221_222_225__Fencingreadable.pdf
PDF 98 KB Posted
- Attached to
- COUTINIOUS FENCING Federal contract opportunity
- Solicitation number
- AG-6197-S-16-0009
About this file
PDF drawings
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| A0005.pdf | ||
| A0004.rtf | RTF text file | |
| Current_Layout225.docx | DOCX document | |
| Specificaiton_changebldg_225.docx | DOCX document | |
| A0003sf30.rtf | RTF text file | |
| Current_Layout221222layout.docx | DOCX document | |
| bldg_221and222_change.docx | DOCX document | |
| A0002_q_and_a.rtf | RTF text file | |
| A0001_bid_opening.rtf | RTF text file | |
| SF1442.pdf | ||
| AG-6197-16-S-0009_sol.docx | DOCX document |
Show all 11
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Fence Bldgs. 221/222 22-Apr-16
Requirements
*Replace fencing - four lots (approximately 180 lineal feet per lot)
All materials must be rust, corrosion, and/or rot resistant.
All fencing and gates to be metal of sufficient strength to contain/withstand large adult cattle, horses, and bison
Fence Requirements:
Continuous metal fencing of sufficient strength to contain/withstand large adult cattle, horses, and/or bison
Metal posts NLT 2.875" diameter and 64" high, 3' in ground and NTE 6' apart wall thickness range .190 - .210 "
Horizontal bars NLT 1.75" in diameter wall thickness range no less than .140 inches
NLT 9 horizontal bars with spacing on center (from ground) of
4" (bottom), 10", 16", 22", 28", 34", 40", 52", 64" (top)
Wire fencing w/ spacing NTE 4" square to cover/secured to all continuous fence
- must cover from bottom rail to top rail
- must be sufficient/secure enough to prevent livestock of > 20# from entrapment
Gates - Placement as marked on Map (sizes approximate)
Sizes of 12' /10' (one each per lot plus an additional 10' per bldg.)
When hung gate clearance should be approximately 6" and top of gate should be NLT 58"
Bar spacing on gate must not exceed spacing of fence.
Gates to be able to swing 90 degree each way from a closed position
Spacing around gate NTE 4" on any side and NTE 2" on latch side
Remove and dispose of all wooden fence from each lot.
Assure postholes are filled/packed and area leveled to grade.
NADC will dispose of gates
Replace fencing for lots at buildings 221 and 222
Removal of Old Fence
Include 10' gate to
* Duplicate for Building 222 block alle
* each tick mark is about 2 feet
*eliminate alley separation and put in just one fence decreases overall fence length requirement by about 62 feet
Proposed changes to 221/222 fencing (same for each building) *eliminate alley between pens *Add requirement for 10 foot gate off southeast corner of east lot *reduce post dimension size requirement from 5" to 2.875"
East
West
Fence Bldg. 225 Animal Working Area 15-Aug-16
Requirements
All materials must be rust, corrosion, and/or rot resistant.
All fencing and gates to be metal of sufficient strength to contain/withstand large adult cattle, horses, and bison
Ground Requirements:
Install firm crushed rock/gravel base (average about 3") and level to grade
Horizontal Fence Requirements:
Continuous metal fencing of sufficient strength to contain/withstand large adult cattle, horses, and/or bison
Metal posts with thickness range .190-.210 inches and NLT 3" outside diameter.
Metal posts should be anchored in cement with 64" in height above ground, 3' in ground and NTE 6' apart.
Horizontal bars NLT 1.75" in diameter with thickness range no less than .140 inches
NLT 9 horizontal bars with spacing on center (from ground) of
4" (bottom), 10", 16", 22", 28", 34", 40", 52", 64" (top)
Solid Fence Requirements:
Continuous metal fencing of sufficient strength to contain/withstand large adult cattle, horses, and/or bison
Metal posts with thickness range .190-.210 inches and NLT 2.875" outside diameter
Metal posts should be anchored in cement with 64" in height above ground, 3' in ground and NTE 6' apart.
Horizontal bars NLT 1.75" in diameter with thickness range no less than .140 inches
NLT 6 horizontal bars with spacing on center (from ground) of 4" (bottom), 16", 28", 40", 52", 64" (top)
Solid metal panel (with thickness NLT .10 inches) welded to horizontal bars inside of chute/animal pens
Metal panel to have thickness NLT .10 inches and be welded to horizontal bars inside of chute/animal pens
Metal panel to NO sharp edges or protrusions that could potentially injure animals
Gates - Placement as marked on Map (size approximate)
Gates to be 12 feet
When hung gate clearance should be approximately 6" and top of gate should be NLT 58"
Bar spacing on gate must not exceed spacing of horizontal fence.
Gates to be able to swing 90 degree each way from a closed position
Spacing around gate NTE 4" on any side and NTE 2" on latch side
Roof to cover NLT 16 feet of east end of each pen
Clearance to top of west edge of roof NLT 9 feet with slope of roof to 8 feet at East end.
Replace fencing for building 225 animal working area
*Replace fencing with pipe continuous fence (approximately 280 lineal feet) and pipe reinforced solid fence (approximately 124 lineal feet)
Roof over three small holding pens (east side)
Fence posts to extend as roof support with NLT 3 posts per pen side and one post at rear center of pen (15 posts)
Roof support to include metal pipe attached to extended fence posts as follows:
NW corner to SW corner (4 posts)
Middle North to middle south (4 posts)
NE corner to SE corner (4 posts)
Roof Sheeting to be heavy gauge corrigated metal
East side of roof to include rain gutter with attached downspout at Southeast corner
Remove and dispose of all wooden fence as indicated (approximately 300 feet)
Assure postholes are filled/packed
NADC will dispose of gates
Removal of Old Fence
Current Layout
Brown = Wood fence for removal
* Each tick mark is four feet
New Layout Proposed
= Extended posts = Gate Hinge side Red = Gates (16-12 Ft.) Blue = Pipe Fence (about 224 Ft.) Green = Solid Fence (about 180 ft.) Orange = Existing Fence
222 East
221 West 221 East 222 West 222 East
Portable tub
221 West 221 East 222 West
| Specifications 221-222 |
| 221-222 layout |
| Specifications 225 |
| 225 layout |
File details come from the government source that posted it. Updated .