Approved for Construction_25-008 SUNRAY CREST KITCHEN_20251010.pdf

PDF 4 MB Posted

Attached to
Sunray Crest IRA - Kitchen Renovation
Solicitation number
2134741
Issued by
Oneida County, New York

About this file

This is an approved construction document for a Kitchen Renovation project at Sunray Crest IRA, located at 6469 Sunray Crest Dr, Victor, NY 14564, prepared by the Finger Lakes Developmental Disability Services Office (DDSO), an agency under the New York Office for People with Developmental Disabilities (OPWDD). The project involves a complete kitchen renovation at the residential facility. A mandatory site visit is required for all prospective bidders on Tuesday, May 19, 2026, at 10:00 a.m. to verify knowledge of the project scope and area. Bids will not be accepted from vendors who do not attend the site visit or arrive late. Prospective bidders must request an invitation for bid by referencing the project title and location on company letterhead, including contact information, and submitting the request via fax to 585-461-8811 (Attention: Franchesca Sagen) or email to FL.Purchasing@opwdd.ny.gov.

This is a New York State public works project requiring the payment of prevailing wages. All bidders must provide a valid New York State Department of Labor (NYSDOL) registration number and submit a Certificate of Registration at the time of bid submission; failure to provide these documents will result in automatic disqualification. Contractors and subcontractors are advised to register promptly with NYSDOL, as the registration review and certificate issuance process typically requires approximately three to four weeks. No advance notification is required to attend the mandatory site visit.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

BUILDING DATADRAWING INDEX

CONSTRUCTION TYPE: TYPE 5B

OCCUPANCY CLASSIFICATION: RESIDENTIAL GROUP R-3

NUMBER OF STORIES: ONE

PROJECT WORK AREA: 258 +/- SF

SPRINKLER SYSTEM: EXISTING

CODE COMPLIANCE: NYS 2020 RESIDENTIAL CODE

NFPA 101 LIFE SAFETY CODE

CHAPTER 33 - EXISTING

BOARD & CARE OCCUPANCIES

ARCHITECTURAL

COVER SHEET CS-101

TYPICAL DETAILS & PARTITION TYPES A-001

FLOOR PLANS & CEILING PLANS A-101

INTERIOR ELEVATIONS & DETAILS A-601

SPECIFICATIONS SP-101

KITCHEN REMODEL PROJECT

6469 SUNRAY CREST DR

VICTOR, NY 14564

HOSTEL #2470

703 EAST MAPLE AVE, BUILDING 70

NEWARK, NEW YORK 14513

4245 UNION ROAD, SUITE 210

BUFFALO, NEW YORK 14225

P:716.923.0133

WWW.ZAXISPC.COM

SITE LOCATION MAP

PROJECT SITE

DRAWING No.

PROJECT No: 25-008

DATE: 6/20/2025

R

EV

IS

IO

N S

D

AT

E N o.-

CS-101

IS

SU

ED

F

O R

R

EV

IE

W 8/

/2

ZA

XI

S

AR

C H

IT

EC

TU

R

AL

P

.C

TH

IS

D O

C U

M

EN

T, A

N D

T H

E

ID

EA

S

AN

D

D

ES

IG

N

S

IN

C O

R

PO

R

AT

ED

H

ER

EI

N , A

R E

TH

E

PR

O

PE

R

TY

O

F

ZA

XI

S

AR

C

H

IT

EC

TU

R

AL

P .C

U N

AU

TH

O R

IZ

ED

R

EP

R O

D U

C

TI

O N

, A

LT

ER

AT

IO

N

O R

A D

D

IT

IO

N

T O

A N

Y D

R

AW

IN

G

D

ES

IG

N , S

PE

C

IF

IC

AT

IO

N , P

LA

N

O R

R

EP

O R

T

IN

W H

O

LE

O R

IN

P

AR

T

W

IT

H O

U T

TH

E

EX

PR

ES

S

W R

IT

TE

N A

U

TH

O R

IZ

AT

IO

N

O F

ZA

XI

S

AR

C H

IT

EC

TU

R

AL

P

.C . I

S

PR

O H

IB

IT

ED

B

Y

SE

C

TI

O N

9, P

R O

VI

SI

O N

O

F

TH

E N

EW

Y

O R

K

ST

AT

E

ED

U

C

AT

IO

N

L

AW

BA

TH

R O

O M

R

EM

O D

EL

P

R O

JE

C

T

N

YS

O

FF

IC

E

FO

R

P

EO

PL

E

W

IT

H D

IS

AB

IL

IT

IE

S

S U

N R

AY

C

R

ES

T D

R , V

IC

TO

R , N

Y

IS

SU

ED

F O

R P

ER

M

IT

B

ID

9/ 5/

R

EI

SS

U

ED

F O

R P

ER

M

IT

B

ID

/7

/2

CAPITAL SERVICES

ACCEPTED FOR CONSTRUCTION

By: stroudjj 10/10/2025Date:

A/C AIR CONDITIONING

ABV ABOVE

ACT ACOUSTICAL CEILING TILE

AD ACCESS DOOR

ADJ ADJACENT

AFF ABOVE FINISHED FLOOR

AHU AIR HANDLING UNIT

ALUM ALUMINUM

ALT ALTERNATE

ANOD ANODIZED

APPROX APPROXIMATE

ARCH ARCHITECT

B WALL BASE

BC BOTTOM OF CURB

BD/BRD BOARD

BLDG BUILDING

BL WINDOW BLINDS

BLK BLOCK

BLKG BLOCKING

BITUM BITUMINOUS

BM BEAM

BOT BOTTOM

BRG BEARING

BRK BRICK

BSMT BASEMENT

BTWN BETWEEN

BW BOTH WAYS

℄ CENTER LINE

CB CATCH BASIN

CF CUBIC FOOT

CG CORNER GUARD

CJ CONTROL JOINT

CLG CEILING

CLOS CLOSET

CLR CLEAR

CMP CORRIGATED METAL PIPE

CMU CONCRETE MASONRY UNIT

CO CLEAN OUT

COL COLUMN

CONC CONCRETE

CONST CONSTRUCTION

CONT CONTINUOUS

CORR CORRIDOR

CPT CARPET

CR CHAIR RAIL

CRS COURSES

CT CERAMIC TILE

CY CUBIC YARD

DBL DOUBLE

DEPT DEPARTMENT

DEMO DEMOLITION

DET DETAIL

DIA DIAMETER

DIAG DIAGIONAL

DIM DIMENSION

DF DRINKING FOUNTAIN

DH DOUBLE HUNG

DI DROP INLET

DN DOWN

DR DOOR

DS DOWN SPOUT

DW DISH WASHER

DWG DRAWING

EA EACH

EF EXHAUST FAN / EACH FACE

EIFS EXTERIOR INSUL & FINISH SYSTEM

EJ EXPANSION JOINT

ELEC ELECTRIC (AL)

ELEV ELEVATOR

EL ELEVATION

ENCL ENCLOSURE

EQ EQUAL

EQUIP EQUIPMENT

EW EACH WAY

EWC ELECTRIC WATER COOLER

EXH EXHAUST

EXIST EXISTING

EXP EXPANSION

EXT EXTERIOR

FA FIRE ALARM

FAI FRESH AIR INTAKE

FD FLOOR DRAIN

FDN FOUNDATION

FE FIRE EXTINGUISHER

FEC FIRE EXTINGUISHER & CABINET

FIN FINISH

FL FLOOR

FT FLOOR TILE

FTG FOOTING

FURR FURRING

G GAS

GA GAUGE

GAL GALLON

GALV GALVANIZED

GB GRAB BAR

GC GENERAL CONTRACTOR

GL GLASS

GWB GYPSUM WALL BOARD

GYP GYPSUM

HB HOSE BIB

H/C HANDICAPPED

HDWD HARDWOOD

HDWR HARDWARE

HM HOLLOW METAL

HORIZ HORIZONTAL

HP HIGH POINT

HR HOUR

HT HEIGHT

HTG HEATING

HVAC HEATING, VENTILATING &

AIR CONDITIONING

HYD HYDRANT

ID INSIDE DIAMETER

INCL INCLUDED

INSUL INSULATION

INT INTERIOR

INV INVERT

JAN JANITOR

JST JOIST

JT JOINT

KIT KITCHEN

LAB LABORATORY

LAM LAMINATED

LAV LAVITORY

LB POUND

LF LINEAL FOOT

LIN LINEAR

LL LIVE LOAD

LLH LONG LEG HORIZONTAL

LLV LONG LEG VERTICAL

LP LOW POINT

MAS MASONRY

MATL MATERIAL

MAX MAXIMUM

MECH MECHANICAL

MEMB MEMBRANE

MFGR MANUFACTURER

MH MAN HOLE

MIN MINIMUM

MISC MISCELLANOUS

MO MASONRY OPENING

MTL METAL

MUL MULLION

N NORTH

N/A NOT APPLICABLE

NIC NOT IN CONTRACT

NOM NOMINAL

NRC NOISE REDUCTION COEFFICIENT

NTS NOT TO SCALE

OC ON CENTER

OD OUTSIDE DIAMETER

OPNG OPENING

OPP OPPOSITE

OV HD OVER HEAD

PERF PERFORATED

PL PLATE / PROPERTY LINE

PLAM PLASTIC LAMINATE

PLAS PLASTER

PLYWD PLYWOOD

P/P POWER PANEL

PR PAIR

PSF POUNDS PER SQUARE FOOT

PSI POUNDS PER SQUARE INCH

PT PRESSURE TREATED /

PORCELAIN TILE

PTD PAINT

PVC POLYVINYL CHLORIDE

PVMT PAVEMENT

QT QUARRY TILE

QTY QUANTITY

R RADIUS / THERMAL RESISTANCE

/ RISER

RCP REFLECTED CEILING PLAN

RD ROOF DRAIN

RDL ROOF DRAIN LEADER

REF REFERENCE

REFR REFRIGERATOR

REINF REINFORCING

REQD REQUIRED

RM ROOM

RO ROUGH OPENING

ROW RIGHT OF WAY

RTU ROOF TOP UNIT

RUB RUBBER

RWC RAIN WATER CONDUCTOR

RWL RAIN WATER LEADER

SAN SANITARY

SCHED SCHEDULE

SECT SECTION

SF SQUARE FOOT

SGFT STRUCTURAL GLAZED FACING TILE

SHR SHOWER

SHT SHEET

SIM SIMILAR

SPEC SPECIFICATIONS

SS STAINLESS STEEL

ST STORM DRAIN TILE

STC SOUND TRANSMISSION CLASS

STD STANDARD

STL STEEL

STOR STORAGE

STRUCT STRUCTURAL

SUSP SUSPENDED

SV SHEET VINYL

SW SWITCH

SYST SYSTEM

T TREAD

T & B TOP AND BOTTOM

TC TOP OF CURB

T & G TOUNGE & GROUVE

TEMP TEMPORARY

TH THRESHOLD

THK THICKNESS

TOM TOP OF MASONRY

TOS TOP OF STEEL

TYP TYPICAL

UNFIN UNFINISHED

UNO UNLESS NOTED OTHERWISE

UR URINAL

VCT VINYL COMPOSITE TILE

VERT VERTICAL

VEST VESTIBULE

VIF VERIFY IN FIELD

VL VISION LITE

VT VINYL TILE

VTR VENT THROUGH ROOF

VWC VINYL WALL COVERING

W/ WITH

W/O WITH OUT

WC WALL COVERING

WD WOOD

WDO WINDOW

WT WALL TILE

WWF WELDED WIRE FABRIC

ROOM NUMBER

IDENTIFICATION

LETTER

PARTIAL SECTIONS OR DETAILS

IDENTIFICATION

DOOR / WINDOW NUMBER

BUILDING SECTION

X

ELEVATION TARGET

AREA TO BE DETAILEDIDENTIFICATION

PLAN DETAIL

NORTH ARROW

SHEET DETAILED ON

OR LETTER

DRAWING NUMBER

SECTION NUMBER

2PARTITION TYPES

BUILDING SECTION

SHEET DETAILED ON

SHEET DETAILED ON

X X-X

X X-X

X X-X

X X-X

SHEET DETAILED ON

SECTION NUMBER

IDENTIFICATION

WALL SECTION

DRAWING NUMBER

OR LETTER

0'-0"

SURFACE

X X-X

IDENTIFICATION

ELEVATION

PARTICULAR ELEVATION OR LETTER

SHEET DETAILED ON

ELEVATION NUMBER

DRAWING TITLE

IDENTIFICATION

DETAIL/NAME

SCALE XX

ROOM NAME

XXX

X X-X

3624MILLWORK TYPE

106-1

KEY NOTE X

MARKER BOARD

TACK BOARD

INTERACTIVE WHITE BOARDMB

TB

WB

XXXX

REVISION NUMBER SYMBOLS &

ABBREVIATIONS

A-001

ZAXIS ARCHITECTURAL P.C.

THIS DOCUMENT, AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, ARE THE

PROPERTY OF ZAXIS ARCHITECTURAL P.C.

UNAUTHORIZED REPRODUCTION, ALTERATION OR ADDITION TO ANY DRAWING,

DESIGN, SPECIFICATION, PLAN OR REPORT IN WHOLE OR IN PART WITHOUT THE

EXPRESS WRITTEN AUTHORIZATION OF ZAXIS ARCHITECTURAL P.C. IS PROHIBITED BY

SECTION 7209, PROVISION 2 OF THE NEW YORK STATE EDUCATION LAW.

4245 UNION ROAD, SUITE 210

BUFFALO, NEW YORK 14225

P: 716.923.0133 F: 716.923.0136

No. REVISIONS DATE

DRAWING TITLE:

DATE: 4/10/2025

SCALE: AS SHOWN

DRAWN BY: SER

CHECKED BY:

PROJECT No: 25-008

DRAWING No.

architectural, p.c.

architecture � planning � consulting

- ISSUED FOR 100% REVIEW 8/20/2025

NYS OFFICE FOR PEOPLE

WITH DISABILITIES

703 EAST MAPLE AVENUE,

BUILDING 70, NEWARK, NEW

YORK 14513

KITCHEN REMODEL

PROJECT

LOCATED AT:

6469 SUNRAY CREST DRIVE,

VICTOR, NY 14564

- ISSUED FOR PERMIT & BID 9/5/2025

- REISSUED FOR PERMIT & BID 10/7/2025

CAPITAL SERVICES

DEMOLITION FLOOR PLAN

1/2" = 1'-0''

D1

D7 D2

D2

D2

D2 D3

REF.

MW MW

RANGE RANGE

DW DW

D1

D6

D7

REF.

D1

D8 D1

KITCHEN

PANTRY

D11

D13 D13

D13

D13

D13

D12 D11

D11

D14

D10

D9

D5

D10

D15

D6

D6

KEYED DEMOLITION NOTES

SALVAGE EXISTING APPLIANCES INCLUDING

REFRIGERATORS, ELECTRIC RANGES,

MICROWAVE AND DISHWASHER. STORE,

PROTECT AND MAINTAIN FOR REINSTALLATION.

DISCONNECT MICROWAVE DUCTWORK FOR

REINSTALLATION.

REMOVE AND DISPOSE OF ALL EXISTING KITCHEN

CABINETRY, COUNTERTOPS, SINK, BACKSPLASH,

ASSOCIATED TRIM, ETC.

REMOVE EXISTING DOOR, AND ASSOCIATED

HARDWARE.

EXISTING LIGHTING FIXTURE TO BE REMOVED

AND PROPERLY DISPOSED. CIRCUIT TO REMAIN

FOR RECONNECTION UNDER NEW WORK. PATCH

CEILING TO RECEIVE NEW WORK.

REMOVE WALL AS REQUIRED FOR NEW WALL

OPENING. REFER TO FLOOR PLAN FOR FRAMING

REQUIREMENTS. REMOVE RECEPTACLE AND

WIRING BACK TO PANEL.

REMOVE AND DISCARD EXISTING CORNER

GUARDS.

REMOVE EXISTING WALL-MOUNTED

ACCESSORIES INCLUDING BUT NOT LIMITED TO:

PAPER TOWEL DISPENSERS

SOAP DISPENSERS

HAND SANITIZER DISPENSERS

ETC.

EXISTING HALF-HEIGHT GATE TO BE REMOVED IN

PREPARATION FOR CONTRUCTION OF NEW

HALF-WALL.

EXISTING WALL OPENING TO REMAIN.

REMOVE ALL EXISTING FLOORING. PREPARE

AREA TO RECEIVE NEW FLOORING.

PATCH ALL AFFECTED WALL SURFACES AS

RESULT OF REMOVALS OF EXISTING CONDITION.

PATCH AS REQUIRED TO RECEIVE NEW WORK &

FINISHES.

EXISTING DOOR FRAME TO BE REMOVED. PATCH

TO PROVIDE A CASED DRYWALL OPENING V.I.F.

EXISTING OUTLET & SWITCH TO BE REMOVED.

EXISTING SHELVING TO BE REMOVED AND

DISCARDED.

REMOVE EXISTING GARBAGE DISPOSAL - SET

ASIDE FOR FUTURE REINSTALLATION.

D2

D3

D4

D5

D6

D7

D8

D1

D9

GENERAL DEMOLITION NOTES:

1. WHERE PLUMBING FIXTURES ARE

REMOVED: UNLESS OTHERWISE

NOTED, DRAIN LINES SHALL BE

REMOVED BACK TO WALL OR BELOW

FLOOR AS APPLICABLE AND CAPPED.

VENT LINES SHALL BE REMOVED

BACK TO ABOVE CEILING AND

CAPPED. HOT AND COLD WATER

LINES SHALL BE REMOVED BACK TO

WALL OR BELOW FLOOR, AS

APPLICABLE AND CAPPED.

2. WHERE APPLIANCES , LIGHT

FIXTURES, SWITCHES, RECEPTACLES

ARE REMOVED: UNLESS OTHERWISE

NOTED, WIRING SHALL BE REMOVED

BACK TO PANEL.

D10

D11

D12

D13

D14

D15

P2: KITCHENP1: EXISTING GATE P3: RANGE/BASE CABINETRY P5: EXISTING SINK P6: MILLWORK P7: PLUMBINGP4: MICROWAVE/WALL CABINETRY P9: PANTRYP8: DISHWASHERS & COUNTER

FLOOR PLAN

1/2" = 1'-0''

REF.

MW MW

RANGE RANGE

REF.

DWC2430W1230 W1230

B12

W

W

2 2

2 7

KITCHEN

8 9

PANTRY

3 3

3 3

DW DW

W2430 W2130

DWC2430

B24

15'-01 8"

6' -3

8"7'

-7 1 8"

9' -2

6'-93 4" 9'-71

8"

8"

W

B12

B18

B36

B18

B15

4 2

A-601

25 25

5A-601

KEYED CONSTRUCTION NOTES

PROVIDE & INSTALL TWO (2) NEW ULINE MOBILE SHELVING UNITS

MODEL NO. H-4254.

PROVIDE AND INSTALL NEW BASE AND WALL CABINETS, INCLUDING

MATCHING TRIM. BUTT TOP OF WALL CABINET TO BOTTOM OF

SOFFIT.

PROVIDE AND INSTALL NEW CUSTOM QUARTZ SURFACING

COUNTERTOPS WITH 4-INCH BACKSPLASH.

PROVIDE AND INSTALL NEW DOUBLE BOWL STAINLESS STEEL SINK

INCLUDING FAUCET,AND MANUAL STRAINER.

INSTALL SALVAGED DISHWASHERS. MODIFY AND RECONNECT TO

EXISTING PLUMBING AND POWER.

INSTALL SALVAGED REFRIGERATOR.

INSTALL SALVAGED RANGE.

PROVIDE AND INSTALL CERAMIC TILE BASIS OF DESIGN - DALTILE

MESMERIST; SPIRIT RECTANGLE UNDULATED - FROM TOP OF

QUARTZ BACKSPLASH TO UNDERSIDE OF UPPER CABINETS.

PREP, PRIME AND PAINT ALL WALLS, CEILINGS, SOFFITS AND

BULKHEADS IN THE AREA OF WORK.

PROVIDE AND INSTALL NEW SWITCHES, RECEPTACLES, INCLUDING

COVER PLATES. COLOR AS SELECTED BY OWNER. PROVIDE GFI

PROTECTED OUTLETS IN KITCHEN (TYPICAL)

PROVIDE AND INSTALL (2 FT.) UNDER CABINET LED LIGHT FIXTURE.

EXISTING SOFFIT TO REMAIN.

EXISTING SPRINKLER HEAD TO REMAIN. PROTECT DURING

CONSTRUCTION.

EXISTING SMOKE DETECTOR TO REMAIN. PROTECT DURING

CONSTRUCTION.

INSTALL NEW VINYL WALL BASE TO MATCH EXISTING IN KIND.

PROVIDE FLOORING TRANSITION STRIP.

PATCH ALL AREAS DISTURBED BY REMOVALS & NEW WORK TO

RECEIVE NEW FINISHES.

INSTALL NEW LIGHT FIXTURES AND CONNECT TO EXISTING

LIGHTING CIRCUIT.

INSTALL NEW 47

8" GWB HALF WALL. ALIGN WITH EXISTING WALL

LOCATION & PATCH/REPAIR WHERE NECESSARY.

INSTALL NEW 42" HALF-HEIGHT DOOR & FRAME AT NEW HALF WALL.

PROVIDE & INSTALL NEW DOOR LEAF. USE EXISTING FRAME &

DOOR HARDWARE. PAINT FRAME.

PROVIDE NEW FLOORING & BASE IN PANTRY.

EXISTING FLOORING TO REMAIN. PROTECT DURING

CONSTRUCTION. CLEAN.

REINSTALL GARBAGE DISPOSAL. CONNECT TO NEW SINK/PLUMBING

CONNECTIONS.

REINSTALL SALVAGED MICROWAVE - RECONNECT DUCTWORK.

PROVIDE & INSTALL NEW CORNER GUARDS BASIS OF DESIGN:

INPRO - 130 HIGH IMPACT CORNER GUARD. COLOR: CHINO 0258

26EXIST.

KITCHEN

SD

SD

D4

D4

DEMOLITION REFLECTED CEILING PLAN

1/2" = 1'-0''

D4 D4

D4

D4

D4

D4

REFLECTED CEILING PLAN

1/2" = 1'-0''

12 EXIST.

KITCHEN

SD

SD

AA

AA

A

A

A A

A

A

A

A

WALL

CABINET LINE

B

B

FLOORING

KITCHEN REMODEL FINISH LEGEND:

QUARTZ 1

QUARTZ

VINYL FLOOR (LVP-1)

MFGR: CORETEC

COLOR: VV012-00760 MANILA OAK

PRODUCT: CORETEC ORIGINALS

WITH 4" ROPPE VINYL WALL BASE - 677 GINGERBREAD

PAINTS

PAINT (WALLS)

COLOR: HC-81 MANCHESTER TAN

FINISH:SEMI-GLOSS

MFGR: BENJAMIN MOORE

PAINT (CEILING)

COLOR: OC-57 WHITE HERON

FINISH: SEMI-GLOSS

MFGR: BENJAMIN MOORE

MFGR: CORIAN

COLOR: BIANCO DOLOMITE

LOCATION: COUNTERTOP

SINK: KOHLER UNDERTONE K-3350-NA

PORCELAIN TILE

WALL TILE

MFGR: DALTILE

COLOR: MESMERIST: SPIRIT

LOCATION: WALL UNDER CABINET

SHAPE: HEXAGON UNDULATED

GROUT: LATICRETE #23 ANTIQUE WHITE

FLOOR PLANS &

CEILING PLANS

A-101

4245 UNION ROAD, SUITE 210

BUFFALO, NEW YORK 14225

P: 716.923.0133 F: 716.923.0136

No. REVISIONS DATE

DRAWING TITLE:

DRAWING No.

architectural, p.c.

architecture � planning � consulting

DATE: 6/20/2025

SCALE: AS SHOWN

DRAWN BY: SER

CHECKED BY:

PROJECT No: 25-008

ISSUED FOR 100% REVIEW 8/20/2025

NYS OFFICE FOR PEOPLE

WITH DISABILITIES

703 EAST MAPLE AVENUE,

BUILDING 70, NEWARK, NEW

YORK 14513

KITCHEN REMODEL

PROJECT

LOCATED AT:

6469 SUNRAY CREST DRIVE,

VICTOR, NY 14564

- ISSUED FOR PERMIT & BID 9/5/2025

- REISSUED FOR PERMIT & BID 10/7/2025

CAPITAL SERVICES

W3615

B36B18

W2430

BD24 B18EXISTING

DW

EXISTING

DW

W2130 DWC2430

B18

W1830 W1830 DCW2430

SOFFIT (PAINT)SOFFIT (PAINT)

W1230 W1230

SOFFIT (PAINT)

EXISTING

RANGE

EXISTING

RANGE B12

DWC2430DCW2430

B12

EXISTING

MW

EXISTING

MW

8' -1

V.

I.F

3' -6

2' -1

2"

2"

4" 1'

-0 1 2"

2' -6

1'

-2 1 2"

4' -7

V.

I.F

GFI GFI

SOFFIT

(PAINT)

EXISTING DOOR FRAME

TO BE REMOVED - PATCH

TO PROVIDE A DRYWALL

CASED OPENING

SOFFIT

(PAINT)

(OPEN)

CAPGFI GFI

GFI

EXISTING SPRINKLER

TO REMAIN

KITCHEN ELEVATION 1

KITCHEN ELEVATION 2

KITCHEN ELEVATION 3

KITCHEN ELEVATION 4

3' -4

1'-1" 3'-4" 1'-5"

1' -2

1 2" 2'

-6

1' -0

1 2"

EXISTING TO

REMAIN (REFINISH)

3' -6

GFI

(PAINT)

EXISTING FIRE

EXTINGUISHER

(OPEN)

4" VINYL

BASE

EXISTING

CHAIR RAIL

TO REMAIN

4" VINYL

BASE

4" VINYL

BASE

2'-0"6'-47 8"47

8"9'-71 8"10'-53

4"16'-47 8"

4" QUARTZ TO

MATCH COUNTER

WALL CAP DETAIL A

6" (V.I.F.)

4"

4"

DOOR DETAILS

1 1/2" = 1'-0''

4"

2X4 WD STUDS

B

J1 - JAMB DETAIL

WD CASING,

MATCH EXIST.

ADJACENT

5/8" GWB EA.

SIDE SIDE

W3615

W1830 W1830DCW2430

GFI

EXISTING SPRINKLER

TO REMAIN

KITCHEN ELEVATION 5

(PAINT TO

MATCH

EXISTING)

SOFFIT

(PAINT)

CAP

8' -1

V.

I.F

3'-83 4"3'-4"3'-5"

1' -2

1 2" 2'

-6

1 2"

3' -6

SOFFIT

(PAINT)

CHAIR RAIL

TO MATCH

EXISTING

VIF

4" VINYL

BASE

4" VINYL

BASE

CHAIR RAIL

TO MATCH

EXISTING

VIF

INTERIOR

ELEVATIONS &

DETAILS

A-601

4245 UNION ROAD, SUITE 210

BUFFALO, NEW YORK 14225

P: 716.923.0133 F: 716.923.0136

No. REVISIONS DATE

DRAWING TITLE:

DRAWING No.

architectural, p.c.

architecture � planning � consulting

DATE: 4/10/2025

SCALE: AS SHOWN

DRAWN BY: SER

CHECKED BY:

PROJECT No: P25023

ISSUED FOR 100% REVIEW 8/20/2025

NYS OFFICE FOR PEOPLE

WITH DISABILITIES

703 EAST MAPLE AVENUE,

BUILDING 70, NEWARK, NEW

YORK 14513

KITCHEN REMODEL

PROJECT

LOCATED AT:

6469 SUNRAY CREST DRIVE,

VICTOR, NY 14564

- ISSUED FOR PERMIT & BID 9/5/2025

- REISSUED FOR PERMIT & BID 10/7/2025

CAPITAL SERVICES

DIVISION 1 - GENERAL REQUIREMENTS

1A. GENERAL NOTES

1. THE WORK OF THE CONTRACTOR SHALL PROVIDE LABOR, MATERIALS, TOOLS,

EQUIPMENT, SERVICES, ETC. NECESSARY OR INCIDENTAL TO HIS PORTION OF THE

WORK SHOWN ON THE DRAWINGS AND HEREIN SPECIFIED, SHOP DRAWINGS AND/OR

SAMPLES SHALL BE SUBMITTED TO THE ARCHITECT FOR REVIEW FOR ALL WORK OR

MATERIALS REQUIRING FABRICATION, QUALITY APPROVAL, OR COLOR SELECTION.

2. THE CONTRACTOR SHALL ORDER AND HAVE ALL MATERIALS AVAILABLE BEFORE

STARTING HIS WORK, TO INSURE THAT ONCE THE WORK IS STARTED, IT SHALL

PROCEED CONTINUOUSLY UNTIL COMPLETE.

3. THE CONTRACTOR SHALL ASCERTAIN THE LOCATION OF ALL UTILITY LINES AND TAKE

PROPER PRECAUTION NOT TO DISTURB ANY EXISTING UTILITIES UNLESS

AUTHORIZED. THE CONTRACTOR SHALL BE HELD RESPONSIBLE FOR ANY DAMAGE TO

UTILITY LINES DURING THE PROCESS OF WORK UNDER THE CONTRACT.

4. THE CONTRACTOR SHALL CAREFULLY EXAMINE THE DRAWINGS AND SPECIFICATIONS

AND VERIFY THE PROVISIONS ARE ADEQUATE FOR THE PROPER INSTALLATION OF

EACH ITEM. SHOULD THERE BE ANY CONDITION THAT WILL PREVENT A THOROUGHLY

SATISFACTORY INSTALLATION, THE CONTRACTOR SHALL NOTIFY THE ARCHITECT OR

OWNER, PRIOR TO BEGINNING WORK. FAILURE OF NOTIFICATION WILL CONSTITUTE

ACCEPTANCE OF THE CONDITIONS, AND THE CONTRACTOR SHALL MAKE ANY

NECESSARY CHANGES TO PROPERLY ACCOMMODATE EACH ITEM AT HIS/HER COST.

5. ALL WORK MUST COMPLY WITH NEW YORK STATE BUILDING CONSTRUCTION CODE,

AISC CODE, ACI BUILDING CODE, AWI CODE, ASTM STANDARDS AND ANY OTHER

APPLICABLE CODE, RULES AND REGULATION BY AGENCIES HAVING JURISDICTION.

WHERE CODES OVERLAP, COMPLY WITH THE MORE STRINGENT REQUIREMENTS.

6. CONTRACTOR IS TO REVIEW DRAWINGS AND EXISTING SITE CONDITIONS AND

DIMENSIONS FOR SCOPE OF THE WORK INVOLVED. CONTRACTOR IS TO INCLUDE, IN

HIS/HER PROPOSAL, ALL ITEMS, MATERIALS, ETC. TO ACHIEVE THE DESIGN CONCEPT

AS SHOWN ON THE DRAWINGS.

7. CONTRACTOR IS TO INCLUDE IN HIS/HER PROPOSAL ALL ADDITIONAL MATERIALS AND

LABOR AS REQUIRED TO WORK AROUND EXISTING CONDITIONS.

8. CONTRACTOR IS RESPONSIBLE FOR ALL MEANS, METHODS, LABOR PROCEDURES

AND SAFETY PRECAUTIONS FOR COMPLETING WORK.

9. THE COST OF ALL INSTALLATION OF TEMPORARY SERVICE LINES REQUIRED FOR

COMPLETION OF THE PROJECT SHALL BE BORNE BY THE GENERAL CONTRACTOR.

10. ALL WORKMANSHIP MUST BE IN THE BEST PRACTICE OF THE TRADE AS DETERMINED

BY THE ARCHITECT OR OWNER. ANY WORK NOT MEETING THESE STANDARDS WILL

BE REJECTED.

11. WHERE A SPECIFIC MANUFACTURER'S PRODUCT IS CALLED OUT, ALL MATERIALS AND

WORK MUST COMPLY WITH THE MANUFACTURER'S STRICT RECOMMENDATIONS FOR

INSTALLATION AND/OR COORDINATION. IT IS THE CONTRACTOR'S RESPONSIBILITY TO

OBTAIN INSTRUCTIONS AND TO FOLLOW THEM.

DIVISION 2 - SELECTIVE DEMOLITION

2A. SUMMARY

1. SECTION INCLUDES DEMOLITION AND REMOVAL OF SELECTED PORTIONS OF

BUILDING OR STRUCTURE.

2B. FIELD CONDITIONS

1. OWNER WILL OCCUPY PORTIONS OF BUILDING IMMEDIATELY ADJACENT TO

SELECTIVE DEMOLITION AREA. CONTRACTOR SHALL PROVIDE, TO THE GREATEST

EXTENT POSSIBLE, TEMPORARY ACCOMMODATIONS FOR OWNER DURING

DEMOLITION FOR NECESSARY UTILITIES.

2C. EXAMINATION

1. VERIFY THAT ANY ADJACENT UTILITIES HAVE BEEN DISCONNECTED AND CAPPED

BEFORE STARTING DEMOLITION OPERATIONS.

2. SURVEY EXISTING CONDITIONS AND CORRELATE WITH REQUIREMENTS INDICATED TO

DETERMINE EXTENT OF SELECTIVE DEMOLITION REQUIRED.

3. WHEN UNANTICIPATED MECHANICAL, ELECTRICAL OR STRUCTURAL ELEMENTS

CONFLICT WITH INTENDED FUNCTION OR DESIGN ARE ENCOUNTERED, INVESTIGATE

AND SUBMIT TO FIELD REPRESENTATIVE.

2D. UTILITY SERVICES

1. EXISTING SERVICES: MAINTAIN AND PROTECT EXISTING SERVIVCES/SYSTEMS TO

REMAIN.

2. EXISTING SYSTEMS/SERVICES TO BE REMOVED, RELOCATED OR ABANDONED:

LOCATE, IDENTIFY, DISCONNECT AND SEAL OR CAP OFF UTILITY SERVICES TO BE

SELECTIVELY DEMOLISHED.

2E. PREPARATION

1. SITE ACCESS: CONDUCT SELECTIVE DEMOLITION AND DEBRIS REMOVAL OPERATIONS

TO ENSURE MINIMUM INTERFERENCE WITH ROADS, WALKWAYS, ETC. REPAIR ALL

LAWN AREAS AFFECTED BY DEMOLITION/CONSTRUCITON.

2. TEMPORARY FACILITIES: PROVIDE TEMPORARY BARRICADES AND OTHER

PROTECTION REQUIRED TO PREVENT INJURY TO PEOPLE AND DAMAGE TO

BUILDINGS.

2F. SELECTIVE DEMOLITION, GENERAL

1. GENERAL: DEMOLISH AND REMOVE EXISTING CONSTRUCTION ONLY TO THE EXTENT

REQUIRED BY NEW CONSTRUCTION.

2G. DISPOSAL

1. GENERAL: EXCEPT FOR ITEMS OR MATERIALS INDICATED TO REMAIN, REMOVE

DEMOLISHED MATERIALS FROM SITE.

2. TRANSPORT DEMOLISHED MATERIALS OFF OWNER'S PROPERTY AND LEGALLY

DISPOSE OF THEM.

DIVISION 6 - WOOD AND PLASTICS

6A. ROUGH CARPENTRY

1. THE TERM "LUMBER" SHALL INCLUDE ALL ROUGH CARPENTRY WOODWORK,

TEMPORARY AND PERMANENT. ALL LUMBER SHALL BE TRADE AND GRADE MARKED,

OR ACCOMPANIED BY A GRADING CERTIFICATE OF THE ASSOCIATION UNDER WHOSE

RULES IT WAS GRADED AND SHIPPED AND AN AFFIDAVIT CERTIFYING ALL SUCH

LUMBER DELIVERED TO THIS PROJECT TO BE OF THE KIND AND GRADE SPECIFIED.

2. ALL LUMBER SHALL BE WELL-SEASONED AND AIR OR KILN DRIED. FRAMING LUMBER

SHALL BE DELIVERED TO THE JOB SITE WITH MOISTURE CONTENT NOT EXCEEDING

19 PERCENT AS CERTIFIED BY THE SUPPLIER.

3. GLUE FOR ALL WORK - WATERPROOF TYPE.

4. ROUGH HARDWARE, EXCEPT AS OTHERWISE SPECIFIED HEREIN, SHALL BE AS

REQUIRED FOR PROPER EXECUTION OF WORK IN THIS SECTION AND SHALL BE

HOT-DIPPED GALVANIZED STEEL OR OTHER APPROVED NON-CORROSIVE METAL.

5. FURNISH AND INSTALL ALL WOOD FOR SECURING ALL INDICATED ITEMS

THROUGHOUT BUILDING, INCLUDING GROUNDS REQUIRED BY ITEMS FURNISHED BY

OTHERS. ALL LUMBER TO BE EVEN, PLUMB, STRAIGHT AND SECURED BY APPROVED

METHOD AND FOR INTENDED PURPOSE. TREAT ALL MISCELLANEOUS CARPENTRY

UNLESS OTHERWISE INDICATED AS WELL AS CONCEALED BLOCKING AND PLYWOOD

BACKING PANELS.

6. PROVIDE ALL ROUGH HARDWARE NECESSARY IN CONNECTION WITH ROUGH

CARPENTRY, ROUGH HARDWARE SHALL INCLUDE THREADED DOWELS, SCREWS,

BOLTS (ALL TYPES), WASHERS, ANCHORS FOR MASONRY, PLASTER AND CONCRETE,

CLIPS AND OTHER SUCH FASTENERS AND MISCELLANEOUS TRIM THAT MAY BE

PURCHASED WITHOUT FURTHER FABRICATION.

7. ALL MEMBERS SHALL BE ADEQUATELY FASTENED TOGETHER TO PREVENT RELATIVE

MOVEMENT AT JOINTS UNDER THE MAXIMUM LOAD FOR WHICH THE MEMBERS ARE

SIZED.

8. FRAMING NAILS SHALL BE UNCOATED COMMON NAILS OF SUFFICIENT LENGTH TO

PENETRATE 12 DIAMETERS INTO HOLDING MEMBER.

9. ALL WORK SHALL BE TRUE, PLUMB, LEVEL AND ACCURATELY CUT AND FIT.

10. PLYWOOD SHALL BE ERECTED AND FASTENED TO FRAMING MEMBERS IN

ACCORDANCE WITH THE PUBLISHED RECOMMENDATIONS OF THE APA.7.MATERIALS -

PROVIDE THE FOLLOWING:

A. PLYWOOD - APA RATED - EXT GLUE

B. MEDIUM DENSITY FIBERBOARD - ANSI A208.2, GRADE MD, MADE WITH BINDER

CONTAINING NO UREA FORMALDEHYDE.

11. MAXIMUM MOISTURE CONTENT OF LUMBER: 19 PERCENT UNLESS OTHERWISE

INDICATED.

12. FIRE-RETARDANT-TREATED LUMBER AND PLYWOOD BY PRESSURE PROCESS:

PRODUCTS WITH A FLAME SPREAD INDEX OF 25 OR LESS WHEN TESTED

ACCORDING TO ASTM E 84, AND WITH NO EVIDENCE OF SIGNIFICANT

PROGRESSIVE COMBUSTION WHEN THE TEST IS EXTENDED AN ADDITIONAL 20

MINUTES, AND WITH THE FLAME FRONT NOT EXTENDING MORE THAN 10.5 FEET

(3.2 M) BEYOND THE CENTERLINE OF THE BURNERS AT ANY TIME DURING THE

TEST.

A. INTERIOR TYPE A: TREATED MATERIALS SHALL HAVE A MOISTURE CONTENT

OF 19% MAX WHEN TESTED ACCORDING TO ASTM D 3201 AT 92 PERCENT

RELATIVE HUMIDITY.

13. PROVIDE MISCELLANEOUS LUMBER INDICATED AND LUMBER FOR SUPPORT OR

ATTACHMENT OF OTHER CONSTRUCTION, INCLUDING BLOCKING AND NAILERS.

14. COUNTERTOPS - SHALL BE QUARTZ SURFACING COUNTERTOPS. COLOR TO BE

SELECTED BY HOUSE DIRECTOR FROM MANUFACTURER'S MID-LEVEL RANGE.

A. ACCEPTABLE MANUFACTURERS INCLUDE:

1) CAMBRIA

2) CORIAN

3) APPROVED EQUAL

B. CONSTRUCTED OF QUARTZ SURFACING MATERIAL OF MANUFACTURER'S

STANDARD THICKNESS.

C. PROVIDE HOLES AND CUTOUTS FOR PLUMBING ACCESSORIES AS

INDICATED ON THE DRAWINGS AND AS REQUIRED.

D. EDGE BASIS OF DESIGN: DOUBLE TREELINE EDGE (A+R).

E. FINISH BASIS OF DESIGN: POLISHED FINISH.

F. REVIEW EDGE AND FINISH WITH OWNER PRIOR TO ORDERING.

15. BACKSPLASHES

A. INTEGRALLY JOIN INTERSECTION OF COUNTERS AND BACKSPLASHES.

FORM BACKSPLASHES USING MATCHING THICKNESS QUARTZ SURFACING

MATERIAL.

16. INSTALLATION

A. INSTALL PLUMB AND LEVEL PER APPROVED PRODUCT INSTALLATION

DETAILS. FORM FIELD JOINTS USING MANUFACTURER'S RECOMMENDED

ADHESIVE WITH INCONSPICUOUS JOINTS.

B. TRIM: INSTALL WITH MINIMUM NUMBER OF JOINTS POSSIBLE, USING

FULL-LENGTH PIECES WITH NO MORE THAN 1/8" VARIATION FROM A

STRAIGHT LINE.

C. CABINETS: INSTALL WITHOUT DISTORTION SO DOORS AND DRAWERS FIT

OPENINGS PROPERLY AND ARE ACCURATELY ALIGNED. ADJUST HARDWARE

TO CENTER DOORS AND DRAWERS IN OPENINGS AND TO PROVIDE

UNENCUMBERED OPERATION.

D. COUNTERTOPS: INSTALL COUNTERTOPS IN STRICT ACCORDANCE WITH

MANUFACTURER'S WRITTEN INSTRUCTIONS AND RECOMMENDATIONS.

CAULK BETWEEN BACKSPLASH AND WALL IN STRICT ACCORDANCE WITH

MANUFACTURER'S WRITTEN INSTRUCTIONS AND RECOMMENDATIONS.

6B. FINISH CARPENTRY

1. SECTION INCLUDES THE FOLLOWING:

- KITCHEN CABINETS

2. PROVIDE A WOOD FURRING, BLOCKING, SHIMS AND HANGING STRIPS FOR

INSTALLING WOODWORK ITEMS.

3. SUBMITTALS - PROVIDE CABINET LAYOUT DRAWINGS WHICH INDICATE LOCATION

OF EACH ITEM, DIMENSIONS, PLANS AND ELEVATIONS.

4. COLORS TO BE SELECTED FROM MANUFACTURER'S STANDARD RANGE OF

SAMPLES UNLESS OTHERWISE SPECIFIED.

5. FABRICATOR AND INSTALLER SHALL BE EXPERIENCED IN PRODUCING AND

INSTALLING ARCHITECTURAL WOODWORK AND WHOSE RECORD HAS

PRODUCED SUCCESSFUL RESULTS.

A. FABRICATOR SHALL VERIFY DIMENSIONS IN FIELD PRIOR TO FABRICATIONS.

6. KITCHEN CABINET MANUFACTURERS

A. GENERAL: PROVIDE AMERICAN WOODMARK, ALL PLYWOOD

CONSTRUCTION (APC), PARTIAL OVERLAY CABINETS OR APPROVED EQUAL.

7. FINISH HARDWARE

A. ADJUSTABLE SHELF STANDARDS AND SUPPORTS - BHMA-A156.9, B05091.

B. EXPOSED HARDWARE - FINISH TO BE SELECTED BY HOUSE DIRECTOR.

8. SHELVING

A. MADE FROM 3/4 INCH (19 MM) THICK PLYWOOD WITH PLASTIC LAMINATE

FINISH.

B. GLUE: ALIPHATIC-RESIN, POLYURETHANE, OR RESORCINOL WOOD GLUE

RECOMMENDED BY MANUFACTURER FOR GENERAL CARPENTRY USE.

C. WOOD GLUE SHALL HAVE A VOC CONTENT OF 30 g/L OR LESS WHEN

CALCULATED ACCORDING TO 40 CFR 59, SUBPART D (EPA METHOD 24).

9. INSTALL INTERIOR FINISH CARPENTRY LEVEL, PLUMB, TRUE AND ALIGNED WITH

ADJACENT MATERIALS. USE CONCEALED SHIMS WHERE NECESSARY FOR

ALIGNMENT.

A. SCRIBE AND CUT INTERIOR FINISH CARPENTRY TO FIT ADJOINING WORK.

REFINISH AND SEAL CUTS AS RECOMMENDED BY MANUFACTURER.

10. INSTALL WOODWORK LEVEL, PLUMB, TRUE AND STRAIGHT TO A TOLERANCE OF

1/8 INCH IN 96 INCHES (3 MM IN 2400 MM). SHIM AS REQUIRED WITH CONCEALED

SHIMS.

11. SCRIBE AND CUT WOODWORK TO FIT ADJOINING WORK, REFINISH CUT

SURFACES, AND REPAIR DAMAGED FINISH AT CUTS.

DIVISION 7 - THERMAL AND MOISTURE PROTECTION

7A. SEALANTS:

1. COMPATIBILITY: PROVIDE JOINT SEALERS, JOINT FILLERS AND OTHER RELATED

MATERIALS THAT ARE COMPATIBLE WITH ONE ANOTHER AND WITH JOINT

SUBSTRATES UNDER SERVICE AND APPLICATION CONDITIONS, AS

DEMONSTRATED BY TESTING AND FIELD EXPERIENCE.

2. COLORS: PROVIDE COLOR OF EXPOSED JOINT SEALERS AS SELECTED BY

ARCHITECT FROM MANUFACTURER'S STANDARD COLORS.

3. CLEAR SILICONE, MILDEW RESISTANT JOINT SEALANT INTERIOR SURFACES: ONE

PART, NEUTRAL CURE, MEDIUM MODULES COMPLYING WITH FS-TT-S 001543A BY

DOW CORNING #791 OR APPROVED EQUAL. DOW CORNING #786 NT PLUMBING

FIXTURES - ANTI-MICROBIAL.

DIVISION 8 - DOORS AND WINDOWS

8A. WOOD DOORS

1. PROVIDE NEW DOOR, DOOR LEAVES SOLID CORE 5 PLY BIRCH VENEER BY

MOHAWK OR APPROVED EQUIVALENT

2. EXISTING DOOR FRAME TO BE REFINISHED. PREP AND PAINT

3. PROVIDE/INSTALL PR HINGES HAGAR US26D

4. PROVIDE/INSTALL DOOR STOP HAGER 230W WALL STOP

5. PROVIDE/INSTALL PRIVACY LOCKSET HAGAR 2500 SERIES

DIVISION 9 - FINISHES

9A. GYPSUM WALLBOARD

1. GYPSUM WALLBOARD SHALL BE MOISTURE AND MOLD-RESISTANT BOARD:

ASTMC 1396/C 1396 M, WITH MOISTURE AND MOLD-RESISTANT CORE AND PAPER

SURFACES. 12" or 5 8" THICKNESS WITH TAPERED EDGE AS MANUFACTURED BY

GEORGIA PACIFIC OR APPROVED EQUAL.

2. PROVIDE SOLID FIRE TREATED BLOCKING IN PARTITIONS REQUIRED TO

SUPPORT FIXTURES, GRAB BARS, CASEWORK AND ANY ACCESSORIES.

3. ALL PARTITIONS TO BE TAPED, SANDED AND FINISHED SMOOTH TO RECEIVE

PAINT (LEVEL 4 FINISH PER ASTM C840).

9B. FLOOR FINISHES

1. LUXURY VINYL PLANK (LVP) TO BE AS FOLLOWS OR EQUAL:

MANUFACTURER: CORETEC

PRODUCT: CORETEC ORIGINALS

SIZE: 7" X 48" TILE

COLOR: VV012-00760

2. THERMOPLASTIC / VINYL WALL BASE TO BE AS FOLLOWS OR EQUAL:

MANUFACTURER: ROPPE CORPORATION

PRODUCT: 700 SERIES (THERMOPLASTIC RUBBER AND VINYL BLEND)

TYPE: COVE AT VINYL FLOORING

SIZE: 4" HIGH

COLOR: 677 - GINGERBREAD

9C. PAINTING:

1. GYPSUM BOARD SUBSTRATES

A. SATIN EMULSION FINISH LATEX SYSTEM: 3 COATS (TOTAL DRY FILM

THICKNESS: 4.6 MIL)

1) FIRST COAT: INTERIOR LATEX BASE PRIMER COAT (FS TT-P-650)

BENJAMIN MOORE: MOORECRAFT SUPER-SPEC LATEX ENAMEL

UNDERCOATER & PRIMER #253

2) SECOND & THIRD COAT: INTERIOR MILDEW-RESISTANT LATEX PAINT

BENJAMIN MOORE: MOORECRAFT SUPER SPEC LATEX SEMI-GLOSS

ENAMEL #276

PLUMBING FIXTURES

FIXTURE MATERIAL STANDARD ACCESSORIES NOTES

GENERAL FIXTURE NOTES:

1. INSTALL ALL PRODUCTS IN ACCORDANCE WITH THE MANUFACTURER'S WRITTEN INSTALLATION INSTRUCTIONS.

2. PROVIDE ALL SEALS, GASKETS, SEALING MATERIALS TO MAKE COMPLETE WATER TIGHT AND GAS TIGHT SYSTEMS.

3. SET ALL FIXTURES PLUMB AND TRUE.

LUMINAIRE SHCEDULE

TYPE SYMBOL LUMINAIRE DESCRIPTION LIGHT

SOURCE

DESIGN BASIS

OR EQUAL

VOLTAGE

A

B

6" DIA. RECESSED

DOWNLIGHT, RATED FOR

INSUL. CEILINGS, DIMMABLE

24" LONG UNDERCABINET STRIP,

WHITE, ROCKER SWITCH,

ADJUSTABLE CCT PROVIDE

CONNECTORS AS REQUIRED

LED

2000LMS

21W 3000°K

UNIV

LED

1095Lm 17.5W 3000°K

NDR MODEL RZR-CCT-600

REFLECTOR & TRIM RING:

WHITE

WAC LIGHTING

MODEL #BA-ACLED24-27/30WT

KITCHEN

PULL-OUT FAUCET

POLISHED CHROME FINISH 1. ICC/ ANSI A117.1

2. ASME A112.18.1

1. SINK SUPPLIES 3 8"

2. P-TRAP

1. MFR: MOEN "RENZO" PULL-OUT FAUCET

2. MODEL: CA87316C

3. SINGLE LEVER HANDLE

4. 1.5 GPM MAXIMUM FLOW RATE

KITCHEN SINK

DOUBLE BOWL

#18 GAUGE, TYPE 304

STAINLESS STEEL -

DOUBLE BOWL -

UNDERMOUNT

ASME A112.19.3 1. MANUFACTURER: KOHLER "UNDERTONE"

2. MODEL: K-3350-NA

3. NOMINAL DIMENSIONS: 31-1/2"

4. DEPTH: 7-1/2"

5. MINIMUM BASE CABINET SIZE: 36"

KOHLER

DUOSTRAINER WITH

TAILPIECE

MODEL: K8801-CP

SPECIFICATIONS

SP-101

ZAXIS ARCHITECTURAL P.C.

THIS DOCUMENT, AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, ARE THE

PROPERTY OF ZAXIS ARCHITECTURAL P.C.

UNAUTHORIZED REPRODUCTION, ALTERATION OR ADDITION TO ANY DRAWING,

DESIGN, SPECIFICATION, PLAN OR REPORT IN WHOLE OR IN PART WITHOUT THE

EXPRESS WRITTEN AUTHORIZATION OF ZAXIS ARCHITECTURAL P.C. IS PROHIBITED BY

SECTION 7209, PROVISION 2 OF THE NEW YORK STATE EDUCATION LAW.

4245 UNION ROAD, SUITE 210

BUFFALO, NEW YORK 14225

P: 716.923.0133 F: 716.923.0136

DRAWING TITLE:

DRAWING No.

architectural, p.c.

architecture � planning � consulting

No. REVISIONS DATE

SCALE: AS SHOWN

DRAWN BY: SER

CHECKED BY:

PROJECT No: 25-008

DATE: 4/10/2025

- ISSUED FOR 100% REVIEW 8/20/2025

NYS OFFICE FOR PEOPLE

WITH DISABILITIES

703 EAST MAPLE AVENUE,

BUILDING 70, NEWARK, NEW

YORK 14513

KITCHEN REMODEL

PROJECT

LOCATED AT:

6469 SUNRAY CREST DRIVE,

VICTOR, NY 14564

- ISSUED FOR PERMIT & BID 9/5/2025

- REISSUED FOR PERMIT & BID 10/7/2025

CAPITAL SERVICES

25-008 SUNRAY CREST KITCHEN CS-101 COVER SHEET.pdf
Sheets and Views
COVER SHEET
25-008 SUNRAY CREST KITCHEN A-001 PARTITION TYPES.pdf
Sheets and Views
A-001
25-008 SUNRAY CREST KITCHEN A-101 FLOOR PLAN.pdf
Sheets and Views
A-101
25-008 SUNRAY CREST KITCHEN A-601 FLOOR PLAN.pdf
Sheets and Views
A-601
25-008 SUNRAY CREST KITCHEN SP-101 SPECIFICATIONS.pdf
Sheets and Views
SP-101

File details come from the government source that posted it. Updated .