Addendum_No._2_City_Standard_Detail_W-5.pdf
PDF 932 KB Posted
- Attached to
- Ironwood Water Main Replacement Project
- Solicitation number
- 25-016EJ
- Issued by
- Manatee County, Florida
About this file
This is an addendum document issued by the City of Bradenton, Florida, Department of Engineering and Public Works and Utilities for the Ironwood Water Main Replacement Project. Addendum No. 2 establishes technical specifications for PVC pipe thrust restraint requirements at fittings, valves, and joints throughout the water distribution system. The addendum specifies that EBBA Iron Megalug restrainers must be used at fittings and valves, while EBBA Iron Series 1500 restrainers are required between pipe joints, with all calculations based on 30 inches of cover depth. Critical components requiring complete restraint include bends at inlet and outlet locations, tees, offsets at inlet and outlet locations, caps, plugs, and entire hydrant runouts in all applications.
This addendum clarifies mandatory restraint specifications to ensure structural integrity and prevent pipe movement in the approximately 5,180 linear feet of water main construction involving various pipe sizes and configurations. By establishing these standardized restraint requirements upfront, the City ensures that all bidders understand the technical requirements and can provide accurate pricing for the specialized materials and installation methods necessary to meet the water distribution system's performance standards.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
W-5
ADDENDUM NO. 2
AutoCAD SHX Text
P.V.C. PIPE RESTRAINT
AutoCAD SHX Text
THRUST RESTRAINING
AutoCAD SHX Text
CHART
AutoCAD SHX Text 2/07
AutoCAD SHX Text
CITY OF BRADENTON, FLORIDA
AutoCAD SHX Text
DATE
AutoCAD SHX Text
SHEET NO.
AutoCAD SHX Text
REV.
AutoCAD SHX Text
DATE
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
BY
AutoCAD SHX Text
PUBLIC WORKS AND UTILITIES
AutoCAD SHX Text
DEPARTMENT OF ENGINEERING
AutoCAD SHX Text
WATER DISTRIBUTION
AutoCAD SHX Text NOTE: : THRUST RESTRAINT AT FITTINGS AND VALVES SHALL BE EBBA IRON MEGALUG RESTTAINERS. THRUST RESTRAINT BETWEEN PIPE JOINTS SHALL BE EBBA IRON SERIES 1500 RESTRAINERS. FIGURES BASED ON 30" OF COVER DEPTH.
AutoCAD SHX Text THE FOLLOWING JOINTS MUST BE RESTRAINED IN ALL APPLICATIONS: 1. BEND - INLET AND OUTLET BEND - INLET AND OUTLET 2. TEES TEES 3. OFFSETS - INLET AND OUTLET OFFSETS - INLET AND OUTLET 4. CAPS CAPS 5. PLUGS PLUGS 6. ENTIRE HYDRANT RUNOUTS SHALL BE RESTRAINEDENTIRE HYDRANT RUNOUTS SHALL BE RESTRAINED