Addendum_No._2_City_Standard_Detail_W-5.pdf

PDF 932 KB Posted

Attached to
Ironwood Water Main Replacement Project
Solicitation number
25-016EJ
Issued by
Manatee County, Florida

About this file

This is an addendum document issued by the City of Bradenton, Florida, Department of Engineering and Public Works and Utilities for the Ironwood Water Main Replacement Project. Addendum No. 2 establishes technical specifications for PVC pipe thrust restraint requirements at fittings, valves, and joints throughout the water distribution system. The addendum specifies that EBBA Iron Megalug restrainers must be used at fittings and valves, while EBBA Iron Series 1500 restrainers are required between pipe joints, with all calculations based on 30 inches of cover depth. Critical components requiring complete restraint include bends at inlet and outlet locations, tees, offsets at inlet and outlet locations, caps, plugs, and entire hydrant runouts in all applications.

This addendum clarifies mandatory restraint specifications to ensure structural integrity and prevent pipe movement in the approximately 5,180 linear feet of water main construction involving various pipe sizes and configurations. By establishing these standardized restraint requirements upfront, the City ensures that all bidders understand the technical requirements and can provide accurate pricing for the specialized materials and installation methods necessary to meet the water distribution system's performance standards.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

W-5

ADDENDUM NO. 2

AutoCAD SHX Text

P.V.C. PIPE RESTRAINT

AutoCAD SHX Text

THRUST RESTRAINING

AutoCAD SHX Text

CHART

AutoCAD SHX Text 2/07

AutoCAD SHX Text

CITY OF BRADENTON, FLORIDA

AutoCAD SHX Text

DATE

AutoCAD SHX Text

SHEET NO.

AutoCAD SHX Text

REV.

AutoCAD SHX Text

DATE

AutoCAD SHX Text

DESCRIPTION

AutoCAD SHX Text

BY

AutoCAD SHX Text

PUBLIC WORKS AND UTILITIES

AutoCAD SHX Text

DEPARTMENT OF ENGINEERING

AutoCAD SHX Text

WATER DISTRIBUTION

AutoCAD SHX Text NOTE: : THRUST RESTRAINT AT FITTINGS AND VALVES SHALL BE EBBA IRON MEGALUG RESTTAINERS. THRUST RESTRAINT BETWEEN PIPE JOINTS SHALL BE EBBA IRON SERIES 1500 RESTRAINERS. FIGURES BASED ON 30" OF COVER DEPTH.

AutoCAD SHX Text THE FOLLOWING JOINTS MUST BE RESTRAINED IN ALL APPLICATIONS: 1. BEND - INLET AND OUTLET BEND - INLET AND OUTLET 2. TEES TEES 3. OFFSETS - INLET AND OUTLET OFFSETS - INLET AND OUTLET 4. CAPS CAPS 5. PLUGS PLUGS 6. ENTIRE HYDRANT RUNOUTS SHALL BE RESTRAINEDENTIRE HYDRANT RUNOUTS SHALL BE RESTRAINED

File details come from the government source that posted it. Updated .