ACM.ReedCorners.WholeSite.PDF
PDF 1 MB Posted
- Attached to
- Reed Corners IRA - Roof Replacement
- Solicitation number
- 2139143
- Issued by
- Oneida County, New York
About this file
This is a Pre-Renovation Regulated Building Materials (RBM) Inspection Report prepared by LaBella Associates, D.P.C. for the New York State Office for People with Developmental Disabilities concerning a facility located at 3777 Reed Corners Road in Canandaigua, New York. The inspection was conducted on September 10, 2019, and was designed to identify suspect regulated building materials, including asbestos-containing materials (ACM), lead-based paint (LBP), PCB-containing caulking and glazing compounds, PCB ballasts, and mercury-containing items that may require abatement or removal prior to or during renovation. The inspection encompassed the interior, exterior, and roofing systems of the building expected to be impacted by the proposed renovation project. The work included visual inspection of accessible areas, collection of bulk samples for laboratory analysis, and field testing using X-ray fluorescence (XRF) procedures for lead detection.
The inspection results indicated that no asbestos-containing materials were detected in any of the 29 samples tested across various building materials including cove base mastic, drywall, joint compound, sink linings, linoleum, carpet mastic, ceramic tile grout, caulk, roof shingles, and roof felt. All fluorescent light fixture ballasts examined were labeled "No PCBs," and all painted surfaces tested via XRF procedures were determined to be free of lead-based paint. The inspection was limited to readily accessible materials using hand tools and hand-held power tools, and the report notes that potential exists for additional regulated materials to remain undiscovered in inaccessible or hidden areas. The inspection was conducted in accordance with New York State Code Rule 56-5 requirements and was performed by Ryan Burke under LaBella's New York State Department of Labor Asbestos Handling License Number 29278.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| RFQ.pdf | ||
| CP-FL-H2604-20260911_Roof_Replacement_REED_CORNERS.pdf | ||
| SOW.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
300 State Street, Suite 201 | Rochester, NY 14614 | p 585-454-6110 | f 585-454-3066 www.labellapc.com
Pre- Renovation Regulated Building
Materials Inspection
Location:
3777 Reed Corners Road
Canandaigua, New York 14424
Prepared for:
New York State Office for People with Developmental Disabilities
6666 Babcock Hollow Road
Bath, New York 14810
LaBella Project No. 2192719
September 2019
Table of Contents
Page No.
I. Project Description 1
II. Inspection Procedures 1
III. Inspection Limitations 1
IV. Inspection Results 2
V. Observations & Cautionary Statements 3
Asbestos Bulk Sample Summary Table T-1
Appendix A – Inspection Fact Sheet FS-1
Appendix B – Laboratory Analytical Reports
Appendix C – Asbestos Licenses and Certifications
1 1
I. PROJECT DESCRIPTION
In accordance with current regulations, LaBella Associates, D.P.C. (LaBella) conducted a Pre-
Renovation Regulated Building Materials (RBM) Inspection of the building located at 3777 Reed
Corners Road in the Town of Canandaigua, New York, which is scheduled to be impacted by upcoming renovations.
The objective was to identify suspect RBMs, such as Asbestos-Containing Materials (ACM), Lead-
Based Paint (LBP), PCB-containing caulking and glazing compounds, PCB Ballasts, Mercury-containing items, etc. which may require abatement or removal prior to or during renovation due to applicable regulations. The areas inspected included the interior, exterior and roofing system of the building that are expected to be impacted during this potential renovation project.
II. INSPECTION PROCEDURES
The following procedures were used to obtain the data for this Report:
A. Existing documentation was requested for review. No record drawings or documentation of previously completed inspections were made available.
B. A visual inspection of the interior, exterior and roofing system of the building was conducted to identify visible and accessible sources of the above referenced suspect RBMs.
C. Bulk samples of accessible RBMs were collected and submitted for laboratory analysis.
D. Asbestos samples were submitted for laboratory analysis. Preliminary Polarized Light
Microscopy analyses of non-friable, organically bound (NOB) materials were performed by
LaBella Laboratories, a NYSDOH accredited laboratory, to determine the presence and percentage of asbestos in each sample. Transmission electron microscopy analyses of NOB materials, if necessary, were performed by AMA Laboratories.
E. Suspect painted or glazed materials were spot checked in the field using XRF testing procedures for the presence of lead.
F. Results of the laboratory analyses, field testing and the visual on-site inspection were compiled and summarized.
III. INSPECTION LIMITATIONS
This inspection was conducted in accordance with generally accepted environmental engineering practices for this region. Collection of bulk samples of suspect RBMs was limited to those materials readily accessible using hand tools or hand-held power tools. Homogeneous materials were identified and located based on visual observation from readily accessible points. The data derived from representative samples of any given homogeneous material represent conditions that apply only at that particular location. Inspection protocol and methodology requires that sample data be used to draw conclusions about the entire homogeneous area, but such conclusions may not
2 2 necessarily apply to the general Site as a whole. No sub-surface investigations were performed to determine the possible presence of regulated materials on or in the immediate vicinity of the Site.
No record drawings of the building were available for review as part of this investigation.
LaBella makes no other warranty or representation, either expressed or implied, nor is one intended to be included as part of its services, proposals, contracts or reports. No inspection can wholly eliminate the uncertainty regarding the potential for undiscovered RBMs. The Work performed by
LaBella is intended to reduce, but not eliminate, uncertainty regarding the potential for RBMs at the
Site. This inspection report is not intended to be a bid document for an abatement scope of work.
This report is intended to satisfy the requirements of NYS Code Rule 56-5 for inspections.
Abatement project design can only be performed by a certified Project Designer.
IV. INSPECTION RESULTS
Asbestos-Containing Materials (ACMs) Based on laboratory analyses of bulk samples collected, none of the materials tested were determined to contain asbestos. For a full list of materials sampled, please refer to the Asbestos
Bulk Sample Summary Table.
PCB-Containing Materials Capacitors in Fluorescent Light Fixture Ballasts
Ceiling mounted fluorescent light fixtures were observed throughout the various sections of the building. Older vintage fluorescent light fixtures manufactured prior to 1980 typically contained a capacitor filled with PCB fluid. A representative number of light fixtures were dismantled in each area of investigation, and all had ballasts labeled “No PCBs”. Based on these observations made at the time of the site visit, to the extent feasible, the ballasts within the inspection area can be considered to be non-PCB-containing.
Caulking and Glazing Compounds
It has recently been discovered that certain caulking and glazing compounds have the potential to contain PCBs. Caulking and glazing compounds containing equal to or greater than 50 ppm PCB must be disposed of as PCB-Contaminated hazardous waste. During the inspection, no suspect caulks were observed or submitted to a lab for analysis.
Lead – Based Paint Several representative interior and exterior painted surfaces such as door frames, window frames, piping, etc. were observed and tested for the presence of lead-based paint using XRF testing procedures. All components tested were free of lead.
3 3
V. OBSERVATIONS AND CAUTIONARY STATEMENTS
Potentially Hidden/Inaccessible RBMs
As stated earlier, collection of bulk samples of suspect RBMs was limited to those materials readily accessible. Since the building is occupied and in operation, destructive sampling techniques were employed in a limited fashion in order to minimize disruption to business operations and damage to building components. Although this inspection was conducted in a manner consistent with recognized professional practices, the potential does exist for additional RBMs to be inaccessible, hidden, and undiscovered in the area inspected.
J:\NYS Office for People Dev. Disabilities\2192719 - 3777 Reed Corners Rd RBM\Reports\2192719 - 3777 Reed Corners Rd RBM.doc
Asbestos Bulk Sample
Summary Table(s)
Asbestos Bulk Sample Summary Table
Pre-Renovation Regulated Building Materials Inspection
3777 Reed Corners Road, Canandaigua, New York
No Asbestos Detected in Any of the Materials Tested
T-1 Pre-Renovation Regulated Building Materials Inspection
3777 Reed Corners Road, Canandaigua, New York 14424
LaBella Project 2192719
Sample #
Type of Material
Sample Location
Results %
Asbestos
1A Tan Cove Base Mastic Dining Room None Detected
1B Tan Cove Base Mastic Dining Room None Detected
2A Gray Drywall Dining Room None Detected
2B Gray Drywall Corridor 124 None Detected
3A White Joint Compound Dining Room None Detected
3B White Joint Compound Dining Room None Detected
3C White Joint Compound Corridor 124 None Detected
4A Gray Sink Lining Kitchen None Detected
4B Gray Sink Lining Kitchen None Detected
5A White Sink Lining Kitchen None Detected
5B White Sink Lining Kitchen None Detected
6A Gray Linoleum Dining Room Closet None Detected
6B Gray Linoleum Dining Room Closet None Detected
7A Tan Mastic Dining Room Closet None Detected
7B Tan Mastic Dining Room Closet None Detected
8A Gray Linoleum Utility Room None Detected
8B Gray Linoleum Utility Room None Detected
9A Tan Mastic Utility Room None Detected
T-2 Pre-Renovation Regulated Building Materials Inspection
3777 Reed Corners Road, Asbestos
9B Tan Mastic Utility Room None Detected
10A Tan Carpet Mastic Living Room None Detected
10B Tan Carpet Mastic Living Room None Detected
10C Tan Carpet Mastic Living Room None Detected
11A Blue Linoleum Bedroom 131 None Detected
11B Blue Linoleum Bedroom 131 None Detected
12A Tan Mastic Bedroom 131 None Detected
12B Tan Mastic Bedroom 131 None Detected
13A Tan Linoleum Bedroom 128 None Detected
13B Tan Linoleum Bedroom 128 None Detected
14A Tan Mastic Bedroom 128 None Detected
14B Tan Mastic Bedroom 128 None Detected
15A Blue Linoleum Bedroom 125 None Detected
15B Blue Linoleum Bedroom 125 None Detected
16A Gray Mastic Bedroom 125 None Detected
16B Gray Mastic Bedroom 125 None Detected
17A Gray Ceramic Tile Grout Shower 140 None Detected
17B Gray Ceramic Tile Grout Shower 140 None Detected
T-3 Pre-Renovation Regulated Building Materials Inspection
3777 Reed Corners Road, Asbestos
18A Tan Mastic Shower 140 None Detected
18B Tan Mastic Shower 140 None Detected
19A White Linoleum Bedroom 121 None Detected
19B White Linoleum Bedroom 121 None Detected
20A Tan Mastic Bedroom 121 None Detected
20B Tan Mastic Bedroom 121 None Detected
21A Wood Linoleum Corridor 124 None Detected
21B Wood Linoleum Corridor 112 None Detected
22A Tan Mastic Corridor 124 None Detected
22B Tan Mastic Corridor 112 None Detected
23A Purple Linoleum Bedroom 116 None Detected
23B Purple Linoleum Bedroom 116 None Detected
24A Tan Mastic Bedroom 116 None Detected
24B Tan Mastic Bedroom 116 None Detected
25A Gray Caulk Exterior Patio Door None Detected
25B Gray Caulk Exterior Patio Door None Detected
26A Black Roof Shingle Roof None Detected
26B Black Roof Shingle Roof None Detected
T-4 Pre-Renovation Regulated Building Materials Inspection
3777 Reed Corners Road, Asbestos
27A Black Roof Felt Roof None Detected
27B Black Roof Felt Roof None Detected
28A Gray Drywall Garage None Detected
28B Gray Drywall Garage None Detected
29A White Joint Compound Garage None Detected
29B White Joint Compound Garage None Detected
29C White Joint Compound Garage None Detected
Appendix A
Inspection Fact Sheet
FS-1
3777 Reed Corners Road, Inspection Fact Sheet
Name and Address of Building/Structure
3777 Reed Corners Road
Name and Address of Building/Structure Owner
NYS OPDD
6666 Babcock Hollow Road
Bath, New York 14810
Name and Address of Owner’s Agent
LaBella Associates, D.P.C.
300 State Street, Suite 201
Rochester, New York 14614
Name of the Firm & Person Conducting the Inspection
Ryan Burke (NYSDOL Cert. #11-19691)
Date(s) the Inspection Was Conducted
September 10th, 2019
Appendix B
Laboratory Analytical
Reports
XRF LEAD SAMPLING SURVEY
FIELD LOG
Location: 3777 Reed Corners Rd, Canandaigua Date: 9-10-2019
Job No.: 2192719 Sample Shot By: RJB
J:\NYS Office for People Dev. Disabilities\2192719 - 3777 Reed Corners Rd RBM\Reports\XRF SAMPLING SURVEY FIELD SHEET.docx
Reading No. Location (Room) Wall (A, B, C D) &
Structure Substrate Color XRF Result
1 Cal Check
Living Room
Living Room
Living Room
Wall
Ceiling
Wall
Drywall
Drywall
Drywall
White
White
Light Blue
Passed
0.0
0.0
0.0
Living Room
Living Room
Hallway
Bathroom
Wall
Wall Trim
Wall
Floor Tile
Drywall
Wood
Drywall
Ceramic
Dark Blue
Brown
Green
Pink
0.0
0.0
0.0
0.0
Bathroom
Bedroom
Bedroom
Bedroom
Floor Tile
Floor
Door
Door Frame
Ceramic
Linoleum
Wood
Metal
White
Blue
Brown
White
0.0
0.0
0.0
0.0
Bedroom
Bedroom
Bedroom
Family Room
Floor
Floor
Door
Door
Linoleum
Linoleum
Wood
Metal
White
Gray
Brown
White
0.0
0.0
0.0
0.0
Utility Room
Exterior
Exterior
Exterior
Floor
Siding
Door
Window
Ceramic
Vinyl
Metal
Metal
Red
Blue
White
White
0.0
0.0
0.0
0.0
21Cal Check
Appendix C
Licenses and Certifications
New York State – Department of Labor Division of Safety and Health License and Certificate Unit State Campus, Building 12
Albany, NY 12240
ASBESTOS HANDLING LICENSE
Suite 201 300 State Street
Rochester, NY 14614
FILE NUMBER: 99-1172
LICENSE NUMBER: 29278
LICENSE CLASS: RESTRICTED
DATE OF ISSUE: 01/03/2019
EXPIRATION DATE: 01/31/2020
Duly Authorized Representative – Robert Pepe:
This license has been issued in accordance with applicable provisions of Article 30 of the Labor Law of New York State and of the New York State Codes, Rules and Regulations (12 NYCRR Part 56). It is subject to suspension or revocation for a (1) serious violation of state, federal or local laws with regard to the conduct of an asbestos project, or (2) demonstrated lack of responsibility in the conduct of any job involving asbestos or asbestos material.
This license is valid only for the contractor named above and this license or a photocopy must be prominently displayed at the asbestos project worksite. This license verifies that all persons employed by the licensee on an asbestos project in New York State have been issued an Asbestos Certificate, appropriate for the type of work they perform, by the New York State Department of Labor.
Eileen M. Franko, Director SH 432 (8/12) For the Commissioner of Labor
File details come from the government source that posted it. Updated .