Addendum 3.pdf
PDF 4 MB Posted
- Solicitation number
- RFB 785 2600000648 4
- Issued by
- Kentucky
About this file
This is Addendum 3 to RFB-04-27 for the Kentucky Department of Juvenile Justice (DJJ) Fire Alarm Replacement Campus Wide project. The addendum provides clarifications and modifications to the original request for bids regarding the installation of a campus-wide fire alarm system at the Kentucky Children's Home (KCH) facility. The document addresses specific technical questions and requirements submitted by potential bidders, including clarifications on existing fire alarm system components, equipment specifications, installation procedures, and coordination with facility operations. Key modifications include adjustments to scope items, clarification of responsibilities between the contractor and DJJ, and additional technical specifications for the fire alarm replacement project. The addendum ensures that all bidders have consistent and accurate information regarding project requirements prior to submitting their proposals.
The addendum emphasizes the importance of bidder compliance with all specifications outlined in the original RFB and previous addenda. It provides technical guidance on system compatibility, testing requirements, and documentation standards that must be met throughout the project. The document clarifies the evaluation criteria and ensures that bids are evaluated fairly based on complete and accurate project specifications. All bidders must acknowledge receipt of Addendum 3 in their bid submissions to be considered responsive to the solicitation.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Final_RFB_785_2600000648_2_SO_FORM.PDF | ||
| Final_RFB_785_2600000648_3_SO_FORM.PDF | ||
| Final_RFB_785_2600000648_4_SO_FORM.PDF | ||
| Final_RFB_785_2600000648_1_SO_FORM.PDF | ||
| Addendum 2.pdf | ||
| Addendum 1.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
COMMONWEALTH OF KENTUCKY
DEPARTMENT FOR FACILITIES AND SUPPORT SERVICES
DIVISION OF ENGINEERING AND CONTRACT ADMINISTRATION
INVITATION TO BID NO: RFB-04-27
FOR: Fire Alarm Replacement Campus Wide Kentucky Children's Home Department of Juvenile Justice Lyndon, Kentucky
DATE: July 10, 2026
RFB-785-2600000648
ADDENDUM NO. Three (3)
BIDDER SHALL CONFORM TO THE FOLLOWING CHANGES AS SAME SHALL BECOME BINDING
UPON THE CONTRACT TO BE ISSUED IN RESPONSE TO THIS INVITATION TO BID.
Item 1: Refer to attached addendum for all additions, deletions, and/or changes to specifications and/or drawings.
END OF ADDENDUM
Invitation to Bid No. RFB-04-27 For: Fire Alarm Replacement Campus Wide Kentucky Children's Home Department of Juvenile Justice Lyndon, Kentucky
Janis Wilhoite, Statewide Procurement Analyst II Division of Engineering and Contract Administration
KHC Fire Alarm Replacement Campus Wide Addendum #2 July 10, 2026
Addendum Items (Questions and Responses):
1. Question: Can existing cabling be re-used for the new system?
Response: No, all cabling shall be new.
2. Question: Will a planned temporary fire alarm impairment for up to a set number of calendar days (~5) be permitted with prior notice and an approved fire watch, or is maintaining the existing system until the new system is online a hard requirement? The latter will greatly increase the effort and cost.
Response: No, all buildings with the exception of the Chapel will remain occupied.
3. Question: Is Fire-Lite and acceptable fire alarm manufacturer?
Response: No, please use the listed manufacturers in the specifications and addendum.
4. Question: On the contract documents under Division 28 Section 283100 11.8 “All electrical work is to be constructed and installed in accordance with plans and specifications which have been approved in their entirety and/or reflect any changes requested by the state fire marshal, as applicable or required. Electrical work shall not commence until such plans are in the hands of the electrical contractor. This seems to say as built drawings require an approval by the state fire marshal. Is that correct? And if so what time frame?
Response: An as built set of drawings reflecting any changes made during construction as well as any changes made from the permitting drawings are to be provided upon completion of construction.
5. Question: On sheet E301, PIV is not shown on plans. It appears to be locked and monitored electronically. Can you confirm if it needs to be monitored electronically and if so who is responsible for replacing the PIV Switch if it is non-functional as it appears that the box is currently damaged?
Response: The contractor is responsible for providing new connections to all building
PIV devices as well as monitoring these. If the existing PIV switch is damaged it is not the responsibility of the contractor to replace this.
6. Question: Will after work hours be permitted upon request?
Response: No, Work hours are from 8AM to 4PM. No weekends or state holidays or overtime.
7. Question: Is a fire watch required only for buildings that are occupied, or is it also required for unoccupied buildings? Additionally, who will be responsible for providing and managing the fire watch—the Owner or the Contractor?
Response: Fire watch is required for all buildings. The contractor is responsible for providing the fire watch per NFPA, State HBC and the Fire Marshal’s Office requirements.
8. Question: What are the permitted working hours for each building? Could you please identify which buildings are currently occupied and which are unoccupied?
Additionally, is after-hours or weekend work allowed for this project, and if so, are there any specific restrictions or timeframes that we should be aware of Response: Work hours are from 8AM to 4PM with no weekends or state holidays or overtime. All buildings are occupied with the exception of the Chapel.
9. Question: Who is responsible for the Elevator permit and re-inspection fees? Is there a specific elevator contractor required or under contract for the facility?
Response: The contractor shall include the elevator recertification price in their bid. DC elevator has serviced the Everett and Johnson Breckenridge buildings.
10. Question: First floor of the Chapel there is an existing beam smoke detector, and the drawings only show 4 existing smoke detectors to demo however there are not 4 existing smoke detectors in the chapel. Can we reuse or replace the existing beam smoke detector in lieu of installing 4 new detectors at the top of the high ceiling?
Response: It is acceptable to replace the existing beam detectors provided all NFPA and code requirements are met.
Addendum Items:
1. General:
a. The electrical set of the current ongoing renovation for the DJJ Lyndon
Building has been included for reference only as requested.
2. Rice Building Drawings:
a. Drawings E500D, E500F, E501D, E501F, E502D and E502F have been updated to include the correct floor plan.
3. General:
a. For clarification, the contractor shall include all new conduit/raceway and wiring for each new/replaced device in their bid.
RTA DATE
DECA LOG #
A&E FILE NO.
MLRCHECKED BY
DRAWN BY
DRAWING DATE
DRAWING INFORMATION
FRANKFORT, KENTUCKY
DIVISION OF ENGINEERING
DEPARTMENT FOR FACILITIES MANAGEMENT
FINANCE AND ADMINISTRATION CABINET
COMMONWEALTH OF KENTUCKY
DRAWING NO.
ACCOUNT NO.
PHASE
LEA
VDLF25
DECA REVIEWED
FOR INTENT ONLY
10411 Meeting Street
Prospect, Kentucky 40059 502 326.3085 f 502 326.2691 www.cmtaegrs.com
RTA
05/04/2026
07/10/26
KCH Fire Alarm Replacement Campus Wide, DJJ Lyndon
523-CAW7-KC12-00
AutoCAD SHX Text
STORAGE
AutoCAD SHX Text
AutoCAD SHX Text
COMMUNICATION
AutoCAD SHX Text
AutoCAD SHX Text
STORAGE
AutoCAD SHX Text
AutoCAD SHX Text
STORAGE
AutoCAD SHX Text
AutoCAD SHX Text
MECH.
AutoCAD SHX Text
AutoCAD SHX Text
STORAGE
AutoCAD SHX Text
AutoCAD SHX Text
STORAGE
AutoCAD SHX Text
AutoCAD SHX Text
MECH. ROOM
AutoCAD SHX Text
AutoCAD SHX Text
BREAK ROOM
AutoCAD SHX Text
AutoCAD SHX Text
DINING ROOM
AutoCAD SHX Text
AutoCAD SHX Text
RESTROOM
AutoCAD SHX Text
AutoCAD SHX Text
STAIRWAY
AutoCAD SHX Text
AutoCAD SHX Text
ELEV. LOBBY
AutoCAD SHX Text
AutoCAD SHX Text
ELEV. EQUIP. ROOM
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
GENERAL DEMOLITION NOTES :
AutoCAD SHX Text A. THICK DOTTED LINES INDICATE ITEMS FOR REMOVAL(U.O.N.) AND THIN SOLID THICK DOTTED LINES INDICATE ITEMS FOR REMOVAL(U.O.N.) AND THIN SOLID LINES INDICATE EXISTING ITEMS TO REMAIN. B. THE CONTRACTOR SHALL MAINTAIN THE CONTINUITY OF EXISTING CIRCUITS THAT THE CONTRACTOR SHALL MAINTAIN THE CONTINUITY OF EXISTING CIRCUITS THAT CONTAIN DEVICES OR EQUIPMENT THAT ARE TO REMAIN. WHEN DEMOLITION OF AN ELECTRICAL DEVICE (OR CIRCUIT) IS INDICATED ON THE DRAWINGS: THE CONTRACTOR SHALL ENSURE THAT OTHER DEVICES OR EQUIPMENT "UPSTREAM" OR "DOWNSTREAM"ON THE CIRCUITS SHALL REMAIN IN "PRE-DEMOLITION" WORKING ORDER. "LEFT-OVER" CIRCUIT BREAKERS SHALL REMAIN, BE SWITCHED TO OFF POSITION, AND BE LABELED AS SPARES IN THEIR PANELS. PROVIDE NEW TYPE WRITTEN DIRECTORIES FOR ALL PANELS AFFECTED. C. LOCATIONS OF DEVICES, CONNECTIONS, ETC., INDICATED ON THIS DRAWING WERE LOCATIONS OF DEVICES, CONNECTIONS, ETC., INDICATED ON THIS DRAWING WERE TAKEN FROM VARIOUS SOURCES. THEY ARE DIAGRAMMATIC ONLY AND ARE SUBJECT TO VARIATION FROM EXISTING CONDITIONS. CERTAIN EXISTING ELEMENTS MAY NOT BE INDICATED AT ALL. THE CONTRACTOR PROPOSING TO DO ANY PART OF THE WORK INDICATED HEREON SHALL VISIT THIS SITE AND DETERMINE TO HIS SATISFACTION THAT THEY MAY COMPLETE ALL WORK REQUIRED FOR THE BID WHICH HE PROPOSES. D. COORDINATE DISPOSAL OF ALL FIXTURES, DEVICES, ETC. (INDICATED FOR COORDINATE DISPOSAL OF ALL FIXTURES, DEVICES, ETC. (INDICATED FOR DEMOLITION) WITH OWNER. E. CONTRACTOR SHALL PATCH AND REPAIR ALL EXISTING WALLS AS REQUIRED CONTRACTOR SHALL PATCH AND REPAIR ALL EXISTING WALLS AS REQUIRED WHERE NEW FLUSH MOUNTED DEVICES ARE BEING REMOVED. F. CONTRACTOR SHALL PATCH AND REPAIR DUCTWORK AS REQUIRED WHEREVER CONTRACTOR SHALL PATCH AND REPAIR DUCTWORK AS REQUIRED WHEREVER DUCT SMOKE DETECTORS ARE BEING REMOVED OR INSTALLED. G. SOME EXISTING SIMPLEX PULL STATIONS AND NOTIFICATION DEVICES SERVE THE SOME EXISTING SIMPLEX PULL STATIONS AND NOTIFICATION DEVICES SERVE THE DURESS ALARM SYSTEM AND ARE NOT A PART OF THE EXISTING FIRE ALARM SYSTEM. CONTRACTOR SHALL VERIFY THAT ALL DEVICES TO BE REMOVED ARE A PART OF THE FIRE ALARM SYSTEM. H. CONTRACTOR SHALL STORE, PROTECT AND TURN OVER ALL REMOVED SMOKE CONTRACTOR SHALL STORE, PROTECT AND TURN OVER ALL REMOVED SMOKE DETECTORS, NOTIFICATION DEVICES AND FACP COMPONENTS TO OWNER.
AutoCAD SHX Text
TAGGED NOTES :
AutoCAD SHX Text
1. NOT USED.NOT USED.
AutoCAD SHX Text
DATE
AutoCAD SHX Text
DESCRIPTION OF REVISIONS
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
REVISION HISTORY OF THIS DRAWING
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
DATE
AutoCAD SHX Text
DESCRIPTION OF REVISIONS
AutoCAD SHX Text
RICE - BASEMENT - DEMOLITION
AutoCAD SHX Text
SCALE: 3/16'' = 1'-0"
AutoCAD SHX Text E500D
AutoCAD SHX Text
AutoCAD SHX Text E500D
AutoCAD SHX Text
RICE - BASEMENT - DEMOLITION
A&E FILE NO.
MLRCHECKED BY
DRAWN BY
DRAWING DATE
DRAWING INFORMATION
FRANKFORT, KENTUCKY
DIVISION OF ENGINEERING
DEPARTMENT FOR FACILITIES MANAGEMENT
FINANCE AND ADMINISTRATION CABINET
COMMONWEALTH OF KENTUCKY
DRAWING NO.
ACCOUNT NO.
PHASE
LEA
VDLF25
DECA REVIEWED
FOR INTENT ONLY
10411 Meeting Street
Prospect, Kentucky 40059 502 326.3085 f 502 326.2691 www.cmtaegrs.com
RTA
05/04/2026
07/10/26
KCH Fire Alarm Replacement Campus Wide, DJJ Lyndon
523-CAW7-KC12-00
AutoCAD SHX Text
STORAGE
AutoCAD SHX Text
AutoCAD SHX Text
COMMUNICATION
AutoCAD SHX Text
AutoCAD SHX Text
STORAGE
AutoCAD SHX Text
AutoCAD SHX Text
STORAGE
AutoCAD SHX Text
AutoCAD SHX Text
MECH.
AutoCAD SHX Text
AutoCAD SHX Text
STORAGE
AutoCAD SHX Text
AutoCAD SHX Text
STORAGE
AutoCAD SHX Text
AutoCAD SHX Text
MECH. ROOM
AutoCAD SHX Text
AutoCAD SHX Text
BREAK ROOM
AutoCAD SHX Text
AutoCAD SHX Text
DINING ROOM
AutoCAD SHX Text
AutoCAD SHX Text
RESTROOM
AutoCAD SHX Text
AutoCAD SHX Text
STAIRWAY
AutoCAD SHX Text
AutoCAD SHX Text
ELEV. LOBBY
AutoCAD SHX Text
AutoCAD SHX Text
ELEV. EQUIP. ROOM
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text F
AutoCAD SHX Text F
AutoCAD SHX Text F
AutoCAD SHX Text F
AutoCAD SHX Text
EL
AutoCAD SHX Text
EL
AutoCAD SHX Text
EL
AutoCAD SHX Text F
AutoCAD SHX Text F
AutoCAD SHX Text
CM
AutoCAD SHX Text
CM
AutoCAD SHX Text
CM
AutoCAD SHX Text
CM
AutoCAD SHX Text
CM
AutoCAD SHX Text
CM
AutoCAD SHX Text
CM
AutoCAD SHX Text
CM
AutoCAD SHX Text
CM
AutoCAD SHX Text
CM
AutoCAD SHX Text
CM
AutoCAD SHX Text
CM
AutoCAD SHX Text
CM
AutoCAD SHX Text
CM
AutoCAD SHX Text
CM
AutoCAD SHX Text
CM
AutoCAD SHX Text
CM
AutoCAD SHX Text
CM
AutoCAD SHX Text
CM
AutoCAD SHX Text
CM
AutoCAD SHX Text
CM
AutoCAD SHX Text
CM
AutoCAD SHX Text
CM
AutoCAD SHX Text
CM
AutoCAD SHX Text
GENERAL POWER/SYSTEMS NOTES :
AutoCAD SHX Text A. REFER TO THE ARCHITECT'S REFLECTED CEILING PLANS, ELEVATIONS, AND REFER TO THE ARCHITECT'S REFLECTED CEILING PLANS, ELEVATIONS, AND CASEWORK DETAILS FOR EXACT LOCATIONS OF ALL WALL AND CEILING MOUNTED ELECTRICAL DEVICES. B. CONTRACTOR SHALL FOLLOW BRANCH CIRCUITING LAY-OUT, AS INDICATED ON CONTRACTOR SHALL FOLLOW BRANCH CIRCUITING LAY-OUT, AS INDICATED ON THE FLOOR PLANS, WITH A MAXIMUM OF THREE (3) BRANCH CIRCUITS PER HOMERUN. EACH BRANCH CIRCUIT SHALL BE PROVIDED WITH A DEDICATED NEUTRAL CONDUCTOR. DEDICATED NEUTRAL CONDUCTORS SHALL BE CONSIDERED CURRENT CARRYING. IF ADDITIONAL CONDUCTORS ARE RAN IN THE SAME CONDUIT WITH THOSE INDICATED, CONTRACTOR SHALL DERATE ALL CURRENT CARRYING CONDUCTORS PER NEC 310.15(B)(3), AND UPSIZE CONDUIT AS REQUIRED PER NEC 300.17 AND ANNEX C. MULTIWIRE BRANCH CIRCUITS AS DEFINED IN NEC 100/210.4(CIRCUITS SHARING A COMMON NEUTRAL CONDUCTOR) SHALL NOT BE PERMITTED. C. IDENTIFY THE PANEL AND CIRCUIT NUMBER FOR ALL RECEPTACLES, SWITCHES, IDENTIFY THE PANEL AND CIRCUIT NUMBER FOR ALL RECEPTACLES, SWITCHES, ETC. IN AREA OF CONSTRUCTION. PROVIDE CLEAR ADHESIVE LABELS WITH BLACK LETTERING. IN HEALTHCARE FACILITIES, ENGRAVE EMERGENCY DEVICE COVERPLATES IN PATIENT CARE AREAS. MARK INSIDES OF ALL DEVICE BOXES WITH PANEL AND CIRCUIT NUMBERS. D. RECEPTACLES THAT ARE CONTROLLED BY AN AUTOMATIC MEANS SUCH AS RECEPTACLES THAT ARE CONTROLLED BY AN AUTOMATIC MEANS SUCH AS OCCUPANCY SENSOR OR ENERGY MANAGEMENT SYSTEM SHALL BE MARKED IN ACCORDANCE WITH NEC 406.3(E). E. LOCATIONS OF ELECTRICAL CONNECTIONS AND LOCAL DISCONNECTS SHALL BE LOCATIONS OF ELECTRICAL CONNECTIONS AND LOCAL DISCONNECTS SHALL BE COORDINATED WITH MECHANICAL AND PLUMBING CONTRACTORS TO ENSURE ACCESS AND WORKING CLEARANCE IS MAINTAINED PER NEC. NOTIFY OTHER TRADES OF REQUIRED CLEARANCE AREAS TO AVOID ROUTING OF OTHER SYSTEMS IN THESE AREAS. DO NOT INSTALL ELECTRICAL EQUIPMENT OVER EQUIPMENT NAMEPLATES OR ACCESS PANELS OR THROUGH ACCESS/MAINTENANCE CLEARANCES OF EQUIPMENT BY OTHER TRADES. F. REFER TO "SYSTEM INSTALLATION MATRIX" (ON SYSTEMS LEGEND SHEET) AND REFER TO "SYSTEM INSTALLATION MATRIX" (ON SYSTEMS LEGEND SHEET) AND SPECIFICATIONS FOR CONTRACTOR REQUIREMENTS OF EACH SYSTEM. G. THE CONTRACTOR SHALL ROUTE ALL "SYSTEM CONDUIT STUB-UPS" TO THE THE CONTRACTOR SHALL ROUTE ALL "SYSTEM CONDUIT STUB-UPS" TO THE NEAREST CORRIDOR CABLING PATH (SEE "STUB-UP" DETAILS). REFER TO CABLING PATH INSTALLATION DETAIL FOR ADDITIONAL REQUIREMENTS. H. CONTRACTOR SHALL PAINT ALL SYSTEMS CONDUIT STUB-UPS LIGHT BLUE FOR CONTRACTOR SHALL PAINT ALL SYSTEMS CONDUIT STUB-UPS LIGHT BLUE FOR SYSTEMS CABLING INTO THE CORRIDOR CABLING PATH. PROVIDE PULL STRINGS IN ALL NEW CONDUIT RUNS FOR SYSTEM CABLING INSTALLATION.
AutoCAD SHX Text
TAGGED NOTES :
AutoCAD SHX Text
1. NOT USED.NOT USED.
AutoCAD SHX Text
DATE
AutoCAD SHX Text
DESCRIPTION OF REVISIONS
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
REVISION HISTORY OF THIS DRAWING
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
DATE
AutoCAD SHX Text
DESCRIPTION OF REVISIONS
AutoCAD SHX Text
RICE - BASEMENT - NEW WORK
AutoCAD SHX Text
SCALE: 3/16'' = 1'-0"
AutoCAD SHX Text E500F
AutoCAD SHX Text
AutoCAD SHX Text E500F
RICE - BASEMENT - NEW WORK
A&E FILE NO.
MLRCHECKED BY
DRAWN BY
DRAWING DATE
DRAWING INFORMATION
FRANKFORT, KENTUCKY
DIVISION OF ENGINEERING
DEPARTMENT FOR FACILITIES MANAGEMENT
FINANCE AND ADMINISTRATION CABINET
COMMONWEALTH OF KENTUCKY
DRAWING NO.
ACCOUNT NO.
PHASE
LEA
VDLF25
DECA REVIEWED
FOR INTENT ONLY
10411 Meeting Street
Prospect, Kentucky 40059 502 326.3085 f 502 326.2691 www.cmtaegrs.com
RTA
05/04/2026
07/10/26
KCH Fire Alarm Replacement Campus Wide, DJJ Lyndon
523-CAW7-KC12-00
AutoCAD SHX Text
GENERAL DEMOLITION NOTES :
AutoCAD SHX Text A. THICK DOTTED LINES INDICATE ITEMS FOR REMOVAL(U.O.N.) AND THIN SOLID THICK DOTTED LINES INDICATE ITEMS FOR REMOVAL(U.O.N.) AND THIN SOLID LINES INDICATE EXISTING ITEMS TO REMAIN. B. THE CONTRACTOR SHALL MAINTAIN THE CONTINUITY OF EXISTING CIRCUITS THAT THE CONTRACTOR SHALL MAINTAIN THE CONTINUITY OF EXISTING CIRCUITS THAT CONTAIN DEVICES OR EQUIPMENT THAT ARE TO REMAIN. WHEN DEMOLITION OF AN ELECTRICAL DEVICE (OR CIRCUIT) IS INDICATED ON THE DRAWINGS: THE CONTRACTOR SHALL ENSURE THAT OTHER DEVICES OR EQUIPMENT "UPSTREAM" OR "DOWNSTREAM"ON THE CIRCUITS SHALL REMAIN IN "PRE-DEMOLITION" WORKING ORDER. "LEFT-OVER" CIRCUIT BREAKERS SHALL REMAIN, BE SWITCHED TO OFF POSITION, AND BE LABELED AS SPARES IN THEIR PANELS. PROVIDE NEW TYPE WRITTEN DIRECTORIES FOR ALL PANELS AFFECTED. C. LOCATIONS OF DEVICES, CONNECTIONS, ETC., INDICATED ON THIS DRAWING WERE LOCATIONS OF DEVICES, CONNECTIONS, ETC., INDICATED ON THIS DRAWING WERE TAKEN FROM VARIOUS SOURCES. THEY ARE DIAGRAMMATIC ONLY AND ARE SUBJECT TO VARIATION FROM EXISTING CONDITIONS. CERTAIN EXISTING ELEMENTS MAY NOT BE INDICATED AT ALL. THE CONTRACTOR PROPOSING TO DO ANY PART OF THE WORK INDICATED HEREON SHALL VISIT THIS SITE AND DETERMINE TO HIS SATISFACTION THAT THEY MAY COMPLETE ALL WORK REQUIRED FOR THE BID WHICH HE PROPOSES. D. COORDINATE DISPOSAL OF ALL FIXTURES, DEVICES, ETC. (INDICATED FOR COORDINATE DISPOSAL OF ALL FIXTURES, DEVICES, ETC. (INDICATED FOR DEMOLITION) WITH OWNER. E. CONTRACTOR SHALL PATCH AND REPAIR ALL EXISTING WALLS AS REQUIRED CONTRACTOR SHALL PATCH AND REPAIR ALL EXISTING WALLS AS REQUIRED WHERE NEW FLUSH MOUNTED DEVICES ARE BEING REMOVED. F. CONTRACTOR SHALL PATCH AND REPAIR DUCTWORK AS REQUIRED WHEREVER CONTRACTOR SHALL PATCH AND REPAIR DUCTWORK AS REQUIRED WHEREVER DUCT SMOKE DETECTORS ARE BEING REMOVED OR INSTALLED. G. SOME EXISTING SIMPLEX PULL STATIONS AND NOTIFICATION DEVICES SERVE THE SOME EXISTING SIMPLEX PULL STATIONS AND NOTIFICATION DEVICES SERVE THE DURESS ALARM SYSTEM AND ARE NOT A PART OF THE EXISTING FIRE ALARM SYSTEM. CONTRACTOR SHALL VERIFY THAT ALL DEVICES TO BE REMOVED ARE A PART OF THE FIRE ALARM SYSTEM. H. CONTRACTOR SHALL STORE, PROTECT AND TURN OVER ALL REMOVED SMOKE CONTRACTOR SHALL STORE, PROTECT AND TURN OVER ALL REMOVED SMOKE DETECTORS, NOTIFICATION DEVICES AND FACP COMPONENTS TO OWNER.
AutoCAD SHX Text
TAGGED NOTES :
AutoCAD SHX Text
1. NOT USED.NOT USED.
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
MECH.
AutoCAD SHX Text
MENS RR.
AutoCAD SHX Text
WOMENS RR.
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
CONFERENCE ROOM
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
COPY
AutoCAD SHX Text
STORAGE
AutoCAD SHX Text
ELEVATOR LOBBY
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
HALL
AutoCAD SHX Text
CORRIDOR
AutoCAD SHX Text
UPPER LANDING
AutoCAD SHX Text
DATE
AutoCAD SHX Text
DESCRIPTION OF REVISIONS
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
REVISION HISTORY OF THIS DRAWING
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
DATE
AutoCAD SHX Text
DESCRIPTION OF REVISIONS
AutoCAD SHX Text
RICE - FIRST FLOOR - DEMOLITION
AutoCAD SHX Text
SCALE: 3/16'' = 1'-0"
AutoCAD SHX Text E501D
AutoCAD SHX Text
AutoCAD SHX Text E501D
RICE - FIRST FLOOR - DEMOLITION
A&E FILE NO.
MLRCHECKED BY
DRAWN BY
DRAWING DATE
DRAWING INFORMATION
FRANKFORT, KENTUCKY
DIVISION OF ENGINEERING
DEPARTMENT FOR FACILITIES MANAGEMENT
FINANCE AND ADMINISTRATION CABINET
COMMONWEALTH OF KENTUCKY
DRAWING NO.
ACCOUNT NO.
PHASE
LEA
VDLF25
DECA REVIEWED
FOR INTENT ONLY
10411 Meeting Street
Prospect, Kentucky 40059 502 326.3085 f 502 326.2691 www.cmtaegrs.com
RTA
05/04/2026
07/10/26
KCH Fire Alarm Replacement Campus Wide, DJJ Lyndon
523-CAW7-KC12-00
AutoCAD SHX Text
GENERAL POWER/SYSTEMS NOTES :
AutoCAD SHX Text A. REFER TO THE ARCHITECT'S REFLECTED CEILING PLANS, ELEVATIONS, AND REFER TO THE ARCHITECT'S REFLECTED CEILING PLANS, ELEVATIONS, AND CASEWORK DETAILS FOR EXACT LOCATIONS OF ALL WALL AND CEILING MOUNTED ELECTRICAL DEVICES. B. CONTRACTOR SHALL FOLLOW BRANCH CIRCUITING LAY-OUT, AS INDICATED ON CONTRACTOR SHALL FOLLOW BRANCH CIRCUITING LAY-OUT, AS INDICATED ON THE FLOOR PLANS, WITH A MAXIMUM OF THREE (3) BRANCH CIRCUITS PER HOMERUN. EACH BRANCH CIRCUIT SHALL BE PROVIDED WITH A DEDICATED NEUTRAL CONDUCTOR. DEDICATED NEUTRAL CONDUCTORS SHALL BE CONSIDERED CURRENT CARRYING. IF ADDITIONAL CONDUCTORS ARE RAN IN THE SAME CONDUIT WITH THOSE INDICATED, CONTRACTOR SHALL DERATE ALL CURRENT CARRYING CONDUCTORS PER NEC 310.15(B)(3), AND UPSIZE CONDUIT AS REQUIRED PER NEC 300.17 AND ANNEX C. MULTIWIRE BRANCH CIRCUITS AS DEFINED IN NEC 100/210.4(CIRCUITS SHARING A COMMON NEUTRAL CONDUCTOR) SHALL NOT BE PERMITTED. C. IDENTIFY THE PANEL AND CIRCUIT NUMBER FOR ALL RECEPTACLES, SWITCHES, IDENTIFY THE PANEL AND CIRCUIT NUMBER FOR ALL RECEPTACLES, SWITCHES, ETC. IN AREA OF CONSTRUCTION. PROVIDE CLEAR ADHESIVE LABELS WITH BLACK LETTERING. IN HEALTHCARE FACILITIES, ENGRAVE EMERGENCY DEVICE COVERPLATES IN PATIENT CARE AREAS. MARK INSIDES OF ALL DEVICE BOXES WITH PANEL AND CIRCUIT NUMBERS. D. RECEPTACLES THAT ARE CONTROLLED BY AN AUTOMATIC MEANS SUCH AS RECEPTACLES THAT ARE CONTROLLED BY AN AUTOMATIC MEANS SUCH AS OCCUPANCY SENSOR OR ENERGY MANAGEMENT SYSTEM SHALL BE MARKED IN ACCORDANCE WITH NEC 406.3(E). E. LOCATIONS OF ELECTRICAL CONNECTIONS AND LOCAL DISCONNECTS SHALL BE LOCATIONS OF ELECTRICAL CONNECTIONS AND LOCAL DISCONNECTS SHALL BE COORDINATED WITH MECHANICAL AND PLUMBING CONTRACTORS TO ENSURE ACCESS AND WORKING CLEARANCE IS MAINTAINED PER NEC. NOTIFY OTHER TRADES OF REQUIRED CLEARANCE AREAS TO AVOID ROUTING OF OTHER SYSTEMS IN THESE AREAS. DO NOT INSTALL ELECTRICAL EQUIPMENT OVER EQUIPMENT NAMEPLATES OR ACCESS PANELS OR THROUGH ACCESS/MAINTENANCE CLEARANCES OF EQUIPMENT BY OTHER TRADES. F. REFER TO "SYSTEM INSTALLATION MATRIX" (ON SYSTEMS LEGEND SHEET) AND REFER TO "SYSTEM INSTALLATION MATRIX" (ON SYSTEMS LEGEND SHEET) AND SPECIFICATIONS FOR CONTRACTOR REQUIREMENTS OF EACH SYSTEM. G. THE CONTRACTOR SHALL ROUTE ALL "SYSTEM CONDUIT STUB-UPS" TO THE THE CONTRACTOR SHALL ROUTE ALL "SYSTEM CONDUIT STUB-UPS" TO THE NEAREST CORRIDOR CABLING PATH (SEE "STUB-UP" DETAILS). REFER TO CABLING PATH INSTALLATION DETAIL FOR ADDITIONAL REQUIREMENTS. H. CONTRACTOR SHALL PAINT ALL SYSTEMS CONDUIT STUB-UPS LIGHT BLUE FOR CONTRACTOR SHALL PAINT ALL SYSTEMS CONDUIT STUB-UPS LIGHT BLUE FOR SYSTEMS CABLING INTO THE CORRIDOR CABLING PATH. PROVIDE PULL STRINGS IN ALL NEW CONDUIT RUNS FOR SYSTEM CABLING INSTALLATION.
AutoCAD SHX Text
TAGGED NOTES :
AutoCAD SHX Text
1. NOT USED.NOT USED.
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
MECH.
AutoCAD SHX Text
MENS RR.
AutoCAD SHX Text
WOMENS RR.
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
CONFERENCE ROOM
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
COPY
AutoCAD SHX Text
STORAGE
AutoCAD SHX Text
ELEVATOR LOBBY
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
HALL
AutoCAD SHX Text
CORRIDOR
AutoCAD SHX Text
UPPER LANDING
AutoCAD SHX Text F
AutoCAD SHX Text F
AutoCAD SHX Text F
AutoCAD SHX Text F
AutoCAD SHX Text F
AutoCAD SHX Text F
AutoCAD SHX Text F
AutoCAD SHX Text F
AutoCAD SHX Text
EL
AutoCAD SHX Text
CM
AutoCAD SHX Text
CM
AutoCAD SHX Text
CM
AutoCAD SHX Text
CM
AutoCAD SHX Text
CM
AutoCAD SHX Text
CM
AutoCAD SHX Text
CM
AutoCAD SHX Text
CM
AutoCAD SHX Text
CM
AutoCAD SHX Text
CM
AutoCAD SHX Text
CM
AutoCAD SHX Text F
AutoCAD SHX Text
DATE
AutoCAD SHX Text
DESCRIPTION OF REVISIONS
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
REVISION HISTORY OF THIS DRAWING
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
DATE
AutoCAD SHX Text
DESCRIPTION OF REVISIONS
AutoCAD SHX Text
RICE - FIRST FLOOR - NEW WORK
AutoCAD SHX Text
SCALE: 3/16'' = 1'-0"
AutoCAD SHX Text E501F
AutoCAD SHX Text
AutoCAD SHX Text E501F
RICE - FIRST FLOOR - NEW WORK
A&E FILE NO.
MLRCHECKED BY
DRAWN BY
DRAWING DATE
DRAWING INFORMATION
FRANKFORT, KENTUCKY
DIVISION OF ENGINEERING
DEPARTMENT FOR FACILITIES MANAGEMENT
FINANCE AND ADMINISTRATION CABINET
COMMONWEALTH OF KENTUCKY
DRAWING NO.
ACCOUNT NO.
PHASE
LEA
VDLF25
DECA REVIEWED
FOR INTENT ONLY
10411 Meeting Street
Prospect, Kentucky 40059 502 326.3085 f 502 326.2691 www.cmtaegrs.com
RTA
05/04/2026
07/10/26
KCH Fire Alarm Replacement Campus Wide, DJJ Lyndon
523-CAW7-KC12-00
AutoCAD SHX Text
GENERAL DEMOLITION NOTES :
AutoCAD SHX Text A. THICK DOTTED LINES INDICATE ITEMS FOR REMOVAL(U.O.N.) AND THIN SOLID THICK DOTTED LINES INDICATE ITEMS FOR REMOVAL(U.O.N.) AND THIN SOLID LINES INDICATE EXISTING ITEMS TO REMAIN. B. THE CONTRACTOR SHALL MAINTAIN THE CONTINUITY OF EXISTING CIRCUITS THAT THE CONTRACTOR SHALL MAINTAIN THE CONTINUITY OF EXISTING CIRCUITS THAT CONTAIN DEVICES OR EQUIPMENT THAT ARE TO REMAIN. WHEN DEMOLITION OF AN ELECTRICAL DEVICE (OR CIRCUIT) IS INDICATED ON THE DRAWINGS: THE CONTRACTOR SHALL ENSURE THAT OTHER DEVICES OR EQUIPMENT "UPSTREAM" OR "DOWNSTREAM"ON THE CIRCUITS SHALL REMAIN IN "PRE-DEMOLITION" WORKING ORDER. "LEFT-OVER" CIRCUIT BREAKERS SHALL REMAIN, BE SWITCHED TO OFF POSITION, AND BE LABELED AS SPARES IN THEIR PANELS. PROVIDE NEW TYPE WRITTEN DIRECTORIES FOR ALL PANELS AFFECTED. C. LOCATIONS OF DEVICES, CONNECTIONS, ETC., INDICATED ON THIS DRAWING WERE LOCATIONS OF DEVICES, CONNECTIONS, ETC., INDICATED ON THIS DRAWING WERE TAKEN FROM VARIOUS SOURCES. THEY ARE DIAGRAMMATIC ONLY AND ARE SUBJECT TO VARIATION FROM EXISTING CONDITIONS. CERTAIN EXISTING ELEMENTS MAY NOT BE INDICATED AT ALL. THE CONTRACTOR PROPOSING TO DO ANY PART OF THE WORK INDICATED HEREON SHALL VISIT THIS SITE AND DETERMINE TO HIS SATISFACTION THAT THEY MAY COMPLETE ALL WORK REQUIRED FOR THE BID WHICH HE PROPOSES. D. COORDINATE DISPOSAL OF ALL FIXTURES, DEVICES, ETC. (INDICATED FOR COORDINATE DISPOSAL OF ALL FIXTURES, DEVICES, ETC. (INDICATED FOR DEMOLITION) WITH OWNER. E. CONTRACTOR SHALL PATCH AND REPAIR ALL EXISTING WALLS AS REQUIRED CONTRACTOR SHALL PATCH AND REPAIR ALL EXISTING WALLS AS REQUIRED WHERE NEW FLUSH MOUNTED DEVICES ARE BEING REMOVED. F. CONTRACTOR SHALL PATCH AND REPAIR DUCTWORK AS REQUIRED WHEREVER CONTRACTOR SHALL PATCH AND REPAIR DUCTWORK AS REQUIRED WHEREVER DUCT SMOKE DETECTORS ARE BEING REMOVED OR INSTALLED. G. SOME EXISTING SIMPLEX PULL STATIONS AND NOTIFICATION DEVICES SERVE THE SOME EXISTING SIMPLEX PULL STATIONS AND NOTIFICATION DEVICES SERVE THE DURESS ALARM SYSTEM AND ARE NOT A PART OF THE EXISTING FIRE ALARM SYSTEM. CONTRACTOR SHALL VERIFY THAT ALL DEVICES TO BE REMOVED ARE A PART OF THE FIRE ALARM SYSTEM. H. CONTRACTOR SHALL STORE, PROTECT AND TURN OVER ALL REMOVED SMOKE CONTRACTOR SHALL STORE, PROTECT AND TURN OVER ALL REMOVED SMOKE DETECTORS, NOTIFICATION DEVICES AND FACP COMPONENTS TO OWNER.
AutoCAD SHX Text
TAGGED NOTES :
AutoCAD SHX Text
1. NOT USED.NOT USED.
AutoCAD SHX Text
MECH. RM.
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
MECH. RM.
AutoCAD SHX Text
MENS RR.
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
WOMENS RR.
AutoCAD SHX Text
ELEV. LOBBY
AutoCAD SHX Text
DATE
AutoCAD SHX Text
DESCRIPTION OF REVISIONS
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
REVISION HISTORY OF THIS DRAWING
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
DATE
AutoCAD SHX Text
DESCRIPTION OF REVISIONS
AutoCAD SHX Text
RICE - SECOND FLOOR - DEMOLITION
AutoCAD SHX Text
SCALE: 3/16'' = 1'-0"
AutoCAD SHX Text E502D
AutoCAD SHX Text
AutoCAD SHX Text E502D
RICE - SECOND FLOOR - DEMOLITION
C
SD
SD
BL
P
UON
EM
CFOI
OFOI
CFCI
OFCI
T
ANALOG CLOCK
C/S
J
DESCRIPTION
DP
S
S
X
S
S 3
S D
SK
PC
S
S 4
S
U
SL
N
OS
OS
SPL
IL
GROUND FAULT PROTECTED DUPLEX WITH WEATHER-
PROOF "WHILE IN USE" TYPE DIE-CAST METAL
COVERPLATE WITH LOCKABLE ENCLOSURE AT
OUTLET - SEE SPECIFICATIONS
WP
ER
ELECTRIC WATER COOLER RECEPTACLE:
COORDINATE EXACT LOCATION WITH PLUMBING
CONTRACTOR TO CONCEAL OUTLET(S) BEHIND
COOLER, PROVIDE MULTIPLE RECEPTACLES WHERE
REQUIRED BY MANUFACTURER, PROVIDE READILY
ACCESSIBLE DEAD FRONT GFCI DEVICE AT 18"
ADJACENT TO WATER COOLER FOR PROTECTION OF
WATER COOLER RECEPTACLE(S)
EWC
AUDIO/VIDEO INTERCOM STATION: MASTER WITH
SELECTIVE DOOR CONTROLS, POWER SUPPLIES & DOOR
RELAY CONTACTS AS REQUIRED FOR OPERATION OF
ANY DOOR IN THE SYSTEM AND VIEWING OF ANY
AUDIO/VIDEO INTERCOM REMOTE ON THE SYSTEM.
AIPHONE#AX-MV W/DESK STAND - COLOR BY ARCHITECT.
SAME AS ''IM'' EXCEPT WALL MOUNTED W
DOOR CONNECTION. PROVIDE ALL CONDUIT, JUNCTION
BOXES, CABLING, POWER, ETC. AS REQUIRED FOR NEW
DOOR CONTROLS. REFER TO SECURITYS DRAWINGS
FOR FURTHER REQUIREMENTS
DOOR RELEASE CARD READER STATION. PROVIDE
ANY ADDITIONAL ROUGH-IN FOR ''EMERGENCY
RELEASE'' OPERATOR STATIONS AS REQUIRED.
AUTOMATIC DOOR CONNECTION (MAY ALSO HAVE
ELECTRIC STRIKE/MAG-LOCK/ELECTRIFIED PANIC
CONNECTION - SEE ARCHITECTURAL HARDWARE
SPECIFICATIONS)
FLOORBOX, COMBINATION POWER AND LOW
VOLTAGE, REFER TO FLOORBOX SCHEDULE
B
SS
KEYED, LOCKED PULL STATION : DOUBLE ACTION.
STATION SHALL ONLY BE OPERABLE VIA KEY IN
POSSESSION OF STAFF.
CDCARBON MONOXIDE DUCT DETECTOR
POWER SUPPLY/CONTROL FOR AUDIO/VISUAL DEVICES
SAME AS ''CR'' EXCEPT MULLION MOUNT M
SLASH THROUGH ANY DEVICE INDICATES MOUNTING
ABOVE COUNTERTOP 4" ABOVE BACKSPLASH, OR AT 46"
WHERE NO COUNTER IS PRESENT
OVERHEAD PROJECTOR: PROVIDE DUPLEX
RECEPTACLE, ONE DATA, HDMI, 3.5mm AUDIO, AND
VGA OUTLET ON (3) PLATES
CCTV CAMERA: CEILING MOUNT DOME
WP
''DOG-HOUSE'' TYPE TWIN DUPLEX RECEPTACLE
WITH ONE DUPLEX RECEPTACLE ON BOTH SIDES
AUDIO/VIDEO INTERCOM STATION: REMOTE WITH
FLUSH-MTD S.S. ENCLOSURE. AIPHONE #AX-DVF.
SVS
VS
LV
PILOT LIGHT SWITCH (ILLUMINATED WHEN LOAD IS ON)
ILLUMINATED HANDLE LIGHT SWITCH (ILLUMINATED
WHEN LOAD IS OFF)
EMERGENCY AUTOMATIC TRANSFER SWITCH
FOR LIGHTING CONTROLS (REFER TO DETAIL)
FILLED CENTER BAR INDICATES INTEGRAL GROUND
FAULT PROTECTION (GFCI)
GANG RECEPTACLE IN COMBINATION WITH SWITCH
(PROVIDE DIVIDER IF LIGHTING CIRCUIT IS 277V)
NON-REVERSING MOTOR STARTER SNAP SWITCH
CONTRACTOR FURNISHED OWNER INSTALLED
CONTRACTOR FURNISHED CONTRACTOR INSTALLED
OWNER FURNISHED OWNER INSTALLED
OWNER FURNISHED CONTRACTOR INSTALLED
FLUSH MOUNTED REMOTE ALARM INDICATING
STATION/TEST SWITCH
CONNECTION TO SPRINKLER TAMPER
SWITCH WITH ADDRESSABLE MODULE
CONNECTION TO SPRINKLER FLOW
SWITCH WITH ADDRESSABLE MODULE
PHOTO-ELECTRIC SMOKE DETECTOR FOR PATIENT
ROOM MONITORING (SEE RISER)
PHOTO-ELECTRIC SMOKE DETECTOR
MAIN CONTROL PANEL CENTRAL PROCESSING
UNIT (CPU)
DOOR ALARM/POSITION SWITCH
DOOR POWER SUPPLY
DOOR DELAYED EGRESS/ELECTRIFIED PANIC
MECHANISM
TELEVISION SYSTEM OUTLET WITH DUPLEX
RECEPTACLE, COORDINATE LOCATION WITH WALL
BRACKET WHERE APPLICABLE
SURGICAL LIGHT INTENSITY CONTROL
LIGHT SWITCH:GENERAL PURPOSE
AS NOTED
AS NOTED
LIGHT SWITCH FOR UNDER-CABINET LIGHTS
6'-6'' TO
TOP
46" TO
LEVER
46" TO
LEVER
DESCRIPTION
PULL STATION : DOUBLE ACTION
AUDIO-ONLY NOTIFICATION APPLIANCE
VISUAL-ONLY NOTIFICATION APPLIANCE
AUDIO/VISUAL NOTIFICATION APPLIANCE
BELL / LIGHT
BELL ONLY
HEAT DETECTOR
CARBON MONOXIDE ALARM: SINGLE STATION
W/SOUNDER BASE
CARBON MONOXIDE AUDIO/VISUAL NOTIFICATION
APPLIANCE
DOOR HOLDER : WALL TYPE
DOOR HOLDER : CLOSURE TYPE
DUCT SMOKE DETECTOR
PRESSURE SWITCH
REMOTE L.C.D. FIRE ALARM ANNUNCIATOR
POST INDICATOR VALVE
ISOLATION MODULE
H.V.A.C. SMOKE DAMPER CONNECTION
UNLESS OTHERWISE NOTED
INDICATES EMERGENCY POWER
ELAPSED TIMER
SURFACE PLUG-MOLD
SPECIAL OUTLETS
HD
ABV CLG
CM
F
DH
ABV DOOR DH
ABV CLG DD
FS
TS
PS
46"
I
ZONE ADDRESSABLE MODULE Z
SM
ABBREVIATIONS
DESCRIPTION
XLSL
STRIP FIXTURE
CROSS-HATCHING INDICATES LIGHT IS POWERED
FROM THE EMERGENCY-CRITICAL BRANCH
PARALLEL-HATCHING INDICATES LIGHT IS POWERED
FROM THE EMERGENCY-LIFE SAFETY BRANCH
PANEL FURNITURE
POWER OUTLETS
SIMPLEX RECEPTACLE
DUPLEX RECEPTACLE-SAFETY TYPE,
TAMPER-RESISTANT
DUPLEX RECEPTACLE
QUADRUPLEX RECEPTACLE
JUNCTION BOX, CEILING OR WALL
VOLTAGE/1PH RECEPTACLE, AS NOTED
VOLTAGE/3PH RECEPTACLE, AS NOTED
SS INDICATES SURGE SUPPRESION TYPE OUTLET(S)
EXAM LIGHT SWITCH
NIGHT LIGHT SWITCH WITH CONSTANTLY
ILLUMINATED HANDLE
DIMMER SWITCH
THREE-WAY SWITCH
FOUR-WAY SWITCH
KEYED SWITCH
OCCUPANCY OR VACANCY SENSOR SWITCH
OCCUPANCY OR VACANCY SENSOR, CEILING MOUNT
LOW VOLTAGE MOMENTARY SWITCH
PHOTO-CELL AS NOTED
SURGICAL/EXAM LIGHT
EXIT LIGHT (CEILING, END, WALL MOUNT)
CLOCKS
ET
LIGHTING
REFER TO LUMINAIRE SCHEDULE FOR EXACT FIXTURE
SPECIFICATIONS, MOUNTING HEIGHTS, ETC.
SPECIAL VIDEO SYSTEM SIGNAL INPUT
SECURITY PANIC ALARM
SECURITY INTERCOM
SECURITY ACCESS CONTROL
SECURITY CCTV VIDEO SURVEILLANCE
PANIC ALARM BUTTON
PANIC ALARM ANNUNCIATOR
PANIC ALARM POWER SUPPLY CABINET
DOOR RELEASE KEYSWITCH STATION
DOOR RELEASE KEYPAD STATION
MOTION SENSOR DOOR CONTROL
REMOTE DOOR RELEASE PUSH-BUTTON
CCTV CAMERA: WALL MOUNT DOME
CCTV POWER SUPPLIES/CONTROL PANEL 46"
46"
DOOR
FRAME
ABV DOOR
8" ACT
DESCRIPTION
WALL, CLG
80"
CLG
CLG
CLG
WALL
54"
46"
46"
46"
46"
46"
46"
46"
46"
46"
46"
46"
46"
46"
1'-6"
1'-6"
1'-6"
1'-6"
46"
1'-6"
1'-6"
ON CNTR.
2'-2"
CLG
AS NOTED
46"
46"
18''
46"
46"
CLG
46"
6'-0''
46"
46"
CEIL.
CLG
7'-0"
S
CLG
S
FLOOR
S
S
S M
TELEVISION SPLITTERS/AMPLIFIERS/DISTRIBUTION
TELEVISION
46" TV-HE
D R
A W
IN
G
S
Y M
B O
L
AMBER STROBE 80''
SURFACE OR SUSPENDED CEILING FIXTURE (SLASH
INDICATES RECESSED)
POLE MOUNTED AREA LIGHT
EMERGENCY BATTERY WALL-PACK
WALL MOUNT FIXTURE ,
FLOODLIGHT
V
A
F
F K
F
GRAPHICS DISPLAY TERMINAL
RI
INDICATES VANDAL-PROOF POLYCARBONATE COVER,
VANDAL PROOF COVERS SHALL BE UL LISTED FOR USE
WITH THE SPECIFIC DEVICE THEY ARE PROTECTING
PC
80"
CLG
WALL
WALL
7'-6''
FIREMAN'S PHONE JACK FP
ADDRESSABLE RELAY MODULE R
WALL
ACCESS CONTROL POWER SUPPLIES/CONTROL PANEL 46"
46"
ABV CLG
ELECTRIC STRIKE AT LATCH
MAGNETIC LOCK(S) ABV DOOR
INDICATES EXTERIOR CAMERA RATED FOR
CONDITIONS, WET LOCATION LISTED, WITH
AUXILLARY HEATER
PTZINDICATES CAMERA WITH PAN/TILT/ZOOM FUNCTION
FLOORBOX, POWER ONLY, AS SCHEDULED FLOOR
FIRE RATED POKE-THRU FLOOR BOX, COORDINATE
EXACT COVER REQUIREMENTS WITH ARCHITECTURAL
FINISHES, DEVICES AS SCHEDULED
DESCRIPTION
K
DB
DB
WP
DOORBELL PUSHBUTTON STATION, PROVIDE COMPLETE
WITH TRANSFORMER (MOUNT ABOVE CEILING IN
CORRIDOR NEAR PUSH-BUTTON) AND ALL
ACCESSORIES, POWER FROM NEAREST AVAILABLE 120V
NORMAL POWER GENERAL RECEPTACLE CIRCUIT,
NUTONE OR EQUAL
DOORBELL AUDIO/VISUAL STATION, PROVIDE PROVIDE
CONNECTION TO PUSHBUTTON STATION IN AREA.
COORDINATE EXACT AUDIO SOUND (CHIME, BUZZER,
ETC.) DESIRED WITH OwNER/ARCHITECT, NUTONE OR
EQUAL
PLUMBING FIXTURE ELECTRIC EYE TRANSFORMER
CONNECTION. TRANSFORMER SHALL BE 120V-24V.
MOUNT ABOVE SUSPENDED ACCESSIBLE CEILING IN J-
BOX. PROVIDE ADDITIONAL TRANSFORMERS OF SAME
TYPE AS/IF NEEDED
PROVIDE CONNECTION TO HAND DRYER (SEE
ARCHITECTURAL SPECIFICATIONS)
VERIFY WITH
ARCHITECT
C
INDICATES MOUNTING ABOVE COUNTER-TOP,
2" ABOVE BACKSPLASH, NO HIGHER THAN 48''
WG
WIREGUARD - PROVIDE MANUFACTURER'S
SPECIFIC GUARD FOR DEVICE NOTED
BOX ON ANY DEVICE INDICATES SURFACE MOUNTED
BACKBOX/WIREMOLD
CONDUIT CONCEALED IN WALLS OR IN CEILING
SPACE: ARROW(S) INDICATE(S) HOME RUN & #
OF CIRCUITS: HASHMARKS INDICATE # OF
CONDUCTORS. DASHED LINE INDICATES
CONDUIT BELOW FLOOR.
WIREWAY WITH REMOVABLE COVER (SIZE AS NOTED)
PANELBOARD, SURFACE OR FLUSH MOUNTED,
HATCHING INDICATES EMERGENCY
EQUIPMENT TAG, REFER TO EQUIPMENT SCHEDULE
MECHANICAL EQUIPMENT DESIGNATOR
(SEE MECH. SCHEDULES)
EQUIPMENT HARDWIRE CONNECTION (SEE DETAIL)
KITCHEN EQUIPMENT OUTLET COUPLING
CONNECTION (SEE DETAIL)
AS SHOWN
AS SHOWN
AS NOTED
AS SHOWN
MISCELLANEOUS
DISCONNECT SWITCH
MAGNETIC STARTER
MAGNETIC COMBINATION STARTER
ENCLOSED FLUSH MTD. CIRCUIT BREAKER
WEATHERPROOF - NEMA-3R, WET LOCATION LISTED.
PROVIDE COVERS, RATINGS, ETC, AS SUITABLE FOR
OUTDOORS.
TRENCH DUCT (SIZE AS NOTED)
PUSHBUTTON STATION
FLEXIBLE CONDUIT
TRANSFORMER
TAGGED NOTE
REVISION TAG
WIRE BASKET CABLE TRAY, SIZE AS NOTED
LOW VOLTAGE CABLE PATH
5'-0"
5'-0"
5'-0"
5'-0"
46"
46"
7'-6''
6'-6'' TO TOP
XPEXPLOSION PROOF - PROVIDE WIRING METHODS,
ENCLOSURES, RATINGS, ETC. AS SUITABLE FOR
HAZARDOUS LOCATION.
SURGE PROTECTION DEVICE
GENERATOR ANNUNCIATOR PANEL - SEE
SPECIFICATIONS
46"
THERMOSTAT PROVIDED BY MECHANICAL
CONTRACTOR, ELECTRICAL CONTRACTOR SHALL
PROVIDE BACK-BOX CONDUIT STUB-UP, REFER TO
MECHANICAL DRAWINGS FOR LOCATIONS
PANEL FURNITURE DUPLEX RECEPTACLE. PROVIDE
ALL WIRING AS REQUIRED, COORDINATE EXACT
INSTALLATION REQUIREMENTS AND LOCATIONS WITH
OWNER'S PANEL FURNITURE VENDOR
PANEL FURNITURE DATA/VOICE OUTLET. PROVIDE ALL
WIRING AS REQUIRED, COORDINATE EXACT
INSTALLATION REQUIREMENTS AND LOCATIONS WITH
OWNER'S PANEL FURNITURE VENDOR
POWER CONNECTION TO PANEL FURNITURE, PROVIDE
SEAL-TIGHT CONDUIT CONNECTION FROM RECESSED
WALL BOX TO PANEL FURNITURE, PROVIDE FINAL
CONNECTIONS TO PANEL FURNITURE AS REQUIRED BY
PANEL FURNITURE VENDOR
1'-6"
COMBINATION POWER AND LOW VOLTAGE CONNECTION
TO PANEL FURNITURE, PROVIDE SEAL-TIGHT CONDUIT
CONNECTION FROM RECESSED WALL BOX TO PANEL
FURNITURE, PROVIDE FINAL CONNECTIONS TO PANEL
FURNITURE AS REQUIRED BY PANEL FURNITURE
VENDOR
C A
B L
IN
G
/C O
N D
U C
T O
R S
O
F O
I
C A
B L
IN
G /C
O N
D U
C T
O R
S
O F
C I
C A
B L
IN
G
/C O
N D
U C
T O
R S
C
F C
I
IT
E
M U
S E
D O
N P
R O
J E
C T
D E
V
IC
E S
O
F C
I
D E
V
IC
E S
C
F C
I
SYSTEM D
E
V
IC
E S
O
F O
I
RF
SECURITY: PANIC ALARM
SECURITY: ACCESS CONTROL
SECURITY: INTERCOM
SECURITY: CCTV
PATIENT ROOM MOTION DETECTION
SYSTEM
RESPONSIBILITY
MATRIX
OVERHEAD PAGING
FIRE ALARM
TELEVISION
DATA PROCESSING
TELEPHONE
LOCAL SOUND
TELEMETRY
RF TRACKER
PATIENT DOOR TOP LIGATURE ALARM
NURSE CALL
SYSTEM RESPONSIBILITY GENERAL NOTES:
A. REFER TO VENDOR DRAWINGS FOR COMPLETE SCOPE OF WORK RELATING TO
VENDOR-FURNISHED EQUIPMENT. ALL WORK INDICATED ON VENDOR DRAWINGS
SHALL BE INCLUDED BY THE CONTRACTOR.
B. REFER TO ARCHITECTURAL DOOR HARDWARE SPECIFICATIONS FOR ACCESS
CONTROL DEVICE SPECIFICATIONS AND FURTHER REQUIREMENTS.
C. PROVIDE BACKBOXES AND CONDUIT WITH PULL-STRINGS FOR ALL SYSTEMS.
CONTRACTOR SHALL VERIFY BACKBOX SIZES, CONDUIT, ETC. AND EXACT
INSTALLATION LOCATIONS/REQUIREMENTS WITH SUCCESSFUL VENDORS OF ALL
SYSTEMS PRIOR TO CONSTRUCTION.
D. AT ALL SYSTEMS EQUIPMENT CABINET/TERMINAL BOARD LOCATIONS,
CONTRACTOR SHALL PROVIDE SIZE AND NUMBER OF CONDUIT STUB-OUTS TO
CABLE PATHS AS REQUIRED BY SYSTEM VENDORS, TERMINATE CONDUITS AT
CABINETS/ON BACKBOARDS AS REQUIRED. COORDINATE EXACT REQUIREMENTS
WITH APPROPRIATE VENDORS PRIOR TO CONSTRUCTION.
E. REFER TO SPECIFICATIONS FOR REQUIREMENTS APPLICABLE TO ALL SYSTEMS
INCLUDING CABLING, CABLE MANAGEMENT, INSTALLATION, GROUNDING, TESTING,
LABELING, ETC.
F. WHERE INDICATED AS CFCI, THE CONTRACTOR SHALL PROVIDE THE SYSTEM
COMPLETE, INCLUDING ALL ROUGH-INS, CABLING, DEVICES, POWER, ETC. THE
CONTRACTOR SHALL CONTACT THE LISTED VENDOR FOR PRICING PRIOR TO BID.
ALL SYSTEMS SHALL MATCH EXISTING FACILITY STANDARDS AND BE FULLY
COMPATIBLE WITH ANY EXISTING SYSTEMS. ALL SYSTEM VENDORS SHALL
COORDINATE EXACT SYSTEM REQUIREMENTS WITH OWNER PRIOR TO BID. NEW
COMPONENTS SHALL BE INTERCONNECTED WITH EXISTING SYSTEMS WHERE
POSSIBLE. ALL NEW SYSTEM DESIGNS AND PROGRAMMING SHALL BE
COORDINATED WITH THE OWNER PRIOR TO ORDERING. ALL PROGRAMMING SHALL
BE INCLUDED AS REQUIRED BY THE OWNER. PROVIDE 4 HOURS OF TRAINING FOR
EACH SYSTEM.
PPPOWER POLE AS NOTED
84''
DIGITAL CLOCK: SINGLE FACE
DIGITAL CLOCK: DUAL FACE
CLOCK SYSTEM HEAD END
84''
84''
84''
SECURITY INTRUSION DETECTION
MOTION DETECTOR CLG
MOTION DETECTOR KEYPAD CONTROLLER 46"
SECURITY SYSTEM HEAD END 46"
SWITCHES
MOMENTARY CONTACT SWITCH
HAND-OFF-AUTO 3-POSTION SWITCH
TIMER SWITCH
S MC
S HOA
S T
46"
46"
46"
M
SV
S
S
V
1'-6''
46"PAGING SYSTEM AMPLIFIER/TUNER CABINET
PAGING MICROPHONE
WALL VOLUME CONTROL
PAGING SPEAKER: WALL
PAGING SPEAKER W/ VOLUME CONTROL
PAGING SPEAKER: CEILING CLG
CLG
8'-0"
46"
OVERHEAD PAGING
VANDAL PROOF / WEATHERPROOF WALL
MOUNTED PAGING SPEAKER. QUAM VP1
EXTERIOR VANDAL PROOF / WEATHERPROOF WALL
MOUNTED PAGING SPEAKER, SHALL BE PAINTED
COLOR SELECTED BY ARCHITECT/OWNER. QUAM VP6
RECESSED WALL MOUNTED PAGING SPEAKER
DUKANE 5A606 SPEAKER. ATLAS 417-8WD
WALL MOUNTED PAGING HORN
CALL INITIATION STATION
LCD WALL DISPLAY
8'-0"
9'-0"
SEE
FLOOR
PLANS
SEE
FLOOR
PLANS
46"
S
H
S
S
C
LD
R
EXT.
FIRE ALARM
WP
RADIOLOGY EQUIPMENT
SECURITY INTRUSION DETECTION
PHYSIOLOGICAL/TELEMETRY MONITORING
E,EMINDICATES EMERGENCY POWER
SYSTEM
SYMBOL
PUSH-TO-EXIT BUTTON 46"
SURFACE WIRE-MOLD
PE
PA
MK
MD
SEC-M
2DC
DC
CLOCK
GEN-A
SPD
J
J
ML
ES
SEC-A
GDT
AS
NAC
CC
CC
CR
RR
DP
DA
IM
KP
IR
KS
MS
DC
CR
DS
AD
IM
PIV
FAA
FACP
SEC-P
PA
PB
SEC-C
J
T
FP
D R
A W
M
B O
L
D R
A W
M
B O
L
D R
A W
M
B O
L
AS SHOWNLADDER CABLE TRAY, SIZE AS NOTED
AS SHOWNSOLID BOTTOM CABLE TRAY, SIZE AS NOTED
EQUIP-1
PLUMBING FIXTURE SOLENOID VALVE/ELECTRIC EYE
SENSOR CONNECTION. COORDINATE EXACT
CONNECTION REQUIREMENTS WITH MANUFACTURER.
GROUND
NEUTRAL
PHASE
FIREMAN'S KNOX BOX CONNECTION KB
REMOTE FIRE ALARM ANNUNCIATOR W/ MICROPHONE 54" FAAM
WALL, CLG
WALL, CLG V
A
F
CM
INDICATES CHIME AUDIBLE NOTIFACTION CH
DEVICE USED FOR ELEVATOR CONTROL EL
FIRE ALARM CONTROL EXTENDER EXT
4'-6''
TRANSPONDER CABINET 46" TRAN
BE , BR
PROJECTED BEAM SMOKE DETECTOR; EMITTER
(BE) AND RECEIVER (BR)
FLOOR
AV
AUDIO/VISUAL SYSTEM OUTLET WITH DUPLEX
RECEPTACLE, REFER TO ASSOCIATED DETAIL FOR
ADDITIONAL INFORMATION
1'-6"
COMBINATION POWER AND DATA OUTLET LOCATION,
REFER TO ASSOCIATED DETAIL FOR ADDITIONAL
INFORMATION
1'-6"
COMBINATION POWER AND DATA OUTLET LOCATION,
GFCI DUPLEX RECEPTACLE, REFER TO ASSOCIATED
DETAIL FOR ADDITIONAL INFORMATION
1'-6"
1'-6"
FF
DEAD FRONT GFCI DEVICE, LABEL AND INSTALL IN
READILY ACCESSIBLE LOCATION
FILLED OUTER BARS INDICATES INTEGRAL INTEGRAL
USB OUTLETS IN ADDITION TO POWER RECEPTACLES
1'-6"
, J
VARIABLE FREQUENCY DRIVE 5'-0"
CIRCLE ON ANY DEVICE INDICATES DEVICE FED FROM
STUB UP CONDUIT
MOTOR CONNECTION, REFER TO EQUIPMENT
CONNECTION SCHEDULE
DUPLEX RECEPTACLE, CEILING MOUNTED CLG
PAY
#D/#V
#D
INTERMEDIATE DISTRIBUTION FRAME - REFERENCE
DATA SYSTEM SCHEMATICS AND DETAILS FOR
ADDITIONAL REQUIREMENTS
MAIN DISTRIBUTION FRAME - REFERENCE DATA
SYSTEM SCHEMATICS AND DETAILS FOR ADDITIONAL
REQUIREMENTS
WIRELESS ACCESS POINT WITH PROVISIONS FOR (1
DATA OUTLET FOR ANTENNA. PROVIDE A COMPLETE
DATA OUTLET WITH FACEPLATE ABOVE CEILING,
MOUNTED AT AN ACCESSIBLE HEIGHT NO MORE THAN
24" ABOVE CEILING. AT EACH OUTLET, PROVIDE A 20'
COIL OF CABLE AHEAD OF THE OUTLET FOR
ADJUSTMENT OF FINAL OUTLET LOCATION. THE
CONTRACTOR SHALL COORDINATE EXACT LOCATIONS
WITH THE OWNER AND ADJUST OUTLET LOCATIONS AT
SUBSTANTIAL COMPLETION TO ACCOMMODATE
OWNER'S WAP LOCATIONS. WAP'S ARE OWNER-
FURNISHED, OWNER-INSTALLED
TELECOMMUNICATIONS SYSTEM BACKBOARD. PROVIDE
96''H x 3/4''D FIRE-RETARDENT PLYWOOD BACKBOARD
WITH TWO (2) COATS OF NON-C0NDUCTIVE, FIRE-
RETARDANT LIGHT GRAY PAINT, #3/0 TO GROUND BAR AT
MAIN SERVICE SWITCHBOARD, 30-PT GROUND BAR AND
A 6'-0'', #3 AWG PIGTAIL AT BACKBOARD. INSTALL BOARD
AT 2' AFF. (LENGTH OF BOARD AS INDICATED ON FLOOR
PLAN)
WAP
DATA OUTLET : NUMBER BESIDE OUTLET
INDICATES NUMBER OF DATA JACKS
VOICE OUTLET : NUMBER BESIDE OUTLET
INDICATES NUMBER OF VOICE JACKS
COMBINATION OUTLET : NUMBER BESIDE OUTLET
INDICATES NUMBER OF DATA/VOICE JACKS
TELEMETRY ANTENNA
RF TRACKER ANTENNA
DATA / VOICE
AS REQ'D.OUTLET (VOICE ONLY) : PAYPHONE TYPE
1'-6"
1'-6"
1'-6"
CLG
CLG
#V
MDF
IDF
TEL
CONDUIT UP
CONDUIT DOWN
GROUND BUS BAR ON INSULATED STANDOFFS 2'-0''
AS SHOWNBUS DUCT, AMPERAGES AS NOTED
M O
U N
T
H E
IG
H
T
T O
N T
E R
O F
B O
X
M O
U N
T
IG
H
T
N T
E R
O F
B O
X
M O
U N
T
IG
H
T
N T
E R
O F
B O
X
M O
U N
T
IG
H
T
N T
E R
O F
B O
X
PROVIDE FIRE ALARM CONNECTION TO DOOR INDICATED
SA COORDINATED WITH SECURITY VENDOR.
FDDOOR
DBDURESS BUTTON
ARCHITECTSK E R S E Y A N D K E R S E Y
RTA DATE
DECA LOG #
A&E FILE NO.
CHECKED BY
DRAWN BY
DRAWING DATE
DRAWING INFORMATION
DRAWING NO.
AS BUILT DATE
PHASE
DATEDESCRIPTION OF REVISIONS
REVISION HISTORY OF THIS DRAWING
DATEDESCRIPTION OF REVISIONS
FRANKFORT, KENTUCKY
DIVISION OF ENGINEERING AND CONTRACT ADMINISTRATION
KENTUCKY DEPARTMENT OF JUVENILE JUSTICE
FINANCE AND ADMINISTRATION CABINET
COMMONWEALTH OF KENTUCKYACCOUNT NO(S).
Fax 502 585 2728 kerseyandkersey.com
Louisville, KY 40204
Tel 502 583 0094
839 East Gray Street Suite 207
Lexington, KY 40507
201 West Short Street Commiskey, IN 47227
Tel 812 873 1287
9307 West 1000 North
Tel 859 303 8439
LOUISVILLE, KENTUCKY LEXINGTON, KENTUCKY MADISON, INDIANA
DJJ - LYNDON RENOVATION
8711 LAGRANGE ROAD
LOUISVILLE, KY
2259 / 2361
523-CBOB-LY-0000
523-CAEC-JF-01-00
DJJ Lyndon Facilities:
DJJ Control Room:
CONFORMED SET 11-15-24
/1 /2
:0
:2
P
M
E100
ELECTRICAL LEGEND
06/07/2024
RTA
GTJ/GTH
MLR
NO SCALE
ELECTRICAL LEGEND
GENERAL NOTES (LEGEND):
A. EACH CONTRACTOR, PROPOSER, SUPPLIER AND/OR MANUFACTURER SHALL REFER TO ALL DOCUMENTS PERTAINING TO THIS PROJECT AND COORDINATE ACCORDINGLY SO AS TO ENSURE ADEQUACY OF FIT, COMPLIANCE WITH SPECIFICATIONS, PROPER VOLTAGE AND CURRENT CHARACTERISTICS TO AVOID CONFLICT
WITH ANY OTHER BUILDINGS SYSTEMS. VERIFY SAME WITH SHOP DRAWINGS.
B. ADDITIONAL ELECTRICAL REQUIREMENTS MAY BE SHOWN ON PLANS FROM OTHER DISCIPLINES IN THIS SET. IT IS THE CONTRACTOR’S RESPONSIBILITY TO REVIEW ALL PLANS AND SPECIFICATIONS FOR A COMPLETE
UNDERSTANDING OF THE PROJECT REQUIREMENTS.
C. WORK SHALL BE IN ACCORDANCE WITH THE LATEST EDITION OF ALL LOCAL, STATE, AND NATIONAL CODES.
INCLUDING BUT NOT LIMITED TO NFPA 70 (NEC), NFPA 72, INTERNATIONAL BUILDING CODES, ETC. IN ADDITION, OBSERVE ALL APPLICABLE RULES AND REGULATIONS THAT MAY APPLY TO THE WORK UNDER THIS CONTRACT FROM CITY, COUNTY, LOCAL, STATE, FEDERAL, MUNICIPALITY, UTILITY COMPANY, OSHA, ETC.
D. CONTRACTOR SHALL FOLLOW SEISMIC RESTRAINT AND DESIGN REQUIREMENTS CONTAINED IN LATEST ADOPTED STATE AND INTERNATIONAL BUILDING CODES, WITH ALL AMENDMENTS AS ADOPTED BY THE CURRENT LEGISLATION. REFER TO ELECTRICAL AND STRUCTURAL SPECIFICATIONS FOR ADDITIONAL INFORMATION.
E. ADVISE THE ENGINEER OF ANY CONFLICTS, ERRORS, OMISSIONS, ETC. AT LEAST TEN DAYS PRIOR TO BID DATE, TO
ALLOW CLARIFICATION BY WRITTEN ADDENDUM.
F. WHERE CONFLICTS ARE FOUND BETWEEN DRAWINGS, DETAILS, OR SPECIFICATIONS, THE MORE STRINGENT
REQUIREMENT SHALL APPLY. NOTIFY ARCHITECT OF DISCREPANCY IN WRITING.
G. DEVIATION FROM SPECIFICATIONS OR PLANS REQUIRES PRIOR WRITTEN APPROVAL FROM THE ENGINEERS AND
MUST BE SUBMITTED IN WRITING NO LATER THAN TEN DAYS PRIOR TO THE BID DATE.
H. ALL ELECTRICAL COMPONENTS OR EQUIPMENT SHALL BE LISTED AND LABELED BY UNDERWRITER'S LABORATORIES OR OTHER APPROVED LISTING AGENCY. APPROVAL AND LABELING OF INDIVIDUAL COMPONENTS ON AN ASSEMBLY IS NOT ACCEPTABLE AS MEETING THIS REQUIREMENT, UNLESS WAIVED BY THE ENGINEER IN
WRITING.
I. ALL MATERIALS FURNISHED AND ALL WORK INSTALLED SHALL COMPLY WITH THE CURRENT EDITION OF THE NATIONAL ELECTRICAL CODES, NATIONAL FIRE CODES OF THE NATIONAL FIRE PROTECTION ASSOCIATION, THE REQUIREMENTS OF LOCAL UTILITY COMPANIES, AND WITH THE REQUIREMENTS OF ALL GOVERNMENTAL AGENCIES OR DEPARTMENTS HAVING JURISDICTION. IF ANY CONFLICTS OR DISCREPANCIES OCCUR THE MOST STRINGENT
SHALL APPLY.
J. MOUNTING HEIGHTS FOR WALL MOUNTED DEVICES INDICATED ABOVE FINISHED FLOOR ARE TO CENTER OF DEVICE UNO. MOUNTING HEIGHTS TO CEILING SUSPENDED DEVICES ARE TO BOTTOM OF DEVICE UNO. WHERE MOUNTING HEIGHTS ARE NOT INDICATED OR ARE IN CONFLICT WITH ANY OTHER BUILDING SYSTEM, CONTACT THE ENGINEER BEFORE AFFECTING INSTALLATION. REFER ALSO TO ARCHITECTURAL INTERIOR AND EXTERIOR ELEVATIONS, CEILING HEIGHTS AND OTHER DETAILS OF THESE DOCUMENTS, AS APPLICABLE.
K. DO NOT SCALE FROM DRAWINGS, AS PRINTING DISTORTS SCALE. WORK SHALL BE LAID OUT FROM DIMENSIONED
DRAWINGS, OR DIMENSIONS SUPPLIED TO THE CONTRACTOR.
L. REFER TO ARCHITECTURAL WALL ELEVATIONS (WHERE GIVEN) FOR HEIGHTS AND MOUNTING RELATIONSHIP OF OUTLETS AND FURNITURE, CASEWORK, AND/OR EQUIPMENT. ADDITIONAL OUTLETS MAY BE SHOWN ON
ARCHITECTURAL DRAWINGS AND SHALL BE INCLUDED IN THE CONTRACT.
M. FLUSH OR PEDESTAL TYPE FLOOR OUTLETS/BOXES, AS INDICATED ON PLAN, SHALL BE LOCATED BY DIMENSIONS PROVIDED BY THE ARCHITECT, UNLESS OTHERWISE SHOWN ON PLANS. IF IN DOUBT, CONTACT THE ENGINEER
PRIOR TO ROUGHING-IN ANY WORK.
N. INSTALL EQUIPMENT, MATERIALS, ETC. IN STRICT ACCORDANCE WITH MANUFACTURER’S RECOMMENDATIONS AND DIRECTIONS. IF IN CONFLICT WITH THE DESIGN INDICATED IN CONTRACT DOCUMENTS, ADVISE THE ENGINEER
PRIOR TO INSTALLATION FOR CLARIFICATION.
O. THE CONSTRUCTION MANAGER, GENERAL CONTRACTOR, OR WHOMEVER HOLDS THE PRIME CONTRACT(S) FOR THIS CONSTRUCTION IS RESPONSIBLE FOR THE COORDINATION, APPEARANCE, SCHEDULING AND TIMELINESS OF THE WORK OF ALL TRADES, CONTRACTORS, SUPPLIERS, INSTALLERS, ETC. POOR OR UNTIMELY WORK ON THE PART OF ANY SUBCONTRACTOR SHALL BE RESOLVED BY THE PARTY WHO ENGAGED THEM ON THIS PROJECT.
P. THE PURPOSE AND INTENT OF ALL OF THE DOCUMENTS PERTAINING TO THIS PROJECT IS TO PROVIDE A COMPLETE, FUNCTIONAL, SAFE, LIKE-NEW FACILITY. ANYTHING LESS SHALL BE UNACCEPTABLE.
Q. ALL SYSTEMS, EQUIPMENT AND MATERIALS ARE TO BE INSTALLED IN A NEAT AND WORKMANLIKE MANNER. WORK NOT MEETING THIS CRITERION SHALL BE REMOVED AND REINSTALLED SATISFACTORILY. FINAL DETERMINATION OF
THE ACCEPTABILITY OF THE QUALITY OF WORK RESIDES WITH THE ENGINEER
R. ALL WORK, MATERIALS, EQUIPMENT, ETC. SHALL BE FULLY GUARANTEED FOR ONE FULL CALENDAR YEAR FROM THE DATE OF SUBSTANTIAL COMPLETION AS DOCUMENTED BY THE ENGINEER, UNLESS LONGER WARRANTY
PERIODS FOR EQUIPMENT ARE SPECIFIED.
S. ALL WORK SHALL BE CONCEALED UNLESS SPECIFICALLY INDICATED TO BE EXPOSED, OR REQUIRED TO BE EXPOSED. IF IN DOUBT, CONTACT THE ENGINEER FOR CLARIFICATIONS PRIOR TO INSTALLING ANY SUCH WORK.
T. UNLESS OTHERWISE SPECIFIED OR INDICATED, ALL EQUIPMENT AND/OR MATERIALS WITHIN OCCUPIED SPACES OR EXPOSED TO VIEW ON THE BUILDING EXTERIOR SHALL BE PRIMED AND FINISHED SO AS TO COMPLEMENT ADJACENT SURFACE, UNLESS OTHERWISE NOTED. COORDINATE WORK AND COLORS WITH ARCHITECT.
U. WHERE PENETRATING ROOFING MEMBRANE OR OTHER MATERIALS USED FOR WEATHERPROOFING THE BUILDING, MAKE SUCH PENETRATION IN A WAY THAT WILL NOT VOID OR DIMINISH THE ROOFING WARRANTY OR INTEGRITY IN ANYWAY. COORDINATE ALL SUCH PENETRATIONS WITH THE ROOFING MANUFACTURER AND ARCHITECT.
V. CEILING-MOUNTED ELECTRICAL DEVICES SHALL BE CENTERED IN 2'X2' CEILING TILE AND INSTALLED CENTERED ON
2' DIMENSION OF 2'X4' TILE AND ON CENTERLINE OR A QUARTER POINT ON 4' DIMENSION.
W. PROVIDE DETAILED SHOP DRAWINGS TO ENGINEER PRIOR TO PURCHASING OR INSTALLING ANY EQUIPMENT DEVIATIONS IN SIZES, CAPACITIES, FIT, FINISH, ETC. FOR EQUIPMENT FROM THAT PRIME SPECIFIED SHALL BE THE RESPONSIBILITY OF THE PURCHASER OF THAT EQUIPMENT. ANY PROVISIONS REQUIRED TO ACCOMMODATE A DEVIATION, WHETHER APPROVED BY THE ENGINEER OR NOT, SHALL BE THE RESPONSIBILITY OF THE PURCHASER.
X. WHERE FIRE-RATED CEILING ASSEMBLIES ARE NOTED, PROVIDE UL-LISTED FIRE-RATED GYPSUM BOARD OR PRE- MANUFACTURED ENCLOSURES ABOVE LUMINAIRES, CEILING DEVICES, ETC. IN OR ON CEILING, AS REQUIRED TO
MAINTAIN CEILING RATINGS.
Y. DO NOT RECESS PANELBOARD TUBS OR OTHER FLUSH-MOUNTED EQUIPMENT IN WALLS THAT HAVE A FIRE
RATING. NO INSTALLATION SHALL DIMINISH OR VOID FIRE RESISTIVE RATINGS IN ANYWAY.
Z. COORDINATE THE LOCATION OF DRAINS, ELECTRICAL OUTLETS, GAS OUTLETS, ETC. WITH ALL CASEWORK, KITCHEN EQUIPMENT, MECHANICAL ROOM EQUIPMENT, ETC. PRIOR TO COMMENCING INSTALLATION. WORK NOT SO COORDINATED SHALL BE REMOVED AND PROPERLY INSTALLED AT THE EXPENSE OF THE RESPONSIBLE
CONTRACTOR(S).
AA. ALL OFFSETS, TURNS, FITTINGS, TRIM, DETAIL, ETC. MAY NOT BE INDICATED, BUT SHALL BE PROVIDED AS REQUIRED. ADDITIONAL ALLOWANCES SHALL BE INCLUDED FOR SAME AT EACH PROPOSER’S DISCRETION.
BB. INSTALL NO PIPING, CONDUIT, DUCTWORK, ETC. IN A LOCATION OR IN A MANNER WHICH WILL ALLOW FREEZING OR
THE COLLECTION OF CONDENSATION THEREON. IF IN DOUBT, CONTACT THE ENGINEER.
CC. ALL WIRING SYSTEMS SHALL BE INSTALLED WITH A MINIMUM OF SPLICES. CONDUCTORS, WHETHER SINGLE OR MULTI-PAIR, SHALL BE INSTALLED CONTINUOUS INSOFAR AS POSSIBLE FROM TERMINAL POINT TO TERMINAL POINT.
DD. NO CONDUIT, SUPPORTS, ETC. SHALL BE RUN THROUGH ACCESS CLEARANCES OF EQUIPMENT BY OTHER TRADES
(I.E. VAV BOXES). COORDINATE WITH ALL TRADES PRIOR TO CONSTRUCTION.
EE. ALL SUPPORTS FOR EQUIPMENT, DEVICES OR…