AF Form 66 - Repair HVAC B17.pdf

PDF 156 KB Posted

Attached to
VGLZ 232030 Repair HVAC B17
Solicitation number
W50S8523B0011
Issued by

About this file

This solicitation is for repair work to the HVAC system at Building B17. The contractor will be required to submit shop drawings, product data, samples, warranty documents, operation and maintenance manuals and other closeout documentation. The period of performance is 365 calendar days from notice to proceed. The project value is estimated between $250,000 to $500,000. The solicitation is set aside for small businesses with a NAICS code of 238220 for plumbing, heating and air conditioning contractors. The pre-bid conference will be held on the date specified in clause 52.236-27. Bids are due by the date listed in box 13 and must include an original bid bond. Funding is not currently available but is expected to be in place by 30 September 2023.

View the file

Other files

Show all 15

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

PROJECT NO.

VGLZ 232030

APPROVED DISAPPROVED

Submittal Schedule - AF Form 66 10

2 Transfer and Acceptance of DOD Real Property - DD Form 1354 60

3 Contractor Hazardous Material Identification - SANGB Form 23 10

4 Solid Waste Recycling and Disposal Reporting Form 72 60

Affirmative Procurement Reporting Form 60

DD Form 1354 60

7 Construction Schedule AF 3064 submittals 10

Construction Photos 45

Safety Documentation as stated 10

Schedule of Test and Inspections 21

Permits, Licenses and Certificates 10

Quality Control Plan 10

Warranties 10

14 Starting System -Testing, Adjusting & Balancing Reports 340

15 O & M Data 15 16 Project Record Documents

Close out Documantation 365 17 Instructional Training Program as applicable 365

Product Data

Common Requirements for HVAC Equipment

19 Product Data For DX Units 30 20 Product Data For Boilers 30 21 Product Data For RTU Packaged Units 30 22 Product Data For AHU Coils 30 23 Shop Drawings 30

Spec Section

C

ER

TI

FI

C

AT

IO

N

O F

C O

M

PL

IA

N

C E

AN

D

C

LO

SE

O

U T

SOLICITATION/CONTRACT NO.PROJECT TITLE

Repair HVAC B17

SCHEDULE OF MATERIAL SUBMITTALS

(AF Form 66 Modified)

NO. OF COPIES REQUIRED

TO BE COMPLETED BY PROJECT ENGINEER

O

PE

R

AT

IN

G

IN

ST

R U

C

TI

O N

S

C

AT

AL

O

G D

AT

A

LI

N

E N

U M

BE

R

M

AN

U

FA

C

TU

R

ER

'S W

AR

R

AN

TY

O

TH

ER

M

AT

ER

IA

L o r

D

AT

A

SH

O

P D

R

AW

IN

G

S

SA

M

PL

ES

C O

LO

R

S

EL

EC

TI

O N

M

AN

U

FA

C

TU

R

ER

'S

R

EC

O M

M

EN

D

AT

IO

N

S

REMARKSFINAL

APPROVAL

CONTRACTOR

RESUBMITTAL

RETURN

SUSPENSION

DATE

ITEM OR DESCRIPTION OF ITEM,

CONTRACT REFERENCE, TYPE OF

SUBMITTAL

FOLLOW-UP

SUBMITTAL

REQUIRED

BY XX DAYS

AFTER

NTP

DATE

RECEIVED

IN

CONTRACTING

DATE

TO

CIVIL

ENGINEERING

DATE CONTRACTOR NOTIFIED

APPROVED DISAPPROVED

Spec Section

C

ER

TI

FI

C

AT

IO

N

O F

C O

M

PL

IA

N

C E

AN

D

C

LO

SE

O

U T

SOLICITATION/CONTRACT NO.PROJECT TITLE

Repair HVAC B17

SCHEDULE OF MATERIAL SUBMITTALS

(AF Form 66 Modified)

NO. OF COPIES REQUIRED

TO BE COMPLETED BY PROJECT ENGINEER

O

PE

R

AT

IN

G

IN

ST

R U

C

TI

O N

S

C

AT

AL

O

G D

AT

A

LI

N

E N

U M

BE

R

M

AN

U

FA

C

TU

R

ER

'S W

AR

R

AN

TY

O

TH

ER

M

AT

ER

IA

L o r

D

AT

A

SH

O

P D

R

AW

IN

G

S

SA

M

PL

ES

C O

LO

R

S

EL

EC

TI

O N

M

AN

U

FA

C

TU

R

O M

M

EN

D

AT

IO

N

S

REMARKSFINAL

APPROVAL

CONTRACTOR

RESUBMITTAL

RETURN

SUSPENSION

DATE

ITEM OR DESCRIPTION OF ITEM,

CONTRACT REFERENCE, TYPE OF

SUBMITTAL

FOLLOW-UP

SUBMITTAL

REQUIRED

BY XX DAYS

AFTER

NTP

DATE

RECEIVED

IN

CONTRACTING

DATE

TO

CIVIL

ENGINEERING

DATE CONTRACTOR NOTIFIED

24 O & M Data 30 25 Warranty 30

26 Common Requirements for Pumps

27 Product Data For Pumps 30 28 Product Data For VFDs 30 29 Product Data For Isolation Valves 30 30 Shop Drawings 30 31 O & M Data 30 32 Warranty 30

Boiler Accessories 45 Product Data For Air Seperators 45 Product Data For Exppansion Tanks 45 Product Data For Chem Shot Feeder 45 Shop Drawings 45 O & M Data 45 Warranty 45

33 Sleeves and Sleeve Seal for HVAC Piping 34 Product Data for General Duty Valves 15 35 Escutcheons for HVAC Piping 36 Product Data 45 37 Piping and Guages 38 Product Data for Piping and Gages 45 39 Shop Drawing 45 40 O & M Data 45 41 Warranty 45 42 Piping Valves 45 43 Product Data for General Duty Valves 45 44 Hangers & Supports for HVAC Piping &

Equipment 45 Product Data 45 46 Shop Drawing 45 47 O & M Data 45 48 Warranty 45

Identifcation for HVAC Piping and Equipment

50 Product Data as req'd 51 Sample for ID as req'd 52 Equipment Label Schedule / Scheme as req'd 53 Valve Schedule as req'd 54 Testing, Adjusting, & Balancing for HVAC 55 Qualification Data as req'd

APPROVED DISAPPROVED

Spec Section

C

ER

TI

FI

C

AT

IO

N

O F

C O

M

PL

IA

N

C E

AN

D

C

LO

SE

O

U T

SOLICITATION/CONTRACT NO.PROJECT TITLE

Repair HVAC B17

SCHEDULE OF MATERIAL SUBMITTALS

(AF Form 66 Modified)

NO. OF COPIES REQUIRED

TO BE COMPLETED BY PROJECT ENGINEER

O

PE

R

AT

IN

G

IN

ST

R U

C

TI

O N

S

C

AT

AL

O

G D

AT

A

LI

N

E N

U M

BE

R

M

AN

U

FA

C

TU

R

ER

'S W

AR

R

AN

TY

O

TH

ER

M

AT

ER

IA

L o r

D

AT

A

SH

O

P D

R

AW

IN

G

S

SA

M

PL

ES

C O

LO

R

S

EL

EC

TI

O N

M

AN

U

FA

C

TU

R

O M

M

EN

D

AT

IO

N

S

REMARKSFINAL

APPROVAL

CONTRACTOR

RESUBMITTAL

RETURN

SUSPENSION

DATE

ITEM OR DESCRIPTION OF ITEM,

CONTRACT REFERENCE, TYPE OF

SUBMITTAL

FOLLOW-UP

SUBMITTAL

REQUIRED

BY XX DAYS

AFTER

NTP

DATE

RECEIVED

IN

CONTRACTING

DATE

TO

CIVIL

ENGINEERING

DATE CONTRACTOR NOTIFIED

56 Contract Document Examination Report as req'd 57 Certified TAB Reports as req'd 59 HVAC Piping Insulation 60 Product Data on Insulation as req'd 61 Samples of Insulation as req'd 62 HVAC Controls 63 Product Data on DDC System & Controls 45 64 Shop Drawing 45 65 Data Comm. Protocol Certificates 45 66 Control Valves 45 67 Product Data 45 68 Shop Drawing 45 69 O & M Data 45 70 Warranty 45 71 Sequence of Operation for HVAC DDC 72 Control Sequences 45 73 Refrigerant Piping 45 74 Product Data 45 75 Piping Schedule 45 76 Piping Specialties 45 77 O & M Data 45 78 Metal Ducts 79 Product Data on the following material: 45 80 Sealants and Gaskets 45 81 Seismic Restraint Devices 45 82 Shop Drawings 45 83 Air Duct Accessories 84 Product Data 85 Shop Drawings for Duct Accessories 86 O & M Data 88 Gas-Fired Boilers 89 Product Data 90 Shop Drawing 91 Warranty 92 O & M Data

93 Packaged Compressor and Condensing Units

94 Product Data as req'd 95 Shop Drawing as req'd 96 Warranty as req'd 97 O & M Data as req'd 98 Roof Top Pkg Units

APPROVED DISAPPROVED

Spec Section

C

ER

TI

FI

C

AT

IO

N

O F

C O

M

PL

IA

N

C E

AN

D

C

LO

SE

O

U T

SOLICITATION/CONTRACT NO.PROJECT TITLE

Repair HVAC B17

SCHEDULE OF MATERIAL SUBMITTALS

(AF Form 66 Modified)

NO. OF COPIES REQUIRED

TO BE COMPLETED BY PROJECT ENGINEER

O

PE

R

AT

IN

G

IN

ST

R U

C

TI

O N

S

C

AT

AL

O

G D

AT

A

LI

N

E N

U M

BE

R

M

AN

U

FA

C

TU

R

ER

'S W

AR

R

AN

TY

O

TH

ER

M

AT

ER

IA

L o r

D

AT

A

SH

O

P D

R

AW

IN

G

S

SA

M

PL

ES

C O

LO

R

S

EL

EC

TI

O N

M

AN

U

FA

C

TU

R

O M

M

EN

D

AT

IO

N

S

REMARKSFINAL

APPROVAL

CONTRACTOR

RESUBMITTAL

RETURN

SUSPENSION

DATE

ITEM OR DESCRIPTION OF ITEM,

CONTRACT REFERENCE, TYPE OF

SUBMITTAL

FOLLOW-UP

SUBMITTAL

REQUIRED

BY XX DAYS

AFTER

NTP

DATE

RECEIVED

IN

CONTRACTING

DATE

TO

CIVIL

ENGINEERING

DATE CONTRACTOR NOTIFIED

99 Product Data as req'd 100 Shop Drawing as req'd 101 Warranty as req'd 102 O & M Data as req'd 103 Low-Voltage Electrical Power Conductors

& Cables as req'd 104 Product Data for Each Type of Cable as req'd 105 Grounding & Bonding for Electrical

Systems 106 O & M Data as req'd 107 Raceway & Boxes for Electrical Systems 108 Product Data on the following Material: as req'd 109 Metal Conduit & Tubing as req'd 110 Metal Wireways as req'd 111 Surface Raceways as req'd 112 Boxes, Enclosures, Cabinets as req'd 113 Panelboards 114 Product Data as req'd 115 Shop Drawings as req'd 116 O & M Data as req'd 117 Warranty as req'd 118 Enclosed Switches 119 Product Data as req'd 120 Shop Drawings as req'd 121 O & M Data as req'd 122 Enclosed Controllers 123 Product Data as req'd 124 Shop Drawings as req'd 125 O & M Data as req'd 126 Roof Patching 127 Product Data as req'd 128 Shop Drawings as req'd 129 O & M Data as req'd

APPROVED DISAPPROVED

Spec Section

C

ER

TI

FI

C

AT

IO

N

O F

C O

M

PL

IA

N

C E

AN

D

C

LO

SE

O

U T

SOLICITATION/CONTRACT NO.PROJECT TITLE

Repair HVAC B17

SCHEDULE OF MATERIAL SUBMITTALS

(AF Form 66 Modified)

NO. OF COPIES REQUIRED

TO BE COMPLETED BY PROJECT ENGINEER

O

PE

R

AT

IN

G

IN

ST

R U

C

TI

O N

S

C

AT

AL

O

G D

AT

A

LI

N

E N

U M

BE

R

M

AN

U

FA

C

TU

R

ER

'S W

AR

R

AN

TY

O

TH

ER

M

AT

ER

IA

L o r

D

AT

A

SH

O

P D

R

AW

IN

G

S

SA

M

PL

ES

C O

LO

R

S

EL

EC

TI

O N

M

AN

U

FA

C

TU

R

O M

M

EN

D

AT

IO

N

S

REMARKSFINAL

APPROVAL

CONTRACTOR

RESUBMITTAL

RETURN

SUSPENSION

DATE

ITEM OR DESCRIPTION OF ITEM,

CONTRACT REFERENCE, TYPE OF

SUBMITTAL

FOLLOW-UP

SUBMITTAL

REQUIRED

BY XX DAYS

AFTER

NTP

DATE

RECEIVED

IN

CONTRACTING

DATE

TO

CIVIL

ENGINEERING

DATE CONTRACTOR NOTIFIED

File details come from the government source that posted it. Updated .