A-11_Attachment_3_GovtFurnishedProperty.pdf
PDF 378 KB Posted
- Solicitation number
- AG-82MK-S-17-0021
About this file
Attachment 3 - Government Furnished Property
View the file
Other files
| File | Type | Posted |
|---|---|---|
| A-11_Attachment_1_Amend_1_Q&A.docx | DOCX document | |
| A-11_AG82MKS170021_Amend_1.pdf | ||
| A-11_Attachment_1-Specifications.pdf | ||
| A-11_Attachment_4_Wage_Determination.pdf | ||
| A-11_AG82MKS170021.pdf | ||
| A-11_Attachment_2_Drawings.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Silver Jack CG Water System Pressure Tank Installation
Government Furnished Property List
Quantity Item Condition & Current Estimated Value
Notes
3 Pentair Wellmate UT 80 fiberglass retention tanks
Used
Unit Value: $242
(New price was $364)
Stored at a government facility away from the project site. The government will deliver the tanks to the treatment building at project site before the Notice to Proceed is issued. If the Contractor wishes to delay delivery, they should contact the Contracting Officer.
See attached product data sheet. For typical dimensions. Piping and appurtenances required for installation are not furnished by the government.
1 Chem-Tech Series 100 diaphragm chemical injection pump (serial # 2007) and 30 gallon HDPE solution tank
Used
$200
Currently plumbed in treatment building at the project site.
See the Drawings for details on how the chemical injection pump is to be re-plumbed. Existing piping, tubing, and appurtenances in the treatment building may be reused. Additional piping, tubing and appurtenances required for installation are not furnished by the government.
FILTRATION & PROCESS WELLMATE UT SERIES RETENTION TANKS
Inlet/Outlet PVC Pipe Connections – allow straight through T connection on bottom of tank for ease of piping Blowdown Valve – for easy removal of sludge from bottom of tank Hydropneumatic Convertible – optional air volume control assembly and micronizer allow for quick and easy tank conversion Standard 1” ID / 1.25” Quick Connect Socket One piece, seamless inner shell molded of premium, high-density polyethylene which provides impact and corrosion resistance
Miles of fiberglass filament covered with epoxy resin produce superior strength in a light-weight design Additional drain port Curved bottom dome design maximizes contact time and facilitates sludge removal 1.25” socket inlet/outlet PVC pipe connections offer maximum application flexibility
FEATURES/BENEFITS
Contact Tank for Water Treatment Hydropneumatic
APPLICATIONS
WELLMATE® UT SERIES
UNIVERSAL RETENTION TANKS
There’s no better tank choice for water treatment than the Pentair® Wellmate® UT Series. Composite construction makes the entire line impervious to the chemicals found in aggressive water.
FILTRATION & PROCESS
5730 NORTH GLEN PARK ROAD, MILWAUKEE, WI 53209
262.238.4400, CUSTOMER CARE: 800.279.9404, WWW.PENTAIRAQUA.COM
All Pentair trademarks and logos are owned by Pentair, Inc. All other brand or product names are trademarks or registered marks of their respective owners.
Because we are continuously improving our products and services, Pentair reserves the right to change specifications without prior notice.
Pentair is an equal opportunity employer.
4003265 REV A MR14 © 2014 Pentair Residential Filtration, LLC. All Rights Reserved.
ORDERING INFORMATION
ACCESSORIES
FOR HYDROPNEUMATIC CONVERSION
PART # DESCRIPTION
CH3929-5 Micronizer
CH19426 Vacuum Breaker 1/4” NPT
CH20287 WM AVC ASSY QC HP7/HP110
CH20288 WM AVC ASSY QC HP8SQ/HP150SQ
CH20289 WM AVC ASSY QC HP9/HP150
CH20290 WM AVC ASSY QC HP18/HP300
CH20291 WM AVC ASSY QC HP26/HP450
NOTE: Flexible connectors must be installed between hard piping and tank openings. These pressure vessels are rated for an internal negative pressure of 5” HG (17 Pa) vacuum below atmospheric.If negative pressure could ever exceed 5” Hg (17 Pa), an adequate vacuum breaker must also be properly installed. Failure to install flex connection properly, or improper installation of a vacuum breaker when required, may void the warranty.
Tested and Certified by the Water Quality Association (WQA) to NSF/ANSI-61, Section 8 and NSF/ANSI 372.
QUICK CONNECT
MODEL
CAPACITY
GAL / LITER
MAXIMUM
OPERATING
PRESSURE
PSI / kPa / BAR
DIAMETER*
INCH / CM
OVERALL
HEIGHT*
INCH / CM
HEIGHT*
INLET/OUTLET
TO FLOOR
INCH / CM
SYSTEM CONNECTION ASSEMBLY
WEIGHT*
LB / KGTOP BOTTOM
UT-30 / WM-UT-110 / CE 30 / 114 75 / 500 / 5.0 16 / 41 44.5 / 113 1.5 / 3.8 1 1/4" Socket Q.C. 1 1/4" Socket 25 / 11.3
UT-40 / WM-UT-150 / CE 40 / 151 75 / 500 / 5.0 16 / 41 57.25 / 145 1.5 / 3.8 1 1/4" Socket Q.C. 1 1/4" Socket 28 / 12.7
UT-40SQ / WM-UT-150-SQ / CE 40 / 151 75 / 500 / 5.0 21 / 53 36 / 91 2 / 5.1 1 1/4" Socket Q.C. 1 1/4" Socket 33 / 15.0
UT-80 / WM-UT-300 / CE 80 / 303 75 / 500 / 5.0 21 / 53 62.75 / 159 2 / 5.1 1 1/4" Socket Q.C. 1 1/4" Socket 43 / 19.5
UT-120 / WM-UT-450 / CE 120 / 454 75 / 500 / 5.0 24 / 61 72.25 / 186 2 / 5.1 1 1/4" Socket Q.C. 1 1/4" Socket 63 / 28.6
NOTE: Maximum external operating temperature 120°F (49°C). Maximum internal operating temperature 100°F (38°C).
Minimum operating temperature 40°F (4°C).
*Diameter, height and weight may vary slightly without notice.
File details come from the government source that posted it. Updated .