Atch_2_-_Drawings.pdf
PDF 2 MB Posted
- Attached to
- Fire Cache Fire Sprinkler and Alarm System Upgrade Federal contract opportunity
- Solicitation number
- AG-04GG-S-17-0010
About this file
Drawings
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| SF-30_-_Amd_2_-_AG-04GG-S-17-0010_.pdf | ||
| HVAC_Upgrade_As-Builts.pdf | ||
| Conformed_AG-04GG-S-17-0010_Amd_0001.pdf | ||
| Site_Visit_Handout.pdf | ||
| Minutes_from_site_visit.pdf | ||
| SF-30_-_Amd_1_-_AG-04GG-S-17-0010.pdf | ||
| Balance_Report_2014-01-24.pdf | ||
| Atch_3_-_Wage_Decision_OR170025.pdf | ||
| Atch_1_-_Specifications.pdf | ||
| AG-04GG-S-17-0010.pdf | ||
| Atch_5_Past_Performance_Data_Sheet.docx | DOCX document | |
| Atch_4_Fire_clauses_r6-fs-6300-52.pdf |
Show all 12
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
REDMOND AIR CENTER FIRE CACHE
FIRE SPRINKLER AND ALARM SYSTEM
UPGRADE
Case, Lowe and Hart, Inc.
2484 Washington Blvd. Ste 510
Ogden, Utah 84401
DRAWING INDEX
G001 Title Sheet FP101 Fire Sprinkler Demolition Plan − Cache Warehouse FP102 Schematic Fire Sprinkler Plan − Cache Warehouse FP103 Fire Alarm Demolition Plan − Cache Warehouse FP104 Fire Alarm Plan − Cache Warehouse
Protection Consultants, Inc.
1199 S Main Street #101
Centerville, Utah 84014
U. S. Department of Agriculture
FOREST SERVICE
Pacific Northwest Region Six Engineering
DESCHUTES NATIONAL FOREST
17674
RPE
S R
OF
ER ES
L E
K
V
NI J. E W
IS
EG
I
T
D
SIONA
L
IGNE
NEER
OREGON
14,R.
A
M
1 99 5
Case, Lowe & Hart, Inc. 2484 Washington Blvd.
Suite 510 Ogden, Utah 84401
801.399.5821 Fax 801.399.0728 www.clhae.com
SHEET OF 5
DRAWN BY:
CHECKED BY:
REDMOND AIR CENTER FIRE
CACHE FIRE SPRINKLER AND
ALARM SYSTEM UPGRADE
DESCHUTES
PACIFIC NORTHWEST
DISTRICT RANGER
ISSUE INFORMATION
PROJECT NO:
CAD DWG FILE:
DESIGNED BY:
15072
F0REST SUPERVISOR
FOREST ENGINEER
DATE
DATE
DATE
AGRICULTURE
The Pacific Northwest Region
FOREST SERVICE
UNITED STATES
DEPARTMENT
OF
PROJECT TEAM
Protection Consultants, Inc.
1199 S. Main Street #101 Centerville, Utah 84014
801.295.6070 Fax 801.677.0000
NATIONAL FOREST
REGION 6
NOV 01, 2016
MARK DATE DESCRIPTION
G001
Title Sheet
K.J.L.
J.A.C., J.M.S.
K.J.L.
G001.DWG
11/01/16
FIRE SPRINKLER DEMO KEY NOTES
CONNECTED TO NEW RISER.
CONNECTION PIPING MAY REMAIN TO BE
MAIN DRAIN (IF 2") AND FIRE DEPARTMENT
PIPING BACK TO 6" FLANGE ABOVE FLOOR SLAB.
VALVES GAUGES AND APPURTENANCES. REMOVE
DEMOLISHED. REMOVE ALL PIPING, FITTINGS,
EXISTING FIRE SPRINKLER RISER TO BE
SUPPORTS AND BRACES.
DEMOLISHED. REMOVE PIPING, FITTINGS, PIPE
EXISTING 2-1/2" FEED AND CROSS MAINS TO BE
AND PIPE SUPPORTS.
DEMOLISHED. REMOVE PIPING, FITTINGS, SPRINKLERS
SPRINKLERS PROTECTING WAREHOUSE AREA TO BE
EXISTING 1-1/4" BRANCH LINES AND UPRIGHT FIRE
FEED MAIN (SEE SHEET FP102).
CONNECT PIPING TO NEW FIRE SPRINKLER RISER OR
PROTECTING EAST OFFICE/WORK AREAS TO REMAIN.
EXISTING FIRE SPRINKLERS AND BRANCH LINES
FP101
FP101.DWG
2-1/2" 2-1/2" 2-1/2" 2-1/2"
2-1/2"
2-1/2"2-1/2"2-1/2"2-1/2"
1 0
FIRE SPRINKLER DEMOLITION PLAN - CACHE WAREHOUSE
1/8" = 1’-0" 4’ 8’ 16’
Cache Warehouse Demolition Plan -
Fire Sprinkler
PUMP REPAIR
PUMP REPAIR
W A
R E
H O
U S
E
TOOL MAINTENANCE
MECHANICAL
PAINTING
OVEN REPAIR MEN
WOMEN
OFFICE
OFFICE
OFFICE
OFFICE
Case, Lowe & Hart, Inc. 2484 Washington Blvd.
Suite 510 Ogden, Utah 84401
801.399.5821 Fax 801.399.0728 www.clhae.com
SHEET OF
DRAWN BY:
CHECKED BY:
DESCHUTES
PACIFIC NORTHWEST
DESCRIPTION
DISTRICT RANGER
ISSUE INFORMATION
PROJECT NO:
CAD DWG FILE:
DESIGNED BY:
MARK DATE
F0REST SUPERVISOR
FOREST ENGINEER
DATE
DATE
DATE
AGRICULTURE
The Pacific Northwest Region
FOREST SERVICE
UNITED STATES
DEPARTMENT
OF
PROJECT TEAM
Protection Consultants, Inc.
1199 S. Main Street #101 Centerville, Utah 84014
801.295.6070 Fax 801.677.0000
NATIONAL FOREST
REGION 6
GTJ
BAJ
GTJ
11/01/16
15072
ALARM SYSTEM UPGRADE
CACHE FIRE SPRINKLER AND
REDMOND AIR CENTER FIRE
11/01/16
3 3
FIRE SPRINKLER KEY NOTES
FIRE SPRINKLER GENERAL NOTES
FLOW: 804 GPM
RESIDUAL PRESSURE 122 PSI
STATIC PRESSURE: 148 PSI
FLOW TEST AND FIRE PUMP SUBMITTAL DATA) IS:
PUMP DISCHARGE FLANGE (BASED ON OCT 2014
FIRE PROTECTION WATER SUPPLY AVAILABLE AT
FROM ADJACENT FIRE PUMP HOUSE TO REMAIN.
REMOTE, FREE STANDING POST INDICATOR VALVE
EXISTING 6" FIRE PROTECTION WATER SUPPLY WITH
SHEET.
WATER FLOW SWITCH. SEE RISER DETAIL ON THIS
VALVE, 2" MAIN DRAIN, PRESSURE GAUGES AND
NEW, 6" FIRE SPRINKLER RISER WITH RISER CHECK
SHEET.
TO RISER. SEE FIRE SPRINKLER RISER DETAIL ON THIS
CHECK VALVE WITH AUTOMATIC BALL DRIP FROM FDC
RISER CHECK VALVE. INSTALL NEW 4" PIPING AND
FDC TO NEW FIRE SPRINKLER RISER DOWNSTREAM OF
CONNECTION (FDC) TO REMAIN. CONNECT EXISTING
EXISTING, 2-WAY, WALL MOUNTED FIRE DEPARTMENT
MAIN.
PROTECTING OFFICE/WORK AREAS TO NEW 6" FEED
CONNECT EXISTING PIPING FOR FIRE SPRINKLERS
INSTALLED THROUGHOUT WAREHOUSE AREA.
WAREHOUSE AREA TO SUPPLY NEW FIRE SPRINKLERS
INSTALL NEW 6" FEED MAIN FROM NEW RISER TO
REMAIN.
OFFICE/WORK AREAS EAST OF WAREHOUSE TO
EXISTING FIRE SPRINKLERS/PIPING PROTECTING
PLATFORMS.
SPACES IN WAREHOUSE AND BELOW STORAGE
ON PLANS) TO PROTECT BELOW CEILING OF OFFICE
INSTALL ADDITIONAL FIRE SPRINKLERS (NOT SHOWN
SPRINKLERS.
MULTIPLE ROW RACKS WITHOUT IN-RACK FIRE
COMMODITY STORED ON SINGLE, DOUBLE OR
HIGH STORAGE OF NON-ENCAPSULATED CLASS IV
16.2.1.3.3.2 AND FIGURE 16.2.1.3.2(D) CURVE C FOR 15’
BASED ON THE REQUIREMENTS OF NFPA 13 TABLE
PROVIDE 500 GPM HOSE ALLOWANCE). DESIGN IS
SYSTEM LACKS SUFFICIENT VOLUME AT RAC TO
HOSE ALLOWANCE IS REQUIRED (REDMOND WATER
DENSITY OF 0.385 GPM/SQ FT OVER 2,000 SQ FT. NO
HYDRAULIC DESIGN AREA #1. MINIMUM DISCHARGE
1.
C. USFS DESIGN STANDARDS
2013 EDITION
B. NFPA 13 INSTALLATION OF FIRE SPRINKLER SYSTEMS
A. INTERNATIONAL BUILDING/FIRE CODES (2015 EDITIONS)
FOLLOWING CODES AND STANDARDS:
COMPLY WITH THE APPLICABLE PROVISIONS OF THE
THE FIRE SPRINKLER SYSTEM SHALL BE DESIGNED TO
2.
HAVING JURISDICTION.
CALCULATIONS AND OBTAIN APPROVAL FROM AUTHORITY
SPRINKLER SYSTEM, PREPARE SHOP DRAWINGS, HYDRAULIC
CONDITIONS, DEVELOP THE FINAL DESIGN FOR FIRE
SHALL BE RESPONSIBLE TO FIELD VERIFY EXISTING
BUILDING CONDITIONS. THE FIRE SPRINKLER CONTRACTOR
MUST BE ADJUSTED WHERE REQUIRED TO MATCH ACTUAL
OTHER FIRE PROTECTION EQUIPMENT ARE APPROXIMATE AND
SHOWN ON THESE DRAWINGS FOR SPRINKLERS, PIPING AND
THIS DRAWING IS CONCEPTUAL IN NATURE. THE LOCATIONS
THE DESIGN OF THE FIRE SPRINKLER SYSTEM CONTAINED ON
3.
ACCORDANCE WITH THE DRAWINGS AND SPECIFICATIONS.
2013 EDITION, REDMOND FIRE DEPARTMENT AND SHALL BE IN
DESIGN SHALL MEET THE REQUIREMENTS OF IBC, IFC, NFPA 13
REDMOND AIR CENTER IN REDMOND, OR. THE SYSTEM
PROTECT ALL AREAS OF CACHE WARESHOUSE AT THE
FUNCTIONAL A NEW WET-PIPE FIRE SPRINKLER ZONE TO
PERFORM ALL WORK AND OPERATIONS TO INSTALL AND MAKE
FURNISH ALL MATERIALS, EQUIPMENT AND SUPPLIES AND
4.
COVERAGE PER SPRINKLER SHALL BE 100 SQ FT.
ORIFICE (K-11.2) HIGH TEMPERATURE RATED. MAXIMUM
FIRE SPRINKLERS IN WAREHOUSE SHALL BE EXTRA LARGE
5.
DRAWINGS
BY THE FIRE ALARM SYSTEM. REFER TO FIRE ALARM
CONTROL VALVES AND FLOW SWITCHES SHALL BE PROVIDED
OFF-PREMISE SUPERVISION OF ALL FIRE SPRINKLER SYSTEM
6.
SYSTEMS.
AND/OR FM APPROVED FOR USE IN FIRE PROTECTION
OF THE FIRE SPRINKLER SYSTEM SHALL BE U.L. LISTED
ALL DEVICES AND MATERIALS USED FOR THE INSTALLATION
7.
SHALL BE DOMESTIC, BLACK STEEL, SCHEDULE 40 PIPING.
CONFORMING TO ANSI/ASTM A53, ASTM A135 OR A795. PIPING
NEW FIRE SPRINKLER PIPING SHALL BE STEEL PIPE
8.
C. PLAIN END FITTINGS MAY NOT BE USED.
GASKETED VICTAULIC STYLE FITTINGS AND COUPLINGS.
JOINED WITH CUT/ROLL GROOVED JOINTS USING RUBBER
B. PIPING 2-1/2" AND LARGER IN NOMINAL DIAMETER SHALL BE
AND COUPLINGS.
JOINED WITH THREADED JOINTS USING CAST IRON FITTINGS
A. PIPING 2" AND SMALLER IN NOMINAL DIAMETER SHALL BE
FITTINGS:
9.
PIPE AND MAXIMUM 15’-0" BETWEEN HANGERS.
1-1/2" AND LARGER: MINIMUM ONE HANGER PER LENGTH OF
OF PIPE AND MAXIMUM 12’-0" BETWEEN HANGERS.
1-1/4" AND SMALLER PIPE: MINIMUM ONE HANGER PER LENGTH
HANGERS:
10.
CROSS MAINS.
ALL FIRE SPRINKLER SYSTEM RISERS, FEED MAINS AND
INSTALL SWAY BRACING IN ACCORDANCE WITH NFPA 13 ON
SWAY BRACING:
11.
FABRICATING OR INSTALLING ANY EQUIPMENT.
ENGINEER AND THE GOVERNMENT PRIOR TO ORDERING,
WITH NFPA 13 FOR REVIEW AND APPROVAL TO THE PROJECT
DRAWINGS AND HYDRAULIC CALCULATIONS IN ACCORDANCE
CONTRACTOR SHALL PREPARE AND SUBMIT COMPLETE SHOP
12.
FOREST SERVICE AND REDMOND FIRE DEPARTMENT.
TESTING SHALL BE WITNESSED AND APPROVED BY THE US
ANDRECOMMENDED BY EQUIPMENT MANUFACTURERS. ALL
COMMISSIONING REQUIRED BY NFPA 13, NFPA 20 AND NFPA 72
CONTRACTOR SHALL PERFORM ALL TESTING AND
1 01/8" = 1’-0" 4’ 8’ 16’
PUMP REPAIR
PUMP REPAIR
W A
R E
H O
U S
E
TOOL MAINTENANCE
MECHANICAL
PAINTING
OVEN REPAIR MEN
WOMEN
OFFICE
OFFICE
OFFICE
OFFICE
FP102
SCHEMATIC FIRE SPRINKLER PLAN - CACHE WAREHOUSE Cache Warehouse Sprinkler Plan - Schematic Fire
D
567891011121314
15 16 17 18 19 20 21 22 23 24 25 26 27 28
29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52
103 106
108 113
4" 4" 4" 4" 4" 4" 4" 4" 4" 4" 4" 4" 4" 4" 4" 4" 4" 4" 4" 4" 4" 4" 4" 4" 1- 1/ x
1’
1- 1/ x
1’
1- 1/ x
1’
1- 1/ x
1’
1- 1/ x
1’
1- 1/ x
1’
1- 1/ x
1’
1- 1/ x
1’
1- 1/ x
1’
1- 1/ x
1’
1- 1/ x
1’
1- 1/ x
1’
1- 1/ x
1’
1- 1/ x
1’
1- 1/ x
1’
1- 1/ x
1’
1- 1/ x
1’
1- 1/ x
1’
1- 1/ x
1’
1- 1/ x
1’
1- 1/ x
1’
1- 1/ x
1’
1- 1/ x
1’
1- 1/ x
1’
1- 1/ x
1’
1- 1/ x
1’
1- 1/ x
1’
1- 1/ x
1’
1- 1/ x
1’
1- 1/ x
1’
1- 1/ x
1’
1- 1/ x
1’
1- 1/ x
1’
1- 1/ x
1’
1- 1/ x
1’
1- 1/ x
1’
1- 1/ x
1’
1- 1/ x
1’
1- 1/ x
1’
1- 1/ x
1’
1- 1/ x
1’
1- 1/ x
1’
1- 1/ x
1’
1- 1/ x
1’
1- 1/ x
1’
1- 1/ x
1’
1- 1/ x
1’
1- 1/ x
1’
3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3"
FIRE SPRINKLER RISER SCHEMATIC
D
NO SCALE
SUPPLY FROM PUMP HOUSE TO REMAIN
EXISTING 6" FIRE PROTECTION WATER
TO REMAIN
EXISTING 6" FLANGE ABOVE FLOOR SLAB
WITHIN 24" OF FLOOR
NEW 6" RISER WITH FLEXIBLE COUPLING
OUTLET AND PRESSURE GAUGES.
RISER CHECK VALVE WITH MAIN DRAIN
PIPING MAY BE REUSED.
BUILDING EXTERIOR. EXISTING DISCHARGE
2" MAIN DRAIN. EXTEND DISCHARGE TO
12 SPRINKLERS
SPARE SPRINKLER CABINET. STOCK WITH
4" SWING CHECK VALVE
DRAINAGE
DRIP AT LOW POINT OF PIPING FOR
BE REUSED. PROVIDE 1/2" AUTO BALL
DEPT. CONNECTION. EXISTING FDC MAY
4" OUT TO 2-1/2" X 2-1/2" X 4" FIRE
HYDRAULIC DESIGN INFORMATION PLACARD
VANE TYPE WATER FLOW SWITCH
PIPING.
THROUGH 2" MAIN DRAIN DISCHARGE
DISCHARGE TO EXTERIOR OF BUILDING
PRESSURE RELIEF VALVE. EXTEND
VALVE WITH 1/2" ORIFICE AND BUILT-IN
AGF MODEL 3011 INSPECTOR’S TEST
6" SUPPLY TO FIRE SPRINKLER SYSTEM
FP102.DWG
Case, Lowe & Hart, Inc. 2484 Washington Blvd.
Suite 510 Ogden, Utah 84401
801.399.5821 Fax 801.399.0728 www.clhae.com
SHEET OF
DRAWN BY:
CHECKED BY:
DESCHUTES
PACIFIC NORTHWEST
DESCRIPTION
DISTRICT RANGER
ISSUE INFORMATION
PROJECT NO:
CAD DWG FILE:
DESIGNED BY:
MARK DATE
F0REST SUPERVISOR
FOREST ENGINEER
DATE
DATE
DATE
AGRICULTURE
The Pacific Northwest Region
FOREST SERVICE
UNITED STATES
DEPARTMENT
OF
PROJECT TEAM
Protection Consultants, Inc.
1199 S. Main Street #101 Centerville, Utah 84014
801.295.6070 Fax 801.677.0000
NATIONAL FOREST
REGION 6
GTJ
BAJ
GTJ
11/01/16
15072
ALARM SYSTEM UPGRADE
CACHE FIRE SPRINKLER AND
REDMOND AIR CENTER FIRE
11/01/16
1’-0" BD
1’-0" BD
2’-6" BD
2’-6" BD
2’-6" BD2’-6" BD
AND FACP.
SWITCH AND ALL WIRING BETWEEN FLOW SWITCH
SWITCH TO BE DEMOLISHED. REMOVE FLOW
EXISTING FIRE SPRINKLER RISER WITH WATER FLOW
FACP.
BETWEEN FIRE SUPPRESSION SYSTEM CONTROLS AND
REMOVE ALL WIRING, J-BOXES, CONDUIT AND WIRING
EXISTING FIRE ALARM SYSTEM TO BE DEMOLISHED.
FIRE SUPPRESSION SYSTEM CONTROLS FROM
TO REMAIN. DISCONNECT ACTIVATION RELAYS OF
EXISTING FIRE SUPPRESSION SYSTEM IN FUME HOOD
SAMPLING TUBE, J-BOXES, CONDUIT AND WIRING.
DEMOLISHED. REMOVE DETECTOR, HOUSING,
EXISTING DUCT MOUNTED SMOKE DETECTOR TO BE
NEW FIRE ALARM SYSTEM (SEE SHEET FP104).
AND FAN CONTROLS MAY REMAIN TO BE REUSED FOR
BETWEEN RELAY AND FACP. WIRING BETWEEN RELAY
DEMOLISHED. REMOVE RELAY AND ALL WIRING
EXISTING RELAY FOR FAN SHUTDOWN TO BE
FIRE ALARM DEMOLITION KEY NOTES
SYSTEM HAS BEEN INSTALLED AND TESTED.
SYSTEM TO OCCUR ONLY AFTER NEW FIRE ALARM
PHASE DEMOLITION OF EXISTING FIRE ALARM
BOXES (EXCEPT AS NOTED BELOW) AND WIRING.
NOTIFICATION APPLIANCES, CONDUIT, JUNCTION
POWER SUPPLIES, INITIATING DEVICES,
ENTIRETY. REMOVE ALL CONTROL EQUIPMENT,
CONVENTIONAL FCI) TO BE DEMOLISHED IN ITS
EXISTING FIRE ALARM SYSTEM (6 ZONE
PULL STATION (SEE SHEET FP104).
PRESENT) MAY REMAIN IF REUSED TO MOUNT NEW
AND WIRING. J-BOXES AND CONDUIT (WHERE
DEMOLISHED. REMOVE DEVICE, J-BOXES, CONDUIT
EXISTING FIRE ALARM PULL STATION TO BE
PRESENT) AND WIRING.
DEMOLISHED. REMOVE DEVICE, J-BOX, CONDUIT (IF
EXISTING SMOKE OR HEAT DETECTOR TO BE
ALARM SYSTEM (SEE SHEET FP104).
CONTROLS MAY REMAIN TO BE REUSED FOR NEW FIRE
FACP. WIRING BETWEEN RELAY AND EXHAUST FAN
REMOVE RELAY AND ALL WIRING BETWEEN RELAY AND
VERIFIED BY CONTRACTOR) TO BE DEMOLISHED.
(PURPOSE OF RELAY IS ASSEUME AND SHALL BE
EXISTING RELAY FOR EXHAUST FAN ACTIVATION
NOTIFICATION APPLIANCE (SEE SHEET FP104).
PRESENT) MAY REMAIN IF REUSED TO MOUNT NEW
AND WIRING. J-BOXES AND CONDUIT (WHERE
DEMOLISHED. REMOVE DEVICE, J-BOXES, CONDUIT
EXISTING FIRE ALARM NOTIFICATION APPLIANCE TO BE
1 01/8" = 1’-0" 4’ 8’ 16’
PUMP REPAIR
PUMP REPAIR
W A
R E
H O
U S
E
TOOL MAINTENANCE
MECHANICAL
PAINTING
OVEN REPAIR MEN
WOMEN
OFFICE
OFFICE
OFFICE
OFFICE
FIRE ALARM DEMOLITION PLAN - CACHE WAREHOUSE
FP103
Cache Warehouse Demolition Plan -
Fire Alarm
F
SD
SD
M
R
R
FP103.DWG
STORAGE
F A
P S
F A
C P
Case, Lowe & Hart, Inc. 2484 Washington Blvd.
Suite 510 Ogden, Utah 84401
801.399.5821 Fax 801.399.0728 www.clhae.com
SHEET OF
DRAWN BY:
CHECKED BY:
DESCHUTES
PACIFIC NORTHWEST
DESCRIPTION
DISTRICT RANGER
ISSUE INFORMATION
PROJECT NO:
CAD DWG FILE:
DESIGNED BY:
MARK DATE
F0REST SUPERVISOR
FOREST ENGINEER
DATE
DATE
DATE
AGRICULTURE
The Pacific Northwest Region
FOREST SERVICE
UNITED STATES
DEPARTMENT
OF
PROJECT TEAM
Protection Consultants, Inc.
1199 S. Main Street #101 Centerville, Utah 84014
801.295.6070 Fax 801.677.0000
NATIONAL FOREST
REGION 6
GTJ
BAJ
GTJ
11/01/16
15072
ALARM SYSTEM UPGRADE
CACHE FIRE SPRINKLER AND
REDMOND AIR CENTER FIRE
11/01/16
9 9
FIRE ALARM KEY NOTES
SIGNAL.
ACTIVATION OF WATER FLOW SWITCH AS A FIRE ALARM
WATER FLOW SWITCH TO NEW FACP. PROGRAM
ADDRESSABLE MONITOR MODULE AND CONNECT
SWITCH (INCLUDING 2 SETS OF CONTACTS). INSTALL
NEW FIRE SPRINKLER RISER WITH WATER FLOW
ADMINISTRATION BUILDING AS REQUIRED.
REVISE FACP PROGRAMMING OF EXISTING FACP IN
ADMINISTRATION BUILDING. ADD MODULES AND
SUPERVISORY AND TROUBLE SIGNALS TO FACP IN
ALARM SYSTEM SHALL RELAY FIRE ALARM,
COMPATIBLE WITH NEW FIRE ALARM SYSTEM. FIRE
FUNCTIONAL (NO SHORTS OR GROUND FAULTS) AND IF
BURIED CONDUIT MAY BE RE-USED IF COMPLETELY
SUPPRESSION PER NFPA 70. EXISTING WIRING IN
BUILDINGS. PROVIDE TRANSIENT VOLTAGE
WIRING IN EXISTING BURIED CONDUIT BETWEEN
ADJACENT ADMINISTRATION BUILDING. INSTALL
CACHE WAREHOUSE TO EXISTING SIMPLEX FACP IN
PROVIDE CIRCUITS TO CONNECT NEW FACP IN FIRE
FACP.
10.4.4. DETECTOR SHALL BE LISTED COMPATIBLE WITH
CONTROL EQUIPMENT IN ACCORDANCE WITH NFPA 72
INSTALL SMOKE DETECTOR ABOVE FIRE ALARM
AS A FIRE ALARM SIGNAL.
PROGRAM ACTIVATION OF FIRE SUPPRESSION SYSTEM
SUPPRESSION SYSTEM CONTROLS TO NEW FACP.
MODULE AND CONNECT ACTIVATION RELAY OF FIRE
TO REMAIN. INSTALL ADDRESSABLE MONITOR
EXISTING FIRE SUPPRESSION SYSTEM IN FUME HOOD
DEMOLISHED (SEE SHEET FP103) MAY BE REUSED.
CONTROLS AND EXISTING FIRE ALARM RELAY TO BE
BUILDING. CONTROL WIRING BETWEEN HVAC
MOUNTED OR SPOT TYPE SMOKE DETECTOR IN
FAN SHUTDOWN UPON ACTUATION OF ANY DUCT
EXCESS OF 2,000 CFM. PROGRAM RELAY TO INITIATE
OF ALL AIR HANDLING SYSTEMS WITH A CAPACITY IN
INSTALL ADDRESSABLE RELAY TO INITIATE SHUTDOWN
LEVEL.
MEZZANINE TO PROVIDE VISIBLE ALARM ON MEZZANINE
INSTALL STROBE ON ROOF DECK ABOVE STORAGE
ABOVE GRADE ON WEATHER-PROOF BACK BOX.
FOR EXTERIOR USE AND SHALL BE MOUNTED AT 10’-0"
AREAS. NOTIFICATION APPLIANCES SHALL BE LISTED
AUDIBLE AND VISIBLE ALARMS FOR EXTERIOR WORK
FIRE ALARM NOTIFICATION APPLIANCES TO PROVIDE
FOR SIGNIFICANT OCCUPANT LOAD. INSTALL EXTERIOR
SEASONAL WORK AREAS AND HAVE THE POTENTIAL
PORTIONS OF BUILDING EXTERIOR ARE USED AS
SPRINKLER RISER.
CONTACTS OF WATER FLOW SWITCH ON FIRE
POWER SUPPLY SWITCHED THROUGH NORMALLY OPEN
WATER FLOW ALARM. CONNECT BELL TO 120 VAC
FIRE DEPARTMENT CONNECTION TO PROVIDE LOCAL
INSTALL 10" ELECTRIC BELL ABOVE FIRE SPRINKLER
FIRE ALARM GENERAL NOTES
1.
2.
D. NFPA 72 2013 EDITION
C. NFPA 70 2015 EDITION
B. INTERNATIONAL FIRE CODE (IFC) - 2015 EDITION
A. INTERNATIONAL BUILDING CODE (IBC) - 2015 EDITION
APPLICABLE CODES AND STANDARDS:
3.
4.
5.
6.
7.
8.
9.
11.
POWER.
PROVIDE A MINIMUM OF 5 MINUTES OF ALARM
STANDBY POWER WITH AN ADIDTIONAL RESERVE TO
72. SIZE BATTERIES TO PROVIDE 24 HOURS OF
BATTERIES) POWER SUPPLY PER NFPA 70 AND NFPA
AND SECONDARY (24VDC USING TWO 12 VDC
INSTALL NEW PRIMARY (120 VAC) POWER SUPPLY
LOCATION OF EXISTING FACP TO BE DEMOLISHED.
PANEL (FACP). SURFACE MOUNT ON WALL AT
NEW SIMPLEX, ADDRESSABLE FIRE ALARM CONTROL
POWER.
PROVIDE A MINIMUM OF 5 MINUTES OF ALARM
STANDBY POWER WITH AN ADIDTIONAL RESERVE TO
72. SIZE BATTERIES TO PROVIDE 24 HOURS OF
BATTERIES) POWER SUPPLY PER NFPA 70 AND NFPA
AND SECONDARY (24VDC USING TWO 12 VDC
INSTALL NEW PRIMARY (120 VAC) POWER SUPPLY
SUPPLIES TO BE DETERMINED BY CONTRACTOR.
REQUIRED NUMBER AND LOCATION OF POWER
REQUIRED POWER CANNOT BE SUPPLIED BY FACP.
NOTIFICATION APPLIANCES IN BUILDING WHERE
AS REQUIRED TO PROVIDE 24 VDC POWER TO
INSTALL NOTIFICATION APPLIANCE POWER SUPPLIES
RELAY MAY BE REUSED.
BETWEEN EXHAUST FAN CONTROLS AND FIRE ALARM
VERIFIED BY CONTRACTOR). CONTROL WIRING
ACTIVATION OF WAREHOUSE EXHAUST FANS (TO BE
DEMOLISHED. FUNCTION OF RELAY IS ASSUMED TO BE
FIRE ALARM RELAY AT THIS LOCATION TO BE
INSTALL ADDRESSABLE RELAY TO REPLACE EXISTING
AFF.
SURFACE MOUNT ON WALL AT APPROXIMATELY 54"
AND ALLOW CONTROL OF FIRE ALARM SYSTEM.
INSTALL ANNUNCIATOR PANEL TO DISPLAY STATUS
MAY BE REUSED.
WIRING BETWEEN SOLENOID AND FIRE ALARM RELAY
DETECTOR OR FLOW SWITCH IN BUILDING. CONTROL
OPERATE SOLENOID UPON ACTUATION OF ANY
NEW ADDRESSABLE RELAY AND PROGRAM RELAY TO
SUPPLY TO BOILER. REPLACE EXISTING RELAY WITH
CONTRACTOR) TO ACTIVATE SOLENOID ON GAS
(LOCATION UNKNOWN - TO BE DETERMINED BY
EXISTING FIRE ALARM SYSTEM INCLUDES RELAY
10.
OF IBC, IFC AND NFPA 72.
ALARM SYSTEM SHALL COMPLY WITH ALL APPLICABLE PROVISIONS
ADMINISTRATION BUILDING. DESIGN AND INSTALLATION OF FIRE
CONNECTION TO EXISTING SIMPLEX FACP IN ADJACENT
SIMPLEX FIRE ALARM SYSTEM IN CACHE WAREHOUSE AND
OF EXISTING FIRE ALARM SYSTEM AND INSTALLATION OF NEW
SCOPE OF WORK: WORK SHALL INCLUDE COMPLETE DEMOLITION
WITH THE NEW FIRE ALARM CONTROL PANEL (FACP).
SYSTEMS. ALL INITIATING DEVICES SHALL BE LISTED COMPATIBLE
BE UL LISTED AND/OR FM APPROVED FOR USE IN FIRE PROTECTION
DEVICES USED FOR THE FIRE ALARM SYSTEM INSTALLATION SHALL
QUALITY ASSURANCE: ALL NEW EQUIPMENT, MATERIAL AND
THE CONSTRUCTION DOCUMENTS REQUIREMENTS OF NFPA 72.
INSTALLING ANY EQUIPMENT. SUBMITTALS SHALL CONFORM TO
JURISDICTION FOR REVIEW/APPROVAL PRIOR TO ORDERING OR
AND SUBMIT SHOP DRAWINGS TO ALL AUTHORITIES HAVING
SUBMITTALS: FIRE ALARM SYSTEM CONTRACTOR SHALL PREPARE
FOR RELAY TO OFF-PREMISE MONITORING STATION.
EXISTING SIMPLEX FACP IN ADJACENT ADMINISTRATION BUILDING
SYSTEM PROVIDES OFF-PREMISE NOTIFICATION OF STATUS TO
REQUIREMENTS FOR PROTECTED PREMISE FIRE ALARM SYSTEMS.
SYSTEM TYPE: FIRE ALARM SYSTEM SHALL MEET THE
EQUIVALENT AS PER NFPA 70 ARTICLE 760.
BE FPL (FIRE POWER LIMITED) WITH 300V INSULATION OR
COMPOUND. ALL WIRING USED IN THE FIRE ALARM SYSTEM SHALL
PARTITIONS SHALL BE FIRE STOPPED WITH A SUITABLE CAULKING
FLEXIBLE CONDUIT. ALL PENETRATIONS THROUGH RATED
GROUNDS. ALL WIRING SHALL BE INSTALLED IN RIGID, EMT OR
SHALL BE NEW. WIRING SHALL BE FREE OF OPENS, SHORTS AND
WIRING/CONDUIT: ALL WIRING (UNLESS OTHERWISE NOTED)
B CIRCUITS.
APPLIANCE CIRCUITS SHALL MEET THE REQUIREMENTS FOR CLASS
MEET THE REQUIREMENTS FOR CLASS A CIRCUITS. NOTIFICATION
WIRING STYLES (PER NFPA 72): INITIATING DEVICE CIRCUITS SHALL
MARKED AND IDENTIFIED AS "FIRE ALARM CIRCUIT".
MECHANICALLY PROTECTED AND SHALL BE PERMANENTLY
PANEL (EXISTING MAY BE REUSED). CIRCUIT SHALL BE
BRANCH CIRCUIT (20 AMP) FROM NEARBY POWER DISTRIBUTION
CONTROL EQUIPEMNT SHALL BE PROVIDED BY A DEDICATED
POWER: PRIMARY POWER SUPPLY TO NEW FIRE ALARM
F. DUCT MOUNTED SMOKE DETECTORS
E. FIRE SUPPRESSION SYSTEM IN FUME HOOD
D. FIRE SPRINKLER WATER FLOW SWITCH
INSTALLATION OF SMOKE DETECTORS
C. HEAT DETECTORS: INSTALL IN AREAS NOT SUITABLE FOR
INDICATED
ALARM CONTROL EQUIPMENT AND THROUGHOUT BUILDING AS
B. SMOKE DETECTORS: INSTALL SMOKE DETECTOR ABOVE FIRE
A. MANUAL PULL STATION
INITIATING DEVICES:
MAINTENANCE PERSONNEL AND REDMOND FIRE DEPARTMENT.
WITNESSED BY PROJECT ENGINEER, US FOREST SERVICE
ACCEPTANCE TESTS REQUIRED BY NFPA 72. TESTING SHALL BE
TESTING: CONTRACTOR SHALL SCHEDULE AND PERFORM ALL
NEW FIRE ALARM SYSTEM HAS BEEN INSTALLED AND TESTED.
DEMOLITION OF EXISTING FIRE ALARM SYSTEM TO OCCUR AFTER
BUILDING THROUGHOUT DURATION OF PROJECT. PHASE
PHASING: FIRE ALARM PROTECTION SHALL BE PROVIDED FOR
12.
ALL DETECTORS THAT MAY BE REQUIRED ARE SHOWN ON PLANS.
THE PHYSICAL CONFIGURATION OF THE EXISTING BUILDING. NOT
MEETING THE REQUIREMENTS OF NFPA 72 AND CONFORMING TO
NUMBER AND LOCATION OF DETECTORS FOR 100% COVERAGE
FIRE ALARM CONTRACTOR IS RESPONSIBLE FOR DETERMINING
1 01/8" = 1’-0" 4’ 8’ 16’
PUMP REPAIR
PUMP REPAIR
W A
R E
H O
U S
E
TOOL MAINTENANCE
MECHANICAL
PAINTING
OVEN REPAIR MEN
WOMEN
OFFICE
OFFICE
OFFICE
OFFICE
F
SD
SD
M
R
R
FP104.DWG
STORAGE
FAPS
FACP
Cache Warehouse Fire Alarm Plan -
FP104
FIRE ALARM PLAN - CACHE WAREHOUSE
FIRE ALARM CONTROL PANEL
SMOKE DETECTOR
FIRE ALARM PULL STATION
FIRE SPRINKLER WATER FLOW SWITCH
MONITOR MODULE
FAPS
FACP FIRE ALARM NOTIFICATION APPLIANCE POWER SUPPLY
F
M
R
SD DUCT MOUNTED SMOKE DETECTOR WITH HOUSING
FIRE ALARM CONTROL RELAY
R
N
N
R
N
N
WALL MOUNT HORN/STROBE ON EXISTING J-BOX
WALL MOUNT HORN/STROBE ON NEW J-BOX
CEILING MOUNT HORN/STROBE ON EXISTING J-BOX
CEILING MOUNT HORN/STROBE ON NEW J-BOX
CEILING OR WALL MOUNT STROBE ON NEW J-BOX
BACK BOX
WALL MOUNT HORN/STROBE ON NEW WEATHER-PROOF
EXTERIOR WATER FLOW BELL
N
30CD
NN
75CD75CD
N
75CD
N75CD
R
75CD
R
75CD
N
110CD
R
115CD
115CD
R
115CD
N
115CD
N
115CD
N
115CD
N
110CD
R
110CD
N
110CD
R
15CD
N
R
110CD
15CD
N
N
15CD
R
30CD
N
30CD
R
15CD
R
15CD
15CD
N
N
15CD
R
30CD
R
75CD
75CD
R
75CD
N
R
75CD
M
75CD
R
R
15CD
BELOW PLATFORM
DETECTORS ABOVE AND
OFFICE CEILING
DETECTOR BELOW
ROOF DECK
DETECTOR ON
ROOF DECK
DETECTOR ON
STORAGE PLATFORM
DETECTOR BELOW
A N
N
OFFICE CEILING
DETECTOR BELOW
R
H
H
H
H
H
H
ANN FIRE ALARM ANNUNCIATOR PANEL
HEAT DETECTOR
Case, Lowe & Hart, Inc. 2484 Washington Blvd.
Suite 510 Ogden, Utah 84401
801.399.5821 Fax 801.399.0728 www.clhae.com
SHEET OF
DRAWN BY:
CHECKED BY:
DESCHUTES
PACIFIC NORTHWEST
DESCRIPTION
DISTRICT RANGER
ISSUE INFORMATION
PROJECT NO:
CAD DWG FILE:
DESIGNED BY:
MARK DATE
F0REST SUPERVISOR
FOREST ENGINEER
DATE
DATE
DATE
AGRICULTURE
The Pacific Northwest Region
FOREST SERVICE
UNITED STATES
DEPARTMENT
OF
PROJECT TEAM
Protection Consultants, Inc.
1199 S. Main Street #101 Centerville, Utah 84014
801.295.6070 Fax 801.677.0000
NATIONAL FOREST
REGION 6
GTJ
BAJ
GTJ
11/01/16
15072
ALARM SYSTEM UPGRADE
CACHE FIRE SPRINKLER AND
REDMOND AIR CENTER FIRE
11/01/16
| G001 - Title Sheet |
| FP101 |
| FP102 |
| FP103 |
| FP104 |