AMPS INTERRUPTING

CAPACITY (SYM RMS)

AISC AMERICAN INSTITUTE OF

STEEL CONSTRUCTION

AL ACTIVE LEAF

AL ALUMINUM

ALT ALTERNATE

AMP AMPERE

ANSI AMERICAN NATIONAL

STANDARDS INSTITUTE

AP ACCESS PANEL

APD AIR PRESSURE DROP

APPD APPROVED

APPROX APPROXIMATE

ARCH ARCHITECTURAL OR

ARCHITECT

ARI AMERICAN

REFRIGERATION

INSTITUTE

ASB ASBESTOS

ASPH ASPHALT

APC ACOUSTICAL PANEL

CEILING

AUTO AUTOMATIC

AV ACID VENT

AVG AVERAGE

AW ACID WASTE

AWC ACOUSTICAL WALL

COVERING

AWG AMERICAN WIRE GAUGE

L ANGLE

BATT BATT INSULATION

BB BULLETIN BOARD

BBO BOILER BLOW OFF

BC BOOKCASE

BD BOARD

BDY BOUNDARY

BEJ BRICK EXPANSION JOINT

BIT BITUMINOUS

BKR BREAKER

BL BUILDING LINE

BLDG BUILDING

BLK BLOCK

BLKG BLOCKING

BM BEAM

BM BENCH MARK

BO BOTTOM OF

BOT BOTTOM

BRCG BRACING

BRDG BRIDGING

BRG BEARING

BRK BRICK

BRKT BRACKET

BS BOTH SIDES

BTU BRITISH THERMAL UNIT

BTUH BTU PER HOUR

BUR BUILT-UP ROOFING

BW BOTH WAYS

C CENTER

C OR

CND

CONDUIT (ELECTRICAL

SHEETS)

C TO C CENTER TO CENTER

CAP CAPACITY

CB CATCH BASIN (OR CIRCUIT

BREAKER)

CC CENTER TO CENTER

CCT CIRCUIT

CD CONDENSATE DRAIN

CE COVER ELEVATION

CEM CEMENT

CF CUBIC FEET

CFH CUBIC FEET PER HOUR

CFM CUBIC FEET PER MINUTE

CHIM CHIMNEY

CI CAST IRON

CI CURB INLET

CIP CAST IN PLACE

CIR CIRCULAR

CJ CONTROL JOINT

CKT CIRCUIT

CL CENTER LINE

CL WG CLEAR WIRE GLASS

CLG CEILING

CLKG CAULKING

CMP CORRUGATED METAL PIPE

CMU CONCRETE MASONRY

UNIT

CNTR COUNTER

CO CLEAN OUT

CO2 CARBON DIOXIDE

COL COLUMN

COM COMMON

COMB COMBINATION

COMB COMBUSTION

COMP COMPRESSIBLE

COMPR COMPRESSOR

CONC CONCRETE

CONF CONFERENCE

CONN CONNECTION

CONSTR CONSTRUCTION

CONSTR

JT

CONSTRUCTION JOINT

CONT CONTINUOUS

(CONTINUATION)

CONTR CONTRACTOR

COR CORNER

CORR COVERED

COV CORRIDOR

CPL CEMENT PLASTER

CPS CYCLES PER SECOND

(HERTZ)

CPT CARPET

CR CONDENSER WATER

RETURN

CRES CORROSIVE RESISTANT

STEEL

CRG CARRIAGE

CRSE COURSE

CS CONDENSER WATER

SUPPLY

CS COUNTER SINK

CSMT CASEMENT

CT CERAMIC TILE

CT CURRENT TRANSFORMER

CTL CARPET TILE

CU CONDENSING UNIT

CU YD CUBIC YARDS

CUH CABINET UNIT HEATER

CV CEILING VENT

CW COLD WATER

CWR CHILLED WATER RETURN

CWS CHILLED WATER SUPPLY

CYL CYLINDER

D DEPTH (DEEP)

D DIFFUSER

d PENNY (as in nail - 10d)

D&M DRESSED AND MATCHED

DA DOUBLE ACTING

DB DRY BULB

dB DECIBEL

DBL DOUBLE

DC DIRECT CURRENT

DCJ DOWELED CONTROL

JOINT

DCJT DUMMY CONTROL JOINT

DCL DOOR CLOSER

DCW DOMESTIC COLD WATER

DEG DEGREE

DEMO DEMOLITION

DEPR DEPRESSION

DEPT DEPARTMENT

DET DETAIL

DF DRINKING FOUNTAIN

DH DOUBLE HUNG

DHW DOMESTIC HOT WATER

DI DEIONIZED WATER

DIA DIAMETER

CLO CLOSET

FR FIRE RATED

U/C UNDER CABINET

SYMBOL LEGEND

PLAN VIEW

SECTION / ELEVATION VIEW

SHEAR WALL

MASONRY-CMU

CONCRETE

GRAVEL

EARTH / COMPACTED

EARTH /

NONCOMPACTED

RIGID INSULATION

JOINT FILLER

STEEL

GYPSUM

MASONRY-VENEER

STUD WALL

FLEXIBLE INSULATION

GROUT

PLYWOOD

WOOD (FINISH)

MASONRY-CMU FACE

MASONRY-CMU

MASONRY-VENEER

(402) 493-4800 www.schemmer.com

REVISED TITLE OF SHEET DRAWING NO.

SHEET

PMIS / PKG. NO.

OF

SUB SHEET NO.

ARCH/ENG PROJ #

DESIGNED

DRAWN

CHECKED

PREPARED

DATE

227763 / 80111

177740

C U s e rs \b b e n tz in g e r\ D o c u m e n ts \0

-A

R C

H

R b ill

H

P G

.r v t

PJB

PJB

PJB

01/28/2022

07310.022

A 000

ARCHITECTURAL INFO SHEET

07310022- 2- A 000 ARCHITECTURAL INFO SHEET

REHAB CEDAR PASS COTTAGE

CEDAR PASS LODGE

20681 SD-240, INTERIOR, SD 57750

REF. DEMO NOTES ( )

PROJECT ARCHITECTURAL REFERENCED DEMOLITION NOTES

XDX

PROJECT ARCHITECTURAL REFERENCED NOTES

REF. NOTES ( )

1.02 REMOVE FOUNDATION WALL AND FOOTING.

1.04 REMOVE CONCRETE FLOOR SLAB.

1.06 REMOVE CHIMNEY

1.08 REMOVE WOOD STUD WALL.

1.09 REMOVE MASONRY WALL.

1.10 REMOVE AND REINSTALL PINE WALL PANELING, WALL BASE AND

TRIM. TO BE REINSTALLED IN BEDROOM 2-#107.

1.12 REMOVE GYPSUM WALL BOARD.

1.13 REMOVE FLOOR STRUCTURE, SHEATHING, & FLOOR COVERING

FOR ENTIRE LEVEL.

1.15 REMOVE A PORTION OF WALL FOR NEW OPENING.

1.17 REMOVE DOOR AND FRAME.

1.20 REMOVE AND REINSTALL DOOR, TRIM, AND FRAME. NEW

LOCATION DOOR 108-B

1.25 REMOVE ROOF TRUSSES, ROOF SHEATHING, INSULATION, &

METAL ROOFING

1.26 REMOVE WINDOW.

1.28 REMOVE SMOKE DETECTORS

1.31 REMOVE FURNACE AND DUCTWORK

1.32 REMOVE GYPSUM BOARD CEILING AND FRAMING.

1.35 REMOVE LIGHTING. REFER TO ELECTRICAL.

1.41 REMOVE STAIRS

1.43 REMOVE WATER HEATER AND PIPING. REFER TO MECHANICAL.

1.44 REMOVE PLUMBING FIXTURE. REFER TO MECHANICAL.

1.46 REMOVE BASE CABINET AND COUNTERTOP.

1.47 REMOVE UPPER WALL CABINET.

1.66 REMOVE SHOWER ROD AND CURTAIN.

1.68 REMOVE ALL TOILET ACCESSORIES.

1.99 POSSIBLE PANEL LOCATIONS FOR WALL REMOVAL AND

REINSTALLATION NOTED BY HEAVY LINES.

3.05 EXTERIOR WALL TO BE FILLED WITH NEW SPRAY-ON INSULATION

R-20 MIN, TYPICAL

3.09 EIFS FAUX CHIMNEY BEGINS @ TRUSS BEARING

3.13 24" X 24" LIFT OUT ACCESS PANEL TO CRAWL SPACE. MFR TO

PROVIDE KEY LOCKING SECURITY DEVICE TO PREVENT

UNAUTHORIZED ACCESS. BELOW ACCESS PANEL, IN CRAWL

SPACE, PROVIDE ACCESS LADDER. MOUNT LADDER TO 2X4 WALL

FROM FLOOR JOISTS TO FLOOR OF CRAWL SPACE. ALL WOOD IN

CONTACT WITH CONCRETE FLOOR SHALL BE TREATED.

3.17 NEW 5/8" GWB ON EXTERIOR WALLS, TYP.

3.18 NEW 3/8" PLYWOOD ON EXTERIOR WALLS WITH REINSTALLED PINE

PANELING, WALL BASE, AND TRIM. PINE PANELING TO BE

FURBISHED TO MATCH ORIGINAL FOR CONSISTENT COLOR AND

FINISH.

4.05 30" X 60" ROLL-IN FIBERGLASS SHOWER STALL

4.07 TANK STYLE WATER CLOSET. SEE PLUMBING

4.19 RANGE HOOD, PROVIDE REMOTE ACTIVATION. REFER TO MECH.

FURNISHED BY CONTRACTOR,. INSTALLED BY CONTRACTOR.

4.20 SINK. REFER TO PLUMBING

4.25 WOOD BASE CABINET.

4.28 WOOD WALL CABINET.

4.29 OPEN SHELF WALL CABINET. EXPOSED INTERIOR SURFACE SHALL

BE PLASTIC LAMINATE.

4.35 FINISHED END PANEL - WOOD CABINET

4.37 PLASTIC LAMINATE COUNTERTOP WITH INTEGRAL BACKSPLASH.

SCRIBE TO WALL.

4.38 SOLID SURFACE COUNTERTOP WITH INTEGRAL BACKSPLASH.

SCRIBE TO WALL.

4.43 SOLID SURFACE VANITY COUNTERTOP WITH UNDER-MOUNT SINK.

4.44 SOLID SURFACE VANITY COUNTERTOP WITH INTEGRAL SINK. OPEN

BELOW FOR ABAAS ACCESS

4.50 COUNTERTOP SUPPORT BRACKET.

4.65 REFRIGERATOR FURNISHED BY CONTRACTOR, INSTALLED BY

CONTRACTOR.

4.66 RANGE FURNISHED BY CONTRACTOR, INSTALLED BY CONTRACTOR.

4.68 DISHWASHER FURNISHED BY CONTRACTOR, INSTALLED BY

CONTRACTOR.

4.69 MICROWAVE FURNISHED BY CONTRACTOR, INSTALLED BY

CONTRACTOR.

4.73 REINSTALL EXISTING WOOD BASE. IF UNABLE TO RE-USE, INSTALL

MATCHING MATERIAL IN KIND

4.74 REINSTALL EXISTING WOOD CROWN MOLDING. IF UNABLE TO

RE-USE, INSTALL MATCHING MATERIAL IN KIND

4.80 CLOSET ROD & SHELF

5.03 5/8" GYPSUM BOARD CEILING ATTACHED TO BTTM OF TRUSS

5.21 24" SQ. ATTIC ACCESS PANEL. MFR TO PROVE KEY LOCKING

SECURITY DEVICE.

5.31 EXHAUST FAN, REFER TO MECH

5.34 SURFACE MOUNTED LIGHT FIXTURE. REFER TO ELECTRICAL.

6.06 SYNTHETIC COMPOSITE CEDAR SHAKE ROOFING

6.19 PREFINISHED METAL GUTTER

6.20 PREFINISHED 2" X 3" METAL DOWNSPOUT WITH EXTENSION.

7.06 EXTERIOR FINISH INSULATION SYSTEM (EFIS-1)

7.07 FAUX CHIMNEY - 2X6 FRAMING WITH EIFS FINISH (EFIS-1)

7.14 FIBER-CEMENT TEXTURED 5/4 TRIM BOARD. 8" WIDTH: PAINTED

7.33 MECHANICAL EXHAUST VENT. REFER TO MECHANICAL.

7.34 ELECTRICAL EQUIP. REFER TO ELECTRICAL.

7.36 MECHANICAL SUPPLY VENT. REFER TO MECHANICAL.

7.40 12"X18" THRU-WALL LOUVERED VENT WITH INSECT SCREEN.

CENTER ON GABLE.

8.02 CONCRETE FOUNDATION WALL. REFER TO STRUCTURAL.

8.04 SPRAY-ON INSULATION WITH DEPTH NECESSARY TO ACHIEVE AN

R-VALUE OF 30

8.06 VAPOR BARRIER - VAPOR RETARDER FOR CRAWL SPACES

8.07 WOOD FLOOR JOIST. REFER TO STRUCTURAL.

8.08 WOOD ROOF TRUSS. REFER TO STRUCTURAL.

8.09 CRAWL SPACE DRAINAGE SYSTEM, REFER TO STRUCTURAL.

8.10 WATERPROOFING SYSTEM: SHEET WATERPROOFING MEMBRANE,

2" RIGID INSULATION PROTECTION BOARD, 1/4" DRAINAGE PANEL.

8.12 WD BEAM. REFER TO STRUCTURAL.

8.13 COLUMN. REFER TO STRUCTURAL.

8.14 ADA KNEE & TOE CLEARANCES

UP

WH

1.26 1.26

1.26

1.26

1.26 1.26 1.26

1.26

1.26

1.26

1.26

1.26

1.26

1.26

1.17

1.171.17

1.17

1.17

1.17

1.17

1.17

1.17

1.171.17

1.12

1.12

1.12

1.12

1.12

1.12

1.12

1.12

1.12

1.12

1.12

1.12

1.12

1.12

1.121.12

1.12

1.20

1.12

1.10

1.10 1.10

1.10 1.10

1.10

1.08

1.08

1.08

1.08

1.06

1.44

1.44

1.44

1.44

1.44

1.66

1.68

1.15

1.15

1.15

1.15

1.15

1.15

1.131.13

1.131.13

1.131.13

1.131.13

1.46

1.46

1.46

1.46

1.47

1.47

1.47 1.47

1.47

1.08

1.15

1.41

1.02

1.02

1.02

1.02

1.02

1.02

1.02

1.02

1.02

1.02

1.41

1.041.04

1.09

1.09

1.06

1.31

1.43

1044 North 115th Street | Suite 300

Omaha, NE 68154

(402) 493-4800 www.schemmer.com

REVISED TITLE OF SHEET DRAWING NO.

SHEET

PMIS / PKG. NO.

OF

SUB SHEET NO.

ARCH/ENG PROJ #

DESIGNED

DRAWN

CHECKED

PREPARED

DATE

227763 / 80111

177740

C U s e rs \b b e n tz in g e r\ D o c u m e n ts \0

-A

R C

H

R b ill

H

P G

.r v t

RJM

WEB

PJB

01/28/2022

07310.022

A001

DEMOLITION FLOOR PLANS

07310022- 2- A001 DEMOLITION FLOOR PLANS

REHAB CEDAR PASS COTTAGE

CEDAR PASS LODGE

20681 SD-240, INTERIOR, SD 57750

REF. DEMO NOTES ( ):DX

1.02 REMOVE FOUNDATION WALL AND FOOTING.

1.04 REMOVE CONCRETE FLOOR SLAB.

1.06 REMOVE CHIMNEY

1.08 REMOVE WOOD STUD WALL.

1.09 REMOVE MASONRY WALL.

1.10 REMOVE AND REINSTALL PINE WALL PANELING, WALL BASE AND TRIM. TO

BE REINSTALLED IN BEDROOM 2-#107.

1.12 REMOVE GYPSUM WALL BOARD.

1.13 REMOVE FLOOR STRUCTURE, SHEATHING, & FLOOR COVERING FOR

ENTIRE LEVEL.

1.15 REMOVE A PORTION OF WALL FOR NEW OPENING.

1.17 REMOVE DOOR AND FRAME.

1.20 REMOVE AND REINSTALL DOOR, TRIM, AND FRAME. NEW LOCATION DOOR

108-B

1.26 REMOVE WINDOW.

1.31 REMOVE FURNACE AND DUCTWORK

1.41 REMOVE STAIRS

1.43 REMOVE WATER HEATER AND PIPING. REFER TO MECHANICAL.

1.44 REMOVE PLUMBING FIXTURE. REFER TO MECHANICAL.

1.46 REMOVE BASE CABINET AND COUNTERTOP.

1.47 REMOVE UPPER WALL CABINET.

1.66 REMOVE SHOWER ROD AND CURTAIN.

1.68 REMOVE ALL TOILET ACCESSORIES.

SCALE: 1/4" = 1'-0"

FIRST FLOOR - DEMOLITION

SCALE: 1/4" = 1'-0"

SUB GRADE - DEMOLITION

NORTH

DATE INITIAL

GENERAL NOTES

1. ALL WALLS TO BE REMOVED, PROTECTED, AND STORED ON

SITE, AND REINSTALLED ON NEW FOUNDATION.

2. CONTRACTOR HAS OPTION TO PANELIZE THE WALL

SECTIONS FOR REMOVAL AND REINSTALLATION.

3. NOTIFY CONTRACTING OFFICER OF ANY STUDS OR SILL

PLATES WHICH HAVE DETERIORATED AND ARE DEEMED

UNACCEPTABLE FOR REUSE; REFER TO CONTRACT PRICE

SCHEDULE OPTIONS A AND B IN ORDER TO SUBMIT AND

ACQUIRE CONTRACTING OFFICER'S APPROVAL AND

ACCEPTANCE OF MODIFICATION.

4. SALVAGED WALLS FOR REINSTALLATION ARE TO CONSIST

OF WOOD FRAMING ONLY, AND SHALL BE CLEAN OF

SHEATHING, INTERIOR AND EXTERIOR FINISHES, NAILS,

SCREWS, AND OTHER ITEMS WHICH WOULD INTERFERE WITH

THE INSTALLATION OF NEW SHEATHING, INTERIOR AND

EXTERIOR FINISHES, AND COMPONENTS . SALVAGED WALLS

TO BE LEVEL AND TRUE.

S

1.25

1.25

1.25

1.25

1.25

1.06

1.32

1.32

1.32

1.32

1.32

1.32

1.32 1.32

1.32

1.32

1.35

1.35

1.35 1.35

1.35 1.35

1.35

1.35

1.28

1.28

1.35

1.06

1044 North 115th Street | Suite 300

Omaha, NE 68154

(402) 493-4800 www.schemmer.com

REVISED TITLE OF SHEET DRAWING NO.

SHEET

PMIS / PKG. NO.

OF

SUB SHEET NO.

ARCH/ENG PROJ #

DESIGNED

DRAWN

CHECKED

PREPARED

DATE

227763 / 80111

177740

C U s e rs \b b e n tz in g e r\ D o c u m e n ts \0

-A

R C

H

R b ill

H

P G

.r v t

RJM

Author

WEB

01/28/2022

07310.022

A002

DEMOLITION REFLECTED

CEILING PLAN & ROOF

07310022- 2- A002 DEMOLITION REFLECTED CEILING PLAN & ROOF

REHAB CEDAR PASS COTTAGE

CEDAR PASS LODGE

20681 SD-240, INTERIOR, SD 57750

SCALE: 1/4" = 1'-0"

ROOF PLAN - DEMOLITION

1.06 REMOVE CHIMNEY

1.25 REMOVE ROOF TRUSSES, ROOF SHEATHING, INSULATION, & METAL

ROOFING

1.28 REMOVE SMOKE DETECTORS

1.32 REMOVE GYPSUM BOARD CEILING AND FRAMING.

1.35 REMOVE LIGHTING. REFER TO ELECTRICAL.

REF. DEMO NOTES ( ):DX

SCALE: 1/4" = 1'-0"

FIRST FLOOR - REFLECTED CEILING DEMOLITION

1.06 REMOVE CHIMNEY

1.25 REMOVE ROOF TRUSSES, ROOF SHEATHING, INSULATION, & METAL

ROOFING

1.28 REMOVE SMOKE DETECTORS

1.32 REMOVE GYPSUM BOARD CEILING AND FRAMING.

1.35 REMOVE LIGHTING. REFER TO ELECTRICAL.

NORTH

DATE INITIAL

GENERAL NOTES

1. ALL WALLS TO BE REMOVED, PROTECTED, AND STORED ON

SITE, AND REINSTALLED ON NEW FOUNDATION.

2. CONTRACTOR HAS OPTION TO PANELIZE THE WALL

SECTIONS FOR REMOVAL AND REINSTALLATION.

3. NOTIFY CONTRACTING OFFICER OF ANY STUDS OR SILL

PLATES WHICH HAVE DETERIORATED AND ARE DEEMED

UNACCEPTABLE FOR REUSE; REFER TO CONTRACT PRICE

SCHEDULE OPTIONS A AND B IN ORDER TO SUBMIT AND

ACQUIRE CONTRACTING OFFICER'S APPROVAL AND

ACCEPTANCE OF MODIFICATION.

4. SALVAGED WALLS FOR REINSTALLATION ARE TO CONSIST

OF WOOD FRAMING ONLY, AND SHALL BE CLEAN OF

SHEATHING, INTERIOR AND EXTERIOR FINISHES, NAILS,

SCREWS, AND OTHER ITEMS WHICH WOULD INTERFERE WITH

THE INSTALLATION OF NEW SHEATHING, INTERIOR AND

UP

1.99

Omaha, NE 68154

(402) 493-4800 www.schemmer.com

REVISED TITLE OF SHEET DRAWING NO.

SHEET

PMIS / PKG. NO.

OF

SUB SHEET NO.

ARCH/ENG PROJ #

DESIGNED

DRAWN

CHECKED

PREPARED

DATE

227763 / 80111

177740

C U s e rs \b b e n tz in g e r\ D o c u m e n ts \0

-A

R C

H

R b ill

H

P G

.r v t

WEB

WEB

PJB

01/28/2022

07310.022

A003

DEMOLITION PANEL PLAN

07310022- 2- A003 DEMOLITION PANEL PLAN

REHAB CEDAR PASS COTTAGE

CEDAR PASS LODGE

20681 SD-240, INTERIOR, SD 57750

SCALE: 1/4" = 1'-0"

FIRST FLOOR - DEMOLITION PANELS PLAN

REF. DEMO NOTES ( ):DX

1.99 POSSIBLE PANEL LOCATIONS FOR WALL REMOVAL AND REINSTALLATION

NOTED BY HEAVY LINES.

1.99 POSSIBLE PANEL LOCATIONS FOR WALL REMOVAL AND REINSTALLATION

NOTED BY HEAVY LINES.

NORTH

DATE INITIAL

GENERAL NOTES

1. ALL WALLS TO BE REMOVED, PROTECTED, AND STORED ON

SITE, AND REINSTALLED ON NEW FOUNDATION.

2. CONTRACTOR HAS OPTION TO PANELIZE THE WALL

SECTIONS FOR REMOVAL AND REINSTALLATION.

3. NOTIFY CONTRACTING OFFICER OF ANY STUDS OR SILL

PLATES WHICH HAVE DETERIORATED AND ARE DEEMED

UNACCEPTABLE FOR REUSE; REFER TO CONTRACT PRICE

SCHEDULE OPTIONS A AND B IN ORDER TO SUBMIT AND

ACQUIRE CONTRACTING OFFICER'S APPROVAL AND

ACCEPTANCE OF MODIFICATION.

4. SALVAGED WALLS FOR REINSTALLATION ARE TO CONSIST

OF WOOD FRAMING ONLY, AND SHALL BE CLEAN OF

SHEATHING, INTERIOR AND EXTERIOR FINISHES, NAILS,

SCREWS, AND OTHER ITEMS WHICH WOULD INTERFERE WITH

THE INSTALLATION OF NEW SHEATHING, INTERIOR AND

(402) 493-4800 www.schemmer.com

REVISED TITLE OF SHEET DRAWING NO.

SHEET

PMIS / PKG. NO.

OF

SUB SHEET NO.

ARCH/ENG PROJ #

DESIGNED

DRAWN

CHECKED

PREPARED

DATE

227763 / 80111

177740

C U s e rs \b b e n tz in g e r\ D o c u m e n ts \0

-A

R C

H

R b ill

H

P G

.r v t

WEB

WEB

PJB

01/28/2022

07310.022

A004

DEMOLITION EXISTING

CONDITIONS EXTERIOR

07310022- 2- A004 DEMOLITION EXISTING CONDITIONS EXTERIOR

REHAB CEDAR PASS COTTAGE

CEDAR PASS LODGE

20681 SD-240, INTERIOR, SD 57750

DATE INITIAL

WEST ELEVATION

SITE REPRESENTATIVE PHOTO GALLERY

1. THE FOLLOWING PHOTOGRAPHS DEPICT EXISTING CONDITIONS OF THE HISTORIC COTTAGE FOR CONTRACTOR REFERENCE ONLY AND DOES NOT FULLY PHOTO DOCUMENT THE ENTIRETY OF THE STRUCTURE OR THE PROJECT AREA. BIDDING CONTRACTORS REMAIN RESPONSIBLE FOR FAMILIARIZATION THEMSELVES WITH THE SITE TO THE EXTENT THEY DETERMINE IN ORDER TO PREPARE THEIR BID. THE AWARDED CONTRACTOR SHALL REMAIN RESPONSIBLE FOR TAKING PRE-CONSTRUCTION

PHOTOGRAPHS REQUIRED IN THE SPECIFICATIONS WITHIN THESE DOCUMENTS.

NORTH ELEVATION EAST ELEVATION SOUTH ELEVATION

DAMAGE TO STUCCO & FOUNDATION DAMAGE TO STUCCO & CONDITION OF WINDOWS DAMAGE TO STUCCO AT FOUNDATION

VIEW OF SOFFIT EXISTING WINDOW & STUCCO STANDING SEAM METAL ROOF & CHIMNEY

CONDITION OF EXTERIOR WALLS, FLOOR & STOOP ELECTRICAL SERVICE

(402) 493-4800 www.schemmer.com

REVISED TITLE OF SHEET DRAWING NO.

SHEET

PMIS / PKG. NO.

OF

SUB SHEET NO.

ARCH/ENG PROJ #

DESIGNED

DRAWN

CHECKED

PREPARED

DATE

227763 / 80111

177740

C U s e rs \b b e n tz in g e r\ D o c u m e n ts \0

-A

R C

H

R b ill

H

P G

.r v t

WEB

WEB

PBJ

01/28/2022

07310.022

A005

DEMOLITION EXISTING

CONDITIONS INTERIOR

07310022- 2- A005 DEMOLITION EXISTING CONDITIONS INTERIOR

REHAB CEDAR PASS COTTAGE

CEDAR PASS LODGE

20681 SD-240, INTERIOR, SD 57750

DATE INITIAL

FRONT DOOR & LIVING ROOM LIVING ROOM W/ VIEW TO HALL LIVING ROOM

VIEW TO HALL CABINETS VIEW OF SOUTH WALL KITCHEN & DOOR BEDROOM 2, NORTH &

EAST WALL

BEDROOM 2, WEST & SOUTH WALLS BASEMENT BASEMENT

BEDROOM 1, WEST & NORTH WALLS BEDROOM 1, SOUTH WALL

BATHROOM NORTH WALL BASEMENT STAIRS

SITE REPRESENTATIVE PHOTO GALLERY

1. THE FOLLOWING PHOTOGRAPHS DEPICT EXISTING CONDITIONS OF THE HISTORIC COTTAGE FOR CONTRACTOR REFERENCE ONLY AND DOES NOT FULLY PHOTO DOCUMENT THE ENTIRETY OF THE STRUCTURE OR THE PROJECT AREA. BIDDING CONTRACTORS REMAIN RESPONSIBLE FOR FAMILIARIZATION THEMSELVES WITH THE SITE TO THE EXTENT THEY DETERMINE IN ORDER TO PREPARE THEIR BID. THE AWARDED CONTRACTOR SHALL REMAIN RESPONSIBLE FOR TAKING PRE-CONSTRUCTION

PHOTOGRAPHS REQUIRED IN THE SPECIFICATIONS WITHIN THESE DOCUMENTS.

THE OWNER WILL REMOVE

ALL DEBRIS PRIOR TO THE

CONTRACTOR'S NOTICE TO

PROCEED, TYP.

THE OWNER WILL REMOVE

ALL DEBRIS PRIOR TO THE

CONTRACTOR'S NOTICE TO

PROCEED, TYP.

THE OWNER WILL REMOVE

ALL DEBRIS PRIOR TO THE

CONTRACTOR'S NOTICE TO

PROCEED, TYP.

PINE PANELING, WALL BASE,AND

TRIM TO BE SALVAGED FOR

REINSTALLATION.

THE OWNER WILL REMOVE

ALL DEBRIS PRIOR TO THE

CONTRACTOR'S NOTICE TO

PROCEED, TYP.

THE OWNER WILL REMOVE

ALL DEBRIS PRIOR TO THE

CONTRACTOR'S NOTICE TO

PROCEED, TYP.

-B

REF.

-A

100-C

104-B

-B

100-A

-B

DW

108-A 1

-B

F E

B

LIVING

CLST

BEDROOM 1

CLST

HALL

CLST

BATH

BEDROOM 2

UTIL

108 ENTRY

CLST

KITCHEN

11 5/8"

2'-0 3/4"

/4

3'-4 7/8" 3'-6 7/8"

/4

AA

C

B

C

C C

D

B

A501

A501

A202

A202

W5 W1

W4

2'-10 3/4" 1'-6"

/8

W6

B

4.05

4.44

4.38

A202

A401

4.69

3.13

3.09

W7

W3

W7

W7 W2

W5

W6

4.80

4.80

4.80

3.183.18

3.17

3.173.17

3.17

3.17

3.173.17

3.173.17

3.17

W7

W4

W1

W3

W8

W8

2'-5" 6'-10 7/8" 3'-5 1/2" 5'-5 1/4"

/8

/2

2'-11" 3'-5 3/8"1'-8" 2'-5" 3'-2" 3'-1 1/2"

9" 3'-10"

/2

9" 3'-10"

/2

/4

1'-7 1/4" 3'-3 1/8"

/4

A501

A401

E

E E

3.18

2'-6"

A

A F

4.80

E

4'-0"

E

3.05

3.05

3.05

3.05

3.05

3.05

3.05

3.05

3.05

3.05

A401

6 1/2" / 12"6 1/2" / 12"

6 1/2" / 12"

PREFIN MET GUTTER -

5" K STYLE

SYNTHETIC COMPOSITE CEDAR

SHAKE ROOFING. ICE AND WATER

SHIELD UNDER ENTIRE ROOF

PREFIN MET GUTTER -

5" K STYLE

PREFIN MET GUTTER -

5" K STYLE

FAUX CHIMNEY

LINE OF EXTERIOR

FACE OF WALL BELOW

PREFIN MET GUTTER -

5" K STYLE

SYNTHETIC COMPOSITE CEDAR

SHAKE ROOFING. ICE AND WATER

SHIELD UNDER ENTIRE ROOF

CRICKET

1044 North 115th Street | Suite 300

Omaha, NE 68154

(402) 493-4800 www.schemmer.com

REVISED TITLE OF SHEET DRAWING NO.

SHEET

PMIS / PKG. NO.

OF

SUB SHEET NO.

ARCH/ENG PROJ #

DESIGNED

DRAWN

CHECKED

PREPARED

DATE

227763 / 80111

177740

C U s e rs \b b e n tz in g e r\ D o c u m e n ts \0

-A

R C

H

R b ill

H

P G

.r v t

RJM

WEB

PJB

01/28/2022

07310.022

A101

FLOOR PLAN, ROOF PLAN

07310022- 2- A101 FLOOR PLAN, ROOF PLAN

REHAB CEDAR PASS COTTAGE

CEDAR PASS LODGE

20681 SD-240, INTERIOR, SD 57750

REF. NOTES ( ):X

PARTITION TYPES ( ):X

TYPE WIDTH

A 0' - 4 1/8" 2X4 WD STUD @ 16" OC W/ 5/8" GWB ONE SIDE TO STRUCTURE

ABOVE

B 0' - 4 3/4" 2X4 WD STUD @ 16" OC W/ 5/8" GWB EACH SIDE TO

STRUCTURE ABOVE

C 0' - 4 1/2" 2X4 WD STUD @ 16" OC W/ 5/8" GWB ONE SIDE - 3/8" PLYWOOD

ONE SIDE TO STRUCTURE ABOVE

D 0' - 4 1/4" 2X4 WD STUD @ 16" OC W/ 3/8"" PLWD EACH SIDE TO

STRUCTURE ABOVE

E 0' - 0 3/4" REINSTALLED PINE WALL PANELING

F 0' - 3 7/8" 2X4 WD STUD @ 16" OC W/ 3/8" PLWD ONE SIDE TO

STRUCTURE ABOVE

TOILET ACCESSORIES ( ):TA-X

NUMBER DESCRIPTION

TA-1 VERTICAL 18" GRAB BAR

TA-2 HORIZONTAL 42" GRAB BAR

TA-3 HORIZONTAL 36" GRAB BAR

TA-12 SINGLE TOLET PAPER ROLL HOLDER

TA-25 FACIAL TISSUE DISPENSER - RECESSED

TA-28 SINGLE ROBE HOOK

TA-30 TOWEL RING

TA-37 2'-6" X 1'-4" MIRROR

SCALE: 1/4" = 1'-0"

FLOOR PLAN

NORTH

SCALE: 1/4" = 1'-0"

ROOF PLAN

NORTH

DATE INITIAL

3.05 EXTERIOR WALL TO BE FILLED WITH NEW SPRAY-ON INSULATION R-20

MIN, TYPICAL

3.09 EIFS FAUX CHIMNEY BEGINS @ TRUSS BEARING

3.13 24" X 24" LIFT OUT ACCESS PANEL TO CRAWL SPACE. MFR TO PROVIDE

KEY LOCKING SECURITY DEVICE TO PREVENT UNAUTHORIZED ACCESS.

BELOW ACCESS PANEL, IN CRAWL SPACE, PROVIDE ACCESS LADDER.

MOUNT LADDER TO 2X4 WALL FROM FLOOR JOISTS TO FLOOR OF CRAWL

SPACE. ALL WOOD IN CONTACT WITH CONCRETE FLOOR SHALL BE

TREATED.

3.17 NEW 5/8" GWB ON EXTERIOR WALLS, TYP.

3.18 NEW 3/8" PLYWOOD ON EXTERIOR WALLS WITH REINSTALLED PINE

PANELING, WALL BASE, AND TRIM. PINE PANELING TO BE FURBISHED TO

MATCH ORIGINAL FOR CONSISTENT COLOR AND FINISH.

4.05 30" X 60" ROLL-IN FIBERGLASS SHOWER STALL

4.38 SOLID SURFACE COUNTERTOP WITH INTEGRAL BACKSPLASH. SCRIBE TO

WALL.

4.44 SOLID SURFACE VANITY COUNTERTOP WITH INTEGRAL SINK. OPEN

BELOW FOR ABAAS ACCESS

4.69 MICROWAVE FURNISHED BY CONTRACTOR, INSTALLED BY CONTRACTOR.

4.80 CLOSET ROD & SHELF

GENERAL NOTES

1. CONTRACTOR SHALL VERIFY WINDOW ROUGH OPENING

DIMENSIONS PER WINDOW SIZES AND PER MANUFACTURER

RECOMMENDATIONS.

ATTIC VENTILATION CALCULATIONS

ROOF AREA: 1,667 SF

RATIO: 1/300

REQUIRED: 400 SQ IN / INTAKE

400 SQ IN / EXHAUST

4 VENTS 18X12: 864 SQ IN

FIRST FLOOR

100' - 0"

T.O.,WALL

108' - 1 1/8"

A202

4"

12"

6"

12"

A202 6.06

7.07

7.14

6.19

6.20

7.06

7.14

6.19

6.20

7.40

A401

/8

7.33

FIRST FLOOR

100' - 0"

T.O.,WALL

108' - 1 1/8"

A202

6 1/2"

12"

A401 6.06

7.14

6.19

6.20

7.06

6.06

6.19

6.20

7.40

A401

FIRST FLOOR

100' - 0"

T.O.,WALL

108' - 1 1/8"

A202

A202 6.06

6.19

6.20

7.06

7.07

6.19

6.20

7.14 5.34

4"

12"

7.40

A401

/4

7.36

FIRST FLOOR

100' - 0"

T.O.,WALL

108' - 1 1/8"

A202

6 1/2"

12"

A401 6.06

6.19

7.06

6.20

7.34

6.06

7.14

6.19

7.06

6.20

7.40

A401

1044 North 115th Street | Suite 300

Omaha, NE 68154

(402) 493-4800 www.schemmer.com

REVISED TITLE OF SHEET DRAWING NO.

SHEET

PMIS / PKG. NO.

OF

SUB SHEET NO.

ARCH/ENG PROJ #

DESIGNED

DRAWN

CHECKED

PREPARED

DATE

227763 / 80111

177740

C U s e rs \b b e n tz in g e r\ D o c u m e n ts \0

-A

R C

H

R b ill

H

P G

.r v t

RJM

WEB

PJB

01/28/2022

07310.022

A201

EXTERIOR BUILDING

ELEVATIONS

07310022- 2- A201 EXTERIOR BUILDING ELEVATIONS

REHAB CEDAR PASS COTTAGE

CEDAR PASS LODGE

20681 SD-240, INTERIOR, SD 57750

SCALE: 1/4" = 1'-0"

WEST ELEVATION

SCALE: 1/4" = 1'-0"

NORTH ELEVATION

SCALE: 1/4" = 1'-0"

EAST ELEVATION

SCALE: 1/4" = 1'-0"

SOUTH ELEVATION

7.34 ELECTRICAL EQUIP. REFER TO ELECTRICAL.

7.36 MECHANICAL SUPPLY VENT. REFER TO MECHANICAL.

7.40 12"X18" THRU-WALL LOUVERED VENT WITH INSECT SCREEN. CENTER ON

GABLE.

5.34 SURFACE MOUNTED LIGHT FIXTURE. REFER TO ELECTRICAL.

6.06 SYNTHETIC COMPOSITE CEDAR SHAKE ROOFING

6.19 PREFINISHED METAL GUTTER

6.20 PREFINISHED 2" X 3" METAL DOWNSPOUT WITH EXTENSION.

7.06 EXTERIOR FINISH INSULATION SYSTEM (EFIS-1)

7.07 FAUX CHIMNEY - 2X6 FRAMING WITH EIFS FINISH (EFIS-1)

7.14 FIBER-CEMENT TEXTURED 5/4 TRIM BOARD. 8" WIDTH: PAINTED

7.33 MECHANICAL EXHAUST VENT. REFER TO MECHANICAL.

REF. NOTES ( ):X

T.O.,WALL

108' - 1 1/8"

6 1/2"

12"

LIVING

6.06

6.19

7.06

8.02

8.07

8.04

8.068.06 8.06

8.09

A302

A302

8.10

5.03

FIRST FLOOR

100' - 0"

T.O.,WALL

108' - 1 1/8"

4"

12"

A202

A401

BEDROOM 2

CLST

KITCHEN

6.06

6.19

6.20

7.06

8.04 8.02

8.02

8.14

8.068.06 8.06

8.09

8.108.10

5.03

FIRST FLOOR

100' - 0"

T.O.,WALL

108' - 1 1/8"

A202

LIVING

HALL

BEDROOM 2

8.08

7.06

8.078.04

8.13

8.02

6.06

6.19

7.06

8.06

E X

IS

T

IN

G

S O

F F

IT

8.09

8.12

8.13

8.10

8.10

5.03

1044 North 115th Street | Suite 300

Omaha, NE 68154

(402) 493-4800 www.schemmer.com

REVISED TITLE OF SHEET DRAWING NO.

SHEET

PMIS / PKG. NO.

OF

SUB SHEET NO.

ARCH/ENG PROJ #

DESIGNED

DRAWN

CHECKED

PREPARED

DATE

227763 / 80111

177740

C U s e rs \b b e n tz in g e r\ D o c u m e n ts \0

-A

R C

H

R b ill

H

P G

.r v t

RJM

WEB

PJB

01/28/2022

07310.022

A202

BUILDING SECTIONS

07310022- 2- A202 BUILDING SECTIONS

REHAB CEDAR PASS COTTAGE

CEDAR PASS LODGE

20681 SD-240, INTERIOR, SD 57750

SCALE: 1/4" = 1'-0"

BUILDING SECTION

SCALE: 1/4" = 1'-0"

BUILDING SECTION

SCALE: 1/4" = 1'-0"

BUILDING SECTION

5.03 5/8" GYPSUM BOARD CEILING ATTACHED TO BTTM OF TRUSS

6.06 SYNTHETIC COMPOSITE CEDAR SHAKE ROOFING

6.19 PREFINISHED METAL GUTTER

6.20 PREFINISHED 2" X 3" METAL DOWNSPOUT WITH EXTENSION.

7.06 EXTERIOR FINISH INSULATION SYSTEM (EFIS-1)

8.02 CONCRETE FOUNDATION WALL. REFER TO STRUCTURAL.

8.04 SPRAY-ON INSULATION WITH DEPTH NECESSARY TO ACHIEVE AN

R-VALUE OF 30

8.06 VAPOR BARRIER - VAPOR RETARDER FOR CRAWL SPACES

8.07 WOOD FLOOR JOIST. REFER TO STRUCTURAL.

8.08 WOOD ROOF TRUSS. REFER TO STRUCTURAL.

8.09 CRAWL SPACE DRAINAGE SYSTEM, REFER TO STRUCTURAL.

8.10 WATERPROOFING SYSTEM: SHEET WATERPROOFING MEMBRANE, 2" RIGID

INSULATION PROTECTION BOARD, 1/4" DRAINAGE PANEL.

8.12 WD BEAM. REFER TO STRUCTURAL.

8.13 COLUMN. REFER TO STRUCTURAL.

8.14 ADA KNEE & TOE CLEARANCES

REF. NOTES ( ):X

SEE SCHEDULE

WD : F

S E

E S

C H

E D

U L E

WD : VP

RELOCATED

SEE SCHEDULE

WD : FL

S E

E S

C H

E D

U L E

SEE SCHEDULE

S E

E S

C H

E D

U L E

24"

NEW WD

LOUVERS

PREFIN

MET

LOUVERS

SEE SCHEDULE

FG : FV3

S E

E S

C H

E D

U L E

REEDED

TEXTURED

GLASS - IG-2

WD : F1

2"

SEE SCHEDULE

2"

S E

E S

C H

E D

U L E

W1

WD

W3

WD

W4

WD

EGRESS

W5

WD

W6

WD

W2

WD

1'-9"

1'-11"

/4

2'-10 1/2"

/4

2'-1"

/4

2'-5"

/4

2'-11"

W7

WD

/4

3'-10"

W8

WD

/8

2'-7 1/2"

IG-1 IG-1 IG-1 IG-1 IG-1 IG-1 IG-1 IG-1

1044 North 115th Street | Suite 300

Omaha, NE 68154

(402) 493-4800 www.schemmer.com

REVISED TITLE OF SHEET DRAWING NO.

SHEET

PMIS / PKG. NO.

OF

SUB SHEET NO.

ARCH/ENG PROJ #

DESIGNED

DRAWN

CHECKED

PREPARED

DATE

227763 / 80111

177740

C U s e rs \b b e n tz in g e r\ D o c u m e n ts \0

-A

R C

H

R b ill

H

P G

.r v t

RJM

WEB

PBJ

01/28/2022

07310.022

A301

SCHEDULES, DOOR AND

WINDOW DETAILS

07310022- 2- A301 SCHEDULES, DOOR AND WINDOW DETAILS

REHAB CEDAR PASS COTTAGE

CEDAR PASS LODGE

20681 SD-240, INTERIOR, SD 57750

SCALE: 1/4" = 1'-0"

DOOR PANEL TYPES - WOOD (WD) & FIBERGLASS (FG)

SCALE: 1/4" = 1'-0"

DOOR FRAMEW TYPES (WD)

DOOR SCHEDULE

DOOR NO.

DOOR SIZE DOOR FRAME DETAIL

SET TYPE LABEL REMARKSWIDTH HEIGHT MATL & TYPE FINISH GLASS MATL & TYPE FINISH HEAD JAMB JAMB SILL

100-A 3' - 0" 6' - 8" FG : FV3 PAINT IG-2 WD : F1 PAINT 4/A302 5/A302 5/A302 6/A302 ENTRANCE

100-B 3' - 0" 6' - 8" WD : F STAIN - - WD : F1 STAIN 1/A302 2/A302 2/A302 PASSAGE

100-B 2' - 4" 6' - 8" WD : F STAIN - - WD : F1 STAIN 1/A302 2/A302 2/A302 PASSAGE

100-C 2' - 6" 6' - 8" WD : VP - - - - WD : F1 - - 1/A302 2/A302 2/A302 PRIVACY RELOCATED KNOTTY PINE DOOR - SALVAGE & REUSE TRIM.

REFINISH FOR A CONSISTENT COLOR AND FINISH WITH

EXISTING REINSTALLED KNOTTY PINE PANELING. REPLACE

EXISTING METAL LOUVER WITH WOOD LOUVERS TO MATCH

EXISTING WOOD.

102-B PR 2' - 0" 6' - 8" WD : F STAIN - - WD : F1 STAIN 1/A302 2/A302 2/A302 PASSAGE

104-A 3' - 0" 6' - 8" WD : F STAIN - - WD : F1 STAIN 1/A302 2/A302 2/A302 PRIVACY

104-B 3' - 0" 6' - 8" WD : FL STAIN - - WD : F1 STAIN 1/A302 2/A302 2/A302 STOREROOM

108-A 3' - 0" 6' - 8" WD : F STAIN - - WD : F1 STAIN 1/A302 2/A302 2/A302 PRIVACY UNDERCUT DOOR 3/4" FOR RETURN AIR

108-B 3' - 0" 6' - 8" WD : F STAIN - - WD : F1 STAIN 1/A302 2/A302 2/A302 PASSAGE

109 3' - 0" 6' - 8" FG : FV3 PAINT IG-2 WD : F1 PAINT 4/A302 5/A302 5/A302 6/A302 ENTRANCE

111 3' - 0" 6' - 8" FG : FV3 PAINT IG-2 WD : F1 PAINT 4/A302 5/A302 5/A302 6/A302 ENTRANCE

SCALE: 1/4" = 1'-0"

WINDOW TYPES

DATE INITIAL

GLASS TYPES

IG-1 1" INSULATED, CLEAR LOW-E GLASS

IG-2 1" INSULATED. CLEAR LOW-E, TEMPERED GLASS

5/8" GWB BOTH

SIDES ON WOOD

STUDS

2x WOOD

HEADER

WD DOOR

FRAME DOOR, SEE

SCHED

1x HARDWOOD TRIM

BOTH SIDES,

SEE 3/A302

5/8" GWB BOTH

SIDES ON WOOD

STUDS

2x WOOD

STUDS

WD DOOR

FRAME

DOOR, SEE

SCHED

1x HARDWOOD TRIM

BOTH SIDES,

SEE 3/A302

9/16"

/4

SECONDARY BARRIER

DRAINAGE MEDIUM

2" EIFS SYSTEM

/2

FLASHING

2 1/2" WOOD CASING

EIFS COMPATIBLE SEALANT

W/ CLOSED CELL BACKER

ROD PROVIDE WEEP 2' O.C.

WOOD

CASING

SECONDARY BARRIER

DRAINAGE MEDIUM

2" EIFS SYSTEM

2 1/2" WOOD CASING

EIFS COMPATIBLE SEALANT

W/ CLOSED CELL BACKER

ROD

1/2"

WOOD CASING

EXTERIOR WOOD DOOR - SEE

SCHED

AL THRESHOLD SET IN SEALANT-

THRESHOLD SHALL MEET ABAAS.

REFER TO HARDWARE SCHED.

CONC STOOP - REFER TO

STRUCT

PLWD

SHTG

WOOD

FLOORING

/4

/4

/2

SECONDARY BARRIER

DRAINAGE MEDIUM

2" EIFS SYSTEM

FLASHING

EIFS COMPATIBLE SEALANT W/

CLOSED CELL BACKER ROD.

PROVIDE WEEP 2' O.C.

WINDOW - SEE SCHED

WOOD

CASING

MEMBRANE FLASHING

W O

O D

R .O

C O

O R

D W

R

E Q

U

IR

E M

E N

T S

P E

R

W D

W M

A N

U F

WINDOW SEE SCHED

EIFS COMPATIBLE SEALANT W/ CLOSED

CELL BACKER ROD

2" EIFS SYSTEM

MEMBRANE FLASHING

DRAINAGE MEDIUM

SECONDARY BARRIER

WOOD CASING

1/2"

WOOD R.O.

COORD W/ REQUIREMENTS

PER WDW MANUF

/2

WINDOW SEE SCHED

MEMBRANE FLASHING

EIFS COMPATIBLE SEALANT W/

CLOSED CELL BACKER ROD

SECONDARY BARRIER

DRAINAGE MEDIUM

2" EIFS SYSTEM

WOOD

CASING

W O

O D

R .O

C O

O R

D W

IT

H

R E

Q U

IR

E

M E

N T

P E

R W

D W

M A

N U

F

2"

/2

/2

THIS SECTION OF EIFS TO BE

PAINTED P-6

1044 North 115th Street | Suite 300

Omaha, NE 68154

(402) 493-4800 www.schemmer.com

REVISED TITLE OF SHEET DRAWING NO.

SHEET

PMIS / PKG. NO.

OF

SUB SHEET NO.

ARCH/ENG PROJ #

DESIGNED

DRAWN

CHECKED

PREPARED

DATE

227763 / 80111

177740

C U s e rs \b b e n tz in g e r\ D o c u m e n ts \0

-A

R C

H

R b ill

H

P G

.r v t

RJM

WEB

PJB

01/28/2022

07310.022

A302

DOOR & WINDOW DETAILS

07310022- 2- A302 DOOR & WINDOW DETAILS

REHAB CEDAR PASS COTTAGE

CEDAR PASS LODGE

20681 SD-240, INTERIOR, SD 57750

SCALE: 1 1/2" = 1'-0"

INTERIOR DOOR HEAD DETAIL

SCALE: 1 1/2" = 1'-0"

INTERIOR DOOR JAMB DETAIL

SCALE: 3" = 1'-0"

DOOR TRIM

DATE INITIAL

SCALE: 3" = 1'-0"

EXTERIOR DOOR HEAD DETAIL

SCALE: 3" = 1'-0"

EXTERIOR DOOR JAMB DETAIL

SCALE: 3" = 1'-0"

EXTERIOR DOOR SILL DETAIL

SCALE: 3" = 1'-0"

WOOD WINDOW HEAD DETAIL

SCALE: 3" = 1'-0"

WOOD WINDOW JAMB DETAIL

SCALE: 3" = 1'-0"

WOOD WINDOW SILL DETAIL

-B

REF.

-A

100-C

104-B

-B

100-A

-B

DW

108-A 1

-B

F E

B

LIVING

CLST

BEDROOM 1

CLST

HALL

CLST

BATH

106 BEDROOM 2

UTIL

108 ENTRY

CLST

KITCHEN

A

W D

L V

T

L V

T W

D

ADD 1/4" PLWD

BENEATH LVT