Appendix A - SAT CR1 Cable Tray Plan.pdf
PDF 853 KB Posted
- Attached to
- Cable Tray Support Replacement Federal contract opportunity
- Solicitation number
- HC102821R0063
- Issued by
- Defense Information Systems Agency
About this file
This document contains reflected ceiling plans and cable tray plans for computer rooms at a Defense Information Systems Agency data center. The plans show the existing layout of cable trays, air handling units, power distribution units, fire alarm panels, and other infrastructure throughout rooms 141, 142 and 143. The related federal contract opportunity is seeking proposals to replace the existing floor mounted cable tray support stanchions with an overhead suspension system in Computer Room 1 to meet Department of Defense core data center architecture standards. The solicitation number is HC102821R0063 and was issued by the Defense Information Systems Agency for a cable tray support replacement project in the specified computer room.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| CLIN Amount Spreadsheet.xlsx | XLSX spreadsheet | |
| Pre-Proposal Site Visit Request Instructions Cable Tray.doc | DOC document | |
| HC102821R0063 Solicitation RFP.pdf | ||
| Appendix B - As-Built Sections Drawing_Sheet A-6.pdf | ||
| Appendix C - Cable Trays Specification.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
CORRIDOR
130A
JANITOR
CONFERENCE
CORRIDOR
PROJECTOR
CORRIDOR
BATTERY ROOM
CORRIDOR
VESTIBULE
ELECTRICAL ROOM
117 TELECOM/COMM
NIPR COMPUTING SPACE
CORRIDORSTORAGE
M
M
CAM
CAM
CAM
CAM
CAM
M
CAM
CAM
CAM RL RL
RL
RL
RL H
H
H H H
CAM
CAM
M
M
M
M
M M
CAM
VCP VCP VCP VCP VCP VCP VCP VCP
CA
ALARM
CA
ALARM
SHEET
IDENTIFICATION
D
ES
IG
N
B Y:
D R
AW
N
B Y:
SU
BM
IT
TE
D B
Y:
PL
O
T
SC
AL
E:
SI
ZE
AN
SI
D
C H
EC
KE
D B
Y:
PL
O
T D
AT
E:
FI
LE
N
AM
E:
SU
BM
IT
TA
L D
AT
E:
SO
LI
C
IT
AT
IO
N N
O
C O
N
TR
AC
T
N O
FI
LE
N U
M
BE
R
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E:
AP
PR
M
AR
K
D
ES
C R
IP
TI
O N
D
AT
E:
AP
PR
B
C
D
1 2 3 4 5
1 2 3 4 5
Defense Information Systems Agency A Combat Support Agency
A
B
D
C
P.
O
.B O
X
G
R
EE
N W
O O
D V
IL
LA
G E
SE
L
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G
C O
.8
234567 14 13 12 11 10 9 8
* FOR OFFICIAL USE ONLY *
* FOR OFFICIAL USE ONLY *
A
A-100
D
AT
A C
EN
TE
R S
AN
A
N
TO
N
IO
C R
C
EI
LI
N G
A N
D C
AB
LE
T R
AY
R
EF
LE
C
TE
D
C
EI
LI
N
G P
LA
N
C R
AR
C H
IT
EC
TU
R
AL
D
ES
IG
N
IN
TE
N
T
G W
JE
S
AS
S
H O
W N
JE
S
6/ 3/
SA
T
A- C
P1
.D W
G
/1
6/
0 4' 8' 16'
REFLECTED CEILING PLAN CR1
SCALE :1/8" = 1'-0"
N
PLAN
NORTH
KEY PLAN
SCALE: NTS
MATCH LINE CONTINUED
ON AREA C SHEET A-110
M
AT
C H
L
IN
E C
O N
TI
N
U
ED
O N
A R
EA
B
S H
EE
T
A-
A
PD
U
Z O
N E
PD
U
Z O
N E
PD
U
Z O
N E
PDU ZONE
12 (FULL)
PD
U
Z O
N E
PDU ZONE 10
PDU ZONE 08
PDU ZONE
PDU ZONE
PDU
ZONE 04
PD
U
Z O
N E
PD
U
Z O
N E
PD
U
Z O
N E
PDU
ZONE
PD
U
Z O
N E
NIPR COMPUTING SPACE
CORRIDOR
SIPR OPEN STORAGE/OFFICE
OFFICE
CORRIDOR
CONFERENCE
CORRIDOR
VESTIBULE
ELECTRICAL ROOM
TELECOM/COMM
CORRIDOR
145B
CORRIDOR
145A
MENS
WOMENS
OFFICE
OFFICE
OFFICE
STORAGE
OFFICE
155 R
AM
P
D O
W N
BZBY CECDCCCBCA
CSCRCQCP CVCUCT CW CX CY
CSCRCQCP CW CXCVCUCT CY
BI BJ
CSCRCQCP
CRCQCKCJCICHCGCFCDCCCB
BVBUBTBSBR BWBQBPBK BMBCBBBAAZAW AXAV AYAUATAP AQAL AM
CABZBYBXBWBVBUBTBSBRBQBPBOBNBLBKBJBIBHBGBFBEBDBCBBBAAZAYAXAWAVAUAS AT BMA B C D E F G H I J K L M N O P Q R S T U V W X Y Z AA AB
AC AD AE AF AG AH AI AL AM AN AO
A B C D E F G H I J K L M N O P Q R S T U V W X Y Z AA AB AC AD AE AF AG AH
AP AQ AR
ASAN AO AR BLBHBGBFBEBD BOBN
CA CE CPCO CS CT CU CV CY
CYCX
CYCW CXCVCUCT
CJ CKCICHCGCD CE CFCCCBCABZBYBXBD BGBFBE BLBKBJBIBH BVBSBR BWBM BUBTBQBPBOBNBCBA BBAZAYAXAWAVAUATASARAQAPAN AO
DB
DA
CKCJCICHCGCF
DA
DBDA
DB
72 72
CW CX
AI AJ AK
CZ
CZ
CRAH_1-CD-11
30 TON
CRAH_1-CD-10
30 TON
CRAH_1-CD-09
30 TON
CRAH_1-CD-07
30 TON
C R
AC
-A
B-
C R
AH
-2
TO
N
S "C
R
AC
-A B-
C R
AH
-2
TO
N S
CRAH_1-CD-03
30 TON
'CRAH AB-10'
CRAH_1-CD-02
30 TON
CRAH_1-CD-01
30 TON
PDU-1-A-17PDU-1-B-16
PD
U
-1 -B
-1
PD
U
-B -1
3PD
U
_1 -B
-0
KV
A
PD
U
_1 -A
-0
KV
A
PD
U
_1 -A
-1
KV
A
PD
U
-1 -A
-1
PD
U
_1 -B
-1
KV
A
PD
U
_1 -A
-1
KV
A
PD
U
_1 -B
-1
KV
A
PD
U
_1 -B
-1
KV
A
PD
U
_1 -B
-1
KV
A
PD
U
_1 -B
-0
KV
A
PD
U
_1 -A
-0
KV
A
PD
U
_1 -B
-0
KV
A
PD
U
_1 -A
-0
KV
A
PD
U
B -1
PDU_1-B-14
125 KVA
PDU_1-A-14
125 KVA
PDU_1-A-03
125 KVA
PDU_1-A-04
125 KVA
PDU_1-B-05
125 KVA
PDU_1-B-06
125 KVA
PDU_1-A-06
125 KVA
PDU_1-A-07
125 KVA
PDU_1-B-07
125 KVA
PDU_1-A-08
125 KVA
PDU_1-B-08
125 KVA
PD
U
_1 -A
-1
KV
A
PD
U
_1 -A
-1
KV
A
PDU_1-B-03
125 KVA
PDU_1-B-04
125 KVA
PDU_1-A-05
125 KVA
PD
U
_1 -B
-1
KV
A
PN
L
LA
-1
DCDCDC
C R
C
AT
_1
-F P-
C R
C
AT
_1
-F P-
C R
C
AT
_1
-F P-
CRAH_1-CD-13
30 TON
DC
DC
DC
CR1
CAT_1-FP-05
CR1 CAT_1-FP-04
P
DC
DC
DC
IR
C
PN
L
IR
C
PN
L
PN
L
D P-
DC
DC
CR1 CAT_1-FP-10
CR1 CAT_1-FP-11
PN
L-
H A
DC A
DC DC DC
C R
C
AT
_1
-F P-
C
R
C
AT
_1 -F
P-
C R
C
AT
_1
-F P-
CDP-A2
480V C
D P-
A C
AB
IN
ET
CRAH_1-CD-04
30 TON
CRAH_1-CD-05
30 TON
C D
P- B
C
AB
IN
ET
CDP-B2
480V
P
DC
DC
DC
C R
AH
_1
-C D
-0
T
O N
A
DCDCDC
CRAH_1-CD-08
30 TON
DCDCDC
A
P
DC
DC
DC
DC
CR1
CACP_1-FP-01
FIRE ALARM
CONTROL
PANEL
CR1
CABP_1-FP-01
FI
R
E
AL
AR
M
PO
W
ER
S
U
PP
LY
C R
AH
_1
-C D
-1
T
O N
A
DC
C R
AH
_1
-C D
-1
T
O N
DC DC DC
C R
2B C
AT
_1
-F P-
C
R 2B
C
AT
_1 -F
P-
C R
2B C
AT
_1
-F P-
BA
S-
L
PA
N
EL
DCDCDC
A
DC
DC
CRAH_1-CD-14
30 TON
DC
DC
DC
A
P
DC
DC
DC
DC
DC
IRC
AO18
1-CD-02
IRC
AS14
1-CD-04
IRC
AX18
1-CD-06
IRC
BB14
1-CD-08
IRC
BB8
1-CD-07
IRC
BG18
1-CD-10
IRC
AX35
1-CD-24
IRC
AS32
1-CD-23
IRC
AO42
1-CD-22
IRC
AO32
1-CD-21
IRC
AI40
1-CD-20
IRC
AI32
1-CD-19
IRC
AE42
1-CD-18
IRC
AE35
1-CD-17
IRC
Z32
1-CD-15
IRC
V41
1-CD-14
IRC
Z42
1-CD-16
CR1
CAT_1-FP-12
PN
L-
ED
P
-A B3
C R
#1 E
PO
PA
N
EL
FI
R
E
AL
AR
M
PA
N
ELVESDA VLP
PANELS
VESDA VLP
PANELS
PN
L-
ED
P
-A B2
CR1 CAT_1-FP-16
CR1 CAT_1-FP-17
CR1 CAT_1-FP-18
CR1
CAT_1-FP-06
C R
C
AT
_1
-F P-
C R
C
AT
_1
-F P-
C R
C
AT
_1
-F P-
C R
C
AT
_1
-F P-
C R
C
AT
_1
-F P-
C R
C
AT
_1
-F P-
FI
R
E
AL
AR
M
C O
N
TR
O L
PA
N
EL
W
AT
ER
L
EA
K
D
ET
EC
TI
O N
VESDA VLP
PANELSPN
L-
ED
P-
AB
C R
2B C
AT
_1
-F P-
C R
2B C
AT
_1
-F P-
C R
2B C
AT
_1
-F P-
FI
R
E
AL
AR
M
C O
N
TR
O L
PA
N
EL
S
FI
R
E
AL
AR
M
PO
W
ER
S
U
PP
LY
CRAH_1-CD-12
30 TON
IRC
AO10
1-CD-01
IRC
AS8
1-CD-03
IRC
AX10
1-CD-05
IRC
BK8
1-CD-11
IRC
BK14
1-CD-12
IRC
BG10
1-CD-09
WDU
1-02
WDU
1-02
PD
U
_1 -A
-1
KV
A
IRC
V34
1-CD-13
VESDA_1-FP-04
VESDA_1-FP-03
VESDA_1-FP-02
CR2A VESDA_1-FP-01
FIRE ALARM
CONTROL
PANELS
CR2A CAT_1-FP-01
CR2A CAT_1-FP-02
CR2A CAT_1-FP-03
CR1 CAT_1-FP-05
CR1 CAT_1-FP-04
C R
AH
_1
-C D
-2
T
O N
1" GAG 1" GAG
1" GAG1" GAG
VAV-4
VA
V-
VA
V-
CR2A CABP_1-FP-01
CR2A CACP_1-FP-01
CABLE TRAY PLAN - ROOM 141
SCALE: 1/8" = 1'-0" 0 4' 8' 16'
KEY PLAN
SCALE: NTS
SHEET
IDENTIFICATION
D
ES
IG
N
B Y:
D R
AW
N
B Y:
SU
BM
IT
TE
D B
Y:
PL
O
T
SC
AL
E:
SI
ZE
AN
SI
D
C H
EC
KE
D B
Y:
PL
O
T D
AT
E:
FI
LE
N
AM
E:
SU
BM
IT
TA
L D
AT
E:
SO
LI
C
IT
AT
IO
N N
O
C O
N
TR
AC
T
N O
FI
LE
N U
M
BE
R
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E:
AP
PR
M
AR
K
D
ES
C R
IP
TI
O N
D
AT
E:
AP
PR
B
C
D
1 2 3 4 5
1 2 3 4 5
Defense Information Systems Agency A Combat Support Agency
A
B
D
C
P.
O
.B O
X
G
R
EE
N W
O O
D V
IL
LA
G E
SE
L
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G
C O
.8
234567 14 13 12 11 10 9 8
* FOR OFFICIAL USE ONLY *
* FOR OFFICIAL USE ONLY *
A
T-101
D
AT
A C
EN
TE
R S
AN
A
N
TO
N
IO
C
AB
LE
T
R
AY
P
LA
N
R O
O M
,1
R
EF
LE
C
TE
D
C
EI
LI
N
G P
LA
N
C R
TE
LE
C
O M
M U
N
IC
AT
IO
N S
D
ES
IG
N
IN
TE
N T
G W
JE
S
AS
S
H O
W N
JE
S
6/ 3/
SA
T_
M D
T -Q
P1
.D W
G
/1
6/
| Sheets and Views |
| SAT A-CP100-A-100 |
| SAT_MD T-QP100-T-101 |
File details come from the government source that posted it. Updated .