ADDENDUM 1.pdf
PDF 7 MB Posted
- Attached to
- Fire Training Tower Repair
- Solicitation number
- PC-27-011
- Issued by
- Sacramento County, California
About this file
This Addendum No. 1, issued September 30, 2026, by the Cosumnes Community Services District for the Fire Training Tower Repair project (PC-27-011) located at 10573 E. Stockton Boulevard, Elk Grove, California, modifies the schedule and contract timeline for the fire-damaged structural repair work. The project scope involves replacing damaged metal floor joists and floor decking on two floor levels of the fire training facility. The addendum revises Article 6 and Article 34 regarding time of completion, requiring contractors to submit all material submittals within five working days of the Notice to Proceed, with the District's Engineer of Record providing five working days for review and approval. Contractors must allow ten working days following approval for fabrication and delivery of floor joists and metal floor decking. The addendum permits contractors to commence demolition and other work while submittals are under review, encouraging early commencement and coordination to maximize construction time. Final completion of all work must be achieved no later than January 8, 2027. The original bid date remains unchanged. Drawing modifications referenced in the addendum are clouded for ease of identification and include changes to structural details, joist replacement specifications, and floor panel installation procedures across multiple floor levels.
The addendum provides detailed construction specifications requiring replacement of existing fire-damaged joists to match existing dimensions and material specifications, removal and reinstallation of floor panels, and replacement of warped wall paneling with new galvanized metal panels. All work must comply with the 2025 California Building Code, Title 24, applicable California Fire Code, and local standards. Cold-formed steel framing must conform to ASTM A653 specifications with G60 galvanizing, and all connections must use #10 or #12 self-drilling screws per specifications. The contractor bears responsibility for temporary shoring, bracing, scheduling, and work coordination, with structural observations required when new joist members and decking are installed. The District will remove existing walls, fire system equipment, utility boxes, and conduits prior to construction commencement.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Bid Notice-Fire Training Tower Repair.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
COSUMNES COMMUNITY SERVICES DISTRICT
Capital Projects Division 8820 Elk Grove Blvd.
Elk Grove, CA 95624
Fire Tower Repair
PC-27-011
ADDENDUM NO. 1
Issued September 30, 2026
TO ALL PROSPECTIVE BIDDERS:
All prospective bidders are hereby advised of the following modifications and clarifications:
SPECIFICATION SECTION – INSTRUCTION TO BIDDERS
ARTICLE 6. TIME OF COMPLETION
Remove and replace the entire section as follows:
The Contractor shall submit all required material submittals within five (5) Working Days following issuance of the Notice to Proceed. The Contractor shall coordinate with the District and Engineer of
Record to facilitate timely review and approval of submittals. The District’s Engineer of Record shall have five (5) Working Days to review and approve complete material submittals. The Contractor shall allow ten (10) Working Days following approval of the required material submittals for fabrication and delivery of the floor joists and metal floor decking.
The Contractor shall not delay demolition or other Work that can reasonably proceed while material submittals are under review or materials are being fabricated. The Contractor is encouraged to commence such Work as soon as practicable and shall coordinate and sequence the Work to maximize the available construction time.
Notwithstanding the foregoing schedule milestones, Final Completion shall be achieved no later than January 8, 2027.
ARTICLE 34. TIME OF COMPLETION
DELETE the following language in its entirety:
Work shall be commenced within ten (10) Working Days of the date stated in the District’s Notice to
Proceed and shall be completed by Contractor in 20 working days as specified in the Contract
Documents.
REPLACE with the following :
Work shall be completed in accordance with Article 6. TIME OF COMPLETION.”
All remaining provisions of Article 34. TIME OF COMPLETION remain unchanged and in full force and effect.
DRAWING – VARIOUS MODIFICATIONS
• Refer to the Addendum No. 1 drawing, which modifies various items of work. All revisions are clouded on the drawings for ease of identification.
THE ORIGINAL BID DATE HAS NOT CHANGED.
SHEET INDEX
CCSD FIRE TOWER REPAIR
PROJECT DATA
PROJECT CONTACTS
PROJECT USE/SCOPE
OCCUPANCY U
30' (100' ALLOWED)
SCOPE OF WORK
REPLACE EXISTING FIRE DAMAGED STRUCTURAL ELEMENTS WITH SIMILAR
STRUCTURAL ELEMENTS
BUILDING CODE NOTES
1. HAZARDOUS MATERIALS IN ANY QUANTITY SHALL CONFORM TO
SECTIONS 307 & 414 OF THE 2015 CBC & CURRENT EDITION OF THE
CALIFORNIA FIRE CODE.
THIS PROJECT SHALL COMPLY WITH THE REQUIREMENTS OF TITLE-24, THE 2025
C.B.C., C.M.C., C.P.C., C.E.C., N.E.C., & CALIFORNIA FIRE CODE. THIS PROJECT
SHALL ALSO COMPLY WITH THE CALIFORNIA GREEN BUILDING STANDARDS CODE
AS APPLICABLE AND THE LATEST CALIFORNIA AMENDMENTS FOR ENERGY &
ACCESSIBILITY AND ALL LOCAL STANDARDS AND ORDINANCES.
COMPLIANCE CODES
FIRE TRAINING FACILITY
OWNER
APN 0134-0220-047
ELK GROVE, CALIFORNIA 95624
ABBREVIATIONS
DESC.ABB.
AB
AC
ADA
BC
BLDG.
BOC
BW
COL
C
C,G, & SW
CL
CB
CO
C.O.S.
CPUC
DIA
DIP
DWG
EC
EL
EP
ESMT
EX.
FL
FF
FOC
FH
FTG
G
GB
GI
HP
HORIZ
INV
LF
L
MAX
MH
MIN
NO.
NTS
P
PC
PP
PT
PUE
PVC
PL
R R/W
RC
RCP
RWL
SD
SS
SL
SW
SDJB
SDMH
SSMH
STA
STD
ST
TC
TI
TW
TYP
U.O.N.
UPRR
V
VAR
VC
VERT
W
WS
(W) (E) (S) (N) (L) (R)
AT
AGGREGATE BASE
ASPHALT CONCRETE
AMERICANS WITH DISABILITIES ACT
BEGINNING OF CURVE
BUILDING
BACK OF CURB
BACK OF WALK
COLUMN
CONCRETE
CURB, GUTTER, AND SIDEWALK
CENTERLINE
CATCH BASIN
CLEANOUT
CITY OF STOCKTON
DIAMETER
DUCTILE IRON PIPE
DRAWING
END OF CURVE
ELEVATION
EXISTING PAVEMENT
EASEMENT
EXISTING
FLOWLINE
FINISHED FLOOR
FACE OF CURB
FIRE HYDRANT
FOOTING
GROUND
GRADE BREAK
HORIZONTAL
INVERT
LINEAL FEET
LEFT
MAXIMUM
MAINTENANCE HOLE
MINIMUM
NUMBER
NOT TO SCALE
PAVEMENT
POINT OF CURVATURE
POWER POLE
POINT
PUBLIC UTILITY EASEMENT
POLYVINYL CHLORIDE
PROPERTY LINE
RADIAL OR RADIUS
RIGHT-OF-WAY
ROLL-CURB
REINFORCED CONCRETE PIPE
RAIN WATER LEADER
STORM DRAIN
SANITARY SEWER
STREET LIGHT
SIDEWALK
STORM DRAIN MAINTENANCE HOLE
SANITARY SEWER MAINTENANCE HOLE
STATION
STANDARD
STREET
TOP OF CURB
TRAFFIC INDEX
TOP OF WALL
TYPICAL
UNDERGROUND VAULT
VAR
VERTICAL CURVE
VERTICAL
WATER
WATER SERVICE
WEST
EAST
SOUTH
NORTH
PLUS OR MINUS
LEFT SIDE OF ROAD
RIGHT SIDE OF ROAD
UNLESS OTHERWISE NOTED
HIGH POINT
STORM DRAIN JUNCTION BOX
CALIF. PUBLIC UTILITIES COMMISSION
UNION PACIFIC RAILROAD
GALVANIZED IRON
NO SCALEVICINITY MAP
AVERAGE BUILDING
HEIGHT
10573 E. STOCKTON BLVD.
Siegfried Engineering, Inc.
3428 Brookside Road Stockton, CA 95219
(209) 943-2021
STRUCTURAL ENGINEER CONTACT
Jori Lemmon, S.E., P.E.
COVER SHEET
CS
COSUMNES COMMUNITY
SERVICES DISTRICT
8820 ELK GROVE BLVD.
ELK GROVE, CA 95624
REVISIONS
DateNo. Description
Job No.
Date
Drawn by
Proj Mgr JL
09/25/2026
26051
PROJECT
SHEET TITLE
CCSD FIRE
TOWER REPAIR
10573 E. STOCKTON
BLVD, ELK GROVE, CA
ATL
Sheet:
3428 Brookside Road Stockton,California 95219 209-943-2021 Fax: 209-942-0214 www.siegfriedeng.com
CIVIL
STRUCTURAL
LANDSCAPE
ARCHITECTURE
SURVEYING
PLANNING
ATHLETIC
FACILITY DESIGN
GEOTECHNICAL
1 9/23/26 BID AGENDA 1
PROJECT SITE
GRANT LINE RD.
KAMMERER RD.
CS COVER SHEET
S1.1 GENERAL NOTES
S2.1 FIRST FLOOR FRAMING PLAN
S2.2 SECOND FLOOR FRAMING PLAN
S3.1 DETAILS
GENERAL:
A. ALL WORK SHALL BE IN STRICT ACCORDANCE WITH THE 2025 EDITION OF THE CALIFORNIA
BUILDING CODE AND ITS REFERENCED DESIGN STANDARDS. ALL SPECIFICATIONS, DESIGN
STANDARDS AND CODES SHALL BE THE LATEST APPROVED EDITIONS BY THE
GOVERNMENTAL AGENCY HAVING JURISDICTION OVER THIS PROJECT.
B. NOTES AND DETAILS ON THE STRUCTURAL DRAWINGS SHALL TAKE PRECEDENCE OVER
GENERAL NOTES AND TYPICAL DETAILS. WHERE NO DETAILS ARE SHOWN OR NOTED IN ANY
PART OF THE WORK THE DETAILS FOR OTHER SIMILAR WORK SHALL APPLY.
C. DETAILS SHOWN ON THE STRUCTURAL DRAWINGS SHALL APPLY IN ESTIMATING AND
CONSTRUCTION TO EVERY LIKE CONDITION WHETHER OR NOT THE REFERENCE IS
REPEATED.
D. THE STRUCTURAL DRAWINGS AND DETAILS SHALL NOT BE SCALED. CONTRACTOR SHALL
VERIFY ALL DIMENSIONS PRIOR TO STARTING CONSTRUCTION.
E. NOTIFY THE STRUCTURAL ENGINEER WHEN DRAWINGS BY OTHERS SHOW OPENINGS,
POCKETS, ETC. NOT SHOWN ON THE STRUCTURAL DRAWINGS, BUT WHICH ARE LOCATED IN
THE STRUCTURAL MEMBERS (BEAMS, COLUMNS, WALLS, SLABS, ETC.).
F. DIMENSIONS SHOWN SHALL TAKE PRECEDENCE OVER SCALE ON PLANS AND DETAILS, ANY
DISCREPANCIES SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE STRUCTURAL
ENGINEER.
G. SITE CONDITIONS THAT ARE NOT REFLECTED ON THE STRUCTURAL DRAWINGS OR THAT
DEVIATE FROM THE MAXIMUM OR MINIMUM DIMENSIONS INDICATED SHALL BE BROUGHT TO
THE ATTENTION OF THE STRUCTURAL ENGINEER IN A TIMELY MANNER. SUCH CONDITIONS
MAY INCLUDE CONFLICT IN GRADES, ADVERSE SOIL CONDITIONS, GROUND WATER PRESENT,
DEEPENED FOOTINGS, UNCOVERED AND UNEXPECTED UTILITY LINES, ETC.
H. THE REVIEW OF SHOP DRAWINGS BY THE STRUCTURAL ENGINEER IS FOR GENERAL
COMPLIANCE WITH THE DRAWINGS AND SPECIFICATIONS.
I. ALL DETAIL CHANGES DESIRED SHALL BE SUBMITTED TO THE STRUCTURAL ENGINEER IN
WRITING. SHOP DRAWINGS DO NOT CONSTITUTE CHANGES IN WRITING. THE APPROVING
GOVERNMENT AGENCY MAY REQUIRE APPROVAL OF THE FIELD CHANGE PROPOSED PRIOR
TO CONSTRUCTION.
J. THE RESPONSIBILITY FOR REVIEW AND COORDINATION OF DRAWINGS AND SPECIFICATIONS
PRIOR TO THE START OF RELATED CONSTRUCTION SHALL BEAR ON THE CONTRACTOR.
DISCREPANCIES THAT EXIST SHALL BE BROUGHT TO THE ATTENTION OF THE STRUCTURAL
ENGINEER IN A TIMELY MANNER, PRIOR TO START OF RELATED CONSTRUCTION.
K. LOADS TO THE BUILDING THAT EXCEED THE LOADS INDICATED IN THE STRUCTURAL
DRAWINGS, OR ANY LOADS EXCEEDING 400 POUNDS THAT ARE NOT INDICATED ON THE
STRUCTURAL DRAWINGS SHALL BE REPORTED TO THE STRUCTURAL ENGINEER.
L. CONSTRUCTION/BUILDING MATERIALS SHALL BE SPREAD OUT IF PLACED ON THE
STRUCTURE, THE MATERIAL LOADS SHALL NOT EXCEED THE DESIGN LIVE LOAD INDICATED.
WHERE THE STRUCTURE HAS NOT ATTAINED FINAL DESIGN STRENGTH OR SUFFICIENT
STABILITY ADEQUATE SHORING AND OR BRACING SHALL BE INSTALLED TO TEMPORARILY
SUPPORT THE MATERIALS.
M. THE STRUCTURAL DRAWINGS SHOW THE REQUIREMENTS FOR THE COMPLETED STRUCTURE
ONLY. TEMPORARY WORKS REQUIRED TO COMPLETE THE CONSTRUCTION PROCESS SHALL
BE THE RESPONSIBILITY OF THE CONTRACTOR.
N. DEVIATIONS FROM EXISTING CONDITIONS WHERE INDICATED ON THE STRUCTURAL
DRAWINGS SHALL BE RESOLVED WITH THE STRUCTURAL ENGINEER PRIOR TO PROCEEDING
WITH DEMOLITION WORK OR NEW CONSTRUCTION.
O. THE RESPONSIBILITY FOR NECESSARY SHORING OR BRACING OF THE STRUCTURE DURING
CONSTRUCTION OR DEMOLITION SHALL BEAR ON THE CONTRACTOR. THESE STRUCTURAL
DRAWINGS DO NOT INDICATE THE PHASING OF WORK. THE RESPONSIBILITY FOR
SCHEDULING AND COORDINATION OF THE WORK SHALL BEAR ON THE CONTRACTOR.
DESIGN DATA:
A. LIVE LOADS:
ROOF LIVE LOAD(U): 20 PSF (RR)
ROOF MECHANICAL AREA (U) 100 PSF (NR)
CORRIDORS, EXITS AND STAIRS(U): 100 PSF (NR)
(NR) = NON-REDUCIBLE LIVE LOAD
(RF) = REDUCIBLE PER CBC 1607.10.1 FOR FLOORS
(RR) = REDUCIBLE PER CBC 1607.12.2 FOR ROOFS
(U) = UNIFORM DISTRIBUTION
(C) = CONCENTRATED OVER 30 IN X 30 IN AREA UNO
STRUCTURAL OBSERVATIONS:
NOTIFY THE STRUCTURAL ENGINEER WHEN DESIGNATED PORTIONS OF THE WORK ARE
READY FOR OBSERVATION.
1. NEW JOIST MEMBERS ARE INSTALLED.
2. NEW DECKING HAS BEEN INSTALLED.
COLD-FORMED STEEL FRAMING
A. COLD-FORMED STEEL FRAMING SHALL BE FROM A STEEL STUD
MANUFACTURERS ASSOCIATION (SSMA) APPROVED SUPPLIER
AND CONFORM TO ICC ESR-3064P.
B. COLD-FORMED STEEL FRAMING SHALL BE GALVANIZED (G60)
AND CONFORM TO ASTM A653 AS FOLLOWS:
1) STUDS AND TRACK - 43 MIL (18GA) & LIGHTER (GRADE 33)
2) STUDS AND TRACK - 54 MIL (16GA) & HEAVIER (GRADE 50)
3) CLIPS AND ANGLES - ALL GAUGES (GRADE 33)
C. COLD-FORMED STEEL FRAMING SHALL BE FABRICATED AND
ERECTED IN ACCORDANCE WITH THE LATEST EDITION OF THE
AISI SPECIFICATION FOR DESIGN OF COLD-FORMED STEEL
STRUCTURAL MEMBERS. STUD MEMBERS SHALL HAVE
PUNCHED WEBS.
D. TOP AND BOTTOM TRACKS SHALL BE 54 MIL (16 GA) WITH 1 1 / 4
INCH FLANGES MINIMUM, UNO.
E. FULL HEIGHT DOUBLE STUDS SHALL BE PROVIDED AT THE
ENDS OF PARTITIONS, AT ALL WALL OPENINGS, AND AT OTHER
LOCATIONS SHOWN ON THE PLANS.
F. FLOOR AND CEILING JOISTS SHALL HAVE THE SAME ON
CENTER SPACING AS THE WALL STUDS, AND THE JOISTS
SHALL BE ALIGNED DIRECTLY OVER THE STUDS SO AS TO
AVOID BENDING IN THE WALL TOP TRACK.
G. FASTENINGS OF COLD-FORMED COMPONENTS SHALL BE WITH
#10 SCREWS UNO PER (ER-4943P) OR EQUAL. MINIMUM
SPACING SHALL BE 1.5 INCHES ON CENTER, AND MINIMUM
EDGE DISTANCE 0.5 INCH.
H. SHEATHING SHALL BE ATTACHED TO BOTH FACES OF METAL
WALL STUDS THROUGHOUT THEIR LENGTH. PROVIDE
BLOCKING/BRIDGING OR LATERAL BRACING ON EACH FACE
WHERE SHEATHING DOES NOT OCCUR.
I. COLD-FORMED FRAMING SHALL BE DESIGN-BUILD WHERE NOT
SPECIFICALLY SHOWN ON THE STRUCTURAL DRAWINGS.
DESIGN-BUILD FRAMING SHALL COMPLY WITH ANY TYPICAL
FRAMING DETAILS PROVIDED.
J. CONNECTIONS TO THE STRUCTURE SHALL INCLUDE
STABILIZING ELEMENTS SUCH AS BRACES, STIFFENER PLATES,
ETC SO AS TO NOT IMPOSE ECCENTRIC LOADING, TWISTING,
OR WARPING TO BUILDING STRUCTURAL MEMBERS. PROVIDE
MATERIAL AND INSTALL STABILIZING ELEMENTS AT NO
ADDITIONAL COST TO THE OWNER.
GENERAL NOTES
S1.1
REVISIONS
DateNo. Description
Job No.
Date
Drawn by
Proj Mgr JL
09/25/2026
26051
PROJECT
SHEET TITLE
CCSD FIRE
TOWER REPAIR
10573 E. STOCKTON
BLVD, ELK GROVE, CA
ATL
Sheet:
3428 Brookside Road Stockton,California 95219 209-943-2021 Fax: 209-942-0214 www.siegfriedeng.com
CIVIL
STRUCTURAL
LANDSCAPE
ARCHITECTURE
SURVEYING
PLANNING
ATHLETIC
ABBREVIATIONS:
ANCHOR BOLT
ADDITIONAL
ADJACENT
ABOVE FINISH FLOOR
AMERICAN CONCRETE INST.
AMERICAN INSTITUTE OF STEEL CONST.
AMERICAN IRON AND STEEL INST.
AMERICAN NATIONAL STANDARDS INST.
AMERICAN WELDING SOCIETY.
ARCHITECTURAL
BELOW FINISH FLOOR
BLOCKING
BOUNDARY NAILING
BOTTOM OF STEEL
CANTILEVERED
CENTER TO CENTER
CAST IN PLACE
CONCRETE BONDING AGENT
CONTROL JOINT
COMPLETE JOINT PENETRATION WELD
CENTER LINE
CEILING
CLEAR
CONCRETE MASONRY UNIT COLUMN
COLUMN
CONNECTION
CONCRETE
CONSTRUCTION
CONTINUOUS
DETAIL
DOUGLAS FIR
DIAGONAL
DIMENSION
DIAMETER
DITTO, OR DO OVER (REPEAT)
DRAWINGS
EXISTING
EACH
EACH FACE
ELEVATION
EXPANSION JOINT
EMBEDMENT
EDGE NAILING
EQUAL
EQUIPMENT
EDGE SCREWS
EACH WAY
FOUNDATION
FINISH FLOOR
FIELD NAILING
FULL PENETRATION WELD
FEET
FOOTING
FAR SIDE
GAGE OR GAUGE
GALVANIZED
GLUE LAM. BEAM
HEADED CONCRETE ANCHOR
HEADER
HOLDOWN
HORIZONTAL
INSTITUTE
KIPS
KNOCK OUT
KNOCK OUT PANEL
KIPS PER SQUARE INCH
LAMINATED
LATERAL FORCE RESISTING SYSTEM
A.B.
ADD'L
ADJ.
A.F.F (OR AFF)
ACI
AISC
AISI
ANSI
AWS
ARCH'L
B.F.F. (OR BFF)
BLKG.
B.N. (OR BN)
B.O.S. (OR BOS)
CANT'L
CC
C.I.P. (OR CIP)
C.B.A.
C.J. (OR CJ)
CJP
C L (OR )
CLG.
CLR.
C.M.U. (OR CMU)
COL.
CONN (OR CONX)
CONC.
CONST.
CONT.
DET
DF
DIAG
DIMS (OR DIM)
DIA., Ø
D.O. (OR DO)
DWGS.
(E)
EA. (OR EA)
E.F. (OR EF)
ELEV
EJ
EMBED
E.N. (OR EN)
EQ. (OR EQ)
EQUIP
E.S. (OR ES)
E.W. (OR EW)
FND., FDN.
FIN. FL. (OR FF)
F.N.
F.P.
FT
FTG
FS
GA
GALV.
GLB
HCA
HDR
HD
HORIZ.
INST.
K
KO
KOP
KSI
LAM.
LFRS
LONG LEG VERTICAL
LONG LEG BACK TO BACK
LONG LEG HORIZONTAL
LONGITUDINAL
LONG SLOTTED HOLE
LAM. STRAND LUMBER (TIMBERSTRAND LSL)
LAM. VENEER LUMBER (MICROLLAM LVL)
MANUFACTURE
MAXIMUM
MACHINE BOLT
MECHANICAL
MECH'L, ELECT. PLUMB.
MINIMUM
NEAR FACE
NEAR SIDE
NOMINAL
NOT TO SCALE
NUMBER
ON CENTER
OPPOSITE
OUTSIDE DIAMETER
POWDER-ACTUATED FASTENER
POUNDS PER CUBIC FOOT
POUNDS PER SQUARE FOOT
POUNDS PER SQUARE INCH
PARTIAL JOINT PENETRATION WELD
PLATE
PLYWOOD
PARALLEL STRAND LUMBER (PARALLAM PSL)
POST TENSIONED
PRESSURE-TREATED DF
PRESSURE-TREATED HEM-FIR
REINFORCING, REINFORCED, REINFORCING
REQUIRED
SCHEDULE
SELF-DRILLING SCREW
SECTION
SHEET
SHEATHING
SIMILAR
SMOOTH, GREASED DOWEL
STEEL JOIST INSTITUTE
SHEET METAL SCREWS STANDARD
STANDARD
STRUCTURAL
SELF TAPPING SCREW
SYMMETRIC
TENSION-CONTROL (BOLTS)
TRUSS JOIST MACMILLAN ("I" JOIST)
TOP AND BOTTOM
TOP OF BEAM
TOP OF CONCRETE
TOP OF FOOTING
TONGUE AND GROOVE
TOP OF PLYWOOD
TOP OF STEEL
TOP OF SLAB
TOP OF WALL
TRANSVERSE
TYPICAL
UNLESS NOTED OTHERWISE VERTICAL
VERTICAL
VERIFY IN FIELD
WITH
WORK POINT
WEAKENED PLANE JOINT
WELDED WIRE FABRIC (REINF.)
L.L.V. (OR LLV)
LLBB
LLH
LONG.
LSH
LSL
LVL
MANUF.
MAX.
M.B. (OR MB)
MECH'L
M.E.P. (OR MEP)
MIN. (OR MIN)
NF
NS
NOM
NTS
NO.
O.C. (OR OC)
OPP
OD
PAF
PCF
PSF
PSI
PJP
PL
PLWD.
PSL
PT
PTDF
PTHF
REINF.
REQ'D (OR REQD)
SCHED.
SDS
SECT
SHT.
SHTG.
SIM.
S.G.D.
S.J.I. (OR SJI)
S.M.S.
STD
STRUCT.
STS
SYM
T.C. (OR TC)
TJI
T/B, T&B T.O.B.
T/CONC
T/FTG
T/G T.O.P.
T.O.S., TOS, T/S
T/SLAB
T.O.W., TOW, T/W
TRANS
TYP., (OR TYP)
U.N.O (OR UNO)
VERT.
VIF
W/, w/
WP
W.P.J.
W.W.F. (OR WWF)
EXISTING STEEL BEAM EXISTING STEEL BEAM EXISTING STEEL BEAM EXISTING STEEL BEAM
EX
IS
TI
NG
S
TE
EL
B
EA
M
EX
IS
TI
NG
S
TE
EL
B
EA
M
EX
IS
TI
NG
S
TE
EL
B
EA
M
EX
IS
TI
NG
S
TE
EL
B
EA
M
EX
IS
TI
NG
S
TE
EL
B
EA
M
AREA OF CONSTRUCTION
REPLACE DAMAGED JOISTS TO
MATCH EXISTING PER 3/S3.1 AND
2/S2.1
CENTER HALLWAY
WALLS BELOW
(E) 800S250-97 JOIST TYP - V.I.F.
(N) REPLACE FLOOR PANELS
ABOVE FRAMING TO MATCH
EXISTING PER 2/S3.1 WITHIN
AREA OF CONSTRUCTION
FLOOR PANELS TO THE
SOUTH OF THE JOINT MUST
BE REPLACED, AND THE
PANELS TO THE NORTH CAN
BE REUSED
SECOND FLOOR
FRAMING PLAN
S2.1
REVISIONS
DateNo. Description
Job No.
Date
Drawn by
Proj Mgr JL
09/25/2026
26051
PROJECT
SHEET TITLE
CCSD FIRE
TOWER REPAIR
10573 E. STOCKTON
BLVD, ELK GROVE, CA
ATL
Sheet:
3428 Brookside Road Stockton,California 95219 209-943-2021 Fax: 209-942-0214 www.siegfriedeng.com
CIVIL
STRUCTURAL
LANDSCAPE
ARCHITECTURE
SURVEYING
PLANNING
ATHLETIC
SECOND FLOOR FRAMING PLAN (LEVEL 1 OVERHEAD)1 3/8"=1'-0"
CONSTRUCTION NOTES:
1. BEGIN JOIST REPLACEMENT ABOVE NORTHEAST WALL OF CENTER HALLWAY.
2. REPLACEMENT SECTION INCLUDES SIX DAMAGED JOISTS CONSTITUTING APPROXIMATELY HALF THE LENGTH OF
THE NORTHEAST ROOM
3. EXISTING JOISTS MAY REMAIN IN PLACE WHERE POSSIBLE DURING REPLACEMENTS, PROVIDED NO INTERFERENCE WITH NEW WORK. NEW JOISTS TO MATCH EXISTING DIMENSIONS AND MATERIAL SPECIFICATIONS.
4. EXISTING WOOD WALLS AROUND NORTHEAST ROOM WILL BE REMOVED BY OWNER PRIOR TO START OF
CONSTRUCTION.
5. IF ADDITIONAL DAMAGE TO ELEMENTS IS NOTED DURING CONSTRUCTION INFORM OWNER AND EOR IMMEDIATELY
FOR FURTHER EVALUATION.
PHOTO OF FIRST REPLACEMENT LOCATION2 NTS
START LOCATION OF JOIST REPLACEMENT
NORTHEAST WALL OF HALLWAY
DIRECTION OF REPLACEMENT
(CONTINUES FOR 6 JOISTS TOTAL)
S3.1
EX
IS
TI
NG
S
TE
EL
B
EA
M
EX
IS
TI
NG
S
TE
EL
B
EA
M
EX
IS
TI
NG
S
TE
EL
B
EA
M
EX
IS
TI
NG
S
TE
EL
B
EA
M
EX
IS
TI
NG
S
TE
EL
B
EA
M
AREA OF CONSTRUCTION
REMOVED DAMAGED JOISTS (7 TOTAL)
AND REPLACE TO MATCH EXISTING
PER 3/S3.1 AND 4/S3.1
REMOVE EXISTING FLOOR
PANELS AS REQUIRED
AND REINSTALL
(E) 1400S250-97 JOIST TYP - V.I.F.
APPROXIMATE LOCATION
OF THIRD FLOOR DECK
OPENING ABOVE LEVEL 2
OVERHEAD BEAMS
REPLACE WARPED WALL PANELING
ALONG THIS WALL. THE EXISTING
MOUNTED EQUIPMENT FOR THE FIRE
SYSTEM WILL BE REMOVED BY THE
OWNER PRIOR TO PROJECT START
THIRD FLOOR
FRAMING PLAN
S2.2
REVISIONS
DateNo. Description
Job No.
Date
Drawn by
Proj Mgr JL
09/25/2026
26051
PROJECT
SHEET TITLE
CCSD FIRE
TOWER REPAIR
10573 E. STOCKTON
BLVD, ELK GROVE, CA
ATL
Sheet:
3428 Brookside Road Stockton,California 95219 209-943-2021 Fax: 209-942-0214 www.siegfriedeng.com
CIVIL
STRUCTURAL
LANDSCAPE
ARCHITECTURE
SURVEYING
PLANNING
ATHLETIC
THIRD FLOOR FRAMING PLAN (LEVEL 2 OVERHEAD)1 3/8"=1'-0"
CONSTRUCTION NOTES:
1. FIRST TWO JOISTS ON SOUTHWEST SIDE TO REMAIN.
2. FIRST FOUR JOISTS ON NORTHEAST SIDE TO REMAIN.
3. EXISTING JOISTS MAY REMAIN IN PLACE WHERE POSSIBLE DURING REPLACEMENTS, PROVIDED NO INTERFERENCE WITH NEW WORK. NEW JOISTS TO MATCH EXISTING DIMENSIONS AND MATERIAL SPECIFICATIONS.
4. IF ADDITIONAL DAMAGE TO ELEMENTS IS NOTED DURING CONSTRUCTION INFORM OWNER AND EOR IMMEDIATELY
FOR FURTHER EVALUATION.
PHOTO OF SECOND FLOOR JOIST CONNECTION2 NTS
(E) JOIST CLIP
FIRST FOUR JOISTS ON N.E. SIDE TO REMAIN
PHOTO OF SECOND FLOOR JOIST CONNECTION3 NTS
FIRST TWO JOISTS ON S.W. SIDE TO REMAIN
S3.1
REMOVE PIPE AND HANGERS AS REQD.
FOR JOIST REPLACEMENT AND REINSTALL
TO MATCH EXISTING CONDITION
WOOD MAZE ON FLOOR ABOVE.
REMOVE AS NEEDED FOR
PROJECT AND DISPOSE
PHOTO OF WALLL PANELING TO BE REPLACED4 NTS
REPLACE EXISTING WARPED
PANEL WITH NEW PBR METAL
PANEL. MATCH EXISTING
GAGE. PANEL TO BE
GALVANIZED
S3.1
UTILIY BOX AND CONDUITS
ON WALL WILL BE REMOVED
BY OWNER PRIOR TO START
OF CONSTRUCTION.
FLOOR PANEL
6" x 1" 18GA.
JOIST
8"x2 1/2" "CEE"
FLOOR PANEL SPLICE
BACK PLATE, 6" x 1" 26GA.
FLOOR PANEL SPLICE PLATE1 NTS
6"
TYP.
FLOOR PANELS
6" x 1" 18GA.
FLOOR JOISTS
8" x 2 1/2" "CEE"
FASTEN FLOOR PANELS TO JOISTS
WITH #12 x 1 1/4" SDS AT 2'-0" O.C.
EA. JOIST
TYPICAL FLOOR PANEL FASTENING DETAIL2 NTS
(N) C-CHANNEL JOIST
TO MATCH EXISTING
L3x3x5.5-68 W/ (6) #12-14 x 1" HEX
HEAD SELF-DRILLING SCREWS
(ASTM C1513) INSTALLED PER
MANUFACTURER'S SPECIFICATIONS
(E) STEEL GIRDER
(N) JOIST TO
MATCH EXISTING
SECTION A
SECTION B
JOIST REPLACEMENT3 NTS
SECOND FLOOR JOIST SPLICE REPLACEMENT4 NTS
CUT DAMAGED BEAM ALONG
CENTERLINE OF (E) CLIP ANGLE
REMOVE EXISTING CLIP AND
CLIP HARDWARE TO ALLOW
FOR SPLICE CONNECTION
INSTALLATION
REMOVE PORTION OF JOIST
SPANNING DAMAGED BAY
14 GAUGE CLIP ANGLE W/ (8) #12-14 x 1" HEX
HEAD SELF-DRILLING SCREWS (ASTM C1513)
ON EACH SIDE OF SPLICE
REPLACE DAMAGED PORTION
TO MATCH EXISTING
PROVIDE (1) 1/2" DIA. ASTM F3125 GRADE
A325 BOLT WITH NUTS AND WASHERS EA
SIDE OF FLANGE
1'-0"
MIN.
0'- 8"
M
IN
4'-0"
2x4 WOOD BLOCKING
SCREW TO CURB
AT 2'-0" O.C.
(E) FLOOR
PANEL
FASTEN HAT CHANNELS TO
FLOOR PANELS WITH
#12 x 3/4" SCREWS AT 1'-0" O.C.
(AROUND ENTIRE PERIMETER)
(E) FLOOR JOIST
DETAILS
S3.1
REVISIONS
DateNo. Description
Job No.
Date
Drawn by
Proj Mgr JL
09/25/2026
26051
PROJECT
SHEET TITLE
CCSD FIRE
TOWER REPAIR
10573 E. STOCKTON
BLVD, ELK GROVE, CA
ATL
Sheet:
3428 Brookside Road Stockton,California 95219 209-943-2021 Fax: 209-942-0214 www.siegfriedeng.com
CIVIL
STRUCTURAL
LANDSCAPE
ARCHITECTURE
SURVEYING
PLANNING
ATHLETIC
PHOTO OF FIRST FLOOR JOIST CONNECTION5 NTS
(E) FLOOR JOIST CLIP
(E) 8002S50-97 JOIST
PHOTO OF SECOND FLOOR PANELS6 NTS
#12 x 1-1/4" SDS
SECTION THRU DRYWALL CURB TO BE REPLACED7 NTS
| Addendum 1- Fire Tower Repair_PC-27-011 |
| Addendum 1_Plans |
| CS COVER SHEET |
| S1.1 GENERAL NOTES |
| S2.1 FIRST FLOOR FRAMING PLAN |
| S2.2 SECOND FLOOR FRAMING PLAN |
| S3.1 DETAILS |
File details come from the government source that posted it. Updated .