Copyright 2017 by The American Institute of Architects (AIA)

Exclusively published and distributed by AVITRU, LLC for the AIA

SECTION 099113 - EXTERIOR PAINTING

Revise this Section by deleting and inserting text to meet Project-specific requirements.

This Section uses the term "Architect." Change this term to match that used to identify the design professional as defined in the General and Supplementary Conditions.

Verify that Section titles referenced in this Section are correct for this Project's Specifications; Section titles may have changed.

PART 1 - GENERAL

1.1 RELATED DOCUMENTS

Retain or delete this article in all Sections of Project Manual.

A. Statement Of Work (SOW) and general provisions of the Contract, including General and Supplementary Conditions apply to this Section.

1.2 SUMMARY

A. Section includes surface preparation and the application of paint systems on Steel and Wood.

1.3 DEFINITIONS

Retain this article if paints are specified by manufacturers' trade names rather than by MPI paint numbers. Definitions of MPI Gloss Levels below are from "MPI Architectural Painting Specification Manual" (hereafter, "MPI Manual").

Retain terms that remain after this Section has been edited for a project.

A. MPI Gloss Level 1: Not more than five units at 60 degrees and 10 units at 85 degrees, according to ASTM D523.

B. MPI Gloss Level 3: 10 to 25 units at 60 degrees and 10 to 35 units at 85 degrees, according to ASTM D523.

C. MPI Gloss Level 4: 20 to 35 units at 60 degrees and not less than 35 units at 85 degrees, according to ASTM D523.

D. MPI Gloss Level 5: 35 to 70 units at 60 degrees, according to ASTM D523.

E. MPI Gloss Level 6: 70 to 85 units at 60 degrees, according to ASTM D523.

F. MPI Gloss Level 7: More than 85 units at 60 degrees, according to ASTM D523.

1.4 ACTION SUBMITTALS

A. Product Data: For each type of product. Include preparation requirements and application instructions.

See "Writing Guide" Article in the Evaluations for discussion of first subparagraph below.

1. Include printout of current "MPI Approved Products List" for each product category specified, with the proposed product highlighted.

2. Indicate VOC content.

B. Samples for Initial Selection: For each type of topcoat product.

Delete "Samples for Initial Selection" Paragraph above if colors and other characteristics are preselected and specified or scheduled. Retain "Samples for Verification" Paragraph below with or without above.

C. Samples for Verification: For each type of paint system and each color and gloss of topcoat.

Color and gloss of Samples change as they age; seven-day old Samples appear different from freshly dried Samples.

1. Submit Samples on rigid backing, 8 inches square.

2. Apply coats on Samples in steps to show each coat required for system.

3. Label each coat of each Sample.

4. Label each Sample for location and application area.

D. Product List: Cross-reference to paint system and locations of application areas. Include color designations.

1.5 MAINTENANCE MATERIAL SUBMITTALS

A. Furnish extra materials, from the same product run, that match products installed and that are packaged with protective covering for storage and identified with labels describing contents.

If necessary, replace percentage in "Paint" Subparagraph below with a specific number of gallons (liters) or cases and include an expanded description of the quantity of each material and color.

1. Paint: 5gal of each material and color applied.

1.6 QUALITY ASSURANCE

A. Mockups: Apply mockups of each paint system indicated and each color and finish selected to verify preliminary selections made under Sample submittals and to demonstrate aesthetic effects and set quality standards for materials and execution.

1. COR will select one surface to represent surfaces and conditions for application of each paint system.

a. Vertical and Horizontal Surfaces: Provide samples of at least 10 sq. ft.

b. Other Items: COR will designate items or areas required.

2. Final approval of color selections will be based on mockups.

a. If preliminary color selections are not approved, apply additional mockups of additional colors selected by COR at no added cost to BLM (the agency).

3. Approval of mockups does not constitute approval of deviations from the Contract Documents contained in mockups unless COR specifically approves such deviations in writing.

Retain subparagraph below if the intention is to make an exception to the default requirement in Section 014000 "Quality Requirements" for demolishing and removing mockups.

4. Subject to compliance with requirements, approved mockups may become part of the completed Work if undisturbed at time of Substantial Completion.

1.7 DELIVERY, STORAGE, AND HANDLING

A. Store materials not in use in tightly covered containers in well-ventilated areas with ambient temperatures continuously maintained at not less than 45 deg F.

1. Maintain containers in clean condition, free of foreign materials and residue.

2. Remove rags and waste from storage areas daily.

If necessary, insert special requirements for fire protection, heating, ventilation, and other conditions for storage areas on-site.

1.8 FIELD CONDITIONS

A. Apply paints only when temperature of surfaces to be painted and ambient air temperatures are between 50 and 95 deg F.

B. Do not apply paints in snow, rain, fog, or mist; when relative humidity exceeds 85 percent; at temperatures less than 5 deg F above the dew point; or to damp or wet surfaces.

PART 2 - PRODUCTS

Manufacturers and products listed in SpecAgent and Masterworks Paragraph Builder are neither recommended nor endorsed by the AIA or AVITRU. Before inserting names, verify that manufacturers and products listed there comply with requirements retained or revised in descriptions and are both available and suitable for the intended applications. For definitions of terms and requirements for Contractor's product selection, see Section 016000 "Product Requirements."

2.1 MANUFACTURERS

A. Manufacturer: Subject to compliance with requirements, provide products by one of the following or an approved equal:

1. Benjamin Moore &Co.

2. PPG Paints

3. Sherwin-Williams Company (The)

4. In kind stain product for staining ceiling of main entrance area

Retain "Products" Paragraph below and insert lists of manufacturers and products in Exterior Painting Schedule to require specific products or a comparable product from other manufacturers.

See lists of products currently approved by MPI in its "MPI Approved Products Lists." See "Writing Guide" Article in the Evaluations for further discussion.

B. Products: Subject to compliance with requirements listed in the Exterior Painting Schedule for the paint category indicated.

2.2 PAINT, GENERAL

A. MPI Standards: Products shall comply with MPI standards indicated and shall be listed in its "MPI Approved Products Lists."

B. Material Compatibility:

Systems could fail if paints used for individual coats are incompatible. MPI's paint systems match primers and topcoats and take compatibility into consideration.

1. Materials for use within each paint system shall be compatible with one another and substrates indicated, under conditions of service and application as demonstrated by manufacturer, based on testing and field experience.

2. For each coat in a paint system, products shall be recommended in writing by topcoat manufacturers for use in paint system and on substrate indicated.

C. Colors: Match existing colors as practical and approved by COR.

2.3 SOURCE QUALITY CONTROL

Retain this article for large projects or critical coatings where additional control is needed. Delete if tests are not required.

A. Testing of Paint Materials: BLM reserves the right to invoke the following procedure:

1. BLM will engage the services of a qualified testing laboratory or agency to sample paint materials. Contractor will be notified in advance and may be present when samples are taken. If paint materials have already been delivered to Project site, samples may be taken at Project site. Samples will be identified, sealed, and certified by testing laboratory or agency.

2. Qualified testing laboratory or agency will perform tests for compliance with product requirements.

3. BLM may direct Contractor to stop applying paints if test results show materials being used do not comply with product requirements. Contractor shall remove noncomplying paint materials from Project site, pay for testing, and repaint surfaces painted with rejected materials. Contractor will be required to remove rejected materials from previously painted surfaces if, on repainting with complying materials, the two paints are incompatible.

PART 3 - EXECUTION

3.1 EXAMINATION

A. Examine substrates and conditions, with Applicator present, for compliance with requirements for maximum moisture content and other conditions affecting performance of the Work.

B. Maximum Moisture Content of Substrates: When measured with an electronic moisture meter as follows:

Percentages in six subparagraphs below are based on "MPI Manual."

1. Wood: 15 percent.

C. Verify suitability of substrates, including surface conditions and compatibility, with existing finishes and primers.

D. Proceed with coating application only after unsatisfactory conditions have been corrected.

1. Application of coating indicates acceptance of surfaces and conditions.

3.2 PREPARATION

For renovation projects, consult "MPI Maintenance Repainting Manual" and revise first paragraph below and paint systems specified in the Exterior Painting Schedule.

A. Comply with manufacturer's written instructions and recommendations in "MPI Architectural Painting Specification Manual" applicable to substrates and paint systems indicated.

B. Remove hardware, covers, plates, and similar items already in place that are removable and are not to be painted. If removal is impractical or impossible because of size or weight of item, provide surface-applied protection before surface preparation and painting.

1. After completing painting operations, use workers skilled in the trades involved to reinstall items that were removed. Remove surface-applied protection.

C. Clean substrates of substances that could impair bond of paints, including dust, dirt, oil, grease, and incompatible paints and encapsulants. Perform pressure wash to remove dust and dirt as needed.

Coordination of shop-applied prime coats with topcoats is critical.

Retain "Steel Substrates" Paragraph below if steel is not shop primed or if shop primer is removed in the field.

D. Steel Substrates: Remove rust, loose mill scale, and shop primer if any. Clean using methods recommended in writing by paint manufacturer but not less than the following:

Usually retain one of first two subparagraphs below. SSPC-SP 2 and SSPC-SP 3 remove loose rust, mill scale, and paint. SSPC-SP 2 is minimum surface preparation accepted by AISC for painted steel.

1. SSPC-SP 2.

2. SSPC-SP 3.

SSPC-SP 7/NACE No. 4 permits tight residues of rust, mill scale, and coatings to remain. Be aware that blast cleaning methods may not be practical for use at Project site and may not be allowed by authorities having jurisdiction.

3. SSPC-SP 7/NACE No. 4.

SSPC-SP 11 requires complete removal of rust, mill scale, and paint by power tools. SSPC-SP 11 uses nonabrasive methods and is more thorough than SSPC-SP 2, SSPC-SP 3, and SSPC-SP 7/NACE No. 4.

4. SSPC-SP 11.

Retain "Shop-Primed Steel Substrates" Paragraph below if primers are shop applied and are not removed in the field.

E. Shop-Primed Steel Substrates: When applicable for elements of the south side steel canopy and main entrance door frames, clean field welds, bolted connections, and areas where shop paint is abraded. Paint exposed areas with the same material as used for shop priming to comply with SSPC-PA 1 for touching up shop-primed surfaces.

Galvanized-metal substrates should not be chromate passivated if primers are field applied. If galvanized metal is chromate passivated, consult manufacturers for appropriate surface preparation and primers.

F. Wood Substrates:

If necessary, insert requirements for power or pressure washing.

1. Scrape and clean knots. Before applying primer, apply coat of knot sealer recommended in writing by topcoat manufacturer for exterior use in paint system indicated.

2. Sand surfaces that will be exposed to view and dust off.

3. After priming, fill holes and imperfections in the finish surfaces with putty or plastic wood filler. Sand smooth when dried.

3.3 APPLICATION

A. Apply paints according to manufacturer's written instructions and recommendations in "MPI Architectural Painting Specification Manual."

If Project requires restricted application method (e.g., using only spray or rollers), revise first subparagraph below accordingly.

1. Use applicators and techniques suited for paint and substrate indicated.

2. Paint surfaces behind movable items same as similar exposed surfaces.

3. Paint both sides and edges of exterior doors and entire exposed surface of exterior door frames.

Retain first subparagraph below if required for steel windows.

4. Paint entire exposed surface of window frames and sashes.

5. Do not paint over labels of independent testing laboratory or agencies or equipment name, identification, performance rating, or nomenclature plates.

6. Primers specified in painting schedules may be omitted on items that are factory primed or factory finished if acceptable to topcoat manufacturers.

If tinting is not required, delete first paragraph below. Different tints show through as topcoat erodes.

B. If undercoats or other conditions show through topcoat, apply additional coats until cured film has a uniform paint finish, color, and appearance.

C. Apply paints to produce surface films without cloudiness, spotting, holidays, laps, brush marks, roller tracking, runs, sags, ropiness, or other surface imperfections. Cut in sharp lines and color breaks.

3.4 FIELD QUALITY CONTROL

A. Dry Film Thickness Testing: BLM may engage the services of a qualified testing and inspecting laboratory or agency to inspect and test paint for dry film thickness.

1. Contractor shall touch up and restore painted surfaces damaged by testing.

2. If test results show that dry film thickness of applied paint does not comply with paint manufacturer's written recommendations, Contractor shall pay for testing and apply additional coats as needed to provide dry film thickness that complies with paint manufacturer's written recommendations.

3.5 CLEANING AND PROTECTION

A. At end of each workday, remove rubbish, empty cans, rags, and other discarded materials from Project site.

B. After completing paint application, clean spattered surfaces. Remove spattered paints by washing, scraping, or other methods. Do not scratch or damage adjacent finished surfaces.

C. Protect work of other trades against damage from paint application. Correct damage to work of other trades by cleaning, repairing, replacing, and refinishing, as approved by COR, and leave in an undamaged condition.

3.6 EXTERIOR PAINTING SCHEDULE

Paint systems in this article are based on "MPI Manual." For renovation projects, consult "MPI Maintenance Repainting Manual" and revise paint systems accordingly.

A. Steel:

1. Water-Based Light Industrial Coating System [ MPI EXT 5.1B] [MPI EXT 5.1C] [MPI EXT 5.1M] [MPI EXT 5.1N]:

Retain one of five "Prime Coat" subparagraphs below. First corresponds to MPI EXT 5.1B; second and fifth correspond to MPI EXT 5.1C; third corresponds to MPI EXT 5.1M; and fourth corresponds to MPI EXT 5.1N. If retaining fifth, specify primer complying with MPI #79 in Section where substrate is specified.

Retain one of three "Topcoat" subparagraphs below.

a. Topcoat: Light industrial coating, exterior, water based (MPI Gloss Level 3) [, MPI #161].

b. Topcoat: Light industrial coating, exterior, water based, semi-gloss (MPI Gloss Level 5) [, MPI #163].

c. Topcoat: Light industrial coating, exterior, water based, gloss (MPI Gloss Level 6) [, MPI #164].

Galvanized-metal substrates should not be chromate passivated if primer is field applied. If galvanized metal is chromate passivated, consult manufacturers for appropriate surface preparation and primers.

B. Wood Substrates: Wood trim, Doors, Windows, and Wood board siding.

1. Latex over Latex Primer System [ MPI EXT 6.3L]:

Retain one of four "Topcoat" subparagraphs below.

a. Topcoat: Latex, exterior, flat (MPI Gloss Level 1) [, MPI #10].

b. Topcoat: Latex, exterior, low sheen (MPI Gloss Level 3-4) [, MPI #15].

c. Topcoat: Latex, exterior, semi-gloss (MPI Gloss Level 5) [, MPI #11].

d. Topcoat: Latex, exterior, gloss (MPI Gloss Level 6) [, MPI #119].

2. Latex System [ MPI EXT 6.3A]:

Retain one of four "Topcoat" subparagraphs below.

a. Topcoat: Latex, exterior, flat (MPI Gloss Level 1) [, MPI #10].

b. Topcoat: Latex, exterior, low sheen (MPI Gloss Level 3-4) [, MPI #15].

c. Topcoat: Latex, exterior, semi-gloss (MPI Gloss Level 5) [, MPI #11].

d. Topcoat: Latex, exterior, gloss (MPI Gloss Level 6) [, MPI #119].

3. Water-Based Light Industrial Coating System [ MPI EXT 6.3J]:

Retain one of two "Topcoat" subparagraphs below.

a. Topcoat: Light industrial coating, exterior, water based, semi-gloss (MPI Gloss Level 5) [, MPI #163].

b. Topcoat: Light industrial coating, exterior, water based, gloss (MPI Gloss Level 6) [, MPI #164].

C. Wood Substrates: Wood-based panel products.

1. Latex over Latex Primer System [ MPI EXT 6.4K]:

Retain one of four "Topcoat" subparagraphs below.

a. Topcoat: Latex, exterior, flat (MPI Gloss Level 1) [, MPI #10].

b. Topcoat: Latex, exterior, low sheen (MPI Gloss Level 3-4) [, MPI #15].

c. Topcoat: Latex, exterior, semi-gloss (MPI Gloss Level 5) [, MPI #11].

d. Topcoat: Latex, exterior, gloss (MPI Gloss Level 6) [, MPI #119].

2. Latex over Alkyd Primer System [ MPI EXT 6.4G]:

Retain one of four "Topcoat" subparagraphs below.

a. Topcoat: Latex, exterior, flat (MPI Gloss Level 1) [, MPI #10].

b. Topcoat: Latex, exterior, low sheen (MPI Gloss Level 3-4) [, MPI #15].

c. Topcoat: Latex, exterior, semi-gloss (MPI Gloss Level 5) [, MPI #11].

d. Topcoat: Latex, exterior, gloss (MPI Gloss Level 6) [, MPI #119].

END OF SECTION 099113

10/07/2020

EXTERIOR PAINTING

Tonopah Field Office Contract