100_PCT_Design_REV_1.pdf
PDF 28 MB Posted
- Attached to
- Groveland Hotshot Garage Construction Federal contract opportunity
- Solicitation number
- AG-9JGP-S-16-0029
About this file
Revision 1
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 13_28_10_Asbestos_Remediation.pdf | ||
| Groveland_HS_Civil--_Final_-_C_7.1.pdf | ||
| Amend_003_Hotshot_Garage_SF30.doc | DOC document | |
| 02_26_26_lead_remediation.pdf | ||
| Groveland_Building_2205_Environmental.pdf | ||
| Hotshots_Geotechnical_Report.pdf | ||
| Site_Visit_2-10-16_Engine_Garage.pdf | ||
| Amend_002_Hotshot_Garage_SF30.doc | DOC document | |
| 07160_Manhole_Sealing.doc | DOC document | |
| 100_PCT_Design.pdf | ||
| Drawing.pdf | ||
| Catalog_Cuts.pdf | ||
| 9._PAL_Fire_Plan_Aug_2012.doc | DOC document | |
| Project_Specifications.pdf | ||
| Wage_Determination.docx | DOCX document | |
| Door_Schedule.docx | DOCX document | |
| Solicitation.doc | DOC document | |
| Wage_Determination.docx | DOCX document | |
| Solicitation 1442 | — | |
| 9. PAL Fire Plan Aug 2012.doc | DOC document | |
| 226169.pdf | ||
| Solicitation.zip | ZIP file |
Show all 22
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
GENERAL NOTES SYMBOLS SHEET NO.
l. ALL WORK AND MATERIALS SHALL BE IN ACCORDANCE WITH THE APPLICABLE RULES AND REGULATIONS OF FEDERAL, STATE AND/OR LOCAL CODES, LAWS, ORDINANCES, STATUTES AND REGULATIONS.
NOTHING IN THE DRAWINGS IS TO BE CONSTRUED AS REQUIRING OR PE~MITIING WORK CONTRARY TO
THESE APPLICABLE RULES, REGULATIONS AND CODES.
2. THESE NOTES ARE INTENDED AS A GUIDE TO THE CONSTRUCTION REQUl~tMENTS ESTABLISHED FOR THIS PROJECT. NO CONTRACTOR SHOULD A TIEMPT TO DESIGN, BID, OR CONSTRUCT ANY PORTION OF THE
WORK HEREIN WITHOUT FULL UNDERSTANDING OF THE DESIGN INTENT AND APPLICABLE CODE
REQUIREMENTS. THE CONTRACTOR SHOULD OBTAIN CLARIFICATION FROM THE CONTRACTING OFFICER
IF HE OR SHE IS UNCERTAIN OF DESIGN INTENT.
3. THE DESIGN PRESENTED ON THESE DRAWINGS ESTABLISHES THE GENERAL ARCHITECTURAL REQUIREMENTS
FOR THE PROJECT. IT DOES NOT PRESENT ALL DETAILS REQUIRED FOR CONSTRUCTION.
4. THE DRAWINGS INDICATE LOCATION, DIMENSIONS, AND TYPICAL DETAILS OF CONSTRUCTION. FEATURES OF CONSTRUCTION SHOWN ARE TYPICAL AND APPLY GENERALLY FOR SIMILAR CONDITIONS. THE DRAWINGS DO NOT ILLUSTRATE EVERY CONDITION. IN THE EVENT THAT CERTAIN FEATURES ARE NOT FULLY SHOWN ON THE DRAWINGS OR CALLED FOR IN THE SPECIFICATIONS THEIR CONSTRUCTION SHALL BE (A)
OF THE SAME CHARACTER AS SHOWN FOR SIMILAR CONDITIONS; OR (BJ IN ACCORD WITH
CONVENTIONAL PRACTICES OF THE IBC; OR (C) AS CLARIFIED BY THE C.O. WHERE DISCREPANCIES
OCCUR, THEY SHALL BE REPORTED TO THE CONTRACTING OFFICER FOR RESOLUTION.
5. NO ONE DRAWING OR SPECIFICATION SECTION SHALL "GOVERN". CONTRACTOR SHALL CORRELATE
WORK AMONG CONSTRUCTION DRAWINGS, SPECIFICATIONS AND SHOP DRAWINGS AND
SPECIFICATIONS. CONTRACTOR SHALL ALSO CORRELATE WORK AMONG DRAWINGS OF DIFFERENT
SCALES WITHIN EACH SECTION. IT IS THE EXPLICIT AND SPECIFIC RESPONSIBILITY OF THE CONTRACTOR TO EXAMINE THE CONTRACT DOCUMENTS IN THEIR ENTIRETY, REPORT ALL DISCREPANCIES ENCOUNTERED THEREIN TO THE CONTRACTING OFFICER AND AWAIT RESOLUTION BEFORE PROCEEDING WITH ANY WORK
AFFECTED BY SUCH DISCREPANCIES.
6. UNLESS SHOWN OTHERWISE, DETAILS SHOWN AS 'TYPICAL" APPLY WHEREVER APPROPRIATE. SPECIFIC DETAILS TAKE PRECEDENCE OVER 'TYPICAL" DETAILS. SPECIFIC NOTES ON DRAWINGS TAKE PRECEDENCE
OVER GENERAL NOTES.
7. THE CONTRACTOR SHALL CAREFULLY STUDY AND COMPARE THE CONTRACT DOCUMENTS AS TO ALL
LAYOUTS, DIMENSIONS, AND ELEVATIONS AND SHALL AT ONCE REPORT DISCOVERED ERRORS,
INCONSISTENCIES, OR OMISSIONS TO THE CONTRACTING OFFICER. IF THE CONTRACTOR PERFORMS ANY CONSTRUCTION ACTIVITY KNOWING IT INVOLVES A RECOGNIZED ERROR, INCONSISTENCY OR OMISSION
IN THE CONTRACT DOCUMENTS WITHOUT SUCH NOTICE, THE CONTRACTOR SHALL ASSUME
RESPONSIBILITY FOR SUCH PERFORMANCE AND SHALL BEAR THE COSTS FOR CORRECTION.
8. DO NOT SCALE THE DRAWINGS. LAY OUT WORK FOLLOWING WRITIEN DIMENSIONS. IF WRITIEN DIMENSIONS ARE LACKING, NOTIFY THE CONTRACTING OFFICER AT ONCE. WHERE DISCREPANCIES
OCCUR, THEY SHALL BE REPORTED TO THE C.O. FOR RESOLUTION.
9. ANY SITE OR BUILDING AREAS UNAFFECTED BY THIS WORK SHALL BE PROTECTED FROM ANY DAMAGE CAUSED BY THIS WORK. ANY DAMAGE TO EXISTING STRUCTURES OR BUILDING ELEMENTS SO CALLED
SHALL BE THE FINANCIAL RESPONSIBILITY OF THE CONTRACTOR.
l 0. ANY WASTE AND REFUSE CAUSED BY THIS WORK SHALL BE REMOVED FROM THE PREMISES AND
DISPOSED OF BY EACH CONTRACTOR IN A LEGAL MANNER.
l l. BROOM CLEAN CONSTRUCTION PREMISES AT THE END OF EACH DAY & FINAL CLEANING TO INCLUDE
WINDOWS AT THE END OF THE JOB.
ABBREVIATIONS
or
AND
ANGLE
AT
CENTERLINE
DEGREES
DIAMETER OR ROUND
POUND OR NUMBER
PROPERTY LINE
IE) EXISTING
A.B. ANCHOR BOLT
AC AIR CONDITIONING
A.C. ASPHALTIC CONCRETE
ACCESS. ACCESSIBLE
ACOUST. ACOUSTICAL
A.A. AREA DRAIN
ADJ. ADJUSTIBLE
c.o.
COL.
CONC.
C.M.U.
CASED OPENING or
CLEAN OUT
COLUMN
CONCRETE
CONCRETE MASONRY UNIT
CONN. CONNECTION
CONSTR. CONSTRUCTION
CONT. CONTINUOUS
CORR. CORRIDOR
CTSK. COUNTERSINK
CNTR. COUNTER
CTR. CENTER
CPT CARPET
DBL. DOUBLE
DEPT. DEPARTMENT
B.F. BOITLE FILLER
ERA
EWA
FA
F.B.
F.D.
FON.
F.A.
FIN.
FL.
FLASH.
F.0.C.
F.0.F.
F.O.S.
FRP.
F.S.
EXTERIOR ROOF ASSEMBLY INT.
EXTERIOR WALL ASSEMBLY
FIRE ALARM
FLAT BAR
FLOOR DRAIN
FOUNDATION
FIRE EXTINGUISHER
FINISH
FLOOR
FLASHING
FACE OF CONCRETE
FACE OF FINISH
FACE OF STUDS
FIREPROOF
FULL SIZE
JAN.
JT.
JST.
KIT.
LAM.
LAV
LKR.
LT.
INTERIOR
JANITOR
JOINT
JOIST
KITCHEN
LAMINATE
LAVATORY
LOCKER
LIGHT
MAXIMUM
MECHANICAL
MEMBRANE
METAL
MANUFACTURER
MINIMUM
AGGR. AGGREGATE
Al. ALUMINUM
APPROX./= APPROXIMATE
ARCH. ARCHITECTURAL
DET./DTL. DETAIL
DIA. DIAMETER
DIM. DIMENSION
DISP. DISPENSER
FT.
FTG.
FURR.
FUT.
G.I.
GA.
GALV.
G.B.
FOOT OR FEET
FOOTING
FURRING
FUTURE
GALVANIZED IRON
MAX.
MECH.
MEMB.
MET.
MFR.
MIN.
MIR.
MISC.
M.O.
MND.
MUL.
MIRROR
MISCELLANEOUS
MASONRY OPENING
MOUNTED
A.F.F. ABOVE FINISH FLOOR ON. DOWN
D.O. DOOR OPENING
DR. DOOR
BD. BOARD
BITUM. BITUMINOUS
BLDG. BUILDING
BLK. BLOCK
BLKG. BLOCKING
BM. BEAM
BOT. BOTTOM
DWR. DRAWER GL.
D.S. DOWNSPOUT GND.
DWG. DRAWING GR.
D.W. DISHWASHER GRD. P
GYP.
E. EXISTING
B.U.R. BUILT~UP ROOFING E.J. EXPANSION JOINT H.B.
CAB. CABINET EL. ELEVATION H.C.
C.A. CATCH BASIN
CEM. CEMENT
CER. CERAMIC
ELEC. ELECTRICAL HOWD.
ELEV. ELEVATOR HOWE.
EMER. EMERGENCY HVAC
C.I. CAST IRON
C.J. CONTROL JOINT
C.G. CORNER GUARD
CLG. CEILING
ENCL. ENCLOSURE
E.P. ELECTRICAL PANEL BOARD HGT.
EQ. EQUAL H.M.
EQPT. EQUIPMENT HOR.
CLKG. CAULKING EXPO. EXPOSED HR.
CLO. CLOSET EXP. EXPANSION l.D.
CLR. CLEAR EXT. EXTERIOR INSUL.
PROJECT NUMBER CHECKED BY NO. DATE REVISIONS
2407.01 MM
DESIGNED BY CHECKED BY
SL -
DRAWN BY DATE
SL 11-12-2015
GAUGE
GALVANIZED
GRAB BAR
GLASS
GROUND
GRADE
GROUND PULLBOX
GYPSUM
HOSE BIB
HOLLOW CORE
HARDWOOD
HARDWARE
HEATING, VENTILATING,
AND AIR CONDITIONING
HEIGHT
HOLLOW METAL
HORIZONTAL
HOUR
INSIDE DIAMETER
INSULATION
N.
N.l.C.
NO. or#
NOM.
N.T.S.
o.u.
OBS.
o.c.
0.D.
OPNG.
OPP.
O.H.
OJ
0.P.C.I.
0.P.0.1.
PH
MULLION
NEW
NOT IN CONTRACT
NUMBER
NOMINAL
NOT TO SCALE
OVERALL
OBSCURE
ON CENTER
OUTSIDE DIAMETER IDIM.)
OPENING
OPPOSITE
OPPOSITE HAND
OVER
OWNER PROVIDED.
CONTRACTOR INSTALLED
OWNER PROVIDED,
OWNER INSTALLED
PANIC HARDWARE
NO. DATE
l TODD 2 CO.l 3 Cl.O
ROOM NAME
I RM# I
ROOM NAME AND NUMBER REVISION MARK ASSEMBLY TYPE MARK STRUCTURAL GRID LINE MARK~
NUMBERS IN VERTICAL DIRECTION.
LETTERS IN HORIZONTAL DIRECTION
4 C2.0
NORTH ARROW
NOTE
DOOR MARK
0 WINDOW MARK
GU_
DATUM POINT MARK
SECTION CUT MARK
DETAIL MARK
EXTERIOR ELEVATION MARK
ASSEMBLY DESCRIPTION/LO!;;;/l,TION:
EWA- EXTERIOR WALL ASSEMBLY
[ xxx:iC ERA - EXTERIOR ROOF ASSEMBLY
ASSEMBLY TYPE:
REFER TO SHEET El/A300
PARTITION TYPE MARK
PARTITION TYPE: REFER TO
SHEET ASOO FOR PARTITION TYPES.
SPECIFICATION KEY NOTE
A
DOB
c
INTERIOR WALL PLAN
DESIGNATION FOR FINISH
SCHEDULE AND INTERIOR
ELEVATIONS
5 C3.0 6 C4.0 7 C5.0 8 C6.0 9 C7.0 l 0 C7. l l l C7.2 12 C7.3 13 AOOl 14 A002 15 A003 16 Al OD 17 Al30 18 Al50 19 Al60 20 A200 21 A20l 22 A300 23 A30l 24 A310 25 A320 26 A32l 27 A400 28 A40l 29 A402 30 A500 31 A50l 32 A510 33 A600 34 A60l 35 A700 36 Sl 37 S2 38 S3 39 S4 40 S5 41 S6 42 Pl.O 43 P2.0 44 P3.0 45 P4.0
46 MO.O
47 M l.O 48 M2.0 49 M2. l
50 M3.0 GROVELAND HOTSHOTS OFFICE AND GARAGE
51 T24.0 52 T24. l
NOTE: THE DESIGN AND DRAWINGS FOR THIS BUILDING ARE SPECIFICALLY FOR THE GROVELAND FIRE STATION AND SHALL NOT BE USED FOR ANY OTHER SITE WITHOUT WRITIEN AUTHORIZATION FROM THE R-5 REGIONAL ARCHITECT. THE DESIGN IS SITE SPECIFIC. MODIFICATIONS TO THESE DRAWINGS SHALL BE COORDINATED WITH THE R-5 REGIONAL
ARCHITECTAND/OR ARCHITECT OF RECORD.
53 EOOl 54 E002 55 ElOl
PL
P.LAM.
PRECST.
PLYWD.
PR.
PT.
P.T.
PTO.
RAD.
R.C.P.
R.D.
REF.
REINF.
REQ.
RESIL.
RM.
R.O.
R.W.L.
s.
s.c.
SCH ED.
SECT.
SH.
SHR.
SHT.
S.M.
SIM.
SPEC.
SQ.
S.G.
S.STL.
STA.
STL.
STOR.
STRL.
SUSP.
REVISIONS
PLATE
PLASTIC LAMINATE
PLASTER
PLYWOOD
PAIR
POINT
PRESSURE TREATED
PAINTED
RADIUS
REFLECTED CEILING PLAN
ROOF DRAIN
REFERENCE
REINFORCED
REQUIRED
RESILIENT
ROOM
ROUGH OPENING
RAIN WATER LEADER
SOUTH
SOLID CORE
SCHEDULE
SECTION
SHELF
SHOWER
SHEET
SHEET METAL
SIMILAR
SPECIFICATION
SQUARE
STAINED GRADE
STAINLESS STEEL
STANDARD
STEEL
STORAGE
STRUCTURAL
SUSPENDED
APPLICABLE CODES
INTERNATIONAL BUILDING CODE, 2013
STATE OF CALIFORNIA TITLE 20, APPLIANCE APPLIANCE EFFICIENCY REGULATIONS
STATE OF CALIFORNIA TITLE 24: LATEST EDITION
PART l CALIFORNIA ADMINISTRATIVE CODE PART 2 CALIFORNIA BUILDING CODE VOLUMES l & 2
PART 3 CALIFORNIA ELECTRICAL CODE AND THE NATIONAL ELECTRICAL CODE
PART 4 CALIFORNIA MECHANICAL CODE AND THE UNIFORM MECHANICAL
CODE
PART 5 CALIFORNIA PLUMBING CODE AND UNIFORM PLUMBING CODE
PART 6 CALIFORNIA ENERGY CODE
PART 7 CALIFORNIA ELEVATOR SAFETY CONSTRUCTION CODE
PART 8 CALIF. FIRE CODE AND UNIFORM FIRE CODE
NFPA 101 LIFE SAFETY CODE
,'cDAi•1c (; 0 0'1%ERICi\tlS \1/ITI I DIS;*18ILlflES ;•:GGE551Blb:lifl' GkllliELlt4E6 FOR -9elloDl~465 .~~ID
~ACltlTI~. t1FA~ (t11~1FC~M FEEIE~AL ACCESSIBILIT'l S'fi'<t~DiA<RD&}
,4'.tMi~iU~ '¥lfi f P~" f1'{ 1Wf{A 1911) c'7 11 @II t "8e fhl>IL> iiA ~ M64'.t)
.A:::::~1:7::!~· ~f /tcffih11>1u11 ~ (MA-Ir?)
FOREST:
STANISLAUS NATIONAL FOREST
PROJECT
NAME:
GROVELAND HOTSHOTS OFFICE AND GARAGE
DRAWING
NAME:
TITLE SHEET
HWY 120 -----,
SITE LOCATION
LOCATION MAP
TO YOSEMITE
56 E20l 57 E30l 58 E40l
I l
NOTTO SCALE
THE GROVELAND HOTSHOTS OFFICE AND GARAGE IS TO BE LOCATED AT THE GROVELAND
RANGER STATION, 24545 HIGHWAY 120, GROVELAND CA 95321, ON THE SOUTH SIDE OF
CALIFORNIA STATE HIGHWAY 120, NEAR THE COMMUNITY OF BUCK MEADOWS, CA.
GROVELAND RANGER DISTRICT, STANISLAUS NATIONAL FOREST. APN: 066 250 30
~ fuis PACIFIC •
SOUTHWEST
RS REGION ~IJloJll\~ u s·o A FORESTSERVICE
DRAWING INDEX
TITLE SHEET
CIVIL NOTES, LEGEND, ABBREVIATIONS
EXISTING SITE PLAN
DEMOLITION PLAN
PROPOSED SITE PLAN
GRADING & DRAINAGE PLAN
UTILITY PLAN
EROSION CONTROL PLAN
CIVIL CONSTRUCTION DETAILS
CIVIL CONSTRUCTION DETAILS
CIVIL CONSTRUCTION DETAILS
CIVIL CONSTRUCTION DETAILS
SCOPE OF WORK PLAN
CODE ANALISIS
HORIZONTAL CONTROL PLAN
SITE PLAN
FLOOR PLAN
REFLECTED CEILING PLAN
ROOF PLAN
EXTERIOR ELEVATIONS
EXTERIOR ELEVATIONS
BUILDING SECTIONS
BUILDING SECTIONS
WALL SECTIONS
EXTERIOR DETAILS
EXTERIOR DETAILS
INTERIOR ELEVATIONS
INTERIOR ELEVATIONS
INTERIOR ELEVATIONS
DOOR TYPES, SIGNAGE, AND DOOR SCHEDULE
DOOR DETAILS
WINDOW TYPES AND SCHEDULE
INTERIOR CASEWORK DETAILS
INTERIOR WALL TYPES
FINISH FLOOR PLAN & SCHEDULE
GENERAL NOTES, SCHEDULES
STRUCTURAL DETAILS -GENERAL
FOUNDATION AND SHEER WALL PLAN
ROOF FRAMING PLAN
STRUCTURAL DETAILS
STRUCTURAL DETAILS
PLUMBING NOTES, LEGEND, SCHEDULES AND ABBREVS.
PLUMBING FLOOR PLAN - WASTE & VENT
PLUMBING FLOOR PLAN - WATER & GAS
PLUMBING DETAILS
MECHANICAL NOTES, LEGEND & ABBREVIATIONS
MECHANICAL SCHEDULES
MECHANICAL DETAILS
MECHANICAL DETAILS
MECHANICAL FLOOR PLAN
ENERGY COMPLIANCE DOCUMENTATION
ENERGY COMPLIANCE DOCUMENTATION
SYMBOL LIST, GENERAL NOTES & SHEET INDEX
LUMINAIRE SCHEDULE
OVERALL SITE PLAN
FLOOR PLAN - LIGHTING
FLOOR PLAN - POWER & SIGNAL
SINGLE LINE DIAGRAM AND PANEL SCHEDULE
NATIONAL FOREST
DATE: /'(pv. 30, ~I§
MIKE BRADSHAW
FOREST ENGINEER
DA~O/ 2.0 I:;
JIM JUNETI I
DISTR RAN R
0 1
REGIO
DATE: 0£{!; 1c2-1 ?:-? rr-"
EUGENE KIM
REGIONAL ARCHITECT
DATE: Yc;c. 14 1 Ro lb
TYRONE KELLY
REGIONAL ENGINEER
DRAWING
TOOO
SHEET l OF 58
Pacific Southwest Region R5 USDA Forest Service
Stanislaus National Forest Groveland Fire Station Section 27 T1S, R17E M.D.B.M
ISSUE DATE:
DRAWN BY:
CHECKED BY:
SCALE:
DRAWING:
PROJECT NO:
ZPG
15-06.09
DRAWING
11/12/15
KTQ
Gr ov ela nd
H ot sh ot s:
Of fic e an d
Ga ra ge Gr ov ela nd R an ge r S ta tio n
Hi gh wa y 1
Gr ov ela nd
, C ali fo rn ia
1. UTILITIES AND UNDERGROUND FACILITIES INDICATED ARE BASED ON SURFACE OBSERVATIONS AND FOR INFORMATION ONLY. IT IS THE
CONTRACTOR'S RESPONSIBILITY TO VERIFY THE LOCATION AND DEPTH. NEITHER THE OWNER NOR THE DESIGN PROFESSIONAL ASSUMES
RESPONSIBILITIES THAT THE UTILITIES AND UNDERGROUND FACILITIES INDICATED WILL BE AS DEPICTED.
2. CONTRACTOR TO CONTACT UNDERGROUND SERVICE ALERT U.S.A. 800.227.2600 FORTY-EIGHT HOURS (48) PRIOR TO THE BEGINNING OF WORK
TO HAVE THE LOCATION OF EXISTING UNDERGROUND UTILITIES MARKED. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO IDENTIFY, LOCATE, AND PROTECT ALL UNDERGROUND FACILITIES.
3. THE CONTRACTOR SHALL HIRE A STREET CLEANING CONTRACTOR TO CLEAN UP DIRT AND DEBRIS ATTRIBUTABLE TO THE CONSTRUCTION
ACTIVITIES AT THE END OF THE PROJECT.
4. ALL GRADING SHALL BE PERFORMED IN SUCH A MANNER TO COMPLY WITH THE STANDARDS ESTABLISHED BY THE AIR QUALITY MAINTENANCE
DISTRICT FOR AIRBORNE PARTICULATES. (DUST)
5. ALL GRADING SHALL CONFORM TO APPROVED SPECIFICATIONS PRESENTED HEREON, ATTACHED HERETO, AND/OR INCLUDED AS PART OF THE
PROJECT. ALL GRADING WORK SHALL BE OBSERVED AND APPROVED BY THE SOILS ENGINEER. THE SOILS ENGINEER SHALL BE NOTIFIED AT
LEAST 48 HOURS BEFORE BEGINNING ANY GRADING. UNOBSERVED AND UNAPPROVED GRADING WORK SHALL BE REMOVED AND REDONE AT THE
CONTRACTORS EXPENSE.
6. ALL MATERIALS REQUIRED FOR THE COMPLETE EXECUTION OF THE PROJECT SHALL BE FURNISHED AND INSTALLED BY THE CONTRACTOR
UNLESS OTHERWISE NOTED.
7. THE CONTRACTOR SHALL PROVIDE ALL LIGHTS, SIGNS, BARRICADES, FLAGMEN OR OTHER DEVICES NECESSARY TO PROVIDE FOR PUBLIC
SAFETY DURING THE CONSTRUCTION PERIOD.
8. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE REPLACEMENT OF ANY EXISTING UNDERGROUND FACILITIES DAMAGED DURING THE
CONSTRUCTION PERIOD.
9. THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL ENCROACHMENT, EXCAVATION, CONCRETE, ELECTRICAL, PLUMBING, ETC.
PERMITS NECESSARY PRIOR TO BEGINNING CONSTRUCTION FOR ANY WORK.
10.THE CONTRACTOR SHALL HAVE A SUPERINTENDENT OR REPRESENTATIVE ON SITE AT ALL TIMES DURING CONSTRUCTION.
11. A CONTAINED AND COVERED AREA ON-SITE SHALL BE USED FOR STORAGE OF CEMENT BAGS, PAINTS, FLAMMABLE, OILS, FERTILIZERS, PESTICIDES, OR ANY OTHER MATERIALS THAT HAVE POTENTIAL FOR BEING DISCHARGED WITHIN AND/OR FROM THE SITE.
12. ALL CONSTRICTION DEBRIS SHALL BE GATHERED ON A REGULAR BASIS AND PLACED IN A DUMPSTER WHICH IS EMPTIED OR REMOVED WEEKLY.
WHEN FEASIBLE, TARPS SHALL BE USED ON THE GROUND TO COLLECT FALLEN DEBRIS OR SPLATTERS THAT COULD CONTRIBUTE TO
STORMWATER POLLUTION.
13. ANY TEMPORARY ON-SITE CONSTRUCTION PILES SHALL BE SECURELY COVERED WITH A TARP OR OTHER DEVICE TO CONTAIN DEBRIS.
14.CONCRETE TRUCKS AND CONCRETE FINISHING OPERATIONS MUST UTILIZE AN ONSITE WASH-OUT BASIN PROVIDED BY THE CONTRACTOR
ONSITE.
CONSTRUCTION NOTES
1. TRENCH EXCAVATIONS FOR UTILITIES SHOULD BE BEDDED AND BACKFILLED IN ACCORDANCE WITH THE REQUIREMENTS OF THE SERVICE
PROVIDER (UTILITY COMPANY), LOCAL JURISDICTION, AND THE GEOTECHNICAL REPORT.
2. BEDDING SHOULD BE PLACED 4 INCHES BELOW CONDUIT OR PIPE TO AT LEAST 1 FOOT ABOVE CONDUIT OR PIPE.
3. BEDDING SHOULD HAVE A SAND EQUIVALENT VALUE OF AT LEAST 30 SO THAT THE BEDDING MATERIAL FLOWS INTO THE PIPE HAUNCHES MORE
EASILY DURING BACKFILLING OPERATION. THIS WILL REDUCE VOIDS AT THE PIPE HAUNCHES AND IMPROVE PIPE SIDEWALL SUPPORT BY THE
BACKFILL.
4. SAND BEDDING SHOULD NOT BE JETTED INTO PLACE, BUT SHOULD BE MECHANICALLY COMPACTED TO A MINIMUM OF 90 PERCENT RELATIVE
COMPACTION (ASTM D-1557.)
5. WITHIN PARKING AREAS, THE UPPER 12 INCHES OF BACKFILL IN ALL TRENCHES (INCLUDING CULVERTS) SHOULD BE COMPACTED TO 95 PERCENT
RELATIVE COMPACTION (ASTM D-1557.)
UTILITY TRENCHING
1. ENGINEERED FILL USED TO SUPPORT FOUNDATIONS, SLABS-ON-GRADE, OR DRIVEWAY AND PARKING AREAS SHOULD MEET THE REQUIREMENTS
SPECIFIED WITHIN THESE PLANS, COMPLY WITH APPENDIX J OF THE 2013 CALIFORNIA BUILDING CODE, LOCAL ORDINANCES, FOLLOW
CONSTRUCTION STANDARDS OF PRACTICE AND COMPLY WITH THE GEOTECHNICAL REPORT PROVIDED BY CONDOR EARTH TECHNOLOGIES, INC.
2. ONSITE MATERIALS MAY BE ABLE TO BE USED IF THEY MEET THE GRADATION REQUIREMENTS AND SOIL CHARACTERISTICS AS DEFINED IN THE
GEOTECHNICAL REPORT. ONSITE MATERIALS MUST BE STRIPPED AND PROCESSED. PROCESSING MAY INCLUDED CRUSHING THE BOULDER SIZED
MATERIALS AND/OR USE OF A "GRIZZLY" TO PRODUCE THE GRADATION REQUIREMENTS.
3. BOULDER-SIZED MATERIAL CAN BE USED AS RIP-RAP AND PLACED ON THE FACE OF FILL SLOPES.
4. INORGANIC IMPORT MATERIAL, HAVING LOW POTENTIAL FOR EXPANSION AND MEETING THE CRITERIA GIVEN MAY ALSO BE USED AS
ENGINEERED FILL. A SAMPLE OF ANY PROPOSED IMPORT MATERIAL SHOULD BE PROVIDED TO A GEOTECHINICAL ENGINEER AND TESTED TO
CONFIRM ITS SUITABILITY PRIOR TO TRANSPORTING THE MATERIAL ON-SITE.
5. ENGINEERED FILL COMPOSED OF SUITABLE MATERIALS SHOULD BE PLACED IN HORIZONTAL LAYERS NOT EXCEEDING 8 INCHES IN LOOSE
THICKNESS, WATER CONDITIONED TO AT LEAST THE OPTIMUM VALUE, AND COMPACTED TO THE MINIMUM VALUES BASED ON ASTM D-1557.
6. MINIMUM COMPACTED VALUES PER ASTM D-1557
90 PERCENT RELATIVE COMPACTION BENEATH NEW STRUCTURES AND SLABS-ON-GRADE, WITHIN AN AREA EXTENDING 4 FEET
OUTSIDE THE STRUCTURE AND SLAB AREA, AND ALL OTHER FILL LOCATIONS.
95 PERCENT RELATIVE COMPACTION FOR THE UPPER 6 INCHES OF ALL DRIVEWAY AND PARKING AREA SUBGRADES.
7. WHERE FILL IS PLACED ON AN EXISTING SLOPE STEEPER THAN 5H:1V, A KEYWAY SHOULD BE CONSTRUCTED BELOW THE TOE OF THE FILL AND
FILL SHOULD BE BENCHED INTO COMPETENT SOIL/ROCK.
8. KEYWAYS
KEYWAY BOTTOM SHOULD BE AT LEAST ONE-HALF OF THE FILL SLOPE HEIGHT OR 10 FEET, WHICHEVER IS SMALLER.
FILL SHOULD BE EMBEDDED INTO FIRM NATURAL SOIL OR BEDROCK AS IT IS BROUGHT UP IN LAYERS TO REMOVE ALL LOOSE
OR SOFT MATERIAL BENEATH THE FILL.
A SUBDRAIN SHOULD BE INSTALLED AT THE BACK OF THE KEYWAY AND/OR WHERE SEEPAGE IS OBSERVED, IF REQUIRED.
9. IF SEEPAGE OR SATURATED SOILS ARE ENCOUNTERED DURING GRADING, RECOMMENDATIONS FOR SUBDRAINAGE OR SPECIAL GRADING
SHOULD BE OBTAINED FROM A GEOTECHNICAL ENGINEER.
10. TO REDUCE THE POSSIBILITY OF SURFICIAL FAILURES (SLOPE FAILURES WHICH OCCUR IN MATERIAL WITHIN 2 TO 3 FEET OF THE FINISHED FACE
OF SLOPE,) THE FILL MATERIAL SHOULD BE UNIFORMLY COMPACT TO THE FINISH FACE OF THE FILL SLOPE.
11. PREFERABLE FILL SLOPE CONSTRUCTION INCLUDES AN OVER-BUILT FILL CUT BACK TO A COMPACTED FINISH SLOPE.
12. PROPER TEMPORARY AND PERMANENT EROSION PROTECTION SHOULD BE PROVIDED ON ALL FILL AND CUT SLOPES.
13. ALL FINISHED SURFACES SHOULD BE GRADED TO DRAIN AWAY FROM FOUNDATIONS.
14. SUBGRADE SURFACES SHOULD BE FINISHED TRUE TO LINE AND GRADE AND PRESENT A SMOOTH, FIRM, UNYEILDING SURFACE, AND SHOULD
BE MAINTAINED MOIST AND FREE OF SHRINKAGE CRACKS UNTIL COVERED BY PERMANENT CONSTRUCTION.
GENERAL GRADING NOTES
1. THE INFORMATION ON THIS PLAN IS INTENDED TO BE USED AS A GUIDELINE FOR THE CONTRACTOR AND SUBCONTRACTORS TO INSTALL
WATER POLLUTION CONTROL DEVICES AT GENERAL LOCATIONS THROUGHOUT THE SITE. FIELD CONDITIONS MAY NECESSITATE
MODIFICATIONS.
2. EROSION CONTROL MEASURES FOR WIND, WATER, MATERIAL STOCKPILES, AND TRACKING SHALL BE IMPLEMENTED ON ALL PROJECTS
AT ALL TIMES AND SHALL INCLUDE SOURCE CONTROL, INCLUDING PROTECTION OF STOCKPILES, PROTECTION OF SLOPES, PROTECTION
OF ALL DISTURBED AREAS, PROTECTION OF ACCESSES, AND PERIMETER CONTAINMENT MEASURES.
3. CONTRACTOR SHALL CONSTRUCT AND MAINTAIN ALL MEASURES TO PREVENT SOIL FROM ERODING ONTO ADJACENT PROPERTY, STREETS,DRAINAGE SYSTEMS, AND WATERWAYS. ALL DEVICES SHALL BE CLEANED OF MUD, DEBRIS, AND OTHER ERODED MATERIALS
DURING THE SITE CLEARING AND DEVELOPMENT.
4. SITE INSPECTIONS AND APPROPRIATE MAINTENANCE OF ALL EROSION CONTROL MEASURES/DEVICES SHALL BE CONDUCTED AND
DOCUMENTED AT ALL TIMES DURING CONSTRUCTION AND ESPECIALLY PRIOR TO, DURING, AND AFTER RAIN EVENTS.
5. EROSION AND SEDIMENT CONTROL MEASURES SHALL BE KEPT IN PLACE FOR THE DURATION OF THE CLEARING AND CONSTRUCTION
OPERATIONS.
6. A SUB-BASE COURSE WILL BE APPLIED IMMEDIATELY FOLLOWING ROUGH GRADING AND INSTALLATION OF IMPROVEMENTS IN ORDER
TO STABILIZE STREETS, ROADS, DRIVEWAYS, AND PARKING AREAS. IN AREAS WHERE NO UTILITIES ARE PRESENT, SUB-BASE SHALL BE
INSTALLED WITHIN 15 DAYS OR AT PRELIMINARY GRADING, WHERE FEASIBLE.
7. IMMEDIATELY FOLLOWING INITIAL DISTURBANCE OR ROUGH GRADING ALL CRITICAL AREAS SUBJECT TO EROSION (I.E. STEEP SLOPES, ROADWAY EMBANKMENTS) WILL RECEIVE TEMPORARY SEEDING IN COMBINATION WITH STRAW MULCH OR SUITABLE EQUIVALENT.
8. TEMPORARY AND PERMANENT SEEDING OPERATIONS SHALL BE INITIATED WITHIN 7 DAYS AFTER REACHING FINAL GRADE, OR UPON
SUSPENSION OF GRADING OPERATIONS FOR ANTICIPATED DURATION OF GREATER THAN 30 DAYS, OR UPON COMPLETION OF GRADING
OPERATIONS FOR A SPECIFIC AREA.
9. ANY STEEP SLOPES RECEIVING PIPELINE INSTALLATION WILL BE BACKFILLED AND STABILIZED DAILY, AS THE INSTALLATION PROCEEDS.
(I.E. SLOPES GREATER THAN 3:1)
10. THE CONTRACTOR SHALL INSTALL ADDITIONAL EROSION CONTROL MEASURES AS MAY BE REQUIRED BY UNFORSEEN CIRCUMSTANCES
THAT MAY ARISE.
11. THE CONTRACTOR SHALL BE RESPONSIBLE FOR AND SHALL TAKE NECESSARY PRECAUTIONS TO PREVENT PUBLIC TRESPASS ONTO
AREAS WHERE IMPOUNDED WATERS CREATE A HAZARDOUS CONDITION.
12. THE CONTRACTOR SHALL MONITOR AND TAKE PRECAUTIONS TO CONTROL DUST AND OTHER AIR POLLUTANTS, INCLUDING BUT NOT
LIMITED TO USING WATER OR CHEMICALS, LIMITING NUMBER OF VEHICLES ALLOWED ONSITE, MINIMIZING OPERATING SPEED OF ALL
VEHICLES ETC. ALSO, THE CONTRACTOR WILL BE RESPONSIBLE FOR THE DAILY SWEEPING OF PUBLIC RIGHT-OF-WAY SHOULD SEDIMENT
ACCUMULATE ON PAVED SURFACES.
13. APPROVAL OF AN EROSION AND SEDIMENT CONTROL PLANS AND ACQUISITION OF A LAND DISTURBING PERMIT DOES NOT RELIEVE
THE OWNER/ DEVELOPER FROM OBTAINING APPLICABLE FEDERAL, STATE, AND OTHER LOCAL PERMITS, OR FROM COMPLYING WITH
PERTINENT FEDERAL, STATE, AND LOCAL LAWS AND REGULATIONS.
PROPOSED PROJECT AREA = ±0.5 ACRES
EROSION CONTROL GENERAL NOTES
IF THERE ARE ANY DISCREPANCIES BETWEEN THE DIMENSIONS IN THE DRAWINGS AND EXISTING CONDITIONS WHICH WILL AFFECT THE WORK, THE CONTRACTOR SHALL BRING SUCH DISCREPANCIES TO THE ATTENTION OF THE ENGINEER FOR ADJUSTMENT BEFORE PROCEEDING WITH THE
WORK. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROPER FITTING OF ALL WORK AND FOR THE COORDINATION OF ALL TRADES, SUBCONTRACTORS, AND PERSONS ENGAGED UPON THIS CONTRACT.
DISCREPANCIES
THE TYPES, LOCATIONS, SIZES AND / OR DEPTHS OF EXISTING UNDERGROUND UTILITIES AS SHOWN ARE APPROXIMATE AND WERE OBTAINED
FROM SOURCES OF VARYING RELIABILITY. ONLY ACTUAL EXCAVATION WILL REVEAL THE TYPES, EXTENT, SIZES, LOCATIONS, AND DEPTHS OF
SUCH UNDERGROUND UTILITIES. A REASONABLE EFFORT HAS BEEN MADE TO LOCATE AND DELINEATE ALL KNOWN UNDERGROUND UTILITIES.
HOWEVER, THE ENGINEER CAN ASSUME NO RESPONSIBILITY FOR THE COMPLETENESS OR ACCURACY OF THE DELINEATION OF SUCH
UNDERGROUND UTILITIES WHICH MAY BE ENCOUNTERED, BUT ARE NOT SHOWN ON THESE PLANS. THE CONTRACTOR SHALL BE RESPONSIBLE
FOR LOCATING ALL UNDERGROUND FACILITIES AND UTILITIES BY POTHOLING PRIOR TO COMMENCING CONSTRUCTION.
UTILITY / POTHOLE
1. ALL SITE WORK SHALL BE IN CONFORMANCE WITH TITLE 24 OF THE CALIFORNIA ADMINISTRATIVE CODE AND WITH THE AMERICANS WITH
DISABILITIES ACT.
2. CURB RAMPS SHALL NOT EXCEED A SLOPE OF 1:12 (8.33%.)
3. PATH OF TRAVEL TO BUILDINGS SHALL NOT EXCEED A SLOPE OF 1:20 (5%) UNLESS RAILINGS ARE SHOWN ON ARCHITECTURAL PLANS, IN WHICH
CASE THE SLOPE SHALL NOT EXCEED 1:12 (8.33%).
4. A 2% MAXIMUM SLOPE LANDING SHALL BE PROVIDED AT PRIMARY ENTRANCES TO BUILDINGS, THE LANDINGS SHALL HAVE A MINIMUM WIDTH OF
60" AND A MINIMUM DEPTH OF 60" WHEN THE DOOR OPENS INTO THE BUILDING, AND 42" PLUS THE WIDTH OF THE DOOR WHEN THE DOOR OPENS
ONTO THE LANDING.
5. RAMPS ARE DEFINED AS ANY WALKWAY BETWEEN SLOPES OF 1:20 (5%) AND 1:12 (8.33%), AND SHALL HAVE A MINIMUM WIDTH OF 48" AND A
MAXIMUM CROSS-SLOPE OF 2%. RAMPS EXCEEDING 2'-6" VERTICAL CHANGE SHALL HAVE INTERMEDIATE (2% MAXIMUM SLOPE) LANDINGS HAVING
A MINIMUM LENGTH IN THE DIRECTION OF TRAVEL OF 60". BOTTOM LANDINGS AT CHANGES IN RAMP DIRECTION SHALL HAVE A MINIMUM LENGTH
OF 72".
6. MAXIMUM CROSS SLOPE ON ANY SIDEWALK OR RAMP SHALL BE 2% MAXIMUM. MAXIMUM SLOPE WITHIN PARKING STALLS DESIGNATED AS
ACCESSIBLE PARKING SHALL BE 2% IN ANY DIRECTION.
7. ALL SIDEWALK SHALL HAVE A 4' MINIMUM CLEAR WIDTH FOR ACCESSIBLE CONFORMANCE.
ADA NOTES
PER NATIONAL GEODETIC SURVEY (NGS):
DESIGNATION E 79
PID HS0989
STATE/COUNTY CA/TUOLUMNE
USGS QUAD JAWBONE RIDGE (1979)
NAD 83(1986) POSITION 37 49' 19.0" (N) 120 05' 58.1" (W)
NAVD 88 ORTHO HEIGHT 3123.03 FEET
MARKER BENCH MARK DISK
NOTE: HORIZ COORDINATES ESTABLISHED BY AUTONOMOUS HAND HELD
GPS OBSERVATIONS AND HAVE AN ESTIMATED ACCURACY OF ±10 METERS
RECOVERY NOTE BY GEOCACHING 2008 (PFW)
MARKER IS APPROXIMATELY 135 WEST OF THE SOUTHWEST CORNER OF
THE RANGER STATION
BENCHMARKS
IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO INCLUDE ALL MATERIAL AND LABOR REQUIRED WITHIN THE BID PRICE, FOR EARTHWORK
CONSTRUCTION, TO CARRY OUT THE CUT/FILL AND/OR IMPORT/EXPORT AS NECESSARY TO MEET THE DESIGN GRADES SHOWN ON THE PLANS.
THE CONTRACTOR IS TO DELIVER TO THE OWNER THE PROJECT IN A COMPLETE AND OPERATIONAL MANNER. EARTHWORK QUANTITIES SHOWN
ON THE PLANS OR REPRESENTED BY THE ENGINEER ARE APPROXIMATE AND ARE FOR GRADING PLAN PURPOSES ONLY. THE CONTRACTOR IS
RESPONSIBLE FOR INVESTIGATION OR STUDIES THAT ARE REQUIRED BY THE CONTRACTOR TO SATISFY THIS REQUIREMENT. NO ADDITIONAL
COMPENSATION SHALL BE PAID FOR SAID CUT/FILL AND/OR IMPORT/EXPORT.
EARTHWORK NOTE
ASBESTOS CONTAINING SIDING IS KNOWN TO EXIST WITHIN THE PROJECT AREA. THE CONTRACTOR WILL PROTECT ALL ASBESTOS CONTAINING
ITEMS DURING THE EXECUTION OF THIS CONTRACT. ADDITIONALLY THE CONTRACTOR WILL COMPLY WITH ALL LOCAL, STATE, AND FEDERAL
REGULATIONS REGARDING CONSTRUCTION ACTIVITIES NEAR ASBESTOS CONTAINING MATERIALS.
HAZARDOUS MATERIALS NOTE
C0.1 CIVIL NOTES, LEGEND, AND ABBREVIATION
C1.0 EXISTING SITE PLAN
C2.0 DEMOLITION PLAN
C3.0 PROPOSED SITE PLAN
C4.0 GRADING & DRAINAGE PLAN
C5.0 UTILITY PLAN
C6.0 EROSION CONTROL PLAN
C7.0 CIVIL CONSTRUCTION DETAILS
C7.1 CIVIL CONSTRUCTION DETAILS
C7.2 CIVIL CONSTRUCTION DETAILS
C7.3 CIVIL CONSTRUCTION DETAILS
CIVIL SHEET INDEX
Point Number Easting Northing Point Elevation Description
1 19754.4556' 9600.7818' 3139.28' SETPK
2 19887.6394' 9677.2720' 3140.21' SET PK
3 19917.0241' 9837.6862' 3159.02' SETSS
4 20115.7766' 9768.5553' 3146.43' SET PK
5 20098.1541' 9644.5098' 3137.03' SET PK
6 19887.6490' 9677.2834' 3140.21' FD PK
101 19889.9609' 9663.1343' 3141.30' SETTBM
102 19914.7541' 9796.1941' 3149.00' SET TBM
TEMPORARY SITE BENCHMARK/ CONTROL
WATER VALVE
WATER METER
LAMP POST
ELECTRICAL VAULT
UTILITY POLE
GUY WIRE
TELEPHONE PEDESTAL
SEWER
INSPECTION RISER
PROPANE TANK
GAS VALVE
DRAIN INLET
FLOW
FIRE HYDRANT
CEDAR TREE
PINE TREE
OAK TREE
TREE (UNSPECIFIED)
SIGN
SPOT ELEVATION
SLOPE
ELECTRICAL LINE
GAS LINE
WATER LINE
SEWER LINE
LIMIT VEGETATION OR DRIPLINE
(E) ROCK BREAK
(E) ASPHALT SURFACE
(E) CONCRETE SURFACE
(E) GRAVEL SURFACE
(E) BUILDING
OR
ASPHALT CONCRETE SURFACE 12,500 SQ
CONCRETE SURFACE 2,000 SQ
CONCRETE DRAINAGE SWALE 220 LF
GRAVEL DRAINAGE SWALE 50 LF
GRAVEL EDGE PROTECTION 1,600 SQ
TOTAL DISTURBED AREA 23,000 SQ
NOTE: QUANTITIES BASED ON PLANIMETRIC MEASUREMENTS, SLOPE CORRECTIONS HAVE
NOT BEEN APPLIED. CONTRACTOR MUST FIELD VERIFY QUANTITIES NOTED.
AB - AGGREGATE BASE
AC - ASPHALT CONCRETE
AD - AREA DRAIN
ADA - AMERICANS WITH DISABILITIES ACT
BFP - BACK FLOW PREVENTER
BLDG - BUILDING
BM - BENCH MARK
BOL - BOLLARD
C&G - CURB AND GUTTER
CB - CATCH BASIN
CIP - CAST IRON PIPE
CL - CENTERLINE
CMP - CORRUGATED METAL PIPE
CO - CLEAN OUT
CONC - CONCRETE
CY - CUBIC YARD
DI - DROP INLET
DIP - DUCTILE IRON PIPE
DW - DOMESTIC WATER
EPV - EDGE OF PAVEMENT
ELEV - ELEVATION
E, EXIST - EXISTING
FC - FACE OF CURB
FF - FINISHED FLOOR
FG - FINISHED GRADE
FH - FIRE HYDRANT
FL - FLOW LINE
FND - FOUNDATION
FS - FINISHED SURFACE
FT - FOOT
GB - GRADE BREAK
GV - GATE VALVE
HCR - ACCESSIBLE RAMP
HP - HIGH POINT
INV - INVERT ELEVATION
LF - LINEAR FEET
LP - LOW POINT
MAX - MAXIMUM
MEP - MECHANICAL/ELECTRICAL/PLUMBING
MH - MANHOLE
MIN - MINIMUM
MON - MONUMENT
NTS - NOT TO SCALE
PL - PROPERTY LINE
POC - POINT OF CURVE
PP - POWER POLE
PVC - POLYVINYL CHLORIDE PIPE
R - RADIUS
RCP - REINFORCED CONCRETE PIPE
R/W - RIGHT OF WAY
SD - STORM DRAIN
SF - SQUARE FEET
SS - SANITARY SEWER
STA - STATION
STD - STANDARD
S/W - SIDEWALK
TBM - TEMPORARY BENCH MARK
TC - TOP OF CURB
TD - TRENCH DRAIN
TOE - TOE OF SLOPE
TOS - TOP OF STAIR
TOW - TOP OF WALL
TS - TOP OF SLAB
TYP - TYPICAL
UON - UNLESS OTHERWISE NOTED
U/G - UNDERGROUND
WM - WATER METER
WV - WATER VALVE
QUANTITIES
1. ALL CONCRETE REINFORCEMENT MUST BE SECURED AND SUPPORTED PRIOR TO CONCRETE PLACEMENT.
2. MINIMUM SUPPORT WITH 2" x 2" x 2" CONCRETE "DOBIES" WITH WIRE, OR EQUAL (SUBJECT TO APPROVAL
BY THE CONTRACTING OFFICER.) MINIMUM PLACEMENT AT EVERY OTHER REINFORCING STEEL CROSSING.
* DOBIES - REFERENCE CONTAINED IN DETAILS THAT REFER TO THE ABOVE NOTES
CONCRETE REINFORCEMENT SUPPORT
REFER TO SPECIAL INSPECTION REQUIREMENTS, SHEET C7.2
SPECIAL INSPECTIONS
E. SITE
C0.1
Co ve r s he et fo r:
NTS
Pacific Southwest Region R5 USDA Forest Service
Stanislaus National Forest Groveland Fire Station Section 27 T1S, R17E M.D.B.M
ISSUE DATE:
DRAWN BY:
CHECKED BY:
SCALE:
DRAWING:
PROJECT NO:
ZPG
15-06.09
Gr ov ela nd
H ot sh ot s:
Of fic e an d
Ga ra ge Gr ov ela nd R an ge r S ta tio n
Hi gh wa y 1
Gr ov ela nd
, C ali fo rn ia
DRAWING
11/12/15
KTQ
- GARAGE
- COVERED PATIO
- WOOD TERRACING
- ELEVATED CONCRETE SURFACE
- STORAGE STRUCTURE
- BUILDING
- FUELING STATION TO REMAIN
- POWER SERVICE PANEL
- SEWER LINE
- OVERHEAD POWER LINE
- WATER LINE
- FLAG POLE
- FITNESS EQUIPMENT
- COMMUNICATION VAULT
- VEHICLE SERVICE PIT (BENEATH SURFACE)
- CORRUGATED METAL PIPE CULVERT W/ UTILITIES INSIDE
- COMMUNICATION SERVICE PANEL
- SHED
- GAS LINE - BUILDING SERVICE
- SERVICE PEDESTAL
- APPROXIMATELY 2300 SQ.FT. BUILDING TO BE REMOVED
* LOCATION PROVIDED BY U.S.F.S., CONTRACTOR TO
FIELD VERIFY LOCATION
(ALL INFORMATION OUTSIDE THE PROJECT LIMITS PROVIDED
BY U.S.F.S. MUST BE FIELD VERIFIED BY THE CONTRACTOR)
REFERENCE NOTES
9*
10*
11*
TEMPORARY SITE BENCHMARK/ CONTROL
SPOT ELEVATION
WATER VALVE
WATER METER
LAMP POST
ELECTRICAL VAULT
UTILITY POLE
GUY WIRE
TELEPHONE PEDESTAL
SEWER
INSPECTION RISER
PROPANE TANK
GAS VALVE
DRAIN INLET
FLOW LINE
FIRE HYDRANT
CEDAR TREE
PINE TREE
OAK TREE
TREE (UNSPECIFIED)
SIGN
ELECTRICAL LINE
GAS LINE
WATER LINE
SEWER LINE
LIMIT VEGETATION OR DRIPLINE
(E) ROCK BREAK
(E) ASPHALT SURFACE
(E) CONCRETE SURFACE
(E) GRAVEL SURFACE
(E) BUILDING
OR
LEGEND
E. SITE
C1.0
Ex ist ing S ite P lan fo r:
1"=20'
BENCHMARKS
Point Number Easting Northing Point Elevation Description
1 19754.4556' 9600.7818' 3139.28' SETPK
2 19887.6394' 9677.2720' 3140.21' SET PK
3 19917.0241' 9837.6862' 3159.02' SETSS
4 20115.7766' 9768.5553' 3146.43' SET PK
5 20098.1541' 9644.5098' 3137.03' SET PK
6 19887.6490' 9677.2834' 3140.21' FD PK
101 19889.9609' 9663.1343' 3141.30' SETTBM
102 19914.7541' 9796.1941' 3149.00' SET TBM
PER NATIONAL GEODETIC SURVEY (NGS):
DESIGNATION E 79
PID HS0989
STATE/COUNTY CA/TUOLUMNE
USGS QUAD JAWBONE RIDGE (1979)
NAD 83(1986) POSITION 37 49' 19.0" (N) 120 05' 58.1" (W)
NAVD 88 ORTHO HEIGHT 3123.03 FEET
MARKER BENCH MARK DISK
thughes02 Typewritten Text
BUILDING 2205
thughes02 Typewritten Text
BUILDING 2505
thughes02 Line thughes02 Typewritten Text
BUILDING
thughes02 Line thughes02 Typewritten Text
NO
PARKING
Pacific Southwest Region R5 USDA Forest Service
Stanislaus National Forest Groveland Fire Station Section 27 T1S, R17E M.D.B.M
ISSUE DATE:
DRAWN BY:
CHECKED BY:
SCALE:
DRAWING:
PROJECT NO:
ZPG
15-06.09
DRAWING
11/12/15
KTQ
Gr ov ela nd
H ot sh ot s:
Of fic e an d
Ga ra ge Gr ov ela nd R an ge r S ta tio n
Hi gh wa y 1
Gr ov ela nd
, C ali fo rn ia
LEGEND
SPOT ELEVATION, PROPOSED
SLOPE, PROPOSED
GRADING & DRAINAGE PLAN
GRAD & DRNG
C4.0
Gr ad ing
D ra ina ge
P lan fo r:
1"=10'
CONTOUR INTERVAL = 2'
thughes02 Line thughes02 Typewritten Text 3146.00 thughes02 Typewritten Text 3146.00 thughes02 Line thughes02 Polygon thughes02 Polygon thughes02 Line thughes02 Typewritten Text 3146.00 thughes02 Polygon thughes02 Line thughes02 Typewritten Text <- 0.5% thughes02 Line thughes02 Polygon thughes02 Line thughes02 Typewritten Text 3146.00 thughes02 Polygon thughes02 Typewritten Text
GRADE AT 2:1 SLOPE FROM
EDGE OF CONCRETE SWALE
TO DAYLIGHT
thughes02 Line thughes02 Line thughes02 Line
Polygon
Stanislaus National Forest Groveland Fire Station Section 27 T1S, R17E M.D.B.M
ISSUE DATE:
DRAWN BY:
CHECKED BY:
SCALE:
DRAWING:
PROJECT NO:
ZPG
15-06.09
DRAWING
11/12/15
KTQ
Gr ov ela nd
H ot sh ot s:
Of fic e an d
Ga ra ge Gr ov ela nd R an ge r S ta tio n
Hi gh wa y 1
Gr ov ela nd
, C ali fo rn ia
LEGEND
- PROTECTIVE SLOPE MATTING
- CONSTRUCTION ENTRANCE
- CONCRETE WASHOUT STRUCTURE
- STRAW WATTLE
- RIP-RAP DRAINAGE OUTLET PROTECTION
E. SITE
C6.0
EROSION CONTROL PLAN
Er os ion C on tro l P lan fo r:
1"=10'
NO
PARKING
NO
PARKING
SURFACE AS NOTED ON PLAN
GRAVEL BASE
4" CONCRETE SLAB w/ #3 RE-BAR
@ 18" O.C., E.W., TYPICAL
TYPICALSIDEWALK CONSTRUCTION: 4" CONCRETE SLAB,
w/ LIGHT BROOM FINISH, w/ #3 RE-BAR @18" O.C., E.W.
o/ 4" GRAVEL BASE o/ UNDISTURBED or 90% COMPACTED EARTH
8" WIDE THICKENED EDGE
w/ (1) #4 RE-BAR, CONT., TYPICAL
S
L
O
P
E
M a x
PREMOULDED EXPANSION JOINT FILLER
CONFORMING ASTM D1751 OT D1752
JOINT SEALER CONFORMING TO
ASTM D 1850 OR FED. SPEC. SS-S-1401
CONCRETE
PREMOULDED EXPANSION JOINT FILLER
CONFORMING ASTM D1751 OT D1752
JOINT SEALER CONFORMING TO
ASTM D 1850 OR FED. SPEC. SS-S-1401
CONCRETE
CONCRETE JOINT
CONCRETE / ASPHALT JOINT
ASPHALT
RAMP CROSS SLOPE PERPENDICULAR TO THE
DIRECTION OF TRAVEL MUST BE 2% OR LESS
8" THICK X 18" WIDE FOOTING WHERE CURB
HEIGHT > 32". MAX HEIGHT 36".
EXPANSION JOINT SEE DETAIL
#4 BARS AT 12" O/C MIN. (1) TOP/BOT.
HORIZ. & VERT AT 24" O/C WHEN CURB
HEIGHT > 32"
TYPICAL SIDEWALK CONSTRUCTION:
4" CONCRETE SLAB, w/ LIGHT BROOM FINISH, w/ #3 RE-BAR @ 18" O.C., E.W. o/ 4" SAND &
GRAVEL BASE o/ UNDISTURBED or 90%
COMPACTED EARTH
SLOPE AS NOTED ON PLAN
BUT SLOPE PERPENDICULAR
TO THE DIRECTION OF
TRAVEL MUST BE 2% OR
LESS
THICKENED
EDGE
CONCRETE CURB MINIMUM
DIMENSIONS SHOWN
THICKENED EDGE
* DOBIES
* DOBIES
* DOBIES - REFER TO NOTES SHEET C0.1
* DOBIES - REFER TO NOTES SHEET C0.1
#4 BARS AT 12" O/C MIN. (1)
TOP/BOT. HORIZ. & VERT AT 24"
O/C WHEN CURB HEIGHT > 32"
CONSTRUCT PER DETAIL 5,
THIS SHEET
* DOBIES - REFER TO NOTES SHEET C0.1
Pacific Southwest Region R5 USDA Forest Service
Stanislaus National Forest Groveland Fire Station Section 27 T1S, R17E M.D.B.M
ISSUE DATE:
DRAWN BY:
CHECKED BY:
SCALE:
DRAWING:
PROJECT NO:
ZPG
15-06.09
DRAWING
11/12/15
KTQ
Gr ov ela nd
H ot sh ot s:
Of fic e an d
Ga ra ge Gr ov ela nd R an ge r S ta tio n
Hi gh wa y 1
Gr ov ela nd
, C ali fo rn ia
E. SITE
C7.0
Stanislaus National Forest Groveland Fire Station Section 27 T1S, R17E M.D.B.M
ISSUE DATE:
DRAWN BY:
CHECKED BY:
SCALE:
DRAWING:
PROJECT NO:
ZPG
15-06.09
DRAWING
11/12/15
KTQ
Gr ov ela nd
H ot sh ot s:
Of fic e an d
Ga ra ge Gr ov ela nd R an ge r S ta tio n
Hi gh wa y 1
Gr ov ela nd
, C ali fo rn ia
3" THICK CONCRETE SURFACE PROTECTION AT
SHOULDER AND ON SLOPE ABOVE CONC. WALL
3" THICK CONCRETE SURFACE PROTECTION AT
SHOULDER AND ON SLOPE ABOVE CONC. WALL
STORM DRAIN TRENCH03
STORM DRAIN OUTLET
CONCRETE WASTE MANAGEMENT
PLAN
NTS
AA
TYPE "BELOW GRADE"
BERM
10 MIL
PLASTIC
LINING
10 FT MIN
V A
R I E
S
LATH AND
FLAGGING
ON 3 SIDES
BERM
10 MIL
PLASTIC
LINING
SANDBAG
BB
10 FT MIN
V A
R I E
S
10 MIL
PLASTIC
LINING
PLAN
NTS
TYPE "ABOVE GRADE"
WITH WOOD PLANKS
TWO-STAKED
2x12 ROUGH
WOOD FRAME
NOT TO SCALE
SECTION A-A
NOT TO SCALE
SECTION B-B
10 MIL PLASTIC LINING
WOOD FRAME
SECURELY
FASTENED AROUND
ENTIRE PERIMETER
WITH 2 STAKES
STAKE
(TYP)
2. THE CONCRETE WASHOUT SIGN SHALL BE INSTALLED WITHIN 30
1. ACTUAL LAYOUT DETERMINED IN THE FIELD
NOTES:
FEET OF THE TEMPORARY CONCRETE WASHOUT FACILITY
WHICHEVER IS GREATER
OF THE LARGEST CONSTRUCTION VEHICLE TIRE,
OR FOUR TIMES THE CIRCUMFERENCE
GRADE
EXISTING
MATCH
ORIGINAL
GRADE
B
B
NOTE:
NTS
PLAN
NTS
50 FT MIN
CULVERT AS NEEDED
E X
I S
T I N
G
P
A V
E D
R
O A
D W
A Y
DITCH
F
T
R
A
D
I
U
S
M
I
N
Construct sediment barrier and channelize runoff to sediment trapping device
12" MIN, UNLESS OTHERWISE
FILTER FABRIC
SECTION B-B
SPECIFIED BY A SOILS ENGINEER
BUT SMALLER THAN 6"
CRUSHED AGGREGATE GREATER THAN 3"
VEHICLE ENT/EXIT PROTECTION
CROSS-SECTION
ELEVATION VIEWPLAN VIEW
HORIZONTAL BARS AT 12" O/C TYPICAL
-- (1) AT TOP AND BOTTOM MINIMUM
-- (1) ABOVE AND BELOW INLET MINIMUM
SIDE WALLS TO FOLLOW ADJACENT SLOPE
VERTICAL BARS AT 12" O/C TYPICAL
HIGH DENSITY POLYEHTYLENE (HDPE) PIPE
REFER TO UTILITY PLAN FOR DIAMETER AND
TRENCH DETAIL FOR INSTALLATION REQUIREMENTS
DRAIN OUTLET WITH FLUSH SURFACE
RIP-RAP DISPERSION AT BASE OF
OUTLET 24" WIDE MINIMUM
SIDE WALLS TO FOLLOW ADJACENT SLOPE
HIGH DENSITY POLYEHTYLENE (HDPE)
PIPE REFER TO UTILITY PLAN FOR
DIAMETER AND TRENCH DETAIL FOR
INSTALLATION REQUIREMENTS
HIGH DENSITY POLYEHTYLENE (HDPE)
PIPE REFER TO UTILITY PLAN FOR
DIAMETER AND TRENCH DETAIL FOR
INSTALLATION REQUIREMENTS
RIP-RAP DISPERSION AT BASE OF
OUTLET 24" WIDE MINIMUM
SIDE WALLS TO FOLLOW ADJACENT SLOPE
2% SLOPE MIN.
18" Ø STEEL GRATE INLET
HORIZONTAL BARS AT 12" O/C TYPICAL
-- (1) AT TOP AND BOTTOM MINIMUM
-- (1) ABOVE AND BELOW INLET MINIMUM
SIDE WALLS TO FOLLOW ADJACENT SLOPE
VERTICAL BARS AT 12" O/C TYPICAL
(4) # 4 BARS CONTINUOUS IN FOOTING
(3) # 4 BARS CONTINUOUS IN FOOTING
CONCRETE DITCH SHAPED TO ENSURE WATER
FLOW AND CONFORM WITH RADIUS OF STORM
DRAIN AT INLET
OLDCASTLE DRAIN INLET STRUCTURE
CONCRETE INLET PROTECTION/
SUPPORT 3" THICK MINIMUM
SIDE WALLS TO FOLLOW ADJACENT SLOPE
CONCRETE DITCH SHAPED TO ENSURE WATER
FLOW AND RADIUS OF STORM DRAIN AT INLET
12"Ø HDPE STORM DRAIN PIPE
12"Ø HDPE STORM DRAIN PIPE
18" Ø STEEL GRATE INLET
CONCRETE DITCH SHAPE TO
ENSURE WATER FLOW AND
RADIUS OF STORM DRAIN AT INLET
SIDE WALLS TO FOLLOW ADJACENT SLOPE
GRAVEL SHOULDER
AC DIKE
ASPHALT SURFACE
ADJACENT SURFACE
PLAN VIEW
ELEVATION VIEW
CROSS-SECTION
STORM DRAIN INLET
SANDBAGS
VERTICAL & HORIZONTAL BARS AT 12" O/C TYPICAL
SPECIAL INSPECTION AND TESTING WILL BE PERFORMED IN ACCORDANCE WITH THE APPROVED PLANS
AND SPECIFICATIONS, THIS STATEMENT AND CBC SECTIONS 1704, 1705, 1707, AND 1708.
A FINAL REPORT OF SPECIAL INSPECTIONS DOCUMENTING REQUIRED SPECIAL INSPECTIONS, TESTING
AND CORRECTION OF ANY DISCREPANCIES NOTED IN THE INSPECTIONS SHALL BE SUBMITTED PRIOR
TO ISSUANCE OF A CERTIFICATE OF USE AND OCCUPANCY.
THIS PLAN HAS BEEN DEVELOPED WITH THE UNDERSTANDING THAT THE BUILDING OFFICIAL WILL:
- MONITOR SPECIAL INSPECTION ACTIVITIES ON THE JOB SITE TO ASSURE THAT THE SPECIAL
INSPECTORS ARE PERFORMING THEIR DUTIES AS CALLED FOR IN THIS STATEMENT
- REVIEW SUBMITTED INSPECTION REPORTS
- PERFORM INSPECTIONS AS REQUIRED BY THE LOCAL BUILDING CODE.
SPECIAL INSPECTOR: TO BE PROVIDED BY CONTRACTOR AND APPROVED
BY CONTRACTING OFFICER
VERIFICATION OF REQUIRED MIX DESIGN X
AT THE TIME FRESH CONCRETE IS SAMPLED TO
FABRICATE SPECIMENS FOR STRENGTH TESTS, X
PERFORM SLUMP AND AIR CONTENT TESTS,
AND DETERMINE THE TEMPERATURE OF THE
CONCRETE
INSPECTION ITEM: CONCRETE CONSTRUCTION CONTINUOUS PERIODIC
INSPECTION OF REINFORCING STEEL, INCLUDING
PRESTRESSING TENDONS, AND PLACEMENT X
SPECIAL INSPECTIONS
INSPECTION ITEM: SOIL VERIFICATION CONTINUOUS PERIODIC
VERIFY MATERIALS BELOW SHALLOW FOUNDATIONS X
ARE ADEQUATE TO ACHIEVE THE DESIGN BEARING
CAPACITY.
VERIFY EXCAVATIONS ARE EXTENDED TO PROPER X
DEPTH AND HAVE REACHED PROPER MATERIAL.
PERFORM CLASSIFICATION AND TESTING OF X
COMPACTED FILL MATERIALS.
VERIFY USE OF PROPER MATERIALS, DENSITIES, X
AND LIFT THICKNESSES DURING PLACEMENT AND
COMPACTION OF COMPACTED FILL.
PRIOR TO PLACEMENT OF COMPACTED FILL, X
OBSERVE SUBGRADE AND VERIFY THAT SITE
HAS BEEN PREPARED PROPERLY.
SPECIAL INSPECTOR: TO BE PROVIDED BY CONTRACTOR AND APPROVED
BY CONTRACTING OFFICER
VERTICAL & HORIZONTAL BARS AT 12" O/C TYPICAL
DETAILS
C7.2
AS NOTED
FIBER ROLL INSTALLATION
SEDIMENT FENCE
MATTING CHANNEL INSTALLATION05
MATTING SLOPE INTALLATION
STAPLE TABLE
09TREE PROTECTION06
RIP-RAP SLOPE PROTECTION
Rope
Plastic sheeting
Notes:
1) Minimum 12" overlap of all seams required.
2) Barrier required at toe of stock pile.
3) Covering maintained tightly in place by using sandbags or tires on ropes with a maximum 10' grid spacing in all directions.
Minimum 12" overlap of seams
Stock pile
Sandbag
Ground
Barrier required at toe of slope
PLASTIC SHEATHING / STOCK PILE PROTECTION
Notes:
1) Bury bottom of filter fabric 6" vertically below finished grade.
2) 2"x 2" fir, pine or steel fence posts.
3) Posts to be installed on uphill side of slope.
4) Compact both sides of filter fabric trench.
5) Unless otherwise noted on plans panels must be placed according to spacing table.
2'-6"
1'-6"
6"
6' Max. spacing
Post
FRONT VIEW
NTS
3' Min. from toe of slope
Use stitched loops over
2" X 2" posts
Filter fabric material 36" wide rolls
PROFILE
NTS
Angle filter fabric fence to assure soil is trapped
Interlocked 2" X 2" posts & attach
PLAN VIEW
NTS
10> % <15
Install parallel along contours as follows
% Slope Slope
10> % flatter 10:1 or flatter 300 ft.
10:1> X <7.5:1 150 ft.
100 ft.
50 ft.
25 ft.
7.5:1> X <5:1
5:1> X <3.5:1
3.5:1> X <2:1
15> % <20
20> % <30
30> % <50
4'-0"
2'-6"
6"
Max. spacing on slope
UNLESS OTHERWISE NOTED
PROTECTIVE
FENCING
TREE
TREE
Protective fencing at edge of critical root zone. No fencing required over hard surfaces
Critical root zone- see notes below to determine size
Sidewalk
Street
4' Min.
Zone of protection
6' Max. between stakes
Wood, chain link or orange poly construction fencing
FENCING DETAIL
Notes:
1) The critical root zone (CRZ) for trees 4" diameter or smaller shall be an area with a radius at least 5' from the trunk.
2) The CRZ for trees over 4" diameter shall be an area with a radius of at least 1'-6" from the trunk for every 1" of diameter size.
3) No soil grade changes or compaction shall take place within the CRZ except as directed.
4) No storage of material shall be allowed within the CRZ.
5) If work is done within the CRZ, care must be taken to minimize root disturbance. Special care shall be taken during excavation and removal of existing curb, gutter, and sidewalks to avoid damage to tree roots. Locate existing tree roots using hand tools or other approved methods such as an airspade.
6) Protective fencing is required when the work area is within the CRZ of trees, except where portions of the CRZ are covered with pavement such as streets or walks.
7) No root over 2" shall be cut without approval of the urban forester (or an approved arborist). Roots shall be cut with approved saws. No roots over 2" shall be cut or torn during trenching with power equipment such as backhoes and trenchers. Utility lines and irrigation or other pipes shall be installed by hand digging or tunneling under roots, as necessary, to avoid cutting roots 2" and larger.
TYPICAL TREE PROTECTION
(NO PAVED SURFACES)
TYPICAL STREET TREE
PROTECTION DETAIL
Planting strip
6' Metal 'T' fence stakes, typ.
Side and end overlap 6"
Notes:
1) On shallow slopes blankets may be applied across the slope.
2) All blanket staple required as Per table.
Extend blanket a minimum of
3' above crown of slope.
Staple edge 1' o.c.
Shallow Slopes 4:1 or Less
F l o w
F l o w
Bury top 4 inches of blanket and staple edge 1' o.c.
STEEP SLOPES 2:1 OR
GREATER
Moderate Slopes 3:1
Side & end overlap 6"
Bury top 12 inches of blanket in 6"x6" trench.
Staple bottom edge of blanket 1' o.c.
Side & overlap 6"
5%
Profile
NTS
6" Overlap (typ.)
6"
Ditch
Grade
Minimum Weir Depth
6 inch 12 inch 18 inch
6%
16 ft. o.c. 26 ft. o.c.
20 ft. 30 ft.
4%
26 ft.
40 ft.
3%
15 ft.
33 ft.
50 ft.
2% 25 ft. 50 ft.
80 ft.
Table 4-3 Spacing for Check Dams
B io filte r b a g
Refer to Table 4-3 for Spacing
F l o w
Notes:
1) Staking of bags required using (2) 1"x2" wood stakes or approved equal per bag.
2) Surface must be smooth before application.
PLAN VIEW
NTS
CHECK DAM - BIO FILTER BAG08
A B
D
A
A B
B
D
B
B
C
C
C
C ft
4:1 3:1 2:1
1:1 Low flow channel
MCI/High flow channel
1 staple per sq.
yd.
C
1 1/2 staples per sq. yd.
2 staples per
sq. yd.
3.5 staples per
sq. yd.
Staple Pattern
Length and Slope Table
Minimum Staple Pattern Guide & Recommendation for Slope &
Channel Application
3'
3'
3'
6'
6'
3'
3' 1
4' 4'
2'
4'
4'
2'
20"
Notes:
1) Information provided is minimum requirements.
Manufactures requirements which are more stringent shall be used.
2) Install mat parallel in center of channel in the direction of flow. For culvert outfalls, place at under culvert or rip rap a minimum of 12 inches.
3) In channel bottom, overlap length ends a minimum of
12 inches.
4) Refer to detail drawing for channel slope application.
5) Refer to detail Staple Table for staple pattern.
6) Length of staples shall be determined by soil type -cohesive soil use 6 inch, non-cohesive soils 8-12 inch.
CHANNEL INSTALLATION
F
L
O
W
PREPARED SCARIFIED
SURFACE
4" - 6" RIP RAP COBBLES
LARGER COBBLE KEYED
IN TO BASE OF SLOPE
Pacific Southwest Region R5 USDA Forest Service
Stanislaus National Forest Groveland Fire Station Section 27 T1S, R17E M.D.B.M
ISSUE DATE:
DRAWN BY:
CHECKED BY:
SCALE:
DRAWING:
PROJECT NO:
ZPG
15-06.09
DRAWING
11/12/15
KTQ
Gr ov ela nd
H ot sh ot s:
Of fic e an d
Ga ra ge Gr ov ela nd R an ge r S ta tio n
Hi gh wa y 1
Gr ov ela nd
, C ali fo rn ia
DETAILS
C7.3
AS NOTED
thughes02 Line thughes02 Typewritten Text
ASPHALT SHINGLE ROOF
thughes02 Typewritten Text
ASPHALT SHINGLE ROOF
thughes02 Typewritten Text
ASPHALT SHINGLE ROOF
thughes02 Polygon thughes02 Typewritten Text
(NIC)
thughes02 Line thughes02 Typewritten Text
ASPHALT SHINGLE ROOF
(NIC)
thughes02 Typewritten Text
(NIC)
thughes02 Typewritten Text
(NIC)
thughes02 Oval thughes02 Oval
Oval
(NIC)
thughes02 Typewritten Text
(NIC)
thughes02 Typewritten Text
(NIC)
thughes02 Oval thughes02 Oval
Oval thughes02 Line thughes02 Typewritten Text
FLOATED CONCRETE
thughes02 Typewritten Text
FLOATED CONCRETE
thughes02 Line thughes02 Typewritten Text
FLOATED CONCRETE
thughes02 Typewritten Text
FLOATED CONCRETE
WATER HEATER SCHEDULE
PLUMBING FIXTURE SCHEDULE
PLUMBING LEGEND
architect consultant
Mary McGrath Architects, Inc. | All Rights Reserved
2407.01 sheet title project no.
sheet no.
F:
\D ra w in gs
\1 5\
8.
\p lu m b\
8.
_P 1.
0.
d w g
N ov
1,
- 3
:3 0p m
505 17th STREET, SECOND FLOOR, OAKLAND, CA 94612 phone: 510.208.9400 | www.marymcgratharchitects.com
M 33,682
BR
A NDON RODGERS
MEC HA NICA L
EXP 6/30/17
RE
GI
ST
ER
ED PROFESSIONAL ENGINEER
S T A T E O F C A LIFORNIA
100 Cross Street, Ste 204
SLO, CA 93401
BMA JOB# 15188.00
OFF: (805) 544-4269
BMA Mechanical + client
USDA FOREST SERVICE
PACIFIC SOUTHWEST REGION R5
USDA - STF
GROVELAND
HOTSHOTS OFFICE
AND GARAGE
date description
GROVELAND RANGER STATION
24545 HIGHWAY 120
GROVELAND, CA 95321
project title sheet title
PLUMBING NOTES,
LEGEND, SCHEDULES
& ABBREVIATIONS
P1.0
PLUMBING ABBREVIATIONS
PLUMBING GENERAL NOTES
MANDATORY TITLE 24 MEASURES
UTILITY SIZING
PIPE MATERIALS
SERVICES LOCATION
DOMESTIC COLD
& HOT WATER
UNDERGROUND
ABOVE GROUND
MATERIAL
SCH. 40 PVC
COPPER (TYPE L)
SANITARY WASTE
SEWER
UNDERGROUND ABS
ABOVE GROUND ABS
SANITARY WASTE
VENT
ABOVE GROUND
ABS
CONDENSATE
DRAIN
ABOVE GROUND RIGID COPPER (TYPE M),
SCH. 40 PVC FOR HIGH
EFFICIENCY CONDENSING
EQUIPMENT
GAS
UNDERGROUND POLYETHYLENE (PE) PIPE OR
WRAPPED BLACK IRON
ABOVE GROUND SCH. 40 BLACK IRON
AutoCAD SHX Text
MANUAL FLUSH VALVE:
AutoCAD SHX Text
ZURN Z6000AV-HET
AutoCAD SHX Text
REMARKS
AutoCAD SHX Text
SIZE
AutoCAD SHX Text
FLUE
AutoCAD SHX Text
SIZE
AutoCAD SHX Text
BRANCH
AutoCAD SHX Text
MBTUH
AutoCAD SHX Text
KW
AutoCAD SHX Text
CY
AutoCAD SHX Text
PH
AutoCAD SHX Text
VOLTS
AutoCAD SHX Text
POWER
AutoCAD SHX Text
OUTLET
AutoCAD SHX Text
INLET/
AutoCAD SHX Text
WEIGHT
AutoCAD SHX Text
FULL
AutoCAD SHX Text
DIMENSIONS
AutoCAD SHX Text
CAPACITY
AutoCAD SHX Text
STORAGE
AutoCAD SHX Text
MODEL
AutoCAD SHX Text
MAKE
AutoCAD SHX Text
MARK
AutoCAD SHX Text
(INCHES)
AutoCAD SHX Text
(INCHES)
AutoCAD SHX Text
(INCHES)
AutoCAD SHX Text
(POUNDS)
AutoCAD SHX Text
(GALLONS)
AutoCAD SHX Text
FD-1
AutoCAD SHX Text
FLOOR DRAIN
AutoCAD SHX Text
W/ ROUND STRAINER
AutoCAD SHX Text
TRAP PRIMER
AutoCAD SHX Text
AutoCAD SHX Text 1-1/2
AutoCAD SHX Text 1/2
AutoCAD SHX Text
AutoCAD SHX Text
J.R. SMITH #2005-AP
AutoCAD SHX Text 5"%%C, AutoCAD SHX Text
PRECISION PLUMBING PRODUCTS
AutoCAD SHX Text
"PRIME-RITE" TRAP PRIMER
AutoCAD SHX Text
MIN. BRANCH SIZE (")
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
MARK
AutoCAD SHX Text W
AutoCAD SHX Text V
AutoCAD SHX Text
MAKE AND MODEL
AutoCAD SHX Text
HW
AutoCAD SHX Text
CW
AutoCAD SHX Text
FITTINGS
AutoCAD SHX Text
REMARKS
AutoCAD SHX Text
LT-1
AutoCAD SHX Text
LAUNDRY TUB
AutoCAD SHX Text
FLOOR MOUNTED
AutoCAD SHX Text
W/ VACUUM BREAKER
AutoCAD SHX Text
AutoCAD SHX Text 1-1/2
AutoCAD SHX Text 1/2
AutoCAD SHX Text 1/2
AutoCAD SHX Text
FLORESTONE #FM
AutoCAD SHX Text 23-1/8"x22-3/8"x35-1/2"
AutoCAD SHX Text
MOLDED STONE
AutoCAD SHX Text
ADA WATER CLOSET
AutoCAD SHX Text
ELONGATED, 1.28 GPF
AutoCAD SHX Text
FLOOR MOUNTED
AutoCAD SHX Text
VITREOUS CHINA, WHITE
AutoCAD SHX Text 28-3/4" x 14-1/2" x 17" RIM, AutoCAD SHX Text
ZURN #Z5665-BWL,
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 1-1/4
AutoCAD SHX Text
AutoCAD SHX Text
INSTALL PER ADA REQUIREMENTS,
AutoCAD SHX Text
LOCATE HANDLE ON WIDE SIDE OF FIXTURE
AutoCAD SHX Text
& ZURN SEAT #Z5955SS-EL,
AutoCAD SHX Text
WC-1
AutoCAD SHX Text
ADA LAVATORY
AutoCAD SHX Text
WALL MOUNT
AutoCAD SHX Text
ZURN #Z5344,
AutoCAD SHX Text 1/2
AutoCAD SHX Text 1-1/2
AutoCAD SHX Text
AutoCAD SHX Text
VITREOUS CHINA, WHITE
AutoCAD SHX Text 20"x 18"
AutoCAD SHX Text 1/2
AutoCAD SHX Text
STOPS, SUPPLIES, C.P. BRASS "P" TRAP,
AutoCAD SHX Text
INSTALL PER ADA REQUIREMENTS
AutoCAD SHX Text
& ZURN WALL SUPPORT Z1231
AutoCAD SHX Text L-1
AutoCAD SHX Text
ZURN FAUCET #Z-81104-XL-P-3M-PT-HCT W/GRID STRAINER,
AutoCAD SHX Text
MOEN HAND SHOWER,SLIDE BAR, GRAB BARS, SEAT,
AutoCAD SHX Text
FIBERGLASS
AutoCAD SHX Text
PRESSURE BALANCING
AutoCAD SHX Text
SHOWER
AutoCAD SHX Text 3/4
AutoCAD SHX Text
AutoCAD SHX Text 1-1/2
AutoCAD SHX Text
FLORESTONE #40-44,
AutoCAD SHX Text 40-1/2"x40-1/2" INSIDE, AutoCAD SHX Text
GEL COATED FIBERGLASS
AutoCAD SHX Text 3/4
AutoCAD SHX Text
CURTAIN ROD
AutoCAD SHX Text
RECESS UNIT FLUSH WITH FLOOR,
AutoCAD SHX Text
PROVIDE WITH PHENOLIC SEAT
AutoCAD SHX Text
SH-1
AutoCAD SHX Text
ADA SINGLE BOWL SINK
AutoCAD SHX Text
COUNTER TOP
AutoCAD SHX Text
ELKAY #DRKR2217,
AutoCAD SHX Text 1/2
AutoCAD SHX Text
AutoCAD SHX Text 1-1/2
AutoCAD SHX Text
18 GA. STAINLESS STEEL
AutoCAD SHX Text 16"x13"x7-5/8"
AutoCAD SHX Text 1/2
AutoCAD SHX Text
& C.P. BRASS "P" TRAP
AutoCAD SHX Text
STRAINER #LK35, STOPS, SUPPLIES
AutoCAD SHX Text
INSTALL PER ADA REQUIREMENTS
AutoCAD SHX Text
KS-1
AutoCAD SHX Text
CHICAGO FAUCET #1100-HA8AE35-317AB,
AutoCAD SHX Text
1.5 GPM
AutoCAD SHX Text
W/ VACUUM BREAKER
AutoCAD SHX Text
WALL MOUNT
AutoCAD SHX Text
HOSE BIBB
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
WOODFORD #17,
AutoCAD SHX Text
AutoCAD SHX Text
PROVIDE W/LOOSE TEE KEY
AutoCAD SHX Text
FREEZELESS WALL FAUCET
AutoCAD SHX Text
MOUNT 24" AFF
AutoCAD SHX Text
HB-1
AutoCAD SHX Text
W/HALF GRATE
AutoCAD SHX Text
FLOOR SINK
AutoCAD SHX Text
ENAMELED CAST IRON
AutoCAD SHX Text
J.R. SMITH #3100
AutoCAD SHX Text
AutoCAD SHX Text 1-1/2
AutoCAD SHX Text
AutoCAD SHX Text 10"x10"x6"
AutoCAD SHX Text
AutoCAD SHX Text
CAST IRON FLANGED RECEPTOR
AutoCAD SHX Text
FS-1
AutoCAD SHX Text
ACID RESISTANT COATED INTERIOR
AutoCAD SHX Text
W/ NICKEL BRONZE RIM
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
SYMBOL
AutoCAD SHX Text
ABBREV.
AutoCAD SHX Text
TPV
AutoCAD SHX Text
TRAP PRIMER VALVE
AutoCAD SHX Text
BALL VALVE
AutoCAD SHX Text
CD
AutoCAD SHX Text
CONDENSATE DRAIN
AutoCAD SHX Text
TEMPERATURE PRESSURE RELIEF VALVE
AutoCAD SHX Text T&P
AutoCAD SHX Text
HB
AutoCAD SHX Text
HOSE BIBB
AutoCAD SHX Text
COTG
AutoCAD SHX Text
CLEANOUT TO GRADE
AutoCAD SHX Text
UNION
AutoCAD SHX Text
PIPE DOWN
AutoCAD SHX Text
CAPPED/PLUGGED PIPE
AutoCAD SHX Text
AAV
AutoCAD SHX Text
AUTOMATIC AIR VENT
AutoCAD SHX Text
AAV
AutoCAD SHX Text
PRESSURE REDUCING OR REGULATOR VALVE
AutoCAD SHX Text
PRV
AutoCAD SHX Text
PLUG VALVE (PLAN VIEW)
AutoCAD SHX Text
PV
AutoCAD SHX Text
VALVE IN RISER
AutoCAD SHX Text
RECESSED HOSE BIBB
AutoCAD SHX Text
RHB
AutoCAD SHX Text
FCO
AutoCAD SHX Text
FLOOR CLEANOUT
AutoCAD SHX Text
WCO