Apendix E_WPS_Bidding Documents.pdf

PDF 7 MB Posted

Attached to
OAAA, 2010, 082506, Windsor Readiness Center Backup Battery
Solicitation number
IFB1 OAAA 2027000019 1
Issued by
Arapahoe County, Colorado

About this file

This is a bidding document package for the Windsor Readiness Center Backup Battery project, a state and local contract opportunity involving the Colorado Army National Guard and the Department of Military and Veteran's Affairs. The project encompasses the installation of a battery energy storage system (BESS) and solar photovoltaic (PV) generation system at the Windsor Readiness Center located at 3172 5 Great Western Drive, Windsor, Colorado 80550. The facility is a military training and readiness center with multiple functional areas including classrooms, administrative offices, maintenance facilities, and specialized training spaces. The proposed location for the battery backup system is in Mechanical/Electrical Room B101, as indicated on the floor plan. The bidding documents include detailed product specifications, electrical load calculations, and interconnection plans for integrating renewable energy and backup power capabilities into the existing facility infrastructure.

The technical specifications detail two primary system components: a Sol-Ark 60K-3P-480V commercial hybrid inverter system capable of 60 kilowatts continuous output with three-phase 480-volt capability, and an L3 Series Limitless Lithium battery energy storage system offering multiple configuration options ranging from 40.96 to 61.44 kilowatt-hours of usable capacity. The Sol-Ark inverter features transformerless design, 15-millisecond backup transfer time, integrated four-channel MPPT charge controllers, and modular scalability up to 600 kilowatts with support for DC and AC coupling. The L3 battery system utilizes lithium iron phosphate chemistry with integrated controls, 200-amp transfer relays, and round-trip efficiency of 94 percent. Both systems include ten-year warranties and certifications including UL 1741, UL 1973, and UL 9540 standards. The existing PV generator system was completed as-built in July 2018, with power panels installed in Room C108 due to space constraints, and the documentation references interconnection with the facility's existing electrical infrastructure through multiple distribution panels and automatic transfer switches.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Sol-Ark LLC | Sales: (972) 575-8875 ext. 1, sales@sol-ark.com | Support: (972) 575-8875 ext. 2, support@sol-ark. com | SK150-0015 Rev. 10

Commercial: 60K-3P-480V

Perfect for Large Industrial AC/DC Coupling Capability Modular & Scalable Energy Seamless Backup Power

Simplifies adding energy storage to small commercial buildings.

Enables seamless integration with existing grid-tied PV systems.

Modular and flexible design allows for easy installation and expansion.

Helps meet your corporate renewable energy goals and decarbonization efforts.

Native 277/480V 3P output with Wye or Delta options simplifies installation, removing the need for external transformers.

Allows for efficient DC coupling using the integrated 4x channel MPPT charge controller.

Accommodates a range of system sizes with outputs starting from 60kW going to 600kW.

Blazing fast 15ms transfer time with 200A grid relay allows for business continuity during grid outages.

Commercial: 60K-3P-480V

Sol-Ark Commercial Energy Solutions

Mounting cleat for easy installation

2x Integrated locking PV disconnect

WiFi or Ethernet monitoring via MySolArk

Outdoor-rated to NEMA 3R

Sol-Ark LLC | Sales: (972) 575-8875 ext. 1, sales@sol-ark.com | Support: (972) 575-8875 ext. 2, support@sol-ark. com | SK150-0015 Rev. 10

DATASHEET 60K-480V SKU: 60K-3P-480V

60K-3P-480V C&I Hybrid Inverter

Input Data (PV)

Max. Allowed PV Power (STC) 78,000W

MPPT Voltage Range 150-850V

Startup Voltage 180V

Max. Input Voltage 1 1,000V

Max. operating input current per MPPT 36A

Max. short circuit current per MPPT 55A

No. of MPP Trackers 4

No. of PV Strings per MPPT 2

Max. AC Coupled Input 60,000W

Output Data (AC)

Nominal AC Voltage (3Φ) 2 277/480V (4-wire Wye) or 480V (3-wire Delta)

Grid Frequency 50 / 60Hz

Real Power, max continuous (3Φ) 60,000W

Max. Output Current 72.3A

Peak Apparent Power (10s, off-grid, 3Φ) 90,000VA

Max. Grid Passthrough Current (10min) 200A

Continuous Grid Passthrough Current 180A

Power Factor Output Range +/- 0.8 adjustable

Backup Transfer Time 15ms (adjustable)

CEC Efficiency 96.5%

Max Efficiency 97.5%

Design (DC to AC) Transformerless DC

Stackable Up to 10 in parallel

Battery Input Data (DC)

Supported Battery Chemistry Lithium-ion

No. of Battery Inputs 2

Battery Input Terminal Rating 50A

Nominal DC Voltage ≥ 600V

Operating Voltage Range 160 - 700V

Battery Capacity Range 50 — 9900Ah

Max. Battery Charge / Discharge Current 100A (50A per input)

Charge Controller Type CC/CV - BMS Controlled

Grid to Battery Charging Efficiency 96.0%

Automatic Generator Start (AGS) 2 Wire Start - Integrated

BMS Communication 3 CAN (Controller Area Network)

General Data

Dimensions (H x W x D) 894 x 528 x 295 mm (35.2 x 20.8 x 11.6 in)

Weight 80 Kg / 176 lb.

Enclosure IP65 / NEMA 3R

Operating Temperature -40 – 60°C, >45°C Derating

Operating Altitude 4 2000 m (6561 ft)

Noise Level @ 1m < 30 dB @ 25°C (77°F)

Idle Consumption - No Load 60W

Communication and Monitoring Wi-Fi & LAN Hardware Included

Warranty 10 Years

Category

Certifications and Listings (Grid Support Interactive Inverter)

UL 1741-2021 (UL1741SB), CSA C22.2 No 107.1-16, IEEE 1547-2018 & 1547a-2020 & 1547.1-2020 (SRD V2.0), UL 1741 CRD-PCS, UL1699B, CEC, SGIP, CSIP

PV DC Disconnect Switch — NEC 240.15 Integrated

Ground Fault Detection — NEC 690.5 Integrated

PV Rapid Shutdown Control — NEC 690.12 Integrated

PV Arc Fault Detection — NEC 690.11 Integrated

PV Input Lightning Protection Integrated

PV String Input Reverse Polarity Protection Integrated

Surge Protection DC Type II / AC Type III

1 See the Installation Manual for details on sizing array strings. Highest input voltage is based on the open-circuit voltage of the array at minimum design temperature.

2 Does not support corner grounded delta, high leg delta, or 240V delta systems. Consult the installation manual or solark.com for details.

3 Active BMS communication is required for all lithium batteries. See solark.com for list of compatible battery partners.

4 Derating occurs above 2000 m (6561 ft).

Sol-Ark reserves the right to modify specifications at any time, and without prior notice. See sol-ark.com for the latest information.

https://www.sol-ark.com/solar-installers/knowledge-hub/ https://www.sol-ark.com/solar-installers/battery-partners/ https://www.sol-ark.com/solar-installers/knowledge-hub/

Sol-Ark LLC | Sales: (972) 575-8875 ext. 1, sales@sol-ark.com | Support: (972) 575-8875 ext. 2, support@sol-ark.com PS-00020 Rev. 12

L3 BESS: 208V Outdoor and Indoor

Modular Solutions Efficient and Flexible Scalable and Cost Effective Innovative

L3 HV-40: Stack up to 10 inverters / 160 battery cabinets for 300kWac / 6.4MWh

Increase business uptime and reliability with industry leading backup power.

Maximize ROI with industry-leading cost per kWh.

Integrated controls, 200A transfer relays, AC and DC coupling.

L3 HVR-60: Stack up to 6 inverters / 36 battery cabinets for 180kWac / 2.2MWh

Reduce utility demand charges with integrated peak shaving control.

Reduce wiring costs and integrate electric vehicle charging stations using the GEN port.

Reduce installation costs with built-in module and cabinet fire suppression.

Sell excess energy back to the grid or participate in DER programs.

Combine renewable energy sources.

Integrated 4-channel MPPTs allow maximum charging efficiency.

Outdoor BESS IP55 rated

Indoor BESS IP20 rated

Sol-Ark LLC | Sales: (972) 575-8875 ext. 1, sales@sol-ark.com | Support: (972) 575-8875 ext. 2, support@sol-ark.com PS-00020 Rev 12

| L3 Series Limitless Lithium Battery Energy Storage System

208V Options Battery Energy Storage System Outdoor Indoor Battery Model Name:

ESS Model Name:

Sol-Ark Product SKU:

L3 HVR-60

L3 HVR-60KWH-30K

L3-HVR-60KWH

L3 HV-40

L3 HV-40KWH-30K

L3-HV-40KWH

System Data

Compatible Inverter Model Sol-Ark 30K-3P-208V

Cell Chemistry Lithium Iron Phosphate

Nameplate Energy Capacity (DC) 61.44 kWh 40.96 kWh

Usable Energy Capacity (DC) 1 55.30 kWh 36.86 kWh

Built-In DC Disconnect Rating 200A

Internal Fuse Rating 160A

Max. # Battery Units Per Inverter 6 16

Max. # Inverters in Parallel 6 10

Recommend Depth of Discharge 90%

Roundtrip Efficiency Charge/Discharge (DC) 94% (25C, 0.5C)

System Nominal Voltage (DC) 307V 410V

System Operating Voltage (DC) 294V — 336V 392V — 448V

Battery Pack Internal Configuration 6s2p 8s1p

Charge/Discharge Current (DC) 2

• Recommend 100A 50A

• Max. Continuous 100A

• Peak Discharge (60 sec @ 25ºC) 125A

Battery Max. Continuous Charge/Discharge Power (DC) 61.44kW 40.96kW

ESS Max. Continuous Charge/Discharge Power (AC) 30kW

Fault Current Contribution per Battery 4,200A / 1.47ms

Mechanical Specifications

Product Dimensions (WxDxH) 76x107x226 cm (30x42x89 in) 58x58x163 cm (23x23x64 in)

Net Weight 950 kg (2,095 lbs) 628 kg (1,384 lbs)

Mounting Type Outdoor Enclosure Freestanding Rack Mount

Material and Finish Steel — Corrosion Resistant Powder Coat Steel — Powder Coated

Operating Temperature3 and Humidity -20°C — 50°C (-4°F — 122°F) — 5%—85% RH 4°C — 43°C (40°F — 110°F) — 5%—85% RH

Operating Altitude 4 3000m (9,843 ft)

Storage Conditions 5 -4ºF — 95ºF — Up to 85% RH (non-condensing) and State of Charge (SOC) 30%

Ingress Rating IP55 (NEMA 3R) IP20 (NEMA 1)

Noise Level @ 1m 75 dBA at 30°C (86°F) < 40 dBA at 30°C (86°F)

Seismic Mounting Up to Category F

Communication Ports CAN2.0/RS485

Battery Module Specifications

Battery Module Nominal Energy Capacity 5.12kWh

Battery Module Nominal Voltage and Capacity 51.2V / 100Ah

Terminal Type Amphenol SurLok – Push Lock Connector

Warranty and Certification

Performance Warranty 6 10 years or 196MWh Throughput 10 years or 130MWh Throughput

Product Warranty 10 Years

Certifications UL1973, UL9540, UL9540a, UN38.3, FCC, Prop 65

1. DC usable energy, test conditions: 90% DOD, 0.3C charge and discharge at 25ºC. System usable energy may vary due to system configuration parameters.

2. Output current is affected by battery temperature and SOC.

3. Temperature is based on the average cell temperature measured by the BMS. Charging is disabled below 0°C (32ºF). Derating occurs above 45°C (113ºF). Contact Sol-Ark for outdoor sites.

4. Battery will operate at a maximum 1C charge/discharge up to 2000m, above 2000m maximum output is derated to 0.8C, contact Sol-Ark for details.

5. Storage temperature of the battery with no charge or discharge

6. EOL (End of Life) 70% retained capacity. See L3 Series warranty document for details.

Sol-Ark has a policy of continuous improvement and reserves the right to modify its specifications at any time and without prior notice. Please visit sol-ark.com for the latest information.

143014301430

DD

HHH

VENT HOODS

W/ DAMPER CONTROL

OPTIONAL

D

C C C

C H

D D

D D

D C

C

D

D

C

G G

G

D

C

D

DHIN

HOUT

D

CWICWO

H

C

FD

FD

A201

A201 D1

A1

ASSEMBLY HALL

B105

LOBBY / MAIN HALL

C117

KITCHEN

C104

CLASSROOM

C114

MECH

C107

MDF

C108 RECRUITING

C113

LEARNING CENTER

C109

UNIT STORAGE

B107

CORRIDOR

B106

VAULT

B103

VAULT

B102

DIST.

B104

TABLE & CHAIR

STOR.

C105

CONTROLLED

WASTE

A103

LOCKER ROOM

B100

MECH/ELEC

B101

MAINT. & STOR.

B111

SUPPLY OFFICE

B110

UNIT LEVEL

MAINTENANCE

TRAINING

A100

SUPPLY

A104

FLAM MTLS.

A102

OFFICE / LIBRARY

A110

TOOLS

A108

CORRIDOR

A107

AUDIO/VISUAL

STORAGE

C112

TRAINING AID

STORAGE

C115

READINESS NCO

C134

VESTIBULE

C116

ELEC

B108

VESTIBULE

C118

MEN'S

C119

CONFERENCE

C129

FAMILY READINESS

C130 ADMIN NCO

C132

1ST SGT

C136

COMMANDER

C137

ADMINISTRATION

C133RECY. / PRINT

C131

BREAK

C128

CLASSROOM

C111

JAN.

C122

SCULLERY

C100

OFFICE

C101

JAN

C102

DRY STORAGE

C103

A201 C1

B1 A301

A1 A302

A1 A302

B3 A302

B3 A302

D4 A302

D4 A302

D2 A302

D1 A302

B1 A302

B2 A302

A5 A321

WASH BAY

D1 A301

C4 A301

C4 A301

EXECUTIVE

OFFICER

C135

A1 A301

A1

A301JAN

A109

A201 B1

A2 A322

A3 A323

A2 A324

A2 A325

A3 A325

A203 A1

ELEC

C106

A203 C3

CORRIDOR

C127

2 3 4 6

A

B

C

F

E

G

H

J

K

5 12

15 16

8 9 11101

STORAGE

C104A

FITNESS

C126

WOMEN'S

C124

2'

- 4

4"

4"

4"

4'

- 0

2'

- 4

9" 20' - 9" 40' - 8" 34' - 8" 53' - 8" 29' - 4" 56' - 8" 33' - 8" 36' - 2" 20' - 4" 9' - 0" 28' - 0" 1' - 6"

21' - 6" 75' - 4" 139' - 8" 128' - 8"

365' - 2"

2'

- 8

8"

4"

4"

4"

4"

4"

21' - 6" 40' - 8" 34' - 8" 126' - 1 1/4"

236' - 6"

D

4"

122' - 8"

4"

8"

8"

8"

21' - 0" 34' - 4"

10' - 4" 34' - 4"

19' - 8"

CONTRACTOR TO DETERMINE

SIDEWALK/LANDSCAPE LOCATIONS

FROM CAD FILE, TYP.

B1 A301

B1 A301

B3 A302

B3 A302

EQUIPMENT

PLATFORM

B200

A

B

P

LO

T

D A

TE

A

P R

O

JE

C T

IN

FO

R M

A

TI

O N

S H

EE

T

IN

FO

R M

A

TI

O N

P R

O

JE

C T

P H

A S

E A

R C

H

IT

EC

T

S

EA

L

REVISIONS

ISSUE DATE:

CHECKED BY:

DRAWN BY:

RB+B PN:

Architects, Inc.

C O

N S

U

LT

A N

T

T - 970.484.0117 F - 970.484.0264

315 East Mountain Ave Suite 100 Fort Collins, CO 80524-2913

© 2009 www.rbbarchitects.com

B

C

D

A

B

C

D

1 2 3 4 5

2 3 4

7/

/2

3:

0 0 :1

PM

G

R

EA

T W

ES

TE

R N

D R

IV

E W

IN

D

S O

R

C O

A101

LEVEL ONE FLOOR PLAN

W

IN

D S

O R

R

EA

D

IN

ES

S

C

EN

TE

R

C O

LO

R A D

O A

R M

Y N

A

TI

O N

A L

G U

A R D

DY/KF

ESM

CONSTRUCTION

DOCUMENTS

July 20, 2011

1/16" = 1'-0" A1

FLOOR PLAN

N

EQUIPMENT PLATFORM

NO DESCRIPTION DATE

VOL. 1 - 97 of 151

Proposed Location of Battery Backup System

1633706057.NFG

Text Box Mech/Elec Room B101

1633706057.NFG

Line

Department of Military and Veteran's Affairs

Colorado Army National Guard Windsor

Readiness Center PV-Generator System

PN080580

Curtis Hansen

AS BUILT 7/2018

UP

Curtis Hansen

*PANELS SPH AND SPL INSTALLED IN

RM C108 DUE TO SPACE LIMITATIONS

UP

Panel SPH

Curtis Hansen Panel SPL

Curtis Hansen

XFMR

TLSB &

TSPL

Curtis Hansen

Curtis Hansen

Curtis Hansen

Curtis Hansen

Curtis Hansen

Curtis Hansen

Curtis Hansen

Curtis Hansen

Curtis Hansen

Curtis Hansen

Curtis Hansen

Curtis Hansen

Curtis Hansen

Curtis Hansen

Curtis Hansen

Curtis Hansen

Curtis Hansen

Curtis Hansen

Curtis Hansen

Curtis Hansen

Curtis Hansen

Curtis Hansen

Curtis Hansen

SPL

Curtis Hansen

Curtis Hansen

Curtis Hansen

SPH

Curtis Hansen

Curtis Hansen

Curtis Hansen

Curtis Hansen

Curtis Hansen

Curtis Hansen

Curtis Hansen

Curtis Hansen

Curtis Hansen

Curtis Hansen

Curtis Hansen

SPARE JUNCTION BOX AND

CONDUIT FROM MSB TO SPH

FEEDER CONDUIT FROM HE TO SPH

Generator status and output ATS 1 kW, kWh, Amps ATS 2 kW, kWh, Amps smart panel status (2) smart panel load (2) GPM controller failure status GPM inverter limiting status

Curtis Hansen

Curtis Hansen

Curtis Hansen

Curtis Hansen

Curtis Hansen x

Curtis Hansen x

Curtis Hansen x

Curtis Hansen x

Curtis Hansen x

Curtis Hansen x

Curtis Hansen *CT’s ARE LOCATED ON GENERATOR OUTPUT CONDUCTORS

**METER MOUNTED TO ATS ‘HE’

SPD

10,000

DESCRIPTION

C112/C113 Rcpt (New)

Spare

Spare

Spare

Spare

Spare

Spare

Spare

Spare

Space

Space

Space

Space

Space

Space

TOTAL

TOTAL

LOAD

DESIGN

AMP

AIC

/ 208

L

VOLT

A MAIN CB

R

M

A

E

T|S|O

M|A|E|H

KVA

AMPS

PHASE

PANEL

GROUND BUS

100% NEUTRAL BUS

PHASE

A

B

C

A

B

C

A

B

C

A

B

C

A

B

C

A

B

C

A

B

C

LOADS IN

VOLT-AMPERES

50.0

SPL

KVA

AMPS

AMPS

L

WIRE SERVICE

R

CONNECTED

DESIGN

DEMAND

SPARE

M

A

E

SURFACE MOUNTED

T|S|O

M|A|E|H DESCRIPTION

Spare

Spare

Spare

Spare

Spare

Space

Space

Space

Space

Space

TOTAL

KVA

KVA

KVA

KVA

SPD

14,000

DESCRIPTION

Area A Exterior Ltg

Area B Exterior Ltg

Area C Exterior Ltg

Area A Em Ltg

Area C Em Ltg

Spare

Spare

Spare

Spare

Spare

Spare

Spare

Spare

Spare

Space

Space

Space

Space

Space

Space

TOTAL

TOTAL

LOAD

DESIGN

SPARE

AMP

AIC

/ 480

L

VOLT

MAIN LUGS ONLY

R

16.0

19.3

M

A

E

T|S|O

M|A|E|H

KVA

AMPS

PHASE

D.F.

PANEL

GROUND BUS

100% NEUTRAL BUS

PHASE

A

B

C

A

B

C

A

B

C

A

B

C

A

B

C

A

B

C

A

B

C

LOADS IN

VOLT-AMPERES

18.7

22.5

60.0

37.5

HE

KVA

AMPS

AMPS

AMPS

L

WIRE SERVICE

R

CONNECTED

DESIGN

DEMAND

SPARE

S

S

S

M

A

E

SURFACE MOUNTED

T|S|O

M|A|E|H

2960.0

3653.0

1000.0

DESCRIPTION

TRANSFORMER

TE

Area B Em Ltg

PV CONNECTION BRKR

Spare

Spare

Spare

Spare

Spare

Spare

Spare

Spare

Space

Space

Space

TOTAL

18.7

49.9

18.7

31.2

KVA

KVA

KVA

KVA

10,000

DESCRIPTION

FACP

C116 Door Locks

LCPA

Spare

Spare

Spare

Spare

Spare

TOTAL

TOTAL

LOAD

DESIGN

SPARE

AMP

AIC

/ 208

L

VOLT

A MAIN CB

R

5.0

8.4

E

E

E

M

A

E

T|S|O

M|A|E|H

KVA

AMPS

PHASE

PANEL

GROUND BUS

100% NEUTRAL BUS

PHASE

A

B

C

A

B

C

A

B

C

A

B

C

LOADS IN

VOLT-AMPERES

5.0

13.9

50.0

36.1

LE

KVA

AMPS

AMPS

AMPS

L

WIRE SERVICE

R

CONNECTED

DESIGN

DEMAND

SPARE

E

E

M

A

E

SURFACE MOUNTED

T|S|O

M|A|E|H

DESCRIPTION

MNS Power Supply

B104 - Door Locks

LCPB

Spare

Spare

Spare

Spare

Spare

Spare

Spare

Spare

Spare

TOTAL

5.0

18.0

5.0

13.0

KVA

KVA

KVA

KVA

C112/C113 Rcpt (New)

C112/C113 Rcpt (New)

C112/C113 Rcpt (New)

Spare

Spare

Spare

Space

Spare

Spare

Spare

Spare

Spare

Spare

Spare

Spare

Spare

Spare

SPD

14,000

DESCRIPTION

C111/C114 Lighting

Spare

Spare

Spare

Spare

Spare

Spare

Spare

Spare

Space

Space

Space

Space

Space

Space

TOTAL

TOTAL

LOAD

DESIGN

AMP

AIC

/ 480

L

VOLT

A MAIN CB

R

10.2

M

A

E

T|S|O

M|A|E|H

KVA

AMPS

PHASE

PANEL

GROUND BUS

100% NEUTRAL BUS

PHASE

A

B

C

A

B

C

A

B

C

A

B

C

A

B

C

A

B

C

A

B

C

LOADS IN

VOLT-AMPERES

60.0

SPH

KVA

AMPS

AMPS

L

WIRE SERVICE

R

CONNECTED

DESIGN

DEMAND

SPARE

M

A

E

SURFACE MOUNTED

T|S|O

M|A|E|H DESCRIPTION

Spare

Spare

Spare

Spare

Spare

Space

Space

TOTAL

KVA

KVA

KVA

KVA

Corridor Lighting

Restroom Lighting

Spare

Spare

Spare

Space

XFMR

Spare

Spare

Spare

Spare

Spare

0 2000

C111/C114 Lighting(Note 1)

NOTES:

1. CONNECT TO SPARE BREAKER IN PANEL.

NOTES:

1. CONNECT TO SPARE BREAKER IN PANEL.

C112/C113 Rcpt (New)

C112/C113 Rcpt (New)

C112/C113 Rcpt (New)

C112/C113 Rcpt (New)

(Note 2)

2. NEW BREAKER IN SPACE NOTED. THIS BREAKER SHALL FEED PANEL SPH FOR SMART PANEL ALTERNATE.

Spare

Spare

Spare

PV CONNECTION BRKR

Spare

Spare

Spare

Curtis Hansen

Curtis Hansen

SPARE BREAKERS FOR CIRCUITS 9 & 11 PROGRAMMED TO ‘TIER 2’

Curtis Hansen

Curtis Hansen

Curtis Hansen

FEED TO PANEL SPH

SPARE

60K-3P-480V_Datasheet_Rev_10_31July2026
L3_208V_Rev12_Combined_Datasheet_8Aug2025
Windsor Floor Plan- marked with BESS location
Windsor PV Generator Systems As Built Dwgs
150450-E2.01-Power Plan-E0.1
150450-E2.01-Power Plan-E0.2
150450-E2.01-Power Plan-E1.1
150450-E2.01-Power Plan-E2.1
150450-E2.01-Power Plan-E2.2
150450-E2.01-Power Plan-E3.1
150450-E2.01-Power Plan-E3.2
Windsor Stamped PV Drawings DG 8-22-2012
DESTINATION1_0000002834
DESTINATION1_0000002828
DESTINATION1_0000002829
DESTINATION1_0000002830
DESTINATION1_0000002831
DESTINATION1_0000002832
DESTINATION1_0000002833

File details come from the government source that posted it. Updated .