Ohio River Islands National Wildlife Refuge Visitor Center Annex at Middle Island
Heating, Ventilation, Air Conditioning Installation Statement of Work
February 10, 2023
Location:
Fish and Wildlife Service, Ohio River Island, 3856 Waverly Road, Williamstown, WV
26187. Middle Island Visitor Center Annex – there is no street address to this location.
From the town of St. Marys, Take George Street across the bridge onto Middle Island and continue about a mile on a gravel road to the building/worksite (one of only two buildings on the Island).
This is a turnkey project to include all required incidental work and materials, such as vapor-proof piping insulation and sealing of wall penetrations.
Work: All work to be performed by WV licensed HVAC and Electrical Tradesman
Furnish and install a ductless mini split HVAC system in the Visitor Center Annex portion of building – approx. 900 sq.ft.
System to consist of condensing unit set on a pad on grade
2 mini split high wall mounted indoor units that are compatible with the condensing unit
Install necessary wiring from panel to condensing unit and to each wall unit
Furnish and install wall mounted thermostat
Furnish and install condensate piping from each indoor wall unit to outside
Nitrogen pressure test the refrigerant linesets, evacuate, and charge system with refrigerant
Perform start-up and check for proper operation
Disconnect and remove two electric hanging heaters and remove wiring to safe disconnect and make safe
Owner will retain electric hanging heaters for future deployment
Minimum Equipment to be furnished: Provide submittals of proposed equipment for review and approval by FWS before ordering equipment
3 ton mini split condensing unit. 36 MBH cooling, 30.36 MBH heating @7 degrees outdoor. Heat pump, 208-230/1ph
2 – 1.5 ton mini split high wall mounted indoor units. 208-230/1ph
Ohio River Islands National Wildlife Refuge Visitor Center Annex at Middle Island
Heating, Ventilation, Air Conditioning Installation Statement of Work
Condensing unit pad
Wiring
Thermostat
Condensate piping