BathhousePlans.pdf
PDF 2 MB Posted
- Attached to
- Site Improvements, Trout Pond Recreation Area Federal contract opportunity
- Solicitation number
- AG-3395-S-15-0014
About this file
Trout Pond Bath House Replacement Plans
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Trout_Pond_SHT3_Water_Tank.pdf | ||
| Trout_Pond_SHT_1-Site_Plan.pdf | ||
| Amendment_2.pdf | ||
| Amendment_1.pdf | ||
| Trout_Pond_Water_System_Pics1.docx | DOCX document | |
| AlarmHornLightCS_AV1-LED_0713.pdf | ||
| Trour_Pond_3_Panel_Info_Board.pdf | ||
| Sign_in_Sheets.pdf | ||
| SF1442_Revised.pdf | ||
| Submittal_Copy.pdf | ||
| TroutPondWaterSystemSpecsFinal_(2).pdf | ||
| OF-17 _bid_sticker.pdf | ||
| TroutPondFinalContractDrawings12-14-ALL_SHEETS.pdf | ||
| SF_24 _Bid_Bond.pdf | ||
| Trout_Pond_Bathhouse_Specs_final.pdf | ||
| AG3395S150014.pdf |
Show all 16
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
INFRA SITE No. INFRA BLDG. No. REAL PROPERTY No.
REC. SITE No.
LEE
RANGER DISTRICT
TROUT POND RECREATION AREA
BATH HOUSE REPLACEMENT
DEMOLITION PLAN
LEE
RANGER DISTRICT
TROUT POND RECREATION AREA
BATH HOUSE REPLACEMENT
SITE PLAN
LEE
RANGER DISTRICT
TROUT POND RECREATION AREA
BATH HOUSE REPLACEMENT
PLUMBING DETAIL
REC. SITE No.
LEE
RANGER DISTRICT
TROUT POND RECREATION AREA
BATH HOUSE REPLACEMENT
PAD AND SIDEWALK DETAIL
NOTES:
1. DO NOT SCALE DRAWINGS.
2. INSTALL ACCORDING TO MANUFACTURER'S SPECIFICATIONS.
3. INSTALL USING OPTIONAL STAINLESS STEEL SURFACE CARRIER.
4. SHOWER PEDESTAL COLOR TO BE POWDER COATED, SMOOTH BROWN FINISH.
5. CUSTOM DRAWING MUST ACCOMPANY ORDER.
ACCESS DOOR
QUICK CLOSE VALVE
METERED VALVE
GRAB BAR
565 SM ADA SHOWER
SHOWN W/ OPTIONAL 8" S.S. SURFACE CARRIER
ACCESS
DOOR
8" SS PIPE
HANDICAP HEIGHT
HANDICAP HEIGHT METERED
1/2" X 12" ZINC
PLATED ROD
FULL HEIGHT
QUICK CLOSING
METERED
3/8" NYLON REINFORCED
NYLONBRAID TUBING W/ 1/2" MIP
(WATER SUPPLY)
1/2" X 12" ZINC
PLATED ROD
SIDE VIEW FRONT VIEW
6. SHOWER DRAINS SHALL BE PLACED AS STAKED AND CONCRETE
8. CONCRETE SHALL BE 3000 PSI WITH WELDED WIRE MESH
SHALL BE SLOPED 1/4" PER FOOT TO DRAIN.
7. PROVIDE A VALVE IN A VALVE BOX ON THE SUPPLY LINE.
9. COR WILL STAKE THE LOCATION OF THE SHOWER TOWERS.
REINFORCEMENT. STIFF BROOM FINISH. SLOPED TO DRAIN.
10. DRAIN SHALL BE 3" SCHEDULE 40 PVC FOR BOTH SHOWERS.
11. DRAIN OUTLETS SHALL BE COVERED 1/4 X 1/4 GALVANIZED HARDWARE CLOTH
WITH A STAINLESS STEEL BAND.
FOOT HEIGHT
12. THIS DRAWING IS INTENDED FOR PLANNING PURPOSES ONLY AND MUST NOT
BE USED FOR CONSTRUCTION.
8" S.S. SURFACE CARRIER
13. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOP-
MENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT MANUFACTURER
TO BE CONSIDERED ACCURATE.
PEDESTAL COLOR TO BE POWDER
COATED, SMOOTH BROWN FINISH
NOTES:
1. SLOPE CONCRETE DRAIN 1/4" PER FOOT.
2. STIFF BROOM FINISH.
3. 5" THICK 3000 PSI CONCRETE SLAB WITH WELDED WIRE MESH
4. 6" CRUSHED ROCK COMPACTED AGGREGATE SUB BASE ON
COMPACTED SUBGRADE.
SLOPE 3 " DRAIN 1/4" PER FOOT (MIN) TO DAYLIGHT OR SANITARY SEWER.
3 INCH SWEEP ELBOW
5 INCH DRAIN BASIN
WITH PERFORATED COVER
INFRA SITE No. INFRA BLDG. No. REAL PROPERTY No.
REC. SITE No.
LEE
RANGER DISTRICT
TROUT POND RECREATION AREA
BATH HOUSE REPLACEMENT
OUTSIDE SHOWER DETAIL